SEE ADDENDUM

(No Collect Calls)

M6700118Q0036 26-Jul-2018

b. TELEPHONE NUMBER

910-451-1256

8. OFFER DUE DATE/LOCAL TIME

02:00 PM 28 Aug 2018

5. SOLICITATION NUMBER 6. SOLICITATION ISSUE DATE

AUTHORIZED FOR LOCAL REPRODUCTION

PREVIOUS EDITION IS NOT USABLE

STANDARD FORM 1449 (REV. 2/2012)

Prescribed by GSA – FAR (48 CFR) 53.212

(TYPE OR PRINT)

(SIGNATURE OF CONTRACTING OFFICER)

ADDENDA X ARE

26. TOTAL AWARD AMOUNT (For Gov t. Use Only )

23.

CODE 10. THIS ACQUISITION IS

SUCH ADDRESS IN OFFER

17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT

BELOW IS CHECKED

TELEPHONE NO.

M67001

9. ISSUED BY

18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a. UNLESS BLOCK

7. FOR SOLICITATION

INFORMATION CALL:

a. NAME

TRACY E. FULKS

2. CONTRACT NO. 3. AWARD/EFFECTIVE DATE 4. ORDER NUMBER

(TYPE OR PRINT)

30b. NAME AND TITLE OF SIGNER 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER

30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a.UNITED STATES OF AMERICA

27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1. 52.212-4. FAR 52.212-3. 52.212-5 ARE ATTACHED.

X

25. ACCOUNTING AND APPROPRIATION DATA

1. REQUISITION NUMBER

20.

ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED.

OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS

M9305118SUSF011

ARE NOT ATTACHED

27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED

(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE

SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:

. YOUR OFFER ON SOLICITATION

28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN

% FOR:SET ASIDE:UNRESTRICTED OR X

SMALL BUSINESSX

17a.CONTRACTOR/ CODE FACILITY

OFFEROR CODE

M67001MARINE CORPS FIELD CONTRACTING SYS

P.O. BOX 8368 BLDG 1116

CAMP LEJEUNE NC 28547-8368

18a. PAYMENT WILL BE MADE BY CODE

RATED ORDER UNDER

DPAS (15 CFR 700)

13a. THIS CONTRACT IS A

13b. RATING

CODE15. DELIVER TO CODE M31000 16. ADMINISTERED BY

12. DISCOUNT TERMS11. DELIVERY FOR FOB DESTINA-

TION UNLESS BLOCK IS

MARKED

SEE SCHEDULE

14. METHOD OF SOLICITATION

RFQ IFB RFPX

FREIGHT TRAFFIC BRANCH

RAUL VAZQUEZ

ATTN: CONTRACT #

ASH STREET BLDG 1118

CAMP LEJEUNE NC 28542-5000

TEL: 910-449-9027 FAX:

FAX:

TEL:

SERVICE-DISABLED

VETERAN-OWNED

SMALL BUSINESS

8(A)

HUBZONE SMALL

BUSINESS

SIZE STANDARD:

NAICS:

339113

OFFER DATED

29. AWARD OF CONTRACT: REF.

DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY

COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND

EMAIL:

TEL:

31c. DATE SIGNED

SEE SCHEDULE

SCHEDULE OF SUPPLIES/ SERVICESITEM NO. QUANTITY UNIT UNIT PRICE AMOUNT

24.22.21.19.

WOMEN-OWNED SMALL BUSINESS (WOSB)

ELIGIBLE UNDER THE WOMEN-OWNED

SMALL BUSINESS PROGRAM

EDWOSB

32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS

(CONTINUED)

PAGE 2 OF53

ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED: ______________________________________________________

32a. QUANTITY IN COLUMN 21 HAS BEEN

RECEIVED INSPECTED

32b. SIGNATURE OF AUTHORIZED GOVERNMENT

REPRESENTATIVE

32c. DATE 32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT

REPRESENTATIVE

32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32f . TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE

37. CHECK NUMBER

FINALPARTIALCOMPLETE

36. PAYMENT35. AMOUNT VERIFIED

CORRECT FOR

34. VOUCHER NUMBER

FINAL

33. SHIP NUMBER

PARTIAL

38. S/R ACCOUNT NUMBER 39. S/R VOUCHER NUMBER 40. PAID BY

41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT

41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE

42a. RECEIVED BY (Print)

42b. RECEIVED AT (Location)

42c. DATE REC'D (YY/MM/DD) 42d. TOTAL CONTAINERS

STANDARD FORM 1449 (REV. 2/2012) BACK

Prescribed by GSA – FAR (48 CFR) 53.212

AUTHORIZED FOR LOCAL REPRODUCTION

PREVIOUS EDITION IS NOT USABLE

SEE SCHEDULE

20.

SCHEDULE OF SUPPLIES/ SERVICES

21.

QUANTITY UNIT

22. 23.

UNIT PRICE

24.

AMOUNT

19.

ITEM NO.

M6700118Q0036

Section SF 1449 - CONTINUATION SHEET

ITEM NO SUPPLIES/SERVICES ESTIMATED

QUANTITY

UNIT UNIT PRICE ESTIMATED AMOUNT

0001 50 Each Structural Turnout Coat

FFP

NFPA 1971 Complaint and meeting the specifications in the Technical

Specifications provided in the solicitation. Brand Name or Equal to Morning Pride, Part Number LTO-741G

Price Includes Custom Features for Camp Lejeune

FOB: Destination

PURCHASE REQUEST NUMBER: M9305118SUSF011

ESTIMATED

NET AMT

UNIT UNIT PRICE ESTIMATED AMOUNT

0002 50 Each Structural Turnout Pant

FFP

NFPA 1971 Complaint and meeting the specifications in the Technical

Part Number LTO-741G.

PURCHASE REQUEST NUMBER: M9305118SUSF011

UNIT UNIT PRICE ESTIMATED AMOUNT

1001 50 Each OPTION Structural Turnout Coat

FFP

NFPA 1971 Complaint and meeting the specifications in the Technical

UNIT UNIT PRICE ESTIMATED AMOUNT

1002 50 Each OPTION Structural Turnout Pant

FFP

NFPA 1971 Complaint and meeting the specifications in the Technical

UNIT UNIT PRICE ESTIMATED AMOUNT

2001 50 Each OPTION Structural Turnout Coat

FFP

NFPA 1971 Complaint and meeting the specifications in the Technical

UNIT UNIT PRICE ESTIMATED AMOUNT

2002 50 Each OPTION Structural Turnout Pant

FFP

NFPA 1971 Complaint and meeting the specifications in the Technical

TECHNICAL SPECIFICATIONS

GENERAL REQUIREMENTS

This specification details design and materials criteria for custom fit structural fire personal protection equipment (PPE), this PPE is designed to afford protection to the upper and lower body, excluding head, hands, feet, against adverse environmental effects during structural firefighting. All materials and construction will meet or exceed the most current edition of National Fire Protection Association (NFPA) 1971 “Standard on Protective Ensembles for Structural Fire

Fighting and Proximity Fire Fighting” and Occupational Safety & Health Association (OSHA).

APPLICABLE DOCUMENTS

The following standards in their active versions on the date of invitation for quote shall form a part of this specification to the extent specified herein.

STANDARD TITLE

ASTM D 6193-97 Standard Practice for Stitches and Seams

NFPA 1500, Latest Edition Standard on Fire Department Occupational Safety and Health Program

NFPA 1851, Latest Edition Standard on Selection, Care, and Maintenance of Structural Fire Fighting

Protective Ensembles

NFPA 1971, Latest Edition Standard on Protective Ensemble for Structural Fire Fighting

1.0 PURPOSE AND SCOPE

This specification defines the minimum requirements for structural firefighter personal protective equipment (PPE) providing limited protection as defined by NFPA 1971, Standard on Protective Ensemble for Structural Fire

Fighting, Latest Edition. In the absence of comment on a particular point, industry standard practice shall be presumed to prevail. Every exception to specifications shall be clearly spelled out at the time of quote.

2.0 UNITS OF MEASURE

Current NFPA standards applicable to this product specification express values for measurement requirements in SI

(metric-based) units, followed by US (inch-pound) approximate equivalents in parentheses. For the convenience of the fire department, this product specification reverses the order and presents the more familiar US approximation first, followed by the SI requirement in parentheses.

3.0 CERTIFICATION

The manufacturer shall certify that the garments proposed in its quote meet or exceed all requirements of NFPA

1971. The manufacturer shall also list and label this product with Underwriters Laboratories Inc. (UL) or Safety

Equipment Institute (SEI), as the third party certification organization prescribed in NFPA 1971. All certification testing and test preconditioning shall have been performed by an ISO 17025-certified laboratory. UL, SEI or a UL

Authorized Client Test Data Program laboratory will fulfill this requirement.

The manufacturer shall be registered to ISO 9001, Quality Management Systems – Requirements, 2000.

4.0 WARRANTY

The manufacturer shall provide a lifetime warranty against defects in materials and workmanship

5.0 PRODUCT COUNTRY OF ORIGIN

For liability reasons, garments shall be manufactured in the United States of America or Canada by companies with their assets and incorporation within the United States of America or Canada.

6.0 LABELING REQUIREMENTS

Labels shall be permanently and integrally printed onto materials that meet all the requirements for labels of NFPA

1971. The garment shall be clearly labeled to fully identify the material content of all three layers: outer shell, moisture barrier and thermal liner.

In addition, each separable outer shell component shall be labeled in an obvious location including the size, date of manufacturer and an individualized serial number and bar code that matches the corresponding garment liner.

Appropriate warning label(s) shall be permanently affixed to each garment. Additionally, the label(s) shall include the following information.

7.0 CARE INSTRUCTIONS

The manufacturer shall provide a user information guide for the garments, which complies with user information requirements of NFPA 1971. Topics shall include, but not necessarily be limited to: pre-use information, preparation for use, inspection frequency and details, don/doff, use consistent with NFPA 1500, maintenance and cleaning, and retirement and disposal criteria and considerations.

This document shall be packaged with each garment along with a specification summary sheet describing garment custom options, sizing and production details. This written information shall be in complete compliance with NFPA

1971 requirements, and shall reference same.

8.0 TRACEABILITY PROGRAM

The manufacturer shall have in place a computer maintained traceability program that provides for the assignment of a production control number to each garment. The traceability program shall be capable of tracing the garment through production, from the bolts of cloth used in all three layers of the garment composite construction, to the assignment of the garment to the individual firefighter. This production control number shall be visibly located on the garment label and on other protected areas of garment.

9.0 PATENT CONSIDERATIONS

The quoter, without exception, shall indemnify and save harmless the Purchaser and its employees from liability of any nature and kind, including cost and expenses for or on account of any copyrighted, patented or un-patented invention, process, or article manufactured or used in the performance of the contract, including its use by the

Purchaser. If the quoter uses any design, device, or materials covered by letters, patent or copyright, it is mutually agreed and understood without exception that the quote prices shall include all royalties or costs arising from the use of such design, device, or materials in any way involved in the work.

10.0 SIZING

Jackets & trousers will be sized specifically to each fire fighter. Measurements will be obtained conducted by the

Contractor or Contractor Representative based on measurements obtained by physically measuring each fire fighter.

To ensure a perfect fit, sizing shall be determined by actual measurements taken of the firefighter by a trained measurement specialist of the vendor or manufacturer. Sizing measurements shall be taken according to a schedule and location(s) mutually agreed between the manufacturer and the department.

The Contractor or Contractor Representative will also provide a blank form for recording measurements, this Contractors form will be used to place all orders for structural firefighting PPE. Changes in the form format or measuring procedures will be the responsibility of the Contractor to provide training BEFORE any new ordering procedures take place.

Garments shall be available in custom sizing as follows: coat chest in 2-inch (5.1 cm) increments, coat sleeve in

0.5-inch (1.3 cm) increments, coat back length in 1-inch (2.5 cm) increments, pant waist in 2-inch (5.1 cm) increments and pant inseam in 1-inch (2.5 cm) increments. A full range of women’s sizing, on women’s patterns, shall also be available. Each sleeve and inseam length shall provide 100% gradation from shoulder to wrist, and from hip to ankle, to provide proper fit for individual arm and leg lengths. Pattern tailoring to custom-fit neck, bicep, hip/seat and thigh circumferences shall also be provided, when needed, at no additional charge. Neither

Small-Medium-Large-Extra Large sizing nor women’s garments cut to men’s patterning are considered acceptable, since proper fit facilitates mobility and minimizes stress.

11.0 SELF-BINDING

Liner and moisture barrier shall be stitched together and turned, then topstitched, to create a self-binding edge. The extra bulk of separate binding material is specifically prohibited.

12.0 THREAD

All thread used in structural seams shall be Nomex® of minimum Tex size T-70. Light colored garments and trim areas shall feature yellow thread. Black and dark garments shall feature black thread. Tan or bronze colored garments shall feature tan thread.

13.0 STITCH METHODS

13.1 MAJOR A & B SEAMS

Except for the collar Major A seam, which is single-needle lock stitched three times, all Major A & B seams (as defined by NFPA 1971) shall be double stitched, double feld throughout all three layers (outer shell, moisture barrier and thermal liner), and shall be made with Nomex® thread, minimum Tex size T-90. Detailed stitch and seam type requirements are shown below.

Stitch Type 401 Modified Seam Type LSc-2

Double lockstitch, as defined by ASTM D 6193-97 Double feld seam, modified only to ensure that both stitch lines penetrate all layers of cloth at joining, otherwise as defined by

ASTM D 6193-97

Also, all moisture barrier seams shall be tape-sealed to meet all requirements of the NFPA 1971 Liquid Penetration

Resistance Test.

13.2 MINOR SEAMS

Most Minor seams, such as storm shields and mated hems, shall also be stitched with the specified Nomex thread.

Detailed stitch and seam type requirements are shown below.

Stitch Type 301

Lockstitch as defined by ASTM D 6193-97

Seam Type SSae-2

As defined by ASTM D 6193-97, shown

(a) before and (b) after required turning

13.3 POCKETS

Flat garment pockets shall be stitched with the specified Nomex® thread. Detailed stitch and seam type

Stitch Type 301 Seam Type LSd-2

Lockstitch as defined by ASTM D 6193-97 As defined by ASTM D 6193-97

3-Dimensional pocketing shall feature these same construction details, but the reinforced single stitch Seam Type

LSd-1 may be substituted for LSd-2. Detailed seam type requirements are shown below.

Stitch Type 301 Seam Type LSd-1

13.4 TRIM AND DANGER LABELS

Trim and DANGER labels shall be stitched with the specified Nomex® thread. Detailed stitch and seam type

Stitch Type 301 Seam Type SSbd-1

13.5 SINGLE LAYER HEMMING AND FINISHING

Single layer hemming and finishing shall be stitched with the specified Nomex® thread.

Detailed stitch and seam type requirements are shown below.

Stitch Type 301 Seam Type EFb-1

14.0 POCKETS

When exterior pockets are specified, the following requirements shall apply to all such custom option specified exterior pockets:

All pockets and flaps shall be reinforced at the top corners with bar tack stitching.

All pockets shall be reinforced with an extra layer of NFPA-certified outer shell, moisture barrier, or other NFPA-certified reinforcement material for extra durability. The exact location of the reinforcements shall be identified in the custom options section(s).

All pockets shall have a means to drain water and shall have a means of closure.

All pocket closures shall be made either with hook and loop fastener tape a minimum of 1.5 inches (3.8 cm) wide, with a flap, or with snaps. The specific placement of the closure system shall be outlined in the custom options sections.

15.0 TAILORED GRADING OF GARMENT LININGS

All garment layers and Cold Weather Accessory Linings shall be graduated in size to fit within in each other in the overall composite without causing bunching or binding when the garment is worn.

16.0 POINTS OF STRESS

All points of stress shall be reinforced with sturdy bartacks. Rivets are not acceptable because of their potential for rust and electrical or heat conduction.

17.0 ASSET TRACKING SERVICES

The manufacturer shall be capable of providing a web based software to track care, cleaning and maintenance of

PPE. The tracking software will include Inventory Assist and the Hot Spot Locator to help you analyze gaps in your inventory and pinpoint recurring repair problems. Records will be secured in a cloud based environment with 24/7 access.

This tracking program shall meet or exceed all record-keeping requirements of NFPA 1851, Standard on Selection, Care and Maintenance of Structural Fire Fighting Protective Ensembles, Latest Edition. Manufacturer shall have the ability to import records for gear purchased from them, upon request, providing all details required to meet

NFPA 1851, and assist with training to assign all gear while importing.

Labels on each separable part of the garment shall include a standard style interleaved 2 of 5 barcode containing (at a minimum) an individualized serial number for asset tracking purposes.

The manufacturer shall be capable of providing training to department personnel who are involved in the daily use of this tracking program, as well as a built in interactive tutorial.

18.0 REPAIRS AND ALTERATION SUPPORT

The manufacturer shall provide on call at no charge, during normal business hours, a liaison for the repair department to assist the Fire Department on a telephone consultation basis, on all maintenance or repair questions that might arise. Additionally, the manufacturer shall agree to expedite, on its own cost-only basis, all repairs that shall be performed at the manufacturer’s plant, rather than in department, over the life of the contract.

19.0 HIGH TEMPERATURES THERMAL INSULATING MATERIALS REQUIREMENT

Because thermally stable materials are essential to maximizing protective performance in firefighters’ PPE, and because NFPA only states “minimum” performance requirements, all thermal liner or thermal enhancing materials used in the garments shall also meet the following criteria after the 500 degree F oven test:

Material shall remain intact and flexible

No portion of the material shall crack, crumble or flake

20.0 BREATHABILITY REQUIREMENT

Excluding where required by NFPA standard, necessary for functionality, or specifically called out in the custom option sections, all materials fabrics and reinforcements used in the construction of the garments shall be breathable and all moisture barrier material shall be as specified in the Materials Section.

The breathability requirement includes but is not limited to: collar, chinstrap, storm shield, fly, water wells, front coat facings, and reinforcement cushioning where applicable.

Areas where non-breathability is allowed (absent Custom Option specifications): trim or other items placed externally on the arms that might need extra material to pass NFPA required Stored Energy Testing, hook and loop fastening, hardware or hardware backing, and pocket linings where used exterior to the outer shell.

21.0 CONDUCTIVE AND COMPRESSIVE HEAT RESISTANCE (CCHR)

Using breathable materials as outlined in the section titled Breathable Materials, there shall be: A minimum area of

4” x 4” (10.2 cm x 10.2 cm) at the shoulders and elbows that provide a minimum of 25 CCHR at 2 psi. with a minimum 6” x 6” (15.2 cm x 15.2 cm) area at the knees that provide 25 CCHR at 8 psi.

In all three of these compression areas at least a portion of the protective area shall be made from high temperature fiber based materials sewn to the thermal liner on the inside of the liner toward the moisture barrier.

22.0 SEAM PROTECTION AT CUFFS

At the coat and pant cuff Major A seams, the reflective trim shall stop just before the folding of the full feld seam and for additional abrasion protection be covered by a sewn on strip of polymer coated Kevlar material laid on top of the Major A seam and covering each end of the trim.

23.0 COAT SPECIFICATIONS

To avoid liability and interface problems, coats and pants shall be procured from the same manufacturer.

24.0 DESIGN CONCEPT (STYLING)

The standard coat design shall be 6-inches (15.2 cm) longer at the rear hem than at the front hem and provide continuous and unbroken moisture barrier and thermal liner protection from the collar seam to the hem at the bottom of the coat tail. Each coat length shall be determined by each individual’s torso length to provide the coat-to-pant interface as defined by NFPA 1500. Coat design shall interface properly with standard waist high bunker pants. To facilitate various body types the front to rear length differential shall be made available in 3-inch (7.5cm), 4-inch

(10.0cm), 5-inch (12.5cm and 6-inch (15.0cm) “Tail Drops”.

25.0 PATTERNING CONCEPT

Garments shall feature a tailored three-piece body (with one-piece back) and one-piece, set-in sleeve construction throughout the outer shell, moisture barrier and thermal liner layers. Onepiece garment body (either all layers or some layers) will not be considered acceptable since they cannot be tailored to hard-to-fit personnel. Similarly, garments with seams in mid-back are not considered acceptable because of backbone irritation that can occur with

SCBA use. To facilitate individual tailoring needs, the major A & B seams joining the one-piece back to the right and the left front body panels (outer shell and all interior layers) shall be located at the most lateral position when the coat is laid flat for inspection.

26.0 PATTERNING REQUIREMENTS

To assure maximum freedom of movement and reduce kinetic resistance with minimum garment weight and bulk, coat patterning shall include the following features:

Degree of slope on shoulders shall be no more than 20%

Hydraulic Butterfly sleeve patterning having built-in underarm bellow with 85-degree Lift Up

Release Action shall be provided to minimize coat hem rise.

Sleeve attachment shall minimize shoulder lift and allow a full 360 degrees freedom of movement.

Coat hem rise with overhead reach of both arms not to exceed 4-inch (10.2-cm) maximal extension on properly fitted garments.

Shell-and-liner retraction at the cuff shall not exceed 1 inch (2.5 cm) when both arms are raised overhead. This helps eliminate wrist exposure.

10-inch (25.4-cm) chest over-sizing shall be provided.

Coat sweep measurements shall be consistent with the chest over-size at the hem.

Reach when measured from cuff to cuff, with coat lying flat, and standard length sleeves extended to each side, shall be provided as detailed below.

An alteration point at the hem that during manufacture allows the sweep dimension to be adjustable in two-inch (5.0cm) increments

27.0 DRAG RESCUE DEVICE (DRD)

Manufacturer shall supply an NFPA required and certified Drag Rescue Device with each coat. Each strap will be properly labeled with the chest size(s) the Rescue Strap is designed to fit.

Rescue Strap shall be designed in a fashion that it functionally provides a dynamic and articulated action and to eliminate excess strapping material hanging down the back when installed between the garment’s liner and outer shell.

The device shall be constructed using two components: a 1.75” (4.45 cm) Kevlar webbing grab handle; and a free-floating loop of Kevlar rope to go around each of the wearer’s arms/shoulder.

The grab loop shall extend upward and pass through a tunnel of outer shell and pass out through a reinforced slot in the coat outer shell just below the center rear of the collar seam. . The protruding grab loop shall then fold back down and be stored by hook and loop fastener.

The end of the garb loop shall be covered with an outer shell flap sewn below the held in place with hook & loop fastener to reduce the chances of snagging the grab loop by accident.

The Grab Handle shall be constructed of soft and pliable Kevlar webbing meeting the following specifications:

Description 100% Kevlar Double Plain Weave

Chest Size Standard Reach

40 in (101.6 cm) 66 in (167.6 cm)

42 in (106.7 cm) 67 in (170.2 cm)

44 in (111.8 cm) 68 in (172.7 cm)

46 in (116.8 cm) 68 in (172.7 cm)

Width 1.75” (4.45 dm)

Thickness 0.064" ± 0.010" (.163 cm ± .0254 cm)

Tensile 5,000 lb minimum (22.24 kN)

To facilitate comfort and safety the free-floating loop shall be constructed of soft and pliable Kevlar rope meeting the following specifications:

Description 100% Kevlar Tubular Plain Weave - Natural

Width .038” (.097 cm)

Thickness 0.144" ± 0.005" (.366 cm ± .013 cm)

Tensile 3500 lb minimum (15.57 kN)

Rescue Strap shall be sewn with Kevlar thread

28.0 LINER ATTACHMENT

The completed liner-moisture barrier assembly shall attach by means of four (4) evenly spaced glove snaps to each outer shell front facing to reduce weight, bulk and stiffness. To provide continuous moisture and pathogen protection at the front, the liner shall be positioned so it is sandwiched between the coat front facing and a breathable pathogen shield. The use of zippers or hook and loop fasteners in this area is not allowed due to their added weight, bulk and stiffness.

Liner sleeves shall be attached at the cuff by means of snaps on two (2) sets of Nomex tabbing per liner cuff. The male and female snap parts shall both be located on Nomex tabbing that is sewn to the liner at the cuff. A separate piece of Nomex tabbing shall be sewn to the shell cuff and fashioned as a loop without any snap hardware.

To provide continuous moisture protection and pathogen protection at the neck, the liner shall be positioned so that it is sandwiched between an outer-facing pathogen shield and an inside facing of the specified outer shell material.

Attachment at the neck shall be by means of four (4) glove straps that penetrate only the layer of the attachment strip facing towards the liner, so that metal contact at a wearer’s neckline is completely eliminated.

29.0 COAT CERTIFICATION LABEL ON LINER

The coat certification label on the liner shall be affixed to the inside right body panel of the liner in a fashion to provide an inside liner pocket.

30.0 COAT CERTIFICATION LABEL ON SHELL

The coat label on the shell shall be affixed in a conspicuous location once the liner is removed.

31.0 COLLAR

The collar shall be of layered construction, consisting of a layer of waterproof moisture barrier and a layer of NFPA

1971-certified insulating material, sandwiched between two (2) layers of specified outer shell material. NFPA compliant collars shall be at least 3 inches (7.6 cm) high while CGSB compliant collars shall be at least 4 inches

(10.2 cm) high. The design shall incorporate in its patterning a natural contour that will allow proper fit and performance in the standing (upright) or stowed position.

There shall be no vertical or horizontal seams or stitching in the body of the collar. The left outside of the collar shall have a sewn piece of 2-inch x 2-inch (5.0-cm x 5.0-cm) hook fastener tape for chinstrap-to-collar closure. The fastener tape shall be located rear ward far enough to allow for the location of a forward mounted microphone tab if so desired. Each collar shall be graded to individual coat sizes.

32.0 CHIN STRAP

The chinstrap shall be of layered construction identical to that of the collar configuration described in the previous paragraphs. Chinstrap shall be of a crescent shaped design with minimum dimensions of: 9 inches (22.5 cm) long across the top corners, 10.5 inches (26 cm) long across the bottom corners, and 3.5 inches (8.75 cm) in vertical height, measured at the center. The leading underside edge of the chinstrap shall have a 4.0-inch-wide (3.8 cm-wide) horizontal strip of loop fastener tape to ensure an adequately adjustable closure and to ensure passage of the

Whole Garment Liquid Penetration Test.

33.0 HANG-UP LOOP

An 80-pound (36.3 kg) tear strength hang-up loop shall be provided at the interior collar seam. The loop shall be constructed of triple layers of the specified outer shell material, lockstitched to the coat. Webbing is not acceptable.

34.0 SLEEVES

To prevent stove-piping the sleeves shall be individually graded by coat size and sleeve length. For maximum freedom, the sleeve design shall feature extra full cut one-piece set-in sleeves with built-in bellows. To reduce the chances of possible top seam failure in that high thermal exposure area, the sleeve Major seams shall follow the underside of the arm and shall not cross over the outside of the elbow joint. Sleeve seam and sleeve attachment to coat body in all layers shall be 100% double feld and double stitched for maximum.

Easy Move Liner Combo – Torso of coat to be made of TL I (Synergy II 2 Layer) and Sleeves to be made of TL B

(Glide Ice 2 Layer) to allow better movement in the sleeves while donning and doffing the coat.

35.0 INNER WRISTLET & WATERWELL

Every coat shall feature a minimum 4.5-inch (11.4-cm) long, double-layer knit inner wristlets protected by a flame-resistant and moisture-resistant inner waterwell. The inner wristlet shall be sewn to the thermal liner sleeve end (not to the outer shell). The specified moisture barrier shall form an inner waterwell with an elastic gather sewn to the moisture barrier sleeve end.

36.0 EXTERNAL WRISTLET

Every coat shall feature a 2.5-inch (6.4 cm) long knit outer wristlet, which shall be mounted to the end of each outer shell sleeve to prevent liquid and debris movement up the sleeve between the outer shell and the moisture barrier/ thermal liner assembly.

37.0 FRONT CLOSURE PROTECTIVE OVERLAP

Two-inch-wide (5.1 cm-wide) panels of breathable moisture/ pathogen barrier and specified thermal liner materials shall be provided at coat front closure facings to preclude any type of break in the protective envelope. The entire circumference of a closed coat shall consist of specified shell, moisture barrier and thermal liner materials.

An additional layer of breathable moisture/ pathogen barrier material shall be sewn between the 2-inch-wide (5.1 cm-wide) panels and outer shell coat body for the entire length of coat front in a fashion to prevent liquid entry during the NFPA 1971 Whole Garment Liquid Penetration Test.

38.0 COMPOSITE MATERIALS

The specifier has determined the ONLY acceptable combination of materials. Any substitution of materials shall be grounds for immediate disqualification of quote without further consideration.

38.1 OUTER SHELL 38.2

Pioneer - Kevlar/Nomex Blend, 6.6 osy. Twill Weave - Gold

38.2 THERMAL LINING

Synergy II 2 Layer - 7.1 oz. calendared 100% spun 3.3 oz. Meta Aramid facecloth; 1 layer of 2.3 oz. E-89, and one layer 1.5 oz. E-89 (Berry Compliant)

38.3 MOISTURE BARRIER

Stedair 4000 - 3.2 oz/yd2 woven Nomex containing 2% carbon fibers, laminated to a PTFE membrane (Berry

Compliant)

39.0 COAT CUSTOM OPTIONS TO BE PROVIDED

Instructions in this custom options section that contradict earlier specifications or statements supersede those earlier specifications or statements as long as the required certifications are not compromised.

Std -Coat Cuffs

Std -Inspection Port Liner

Std-Liner detachable

Std -SET Thermal Enhancement

Std -Liner Label Pocket

Std-Articulating Rapid Rescue Strap

Std -Take Up Straps o 2 Postman

Std -Trim Double-Stitched

Trim -(4) New York - lime 2-tone Oralite Brilliance (3")

Back Patch -Pioneer - Gold

1 -2" sewn letter -lime Reflexite Brilliance

< CAMP LEJEUNE FIRE >

Hem Patch -Pioneer - Gold

1 -3" sewn letter -lime Reflexite Brilliance o < --NAME- > FF LAST NAME ONLY (1st INITIAL ONLY when specified) o Avg. 7 letters o OK to use 2" letters to fit

Embroidered American Flag o right sleeve

2" Velcro/Zipper Coat Closure

LTO Comfort Chinstrap - Pioneer Gold

Black Knit Material on Comfort Chinstrap

Dead Air Panels Extended

Easy Move Liner Combo o TL I & -TLB

Half Hi Bellows Pockets o Pioneer Gold o 7 x 9 x 1.5 o Place as close to storm shield as possible

Handwarmers behind Bellows Pockets - Fleece

Mic Tab o Pioneer Gold o on shield (stormflap) o 0.5 x 2.5 o Place 4" below top of shield

Large Hook on a Patch w/Velcro Strap -74D - right chest

Multi Height Tool Holder o Arashield Gold o left chest o 10/9 x 4

Sub Wristlets -Long Hybrid with tabs o Nomex o black

To avoid liability and interface problems, coats and pants shall be procured from the same manufacturer.

40.0 PANT SPECIFICATIONS

41.0 DESIGN CONCEPT (STYLING)

The pant shall be of a traditional waist-high-only design to facilitate full torso ventilation of front, rear and sides of trunk for maximum body cooling effect to help minimize firefighter heat stress. For this reason, other than waist-high pants shall not be considered acceptable or “equal,” since additional trunk wrapping traps heat and moisture, increasing heat stress buildup while also creating mechanical resistance when covering the natural torso flexion point of the waist.

42.0 PATTERNING CONCEPT

Garments shall feature a tailored four-piece body plus a one-piece, over-sized crotch diamond pattern in the outer shell, moisture barrier and thermal liner.

43.0 PATTERNING REQUIREMENTS

To assure maximum freedom of movement and reduced kinetic resistance with minimum garment weight and bulk, the pants patterning shall:

Incorporate hydraulic, swivel action leg-to-torso interfaces.

Incorporate an oversized diamond-shaped crotch insert, graded according to size, for maximum action stride, optimum stepping reach and no “in-crotch” seaming.

In the outer seam hip area, in all three layers shall, incorporate convex seam technology to provide for generous seat expansion when squatting and crawling without creating unsightly bagginess.

That the diamond extend from just above the left knee to just above the right knee, and be centered equally from front to rear. Width of diamond at top of crotch shall be approximately proportionally graded to waist size and inseam length.

Ensure that pants rest in normal body line balance of 22 inches (55.9 cm) center distance at the cuff for 42 waist, 30 inseam pants.

Provide for an alteration point at the hips so that during manufacture the hip dimension can be adjustable in two-inch (5.0cm) increments

44.0 SUSPENDER BUTTONS

Eight (8) heavy duty, rust-resistant suspender buttons shall be positioned around the waist. Suspender buttons shall be mounted through waistband of triple layer outer shell material that is internally reinforced with an additional band of coated needlepunch aramid.

45.0 LINER ATTACHMENT

The moisture barrier and thermal liner assembly shall be attached to the outer shell at the waistband with seven (7) evenly-spaced glove snaps. Liners shall be attached at the cuff by means of snaps on two (2) sets of Nomex tabbing per liner cuff. The male and female snap parts shall both be located on Nomex tabbing that is sewn to the liner at the cuff. A separate piece of Nomex tabbing shall be sewn to the shell cuff and fashioned as a loop without any snap hardware.

46.0 PANT CERTIFICATION LABEL ON LINER

The pant certification label on the liner shall be affixed to the inner left hip area of the liner.

47.0 PANT CERTIFICATION LABEL ON SHELL

The pant label on the shell shall be affixed to the facing at the fly.

48.0 FLY FRONT

The outer shell fly shall be lockstitched to the left side of the front opening and shall be in proportion to waist size and crotch rise in both length and width. Fly inner lining shall extend at least 2 inches (5.1 cm) to the left of the outer shell fly attachment seam and shall be constructed of certified breathable moisture barrier and thermal liner.

The right front pant opening shall have an internal facing extending at least 2 inches (5.1 cm) to the right and constructed of specified fabric. In combination with the liner, the system shall offer 360-degree protection without gaps during movement of the outer shell moisture barrier and thermal liner. Closure shall be by means of a minimum 1.5-inch-wide (3.8-cm-wide) hook and loop fastener, and all construction techniques used shall provide liquid penetration protection under the NFPA 1971 Whole Garment Liquid Penetration Test. The fly shall be graded to the waist size of garments and crotch rise.

49.0 COMPOSITE MATERIALS

The specifier has determined the ONLY acceptable combination of materials. Any substitution of materials shall be grounds for immediate disqualification of quote without further consideration.

49.1 OUTER SHELL

Pioneer - Kevlar/Nomex Blend, 6.6 osy. Twill Weave - Gold

49.2 THERMAL LINING

Synergy II 2 Layer - 7.1 oz. calendared 100% spun 3.3 oz. Meta Aramid facecloth; 1 layer of 2.3 oz. E-89, and one layer 1.5 oz. E-89 (Berry Compliant)

49.3 MOISTURE BARRIER

Stedair 4000 - 3.2 oz/yd2 woven Nomex containing 2% carbon fibers, laminated to a PTFE membrane (Berry

Compliant)

50.0 PANT CUSTOM OPTIONS TO BE PROVIDED

Instructions in this custom options section that contradict earlier specifications or statements supersede those earlier specifications or statements as long as the required certifications are not compromised.

Std -Inspection Port Liner Std

Liner Detachable

Std -Trim Double-Stitched

Trim -(7) NFPA -lime 2-tone Oralite Brilliance (3")

Narrow Fly o 2" Velcro/Zipper o No Hook

Angled Cuffs - Arashield - Black

Pant Cuffs - Arashield - Black

BiFlex Heat Channel Knees o Both center sections in BiFlex Knee to be Arashield - Black

Bellows Pocket -1 -Pants - Pioneer - Gold o left leg o 9 x 9 x 1.5

Bellows Pocket (1) w/ Universal Escape System Adaptation o right leg o 9 x 9 x 2

Snap Style Suspender Attachment

Right/Left Spider Harness Pant Open o Lower Placement, o leg loops to be internally placed

Right over Left Spider Harness Model G *N/A w/30" Waist or less

Dyna-Fit Suspenders o With Snap Attach & o Metal Quick Adjust Installed

Suspender Padding

DELIVERY ORDERS

Delivery orders will be issued for all deliveries. The Contractor shall only provide the turnout gear ordered via a delivery order. The contract administrator will issue delivery orders against the contract and will provide a copy to the contractor via e-mail. The contractor shall not commence work without receipt of a delivery order from the Contract Administrator. In addition, the contractor shall not exceed the quantity on the delivery order without prior approval from the Contracting Officer.

CONTRACT MINIMUM/MAXIMUM QUANTITY AND CONTRACT VALUE

The minimum quantity and contract value for all orders issued against this contract shall not be less than the minimum quantity and contract value stated in the following table. The maximum quantity and contract value for all orders issued against this contract shall not exceed the maximum quantity and contract value stated in the following table.

MINIMUM

MINIMUM

AMOUNT

MAXIMUM

QUANTITY

MAXIMUM

AMOUNT

1.00 300.00

DELIVERY/TASK ORDER MINIMUM/MAXIMUM QUANTITY AND ORDER VALUE

The minimum quantity and order value for each Delivery/Task Order issued shall not be less than the minimum quantity and order value stated in the following table. The maximum quantity and order value for each

Delivery/Task Order issued shall not exceed the maximum quantity and order value stated in the following table.

MINIMUM

AMOUNT

MAXIMUM

QUANTITY

MAXIMUM

1.00 150.00

CLIN DELIVERY/TASK ORDER MINIMUM/MAXIMUM QUANTITY AND CLIN ORDER VALUE

The minimum quantity and order value for the given Delivery/Task Order issued for this CLIN shall not be less than the minimum quantity and order value stated in the following table. The maximum quantity and order value for the given Delivery/Task Order issued for this CLIN shall not exceed the maximum quantity and order value stated in the following table.

CLIN

QUANTITY

MINIMUM

AMOUNT

MAXIMUM

QUANTITY

MAXIMUM

INSPECTION AND ACCEPTANCE TERMS

Supplies/services will be inspected/accepted at:

CLIN INSPECT AT INSPECT BY ACCEPT AT ACCEPT BY

0001 Destination Government Destination Government

0002 Destination Government Destination Government

1001 Destination Government Destination Government

1002 Destination Government Destination Government

2001 Destination Government Destination Government

2002 Destination Government Destination Government

DELIVERY INFORMATION

CLIN DELIVERY DATE QUANTITY SHIP TO ADDRESS DODAAC /

CAGE

0001 POP 18-SEP-2018 TO

17-SEP-2019

N/A FREIGHT TRAFFIC BRANCH

RAUL VAZQUEZ

ATTN: CONTRACT #

ASH STREET BLDG 1118

CAMP LEJEUNE NC 28542-5000

910-449-9027

M31000

0002 POP 18-SEP-2018 TO

17-SEP-2019

N/A (SAME AS PREVIOUS LOCATION)

1001 POP 18-SEP-2019 TO

17-SEP-2020

N/A (SAME AS PREVIOUS LOCATION)

1002 POP 18-SEP-2019 TO

17-SEP-2020

N/A (SAME AS PREVIOUS LOCATION)

2001 POP 18-SEP-2020 TO

17-SEP-2021

N/A (SAME AS PREVIOUS LOCATION)

2002 POP 18-SEP-2020 TO

17-SEP-2021

N/A (SAME AS PREVIOUS LOCATION)

CLAUSES INCORPORATED BY REFERENCE

52.202-1 Definitions NOV 2013

52.203-3 Gratuities APR 1984

52.203-11 Certification And Disclosure Regarding Payments To

Influence Certain Federal Transactions

SEP 2007

52.203-12 Limitation On Payments To Influence Certain Federal

Transactions

OCT 2010

52.203-18 Prohibition on Contracting With Entities That Require Certain

Internal Confidentiality Agreements or Statements--

Representation

JAN 2017

52.203-19 Prohibition on Requiring Certain Internal Confidentiality

Agreements or Statements

JAN 2017

52.204-4 Printed or Copied Double-Sided on Postconsumer Fiber

Content Paper

MAY 2011

52.204-7 System for Award Management OCT 2016

52.204-9 Personal Identity Verification of Contractor Personnel JAN 2011

52.204-13 System for Award Management Maintenance OCT 2016

52.204-16 Commercial and Government Entity Code Reporting JUL 2016

52.204-18 Commercial and Government Entity Code Maintenance JUL 2016

52.204-19 Incorporation by Reference of Representations and

Certifications.

DEC 2014

52.204-22 Alternative Line Item Proposal JAN 2017

52.204-23 Prohibition on Contracting for Hardware, Software, and

Services Developed or Provided by Kaspersky Lab and Other

Covered Entities.

JUL 2018

52.209-10 Prohibition on Contracting With Inverted Domestic

Corporations

NOV 2015

52.211-6 Brand Name or Equal AUG 1999

52.211-17 Delivery of Excess Quantities SEP 1989

52.212-1 Instructions to Offerors--Commercial Items JAN 2017

52.212-4 Contract Terms and Conditions--Commercial Items JAN 2017

52.232-17 Interest MAY 2014

52.232-19 Availability Of Funds For The Next Fiscal Year APR 1984

52.232-39 Unenforceability of Unauthorized Obligations JUN 2013

52.232-40 Providing Accelerated Payments to Small Business

Subcontractors

DEC 2013

52.242-13 Bankruptcy JUL 1995

52.247-34 F.O.B. Destination NOV 1991

252.203-7000 Requirements Relating to Compensation of Former DoD

Officials

SEP 2011

252.203-7002 Requirement to Inform Employees of Whistleblower Rights SEP 2013

252.203-7005 Representation Relating to Compensation of Former DoD

Officials

NOV 2011

252.204-7003 Control Of Government Personnel Work Product APR 1992

252.204-7008 Compliance With Safeguarding Covered Defense Information

Controls

OCT 2016

252.204-7009 Limitations on the Use or Disclosure of Third-Party

Contractor Reported Cyber Incident Information

OCT 2016

252.204-7012 Safeguarding Covered Defense Information and Cyber

Incident Reporting

OCT 2016

252.204-7015 Notice of Authorized Disclosure of Information for Litigation

Support

MAY 2016

252.209-7004 Subcontracting With Firms That Are Owned or Controlled By

The Government of a Country that is a State Sponsor of

Terrorism

OCT 2015

252.223-7008 Prohibition of Hexavalent Chromium JUN 2013

252.225-7001 Buy American And Balance Of Payments Program-- Basic DEC 2017

252.225-7002 Qualifying Country Sources As Subcontractors DEC 2017

252.232-7003 Electronic Submission of Payment Requests and Receiving

Reports

JUN 2012

252.243-7001 Pricing Of Contract Modifications DEC 1991

252.243-7002 Requests for Equitable Adjustment DEC 2012

252.243-7002 Requests for Equitable Adjustment DEC 2012

252.244-7000 Subcontracts for Commercial Items JUN 2013

252.247-7023 Transportation of Supplies by Sea APR 2014

CLAUSES INCORPORATED BY FULL TEXT

52.212-2 EVALUATION--COMMERCIAL ITEMS (OCT 2014) ‘TAILORED”

(a) The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers:

The basis of the award is “Best Value” to the Government, using a trade-off process.

The criteria for evaluation are:

1) Technical Capability to include –

(a) Technical Specifications. The vendor’s quote shall provide the Brand Name or Equal items that meet all the specifications listed in the Technical Specifications and CLINs.

(b) Delivery: The Government requests delivery 45 days after receipt of a task order (ARO). Vendor shall clearly state if the quoter can meet the desired delivery of 45 days ARO or better. If not then vendor shall state delivery time following receipt of task order.

2) Past Performance

3) Price

Factor 1. The Subfactors are weighted equally.

Factor 2. If the contractor has no past performance history or relevant past performance, a rating of “neutral” will be assigned.

Factors 1 and 2 are weighted equally and when combined will be evaluated as significantly more important than Factor

3 – Price

This requirement contains Brand Name or Equal CLINs. Quotes will only be acceptable if quotes are provided for the brand name, or equal brands meeting the quality and specifications of the brand name.

The proposed acquisition is 100% set aside for Small Business in accordance with FAR 19.502-2(a).

The associated North American Industrial Classification System (NAICS) Code for this procurement is 339113. The industry description for this NAICS Code is Surgical Appliance and Supplies Manufacturing, which has a small business size standard of 750 employees.

This procurement is subject to the Buy American Act. If the product you are quoting on is not American made, you must identify the country in which it is made.

BASIS OF AWARD: This procurement is conducted in accordance with FAR Subpart 13.5 Simplified Acquisition

Procedures utilizing FAR Part 12 Acquisition of Commercial Items.

The term “offeror” or “offer” as used in FAR 52.212-1 shall be understood to mean “Quoter” and “quote,” respectively. Further, the term “award” shall be understood to describe the Government’s issuance of a purchase order in response to a request for quotes (RFQ).

EVALUATION. The Government intends to issue a single firm fixed-price Requirements contract on an "all or none" basis for this requirement. However, the Government reserves the right to award no contract at all, depending on the quality of the quotes submitted. The Government will award a single contract resulting from this request for quotes to the responsible vendor whose quote, conforming to the RFQ; will be most advantageous to the

Government, price and other factors considered. Quotes will be evaluated in an efficient and minimally burdensome fashion. The Contracting Officer reserves the right to evaluate quotes without the use of formal evaluation procedures such as establishing a competitive range, conducting discussions, scoring quotations, and to make an award to other than the lowest quote.

The Government intends to evaluate quotes and award a contract without discussions with vendors. Vendors should not expect requests for clarification or additional information from the Government. Therefore, the vendor’s initial quote should contain the vendor’s best terms from a price and technical standpoint. However, the Government reserves the right to conduct discussions with vendors if later determined by the Contracting Officer to be necessary and in the best interest to the Government. The Government may reject any or all quotes if such action is in the public interest; and may waive informalities and minor irregularities in quotes received.

1) TECHNICAL CAPABILITY

(a) Subfactor A: Technical Specifications. The vendor’s quote shall provide the Brand Name or Equal items listed in the CLINs and that meet all Technical Specifications. The quoter shall provide a detailed response that clearly demonstrates how the proposed product meets or exceeds the minimum requirements to each Technical

Specification. This shall include descriptive literature outlining the specifications of the items quoted to include drawings. The manufacturer’s name and manufacturer’s complete part numbers of all items quoted shall be submitted in the quote. Quotes shall clearly state all products specifications for all items quoted. Each factor in the technical specifications shall be addressed. Merely restating the Technical Specifications will not be considered acceptable.

(b) Subfactor B: Delivery: The Government requests delivery 45 days after receipt of a task order (ARO). Vendor shall clearly state if they can meet the desired delivery of 45 days ARO or better. If not then vendor shall state the delivery time required following receipt of task order.

Technical Capability will be evaluated based upon the extent to which the vendor concisely and accurately describes the technical solution to providing all items listed in the solicitation.

Technical Specifications will be evaluated for adherence to the stated requirements in the CLINS and Technical

Specifications. If the government determines that the specifications do not adhere to the Technical Specifications, the quotation will be found to be non-conforming and will not receive further consideration for award. Vendors who fail to submit the descriptive literature and address all technical specifications may not receive further consideration for award.

Upon a determination that a quotation is technically conforming, the vendor’s quotation will be evaluated for past performance.

2) PAST PERFORMANCE – For past performance, the vendor shall submit the attached Past Performance

Questionnaire, as part of its quote, information on previously performed contracts or on-going contracts that are similar to the item descriptions in the solicitation performed for Federal, State or local Governments, and for commercial firms. A determination will be made that the quoter has satisfied its customers in the past and demonstrated adequate experience in performing relevant similar projects of similar size, scope, and complexity within the past three (3) years. Information utilized to come to that conclusion will be obtained from the references listed in the quote, other customers known to the Government, consumer protection organizations, others who may have relevant information and a review of the vendor’s record in the Past Performance Information Retrieval System

(www.ppirs.gov),…