Asbestos & Lead‐Paint Survey Report

USIBWC Las Cruces Yard

504S.Miranda
LasCruces,NewMexico
RequestforProposal(RFP)#12‐05

IDIQ Fixed Price Proposal Contract IBM09D0010

Prepared for:

U.S. International Boundary and Water Commission

4171N.MesaSt.,SuiteC‐100
ElPaso,Texas79902‐1441

Submitted by:

7600 North 16th Street, Suite 110

Phoenix, Arizona 85020 Telephone: (602) 266-8288 Facsimile: (602) 266-9355

April 18, 2013

Asbestos and Lead-Based Paint Survey Report Page i IBWC Las Cruces Field Office, Las Cruces, New Mexico April 18, 2013

Table of Contents

1.0 INTRODUCTION

2.0 BUILDING DESCRIPTIONS

3.0 BACKGROUND

3.1 Asbestos Containing Materials

3.2 Asbestos Sampling and Analytical Procedures

4.0 ASBESTOS FINDINGS

4.1 Asbestos Containing Materials (>1%)

4.2 Negative Materials

5.0 ASBESTOS RECOMMENDATIONS

6.0 LEAD-BASED PAINT INSPECTION

6.1 Definition of Lead-Based Paint

6.2 Sampling and Analytical Procedures

7.0 SUMMARY OF LEAD-BASED PAINT TESTING RESULTS

8.0 LEAD-BASED PAINT RECOMMENDATIONS

8.1 Lead-Based Paint General Recommendations

9.0 DISCLAIMER

10.0 SIGNATORY

Tables – Homogeneous Materials Table

Appendices

Appendix A-Bulk Asbestos Sample laboratory Report

Appendix B-Lead-Based Paint XRF Field Data sheets

Appendix C-Sample Location Drawings

Appendix D- Photographs

Appendix E - Inspector Certifications

Asbestos and Lead-Based Paint Survey Report Page 1

1.0 Introduction

TRC Environmental Corporation (TRC) was contracted by the United States International Boundary and Water Commission (IBWC) to conduct an asbestos and a lead based paint survey at the Las Cruces Yard located at 504 S. Miranda, Las Cruces, New Mexico. The survey was performed on December 10, 2013, by Mr. Joseph Bohnaker, an EPA Accredited AHERA Asbestos Building inspector and EPA-trained Lead-Paint Inspector employed by TRC. The survey included the inspection and assessment of accessible interior and exterior construction materials associated with the building structures on site.

The asbestos and lead-based paint survey findings will be used to effectively manage asbestos-containing materials (ACM) and Lead-Based Paint (LBP) in the scope areas of the Las Cruces Field Office structures (the “Site”). The accumulated assessment information may be used in operations and maintenance plans for the facility designed to prevent accidental disturbance to ACM and LBP.

2.0 Building Descriptions

The following provides a summary of the Las Cruces Yard areas defined as the scope of work areas under Contract # IBM09D0010. All of the structures are located on federal land, were considered non-public buildings, are secured by fencing/locked gates, and have industrial processes. A description of the building structures are as follows:

Building Name Construction Type/Description

Administration Building

The building consists of a concrete pad, metal exterior walls with wood framing. The room if metal. The building comprises approximately 2500 square feet of area and is single-story.

Residence

The building is of block construction built slab on grade. The interior walls are drywall construction with masonry exterior walls. The building has a shingled roof. The building comprises approximately 1,620 square feet of area and is single-story.

Storage Shed The building consists of a concrete pad, metal exterior walls with a metal roof. The building houses tool storage and shop. The building comprises approximately 100 square feet of area and is single-story.

Storage Sheds The buildings consist of concrete pads with metal exterior walls and roofs.

Parking Shed The building consists of a concrete pad, metal exterior walls and a metal roof.

Telecom Building The building is a pre-fabricated concrete building with a built-up roof.

Paint Shed The building is a pre-fabricated metal building.

3.0 Background

3.1 Asbestos Containing Materials

The Occupational Safety and Health Administration (OSHA) and the Environmental Protection Agency (EPA) define an asbestos-containing material (ACM) as any material containing more than one percent (>1.0%) asbestos by weight. In addition, ACM are designated by the EPA into one of three characteristic categories as follows:

Asbestos and Lead-Based Paint Survey Report Page 2

Friable asbestos - material which can be crumbled, pulverized or reduced to powder by hand pressure, a.k.a. Regulated Asbestos Containing Materials (RACM)

Category I Non-friable - includes resilient floor coverings, asphalt roofing products, gaskets and packing. These materials may become friable if degraded or damaged to the point where the material can be crumbled, pulverized or reduced to powder by hand pressure.

Category II Non-friable - any non-friable ACM that is not in Category I (i.e. Asbestos-cement (Transite®) siding or roofing mastics).

3.2 Asbestos Sampling and Analytical Procedures

Representative bulk samples of suspect asbestos-containing building materials were randomly collected from the identified homogenous building material applications. Homogenous material determination was based on the following criteria:

Similar physical characteristics (same appearance, age, color and texture, etc.), Application (e.g. sprayed or trowel-on, assembly into a system, etc.), Material function (e.g. thermal insulation, floor tile, wallboard system, etc.).

Laboratory services were provided by TRC’s laboratory located in Windsor, Connecticut. TRC’s analytical laboratory is a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory (NVLAP code # 101424-0) and is in compliance with the National Environmental Laboratory Accreditation Conference (NELAC) requirements.

Bulk samples were analyzed by polarized light microscopy (PLM) utilizing the EPA’s Test Methods: Methods for the Determination of Asbestos in Bulk Building Materials (EPA 600/R- 93/116, July 1993) and the McCrone Research Institute’s The Asbestos Particle Atlas as method references.

Analysis by PLM was performed by visual observation of the bulk sample and by microscopic analysis using dispersion staining PLM methodology. The samples were analyzed for asbestiform minerals (Chrysotile, Amosite, Crocidolite, Anthophyllite, Actinolite, and Tremolite), fibrous non-asbestos constituents (mineral wool, cellulose, etc.) and non-fibrous constituents. Using a stereoscope, the microscopist visually estimates the relative amounts of each constituent by determining the estimated area of the asbestos compared with the area estimate of the total sample.

4.0 Asbestos Findings

Suspect Asbestos-Containing Materials (ACM), including building materials/finishes, insulated wire, and equipment/machinery components, e.g., gaskets, packing, dampening materials and insulation were inspected, sampled and analyzed for asbestos. Typical suspect building materials include finishes (e.g. drywall systems, suspended ceiling panels, glued ceiling tiles, floor tiles, vinyl sheet flooring, floor finish adhesives, cove base, cove base adhesive, textured coatings, roofing materials, caulks, sealants, and plasters. Non-suspect asbestos materials are items purely composed of glass, metal, concrete, rubber, brick, ceramic, grouts, fiberglass, foam, Styrofoam, and paper.

According to federal regulations, regulated ACM are ACMs containing greater than 1% asbestos by weight.

Asbestos and Lead-Based Paint Survey Report Page 3

4.1 Asbestos Containing Materials (>1%)

Asbestos was either detected in concentrations exceeding one percent in the following materials sampled during the asbestos survey or the listed component/materials was presumed to have asbestos, based on limitations of sampling feasibility. Results of the asbestos survey indicated the presence of detectable asbestos in the following materials:

Residence

Material Location Percentage/

Type Approx

Quantity*

NESHAP

Category Condition

Black Penetration Mastic

Roof Penetrations 5%

Chrysotile

80 LF CAT II Good

*Estimated quantities of ACMs listed are provided as a guide to the building owner. The material quantities listed in the table are approximations and TRC is not responsible for the accuracy of the quantities and measurements provided.

4.2 Negative Materials

Samples of the following suspect materials were collected in the locations noted below and were reported with no detectable asbestos, as indicated by laboratory PLM analysis:

Administration Building Negative Materials

Material Sample Locations

Exterior Stucco 12”x12” White with Tan Streaks Vinyl Floor Tile and Yellow Mastic

All Floors (Except Restrooms)

Cove Base and Mastic All Walls (Excluding Restrooms) Sheetrock and Splatter Texture Throughout

2’ x 2’ Ceiling Tile Throughout (Except Restrooms) Sheetrock Jointed (Floated) Wall Storage Area – North Wall

Material Sample Locations

12" x 12" Flower Patterned Vinyl Peel and Stick Floor Tile (Top Layer)

Kitchen and Laundry

9” x 9” Beige Vinyl Floor Tile and Mastic All Floors (Excluding Restrooms) Sheetrock with Smooth Flat Texture Kitchen and Laundry – Walls and Ceilings

Plaster with Smooth Flat Texture Restroom Walls and Ceilings

Sheetrock with Rough Texture All Walls and Ceilings (Except Kitchen and

Laundry) Black / Brown Roofing Roof

Asbestos and Lead-Based Paint Survey Report Page 4

Telecom Building

Material Sample Locations

12” x 12” White Vinyl Floor Tile and Yellow Mastic

Computer Room

Gray Cove Base and Mastic Computer Room Penetration Sealant Roof Penetrations

5.0 Asbestos Recommendations

Results of bulk sample analysis confirmed that asbestos was identified in regulated concentrations within some of the building materials sampled. The ACM was found to be in good condition at the time of the inspection. If damaged ACM is encountered, it should be repaired, encapsulated, or removed as soon as feasible. Access to the damaged ACM by building occupants should be restricted in the areas of damage until abatement response actions can be completed. Such abatement methods should be performed by a qualified/licensed asbestos abatement contractor, and ACM should be handled, stored, and disposed of according to all local, state, and federal regulations.

Persons performing construction or maintenance work in the Site should be aware of the types and locations of ACM and that additional materials (not identified in this report), which are either inaccessible or hidden, may exist at the Site. Care should be used when performing work that disturbs building materials. Any suspect asbestos containing materials uncovered during maintenance, renovation, or demolition activities that are not addressed in this inspection report, or presumed asbestos containing materials (e.g. fire doors with asbestos laden cores), must be sampled by an accredited asbestos inspector prior to disturbance, or they must otherwise be assumed and treated as asbestos containing.

6.0 Lead-Based Paint Inspection

TRC conducted a lead-based paint (LBP) inspection for the determination of LBP and/or lead-based components at the Las Cruces building structures (the “Site”). The LBP inspection was conducted in accordance with the United States Housing and Urban Development (HUD) guidance document, entitled “Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing,” 1997 Revision.

The LBP inspection and testing performed by TRC was limited to building/structures built prior to 1979. For such structures, the general purpose of this investigation was to document the general condition of interior and exterior painted building surfaces, to characterize the composition of painted surfaces with regard to lead content, and to quantify areas/components to define the magnitude to which LBP is present, where encountered. Information derived from this investigation may be used to quantify rough order magnitude costs for abatement of LBP and further refine the scope of LBP abatement activities in support of future procurement activities that will affect LBP. The scope of work associated with this investigation included the following elements:

Identify and focus efforts on buildings built prior to 1979;

Visual inspection of interior and exterior building painted surfaces and components;

Asbestos and Lead-Based Paint Survey Report Page 5

Identify whether coated surfaces were previously sampled during previous survey inspections;

Field testing of painted surfaces and components (if not previously using an X-Ray Fluorescence (XRF) analyzer; and

Assess condition and quantities of LBP for reporting purposes

The lead based paint testing was conducted by Mr. Joe Bohnaker, an EPA, Department of Housing and Urban Development (HUD) trained Lead-Based Paint Building Inspector/Risk Assessor. The inspection was conducted on December 10, 2013.

6.1 Definition of Lead-Based Paint

The United States Department of Housing and Urban Development (HUD), and United States Environmental Protection Agency define lead-based paint as a paint or other surface coatings that contain an amount of lead equal to, or in excess of:

One milligram per square centimeter (1.0 mg/cm2); or One-half of one percent (0.5%) by weight.

6.2 Sampling and Analytical Procedures

All lead-based paint testing was performed using a RMD Model LPA-1B, X-ray Fluorescence (XRF) spectrum analyzer, serial #1124. Assessment activities and XRF testing were performed in accordance with the United States HUD guidance document, entitled “Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing,” 1997 Revision.

The RMD Model LPA-1B XRF uses a 12 milicurie Cobalt 57 sealed radioactive source which has a half life of 18 months. The XRF measures the L & K electron shell energy released by the excited atoms of the test material such as the painted and/or coated surface location to calculate the concentrations of a specific metal on the surface coating down to the substrate. The RMD Model LPA-1B XRF does not have an inconclusive range such as the older generation XRF machines.

At the beginning and end of each work day and at various times during the day, the XRF was calibrated in order to ensure that the instrument was functioning properly. A series of three calibrated readings were obtained using a 1.9 mg/cm2 NIST Paint Film Standard in accordance with the instrument manufacturer’s protocol. In all cases, the instrument was functioning within the standard deviation as defined by the manufacturer and the Performance Characteristic Sheets. All validation readings were recorded in a logbook, which accompanies the instrument. A total of three calibration tests were performed during the course of this investigation.

During this investigation, a total of thirty one (31) painted or coated substrate measurements were obtained using the XRF. The XRF field test data sheets with the results of the paint test measurements are presented in Appendix B-Lead-Based Paint XRF Field Data sheets.

7.0 Summary of Lead-Based Paint Testing Results

The XRF test results indicate that select painted surfaces and building components were found to be containing lead above the United States Department of Housing and Urban Development, and United States Environmental Protection Agency definition of lead-based paint. A summary of paints/coatings determined to be LBP by XRF analysis is provided below:

Asbestos and Lead-Based Paint Survey Report Page 6

Component(s) Color Location(s) Lead XRF

Result (mg/cm²)

Approximate Quantity

Paint Condition

2” x 2” Ceramic Tile Blue Kitchen >9.9 132 SF Intact

2” x 2” Ceramic Tile Blue Bathroom 5.0 70 SF Intact

2” x 2” Ceramic Tile Green Master Bathroom >9.9 42 SF Intact

8.0 Lead-Based Paint Recommendations

Disturbance of lead based paint should be performed by a contractor who has experience and expertise in LBP, abatement, handling and disposal and who can protect the employees of IBWC and the environment from lead exposure hazards. For construction work where an employee may be occupationally exposed to lead in any amount, the workers and contractor must comply with Federal Occupational Safety and Health (OSHA) worker lead exposure regulations 29 CFR

1910.1025 and 1926.62 (lead in construction). Additionally, lead containing waste must be characterized and profiled for proper disposal according to applicable federal State and local regulations.

TRC recommends that interior and exterior painted surfaces containing lead at concentrations greater than or equal to 1.0. mg/cm2 and that are in poor condition be abated and/or stabilized.

Based on the results of this assessment, there were no LBPs identified requiring further action, based on the condition of materials identified at the time of the inspection.

8.1 Lead-Based Paint General Recommendations

Lead is a hazardous substance and its condition, handling and disposal are regulated by Federal, State and local agencies. Lead-containing materials, Lead-based paint, and Lead-Containing Paint generally do not pose a health risk unless the material is disturbed or sufficiently deteriorated to produce dust, which may become airborne and inhaled or ingested. Future site maintenance activities, including surface preparation and painting, may involve practices that could disturb lead-containing materials. The following paragraphs provide a general overview of applicable regulatory standards that relate to the management and/or disposal of lead-based paint:

The Federal Occupational Safety and Health (OSHA) 29 CFR 1910.1025 and 1926.62 (lead in construction) do not provide a definition for “lead-based paint”. Rather, the Lead Construction Standard provides a Permissible Exposure Limit (PEL) for worker exposure to airborne lead particles of 50 micrograms per cubic meter of air (50 µg/m3 for an 8-hour time-weighted average). All employees (workers) and supervisors, who are engaged in lead-related construction activities and shown to be exposed to lead at or above the Permissible Exposure Limit, shall be trained by state-accredited training providers and certified by the Environmental Protection Agency. The OSHA Lead in Construction Standard states that “negative” readings i.e. those below the HUD/EPA definition of what constitutes LBP (1.0 mg/cm2), “DO NOT” relieve contractors from performing exposure assessments (personal exposure monitoring) on their employees per the OSHA Lead Standard, and should not be interpreted as lead is not present.

Although a reading may indicate “negative” result or lead concentration, concentrations

Asbestos and Lead-Based Paint Survey Report Page 7 of airborne lead may still exceed the OSHA Action Level or the OSHA Permissible Exposure Limit (PEL) depending on the work activity.

Future site maintenance activities, including repair, surface preparation and painting, sand/shot blasting, and sanding, in areas where lead-based paint has been identified may result in the liberation of lead at concentrations in excess of the OSHA PEL. TRC recommends the removal and/or stabilization of building materials during planned renovation. Lead-based painted materials should only be removed, handled or stabilized by lead trained personnel in accordance with all applicable federal, state, and local regulations. These requirements include, but are not limited to, the following: Exposure Assessments; Methods of Compliance including work practices, administrative, and engineering controls; Respiratory Protection; Protective Clothing and Equipment;

Housekeeping; Hygiene Facilities; Medical Surveillance; and Employee Information and Training. The waste materials generated must be segregated accordingly and must be subjected to waste characterization testing and disposed of according to applicable regulations.

Lead containing waste must be disposed of in accordance with all applicable federal, state, county or local regulations and guidelines. It is the sole responsibility of the Contractor to assure compliance with all laws and regulations relating to the disposal.

The abatement contractor should comply with the requirements of the Resource Conservation and Recovery Act (RCRA). Waste materials shall be segregated into separate waste streams (i.e. paint chips, personal protective equipment, plastic, etc.) and placed into labeled, leak-tight containers. Wastewater from the washing facilities should be captured, filtered, and sampled for lead content prior to disposal into the sanitary sewer system. Additional details regarding waste characterization sampling and analysis are provided in the following section.

9.0 DISCLAIMER

The content presented in this report is based on data collected during the site inspection and survey, review of pertinent regulations, requirements, guidelines and commonly followed industry standards, and information provided (if any) by the property owner, their clients, agents, and representatives.

The work has been conducted in an objective and unbiased manner and in accordance with generally accepted professional practice for this type of work. TRC believes the data and analysis to be accurate and relevant, but cannot accept responsibility for the accuracy or completeness of available documentation or possible withholding of information of other parties. Structures or components thereof surveyed may contain hidden surfaces or materials requiring destructive access to inspect and/or sample. It is possible that additional materials could be discovered during destructive or demolition activities. In the event additional materials (not identified herein) are discovered during such activities, additional investigation and sampling may be necessary.

This asbestos survey and lead-based paint inspection report is designed to aid the property owner, architect, construction manager, general contractor, and asbestos or LBP abatement contractor in locating ACM and/or LBP . This report is not intended for, and may not be utilized as, a bidding document or as an abatement project specification document.

Asbestos and Lead-Based Paint Survey Report Page 8

10.0 SIGNATORY

This asbestos and lead-based paint survey was conducted by a qualified, trained professional, experienced in the inspection and survey for asbestos containing materials and lead-based paint in building structures and associated components thereof. If there are any questions concerning information contained in this report, you may contact one of the undersigned in our Irvine, California office at 949.727.9336.

Sincerely, TRC Environmental Corporation

Karen Terry, CIH Douglas W. Coburn, CAC, REA Senior Project Manager Senior Project Manager

Tables

Homogeneous Materials Table

TABLES – HOMOGENOUS MATERIALS SUMMARY

International Boundary & Water Commission – Las Cruces, NM Page 1

Building Name Sample Numbers Material Material Location(s) Analytical

Results Approx

Quantity

NESHAP

Category

Administration Building

LCADM-01 to

LCADM-03

12” x 12” White with Tan Streaks Vinyl Floor Tile and Yellow Mastic

All Admin Floors (excluding Restrooms)

ND 830 SF NA

Administration Building

LCADM-04 to

LCADM-06

Cove Base and Mastic All Admin Walls

(excluding Restrooms)

ND 250 LF NA

Administration Building

LCADM-07 to

LCADM-09

Sheetrock and Splatter Texture Throughout ND 2,700 SF NA

Administration Building

LCADM-10 to

LCADM-12

Sheetrock Jointed (Floated) Wall Storage – North Wall ND 200 SF NA

Administration Building

LCADM-13 t0

LCADM-15

2’ x 4’ Ceiling Panel All Admin Ceilings

(excluding Restrooms)

ND 830 SF NA

Results Approx

Quantity

NESHAP

Category

Residence

LCRES-01

through

LCRES-03

9” x 9” Beige Vinyl Floor Tile and Mastic

All Floors (excluding Restrooms)

ND 1,180 SF NA

Residence

LCRES-04

through

LCRES-06

12” x 12” Flower Patterned Vinyl Peel and Stick Floor Tile (Top

Layer) Kitchen and Laundry ND 210 SF NA

Residence

LCRES-07

through

LCRES-09

Sheetrock with Smooth Flat Texture Kitchen and Laundry Walls and Ceilings

ND 910 SF NA

Residence

LCRES-10

through

LCRES-12

Plaster with Smooth Flat Texture Restroom Walls and

Ceilings

ND 480 SF NA

Residence

LCRES-13

through

LCRES-15

Sheetrock with Rough Texture All Walls and Ceilings (excluding Restrooms, Kitchen and Laundry)

ND 3,700 SF NA

TABLES – HOMOGENOUS MATERIALS SUMMARY

International Boundary & Water Commission – Las Cruces, NM Page 2

Building Name Sample Numbers Material Material Location(s) Analytical

Results Approx

Quantity

NESHAP

Category

Residence

LCRES-16

through

LCRES-18

Black / Brown Roofing Roof ND 1,900 SF NA

Residence

LCRES-19

through

LCRES-21

Black Penetration Sealant Roof Penetrations 5%

Chrysotile 80 LF Cat II

Results Approx

Quantity

NESHAP

Category

Communication Building

LCCOM-01

through

LCCOM-03

12” x 12” White Vinyl Floor Tile and Yellow Mastic

Computer Room ND 77 SF NA

Communication Building

LCCOM-04

through

LCCOM-06

Gray Cove Base and Mastic Computer Room ND 36 LF NA

Communication Building

LCCOM-07

through

LCCOM-09

Penetration Sealant Roof Penetrations ND 2 LF NA

Table Key

ND – None Detected NA – Not Applicable SF – Square Feet LF – Linear Feet Cu Ft – Cubic Feet Cat I – Category I Non-Friable Asbestos Containing Material Cat II - Category II Non-Friable Asbestos Containing Material RACM – Regulated Asbestos Containing Material (Friable) ACM – Asbestos Containing Material; Contains greater than 1% asbestos by weight NESHAP – National Emissions Standards for Hazardous Air Pollutants (EPA asbestos regulation)

Appendix A

Bulk Asbestos Sample Laboratory Analytical Report

And Chain of Custody

Industrial Hygiene Laboratory 21 Griffin Road North Windsor, CT 06095

(860) 298-6308

43347.IBWC.doc

Lab Log #: 0043347

Las Cruces, Admin. Building

CLIENT: International Boundary & Water Commission

Site:

Date Analyzed:

Date Received:

12/13/2013

12/12/2013

Project #: 209058.0000.0000

BULK ASBESTOS ANALYSIS REPORT

Layer No. Asbestos Type

Other Matrix MaterialsSample No. Homogenous

Asbestos

POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116

Color Multi-

Layered

- - - None1LCADM-01 NDNo YesTan (mastic)

- - - None2LCADM-01 NDNo YesWhite (tile)

- - - None1LCADM-02 NDNo YesTan (mastic)

- - - None2LCADM-02 NDNo YesWhite (tile)

- - - None1LCADM-03 NDNo YesTan (mastic)

- - - None2LCADM-03 NDNo YesWhite (tile)

- - - None1LCADM-04 NDNo YesCream (mastic)

- - - None2LCADM-04 NDNo YesPink (cove base)

- - - None1LCADM-05 NDNo YesCream (mastic)

- - - None2LCADM-05 NDNo YesPink (cove base)

- - - None1LCADM-06 NDNo YesCream (mastic)

- - - None2LCADM-06 NDNo YesPink (cove base)

- - - None1LCADM-07 NDNo YesWhite (joint compound)

- - - None2LCADM-07 NDNo YesLight Pink (drywall)

- - - None1LCADM-08 NDNo YesWhite (joint compound)

- - - None2LCADM-08 NDNo YesLight Pink (drywall)

- - - None1LCADM-09 NDNo YesWhite (joint compound)

- - - None2LCADM-09 NDNo YesLight Pink (drywall)

- - - None1LCADM-10 NDNo YesWhite (joint compound)

- - - None2LCADM-10 NDNo YesLight Pink (drywall)

TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS

NVLAP Lab Code 101424-0

RI #AAL-007C3 TX #300354

AIHA #100122

VT #AL014538

CT #PH-0426

VA #3333 000283

NY #10980

NJ #CT004

WV# LT000356

CA #10275CA

ME LA-0075, LB-0071

AZ #A20944

MA #AA000052

HI #L-09-004

21 Griffin Road North Windsor, CT 06095

(860) 298-6308

43347.IBWC.doc

Layer No. Asbestos Type

Other Matrix MaterialsSample No. Homogenous

Asbestos

POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116

Color Multi-

Layered

- - - None1LCADM-11 NDNo YesWhite (joint compound)

- - - None2LCADM-11 NDNo YesLight Pink (drywall)

- - - None1LCADM-12 NDNo YesWhite (joint compound)

- - - None2LCADM-12 NDNo YesLight Pink (drywall) cellulose mineral wool

None- -LCADM-13 ND40% 40%

Yes NoWhite/Grey cellulose mineral wool

None- -LCADM-14 ND40% 40%

Yes NoWhite/Grey cellulose mineral wool

None- -LCADM-15 ND40% 40%

Yes NoWhite/Grey

Reporting limit- asbestos present at 1%

Trace - asbestos was observed at level of less than 1% NA/PS - Not Analyzed / Positive Stop

The Laboratory at TRC follows the EPA's Interim Method for the Determination of Asbestos in Bulk Insulation (1982), and the EPA recommended Method for the Determination of Asbestos in Bulk Building Materials (EPA/600/R-93/116), July 1993, R.L. Perkins and B.W. Harvey which utilizes polarized light microscopy (PLM). Our analysts have completed an accredited course in asbestos identification. TRC's Laboratory is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), for Bulk Asbestos Fiber Analysis, NVLAP Code 18/A01, effective through June 30, 2014.

TRC is an American Industrial Hygiene Association (AIHA) accredited lab for PLM effective through October 1, 2014. Asbestos content is determined by visual estimate unless otherwise indicated. Quality Control is performed in-house on at least 10% of samples and the QC data related to the samples is available upon written request from the client.

This report shall not be reproduced, except in full, without the written approval of TRC. This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report relates only to the items tested.

ND - asbestos was not detected

Note: Polarized-light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. In those cases, negative results must be confirmed by quantitative transmission electron microscopy.

Analyzed by: Reviewed by: Date Issued

12/13/2013Kathleen Williamson, Laboratory Manager Amanda Parkins, Approved Signatory

TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS

NVLAP Lab Code 101424-0

RI #AAL-007C3 TX #300354

AIHA #100122

VT #AL014538

CT #PH-0426

VA #3333 000283

NY #10980

NJ #CT004

WV# LT000356

CA #10275CA

ME LA-0075, LB-0071

AZ #A20944

21 Griffin Road North Windsor, CT 06095

(860) 298-6308

43348.IBWC.doc

Lab Log #: 0043348

Las Cruces- Residence

CLIENT: International Boundary & Water Commission

Site:

Date Analyzed:

Date Received:

12/13/2013

12/12/2013

Project #: 209058.0000.0000

BULK ASBESTOS ANALYSIS REPORT

Layer No. Asbestos Type

Other Matrix MaterialsSample No. Homogenous

Asbestos

POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116

Color Multi-

Layered

- - - None1LCRES-01 NDNo YesBrown (mastic)

- - - None2LCRES-01 NDNo YesBeige (tile)

- - - None1LCRES-02 NDNo YesBrown (mastic)

- - - None2LCRES-02 NDNo YesBeige (tile)

- - - None1LCRES-03 NDNo YesBrown (mastic)

- - - None2LCRES-03 NDNo YesBeige (tile)

- - - None- -LCRES-04 NDYes NoWhite/Light Grey

- - - None- -LCRES-05 NDYes NoWhite/Light Grey

- - - None- -LCRES-06 NDYes NoWhite/Light Grey

- - - None- -LCRES-07 NDYes NoBeige

- - - None- -LCRES-08 NDYes NoBeige

- - - None- -LCRES-09 NDYes NoBeige

- - - None- -LCRES-10 NDYes NoBeige

- - - None- -LCRES-11 NDYes NoBeige

- - - None- -LCRES-12 NDYes NoBeige

- - - None- -LCRES-13 NDYes NoBeige

- - - None- -LCRES-14 NDYes NoBeige

- - - None- -LCRES-15 NDYes NoBeige fibrous glass None- -LCRES-16 ND10%Yes NoBlack/Brown

TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS

NVLAP Lab Code 101424-0

RI #AAL-007C3 TX #300354

AIHA #100122

VT #AL014538

CT #PH-0426

VA #3333 000283

NY #10980

NJ #CT004

WV# LT000356

CA #10275CA

ME LA-0075, LB-0071

AZ #A20944

21 Griffin Road North Windsor, CT 06095

(860) 298-6308

43348.IBWC.doc

Layer No. Asbestos Type

Other Matrix MaterialsSample No. Homogenous

Asbestos

POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116

Color Multi-

Layered fibrous glass None- -LCRES-17 ND10%Yes NoBlack/Brown fibrous glass None- -LCRES-18 ND10%Yes NoBlack/Brown

- - - Chrysotile- -LCRES-19 5%Yes NoBlack

- - - -- -LCRES-20 NA/PS- - - -- -

- - - -- -LCRES-21 NA/PS- - - -- -

Reporting limit- asbestos present at 1%

Trace - asbestos was observed at level of less than 1% NA/PS - Not Analyzed / Positive Stop

The Laboratory at TRC follows the EPA's Interim Method for the Determination of Asbestos in Bulk Insulation (1982), and the EPA recommended Method for the Determination of Asbestos in Bulk Building Materials (EPA/600/R-93/116), July 1993, R.L. Perkins and B.W. Harvey which utilizes polarized light microscopy (PLM). Our analysts have completed an accredited course in asbestos identification. TRC's Laboratory is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), for Bulk Asbestos Fiber Analysis, NVLAP Code 18/A01, effective through June 30, 2014.

TRC is an American Industrial Hygiene Association (AIHA) accredited lab for PLM effective through October 1, 2014. Asbestos content is determined by visual estimate unless otherwise indicated. Quality Control is performed in-house on at least 10% of samples and the QC data related to the samples is available upon written request from the client.

This report shall not be reproduced, except in full, without the written approval of TRC. This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report relates only to the items tested.

ND - asbestos was not detected

Note: Polarized-light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. In those cases, negative results must be confirmed by quantitative transmission electron microscopy.

Analyzed by: Reviewed by: Date Issued

12/16/2013Kathleen Williamson, Laboratory Manager Amanda Parkins, Approved Signatory

TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS

NVLAP Lab Code 101424-0

RI #AAL-007C3 TX #300354

AIHA #100122

VT #AL014538

CT #PH-0426

VA #3333 000283

NY #10980

NJ #CT004

WV# LT000356

CA #10275CA

ME LA-0075, LB-0071

AZ #A20944

21 Griffin Road North Windsor, CT 06095

(860) 298-6308

43349.IBWC.doc

Lab Log #: 0043349

Las Cruces- Communications Building, Las Cruces, NM

CLIENT: International Boundary & Water Commission

Site:

Date Analyzed:

Date Received:

12/13/2013

12/12/2013

Project #: 209058.0000.0000

BULK ASBESTOS ANALYSIS REPORT

Layer No. Asbestos Type

Other Matrix MaterialsSample No. Homogenous

Asbestos

POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116

Color Multi-

Layered

- - - None1LCCOM-01 NDNo YesYellow (mastic)

- - - None2LCCOM-01 NDNo YesWhite (tile)

- - - None1LCCOM-02 NDNo YesYellow (mastic)

- - - None2LCCOM-02 NDNo YesWhite (tile)

- - - None1LCCOM-03 NDNo YesYellow (mastic)

- - - None2LCCOM-03 NDNo YesWhite (tile)

- - - None1LCCOM-04 NDNo YesYellow (mastic)

- - - None2LCCOM-04 NDNo YesGrey (cove base)

- - - None1LCCOM-05 NDNo YesYellow (mastic)

- - - None2LCCOM-05 NDNo YesGrey (cove base)

- - - None1LCCOM-06 NDNo YesYellow (mastic)

- - - None2LCCOM-06 NDNo YesGrey (cove base)

- - - None- -LCCOM-07 NDYes NoWhite

- - - None- -LCCOM-08 NDYes NoWhite

- - - None- -LCCOM-09 NDYes NoWhite

TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS

NVLAP Lab Code 101424-0

RI #AAL-007C3 TX #300354

AIHA #100122

VT #AL014538

CT #PH-0426

VA #3333 000283

NY #10980

NJ #CT004

WV# LT000356

CA #10275CA

ME LA-0075, LB-0071

AZ #A20944

21 Griffin Road North Windsor, CT 06095

(860) 298-6308

43349.IBWC.doc

Layer No. Asbestos Type

Other Matrix MaterialsSample No. Homogenous

Asbestos

POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116

Color Multi-

Layered

Reporting limit- asbestos present at 1%

Trace - asbestos was observed at level of less than 1% NA/PS - Not Analyzed / Positive Stop

The Laboratory at TRC follows the EPA's Interim Method for the Determination of Asbestos in Bulk Insulation (1982), and the EPA recommended Method for the Determination of Asbestos in Bulk Building Materials (EPA/600/R-93/116), July 1993, R.L. Perkins and B.W. Harvey which utilizes polarized light microscopy (PLM). Our analysts have completed an accredited course in asbestos identification. TRC's Laboratory is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), for Bulk Asbestos Fiber Analysis, NVLAP Code 18/A01, effective through June 30, 2014.

TRC is an American Industrial Hygiene Association (AIHA) accredited lab for PLM effective through October 1, 2014. Asbestos content is determined by visual estimate unless otherwise indicated. Quality Control is performed in-house on at least 10% of samples and the QC data related to the samples is available upon written request from the client.

This report shall not be reproduced, except in full, without the written approval of TRC. This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report relates only to the items tested.

ND - asbestos was not detected

Note: Polarized-light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. In those cases, negative results must be confirmed by quantitative transmission electron microscopy.

Analyzed by: Reviewed by: Date Issued

12/13/2013Kathleen Williamson, Laboratory Manager Amanda Parkins, Approved Signatory

TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS

NVLAP Lab Code 101424-0

RI #AAL-007C3 TX #300354

AIHA #100122

VT #AL014538

CT #PH-0426

VA #3333 000283

NY #10980

NJ #CT004

WV# LT000356

CA #10275CA

ME LA-0075, LB-0071

AZ #A20944

Appendix B

Lead-Based Paint XRF Field Data Sheets

Appendix C

Sample Location Drawings

Appendix D

Photographs

USIBWC – Las Cruces Yard - Residence Collected December 10, 2013

Suspect Materials Photographs

Photo #1: View of Project Residence, Brick Masonry on Concrete Slab

Photo #2: 9”x9” Beige Vinyl Composite Floor Tile and Mastic

Photo #3: 12”x12” Flower/Patterned Floor Tile (Stick-On)

Photo #4: Smooth Textured Sheetrock System in Kitchen and Laundry Rooms

Photo #5: Smooth Textured Sheetrock Wall & Ceiling System in Restroom

Photo #6: Rough Textured Sheetrock Wall System

Photo #7: Residence Floor Carpet Mastic Photo #8: Residence Asphalt Roof Shings and Penetration Mastic

Photo #9: AM Recording Building Photo #10: Administrative Building

Photo #11: Administrative Building ‐ 12” x 12”

Vinyl Floor Tile

Photo #12: Administrative Building – 2’x4’ Ceiling

Panels

Photo #13: Administrative Building ‐ Sheetrock Photo #14: Administrative Building – Wall Texture

Photo #15: Paint Shed Photo #16: Parking Shed

Photo #17: Storage Shed Photo #18: Telecom Building

Photo #19: Telecom Building – 12”x12” Vinyl Floor Tile and Cove Base

Photo #20: Telecom Building – Vinyl Flooring

Photo #21: Telecom Building – Vinyl Reinforced

Plastic and Concrete Walls

Photo #22: Telecom Building – Penetrating

Mastic

Appendix E

Inspector Certifications

Binder1 Las Cruces
USIBWC Las Cruces Asb + Lead Survey Report Draft (DWC)
USIBWC Las Cruces Asb + Lead Survey Report Draft (DWC)
Appendix A Labs combined
0043347-IBWC.pdf
43347.IBWC CoC
0043348-IBWC
43348.IBWC CoC
0043349-IBWC
43349.IBWC CoC
USIBWC Las Cruces Asb + Lead Survey Report Draft (DWC)
Appendix B Las Cruces XRF Data
USIBWC Las Cruces Asb + Lead Survey Report Draft (DWC)
Appendix C Las Cruces Residences Drawings
USIBWC Las Cruces Asb + Lead Survey Report Draft (DWC)
Appendix D Photo Pages_Las Cruces
USIBWC Las Cruces Asb + Lead Survey Report Draft (DWC)
Attachment E - Certs
Attachment E - Certs
Doug Coburn TX asb consultant.pdf
Joe Bohnaker certs

Joe B LBP Insp Cert

IBWC_Las Cruces, NM_Table_Summary of Homo Matls Results
Binder1 Las Cruces
USIBWC Las Cruces Asb + Lead Survey Report Draft (DWC)
USIBWC Las Cruces Asb + Lead Survey Report Draft (DWC)
Appendix A Labs combined
0043347-IBWC.pdf
43347.IBWC CoC
0043348-IBWC
43348.IBWC CoC
0043349-IBWC
43349.IBWC CoC
USIBWC Las Cruces Asb + Lead Survey Report Draft (DWC)
Appendix B Las Cruces XRF Data
USIBWC Las Cruces Asb + Lead Survey Report Draft (DWC)
Appendix C Las Cruces Residences Drawings
USIBWC Las Cruces Asb + Lead Survey Report Draft (DWC)