LRWRP_Design_Report_Appendix_C.pdf
PDF 29 MB Posted
- Solicitation number
- 2025-RFP-015DW
- Issued by
- Santa Barbara County, Long Beach City, California
About this file
This is a design report appendix for the City of Lompoc's Regional Wastewater Reclamation Plant, prepared by consulting engineers and containing detailed technical specifications and equipment data sheets. The document provides plans, sections, and details for the influent pumping station and fabricated pump system, with multiple elevation views and scale drawings. The file includes pump data sheets for two pumping systems: a Fairbanks Morse pump with a design capacity of 5,210 US gallons per minute at 29 feet of head and a 50 horsepower motor, and a Morris pump with a capacity of 7.5 million gallons per day at 30 feet of head and approximately 48.5 horsepower. The document references structural requirements, including steel plate conformance to ASTM A36 or A490 Grade C standards with 3/8-inch plate thickness, and compliance with AWWA Specification C201 for all fabrication work.
The design report supports the current Headworks and Influent Meter Improvements Project, which builds upon previous master planning efforts including a 2002 master plan and 2005 design report that identified infrastructure upgrade needs at the facility. The specifications outline inlet piece construction requirements, grouting procedures, and internal bracing to prevent damage during foundation work. The pumping station design accommodates the plant's treatment of wastewater serving approximately 9,000 sewer connections with a current Average Dry Weather Flow capacity of 5.0 MGD. This technical documentation establishes the baseline requirements and performance criteria for the engineering consultant selected to develop preliminary and final design documents for the broader headworks improvements, with proposals due June 30, 2025.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPENDIX C
Alternative A - Existing Pumping Station
PLAN AT EL 52.0
SCALE : I/; = 1' 0
I i
P 7 . { d AND C A L D W E L L ' w S 337 M LOMPOC REGIONAL
APTROYED'
CONSULTING ENGINEES
Y ? l SAN FRAMCISCO. ALHAWLA, wmauu ,MAR.1974 ( WASTEWATER RECLAMATION PLANT
FABRICATED PUMP I
SECTION @ @ SEE. DWO 5205
SCALE a '/s" = 1'-0
SEE
SCALE : I// = 1'- 0
SCALE : l/al= 1'-0 jl-
,J
SAN FRANCISCO - ALMA
PLAN AT EL 68.0
SCALE8 '4'' = 1'- 0
I FOR CONi
SEE MTG 69 PLAN AT EL 96.0
SCALE: 1/4''= 1'-0
THICKENER
I
FMPC
Brant Williams Lompoc Shafted Non Clog Option
-,I y: 111408A
PUMP DATA SHEET
Fairbanks Morse Pump, 60 Hz
Design Point: Flow: 521 0 US gprn Head: 29 ft
I pump: 5700ANGLEFLO - 900 Size: 14"5711 (A)
Speed: 885 rpm Dia: 14.9375 in limits: Temperature: 150 "F
Pressure: 50 psig
.Fpecific Speed: Ns: 4135 bimensions: Suction: 14 in
Sphere size: 5.25 in Power: --- bhp
Nss: 8653
Discharge: 14 in
.Motor: 50 hp Speed: 900 Frame: 404T
1 NEMA Standard TEFC Enclosure sized for Max Power on Design Curve
---- Data Point ---- Flow: 5210 US gprn
Head: 29.4 ft
Eff: 82%
Power: 47.3 bhp
NPSHr: 11.4 ft
- Design Curve --i ahutoff Head: 46.6 ft
Shutoff dP: 20.2 psi
Min Flow: 1500 US gprn
BEP: 82% eff @ 5492 US gprn
NOL Pwr: 47.6 bhp @ 5492 US gprn
-- Max Curve -- Max Pwr: 98.8 bhp
@ 8240 US gprn
Flow Speed
USgpm rPm 6252 885 521 0 885 4168 885 3126 885 2084 885
H20ptimize ver: 6.041 1 011 4/04
Selection file: (untitled)
Catalog: FMCENT6O.MPC v 2.0
Fluid: Water Temperature: 60 "F
SG: 1
Viscosity: 1 .I 22 CP Vapor pressure: 0.2568 psia Aim pressure: 14.7 psia
NPSHa: --- ft Piping: System: ---
Suction: -- in Discharge: -- in
US gpm two 1600 2400 3200 4000 4800 5600 6400 7200
--- PERFORMANCE EVALUATION ---
Head Pump Power NPSHr Motor Motor Hrslyr Cost ft %eff bhp ft %eff kW /kwh
24 8 1 46.8 14.9
29.4 82 47.3 11.4
33.5 78 45.3 . 9.54 37 67 43.3 9
39.9 51 40.9 9
NEW PAGE
CO-
N
7- \NOTES - WM) INLET PIECES:
'1. STEEL PLATE SHALL CONFORM TO THE REQUIREK~S OF ASTM. A36 OR A W . GRADE C .
2. PLATE THICKNESS SHALL BE 3/8". WCEPT WHERE NOTED.
C54 INl.67
3. ALL ,FABRICATIWJ SHALL BE I N ACcEDANCE W/ AWWA SPECIFICATION C201..
6. CONTRACTOR SHALL 'PROVIDE bJi NECESSARY SUPPORTS AEP) INTERNAL BRACIffi TO
PREVENT DAMAGE OR DISTORTION OF IN-ET PIECES WRING WURMO OF THE FWATION
SUB. AFTER CONCRETE ARWND INLET PIECES HAS CURED. FILL ALL VOID SPACES
?EN WRm AND STEEL W/ GROUT UMER PRESSURE. .
7. REPLACE STEEL PLUGS AFTER GROUTING AM3 GRIND SMOOTH.
SHALL BE F I R D COATED. ALL WORK SHALL
BE I N ACCORDANCE W/
9. PROVIM CMILING SF8
DETAIL @
SCALE: I h"= 1'-0
S E C T I O N @ a S C A L E : 3/eU=I'-0
PUMP 'BASE AND INLET PIECE
P L A N
S C A L E : I%* 8 1'-0
STEEL SO66 PLATE .THICKNESS Y L ~ G T H AS R W ~ ' BY M F ~
SECTION @
SCALE: 1 1/2"= 1'-0
SCALE: I I/$= ~ ' f o f HIS DRAWING REDUCED
TO HALF SIZE
INFLUENT PUMPING STATION C REGIONAL .
RECLAMATION PLANT . PLANS, SECTION AND DETAIL
-ompoc Treatment Plant PUMP DATA SHEET
Morris Pumps, Aurora, IL
Selection list: ---rch Criteria:
,:low: 7.5 mgd Head: 30 ft Tolerance: -- % of head
Fluid: Water Temperature: 60 OF
SG: 1
Viscosity: 1 .I 05 CP Vapor pressure: 0.2563 psi a Atm pressure: 14.7 psi a
NPSHa: --ft
Advanced Criteria:
Preferred Operating Area: --- Secondary Operating Point: -- Max temperature: - "F Max suction pressure: - psi g Max sphere size: -- in Max power: --- bhp Max suction specific speed: --- (Nss) Min trim: -- % of max diameter Min head rise: -- % to shutoff
Curve Corrections: none
I ---- Data Point ----
Flow: 7.5 mgd
Head: 30.1 ft
Eff: 81%
Power: 48.5 bhp
NPSHr: 10.6 ft
I -- Design Cu we --
Shutoff Head: 53.1 ft
Shutoff dP: 23 psi
Min Flow: -- mgd
BEP: 85% eff @ 6.13 mgd
NOL Pwr: 48.6 bhp @ 7.96 mgd
Catalog: 7100 Heavy Duty Wastewater 60Hz vers .I
Pump: 1214193V Type: 7100EC Synch speed: 720 rpm Speed: 700 rprn Dia: 19.12 in Curve no.: BM-10648
Specific Speeds Ns: 3023
Dimensions:
Suction: 14 in
Nss: 10109
Pump Limits:
Temperature: 150 "F Pressure: 67 psi g Sphere size: 3.9 in Power: -- bhp
Motor: -- h~
Discharge: 12 in
I Max Pwr: 48.6 bhp @ 7.96 mgd
Speed: -- Frame: -- Standard: NEMA Enclosure: TEFC Sizing criteria: Max Power on Design Curve