LBNL-B7W Temp Tensile_BID ISSUE_Drawings.pdf

PDF 7 MB Posted

Attached to
Temporary Tensile Structure Federal contract opportunity
Solicitation number
012023-LMP
Issued by
Department of Energy

View the file

Other files for this federal contract opportunity

Other files attached to Temporary Tensile Structure, newest first.
File Type Posted
RFQ 012023-LMP.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION A-A

5" MIN

CONCRETE

SLAB

6"Ø x 3'-0" STEEL

PIPE BOLLARD PIPE

(ASTM A-53),

POWDER-COAT

YELLOW FINISH

7"

AA

BASE PL

"x10" SQ W/

(4)

"x2

" HILTI

KB-TZ2-SS

DOME CAP

BRAILLE SHALL BE

POSITIONED BELOW

CORRESPONDING TEXT

IN A HORIZONTAL

FORMAT, FLUSH LEFT

OR CENTERED. IF TEXT

IS MULTI-LINED, BRAILLE

SHALL BE PLACED

BELOW ENTIRE TEXT.

1 2

3 4

15% MAX. OF HGT. OF UPPERCASE LETTER "I"

1 4

60%-110% MAX. HGT. OF

UPPERCASE LETTER "I"

5/8" MIN. - 2" MAX.

BASED ON HGT. OF

UPPERCASE LETTER "I"

3/8" MIN. FROM RAISED

BORDERS AND

DECORATIVE ELEMENTS

1/8" MIN. TO 4 TIMES RAISED CHARACTER STROKE MAX. PER SECTION 11B-703.2.7

135% -170% MAX. OF

RAISED CHARACTER

HEIGHT

3/8" MIN. FROM RAISED

BORDERS AND

DECORATIVE ELEMENTS

0.3"

SINGLE BRAILLE

CELL

0.1"

BLANK CELL SPACE

BETWEEN WORDS

NO RAISED DOT

RAISED DOT

BASE DIAMETER

0.059" - 0.063"

D

B

C

A TYPICAL SIGNAGE FORMAT - FLUSH LEFT (CENTERED, SIM.)

0.3"

SINGLE BRAILLE

CELL

0.1"

BLANK CELL SPACE

BETWEEN WORDS

NO RAISED DOT

RAISED DOT

BASE DIAMETER

0.059" - 0.063"

C

B TYPICAL BRAILLE DETAIL

M

I N

RAISED CHARACTERS

ROUNDED EDGE

C SECTION AT BRAILLE

D SECTION AT LETTERS

ROUNDED OR DOMED

BRAILLE

3"

7W

3 4

XE PRIMARY ENTRANCE

3 4

3 4

NON-GLARE NUMBER

CIRCLE WITH ACCENT

- 1" HIGH 'BUILDING NAME' & 3/4" 'MAIN

ENTRANCE' TACTILE LETTERING WITH BRAILLE

BELOW

- FLUSHED LEFT

- 9" X 17-3/4" TYP., U.O.N.

- 1/4" THICK ACRYLIC BASE PANEL WITH 1/8"

WIDE GROOVE

- 1/4" THICK ACRYLIC NUMBER CIRCLE

BUILDING

MAIN ENTRANCE 1 2"

NAME

7W

1 8

XF SECONDARY ENTRANCE

NON-GLARE NUMBER

CIRCLE

BUILDING

NON-GLARE

BUILDING NUMBER

CENTERED ON

NUMBER CIRCLE

Visitors please use

Main Entrance 3 8"

NAME

NON-GLARE BUILDING

NUMBER CENTERED ON

NUMBER CIRCLE TO

CONTRAST WITH FIELD

- 3/4" HIGH 'BUILDING NAME' & 5/8" 'SECONDARY

MESSAGE' TACTILE LETTERING WITH BRAILLE

BELOW

- FLUSHED LEFT

- 7" X 14" TYP., U.O.N.

- 1/4" THICK ACRYLIC BASE PANEL WITH 1/8" WIDE

GROOVE

- 1/4" THICK ACRYLIC NUMBER CIRCLE

ROUTER 1/2 ROUND

GROOVE ON BASE

PANEL

ROUTER 1/2 ROUND

GROOVE ON BASE

PANEL

E1 EXIT (U.O.N.)

3/16" THICK, TYP.

FLUSHED LEFT, 1" HIGH 70%

MIN. COLOR CONTRAST

BETWEEN LETTERS &

BACKGROUND, TYP.

EXIT

- 1" HIGH TACTILE LETTERING,

FLUSHED LEFT

- 7" X 4" TYP., U.O.N.

EXIT

CALIFORNIA GRADE 2

BRAILLE PER SECTION

11B-703.3

EXIT

9"

C

L

A

F

F

M

A X

T

O

B

A S

E L I N

E

O

F

H I G

H E

S T

L

N

E

O

F

R

A I S

E D

C

H A

R A

C T

E R

S

1" HIGH 70% MIN. COLOR

CONTRAST BETWEEN

LETTERS & BACKGROUND

PER CBC 11B-703.2

TYPICAL TACTILE EXIT / EXIT ROUTE

SIGNAGE - SEE ADJACENT ELEVATION

FOR MOUNTING HEIGHT

SIGN

E

X

R

O U

T E

E

X I T

T

P

F

B R

A I L L

E MATTE, NON-GLARE FINISH

A

F

F

M

I N

B

A S

E L I N

E

W E

S

N

E

B

R A

I L L E

NOTE:

FOR ALL SIGNAGE TYPES ABOVE, REFER TO ALL GENERAL SIGNAGE NOTES,

DETAILS 19B, 15, 6 ON THIS SHEET

A EXITING & ROOM ID

LOCATION OF TACTILE SIGNS

AT DOORS

1'-6"

MIN.

M I N

C

L

OF TACTILE CHARACTERS / SIGN

B TACTILE SIGNAGE CLR. REQUIREMENTS

PULL SIDE

PUSH SIDE

LOCATION OF TACTILE SIGNS

AT DOORS

M I N

1'-6"

MIN.

11.04.2022

BID ISSUE

11.04.2022

(PROGRESS, ESTIMATE, BID, CONSTRUCTION,

CONFORMED, REVISION, AS-BUILT)(IF REVISION, APPLIES ONLY TO REVISED WORK)

ISSUE PROFESSIONAL SEAL

PROJECT NO.

DRAWING NO. SHEET

DATE

SCALE

CAD FILE PATH

APPROVED BY

CHECKED BY

DRAWN BY

REMARKSDATE

BY

APPR'D

BY

CHECKED

BY

DRAWN

NUMBER

REVISIONCONSULTING FIRMCONSULTING FIRM CONSULTING A/E FIRM

FACILITIES DIVISION

UNIVERSITY OF CALIFORNIA

LAWRENCE BERKELEY NATIONAL LABORATORY

B-07 (FORMER)

B7W TEMPORARY TENSILE STRUCTURE

ARCHITECTURE INC.

203 Willow Street, Suite 501 San Francisco, CA 94109 Tel: 4 1 5 . 5 6 7 . 7 7 0 4 Fax: 4 1 5 . 5 6 7 . 7 7 0 5

B

05/16 PROGRESS ISSUE

C

07/16 90% CONCEPT DESIGN

D

08/25 100% CONCEPT DESIGN

E

05/06 100% PRELIMINARY DESIGN

F

08/05 95% FINAL DESIGN

G

10/07 100% FINAL DESIGN

H

11/04 BID ISSUE

BUILDING SIGNAGE

NTS

BOLLARDS

AS NOTED

BUILDING SIGNAGE TYPES

NTS

GENERAL SIGNAGE NOTES:

SIGNAGE SHALL COMPLY WITH ALL REQUIREMENTS OF CBC SECTION 703 AND LBNL INTERIOR SIGN

STANDARDS MANUAL, LATEST VERSION, U.O.N. SEE DETAIL 16 / - FOR TYPICAL TACTILE SIGNAGE DETAILS, AND DETAIL 29 / - FOR LOCATIONS .

1. TACTILE SIGNAGE INSTALLATION LOCATION - PER CBC SECTION 11B-703.4 WHERE A

TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONG THE LATCH

SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE

DOOR, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL.

WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE LEAFS, THE

SIGN SHALL BE LOCATED TO THE RIGHT OF THE RIGHT HAND DOOR. SIGNS CONTAINING

TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18" MIN.

BY 18 IN. MIN., CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC

OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION -

SEE DETAIL 19E ON THIS SHEET. WHERE PERMANENT IDENTIFICATION SIGNAGE IS

PROVIDED FOR ROOMS AND SPACES THEY SHALL BE LOCATED ON THE APPROACH SIDE

OF THE DOOR AS ONE ENTERS THE ROOM OR SPACE. SIGNS THAT IDENTIFY EXITS SHALL

BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE EXITS THE ROOM OR SPACE.

2. MOUNTING HEIGHT OF TACTILE SIGNAGE SHALL BE @ 48" A.F.F. MINIMUM TO BASELINE OF

THE LOWEST LINE OF BRAILLE CELLS; @ 60" A.F.F. MAX. TO BASELINE OF THE HIGHEST

LINE OF RAISED CHARACTERS, U.O.N.

3. RAISED CHARACTERS SHALL BE UPPERCASE SANS SERIF OR SIMPLE SERIF TYPE (5/8"

HIGH MIN., 2" HIGH MAX., U.O.N. - WITH PROPORTIONS COMPLYING WITH SECTION

11B-703.2),1/32 IN. MIN. ABOVE THEIR BACKGROUND, FORMATTED HORIZONTALLY.

4. GRADE 2 BRAILLE (COMPLYING WITH SECTION 11B-703.3) SHALL DUPLICATE RAISED

CHARACTERS AND BE POSITIONED BELOW THE CORRESPONDING TEXT IN A HORIZONTAL

FORMAT, FLUSH LEFT OR CENTERED. IF TEXT IS MULTI-LINED, BRAILLE SHALL BE PLACED

BELOW THE ENTIRE TEXT.

BRAILLE SHALL BE SEPARATED 3/8 IN. MIN. AND 1/2 IN. MAX. FROM ANY OTHER TACTILE

CHARACTERS AND 3/8 IN. MIN. FROM RAISED BORDERS AND DECORATIVE ELEMENTS

WHERE OCCURS.

FOR BRAILLE, THE INDICATION OF AN UPPERCASE LETTER OR LETTERS SHALL ONLY BE

USED BEFORE THE FIRST WORD OF SENTENCES, PROPER NOUNS AND NAMES,

INDIVIDUAL LETTERS OF THE ALPHABET, INITIALS, AND ACRONYMS.

5. CONTRAST: CHARACTERS & SYMBOLS SHALL HAVE A NON-GLARE FINISH AND CONTRAST

W/ THEIR BACKGROUND, EITHER LIGHT ON DARK BACKGROUND OR DARK ON A LIGHT

BACKGROUND.

6. WHERE PICTOGRAMS ARE PROVIDED, PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6"

MIN. CHARACTERS AND BRAILLE SHALL NOT BE LOCATED IN THE PICTOGRAM FIELD.

PICTOGRAMS SHALL HAVE TEXT DESCRIPTORS LOCATED DIRECTLY BELOW THE

PICTOGRAM FIELD. TEXT DESCRIPTORS SHALL COMPLY WITH SECTIONS 11B-703.2,

11B-703.3 AND 11B-703.4.

7. COMPLIANT TACTILE SIGNAGE AT GRADE-LEVEL EXIT DISCHARGE DOOR SHOULD READ

"EXIT." COORDINATE WITH OTHER REQUIREMENTS FOR SIGNAGE CHARACTERISTICS,

PARTICULARLY RAISED CHARACTERS AND BRAILLE, AS WELL AS LOCATION AND HEIGHT

REQUIREMENTS.

8. CHARACTERS AND THEIR BACKGROUND, ANY PLASTIC COVER, AND INSERTS SHALL HAVE

A NON-GLARE FINISH.

9. CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER LIGHT

CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT

BACKGROUND; SHALL BE IN A HORIZONTAL FORMAT; SHALL BE UPPERCASE OR

LOWERCASE, OR A COMBINATION OF BOTH; SHALL BE OF CONVENTIONAL FORM - NOT

ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE (OR OTHER UNUSUAL FORMS); SHALL BE

SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "O" IS 60% MIN. -

110% MAX. OF THE HEIGHT OF THE UPPERCASE LETTER "I". STROKE THICKNESS OF THE

UPPERCASE LETTER "I" SHALL BE 10% MIN. - 20% MAX. OF CHARACTER HEIGHT.

CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS OF

ADJACENT CHARACTERS, EXCLUDING WORD SPACES. SPACING BETWEEN INDIVIDUAL

CHARACTERS SHALL BE 10% MIN. - 35% MAX. OF CHARACTER HEIGHT. SPACING BETWEEN

THE BASELINES OF SEPARATE LINES OF CHARACTERS WITHIN A MESSAGE SHALL BE 135%

MIN. - 170% MAX. OF THE CHARACTER HEIGHT.

SIGNAGE SPECIFICATIONS

- REFER TO LBNL SIGNAGE STANDARDS.

- ALL SIGNAGE SHALL MEET THE FOLLOWING REQUIREMENTS:

1.

TACTILE WITH CONTRACTED GRADE 2 BRAILLE. SEE DETAIL 6/-.

2. 1" HIGH 70% MIN. COLOR CONTRAST BETWEEN LETTERS &

BACKGROUND, TYP.

3. 1/8" THICK MIN. (U.O.N.) PERMANENT TACTILE PANEL

4. FOR MOUNTING HEIGHTS AND LOCATIONS, SEE DETAIL 19 / -

5. VERIFY ROOM NUMBERS, COLORS, AND VERBIAGE WITH LBNL,

COMPLETE SUBMITTAL REQUIRED FOR REVIEW.

6. VERIFY ALL LOCATIONS TO MAKE CERTAIN SIGNS FIT PRIOR TO

SUBMITTAL REVIEW.

7. MATTE, NON-GLARE FINISH, TYP.

8. 70% MIN. COLOR CONTRAST BETWEEN LETTERS & BACKGROUND

9. ALL TACTILE NUMBER / MESSAGE PANEL EDGES SHALL BE

CONTINUOUS CHAMFERED, EASED, OR ROUNDED.

10. ALL SIGNAGE AT EXTERIOR SHALL BE EXTERIOR GRADE - UV

RESISTANT.

TACTILE SIGNAGE CHARACTER & BRAILLE DTL.S, TYP.

N.T.S.

TACTILE SIGNAGE & MOUNTING INFO., TYP.

N.T.S.

DETAILS

A9.3

MS

AS NOTED

LBNL-B7 Temp Tensile_BID ISSUE_Civil
LBNL-B7 Temp Tensile_BID ISSUE_Architectural
A0.1_Cover
A0.3_Exiting
A1.0_Existing Site Plan
A2.0_Proposed Site Plan
A2.1_Proposed Plan
A2.2_Proposed Roof Plan
A3.1_Elevations
A3.2_Elevations_Plan
A4.1_Sections
A6.1_RCP
A9.2_Details
A9.3_Details
LBNL-B7 Temp Tensile_BID ISSUE_Structural
LBNL-B7 Temp Tensile_BID ISSUE_Mechanical
LBNL-B7 Temp Tensile_BID ISSUE_Plumbing
LBNL-B7 Temp Tensile_BID ISSUE_Electrical

File details come from the government source that posted it. Updated .