Text version
Commercial Door Operators 08 71 23-1 04/13/2022
SECTION 08 71 23 – COMMERICAL DOOR OPERATORS
PART 1 GENERAL
1.1 SUBMITTALS
A. Action Submittals:
1. Product Data: Manufacturer’s descriptive data and product attributes.
B. Closeout Submittals:
1. Operation and Maintenance Data.
1.2 QUALITY ASSURANCE
A. Installer Qualifications: Firm specializing in work of this Section, with minimum 2 years’ experience.
1.3 WARRANTY
A. Manufacturer’s 2 year warranty against material and manufacturing defects.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Contract Documents are based on products by LiftMaster. www.LiftMaster.com
B. Substitutions: Acceptable equal or higher
2.2 MANUFACTURED UNITS
A. Door Operators:
1. Model: H.50.11 Side mount motor with chain hoist
2. Operation: Hoist.
3. Drive type: V-belt primary reduction.
4. Mounting: Wall, some locations require mounting brackets
5. Disconnect for manual operation: Floor level emergency release sash chain hoist with electric interlock.
6. Rated duty cycle: Maximum 25 cycles per hour and 90 cycles per day.
7. Meet UL 325.
8. Motor: Listed by Underwriters Laboratories, sized to door conditions.
9. Enclosure: NEMA 1.
10. Travel rate: 8 to 9 inches per second.
11. Radio receiver: Logic 5.0 on-board; accept Security+ 2.0 rolling code technology remote controls and binary DIP switch remote controls. Non-operational per U.S. Air Force regulations
12. Internet connectivity: 50 channel FHSS myQ technology.
13. Control station: Three push button type in NEMA 1 enclosure.
14. Remote controls: None
15. Primary monitored entrapment protection: Photo eyes, rigid housing
16. Secondary non-monitored entrapment protection: Retro-reflective Photo eye
PART 3 EXECUTION
3.1 INSTALLATION
http://www.liftmaster.com/
Commercial Door Operators 08 71 23-2 04/13/2022
A. Install in accordance with manufacturer’s instructions.
3.2 CLOSEOUT ACTIVITIES
A. Test and adjust operators for proper operation.
B. Demonstration: Demonstrate operation and programming of operators to Owner.
END OF SECTION