M25-026E Trucent CentraSep - Item Description.pdf
PDF 163 KB Posted
- Attached to
- Trucent CentraSep S-126 Centrifuges
- Solicitation number
- FA812625Q0020
About this file
The document is an Item Description for the procurement of two Trucent CentraSep S-126 Centrifuges for the 76th Maintenance Group Support Squadron (MXSG) at Tinker Air Force Base. The centrifuge system must meet specific technical requirements, including removing 98% of paint chip particles, processing 40-50 gallons per minute of fluid, fitting within a 13-foot x 24-foot area, and having stainless steel components. Additional specifications include dimensional constraints, power requirements, and technical features like a user-friendly Human Machine Interface (HMI) and NEMA-rated electrical enclosures.
The solicitation (FA812625Q0020) is a 100% small business set-aside with a NAICS code of 334516 and a size standard of 1,000 employees. The contract is expected to be a Firm Fixed Price type with a 60-day performance period. Vendors must be registered in the System for Award Management (SAM) and can submit proposals electronically through Beta.sam.gov. The procurement is being conducted by the Department of the Air Force Materiel Command Air Force Sustainment Center, with the goal of acquiring centrifuges that meet precise technical and operational specifications for wastewater processing equipment.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation - FA812625Q0020.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
OKLAHOMA CITY AIR LOGISTICS COMPLEX (OC-ALC)
TINKER AIR FORCE BASE OKLAHOMA
Item Description
TRUCENT CENTRASEP S-126 CENTRIFUGE
M25-026E
The 76th MXSG is requesting two (2) Trucent CentraSep S-126 or equal centrifuges. The Trucent CentraSep S-126 system shall consist of two control cabinets, two transfer tanks and piping required to connect the centrifuge and transfer tank. This requirement must have the following specifications:
• The centrifuge system shall have the capabilities of removing 98% of paint chip particles to prevent long-term damage and clogging in the wastewater processing equipment.
• The centrifuge system shall have the capabilities of receiving fluid from existing tank at approximate 40 to 50 gallons per minute. Fluid stream will have neutral pH, temperature under 140-degree F.
• The (2) centrifuges, (2) transfer tanks, (2) control cabinets, (2) transfer tanks, (2) pumps and utilities standards shall fit within the 13-foot x 24-foot area.
• Dimensions shall be width 60 inches to 72 inches, height 100 inches to 160 inches.
• The centrifuge bowl, scraper blade, accelerator, drive shaft and transfer tank shall be stainless steel.
• Shall come with a stand and/or elevated to gravity discharge the solid paint chip into a
55-gallon drum-22-1/2 inch diameter and 33-1/2 inch height standard drum.
• Pump inlet port shall be 3 inches to 1-1/2 inch.
• Clean discharge port shall be 4 inches to 6 inch.
• Solid holding capacity shall be 6 to 7 gallons.
• Compressed air requirement shall be 60 to 100 psi.
• Compressed air inlet shall be 3/8 inch or ½ inch.
• Transfer tank outlet to pump shall be 1-1/2 inch to 2 inches.
• Shall provide manuals and in-depth training to Tinker AFB personal.
• Shall include delivery of design drawings and specifications for approval prior to production start.
• Shall include copies of interconnect schematic, installation manual, service manual, and operation manual.
• The system shall be equipped with a user-friendly Human Machine Interface (HMI) to facilitate operational use, troubleshooting, and maintenance.
• All electrical components shall be housed in NEMA-rated enclosures, specifically NEMA 12, 3R, or 4, to ensure protection from environmental factors such as dust, water, and corrosion.
• The equipment shall be designed to operate on a 60Hz, 3-Phase, 480VAC power supply, with a maximum current rating of 80 amps.
• The Transfer Tank float switch shall provide a 120VAC signal to control the actuation of the transfer pump, which shall be supplied by the customer (Tinker)
• The filter system shall generate 2 separate digital signals for each filter (24VAC or 24VDC) to indicate an alarmed status or cleaning cycle.
• The Programmable Logic Controller (PLC) shall be a high-quality, industry-standard device from either Allen-Bradley or Siemens, ensuring compatibility, reliability, and ease of programming.
File details come from the government source that posted it. Updated .