LINE ITEMS LIST.pdf

PDF 266 KB Posted

Attached to
6530--PATIENT ROOM FURNITURE FOR WEST HAVEN CT
Solicitation number
36C24125Q0556
Issued by

View the file

Other files

File Type Posted
36C24125Q0556.docx DOCX document
STATEMENT OF WORK - OPPORTUNITIES-DESCRIPTION.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TECHNICAL SPECIFICATIONS OF NEEDS:

LINE ITEM: 1

BED-1: PLATFORM BEDS – QTY. 16

Basis of Design:

Platform bed

Norix – Prodigy – Freestanding Fully Enclosed

Model #: PRD100B

Finish: Harvest

Size: 82”x38”x18.5

BRAND NAME OR EQUAL:

• Shall be Anti-ligature, free-standing with fully enclosed bottom

• Non-removable glides included

• Design shall reflect residential design aesthetic

• Minimum weight to be 130lbs

• Additional weight (100 lbs.) may be added during manufacturing process (must be

• communicated with VA designer at time of order)

• Shall be tamper and contraband resistant

• Shall be made of 100% seamless polymer. It cannot be laminated.

• Shall have rounded edges

• Shall be impact resistant and tested to 1,500 lbs. static load.

• Shall contain some recycled contend

• Shall be made in U.S.A.

• 10-year limited replacement warrantee

• Product shall meet:

Environmental Test Standards

• Compliant with Healthier Hospitals guidelines

• GREENGUARD and GREENGUARD Gold Certified by UL Environment.

• Product certified for low chemical emissions to UL 2818. UL.COM/GG

Performance Test Standards

• PRD100 Floor Mount Bed – Tested to 1,500 lbs. static load

• PRD100B Free-standing Bed with Fully Enclosed

• Bottom – Tested to 1,500 lbs. static load

Flammability Test Standards

• State of California, Technical Bulletin No. 133, Flammability Test Procedure for Seating Furniture for Use in Public Occupancies

• State of California, Technical Bulletin No. 117, Flammability Test Procedure for Seating Furniture for Use in Public Occupancies

• UL 1056 Fire Test of Upholstered Furniture

• ASTM E1537 Test Method for Fire testing of Real Scale Upholstered

Furniture Items

• NFPA 261 Cigarette Ignition Resistance of Upholstered Furniture

LINE ITEM: 2

M-1: PLATFORM BED MATTRESS – QTY. 15

• Shall be polyurethane foam core encased in a reinforced ripstop, fire-retardant, polyurethane

• coated cover with radio frequency welded seams for enhanced hygiene, security and durability

• Shall be puncture, fluid, crack, peel, abrasion and bed back resistant

• Shall be anti-microbial and anti-fungal

• Shall have a breathable vent that repeals oil, water, blood, urine and other fluids

Flammability Test Standards

• Compliant with the following flammability standards:

• MRS6-3675 (36"W x 75"L x 6"H) 24 lbs. MRS6-3882 (38"W x 82"L x 6"H) 28.5 lbs.

• MRS6-3680 (36"W x 80"L x 6"H) 26 lbs.

• Note: Dimensional tolerances are +/- one inch.

• 16 CFR Part 1633 16 CFR Part 1632

• California Technical Bulletin 129

Performance Test Standards

• Tested to ASTM F1566 Hexagonal Roller Mattress Durability Test

• Tested to ASTM D751 Hydrostatic Resistance Test for Coated Fabrics

Environmental Test Standards

• GREENGUARD and GREENGUARD Gold Certified by UL Environment.

• Product certified for low chemical emissions to UL 2818. UL.COM/GG

• Shall be made us U.S.A.

• 5 Year Warranty

LINE ITEM: 3

BED-2: PLATFORM BED WITH MATTRESS AND RESTRAINTS – QTY. 1

Basis of Design:

Platform bed

Norix - Prodigy Model #: PRD100 Floor Mount Bed with restraint hardware kit Finish: Harvest Size: 82”x38”x18.5 A min, of 4 restrains are needed. 2 on each side. Placement TBD on site with VA staff.

• Shall be Anti-ligature, with no bottom panel

• Shall be anchored to the floor

• Non-removable glides included

• Additional weight (100 lbs.) may be added during manufacturing process (must be

• communicated at time of order)

• Minimum weight to be 130lbs

• Shall be tamper and contraband resistant

• Shall be made of 100% seamless polymer. It cannot be laminated.

• Shall have rounded edges

• Shall be impact resistant and tested to 1,500 lbs. static load.

• Shall contain some recycled contend

• Shall be made in U.S.A.

• 10-year limited replacement warrantee

• Product shall meet:

Environmental Test Standards

• Compliant with Healthier Hospitals guidelines

• GREENGUARD and GREENGUARD Gold Certified by UL Environment.

• Product certified for low chemical emissions to UL 2818. UL.COM/GG

Performance Test Standards

• PRD100 Floor Mount Bed – Tested to 1,500 lbs. static load

Flammability Test Standards

• State of California, Technical Bulletin No. 133, Flammability Test Procedure for Seating Furniture for Use in Public Occupancies

• State of California, Technical Bulletin No. 117, Flammability Test Procedure for Seating

• Furniture for Use in Public Occupancies

• UL 1056 Fire Test of Upholstered Furniture

• ASTM E1537 Test Method for Fire testing of Real Scale Upholstered Furniture

Items

• NFPA 261 Cigarette Ignition Resistance of Upholstered Furniture

Mattress:

• Basis of design:

• Norix - Remedy Silver Sealed Seam mattress: Comfort Shield Remedy – Silver

Secure

• Size: 36” x 80”x 6”

• Model#: MRS6-3680

• Shall be polyurethane foam core encased in a reinforced ripstop, fire-retardant, polyurethane

• coated cover with radio frequency welded seams for enhanced hygiene, security and durability

• Shall be puncture, fluid, crack, peel, abrasion and bed back resistant

• Shall be anti-microbial and anti-fungal

• Shall have a breathable vent that repeals oil, water, blood, urine and other fluids

Flammability Test Standards

Compliant with the following flammability standards:

MRS6-3675 (36"W x 75"L x 6"H) 24 lbs. MRS6-3882 (38"W x 82"L x 6"H) 28.5 lbs.

MRS6-3680 (36"W x 80"L x 6"H) 26 lbs.

Note: Dimensional tolerances are +/- one inch.

• 16 CFR Part 1633

• 16 CFR Part 1632

• California Technical Bulletin 129

Performance Test Standards

• Tested to ASTM F1566 Hexagonal Roller Mattress Durability Test

• Tested to ASTM D751 Hydrostatic Resistance Test for Coated Fabrics

Environmental Test Standards

GREENGUARD and GREENGUARD Gold Certified by UL Environment.

Product certified for low chemical emissions to UL 2818. UL.COM/GG

• Shall be made us U.S.A.

• 5 Year Warranty

Removable Restraint Kit:

Norix - Product#: PRDRR06K

6 restrain brackets are needed. 3 on each side – to be confirmed prior to order.

Restrain Straps NOT NEEDED.

LINE ITEM: 4

MHD-1: DESK – QTY. 14

For Location: See drawings / Appendix 1

Basis of Design:

Desk

Norix - Prodigy

Model #: PRD600

Finish: Harvest

Size: 35.5”x24”x30”H

• Shall be one piece, wood grain, 100% seamless polymer construction

• Shall be impact resistant, anti-ligature

• Shall have additional ballast to meet a minimum weight of 60lbs.

• Design shall reflect residential design aesthetic

• Shall promote infection-control,

• Shall be fluid, tamper, infestation, contraband resistant

• Includes all anchoring hardware for floor mounting and optional non-removable floor guide kit

• for a free-standing alternative. Shall Contain some recycled content.

• Made in the U.S.A.

• 10-year limited replacement warrantee

LINE ITEM: 5

MHF-1: OPEN CHEST – QTY. 16

Basis of Design:

Open Chest Norix - Prodigy Model #: PRD700 Finish: Harvest Size: 18”x30”x42”H Weight - 55lbs

• Shall be one piece, wood grain, 100% seamless polymer construction

• Shall be impact resistant, anti-ligature

• Shall have optional additional ballasting option if ever needed (min. 50lbs)

• Design shall reflect residential design aesthetic

• Shall promote infection-control,

• Shall be fluid, tamper, infestation, contraband resistant

• Includes all anchoring hardware for floor mounting and optional non-removable floor guide kit

• for a free-standing alternative. Shall Contain some recycled content.

• Made in the U.S.A.

• 10-year limited replacement warrantee

LINE ITEM: 6

IN-1: INSTALLATION SERVICES – QTY 1

Installation services shall meet all requirements stated within this Statement of Work, detailed in section 3.0 in addition to project specific requirements outlined below:

INSTALLATION SCHEDULE/PHASING:

This installation shall be conducted with the following phasing:

INSTALLATION TRIP (4): up to four installation trips may be required due to an active nature of the unit and trips will be planned based on rooms availability. Installation shall include delivery and installation of all items within.

File details come from the government source that posted it. Updated .