This document provides product specifications for mattresses and control units to be supplied to the Omaha Veterans Affairs Medical Center. The specifications reference 64 Agiliti Health/Sizewise NPT4 mattresses with Legacy Max control units to be used on patient floors 5E, 6E, and 7E. Key details of the mattress include copper-infused foam for temperature regulation, a map liner for infection control and extended life, and a weight under 35 pounds for safe handling. The control unit provides advanced skin protection through alternating pressure redistribution to reduce pressure injuries. It has easily secured hoses positioned towards the foot of the bed that are unlikely to break or get tangled. This relates to solicitation number 36C26323Q1195 from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 23 for mattresses on floors 5, 6, and 7 at the facility in Omaha. No further contract details are provided in the document.

View the file

Other files

File Type Posted
36C26323Q1195_1.docx DOCX document
RFQ 36C26323Q1195.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Supply Item Characteristics

Brand Name or Equal to Item: Agiliti Health/Sizewise NPT4 with Legacy Max Control Unit Applicable model/make/catalog number: Mattress: 7770-NPT403584 Legacy Max Control Unit (1-2): 62350027 Quantity: 64 each Location of use: Omaha VAMC, inpatient floors 5E/6E/7E

NPT4

· Pressure redistribution foam support surface

· copper infused foam that helps regulate heat, keeping skin cool. This helps to regulate patient temperature.

· Map (Mattress Asset Protection) liner encases inner contents of mattress enhancing infection control, extends mattress life.

· The mattress without the pump provides state non-powered pressure redistribution.

· Weighs no more than 35 lbs for safe patient handling/preventing staff injury

· Polycarbonate top cover is durable against robust cleaning products and protocols.

· Promotes immersion and envelopment of the patient by providing low friction and shear.

· Top cover also helps to wick away moisture from the skin.

· Can be replaced separately for extreme wear and tear.

Legacy Max Control Unit

· Provides advanced skin protection to reduce pressure injuries by providing head to heel airflow through the top cover (Advanced Microclimate Management.)

· The pump activates the encased air baffles alternately to provide active alternating pressure redistribution which helps reduce and treat pressure injuries.

· The hose assembly is positioned towards the foot of the bed and has a large secure attachment unlikely to break easily.

· Hose assembly is at the appropriate length to prevent external damage, i.e., getting caught on bed frame wheels.