LI 0003 ORDERING DATA_Redacted.pdf
PDF 82 KB Posted
- Attached to
- EXPANSION JOINT, PIP Federal contract opportunity
- Solicitation number
- SPMYM224Q1145
About this file
This document appears to be the ordering data for a federal contract opportunity for the procurement of an expansion joint. The key details are:
The expansion joint must meet the requirements of ASTM-F-1123 Standard Specification, including specific details on the joint size, operating pressure and temperature, flange drilling, and fluid to be handled. The joint will be hydrostatically tested at 60 psig, and certified test data is required.
The related federal contract opportunity is Solicitation Number SPMYM224Q1145 for the procurement of an "EXPANSION JOINT, PIP." The solicitation will be issued as a 100% small business set-aside using commercial and simplified acquisition procedures. The resultant award will be a firm-fixed price supply contract for FOB Destination delivery to Bremerton, WA. Offerors must comply with DFARS 252.204-7019 if implementing NIST SP 800-171, and provide information on the actual manufacturer and country of origin. Offers are due by 5 PM PDT on 5 April 2024.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SPMYM224Q1145.pdf | ||
| LI 0017 ORDERING DATA_Redacted.pdf | ||
| LI 0019 ORDERING DATA_Redacted.pdf | ||
| LI 0021 ORDERING DATA_Redacted.pdf | ||
| CDRL EXHIBIT H.pdf | ||
| LI 0001 ORDERING DATA_Redacted.pdf | ||
| LI 0009 ORDERING DATA_Redacted.pdf | ||
| LI 0023 ORDERING DATA_Redacted.pdf | ||
| CDRL EXHIBIT J.pdf | ||
| CDRL EXIBIT L.pdf | ||
| LI 0011 ORDERING DATA_Redacted.pdf | ||
| LI 0005 ORDERING DATA_Redacted.pdf | ||
| CDRL EXHIBIT C.pdf | ||
| CDRL EXHIBIT G.pdf | ||
| CDRL EXHIBIT K.pdf | ||
| LI 0007 ORDERING DATA_Redacted.pdf | ||
| LI 0013 ORDERING DATA_Redacted.pdf | ||
| LI 0015 ORDERING DATA_Redacted.pdf | ||
| CDRL EXHIBIT A.pdf | ||
| CDRL EXHIBIT B.pdf | ||
| CDRL EXHIBIT D.pdf | ||
| CDRL EXHIBIT E.pdf | ||
| CDRL EXHIBIT F.pdf | ||
| CDRL EXHIBIT I.pdf |
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MATERIAL ORDERING DATA
Any specification that is referenced in this Material Order Data sheet is required to be to the latest revision at time of award.
IDN: N4523A 4065-1219
ICN: 38VNH25605 KO: S01 KOI: 100
Paragraph 4 Ordering Data
ASTM-F-1123, STANDARD SPECIFICATION FOR NON-METALLIC EXPANSION JOINTS,
dated 31 DECEMBER 1987 (Reapproved 2019)
(From ASTM-F-1123) 4.1 Orders for products under this specification shall include the following information:
4.1.1 Inside diameter of connecting pipes (joint ID): 42 inches
4.1.2 Face-to-face dimension that is the flange-to-flange dimension into which the expansion joint is to be installed: 12 inches
4.1.3 Maximum and minimum operating pressure in pounds-force per square inch gage (pascals): 40 psig max. 21 psig min.
4.1.4 Maximum and minimum operating temperature in °F (°C): 105° F max. 60° F min.
4.1.5 Flange drilling in accordance with the appendix titled “Common Flange Dimension/Drilling Chart’’ of the Technical Handbook on Rubber Expansion Joints and Flexible Pipe Connectors (herein referred to as the Technical Handbook) or in accordance with special customer requirements: Drill ONE Flange only for 42" dia. joint - 38 (ea) 1- 5/16" dia holes on a 47-3/4" bolt dia circle
4.1.6 Fluid to be handled: SeaWater
4.1.7 This ASTM specification designation: ASTM F1123-87 (2019)
4.1.8 Movement data requirements (including shock or vibratory excursions if applicable):
Not Required
4.1.9 Design certification burst test if required (see 9.1): Not Required
4.1.10 Hydrostatic or special tests if required (see 9.2): Hydrostatic Test
4.1.11 Certification of expansion joint if required (see Section 12): Not Required
4.1.12 Certified detailed drawing of the expansion joint if required (see 12.2): Not Required
Additional Data requirements: Expansion joint will be hydrostatically tested at 60 psig.
Certified test data is required.
All unit, intermediate, and shipping containers must be marked in accordance with MIL-STD-129. Refer to DLA Procurement Note C20 for further instructions.