MC_cable_colors_01.pdf
PDF 188 KB Posted
- Attached to
- FPCM-MCSP-I001145-M001-KR Jacketed wire
- Solicitation number
- 0000040438
- Issued by
- Amador County, Huntington Beach City, California
About this file
This is a product specification document for Southwire Armorlite Type MC Cable with PVC jacket and neutral-per-phase construction, related to a California state and local contract opportunity for jacketed wire (FPCM-MCSP-I001145-M001-KR). The cable is specified in sizes ranging from 12 AWG through 10 AWG in multiple configurations, including 12/2, 12/3, 12/4, 10/2, and 10/3 solid copper conductor options with dedicated white neutral conductors and green grounding conductors. The cable features lightweight aluminum interlocked armor, sunlight-resistant direct burial-rated PVC jacket, and is UL listed for 600 volts with VW-1 rating. Standard reel quantities of 1,000 feet are available with weights ranging from 206 to 370 pounds per reel and overall diameters from 0.639 to 0.768 inches depending on conductor configuration.
The cable meets or exceeds UL 83, UL 1569, UL 1685, Federal Specification A-A59544, and NFPA 70 (National Electrical Code) Article 330 standards. It is classified for use in UL 1, 2, and 3-hour through-penetration firestop systems and is REACH/RoHS-2 compliant. The product is suitable for applications including branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings; installations in wet locations; direct burial applications; hazardous locations (Class I Div. 2, Class II Div. 2, and Class III Div. 1); and cable tray installations. A key cost advantage is that this construction reduces installation costs up to 50 percent compared to traditional pipe and wire methods, and anti-short bushings are not required per NEC and UL standards. Additional cable constructions are available upon request to meet specific project requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 12_-_I-001145_M-001B_RFQ.pdf | ||
| Specs.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
14 AWG through 8 AWG Copper THHN/THWN Insulated Singles. Dedicated Neutral Conductor for Each Phase Conductor. Green Copper THHN Insulated Grounding Conductor.
UL Listed. 600 Volts. Rated VW-1. Lightweight Aluminum Interlocked Armor. Sunlight Resistant, Direct Burial Rated Overall PVC Jacket.
Southwire Armorlite® Type MC Cable –PVC Jacketed Neutral Per Phase is suitable for use as follows:
• Applications affected by harmonics generated from non-linear switching loads, such as computers, variable frequency drives, electrical test equipment, and office equipment.
• Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
• Wet Location rated per NEC 330.10(11)(C)
• Direct burial applications, embedded in concrete, and where exposed to cinder fills, strong chlorides, caustic alkalis, or vapors of chlorine or of hydrochloric acids.
• Fished or embedded in plaster.
• Concealed or exposed installations.
• Compliance with NEC 210.7 for multiple branch circuits.
• Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
• Installation in cable tray and approved raceways.
• Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).
• Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
Southwire Armorlite® Type MC Cable – PVC Jacketed Neutral Per Phase meets or exceeds the following requirements:
• UL 83, UL 1569, UL 1685
• UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
• Federal Specification A-A59544 (formerly J-C-30B)
• NFPA 70 (National Electrical Code), Article 330
• Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems
• Jacketed & Non Jacketed will both pass " UL Test" & "FT4/IEEE 1202" (70,000 Btu/hr) Vertical Cable Tray Flame Test
• REACH/RoHS-2 (Chemical Limit) Compliant
Southwire Armorlite® Type MC Cable – PVC Jacketed Neutral Per Phase is constructed with solid soft-drawn copper Type THHN/THWN phase conductors, a dedicated neutral per phase conductor, and an insulated copper grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is applied over the conductors. Aluminum interlocking armor is applied over the cable assembly. A black sunlight resistant, flame retardant PVC jacket is applied over the armor. Print legend is included on the binder tape as well as the overall PVC jacket.
Armorlite®
Type MC PVC Jacketed Neutral Per Phase
APPLICATIONS
STANDARDS & REFERENCES
CONSTRUCTION
http://www.ul.com/
Armorlite® Type MC – Neutral Per Phase
CONDUCTOR SIZE AND COLORS
GROUNDING SIZE
AND COLOR
STOCK
NUMBER
REEL
(1000’)
WEIGHT
(LBS/1000’)
OVERALL
DIAMETER
(INCHES)
12/2 SOLID (BLACK/RED/)
12/2 SOLID (WHITE-BLACK/WHITE-RED)
12 SOLID (GREEN) 55-62-87-02 206 .639
12/2 SOLID (BLACK/RED/BLUE)
12/3 SOLID (WHITE-BLACK/WHITE-
RED/WHITE-BLUE)
12 SOLID (GREEN) 58-68-74-02 258 .674
12/4 SOLID (BLACK/RED/BLUE/BLACK-
WHITE)
12/4 SOLID (WHITE/WHITE-
BLACK/WHITE-RED/WHITE-BLUE)
12 SOLID (GREEN) 67-57-03-02 317 .747
10/2 SOLID (BLACK/RED/)
10/2 SOLID (WHITE-BLACK/WHITE-RED)
10 SOLID (GREEN) 292 .723
10/3 SOLID (BLACK/RED/BLUE)
10/3 SOLID (WHITE-BLACK/WHITE-
RED/WHITE-BLUE)
10 SOLID (GREEN) 58-68-78-02 370 0.768
Consult NEC 310.15 for ampacities.
Additional constructions available by request.
• A dedicated neutral conductor for each phase conductor for compliance with NEC 210.7.
• Reduces installation costs up to 50% over pipe and wire.
• UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121,W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038.
• Anti-short bushings are not required for use with MC cable per the NEC and UL
FEATURES