Liquid Penetrant Inspection Report.pdf
PDF 1 MB Posted
- Attached to
- TUGCON; Jones Act Federal contract opportunity
- Solicitation number
- N3220526R6060
About this file
This is a Liquid Penetrant Inspection Report documenting nondestructive testing (NDT) performed on welded components for the USNS SPEARHEAD vessel. The inspection was conducted by GC Energy Services, a division of Gulf Copper, on June 14, 2025, under procedure GC-PT-WETSPRAY (version 1.0) with Quality Assurance approval from the NDT Manager and Level III approval from Jeff Johnson, both dated September 16, 2019.
The inspection examined filet welds on aluminum deck plating and tow rigs on both the port and starboard sides of the vessel. The work followed AWS D1.1 acceptance criteria and employed solvent-removable penetrant (Maganaflux 3048) applied by spray, with a 10-minute dwell time and solvent-based developer (Maganaflux 2678) applied by spray with a 10-minute development time. Surface preparation involved cleaning with lint-free rags and solvent, and inspection was performed under 1000 Lux lighting at ambient temperature. Ramon Quiroga, a Level II PT Inspector, conducted the examination and found no rejectable indications at the time of inspection. Attached photographs document the inspected areas, showing the marked weld locations and inspection results on the deck plating and tow rig connections.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 26R6060 RFP.pdf | ||
| Shipyard Data Template.xlsx | XLSX spreadsheet | |
| Towing General Arrangement.pdf | ||
| Towing Fitting Installation.pdf | ||
| Towing Checklist and Certificate of Seaworthiness.pdf | ||
| WD 20150213 Rev38.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Procedure: GC-PT-WETSPRAY ver 1.0 .
QA approval by: NDT Manager 09/16/2019 .
Level III approval by: Jeff Johnson 09/16/2019 .
Method Desciption inspection report format GCES-MT001
GCES Procedure Number:
Job Description:
Acceptance Criteria:
LIQUID PENETRANT INSPECTION REPORT
June 14,2025
107749-001-022-001-RQ
USNS
N/A
Date of Report:
Report Number:
Customer:
Purchase Order:
See pictures attached
Temperature of material:
16640
Ambient
SPEARHEAD
Check Plate On Deck And Tow Rigs
Filet Weld
Aluminum
Manufacturer: Maganaflux 3048
Manufacturer: Maganaflux
Lighting: 1000 Lux
Project
GCES Project Number:
Solvent Removable
107749-001-022-001
Cleaner Type: Solvent
GC-LPT Visible
AWS D1.1
Clean Weld With Cleaner
Penetrant Type:
Spray
Area of Examination:
Material:
Surface Preparation:
Comments:
Port Side Deck Plating And Tow Rigs Were Inspected
STBD Deck Plating And Tow Rigs Were Inspected
No rejectable indications found at the time of inspection.
Client Representative
Ramon Quiroga Level II PT Inspector
Developer Time:
Penetrant Application: Dwell Time: Spray 10 mins
10 minsDeveloper Application:
Pre Cleaning Method: Wipe with lint free rag and cleaner
Developer: Solvent Based Manufacturer: Maganaflux
Procedure: GC-PT-WETSPRAY ver 1.0 .
QA approval by: NDT Manager 09/16/2019 .
Level III approval by: Jeff Johnson 09/16/2019 .