This is a Liquid Penetrant Inspection Report documenting nondestructive testing (NDT) performed on welded components for the USNS SPEARHEAD vessel. The inspection was conducted by GC Energy Services, a division of Gulf Copper, on June 14, 2025, under procedure GC-PT-WETSPRAY (version 1.0) with Quality Assurance approval from the NDT Manager and Level III approval from Jeff Johnson, both dated September 16, 2019.

The inspection examined filet welds on aluminum deck plating and tow rigs on both the port and starboard sides of the vessel. The work followed AWS D1.1 acceptance criteria and employed solvent-removable penetrant (Maganaflux 3048) applied by spray, with a 10-minute dwell time and solvent-based developer (Maganaflux 2678) applied by spray with a 10-minute development time. Surface preparation involved cleaning with lint-free rags and solvent, and inspection was performed under 1000 Lux lighting at ambient temperature. Ramon Quiroga, a Level II PT Inspector, conducted the examination and found no rejectable indications at the time of inspection. Attached photographs document the inspected areas, showing the marked weld locations and inspection results on the deck plating and tow rig connections.

View the file

Other files for this federal contract opportunity

Other files attached to TUGCON; Jones Act, newest first.
File Type Posted
26R6060 RFP.pdf PDF
Shipyard Data Template.xlsx XLSX spreadsheet
Towing General Arrangement.pdf PDF
Towing Fitting Installation.pdf PDF
Towing Checklist and Certificate of Seaworthiness.pdf PDF
WD 20150213 Rev38.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Procedure: GC-PT-WETSPRAY ver 1.0 .

QA approval by: NDT Manager 09/16/2019 .

Level III approval by: Jeff Johnson 09/16/2019 .

Method Desciption inspection report format GCES-MT001

GCES Procedure Number:

Job Description:

Acceptance Criteria:

LIQUID PENETRANT INSPECTION REPORT

June 14,2025

107749-001-022-001-RQ

USNS

N/A

Date of Report:

Report Number:

Customer:

Purchase Order:

See pictures attached

Temperature of material:

16640

Ambient

SPEARHEAD

Check Plate On Deck And Tow Rigs

Filet Weld

Aluminum

Manufacturer: Maganaflux 3048

Manufacturer: Maganaflux

Lighting: 1000 Lux

Project

GCES Project Number:

Solvent Removable

107749-001-022-001

Cleaner Type: Solvent

GC-LPT Visible

AWS D1.1

Clean Weld With Cleaner

Penetrant Type:

Spray

Area of Examination:

Material:

Surface Preparation:

Comments:

Port Side Deck Plating And Tow Rigs Were Inspected

STBD Deck Plating And Tow Rigs Were Inspected

No rejectable indications found at the time of inspection.

Client Representative

Ramon Quiroga Level II PT Inspector

Developer Time:

Penetrant Application: Dwell Time: Spray 10 mins

10 minsDeveloper Application:

Pre Cleaning Method: Wipe with lint free rag and cleaner

Developer: Solvent Based Manufacturer: Maganaflux

Procedure: GC-PT-WETSPRAY ver 1.0 .

QA approval by: NDT Manager 09/16/2019 .

Level III approval by: Jeff Johnson 09/16/2019 .