M67001MARINE CORPS FIELD CONTRACTING SYS
ATTN: SGT ALLISON DAVIS
PO BOX 8368
CAMP LEJEUNE NC 28546
MMP10019SSH2074
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83)
Prescribed by GSA
FAR (48 CFR) 53.243
Amendment issued to respond to questions, to change salient characteristics for CLIN 0003 and to extend the solicitation due date. All other terms and conditions remain the same. See summary of changes.
POC: Sergeant Allison C. Davis
910-451-7844 allison.davis@usmc.mil
1. CONTRACT ID CODE PAGE OF PAGES
J 1 3
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 27-Aug-2019
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X M6700119Q1355
X 9B. DATED (SEE ITEM 11)
20-Aug-2019
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE
RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
27-Aug-2019
CODE
M67001MARINE CORPS FIELD CONTRACTING SYS
P.O. BOX 8368 BLDG 1116
CAMP LEJEUNE NC 28547-8368
M67001 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE M67001
FACILITY CODECODE
EMAIL:TEL:
M6700119Q1355
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
SOLICITATION/CONTRACT FORM
The required response date/time has changed from 30-Aug-2019 12:00 PM to 04-Sep-2019 12:00 PM.
SUPPLIES OR SERVICES AND PRICES
CLIN 0003
The CLIN extended description has changed from:
8 Cubic YardsDimensions:Width: 71 inchesDepth: 72 inchesHeight: 83 inches(3) full length runners, 3 inch x 83 inch channel (4.1 pounds per foot) on bottom (width, side to side) complete with Corten A606 full length Foubler
Plates, 6 inch x 83 inch x .130 minimum thickness between the 3 inch channel and the bottom of the dropbottom dumpster. Runners connect at front and back and in the middle on the bottomOpen top sides, back and front 3/16 inch plate. Sides will have sliding doorsBottoms 3/16 with Dempster style hinged dropbottom3inch re-enforched structure channel around top and also to frame up around lift hook. Lift hook 1.5 inch diameter connected in the center/back of dumpter set in at back. Lift hook must be straight across and not curved/bowed.Lift pins 2 inch diameter x 2 inch long with oval shaped end plate 2 inch x 5 inch x 1/2 inch thick mounted on a 4 inch x 24 inch channel rounded solid at the top where the lift pin connects. (2) 6 inch long x 1.25 inch thick flat har to serve as a flange on the inside and outside where the bottom closes against the dumpster 2 inside and 2 outside on each side(2) sliding doors 30 x 30 12 gauge 3/16 door tracts, one on each side with the door opening towards the lift hook side of the dumpster. 3 inch x 83 inch angle iron welded on the very bottom backside just above the hinged for support.Each container needs to be fitted with a modified plate with upgraded 1 inch plate and 1 inch thick brackets as style of containers allow. Upgrade and convert hook assembly to double hook system (1.5 inch thick) to allow for pick up with either dempster style lift system or roll-off cable pull system. All hook plates and support brackets will need to be upgraded to 1 inch plates. The bottom section of the roll off door needs to be reinforced with 7 gauge
(3/16) hot roll steel sheet and 4X6-1/4 inch tubing to help against impact of a heavy load. Upon delivery the service provider shall supply a certificate of authenticity for the A606-4 Corten Doubler plates. Each container will be primed and painted with brown, enamel paint.
To:
-8 Cubic Yards. CHANGED: Dimensions are: Width: 83 inches, Depth: 71 inches, Height: 73 inches -(3) full length runners, 3 inch x 83 inch channel (4.1 pounds per foot) on bottom (width, side to side) complete with Corten A606 full length Double Plates-6 inch x 83 inch x .130 minimum thickness between the 3 inch channel and the bottom of the drop bottom dumpster. -Runners connect at front and back and in the middle on the bottom. -Open top sides, back and front 3/16 inch plate. Sides will have sliding doors. -Bottoms 3/16 with Dempster style hinged drop bottom. -3 inch re-enforched structure channel around top and also to frame up around lift hook. -Lift hook 1.5 inch diameter connected in the center/back of dumpter set in at back. Lift hook must be straight across and not curved/bowed. -Lift pins 2 inch diameter x 2 inch long with oval shaped end plate 2 inch x 5 inch x 1/2 inch thick mounted on a 4 inch x 24 inch channel rounded solid at the top where the lift pin connects. -(2) 6 inch long x 1.25 inch diameter chain brace with supports on each side (on back edge) for dumping. ADDED: 4 inches wide x 20 inches long x 0.25 inch thick flat bar to serve as a flange on the inside and outside where the bottom closes against the dumpster. (2) inside and (2) outside on each side. (2) sliding doors 30 x 30 12 gauge 3/16 door tracts, one on each side with the door opening towards the lift hook side of the dumpster. 3 inch x 83 inch angle iron welded on the very bottom backside just above the hinged for support. Upon delivery the service provider shall supply a certificate of authenticity for the A606-4 Corten Doubler plates. Each container will be primed and painted with brown, enamel
M6700119Q1355 paint.
The following have been added by full text:
QUESTIONS AND ANSWERS
Question 1: Item 0001 – Is Corten steel required for the floor or will an alternate be accepted?
Answer 1: The Corten steel is required. No alternative will be accepted.
Question 2: Item 0002 - Is Corten steel required for the floor or will an alternate be accepted?
Answer 2: The Corten steel is required. No alternative will be accepted.
Qustion 3: Item 0003 - The last two paragraphs of the specification for the 8 CY pertain to the roll off containers.
Will you please strike these from this line item?
Answer 3: Item 0003 specifications have been changed. See summary of changes.
(End of Summary of Changes)