KU-10001-2J_Drawing.pdf
PDF 4 MB Posted
- Solicitation number
- W90VN923R0050
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W90VN923R0050.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
R-11SHEET OF
DESIGNED BY
CHECKED BY
SUBMITTED BY
APPROVED BY
PROJECT NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
O & M
HOUSING DIV.
REVIEWED BY
UNITED STATES ARMY GARRISON DAEGU
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
DIRECTORATE OF PUBLIC WORK
HGFEDCBA
D - 23 - 03
CHON, HYON TAE
DESIGN REVIEW SIGNATURE
ORGANIZATION
USING AGENCY
36TH SIGNAL
MASTER PLN.
ENVIRONMENTAL
NAME SIGNATURE
O&M DIV.
FIRE DEPT.
SAFETY OFFICE
DPTMS(AT/FP)
188TH MP COM.
IND. HYGENIST
UNIT #15746, APO AP 96218-5746
DRAWING NO.
CHIEF,
DESIGN & TECH. REVIEW Br.
AS SHOWN
1 1 OF 1R - 1
T I T L E S H E E T
TITLE SHEET
C - 12
C - 23
C - 34
C - 45
USING AGENCY
C - 56
DATE:27 DEC 22
C - 67
C - 78
C - 89
C - 910
CIVIL
LOCATION PLAN
C - 1011 10 OF 13
C - 1112 11 OF 13
C - 1213 12 OF 13
C - 1314 13 OF 13
SITE LAYOUT PLAN
PCC PAVEMENT LAYOUT PLAN
KU-10001-2J
PROJECT NO. KU-10001-2J, SALEM SITE
REPLACE EXISTING HELIPAD, H-609
REPLACE EXISTING HELIPAD, H-609
SALEM SITE
REMOVAL PLAN
OVERALL SITE FENCING AND MARKER PLAN
HELIPAD PAVEMENT MARKING PLAN AND DETAILS
RETAINING WALL PLAN
TYPICAL SECTIONS
CHAINLINK FENCE PROFILE
PCC PAVEMENT DETAILS
TYPICAL RETAINING WALL DETAILS
DETAILS
MOORING POINT DEVICE AND STATIC GROUND DETAILS
S /P
P U
M P
F U
E L
9.00
1.00
0.40
N
H-60
H-609
S-2200 S-2102
S
0S-2207
THIS PROJECT
2-
3-
1SEE SITE PLANS
SITE BOUNDARY LINE
KU, HUN MO
CIVIL
AS SHOWN
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
CHI, K. K.
GRAPHIC SCALE
0- 2000010000
SCALE: 1 : 500
SCALE : 1 / 500
LOCATION PLAN
D - 23 - 03
LOCATION PLAN
REPLACE EXISTING HELIPAD, H-609
SALEM SITE
C-1
1 13
KU-10001-2J
27 DEC 22
VICINITY MAP
N0T TO SCALE
KWANGJU
WAEGWAN
TAEJON
KIMHAE
PUSAN
CHINHAE
YECHON
WONJU
SONGTAN
KANGNUNG
SAMCHOK
SEOUL
MUNSAN
UIJONGBU
INCHON
SUWON
POHANG
KYONGJU
KUNSAN
TONGDUCHON
SOKCHO
HOENGSONG
PYONGTAEK
D
M
CHUNCHON
WEST SEA
TONGYOUNG
CHUNGJU
MOKPO
SEA
EASTERN
Z
N
SALEM SITE
GUMI
DAEGU
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
N
SCALE : 1 / 150
GRAPHIC SCALE
SCALE: 1 : 150
3000 60002-
S/P
G
R A
N
IT
E
S T E P S
~OPEN DITCH~
IF REQUIRED.
DETOUR ROAD FOR VEHICLES DURING CONSTRUCTION PERIOD
5. CONTRACTOR SHOULD PROVIDE TEMPORARY ACCESS ROAD AND
ON THE PROJECT.
BY THE CONTRACTING OFFICER PRIOR TO COMMENCING WORK
PORTION OF THE JOB BY THE COR AND SHOULD BE APPROVED
2. THE CONTRACTOR SHOULD SUBMIT SHOP DRAWINGS FOR ANY
CONTRACTING OFFICER.
CONTRACTORS EXPENSE TO THE SATISFACTION OF THE
DAMAGED BY DISMANTLING, DEMOLISHING, OR REMOVING AT THE
RESTORATION TO THEIR ORIGINAL CONDITIONS OF THE ITEMS
3. THE CONTRACTOR SHOULD BE RESPONSIBLE FOR REPAIR/
AND OTHER UTILITY MARKERS IN THE PROJECT LIMIT.
6. CONTRACTOR SHALL RESTORE/REESTABLISH SURVEY MONUMENTS
FROST DEPTH UNLESS OTHERWISE NOTED.
8. WATER AND SEWER LINE SHOULD HAVE A MINIMUM COVER OF
WITHOUT ANY ADDITIONAL COST.
INCLUDING FALSEWORK SUCH AS FORMWORKS AND SHORING
9. CONTRACTOR SHOULD PROVIDE ANY NECESSARY RESOURCES
APPROVAL PRIOR TO COMMENCING THE WORK.
SUBMITTAL TO THE DESIGN AND TECHNICAL REVIEW BRANCH FOR
THE CONTRACTOR SHOULD PREPARE AND SUBMIT MATERIAL
MILLIMETERS AND STATIONS AND ELEVATIONS ARE IN METERS.
UNLESS OTHERWISE NOTED ALL THE DIMENSIONS ARE IN
SOLID SODDING WITHIN THE WORK BOUNDARY.
CUT AND FILLED AREA SHALL BE COVERED WITH TOP SOIL AND
14.
13.
10.
11.
12.
15.
16.
SUBMISSION OF CONTRACT PROPOSAL.
AND DIMENSIONS AT THE PROJECT SITE ORIENTATION PRIOR TO
1. THE CONTRACTOR SHOULD VERIFY ALL EXISTING CONDITIONS
CONSTRUCTION OPERATIONS.
AND OTHER ITEMS WHICH WILL INTERFERE WITH THE
SUCH AS UNDERGROUND ROCK BASE, EXISTING UTILITY LINES,
AND CLEARED/REROUTED OF ALL NATURAL OBSTRUCTIONS,
4. THE SITE INDICATED ON THE DRAWING SHOULD BE GRADED
WILL BE UTILIZED TO ACCOMPLISH THE CIVIL SCOPE OF WORK.
COMMAND" FORM AS A PART OF THIS PROJECT.THE DETAILS
DEPARTMENT OF THE ARMY INSTALLATION MANAGEMENT
O & MA PROJECT, KOREA, REVISION1, 30 OCTOBER 2015,
COMMAND" AND "STANDARD TECHNICAL SPECIFICATIONS FOR
2015, DEPARTMENT OF THE ARMY INSTALLATION MANAGEMENT
DETAIL DRAWINGS, FOR O & MA PROJECT, KOREA, 30 NOVEMBER
7. THE CIVIL STANDARD DRAWINGS SHOWN IN THE "STANDARD
PROVIDED FOR THE CONTRACTOR BY THE GOVERNMENT.
CONSTRUCTION AREA AND NO LAY DOWN AREA SHALL BE
OFFICES AND STORAGE AREAS SHALL BE WITHIN THE
LOCATION APPROVED/INDICATED BY C.O.R. ADMINISTRATIVE FIELD
TEMPORARY FACILITIES ACCORDING TO O&MA SPEC. AT THE
CONTRACTOR SHOULD PROVIDE AND MAINTAIN THE CONTRACTOR’S
THE PUBLIC AND/OR MILITARY TRAFFIC AND OPERATIONS.
NECESSARY PRECAUTIONS FOR THE PROTECTION AND SAFETY OF
AND OTHER PROTECTIVE FACILITIES AND SHALL TAKE ALL
NECESSARY SIGNS, LIGHTS, FLARES, BARRICADES, MARKERS, CONES
CONTRACTOR SHALL PROVIDE, INSTALL AND MAINTAIN ALL
LAWS AND REGULATIONS.
GOVERNMENT LEASED PROPERTY IN ACCORDANCE WITH LOCAL
DISPOSAL OF WASTE MATERIALS SHOULD BE OUTSIDE U.S.
DETERMINE PROPER MATERIAL HANDING METHODS.
MATERIALS WITHIN PROJECT LIMIT WITH COR CAREFULLY TO
CONTRACTOR SHOULD COORDINATE ANY SALVAGEABLE/RECYCLABLE
GENERAL NOTES:
REMOVE EXISTING TREES AND SHRUBS
EXISTING HELIPAD TO BE REPLACED
AND SHRUBS
REMOVE EXISTING TREES
PROJECT WORK LIMITS
REMOVAL PLAN
TO BE REPLACED
EXISTING CONCRETE OPEN DITCH
REMOVAL NOTES
1.ALL REMOVAL WORKS SHALL BE CONFINED WITHIN THE PROJECT LIMITS INDICATED, UNLESS OTHERWISE NOTED.
THE ITEMS WITHIN THE PROJECT BOUNDARY SHALL BE REMOVED AS INDICATED AND REQUIRED.2.
3.
STANDARDS FOR KOREA, USFK PAM 200-1.
ALL DISPOSAL WORK SHALL BE IN ACCORDANCE WITH THE APPLICABLE KOREAN ENVIRONMENTAL GOVERNING4.
(DUST REDUCTION REQUIREMENTS).
CONTRACTOR SHALL PERFORM THE WORKS IN ACCORDANCE WITH THE USFK REGULATION 201-1, TABLE 2-76.
7.
OF THE CONTRACTIING OFFICER.
DAMAGED BY DISMANTLING, DEMOLISHING OR REMOVING AT THE CONTRACTORS EXPENSE TO THE SATISFACTION CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR/ RESTORATION TO THEIR ORIGINAL CONDITIONS OF THE ITEMS
WITH THE GUIDANCE OF COR.
ALL SALVAGEABLE MATERIALS SHALL BE CLEANED AND RETURNED TO USING AGENCIES AND DPW IN ACCORDANCE
FOR THE PROJECT LIMITS, I.E. EDGE OF PAVEMENT, EDGE OF ROADWAY, EXISTING CHAIN-LINK FENCE, ETC.
REMOVAL WORK LIMITS SHOWN ARE APPROXIMATE, EXISTING GROUND FEATURES SHALL BE USED AS DEMARCATIONS
8.
9.
ALL TREES, SHRUBS, ROCKS AND BOULDERS SHALL BE REMOVED IN THE PROJECT WORK LIMITS.
SITE BOUNDARY LINE
TO BE REPLACED
EXISTING RETAINING WALL
BPAD
BPAD
BPAD
BWALL
BWALL
DIT
DIT
DIT
DIT
DIT
DITDIT
DIT
DIT
DIT
DIT
DIT
DIT
DIT
DIT
GL
GL
GL
GL
GL
GL
GL
GL
GL
GL
GL
GL
GL
GL
GL
GLGL
GL
GL
GL
GL
GL
GL
GL
GL
GL
GL
GL
GL
GL
GL
MARK
MARK
MARK
MARK
MARK
MARK
MARK
MARK
MARK
MARK
MARK
MARK
MARK
MARK
MARK
MARK
MARK
MARK
MARK
MARK
MARKMARK
MARK
MARK
MEMOMEMO
MHMH
MH
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PADPAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD
PAD PAD
PAD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
ROCKROCK
ROCK
ROCK
ROCK
ROCK
ROCK
ROCK
RWALL
RWALL
RWALL
RWALL
RWALL RWALL RWALL
RWALL
RWALL
RWALL
RWALL
RWALL
RWALL
RWALL
RWALL
RWALL
RWALL
RWALL
SB
SH
SH
SH
TR
TR
TR
TR
TR
TR
TR
TR
TR
~ROAD~
938.306
938.246 936.686
938.436 938.506
938.756
938.916
937.676
938.866
938.896
938.546 938.976
939.086
939.066
939.136
939.066
939.266
939.196
937.286
939.056
939.086
939.056
939.146
938.536
938.686
939.006
939.176 938.906
937.976
937.946
938.026
937.866
938.336
938.506 938.476
938.826
938.836 937.156
939.086
939.276
938.226
939.316
939.296
938.686
938.746
938.956
939.436
939.446
939.406
939.016
938.906
937.806
937.026
936.986
937.456
937.396
937.546
938.136
939.016
939.396939.376
939.376
939.396
939.536
939.516
939.496
939.536
939.436
939.246
939.086
939.036
938.816
938.946
938.916
938.826
938.976
939.076
939.396 939.416
939.426
939.396
939.246 939.566
939.556
940.006
940.436
940.446
939.886
939.596
939.556
939.586
939.446939.436
939.426
939.446
939.616
939.506
939.526 939.586
939.636
939.586 939.586
939.656
939.606939.596 939.566
939.626
939.626
939.636
939.556
939.526
939.526 939.566
939.496
939.206
939.396
939.336
939.546
939.536
939.666
939.746
940.736
940.186
939.926
939.706 939.676
939.676
940.176940.196
940.236
939.936
940.536940.446
939.886
939.936
939.606
939.596
939.296
938.916
939.536
939.356 939.106
939.516
939.096
939.416939.136
938.616
939.396
938.156
939.266
939.296
939.266
937.686
939.036938.976
938.656
938.306
938.946
939.236
939.256
939.316
939.286
939.266
939.326 939.376
939.386
939.356 939.376
939.386
939.376
939.356
939.396
939.386
939.466
939.456
939.476
939.446
939.526
939.546
939.556
939.576 939.586
939.576
939.596
939.596
939.586
939.596
939.656
939.636
939.626
939.626
939.286
938.866
938.976
939.356
939.296
939.606939.546
WITH LOCAL LOWS AND REGULATIONS.
DISPOSAL OF WASTE MATERIALS AND CONSTRUCTION DEBRIS SHALL BE REMOVED/ DISPOSED IN ACCORDANCE CONTRACTOR SHALL CARRY DOWN THE WASTE MATERIALS AND OTHER CONSTRUCTION DEBRIS ON SITE. AND5.
KU, HUN MO
CHI, K. K.
27 DEC 22
REPLACE EXISTING HELIPAD, H-609
SALEM SITE
CIVIL
REMOVAL PLAN
KU-10001-2J D - 23 - 03
2 13 C-2
AS SHOWN
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SCALE : 1 / 150
GRAPHIC SCALE
SCALE: 1 : 150
3000 6000
SITE LAYOUT PLAN
3-
MEMO
MH
MH
PAD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD ROCK
ROCK
ROCK
SB
TR
TR
TR
TR
TR
S/P
G
R A
N
IT
E
S T E P S
~ROAD~
EXISTING MONUMENT
6-
10-
7-
5-
1SEE DETAIL
PAINT HELIPAD PAVEMENT MARKINGS
SEE THE SECTIONS, PLANS, AND DETAILS
REPLACE EXISTING HELIPAD, (34,000 X 30,000)
PROJECT WORK LIMITS
SEE O&MA SEPCIFICATIONS SECTION 31 00 00
(PROJECT WORK LIMIT)
COMPACT SUBGRADE AND FINISH GRADE
PROVIDE DRAIN LINE, (PVC, VG1, D=300)
S T
SEE THE NOTES
SOD WITH TOP SOIL AND SOLID SODDING
EL.=939.545
E 436942.544 N 3994472.809
HELIPAD CORNER#1
EL.=939.545
E 436971.160 N 3994491.169
HELIPAD CORNER#4
EL.=939.845
E 436926.344 N 3994498.059
HELIPAD CORNER#2
EL.=939.845
E 436954.961 N 3994516.419
HELIPAD CORNER#3
EL.=939.770
EL.=939.695
EL.=939.620
EL.=939.545
S
1.
M
IN
EL.=939.620
EL.=939.845
EL.=939.770EL.=939.770
EL.=939.620
EL.=939.695 EL.=939.695S
1.
12-
12- 21.
NOTES:
FINISH SURFACE SHALL BE WELL GRADED AND HAVE POSITIVE DRAINAGE SURFACE.2.
SCOPE OF WORK
9.
1.
SEE GENERAL NOTES ON DRAWING REF. NO. C-2.
SEE REMOVAL NOTES ON DRAWING REF. NO. C-2.
1.
2.
3.SEE NOTES ON DRAWING REF. NO. C-3.
PAINT HELIPAD PAVEMENT MARKINGS.
REPLACE EXISTING HELIPAD, (34,000 X 30,000) WITH NEW.
2.
3.
8.
REMOVE EXISTING TREES AND SHRUBS.
AND ETC.
PROVIDE EARTH WORKS INCLUDING EXCAVATION, COMPACTION
PROVIDE DRAIN LINE, (PVC, VG1, D=300)
GRATING COVERED CONCRETE DITCH.
REPLACE EXISTING CONCRETE OPEN DITCH WITH NEW STEEL
5.
6.
SOD WITH TOP SOIL AND SOLID SODDING.
-"MILYANG" N:3927566.782 E:476775.02 (KOREA NCP; APS)
-"GPS28" N:3984488.078 E:323979.255 (CP CARROLL FED BRASS DISK)
-"2" N:3994356.180 E:436974.982 (X-MARKED)
-"21" N:3994346.710 E:436967.531 (PK NAIL")
*SURVEY BASED ON MONUMENTS:
4.
5.
BE FUNCTIONALIZED PROPERLY.
STORM DRAINAGE SYSTEM SUCH AS STORM LINE, CONCRETRE DITCH, AND HEADWALL SHALL3.
S L O
P E
11-
10-
10-
7.
939.61
939.936
939.886
939.546
940.186
939.926
939.746
939.706
939.676
940.446
939.936
940.236
940.196
939.546
939.596
939.556
939.566
939.396
939.246
939.396
939.076
939.246
939.086
939.036
938.816
938.976
938.946
938.916
938.826
937.456
937.396
937.546
938.136
939.016
939.016
938.906
937.806
936.986
SEE DETAIL
CONCRETE RETAINING WALLS
REPLACE EXISTING RETAINING WALLS WITH NEW
RETAINING WALLS.
REPLACE EXISTING RETAINING WALLS WITH NEW CONCRETE
PROVIDE CONCRETE BOUNDARY MARKERS.
OMA SPEC.
EARTH WORKED AREA SHALL BE PROPERLY STRUCTUAL EARTH FILLED AND COMPACTED IAW
THE EXACT LOCATIONS, AND SHALL DEVELOP THE APPROPRIATE PLAN.
THE CONTRACTOR SHALL VERIFY THE SITE CONDITION AND DO THE CONFIRMATIONS FOR
N
12-
AND SIGN BOARDS.
GATES, (W=1,200, H=2,400) WITH NECESSARY ACCESSORIES
PROVIDE CHAINLINK FENCE, (TYPE FE-7, H=2,400) AND SINGLE
E 436942.365 N 3994471.028
STA. 146.279
STA. 0+000
FENCE CORNER #1
E 436919.573 N 3994495.230
STA. 113+035
FENCE CORNER #4
E 436956.342 N 3994519.474
STA. 68.992
FENCE CORNER #3
E 436972.409 N 3994490.322
STA. 35+706
FENCE CORNER #2
13 13
DRAWINGS, C-603 & C-607
FENCE PROFILE, "C-9" AND STANDARD DETAIL
SEE OVERALL SITE FENCING AND MARKER PLAN, ’C-4’,
NECESSARY ACCESSORIES AND SIGN BOARDS
AND SINGLE GATE, (W=1,200, H=2,400) WITH
PROVIDE CHAINLINK FENCE, (TYPE FE-7, H=2,400)
DETAIL
AND MARKER PLAN, "C-4", AND
SEE THE OVERALL SITE FENCING
PROVIDE CONCRETE BOUNDARY MARKERS
SEE TYP. SECTIONS & DETAIL
NEW STEEL GRATING COVERED CONCRETE DITCH
REPLACE EXISTING CONCRETE OPEN DITCH WITH
COORDINATES ARE BASED ON WGS84, UTM ZONE 52N, CORRDINATE SYSTEM.
KU, HUN MO
CHI, K. K.
27 DEC 22
REPLACE EXISTING HELIPAD, H-609
SALEM SITE
CIVIL
SITE LAYOUT PLAN
KU-10001-2J
AS SHOWN 3 13
D - 23 - 03
C-3
TEMPORARY FENCE SHALL BE INSTALLED DURING THE CONSTRUCTION PERIOD.
WITH THE GUIDANCE OF RELEVANT AGENICIES AND DPW.
SIGNS AND SIGN BOARDS SHALL BE INSTALLED ON THE NEW CHAIN-LINK FENCE IN ACCORDANCE
COVERED WITH SOLID SODDING AND TOPSOIL.
ALL UNPAVED, CUT/FILLED AREAS WITHIN THE PROJECT WORK LIMIT SHALL BE FULLY8.
9.
7.
6.
FENCES AND GATES SHALL BE INSTALLED WITHIN THE SITE BOUNDARY LINES.
THE CONTRACTOR SHALL VERIFY THE COORDINATES FOR THE SITE BOUNDARY. AND CHAINLINK
SEE DETAIL
PROVIDE CONCRETE HEADWALL
PROVIDE CONCRETE HEADWALL.
#1 (REPAIR/MAINTENANCE)
#2 (GENERAL REQUIREMENTS)
4.
10.
11.
P U
M P
F U
E L
9.00
1.00
0.40
H-60
S-2200 S-2102
S
0S-2207
AS SHOWN
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
GRAPHIC SCALE
0 2000010000
SCALE: 1 : 500
N
H-60
- SCALE : 1 / 5004
POINT NO. NORTH EAST
3994471.028 436942.365
436919.573
436956.3423994519.474
436972.4093994490.322
436944.0483994472.109
436957.3823994447.086
436951.5943994434.165
436951.5913994423.483
436950.9113994404.113
3994495.230
3994376.578 436956.976
3994370.385 436954.719
3994359.465 436956.522
3994303.189 436910.123
3994298.862 436915.027
3994294.421 436921.193
3994274.407 436934.974
3994264.827 436940.021
F-2
F-1
F-3
F-4
F-5
F-6
F-7
F-8
F-9
F-10
F-11
F-12
F-13
F-14
F-15
F-16
F-17
OVERALL SITE FENCING AND MARKER PLAN
POINT NO. NORTH EAST
3994258.003
436960.678
436954.0573994256.768
436947.0943994259.592
436906.4513994310.636
436905.3953994316.366
436905.5583994321.363
436907.9873994327.012
436910.8753994333.898
3994256.597
3994345.994 436913.471
3994359.336 436916.837
3994367.494 436923.501
3994371.464 436931.603
3994376.569 436937.303
436940.566
3994403.317 436949.044
3994423.483 436949.591
3994434.165 436949.594
3994447.086 436955.382
3994361.270 436957.704
3994343.954 437005.564
3994350.041 437011.702
3994361.195 437013.088
M-1
M-2
M-3
M-4
M-5
M-6
M-7
M-8
M-9
M-10
M-11
M-12
M-13
M-14
M-15
M-16
M-17
M-18
M-19
M-20
M-21
M-22
M-23
3994380.380
436975.514 PROJECT WORK LIMITS
M-15
M-14
M-13
M-11
M-9
M-7
M-5
M-8
M-6
M-10
M-12
F-13
F-14
F-15 F-16
F-17
M-4
M-3
M-2
M-1
M-16
M-17
M-18
M-19
M-20
M-21
M-22
M-23
F-12 F-11
F-10
F-9
F-8
F-7
F-6F-5
F-4
F-3
F-2
F-1
CHAIN-LINK FENCE
CONNECT TO EXISTING
CHAIN-LINK FENCE
CONNECT TO EXISTING
NEW SINGLE GATE
NEW SINGLE GATE
(WITHIN PROJECT WORK LIMITS)
SEE THE COORDINATES "A"
PROVIDE CONCRETE MARKERS
A (SITE MAIN BOUNDARY)
COORDINATES FOR MARKERS- COORDINATES FOR CHAIN-LINK FENCE
B
SITE BOUNDARY LINE
STANDARD DETAIL DRAWINGS, C-603 & C-607
SEE THE COORDINATES "B" AND
NECESSARY ACCESSORIES AND SIGN BOARDS
AND SINGLE GATES, (W=1,200, H=2,400) WITH
PROVIDE CHAINLINK FENCE, (TYPE FE-7, H=2,400)
STANDARD DETAIL DRAWINGS, C-603 & C-607
SEE THE COORDINATES "B" AND
NECESSARY ACCESSORIES AND SIGN BOARDS
AND SINGLE GATES, (W=1,200, H=2,400) WITH
PROVIDE CHAINLINK FENCE, (TYPE FE-7, H=2,400)
NEW SINGLE GATE
C-44 13
D - 23 - 03KU-10001-2J
OVERALL SITE FENCING AND MARKER PLAN
REPLACE EXISTING HELIPAD, H-609
SALEM SITE
CIVIL
27 DEC 22
CHI, K. K.
KU, HUN MO
SCALE : 1 / 100
CIVIL
AS SHOWN
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
C-5
GRAPHIC SCALE
SCALE: 1 : 100
2000 40005
D - 23 - 03KU-10001-2J
HELIPAD PLAN
A
(15 CM) WIDE BLACK BORDER.
GROUNDING POINT, 18 INCH (45.72 CM) DIAMETER MARKING SHALL BE PROVIDED W/ 6 INCH
NOTES:
1.
2.
3.
4.
HELIPAD PAVEMENT MARKING PLAN
SCALE : 1 / 100
STATIC
S1
CONNECTION
GROUND
C
GROUND POINT MARKING
GROUNDING POINT
GROUNDING POINT
CENTERED ON
YELLOW PAINT
RETRO REFLECTIVE
460 DIAMETERPAINT BORDER
150 WIDE BLACK
B
NOT TO SCALE
MOORING POINTS AND STATIC GROUNDS
,0
,0
,8
,0
,2
,0
,2
,8
,0
1,300
,1
12,000
3,400
STATIC GROUND
34,000
6,000 2,200 7,000
N
PLAN AND DETAILS
HELIPAD PAVEMENT MARKING
5 13
KU, HUN MO
CHI, K. K.
27 DEC 22
NOT TO SCALE
1, 1, ,1
4,8004,8002,2007,000
MOORING POINTS
REPLACE EXISTING HELIPAD, H-609
(1 EA, TYP.)
STATIC GROUND POINT
(6 EA, TYP.)
MOORING POINTS
6,100
,1
CONTRACTION JOINT
6,100
(INLINE)
WHITE COLOR
SALEM SITE
MARKING OF HELIPAD SHALL BE WHITE RETROREFLECTIVE PAINT WITH 150MM BLACK OUTLINE.
(OUTLINE)
150MM BLACK COLOR
(SEE GROUND POINT MARKING DETAIL).
ALPHA-NUMERIC IDENTIFICATION MARKING. GROUND POINT WILL BE MARKED "S-1"
GROUND POINT MUST BE MARKED "STATIC GROUND CONNECTION" IN BLACK AND CONTAIN
YELLOW CIRCLE.
GROUNDING POINT SHALL BE ENCIRCLED W/ 18 INCH (45.72 CM) DIAMETER RETRO REFLECTIVE
AS SHOWN
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
C-6
GRAPHIC SCALE
SCALE: 1 : 100
2000 40006
D - 23 - 03
LEGEND:
CONTRACTION JOINT WITH DOWEL BARS
CONTRACTION JOINT WITH TIE BARS
EXPANSION JOINT
A P P
R O
X ,0
C O
N T R
A C
T
IO
N
J O
IN
T (8
,7
JOINT
EXPANSION
JOINT
EXPANSION
CONCRETE RETAINING WALL
JOINT
LONGITUDINAL CONTRACTION
JOINT
TRANSVERSE CONTRACTION
APPROX. 34,000
CONTRACTION JOINT, (8 @ 4,250)
J O
IN
T E
X P
A N
S
IO
N
J O
IN
T E
X P
A N
S
IO
N
CONCRETE DITCH
STEEL GRATING COVERED
PCC PAVEMENT LAYOUT PLAN
PCC PAVEMENT
KU, HUN MO
CHI, K. K.
27 DEC 22
KU-10001-2J
PCC PAVEMENT LAYOUT PLAN
6 13
JOINT
EXPANSION
N
REPLACE EXISTING HELIPAD, H-609
SALEM SITE
fy = 440 Mpa fy = 392 Mpa (GRADE 60) f’c = 24 MPa fu = 482 Mpa
1. CONCRETE : (MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS)
ALL CONCRETE UNLESS NOTED OTHERWISE
HOT-ROLLED DEFORMED BAR
2. STEEL
WELDED WIRE FABRIC
MATERIAL STRENGTHS
3. WELDING ELECTRODE:
CONCRETE
CONFORM TO ACI STANDARDS (ACI 318, ACI 301.)
1. ALL WORK FOR CONCRETE AND REINFORCING STEEL SHALL
19mm UNLESS OTHERWISE NOTED.
2. CHAMFER ALL EXPOSED EDGES OF CAST-IN-PLACE CONCRETE
300MM.
3. REINFORCING BAR LAP SPLICES SHALL NOT BE LESS THAN
LEAN CONCRETE f’c = 14 MPa
AS SHOWN
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
C-7
GRAPHIC SCALE
SCALE: 1 : 100
2000 4000
D - 23 - 03
ABBREVIATIONS
E.P.J.: EXPANSION JOINT
C.T.J.: CONTRACTION JOINT
A P P
R O
X ,3
E.P.J
,6
,5
,5
,6
8,650 8,500 8,500 8,650
,6
C.T.J
APPROX. 34,300
,5
,5
C .T .J
C .T .J
E .P .J
E.P.J
C.T.J
,6
RETAINING WALL PLAN
E .P .J
E .P .J
KU, HUN MO
CHI, K. K.
KU-10001-2J
7 13
27 DEC 22
RETAINING WALL PLAN
8,800E .P .J
E .P .J
’WALL’ TOP EL.=939.845
’WALL’ TOP EL.=939.770
’WALL’ TOP EL.=939.695
’WALL’ TOP EL.=939.620
’WALL’ TOP EL.=939.545 ’WALL’ TOP EL.=939.545
’WALL’ TOP EL.=939.620
’WALL’ TOP EL.=939.695
’WALL’ TOP EL.=939.770
’WALL’ TOP EL.=939.845
’W A L L T
O P
E L
.8
’W A L L T
O P
E L
.8
’W A L L T
O P
E L
.8
C.T.J C.T.J
N
REPLACE EXISTING HELIPAD, H-609
’W A L L T
O P
E L
.5
’W A L L T
O P
E L
.5
8,800
SALEM SITE
~HELIPAD~
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
CIVIL
AS SHOWN
KU, HUN MO
CHI, K. K.
KU-10001-2J
REPLACE EXISTING HELIPAD, H-609
C-8
8 13
TYPICAL SECTIONS
- 8 SCALE : 1 / 75
APPROX. 30,600 1,000
MIN.MIN.
1,000 1,100
(ASSUMED)
EXISTING FINISH GRADE
(ASSUMED)
EL=939.695
CONCRETE RETAINING WALL
PCC PAVEMENT, (T=200)
BASE COURSE, (T=300)
CHAIN-LINK FENCE
SL
OPE
SL
OPE
CHAIN-LINK FENCE
CONCRETE RETAINING WALL
8 SCALE : 1 / 75
APPROX. 34,6001,000
MIN. MIN.
1,000
(ASSUMED)
EL=939.845
(ASSUMED)
EL=939.545
1% SLOPE
(MIN.)
(ASSUMED)
EXISTING FINISH GRADE
BASE COURSE, (T=300)
PCC PAVEMENT, (T=200)
CONCRETE RETAINING WALL
CHAIN-LINK FENCE
CHAIN-LINK FENCE
CONCRETE DITCH
SLOPE
SLOPE
VARIES VARIESSEE THE SITE PLAN SEE THE SITE PLAN
VARIESSEE THE SITE PLAN
TYPICAL SECTION-1
TYPICAL SECTION-2
GRAPHIC SCALE
SCALE: 1 : 75
30001500750
SALEM SITE
27 DEC 22
D - 23 - 03
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
C-9
D - 23 - 03
KU, HUN MO
CHI, K. K.
KU-10001-2J
9 13
27 DEC 22
REPLACE EXISTING HELIPAD, H-609
CHAINLINK FENCE PROFILE
CHAINLINK FENCE PROFILE
S T
A
S T
A
S T
A
S T
A
S T
A
S T
A
STATION
E L E
V A T
IO
N
E T E
R
STATION
S T
A .5
S T
A
S T
A
1.
S T
A
.7
S T
A
.2
E L E
V A T
IO
N
E T E
R
HORIZ 1 : 100, VERT 1:75
SCALE
GRAPHIC SCALE
SCALE: 1 : 100
2000 4000
GRAPHIC SCALE
SCALE: 1 : 75
1500 3000
TOP OF HELIPAD
TOP OF HELIPAD
CHAINLINK FENCE
CHAINLINK FENCE
SINGLE GATE
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
REVIEWED BY
SHEET OFAS SHOWN
FES
KU-10001-2J
CHI, K. K.
27 DEC 22
C-10
D - 23 - 03
*EXTRA STRENGTH PIPE WILL BE FILLED OR PLUGGED WHEN USED
INCHES
THICKNESS
PAVEMENT
INCHES
LENGTH
DOWEL
MINIMUM
INCHES
SPACING
DOWEL
MAXIMUM
DOWEL DIAMETER AND TYPE
LESS THAN 8
8 TO 11
12 TO 15
3/4-INCH BAR
*EXTRA STRENGTH PIPE WILL BE FILLED OR PLUGGED WHEN USED
1-INCH BAR
AND EXPANSION JOINTS
CONSTRUCTION,CONTRACTION,
DOWEL SIZE AND SPACING FOR
THIS PROJECT
~ EXST SUB-GRADE (FULLY COMPACTED) ~
PCC PAVEMENT (T=200)
BASE COURSE (T=300)JOINT SEALANT
PAVEMENT THICKNESS, INCHES SPACING OF JOINT,FEET
LESS THAN 9
9 TO 12
OVER 12
15 TO 20
TRANSVERSE CONTRACTION JOINTS
MAXIMUM ALLOWABLE SPACING OF
12 1/2TO 15
20 TO 25
THIS PROJECT
KU, HUN MO
DOWEL
ONE END OF
PAINT AND OIL
THROUGH JOINT
REINFORCING STEEL IS NOT CARRIED
SEE JOINT SEALANT
DOWEL TO BE USED
THREADED SPLIT TYPE
EITHER ONE PIECE OR
D" DENOTES DOWEL DIAMETER
H d /2
D
A
DOWELED TRANSVERSE OR LONGITUDINAL
SEE JOINT SEALANT
B
TIED TRANSVERSE OR LONGITUDINAL
H d /2
NOT TO SCALE
- 10
CONTRACTION JOINTS FOR
REINFORCED CONCRETE PAVEMENTS FOR AIR FORCE PAVEMENT IS 20 FEET.
*THE MAXIMUM SPACING OF TRANSVERSE CONTRACTION JOINTS
THIS PROJECT
SURFACE
PAVEMENT
SEALER
JOINT
POURED
SEALER
JOINT
POURED
SEALER
JOINT
POURED
BOTTOM
JOINT
SURFACE
PAVEMENT
INSERT
OR
SAWCUT(1/8")
INITIAL
CRACK
JOINT
BUTTED
MATERIAL
BACKER
MATERIAL
BACKER
MATERIAL
BACKER
FILLER
JOINT
SURFACE
PAVEMENT
SEALER
JOINT
POURED
SEALER
JOINT
POURED
SEALER
JOINT
POURED
BOTTOM
JOINT
SURFACE
PAVEMENT
INSERT
OR
SAWCUT(1/8")
INITIAL
JOINT
BUTTED
TAPE
SEPARATING
CRACK
SURFACE
PAVEMENT
TAPE
SEPARATING
SURFACE
PAVEMENT
T D
W
D
W W
D
" MIN4
W W W
DDD
T
" MIN4
CONTRACTION JOINT CONSTRUCTION JOINT EXPANSION JOINT
NOT TO SCALE
PCC PAVEMENT (TYP)
NOT TO SCALE
JOINT SEALANT DETAILS
FT
JOINT SPACING
MIN MAX
WIDTH,IN
<25
25-50
>50 1.0 8 11-
THIS PROJECT
OF PAVEMENT
TOP OF SEALANT WILL BE 1/8 IN TO 1/4 IN BELOW TOP
NOTE:
10-
EXTRA STRENGTH PIPE
1 - 1/4 INCH BAR, OR 1 INCH
10 13
* Hd: 200MM
H d
H d
SEE JOINT SEALANT
NEW HELIPAD PAVEMENTSLIP FIT
EXPANSION CAP
DOWEL
ONE END OF
PAINT AND OIL
B HELIPAD PAVEMENT AND RETAINING WALL
THICKENED-EDGE JOINT/ BETWEEN NEW
A
PCC PAVEMENT SECTION (TYP.)
RETAINING WALL
NEW CONCRETE
EXPANSION JOINT
DOWEL BAR 2
2,000
3"2"1"
H d
D
c. 1/6 SLAB THICKNESS FOR PAVEMENTS MORE THAN 18 INCHES
b. 3 INCHES FOR PAVEMENTS 12-18 INCHES*
a. 1/4 SLAB THICKNESS FOR PAVEMENTS LESS THAN 12 INCHES
(CONTRACTION JOINT)
T=DEPTH OF INITIAL SAWCUT OR INSERT TYPE JOINT FORMER
D=DEPTH OF SEALANT(1.0 TO 1.5 x W)
W=WIDTH OF SEALANT RESERVOIR(SEE TABLE)
PCC PAVEMENT DETAILS
REPLACE EXISTING HELIPAD, H-609
SALEM SITE
AND SPACED 2’-6" ON CENTERS
NO. 5 (D16) DEFORMED STEEL TIE BARS 2’-5" LONG
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
REVIEWED BY
SHEET OFAS SHOWN
FES
- NOT TO SCALE11
C-11
D - 23 - 03
NOTES:
CONCRETE SURFACE SHALL BE FINISHED WITH PATTERN.2.
1.
C
EXPANSION JOINT (EJ)
D
CONTRACTION JOINT (CJ)
TYPICAL RETAINING WALL DETAILS
B
STEP FOOTING DETAIL
D
V A
R
IE
S D
D1
A
SECTION (TYP.)
EXPANSION JOINT
PCC PAVEMENT, (HELIPAD)
BACKFILL
COMPACTED SATISFACTORY
PER SPECIFICATIONS
IN THE WEEP HOLE AREAS
DRAIN CORE PERFORATED
STRUCTURE/ATMOSPHERE
TO NEAREST DRAINAGE
FABRIC TO DISCHARGE
COMPOSITE FILTER
PIPE WRAPPED IN
150 0 PERFORATED
FABRIC
FILTER
MATERIAL
DRAIN
GRAVEL
b1 b3 b2 b5 b6 b7 b8
STRUCTURAL BACKFILL
OFFSET BY 750
ADJACENT ROWS
@ 1500 OC
050 WEEP HOLES
b4
50 CL
50 CL
X
X
H 1, H w
C
W2 B
5 15
M
IN
C
L
C
L
D
M
IN
JOINT FILLER
ELASTOMERIC
PREFORMED
GREASE W/ EXP CAP
@ 400 OC, ONE SIDE
D16x750 LG DOWELS
SEALANT 19 CHAMFER
M
IN
C
L
C
L
19 CHAMFER
AT CJ
HORIZONTAL BARS
STOP ALT
~HELIPAD SIDE~
~HELIPAD SIDE~
~HELIPAD SIDE~
M
IN
MIN.
19 CHAMFER
DOWEL
ONE END OF
PAINT AND OIL
JOINT FILLER
ELASTOMERIC
PREFORMED
GREASE W/ EXP CAP
@ 400 OC, ONE SIDE
D16x750 LG DOWELS b3 b1 b2 b8
X
X
RETAINING WALL REINFORCING BARS AND SPACING(mm)
MARK
WALL
H, (M)
HEIGHT STEM FOOTING
RW1
RW2
RW3 LESS THAN 3.50
5.00 ~ 6.50
3.50 ~ 5.00
2,100
2,800
3,500
D16@150
D22@150
D22@100
D16@200
D16@200
D16@200 D22@200
D22@300
D16@300 D13@200
D13@200
D13@200
D16@200
D16@200
D16@200 D16@200
D16@200
D16@200 D16@150
D22@100
D22@150
D22@100
D16@150
D22@150
MARK
WALL
H, (M)
HEIGHT
RW3
RW2
RW1
LESS THAN 3.50
3.50 ~ 5.00
5.00 ~ 6.50
BASE FOOTING (mm) STEM WALL (mm)
X1 X2 b1 b2 b3 b4 b5 b6 b7 b8 B C D1 W1 W2
2,700
3,800
4,700 5,600
4,500
3,400 700
300 900
E
CORNER EXPANSION JOINT (EJ)
F
STEM BAR PATTERNS
3.
PROVIDE THE DESIGN, AND DESIGN ANALYSIS FOR THE RETAINING WALLS.4.
RETAINING WALL SIZES
TYPICAL RETAINING WALL DETAILS
KU, HUN MO
CHI, K. K.
KU-10001-2J
27 DEC 22
1,000
MIN.
DESIGN AND DRAWINGS TO MEET THE CURRENT EXISTING CONDITION FOR THE WALL.
THE CONTRACTOR SHALL VERIFY THE SITE CONDITION AND SUBMIT COMPLETED
REPLACE EXISTING HELIPAD, H-609
SALEM SITE
RETAINING WALL EXPOSED EDGES SHALL BE CHAMFERED A MINIMUM OF 19 mm.
11 13
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
REVIEWED BY
SHEET OFAS SHOWN
FES
- NOT TO SCALE
BEARING BAR
B
TWISTED
10 SQ CROSS BAR
CROSS BAR
PITCH OF
GRATING WIDTH
100GRATIN
G L
ENGTH
TYP.
H
BEARING B
AR
P
ITCH O
F
450 & SMALLER
500 TO 600
650 TO 750
75 6
H B C
ANGLE BAR
L70x70x6
L80x80x6
STEEL GRATING SCHEDULE
TRENCH WIDTH
WHEEL LOAD = 79 KN(8.0 TONS).
FOR 20-TON DESIGN TRUCK LOAD:
STEEL GRATINGS ON CONCRETE DITCHES SHALL BE
COMPLY WITH SPECS. MINIMUM TRAFFIC LOAD FOR
STEEL GRATINGS FOR CONCRETE DITCHES SHALL
NOTE:
25675 L80x80x6
BEARING B
AR
H
C
E
STEEL GRATINGS
C-12
D - 23 - 03
BEARING BARS
GRATING FRAME
@ 15.00 M O.C.
EXPANSION JT.
ANGLE BAR
CROSS BAR
(SEE NOTE)
STEEL GRATINGS
S L P
S L P
A
PLAN
D
E
B
LONGITUDINAL RBARS
SEAT AND D13
DISCONTINUE GRATING
REBAR
AS LONGITUDINAL
OILED SPACED SAME
ONE END PAINTED AND
DOWEL 400 LONG.
19mm DIA. PLAIN BAR
@ 15M MAX.
(EXP. JOINT)
MATERIAL
JOINT FILLER
PREMOLDED
13 THK.
V A
R
IE
S D
SECTION
D
F
FINISH GRADE
(SEE TABLE)
ANGLE BAR
@ 600 MAX.
WELDED TO ANGLE
D13 ANCHOR BAR
@ 200 O.C.
D13 BAR
GRATE FRAME
FLAT BAR
GRATING FRAME
WELDED TO
BEARING BARS
GRATING FRAME
WELDED TO
CROSS BARS
C
DETAIL
24 MPa CONC.
F2
SECTION
AFTER FABRICATION.
GRATING AND GRATE FASTENER SHALL BE HOT DIPPED GALVANIZED
GRATE SECTIONS TO BE BOLTED DOWN AT ALL 4 CORNERS.
NOTES:
1.
2.
BOLT W/ NUT
SADDLE PLATE
F3
DETAIL
TRENCH WIDTH300
VARIE
S
D
WIDTHGRATING
D D
SEE NOTE
STEEL GRATING
O.C. E.W.
D13 @ 200
CEMENT FILLER
SEE DETAIL
SLP.SLP.
C
SECTION
B
(M
IN
COMPACTED NFSM
(24 MPa)
CONC. WALL
200 500 200150
BOLT W/ NUT
6mm 0 HOLD DOWN
GRATING FASTENER
3mm SADDLE PLATE BAR
SEATING ANGLE BAR
GRATE FASTENER
SEE DETAIL
F3
ANGLE BAR
OUTLINE OF
BEARING BAR
ANGLE BAR
OUTLINE OF
ISOMETRIC
F1
A
PLAN
WING WALL
1,000 MIN.
CONCRETE WING WALL
PVC PIPE (D=300)
M
IN
B
SCOUR APRON
STONE MASONRY
1,200
MIN.
- NOT TO SCALE12
CONCRETE DITCH W/ STEEL GRATINGS
CONCRETE HEADWALL W/WING WALL DETAIL
SECTION
B
WING WALL
1,000 MIN. 150 FINISH GRADE
MATERIAL (NFSM)
NON- FROST SUSCEPTIBLE
D13 @ 200 OC, EW
PVC PIPE (D=300)
D13 @ 200 OC, EW
1501,200
MIN.
SCOUR APRON
STONE MASONRY
HORIZ BAR
D13@ 200 OC
VERT BARS
D13 @ 200 OC
V A
R
IE
S
SLOPE
BEHIND & UNDERNEATH WINGWALLS.
PROVIDE 1000 THICK NON- FROST SUSCEPTIBLE MATERIAL (NFSM)
NOTE:
1.
KU, HUN MO
CHI, K. K.
27 DEC 22
12 13
KU-10001-2J
REPLACE EXISTING HELIPAD, H-609
1,
- NOT TO SCALE12
3 CONCRETE BOUNDARY MARKER
FINISH GRADE
(SQ.)
CONCRETE MARKER
DETAILS
SALEM SITE
D19- REINFORCING BAR
A
PLAN
SECTION
B
EXPOSED EDGES SHALL BE CHAMFERED.
NOTE:
1.
NAIL (STAINLESS STEEL)
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
SHEET OF
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORKS
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
C-13
D - 23 - 03
A
MOORING POINT DEVICE PLAN
NOT TO SCALE
B
NOT TO SCALE
MOORING POINT DEVICE SECTION
MAX.
HELIPAD PAVEMENT
A
NOT TO SCALE
STATIC GROUND PLAN
STATIC GROUND DETAILS
NOT TO SCALE
B
NOT TO SCALE
SECTION
A P P
R O
X
HELIPAD PAVEMENT
R=
R=19
ROUNDED EDGE
HOOK STYLE ROD ENDS
SLEEVE FOR SHEPHERDS
COPPER COMPRESSION
COPPER CLAD STEEL
19mm( 3/4") x 3,000mm
C
NOT TO SCALE
SECTION
B
C
B
22 O
CORED HOLES
2-13 O
.5
NOTE:
MOORING DEVICE TO BE CAST IN DUCTILE IRON OR EQUAL.1.
HELIPAD PAVEMENT
DEVICE
MOORING POINT
1,200 LONG
20 O BARS
1,000 LONG
20 O BARS
C
NOT TO SCALE
SLAB REINFORCEMENT
NOTES:
1.
DEVICE AND 75mm BELOW PAVEMENT SURFACE.
THESE 20 O REINFORCING BARS SHALL BE PLACED 75mm FROM MOORING
JOINTS TO PROVIDE COVER.
THE ENDS OF REINFORCING BARS SHALL BE PLACED MIN. 75mm FROM PAVING2.
PAVEMENT
TOP OF HELIPAD
NOTES:
1.
2.
THE CONTRACTOR SHALL PERFORM MOORING TEST.
REACTION (HEAVY VEHICLE, ETC.) THAT IS CAPABLE OF APPLYING A TENSILE LOAD OF 71,172 N [16,000 LB].
THE MOORING TESTS SHOULD BE ACCOMPLISHED USING A HYDRAULIC RAM OR SIMILAR DEVICE AND AN APPROPRIATE
OF 19.15 33/64 FROM THE PAVEMENT SURFACE (SEE ABOVE FIGURE)* CAN BE MAINTAINED DURING LOAD TESTING.
THE LENGTH OF MOORING CHAIN AND CONNECTING SHACKLE SHOULD BE SELECTED IN SUCH A WAY THAT AN ANGLE
APPROPRIATE SAFETY PRECAUTIONS SHOULD BE TAKEN AT ALL TIMES DURING LOAD TESTING OPERATIONS.
4,448 N [1,000 LB] INCREMENTS UP TO 71,172 N [16,000 LB] WITH EACH LOAD INCREMENT HELD FOR AT LEAST 60 SECONDS.
THE MOORING POINTS SHOULD BE LOADED IN 1,130 kg [2,500 LB] INCREMENTS UP TO 44,482 N [10,000 LB] AND IN
TO PASS TEST REQUIREMENTS, MOORING POINTS SHALL NOT DEFORM PERMANENTLY UNDER 71,172 N [16,000 LB] LOAD.
MOORING AND GROUNDING POINTS OHMS TEST RESULTS & TEST DATES SHALL BE PROVIDED TO USER.
UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN MILLIMETER.
3.
4.
5.
6.
7.
8.
9.
13- NOT TO SCALE
MOORING POINT DEVICE DETAILS2
STATIC GROUND DETAILS
MOORING POINT DEVICE ANDPOINTS WILL NOT EXCEED 10,000 OHMS UNDER NORMAL DRY CONDITIONS.
GROUNDING SHALL BE IN ACCORDANCE WITH IEEE STANDARD 81,THE MAXIMUM RESISTANCE MEASURED OF GROUNDING
KU, HUN MO
CHI, K. K.
KU-10001-2J
27 DEC 22
13 13
REPLACE EXISTING HELIPAD, H-609
| KU-10001-2J_T01-Default-000 |
| KU-10001-2J_C01-Default-000 |
| KU-10001-2J_C02-Default-000 |
| KU-10001-2J_C03-Default-000 |
| KU-10001-2J_C04-Default-000 |
| KU-10001-2J_C05-Default-000 |
| KU-10001-2J_C06-Default-000 |
| KU-10001-2J_C07-Default-000 |
| KU-10001-2J_C08-Default-000 |
| KU-10001-2J_C09-Default-000 |
| KU-10001-2J_C10-Default-000 |
| KU-10001-2J_C11-Default-000 |
| KU-10001-2J_C12-Default-000 |
| KU-10001-2J_C13-Default-000 |
File details come from the government source that posted it. Updated .