LBNL-B7W Temp Tensile_BID ISSUE_Drawings.pdf
PDF 7 MB Posted
- Attached to
- Temporary Tensile Structure Federal contract opportunity
- Solicitation number
- 012023-LMP
- Issued by
- Department of Energy
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFQ 012023-LMP.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION A-A
5" MIN
CONCRETE
SLAB
6"Ø x 3'-0" STEEL
PIPE BOLLARD PIPE
(ASTM A-53),
POWDER-COAT
YELLOW FINISH
7"
AA
BASE PL
"x10" SQ W/
(4)
"x2
" HILTI
KB-TZ2-SS
DOME CAP
BRAILLE SHALL BE
POSITIONED BELOW
CORRESPONDING TEXT
IN A HORIZONTAL
FORMAT, FLUSH LEFT
OR CENTERED. IF TEXT
IS MULTI-LINED, BRAILLE
SHALL BE PLACED
BELOW ENTIRE TEXT.
1 2
3 4
15% MAX. OF HGT. OF UPPERCASE LETTER "I"
1 4
60%-110% MAX. HGT. OF
UPPERCASE LETTER "I"
5/8" MIN. - 2" MAX.
BASED ON HGT. OF
UPPERCASE LETTER "I"
3/8" MIN. FROM RAISED
BORDERS AND
DECORATIVE ELEMENTS
1/8" MIN. TO 4 TIMES RAISED CHARACTER STROKE MAX. PER SECTION 11B-703.2.7
135% -170% MAX. OF
RAISED CHARACTER
HEIGHT
3/8" MIN. FROM RAISED
BORDERS AND
DECORATIVE ELEMENTS
0.3"
SINGLE BRAILLE
CELL
0.1"
BLANK CELL SPACE
BETWEEN WORDS
NO RAISED DOT
RAISED DOT
BASE DIAMETER
0.059" - 0.063"
D
B
C
A TYPICAL SIGNAGE FORMAT - FLUSH LEFT (CENTERED, SIM.)
0.3"
SINGLE BRAILLE
CELL
0.1"
BLANK CELL SPACE
BETWEEN WORDS
NO RAISED DOT
RAISED DOT
BASE DIAMETER
0.059" - 0.063"
C
B TYPICAL BRAILLE DETAIL
M
I N
RAISED CHARACTERS
ROUNDED EDGE
C SECTION AT BRAILLE
D SECTION AT LETTERS
ROUNDED OR DOMED
BRAILLE
3"
7W
3 4
XE PRIMARY ENTRANCE
3 4
3 4
NON-GLARE NUMBER
CIRCLE WITH ACCENT
- 1" HIGH 'BUILDING NAME' & 3/4" 'MAIN
ENTRANCE' TACTILE LETTERING WITH BRAILLE
BELOW
- FLUSHED LEFT
- 9" X 17-3/4" TYP., U.O.N.
- 1/4" THICK ACRYLIC BASE PANEL WITH 1/8"
WIDE GROOVE
- 1/4" THICK ACRYLIC NUMBER CIRCLE
BUILDING
MAIN ENTRANCE 1 2"
NAME
7W
1 8
XF SECONDARY ENTRANCE
NON-GLARE NUMBER
CIRCLE
BUILDING
NON-GLARE
BUILDING NUMBER
CENTERED ON
NUMBER CIRCLE
Visitors please use
Main Entrance 3 8"
NAME
NON-GLARE BUILDING
NUMBER CENTERED ON
NUMBER CIRCLE TO
CONTRAST WITH FIELD
- 3/4" HIGH 'BUILDING NAME' & 5/8" 'SECONDARY
MESSAGE' TACTILE LETTERING WITH BRAILLE
BELOW
- FLUSHED LEFT
- 7" X 14" TYP., U.O.N.
- 1/4" THICK ACRYLIC BASE PANEL WITH 1/8" WIDE
GROOVE
- 1/4" THICK ACRYLIC NUMBER CIRCLE
ROUTER 1/2 ROUND
GROOVE ON BASE
PANEL
ROUTER 1/2 ROUND
GROOVE ON BASE
PANEL
E1 EXIT (U.O.N.)
3/16" THICK, TYP.
FLUSHED LEFT, 1" HIGH 70%
MIN. COLOR CONTRAST
BETWEEN LETTERS &
BACKGROUND, TYP.
EXIT
- 1" HIGH TACTILE LETTERING,
FLUSHED LEFT
- 7" X 4" TYP., U.O.N.
EXIT
CALIFORNIA GRADE 2
BRAILLE PER SECTION
11B-703.3
EXIT
9"
C
L
A
F
F
M
A X
T
O
B
A S
E L I N
E
O
F
H I G
H E
S T
L
N
E
O
F
R
A I S
E D
C
H A
R A
C T
E R
S
1" HIGH 70% MIN. COLOR
CONTRAST BETWEEN
LETTERS & BACKGROUND
PER CBC 11B-703.2
TYPICAL TACTILE EXIT / EXIT ROUTE
SIGNAGE - SEE ADJACENT ELEVATION
FOR MOUNTING HEIGHT
SIGN
E
X
R
O U
T E
E
X I T
T
P
F
B R
A I L L
E MATTE, NON-GLARE FINISH
A
F
F
M
I N
B
A S
E L I N
E
W E
S
N
E
B
R A
I L L E
NOTE:
FOR ALL SIGNAGE TYPES ABOVE, REFER TO ALL GENERAL SIGNAGE NOTES,
DETAILS 19B, 15, 6 ON THIS SHEET
A EXITING & ROOM ID
LOCATION OF TACTILE SIGNS
AT DOORS
1'-6"
MIN.
M I N
C
L
OF TACTILE CHARACTERS / SIGN
B TACTILE SIGNAGE CLR. REQUIREMENTS
PULL SIDE
PUSH SIDE
LOCATION OF TACTILE SIGNS
AT DOORS
M I N
1'-6"
MIN.
11.04.2022
BID ISSUE
11.04.2022
(PROGRESS, ESTIMATE, BID, CONSTRUCTION,
CONFORMED, REVISION, AS-BUILT)(IF REVISION, APPLIES ONLY TO REVISED WORK)
ISSUE PROFESSIONAL SEAL
PROJECT NO.
DRAWING NO. SHEET
DATE
SCALE
CAD FILE PATH
APPROVED BY
CHECKED BY
DRAWN BY
REMARKSDATE
BY
APPR'D
BY
CHECKED
BY
DRAWN
NUMBER
REVISIONCONSULTING FIRMCONSULTING FIRM CONSULTING A/E FIRM
FACILITIES DIVISION
UNIVERSITY OF CALIFORNIA
LAWRENCE BERKELEY NATIONAL LABORATORY
B-07 (FORMER)
B7W TEMPORARY TENSILE STRUCTURE
ARCHITECTURE INC.
203 Willow Street, Suite 501 San Francisco, CA 94109 Tel: 4 1 5 . 5 6 7 . 7 7 0 4 Fax: 4 1 5 . 5 6 7 . 7 7 0 5
B
05/16 PROGRESS ISSUE
C
07/16 90% CONCEPT DESIGN
D
08/25 100% CONCEPT DESIGN
E
05/06 100% PRELIMINARY DESIGN
F
08/05 95% FINAL DESIGN
G
10/07 100% FINAL DESIGN
H
11/04 BID ISSUE
BUILDING SIGNAGE
NTS
BOLLARDS
AS NOTED
BUILDING SIGNAGE TYPES
NTS
GENERAL SIGNAGE NOTES:
SIGNAGE SHALL COMPLY WITH ALL REQUIREMENTS OF CBC SECTION 703 AND LBNL INTERIOR SIGN
STANDARDS MANUAL, LATEST VERSION, U.O.N. SEE DETAIL 16 / - FOR TYPICAL TACTILE SIGNAGE DETAILS, AND DETAIL 29 / - FOR LOCATIONS .
1. TACTILE SIGNAGE INSTALLATION LOCATION - PER CBC SECTION 11B-703.4 WHERE A
TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONG THE LATCH
SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE
DOOR, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL.
WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE LEAFS, THE
SIGN SHALL BE LOCATED TO THE RIGHT OF THE RIGHT HAND DOOR. SIGNS CONTAINING
TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18" MIN.
BY 18 IN. MIN., CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC
OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION -
SEE DETAIL 19E ON THIS SHEET. WHERE PERMANENT IDENTIFICATION SIGNAGE IS
PROVIDED FOR ROOMS AND SPACES THEY SHALL BE LOCATED ON THE APPROACH SIDE
OF THE DOOR AS ONE ENTERS THE ROOM OR SPACE. SIGNS THAT IDENTIFY EXITS SHALL
BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE EXITS THE ROOM OR SPACE.
2. MOUNTING HEIGHT OF TACTILE SIGNAGE SHALL BE @ 48" A.F.F. MINIMUM TO BASELINE OF
THE LOWEST LINE OF BRAILLE CELLS; @ 60" A.F.F. MAX. TO BASELINE OF THE HIGHEST
LINE OF RAISED CHARACTERS, U.O.N.
3. RAISED CHARACTERS SHALL BE UPPERCASE SANS SERIF OR SIMPLE SERIF TYPE (5/8"
HIGH MIN., 2" HIGH MAX., U.O.N. - WITH PROPORTIONS COMPLYING WITH SECTION
11B-703.2),1/32 IN. MIN. ABOVE THEIR BACKGROUND, FORMATTED HORIZONTALLY.
4. GRADE 2 BRAILLE (COMPLYING WITH SECTION 11B-703.3) SHALL DUPLICATE RAISED
CHARACTERS AND BE POSITIONED BELOW THE CORRESPONDING TEXT IN A HORIZONTAL
FORMAT, FLUSH LEFT OR CENTERED. IF TEXT IS MULTI-LINED, BRAILLE SHALL BE PLACED
BELOW THE ENTIRE TEXT.
BRAILLE SHALL BE SEPARATED 3/8 IN. MIN. AND 1/2 IN. MAX. FROM ANY OTHER TACTILE
CHARACTERS AND 3/8 IN. MIN. FROM RAISED BORDERS AND DECORATIVE ELEMENTS
WHERE OCCURS.
FOR BRAILLE, THE INDICATION OF AN UPPERCASE LETTER OR LETTERS SHALL ONLY BE
USED BEFORE THE FIRST WORD OF SENTENCES, PROPER NOUNS AND NAMES,
INDIVIDUAL LETTERS OF THE ALPHABET, INITIALS, AND ACRONYMS.
5. CONTRAST: CHARACTERS & SYMBOLS SHALL HAVE A NON-GLARE FINISH AND CONTRAST
W/ THEIR BACKGROUND, EITHER LIGHT ON DARK BACKGROUND OR DARK ON A LIGHT
BACKGROUND.
6. WHERE PICTOGRAMS ARE PROVIDED, PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6"
MIN. CHARACTERS AND BRAILLE SHALL NOT BE LOCATED IN THE PICTOGRAM FIELD.
PICTOGRAMS SHALL HAVE TEXT DESCRIPTORS LOCATED DIRECTLY BELOW THE
PICTOGRAM FIELD. TEXT DESCRIPTORS SHALL COMPLY WITH SECTIONS 11B-703.2,
11B-703.3 AND 11B-703.4.
7. COMPLIANT TACTILE SIGNAGE AT GRADE-LEVEL EXIT DISCHARGE DOOR SHOULD READ
"EXIT." COORDINATE WITH OTHER REQUIREMENTS FOR SIGNAGE CHARACTERISTICS,
PARTICULARLY RAISED CHARACTERS AND BRAILLE, AS WELL AS LOCATION AND HEIGHT
REQUIREMENTS.
8. CHARACTERS AND THEIR BACKGROUND, ANY PLASTIC COVER, AND INSERTS SHALL HAVE
A NON-GLARE FINISH.
9. CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER LIGHT
CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT
BACKGROUND; SHALL BE IN A HORIZONTAL FORMAT; SHALL BE UPPERCASE OR
LOWERCASE, OR A COMBINATION OF BOTH; SHALL BE OF CONVENTIONAL FORM - NOT
ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE (OR OTHER UNUSUAL FORMS); SHALL BE
SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "O" IS 60% MIN. -
110% MAX. OF THE HEIGHT OF THE UPPERCASE LETTER "I". STROKE THICKNESS OF THE
UPPERCASE LETTER "I" SHALL BE 10% MIN. - 20% MAX. OF CHARACTER HEIGHT.
CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS OF
ADJACENT CHARACTERS, EXCLUDING WORD SPACES. SPACING BETWEEN INDIVIDUAL
CHARACTERS SHALL BE 10% MIN. - 35% MAX. OF CHARACTER HEIGHT. SPACING BETWEEN
THE BASELINES OF SEPARATE LINES OF CHARACTERS WITHIN A MESSAGE SHALL BE 135%
MIN. - 170% MAX. OF THE CHARACTER HEIGHT.
SIGNAGE SPECIFICATIONS
- REFER TO LBNL SIGNAGE STANDARDS.
- ALL SIGNAGE SHALL MEET THE FOLLOWING REQUIREMENTS:
1.
TACTILE WITH CONTRACTED GRADE 2 BRAILLE. SEE DETAIL 6/-.
2. 1" HIGH 70% MIN. COLOR CONTRAST BETWEEN LETTERS &
BACKGROUND, TYP.
3. 1/8" THICK MIN. (U.O.N.) PERMANENT TACTILE PANEL
4. FOR MOUNTING HEIGHTS AND LOCATIONS, SEE DETAIL 19 / -
5. VERIFY ROOM NUMBERS, COLORS, AND VERBIAGE WITH LBNL,
COMPLETE SUBMITTAL REQUIRED FOR REVIEW.
6. VERIFY ALL LOCATIONS TO MAKE CERTAIN SIGNS FIT PRIOR TO
SUBMITTAL REVIEW.
7. MATTE, NON-GLARE FINISH, TYP.
8. 70% MIN. COLOR CONTRAST BETWEEN LETTERS & BACKGROUND
9. ALL TACTILE NUMBER / MESSAGE PANEL EDGES SHALL BE
CONTINUOUS CHAMFERED, EASED, OR ROUNDED.
10. ALL SIGNAGE AT EXTERIOR SHALL BE EXTERIOR GRADE - UV
RESISTANT.
TACTILE SIGNAGE CHARACTER & BRAILLE DTL.S, TYP.
N.T.S.
TACTILE SIGNAGE & MOUNTING INFO., TYP.
N.T.S.
DETAILS
A9.3
MS
AS NOTED
| LBNL-B7 Temp Tensile_BID ISSUE_Civil |
| LBNL-B7 Temp Tensile_BID ISSUE_Architectural |
| A0.1_Cover |
| A0.3_Exiting |
| A1.0_Existing Site Plan |
| A2.0_Proposed Site Plan |
| A2.1_Proposed Plan |
| A2.2_Proposed Roof Plan |
| A3.1_Elevations |
| A3.2_Elevations_Plan |
| A4.1_Sections |
| A6.1_RCP |
| A9.2_Details |
| A9.3_Details |
| LBNL-B7 Temp Tensile_BID ISSUE_Structural |
| LBNL-B7 Temp Tensile_BID ISSUE_Mechanical |
| LBNL-B7 Temp Tensile_BID ISSUE_Plumbing |
| LBNL-B7 Temp Tensile_BID ISSUE_Electrical |
File details come from the government source that posted it. Updated .