KJD- 25.01 SHEET SET 2.10.26 Flattened.pdf
PDF 10 MB Posted
- Attached to
- Downtown Revitalization Project
- Solicitation number
- 1037TOC-26-001
- Issued by
- Moore County, Cleveland Town, North Carolina
About this file
This is a construction project sheet set for the Town of Carthage, North Carolina's Downtown Revitalization project, prepared by LKC Engineering, PLLC. The project encompasses improvements to the traffic circle, adjoining roads, and surrounding hardscape and parking areas in downtown Carthage, with the primary scope including reconfiguration of the circle to improve vehicular movements and drainage, along with significant revisions to hardscape and landscaping to enhance pedestrian areas and overall downtown functionality and aesthetics. The sheet set includes comprehensive civil engineering plans covering general notes and legends, existing topographic survey, typical sections, roadway plans, drainage plans with 15-inch reinforced concrete pipe (RCP) installations at various slopes, traffic control plans, signing and marking plans, erosion control plans, and utility plans showing relocations of fire hydrants, gate valves, and storm drain infrastructure. Sealed bids are due at Carthage Town Hall by 2:00 pm local time on Friday, March 13, 2026, with construction to begin no later than May 18, 2026, and be completed by November 30, 2026. All bid-related questions must be submitted via email to Emily Yopp, Lindsay Whitson, or Trevor Hansen no later than February 28, 2026, with responses provided by March 2, 2026.
The project site is located in downtown Carthage at the intersection of Monroe Street (NC Highway 27), McReynolds Street, Martin Street, and Ray Street, adjacent to the Moore County Historic Courthouse. The existing topographic survey establishes elevations referenced to NAVD88 datum with a benchmark elevation of 583.21 feet. The drainage plan identifies multiple curb inlets, storm drain manholes, and drainage structures requiring relocation or installation, with specific rim elevations and invert elevations detailed throughout the project area. All utility line locations are based on utility records supplemented by field inspections; contractors are required to notify the North Carolina One Call Center at 1-800-632-4949 at least 48 hours prior to any excavation or construction activity and to coordinate electrical line relocation with Duke Progress Energy. The general contractor is responsible for field verification of all dimensions and elevations with the surveyor of record prior to construction commencement.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M
CREYNOLDS ST
MONROE ST
MAR
TIN
ST
CARTHAGE DOWNTOWN REVITALIZATION
CARTHAGE, NORTH CAROLINA
PROJECT VICINITY MAP
1" = 500'
140 Aqua Shed Court
Surveying License No. P-1095
Landscape Architecture Engineering
O: 910.420.1437 F: 910.637.0096
Aberdeen, NC 28315 lkcengineering.com
LKC Engineering, pllc
SHEET INDEX
PROJECT AREA
- COVER SHEET
C-1.0 GENERAL NOTES AND LEGEND
C-2.0 EXISTING TOPOGRAPHIC SURVEY
C-3.0 TYPICAL SECTIONS
C-4.0 ROADWAY PLAN
C-5.0 DRAINAGE PLAN
C-6.0 TRAFFIC CONTROL PLANS
C-6.1 TRAFFIC CONTROL PLANS
C-6.2 TRAFFIC CONTROL PLANS
C-6.3 TRAFFIC CONTROL PLANS
C-6.4 TRAFFIC CONTROL PLANS
C-6.5 TRAFFIC CONTROL PLANS
C-6.6 TRAFFIC CONTROL PLANS
C-6.7 TRAFFIC CONTROL PLANS
C-6.8 TRAFFIC CONTROL PLANS
C-6.9 TRAFFIC CONTROL PLANS
C-7.0 SIGNING AND MARKING PLANS
C-7.1 SIGNING AND MARKING PLANS
C-8.0 EROSION CONTROL PLANS
C-9.0 UTILITY PLANS
C-10.0 CROSS SECTIONS
C-10.1 CROSS SECTIONS
C-10.2 CROSS SECTIONS
D-01 DRAINAGE DETAILS
D-02 UTILITY DETAILS
V3 SOUTHEAST SHEETS
L-1.0 OVERALL KEY SHEET
L-2.0 EXISTING CONDITIONS AND DEMOLITION PLAN
L-3.0 SITE LAYOUT PLAN
L-3.1 SITE LAYOUT PLAN
L-3.2 SITE LAYOUT PLAN ENLARGEMENT
L-3.3 SITE LAYOUT PLAN ENLARGEMENT
L-3.4 SITE LAYOUT PLAN ENLARGEMENT
L-4.0 SITE MATERIALS PLAN
L-4.1 SITE MATERIALS PLAN
L-5.0 DETAILED SITE GRADING PLAN
L-5.1 DETAILED SITE GRADING PLAN
L-6.0 HARDSCAPE DETAILS
L-6.1 HARDSCAPE DETAILS
L-6.2 HARDSCAPE DETAILS
L-6.3 HARDSCAPE AND DRAINAGE DETAILS
L-6.4 SITE FURNISHINGS, SIGNAGE, AND LIGHTING DETAILS
L-7.0 SOIL AMENDMENTS PLAN
L-7.1 LANDSCAPE PLAN
L-7.2 LANDSCAPE PLAN
L-7.3 LANDSCAPE SCHEDULE & NOTES
L-7.4 LANDSCAPE DETAILS
L-7.5 CONCEPTUAL IRRIGATION PLAN
L-8.0 SITE FURNISHINGS AND HARDSCAPE LIGHTING PLAN
L-8.1 SITE FURNISHINGS AND HARDSCAPE LIGHTING PLAN
L-9.0 PHASING PLAN
L-9.1 INTERIM SIDEWALKS PLANS
G
2-4-46
OCTOBER, 2025
MFL
JDM
C-1.0
Fi le
: L
KJ
D
-2 5.
C ar th ag e
D ow nt ow n St re et sc ap es \8
D ra w in gs
\8
D es ig n
D ra w in gs \0
Ci vi l\
KJ
D
-2 5.
C
L
EG
EN
D .d w g, B y:
S al az ar
, P lo tt ed
Tu e Fe b
, 2 at
:2
5p m
GE
N
ER
AL
N O
TE
S
AN
D
L
EG
EN
D
ABBREVIATIONS
ABBREVIATION: DESCRIPTION: ABBREVIATION: DESCRIPTION:
A/C AIR CONDITIONING NIC NOT IN CONTRACT
ADJ ADJACENT NTS NOT TO SCALE
AL AREA LIGHT
APROX APPROXIMATE O.C. ON CENTER
ASSM ASSEMBLY OHE OVERHEAD ELECTRIC
ASPH ASPHALT
PC POINT OF CURVATURE
BLDG BUILDING PI POINT OF INTERSECTION
B.O. BLOW-OFF PIV POST INDICATION VALVE
BOC BACK OF CURB PP POWER POLE
BOW BOTTOM OF WALL PT POINT OF TANGENCY
BX BOX PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
C.F. CUBIC FOOT
CI CURB INLET R RADIUS
CL CENTER LINE R.J. RESTRAINED JOINT
CONC CONCRETE R/W, ROW RIGHT OF WAY
CONST CONSTRUCTION RCP REINFORCED CONCRETE PIPE
CY CUBIC YARD RDCO ROOF DRAIN CLEAN OUT
REQD REQUIRED
DEMO DEMOLISH (DEMOLITION) RQMT REQUIREMENT
DP DEEP RT RIGHT
DI DUCTILE IRON RWM RIGHT OF WAY MONUMENT
D.I.P. DUCTILE IRON PIPE
DIA DIAMETER SCH SCHEDULE
DIM DIMENSION SD STORM DRAIN
DWG DRAWING SDCO STORM DRAIN CLEAN OUT
SDMH STORM DRAIN MANHOLE
ECM EXISTING CONCRETE MONUMENT SED SEDIMENT
EIP EXISTING IRON PIPE SF SQUARE FOOT
EIS EXISTING IRON STAKE SPEC SPECIFICATION
ELEC ELECTRIC SQ SQUARE
ELEV ELEVATION SS SANITARY SEWER
ELMH ELECTRICAL MANHOLE SSCO SANITARY SEWER CLEAN OUT
ENCL ENCLOSURE SSMH SANITARY SEWER MANHOLE
EOC EDGE OF CONCRETE STA STATION
EOP EDGE OF PAVEMENT SY SQUARE YARD
EQPT EQUIPMENT
ESMT EASEMENT TBM TEMPORARY BENCHMARK
EX EXISTING TEL TELEPHONE
TEMP TEMPORARY
FES FLARED END SECTION THK THICK
FFE FINISH FLOOR ELEVATION TOC, T/C TOP OF CURB
FH FIRE HYDRANT TOW TOP OF WALL
FNC FENCE TPED TELEPHONE PEDESTAL
FO FIBER OPTIC TS&V TAPPING SADDLE & VALVE
FOC FACE OF CURB TYP TYPICAL
FT FOOT
UGE UNDERGROUND ELECTRIC
G.V. GATE VALVE UTIL UTILITY
GALV GALVANIZE
GND GROUND
GRAV GRAVEL
HDPE HIGH DENSITY POLYETHYLENE
L LENGTH
LF LINEAR FOOT
LFT LEFT
MAX MAXIMUM
MIN MINIMUM
MISC MISCELLANEOUS
M.J. MECHANICAL JOINT
GENERAL NOTES
ALL GENERAL NOTES, ABBREVIATIONS, SYMBOLS, AND OTHER INFORMATION INDICATED ON THIS SHEET SHALL APPLIED TO ALL
CONTRACT DOCUMENTS AND SHEETS IN THIS SET.
LEGEND / KEY
NAME: EXISTING NEW
ASPHALT PAVEMENT
CABLE TV
CENTERLINE
CURB & GUTTER
CONCRETE
CONTOUR MAJOR
CONTOUR MINOR
EASEMENT
FENCE
FIBER OPTIC
FORCE MAIN
GAS LINE
GAS VALVE
LIMITS OF DIST/CONST
LIGHT POLE
OVERHEAD ELECTRIC
POWER POLE
PROPERTY LINE
PROPERTY LINE - ADJ
RAILROAD
RIGHT-OF-WAY (ROW)
SANITARY SEWER LINE
SANITARY SEWER MH
SANITARY SEWER CO
SPOT EL. GS
SPOT EL. TOC
SPOT EL. TOW
STORM DRAIN FES
STORM DRAIN LINE
STORM DRAIN MH
STORM DRAIN CI
STORM DRAIN GI
STORM DRAIN YI
TELEPHONE LINE
TELEPHONE PEDESTAL
UNDERGROUND ELEC.
UTILITY POLE
WATER LINE
WATER VALVE
FIRE HYDRANT
WATER METER
WATER LINE BACKFLOW
WATER LINE REDUCER
EROSION CONTROL: NEW
TEMP. CONST ENT.
TEMP. SILT FENCE
TEMP. DIVERSION
TEMP. INLET PROTECT.
TEMP. ROCK PIPE INLET
PROTECTION
RIPRAP DISSIPATOR
TEMP. SILT FENCE
OUTLET
TEMP. SKIMMER BASIN
WITH BAFFLES
FAIRCLOTH SKIMMER
TEMP. SEDIMENT TRAP
WITH BAFFLES
TEMP. SLOPE DRAIN
TREE PROTECTION
ROLLED EROSION
CONTROL MATTING
1. THE GENERAL CONTRACTOR SHALL FIELD VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AT THE JOB SITE.
2. ALL ELEVATIONS SHOWN ARE IN REFERENCE TO THE BENCHMARK AND MUST BE VERIFIED BY THE GENERAL CONTRACTOR WITH
THE SURVEYOR OF RECORD PRIOR TO BEGINNING CONSTRUCTION. BENCHMARK IS AN ECM LOCATED ALONG THE PROPERTY
LINE OF THE SITE ______ AND HAVING AN ELEVATION OF ________.
3. HORIZONTAL COORDINATES BASED ON NC GRID NAD83 AND ELEVATIONS BASED ON NAVD88 DATUM.
4. ALL DIMENSIONS AND ALL ELEVATIONS ARE MEASURED TO BACK OF CURB UNLESS OTHERWISE NOTED.
5. THE INTENT OF THE LIMITS OF DISTURBANCE/CONSTRUCTION (LOD/C) SHOWN ON THE DRAWINGS IS TO DEFINE THE GENERAL
PROJECT AREA TO CONSTRUCT, INSTALL AND/OR MODIFY THE SITE. TYPICALLY, THE LOD/C WILL FOLLOW RIGHT-OF-WAY OR PROPERTY LINES. THE CONTRACTOR SHALL CONTACT THE OWNER'S REPRESENTATIVE REGARDING ANY QUESTIONS AS TO THE EXACT LOCATION OF THE LOD/C PRIOR TO BID AND PRIOR TO BEGINNING CONSTRUCTION. ALL ITEMS SHOWN ON THESE PLANS THAT DO NOT SPECIFICALLY STATE 'NOT-IN-CONTRACT (NIC), SHALL BE INCLUDED IN THE BID COST, INCLUDING ITEMS THAT
MAY BE OUTSIDE THE PROJECT LIMITS.
6. LOCATIONS OF EXISTING UTILITY LINES HAVE BEEN TAKEN FROM UTILITY RECORDS SUPPLEMENTED BY FIELD INSPECTIONS AND SHOULD INDICATE IN GENERAL THE TYPE OF UNDERGROUND UTILITIES NOW IN SERVICE. LOCATIONS SHOWN ARE NOT GUARANTEED. DEVELOPERS AND/OR CONTRACTORS SHALL NOT ONLY MAKE SUBSURFACE INVESTIGATIONS BUT SHALL ALSO ALLOW FOR CONTINGENCIES WHICH MIGHT ARISE BY REASON OF ENCOUNTERING UNRECORDED LINES OR LINES BEING IN DIFFERENT LOCATIONS THAN INDICATED ON THESE PLANS. AT LEAST 48-HOURS PRIOR OR SOONER IF REQUIRED BY THE LOCAL MUNICIPALITY TO ANY CONSTRUCTION ACTIVITY, EXCAVATION, GRADING, OR DIGGING ON THE SITE, THE GENERAL CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES TO VERIFY AND/OR FIELD-LOCATE THEIR RESPECTIVE UTILITIES (THE NORTH CAROLINA ONE CALL CENTER - 1-800-632-4949). ALL DAMAGE INCURRED TO EXISTING UTILITY LINES DURING
CONSTRUCTION SHALL BE REPAIRED AT THE GENERAL CONTRACTORS EXPENSE.
7. SURVEY, BASE MAPPING, & TOPOGRAPHICAL DATA PROVIDED BY LKC ENGINEERING, PLLC, JEFFREY L. GREEN, PLS, 140 AQUA SHED
CT., ABERDEEN, NC 28315, TEL. 910-420-1437.
C ar th ag e, N o rt h C ar o li n a
C A
R T H
A G
E D
O W
N T O
W N
R
EV
IT
A
LI
Z A
T
IO
N
A q u a
Sh ed
C o u rt
Su rv ey in g Li ce n se
N o P-
La nd sc ap e Ar ch ite ct ur e En gi ne er in g O
.4
.1
F:
.6
.0
A b er d ee n N
C lk ce n g in ee ri n g .c o m
LK
C
E n g in ee ri n g p ll c
BYDATESYM. DESCRIPTION
REVISIONS
DATE:
DESIGNED:
DRAWN:
CHECKED:
NO.
EM
EM
ELC
9 5
1 58
9 5
2 571
CP
CP
CP
EM
COUNTY OF
MOORE
MONROE ST.
MCREYNOLDS ST.
M
AR
TI
N
S T.
EX. HYDRANT
(TO BE RELOCATED)
EX. HYDRANT
(TO BE RELOCATED)
EX. HYDRANT
(TO BE RELOCATED)
EX. VALVE
(TO BE RELOCATED)
EX. CURB INLET
(TO BE RELOCATED)
EX. CURB INLET
(TO BE RELOCATED)
EX. CURB INLET
(TO BE RELOCATED)
EX. CURB INLET
(TO BE RELOCATED)
EX. CURB INLET
(TO BE RELOCATED)
EX. CURB INLET
(TO BE RELOCATED)
TBM: 1.5"EIP FLUSH
N: 581013.43 E: 1875552.11
ELEV: 583.21
EX. STORM INLET
EX
IS
TI
N
G
TO
PO
GR
AP
H
IC
S
UR
VE
Y
OCTOBER, 2025
MFL
JDM
C-2.0
Fi le
: L
KJ
D
-2 5.
C ar th ag e
D ow nt ow n St re et sc ap es \8
D ra w in gs
\8
D es ig n
D ra w in gs \0
Ci vi l\
KJ
D
-2 5.
C
X
-T O
PO
.d w g, B y:
S al az ar
, P lo tt ed
Tu e Fe b
, 2 at
:2
6p m
NOTES:
1. ALL GENERAL NOTES, ABBREVIATIONS, SYMBOLS, AND OTHER INFORMATION
INDICATED ON SHEET C-01 SHALL APPLY TO THIS PLAN.
2. THE PURPOSE OF THE PLAN IS FOR INFORMATIONAL PURPOSES ONLY. THOUGH THIS
PLAN IS FROM AN ACTUAL FIELD SURVEY IT IS NOT AND SHOULD NOT BE CONSIDERED
A RECORDABLE DOCUMENT.
3. ALL ELEVATIONS SHOWN ARE IN REFERENCE TO THE BENCHMARK AND MUST BE
VERIFIED BY THE GENERAL CONTRACTOR WITH THE SURVEYOR OF RECORD PRIOR TO
BEGINNING CONSTRUCTION. BENCHMARK IS AN EIP LOCATED WITHIN THE
COURTHOUSE SQUARE, HAVING AN ELEVATION OF 583.21'.
4. LOCATIONS OF EXISTING UTILITY LINES HAVE BEEN TAKEN FROM UTILITY RECORDS
SUPPLEMENTED BY FIELD INSPECTIONS AND SHOULD INDICATE IN GENERAL THE TYPE
OF UNDERGROUND FACILITIES NOW IN SERVICE. HOWEVER, LOCATIONS SHOWN ARE
NOT GUARANTEED AND ANY FURTHER DEVELOPERS OR CONTRACTORS SHOULD NOT
ONLY MAKE SUBSURFACE INVESTIGATIONS BUT SHOULD ALSO ALLOW FOR
CONTINGENCIES WHICH MIGHT ARISE BY REASON OF ENCOUNTERING UNRECORDED
LINES OR LINES BEING IN DIFFERENT LOCATIONS THAN INDICATED ON THIS PLAT.
5. COORDINATE ALL ELECTRICAL LINE RELOCATION WITH DUKE PROGRESS ENERGY.
6. HORIZONTAL COORDINATES BASED ON NC GRID NAD83 AND ELEVATIONS BASED ON
NAVD88 DATUM.
7. ALL DISTANCES ARE HORIZONTAL GROUND.
8. AREA BY COORDINATE COMPUTATION.
9. SURVEY INFORMATION FROM THE SURVEYOR OF RECORD, LKC ENGINEERING, PLLC;
JEFFREY L. GREEN, PLS, LIC. # L-3972; 140 AQUA SHED CT, ABERDEEN, NC 28315, TEL
#: 910-420-1437.
( IN FEET )
GRAPHIC SCALE
FULL SIZE SHEET 24"x36"
30 30 6015
C ar th ag e, N o rt h C ar o li n a
C A
R T H
A G
E D
O W
N T O
W N
R
EV
IT
A
LI
Z A
T
IO
N
A q u a
Sh ed
C o u rt
Su rv ey in g Li ce n se
N o P-
La nd sc ap e Ar ch ite ct ur e En gi ne er in g O
.4
.1
F:
.6
.0
A b er d ee n N
C lk ce n g in ee ri n g .c o m
LK
C
E n g in ee ri n g p ll c
BYDATESYM. DESCRIPTION
REVISIONS
DATE:
DESIGNED:
DRAWN:
CHECKED:
NO.
ELC
9 5
1 58
9 5
2 571
CP
CP
EM
EM
EM
ELC
9 5
1 58
9 5
2 571
CP
CP
EM
PHASE 9
PHASE 8
PHASE 7
PHASE 6
PHASE 5
PHASE 1
PHASE 4
PHASE 3PHASE 2
PHASE 1
PHASE 9
R
AY
S T
MONROE ST
(NC HWY 27)
R
AY
S T
M
AR
TI
N
S T
MONROE
(NC HWY 2
M C
N
EI
LL
S
T M
C N
EI
LL
S T
MOORE
COUNTY
HISTORIC
COURTHOUSE
MCREYNOLDS ST(NC HWY 27)
582.42 582.80 583.09
582.78
TC
583.31
TC
583.18
584.15
TC
583.85
585.32
582.06
581.55
584.65
TC
581.00
579.77
581.00
TC
579.77
579.00
579.65
578.42 TC
578.00 BC
579.61 579.00
585.00
585.00
583.96 584.67
584.95
585.73
580.87
579.73 579.94
581.55 581.77
577.57
577.94
581.82
580.87 582.84
582.95 584.99 585.02
583.61 584.05583.02
582.91
580.60
580.23
582.84
DI 583.78
DI
582.90 TS
582.50 BS
583.43 TS
582.83 BS
584.30 TS
582.98 BS
585.28 TS
583.78 BS
579.78
580.78 TS
580.39 BS
581.00
TC
580.30
TC 581.47
TC
582.89
583.00
583.11
583.11
583.34 582.76
TC 584.97 584.25
TC
583.84 584.28
585.08
585.10 585.20
585.31
585.22
580.53
580.77
579.28579.28
578.07 577.76 577.12 577.08
576.05 575.79 575.09
574.86
573.85 573.68
572.77 572.35 570.95 571.09
570.76577.47
578.22
TC
578.47
TC 577.14
TC
576.88
TC
575.95
TC 575.69
TC
574.73
TC
574.50
TOC
573.74
TC
573.51
TC
572.64
TC
572.41
TC
571.49
TC
571.39
571.84
TC
571.00
580.24 579.96
578.71 BS
578.71 BS 576.37
575.98
576.31
575.07 574.83
574.55
574.01 572.29 571.83 571.57 570.46
570.20 569.65
569.22
567.74 567.66
569.14
576.43
TC
575.93
576.13 575.30
574.81
TC
575.10
574.00
TC
573.64
574.24
572.53
TC
572.22
572.52
570.00
581.73
581.35
581.05
581.23 572.06 571.80 570.69
570.43574.60 576.32
578.45
TC
578.19
TC
575.90
578.63 BS
578.52 BS
579.76
TC580.04
584.39
584.22
584.43 584.46
583.99 583.61 583.55
583.44
578.72 TC
578.30 BC
579.50 TC
579.00 BC
582.46
581.82
TC
581.65
TC
581.88
DI
581.75
581.87
581.94
583.23
582.98
DI
585.73
585.39 TS
584.45 BS 585.05
585.43
585.33
583.64
584.64
584.28
584.63
584.64
583.00
DI
583.91
585.00
585.18
585.00
TC
585.08
584.35
584.22
584.39
584.92
TC
584.55
584.40
584.58
585.75
TOP OF
WALL
583.32
TC
584.27
TC
585.30
DI
585.30
DI
585.50
HP
585.50
585.50 585.25
584.85
585.07
585.27
585.30
585.30
582.95
DI
583.44 583.12
DI
583.44
583.44
583.37
583.18
583.33 583.45
584.43
584.07
DI
583.23
TR 583.38
581.66
BR
585.18
585.18
585.14
585.43
585.32
585.32
585.04
DI585.44
583.59 583.64
583.03
DI
583.82
584.55
582.67
582.52
DI
584.45
584.42
582.84
582.41
583.17
583.28
582.80
DI
583.37
583.07
TC
583.93
583.07
582.54
582.73
582.78
584.81
TC
582.00
585.02
583.50 583.70 583.58
583.38
583.61
583.03
DI
583.20
584.20
584.20584.30
584.30
582.78
582.97
583.38 583.47 583.48
583.07 583.12
582.89 582.80
581.61
581.61
581.68
581.78
581.68
581.78
581.95
581.80
581.83 581.94
581.84
584.94
TOP OF
WALL
582.12
582.75
583.04
582.91
583.17
583.21
583.50
583.22
DI
583.50
583.50
585.00
TOP OF
WALL
581.58
581.27
580.47
580.24
580.13
582.51
TC 581.72
DI
582.05
582.00
582.05
582.32
TOP OF
WALL
581.83
584.27 583.72
584.10
579.04
579.04 TS
578.33 BS
577.79
577.49 TS
576.99 BS
576.88
576.77 TS
575.80 BS
575.87
575.61 TS
574.61 BS
574.92
574.70 TS
573.62
573.69
573.52 TS
572.52 BS
572.61
572.19 TS
571.40 BS
580.97
581.28
584.52
SPILLWAY
584.20
SPILLWAY
583.78
SPILLWAY
583.29
SPILLWAY
582.84
SPILLWAY
584.36
DI
584.04
DI
583.62
DI
583.13
DI
582.68
DI
584.24
DI
584.40
SPILLWAY
583.39
DI
582.50
DI
582.66
SPILLWAY
584.04
581.66
BR
581.60 581.80
581.60
DI
581.33
LP
582.54 TS
581.52 BS
582.87
581.5
581.19
570.10
586.90
TOP OF
WALL
582.38 582.43
585.25
TOP OF
WALL
584.09
TOP OF
WALL
583.42
583.55
SPILLWAY
583.53
583.49
583.83
TC
583.95
583.04
582.75
6" WALL
TRANSITION
584.59
TOP OF
WALL
585.60
585.70
581.44 TS
581.09 BS
582.40
582.12
582.40
582.70
582.98
582.50
DI582.25
DI
582.33
DI
583.28
DI
583.03
DI
583.33
583.40 583.51
584.57
INLET
CURB CUT
585.03
INLET
CURB CUT
585.53
INLET
CURB CUT
584.43
INLET
CURB CUT 584.02
INLET
CURB CUT
583.72
INLET
CURB CUT
583.51
INLET
CURB CUT
582.89
INLET
CURB CUT
582.83
INLET
CURB CUT
582.96
INLET
CURB CUT
583.21
INLET
CURB CUT
583.40
INLET
CURB CUT
583.47
INLET
CURB CUT
583.95
INLET
CURB CUT
584.01
INLET
CURB CUT
584.34
INLET
CURB CUT
584.37
INLET
CURB CUT584.38
INLET
CURB CUT
584.61
INLET
CURB CUT
584.72
INLET
CURB CUT584.98
INLET
CURB CUT
585.54
INLET
CURB CUT
574.21 TC
573.82 BC
572.12 TC
571.76 BC
581.83582.49
INLET
CURB CUT
585.50
585.40
585.40
578.00
578.50 579.57
579.05 578.95
583.83
583.40
DI
583.67
583.96 584.15
584.52
583.90
DI
585.00
TC
581.49
582.54 TS
581.52 BS
581.80
581.93
TC
581.43
DI
583.17 582.83
583.27
TC
584.52
584.28
584.28
584.81
584.44
584.55
583.48
584.51
583.37
583.39
583.51
583.11
DI
583.27
INLET
CURB CUT
585.30
582.75 TC
582.42 BC
581.80
581.62
581.68
INLET
CURB CUT
581.08
DI
585.07
584.85
584.38
584.77
TC
583.97 TC
583.64 BC
583.56 TC
583.23 BC
583.21
578.42 TC
578.00 BC
578.74
579.77
579.54
579.63 TC
579.13 BC
579.51 TC
570.42 TC
570.00 BC
570.20 TC
569.78 BC
570.70571.06 TC
570.56 BC
570.61 570.45
571.18
569.14 569.14
583.34
INLET
CURB CUT
583.62
INLET
CURB CUT
0 57
4 57
7 57
PHASE 1
97 LF 15" RCP @ 0.52%
68 LF 15" RCP @ 1.55% 96 LF 15" RCP @ 0.52%
27 LF 15" RCP @ 1.85%
88 LF 15" RCP @ 0.50%
52 LF 15" RCP @ 0.50%
23 LF 15" RCP @ 0.52%
26 LF 15" RCP @ 3.89%
L
F
" R
CP
.5 7%
49 LF 15" RCP @ 1.42%
48 LF 15" RCP @ 0.52%
42 LF 15" RCP @ 0.55%
42 LF 15" RCP @ 0.60%
CI-4
RIM: 585.00
15" INV OUT: 582.00 (SW)
CI-5
RIM: 585.00
15" INV IN: 580.65 (NE)
15" INV OUT: 580.55 (SE)
CI-3
RIM: 584.00
15" INV IN: 578.00 (NW)
CI-6
RIM: 584.00
15" INV IN: 579.50 (NW)
15" INV OUT: 579.60 (SE)
15" INV OUT: 579.00 (SW)
CI-9
RIM: 582.94
15" INV IN: 579.90 (SW)
CI-7
RIM: 583.00
15" INV IN: 579.10 (NW)
15" INV IN: 579.70 (NE)
CI-8
RIM: 583.00
15" INV OUT: 579.50 (SE)
SDMH-1
RIM: 581.60
15" INV IN: 578.50 (NE)
15" INV IN: 578.50 (NW)
CI-2
RIM: 581.52
15" INV OUT: 578.50 (SE)
CI-1
RIM: 577.54
CI-11
RIM: 577.67
15" INV IN: 566.48 (E)
CI-12
RIM: 576.79
15" INV IN: 566.70 (SE)
15" INV OUT: 566.60 (W)
CI-14
RIM: 570.53
15" INV OUT: 567.50 (NW)
CI-13
RIM: 574.22
15" INV IN: 567.06 (SE)
15" INV OUT: 566.96 (NW)
CI-15
RIM: 571.96
EX.-DB-01
RIM: 583.00
15" INV OUT: 580.00 (SW)
DB-12
RIM: 583.00
15" INV OUT: 580.60 (NE)
DB-3
RIM: 585.00
15" INV IN: 581.75 (NE)
15" INV OUT: 581.65 (SW)
DB-2
RIM: 585.00
15" INV IN: 581.00 (NE)
15" INV OUT: 580.90 (SW)
CI-10
RIM: 582.00
D
RA
IN
AG
E
PL
AN
OCTOBER, 2025
MFL
JDM
C-5.0
Fi le
: L
KJ
D
-2 5.
C ar th ag e
D ow nt ow n St re et sc ap es \8
D ra w in gs
\8
D es ig n
D ra w in gs \0
Ci vi l\
KJ
D
-2 5.
C
-3 .0
D
RA
IN
GE
.d w g, B y:
S al az ar , P lo tt ed
Tu e
Fe b
, 2 at
:2 6p m
( IN FEET )
GRAPHIC SCALE
FULL SIZE SHEET 24"x36"
30 30 6015
C ar th ag e, N o rt h C ar o li n a
C A
R T H
A G
E D
O W
N T O
W N
R
EV
IT
A
LI
Z A
T
IO
N
A q u a
Sh ed
C o u rt
Su rv ey in g Li ce n se
N o P-
La nd sc ap e Ar ch ite ct ur e En gi ne er in g O
.4
.1
F:
.6
.0
A b er d ee n N
C lk ce n g in ee ri n g .c o m
LK
C
E n g in ee ri n g p ll c
BYDATESYM. DESCRIPTION
REVISIONS
DATE:
DESIGNED:
DRAWN:
CHECKED:
NO.
NOTES:
1. ALL GENERAL NOTES, ABBREVIATIONS, SYMBOLS, AND OTHER INFORMATION
INDICATED ON SHEET C-01 SHALL APPLY TO THIS PLAN.
2. THE PURPOSE OF THE PLAN IS FOR INFORMATIONAL PURPOSES ONLY. THOUGH THIS
PLAN IS FROM AN ACTUAL FIELD SURVEY IT IS NOT AND SHOULD NOT BE CONSIDERED
A RECORDABLE DOCUMENT.
3. ALL ELEVATIONS SHOWN ARE IN REFERENCE TO THE BENCHMARK AND MUST BE
VERIFIED BY THE GENERAL CONTRACTOR WITH THE SURVEYOR OF RECORD PRIOR TO
BEGINNING CONSTRUCTION. BENCHMARK IS AN EIP LOCATED WITHIN THE
COURTHOUSE SQUARE, HAVING AN ELEVATION OF 583.21'.
4. LOCATIONS OF EXISTING UTILITY LINES HAVE BEEN TAKEN FROM UTILITY RECORDS
SUPPLEMENTED BY FIELD INSPECTIONS AND SHOULD INDICATE IN GENERAL THE TYPE
OF UNDERGROUND FACILITIES NOW IN SERVICE. HOWEVER, LOCATIONS SHOWN ARE
NOT GUARANTEED AND ANY FURTHER DEVELOPERS OR CONTRACTORS SHOULD NOT
ONLY MAKE SUBSURFACE INVESTIGATIONS BUT SHOULD ALSO ALLOW FOR
CONTINGENCIES WHICH MIGHT ARISE BY REASON OF ENCOUNTERING UNRECORDED
LINES OR LINES BEING IN DIFFERENT LOCATIONS THAN INDICATED ON THIS PLAT.
5. COORDINATE ALL ELECTRICAL LINE RELOCATION WITH DUKE PROGRESS ENERGY.
6. HORIZONTAL COORDINATES BASED ON NC GRID NAD83 AND ELEVATIONS BASED ON
NAVD88 DATUM.
7. ALL DISTANCES ARE HORIZONTAL GROUND.
8. AREA BY COORDINATE COMPUTATION.
9. SURVEY INFORMATION FROM THE SURVEYOR OF RECORD, LKC ENGINEERING, PLLC;
JEFFREY L. GREEN, PLS, LIC. # L-3972; 140 AQUA SHED CT, ABERDEEN, NC 28315, TEL
#: 910-420-1437.
gat
ELC
CP
CP
EM
EM
EM
ELC
CP
CP
EM
PHASE 9
PHASE 8
PHASE 7
PHASE 6
PHASE 5
PHASE 1
PHASE 4
PHASE 3PHASE 2
PHASE 1
PHASE 9
R
AY
S T
MONROE ST
(NC HWY 27)
R
AY
S T
M
AR
TI
N
S T
M C
N
EI
LL
S
T M
C N
EI
LL
S T
MOORE
COUNTY
HISTORIC
COURTHOUSE
MCREYNOLDS ST(NC HWY 27)
582.42 582.80 583.09
582.78
TC
583.31
TC
583.18
584.15
TC
583.85
585.32
582.06
581.55
584.65
TC
581.00
579.77
581.00
TC
579.77
579.00
579.65
578.42 TC
578.00 BC
579.61 579.00
585.00
585.00
583.96 584.67
584.95
585.73
580.87
579.73 579.94
581.55 581.77
577.57
577.94
581.82
580.87 582.84
582.95 584.99 585.02
583.61 584.05583.02
582.91
580.60
580.23
582.84
DI 583.78
DI
582.90 TS
582.50 BS
583.43 TS
582.83 BS
584.30 TS
582.98 BS
585.28 TS
583.78 BS
579.78
580.78 TS
580.39 BS
581.00
TC
580.30
TC 581.47
TC
582.89
583.00
583.11
583.11
583.34 582.76
TC 584.97 584.25
TC
583.84 584.28
585.08
585.10 585.20
585.31
585.22
580.53
580.77
579.28579.28
578.07 577.76 577.12 577.08
576.05 575.79 575.09
574.86
573.85 573.68
572.77 572.35 570.95 571.09
570.76577.47
578.22
TC
578.47
TC 577.14
TC
576.88
TC
575.95
TC 575.69
TC
574.73
TC
574.50
TOC
573.74
TC
573.51
TC
572.64
TC
572.41
TC
571.49
TC
571.39
571.84
TC
571.00
580.24 579.96
578.71 BS
578.71 BS 576.37
575.98
576.31
575.07 574.83
574.55
574.01 572.29 571.83 571.57 570.46
570.20 569.65
569.22
567.74 567.66
569.14
576.43
TC
575.93
576.13 575.30
574.81
TC
575.10
574.00
TC
573.64
574.24
572.53
TC
572.22
572.52
570.00
581.73
581.35
581.05
581.23 572.06 571.80 570.69
570.43574.60 576.32
578.45
TC
578.19
TC
575.90
578.63 BS
578.52 BS
579.76
TC580.04
584.39
584.22
584.43 584.46
583.99 583.61 583.55
583.44
578.72 TC
578.30 BC
579.50 TC
579.00 BC
582.46
581.82
TC
581.65
TC
581.88
DI
581.75
581.87
581.94
583.23
582.98
DI
585.73
585.39 TS
584.45 BS 585.05
585.43
585.33
583.64
584.64
584.28
584.63
584.64
583.00
DI
583.91
585.00
585.18
585.00
TC
585.08
584.35
584.22
584.39
584.92
TC
584.55
584.40
584.58
585.75
TOP OF
WALL
583.32
TC
584.27
TC
585.30
DI
585.30
DI
585.50
HP
585.50
585.50 585.25
584.85
585.07
585.27
585.30
585.30
582.95
DI
583.44 583.12
DI
583.44
583.44
583.37
583.18
583.33 583.45
584.43
584.07
DI
583.23
TR 583.38
581.66
BR
585.18
585.18
585.14
585.43
585.32
585.32
585.04
DI585.44
583.59 583.64
583.03
DI
583.82
584.55
582.67
582.52
DI
584.45
584.42
582.84
582.41
583.17
583.28
582.80
DI
583.37
583.07
TC
583.93
583.07
582.54
582.73
582.78
584.81
TC
582.00
585.02
583.50 583.70
583.58
583.38
583.61
583.03
DI
583.20
584.20
584.20584.30
584.30
582.78
582.97
583.38 583.47 583.48
583.07 583.12
582.89 582.80
581.61
581.61
581.68
581.78
581.68
581.78
581.95
581.80
581.83 581.94
581.84
584.94
TOP OF
WALL
582.12
582.75
583.04
582.91
583.17
583.21
583.50
583.22
DI
583.50
583.50
585.00
TOP OF
WALL
581.58
581.27
580.47
580.24
580.13
582.51
TC 581.72
DI
582.05
582.00
582.05
582.32
TOP OF
WALL
581.83
584.27 583.72
584.10
579.04
579.04 TS
578.33 BS
577.79
577.49 TS
576.99 BS
576.88
576.77 TS
575.80 BS
575.87
575.61 TS
574.61 BS
574.92
574.70 TS
573.62
573.69
573.52 TS
572.52 BS
572.61
572.19 TS
571.40 BS
580.97
581.28
584.52
SPILLWAY
584.20
SPILLWAY
583.78
SPILLWAY
583.29
SPILLWAY
582.84
SPILLWAY
584.36
DI
584.04
DI
583.62
DI
583.13
DI
582.68
DI
584.24
DI
584.40
SPILLWAY
583.39
DI
582.50
DI
582.66
SPILLWAY
584.04
581.66
BR
581.60 581.80
581.60
DI
581.33
LP
582.54 TS
581.52 BS
582.87
581.5
581.19
570.10
586.90
TOP OF
WALL
582.38 582.43
585.25
TOP OF
WALL
584.09
TOP OF
WALL
583.42
583.55
SPILLWAY
583.53
583.49
583.83
TC
583.95
583.04
582.75
6" WALL
TRANSITION
584.59
TOP OF
WALL
585.60
585.70
581.44 TS
581.09 BS
582.40
582.12
582.40
582.70
582.98
582.50
DI582.25
DI
582.33
DI
583.28
DI
583.03
DI
583.33
583.40 583.51
584.57
INLET
CURB CUT
585.03
INLET
CURB CUT
585.53
INLET
CURB CUT
584.43
INLET
CURB CUT 584.02
INLET
CURB CUT
583.72
INLET
CURB CUT
583.51
INLET
CURB CUT
582.89
INLET
CURB CUT
582.83
INLET
CURB CUT
582.96
INLET
CURB CUT
583.21
INLET
CURB CUT
583.40
INLET
CURB CUT
583.47
INLET
CURB CUT
583.95
INLET
CURB CUT
584.01
INLET
CURB CUT
584.34
INLET
CURB CUT
584.37
INLET
CURB CUT584.38
INLET
CURB CUT
584.61
INLET
CURB CUT
584.72
INLET
CURB CUT584.98
INLET
CURB CUT
585.54
INLET
CURB CUT
574.21 TC
573.82 BC
572.12 TC
571.76 BC
581.83582.49
INLET
CURB CUT
585.50
585.40
585.40
578.00
578.50 579.57
579.05 578.95
583.83
583.40
DI
583.67
583.96 584.15
584.52
583.90
DI
585.00
TC
581.49
582.54 TS
581.52 BS
581.80
581.93
TC
581.43
DI
583.17 582.83
583.27
TC
584.52
584.28
584.28
584.81
584.44
584.55
583.48
584.51
583.37
583.39
583.51
583.11
DI
583.27
INLET
CURB CUT
585.30
582.75 TC
582.42 BC
581.80
581.62
581.68
INLET
CURB CUT
581.08
DI
585.07
584.85
584.38
584.77
TC
583.97 TC
583.64 BC
583.56 TC
583.23 BC
583.21
578.42 TC
578.00 BC
578.74
579.77
579.54
579.63 TC
579.13 BC
579.51 TC
570.42 TC
570.00 BC
570.20 TC
569.78 BC
570.70571.06 TC
570.56 BC
570.61 570.45
571.18
569.14 569.14
583.34
INLET
CURB CUT
583.62
INLET
CURB CUT
0 57
4 57
7 57
PHASE 1
1- FIRE HYDRANT ASSEMBLY
(RELOCATED)
1- FIRE HYDRANT ASSEMBLY
(RELOCATED)
1- GATE VALVE
(RELOCATED)
1- GATE VALVE
(RELOCATED)
1- FIRE HYDRANT ASSEMBLY
(RELOCATED)
UT
IL
IT
Y
PL
AN
OCTOBER, 2025
MFL
JDM
C-9.0
Fi le
: L
KJ
D
-2 5.
C ar th ag e
D ow nt ow n St re et sc ap es \8
D ra w in gs
\8
D es ig n
D ra w in gs \0
Ci vi l\
KJ
D
-2 5.
C
-9 .0
U
TI
LI
TY
.d w g, B y:
S al az ar , P lo tt ed
Tu e
Fe b
, 2 at
:2 6p m
( IN FEET )
GRAPHIC SCALE
FULL SIZE SHEET 24"x36"
30 30 6015
C ar th ag e, N o rt h C ar o li n a
C A
R T H
A G
E D
O W
N T O
W N
R
EV
IT
A
LI
Z A
T
IO
N
A q u a
Sh ed
C o u rt
Su rv ey in g Li ce n se
N o P-
La nd sc ap e Ar ch ite ct ur e En gi ne er in g O
.4
.1
F:
.6
.0
A b er d ee n N
C lk ce n g in ee ri n g .c o m
LK
C
E n g in ee ri n g p ll c
BYDATESYM. DESCRIPTION
REVISIONS
DATE:
DESIGNED:
DRAWN:
CHECKED:
NO.
NOTES:
1. ALL GENERAL NOTES, ABBREVIATIONS, SYMBOLS, AND OTHER INFORMATION
INDICATED ON SHEET C-01 SHALL APPLY TO THIS PLAN.
2. THE PURPOSE OF THE PLAN IS FOR INFORMATIONAL PURPOSES ONLY. THOUGH THIS
PLAN IS FROM AN ACTUAL FIELD SURVEY IT IS NOT AND SHOULD NOT BE CONSIDERED
A RECORDABLE DOCUMENT.
3. ALL ELEVATIONS SHOWN ARE IN REFERENCE TO THE BENCHMARK AND MUST BE
VERIFIED BY THE GENERAL CONTRACTOR WITH THE SURVEYOR OF RECORD PRIOR TO
BEGINNING CONSTRUCTION. BENCHMARK IS AN EIP LOCATED WITHIN THE
COURTHOUSE SQUARE, HAVING AN ELEVATION OF 583.21'.
4. LOCATIONS OF EXISTING UTILITY LINES HAVE BEEN TAKEN FROM UTILITY RECORDS
SUPPLEMENTED BY FIELD INSPECTIONS AND SHOULD INDICATE IN GENERAL THE TYPE
OF UNDERGROUND FACILITIES NOW IN SERVICE. HOWEVER, LOCATIONS SHOWN ARE
NOT GUARANTEED AND ANY FURTHER DEVELOPERS OR CONTRACTORS SHOULD NOT
ONLY MAKE SUBSURFACE INVESTIGATIONS BUT SHOULD ALSO ALLOW FOR
CONTINGENCIES WHICH MIGHT ARISE BY REASON OF ENCOUNTERING UNRECORDED
LINES OR LINES BEING IN DIFFERENT LOCATIONS THAN INDICATED ON THIS PLAT.
5. COORDINATE ALL ELECTRICAL LINE RELOCATION WITH DUKE PROGRESS ENERGY.
6. HORIZONTAL COORDINATES BASED ON NC GRID NAD83 AND ELEVATIONS BASED ON
NAVD88 DATUM.
7. ALL DISTANCES ARE HORIZONTAL GROUND.
8. AREA BY COORDINATE COMPUTATION.
9. SURVEY INFORMATION FROM THE SURVEYOR OF RECORD, LKC ENGINEERING, PLLC;
JEFFREY L. GREEN, PLS, LIC. # L-3972; 140 AQUA SHED CT, ABERDEEN, NC 28315, TEL
#: 910-420-1437.
D-01
D R A
IN
A
G E
D
ET
A
IL
S
Fi le
L:
\K
JD
-2 .0
C ar th ag e
D o w n to w n S tr ee ts ca p es
\8 D ra w in g s\
D es ig n D ra w in g s\
C iv il \K
JD
-2
.0
D
ET
A
IL
S.
d w g B y:
S al az ar
Pl o tt ed T u e
Fe b a t :2 p m
3 4
GRATE INLET
NOT TO SCALE
1'-7"1'-7"
'-7
'-7
STORM
DRAIN PIPESTORM
DRAIN PIPE
CONCRETE
APRON
CONCRETE
APRON
CONCRETE
APRON
6" 6"
6"
V A
R
IE
S
SE
E
N C
D O
T D
W G
.1
SH
EE
T
S
A N
D
4'-0"
3'-2"
NOTES:
1. ALL MATERIALS, DIMENSIONS AND CONSTRUCTION SHALL
CONFORM TO NCDOT STD. DWG. 840.17 BRICK OR
CONCRETE DROP INLETS TYPE "A".
M
IN
V A
R
IE
S
SE
E
PL
A
N S
M
IN
NOT TO SCALE
24"x36" FRAME AND GRATE
'-3
1 4
1'-41 2"
2"
1'-75 8"
1'-41 2"
2"
1'-75 8"
1'-75 8" 1'-75
8"
2"1 3 16"
PLAN VIEW
SECTION VIEW FRONT
SECTION VIEW SIDE
3'-6"
'-6
"3'-13
4"
3'-6"
2'-13 4"
2'-6"
1"
1" 1"
SECTION VIEW SIDE
SECTION VIEW FRONT
1" 2
PLAN VIEW
NOT TO SCALE
STORM DRAIN MANHOLE
8" SOLID CONCRETE
BRICK OR PRECAST
CONCRETE STRUCTURE
ALL STEPS IN MANHOLES
SHALL BE COPOLYMER
POLYPROPYLENE PLASTIC,
REINFORCED WITH 12" GRADE
60 REINFORCEMENT MANHOLE
STEPS @ 16" O.C. IF DEPTH
IS MORE THAN 3'-0"
6"x6" #6 WELDED
WIRE MESH (TYP.)
24" MANHOLE RING
AND COVER - SEE
DETAIL
TAPERED
LIFTING HOLES
48"
NOTES:
1. REINFORCEMENT TO MEET
ASTM C-478-72
2. WIRE MESH: ASTM A-1 85-69
'-0
O
R L
ES
S
V A
R
IE
S '-0
'-0
O R
'-0
'-0
M
A X W
IT
H
P
SI
P
R
EC
A
ST
C O
N C
R
ET
E
12" MAX.
#4 REBAR @
12" O.C.E.W.
STORM DRAIN PIPE
NOT TO SCALE
24" STORM DRAIN MANHOLE RING AND COVER
RING
SUPPORTS (TYP.)
23 12"
22"
25"
33 14" 1 2
FLANGE
RING
2-1" PICK
INDENTIONS
24" CAST IRON
RING AND COVER
H-20 LOAD RATED
C ar th ag e, N o rt h C ar o li n a
C A
R T H
A G
E D
O W
N T O
W N
R
EV
IT
A
LI
Z A
T
IO
N
A q u a
Sh ed
C o u rt
Su rv ey in g Li ce n se
N o P-
La nd sc ap e Ar ch ite ct ur e En gi ne er in g O
.4
.1
F:
.6
.0
A b er d ee n N
C lk ce n g in ee ri n g .c o m
LK
C
E n g in ee ri n g p ll c
BYDATESYM. DESCRIPTION
REVISIONS
DATE:
DESIGNED:
DRAWN:
CHECKED:
NO.
OCTOBER, 2025
MFL
JDM
NOT TO SCALE
CURB INLET
POINT OF "TOP
OF CURB" ELEV.
POINT OF "TOP
OF CURB" ELEV.
POINT OF
"RIM ELEV."
2'-2"
2'-2"5 /8
BACK OF
CURB
EXTENSION FOR
30" PIPES AND
LARGER
PAVEMENT
PAVEMENT
6" 6"
6" 6"
6" 6"
ALL STEPS IN MANHOLES
SHALL BE COPOLYMER
POLYPROPYLENE PLASTIC,
REINFORCED WITH 12"
GRADE 60 REINFORCED
MANHOLE STEPS @ 16"
O.C. IF DEPTH IS MORE
THAN 3'-0"
V A
R
IE
S
SE
E
PL
A
N S
V A
R
IE
S
SE
E
PL
A
N S
PRECAST
CONC. STRUCTURE
PRECAST
CONCRETE
STRUCTURE
12"-24" STORM
DRAIN PIPE
30" OR LARGER
STORM DRAIN PIPE
STORM
DRAIN PIPE
STORM
DRAIN PIPE
VARIES
'-2
"V A
R
IE
S
SE
E
N C
D O
T D
W G
.0
-8
.0
PLAN VIEW SIDE VIEW FOR 12"-24"
REBAR
FRONT VIEW
SIDE VIEW FOR 30" AND LARGER
POINT OF
"RIM ELEV."
REBAR
NOTES:
1. ALL MATERIALS, DIMENSIONS AND CONSTRUCTION SHALL
CONFORM TO NCDOT STD. DWGS. 840.01 AND 840.02
BRICK OR CONCRETE CATCH BASINS.
NOT TO SCALE
STORM DRAIN PIPE NOTES
STORM DRAIN PIPE NOTES:
1. ALL STORM DRAINAGE SHALL BE RCP UNLESS OTHERWISE NOTED ON PLANS.
2. STORM DRAINAGE PIPING IN ANY NCDOT RIGHT-OF-WAY SHALL BE CLASS 3 OR BETTER
AND STAMPED FOR NCDOT.
3. STORM DRAINAGE PIPING IN NON-NCDOT RIGHT-OF-WAY UNDER PAVEMENT SHALL BE
CLASS 3 OR BETTER, STAMP NOT REQUIRED.
4. CLASS 4 STORM DRAINAGE PIPING SHALL BE UTILIZED WHEN THERE IS TWO FEET OF
COVER OR LESS. ONE FOOT MINIMUM OF COVER IS REQUIRED.
STORM DRAIN PIPE SEPARATION NOTES:
1. THE MINIMUM VERTICAL CLEARANCE BETWEEN STORM DRAINAGE AND SANITARY
SEWER LINES SHALL BE 24-INCHES UNLESS DUCTILE IRON IS SPECIFIED FOR THE
SANITARY SEWER LINES.
2. STORM DRAINAGE PIPE HAVING WATER MAINS CROSSING OVER, OR UNDER
MUST MAINTAIN A VERTICAL SEPARATION OF AT LEAST 18-INCHES.¬ IN
ADDITION, IF A WATER MAIN MUST CROSS UNDER A STORM DRAINAGE PIPE,
THE WATER MAIN SHALL BE MADE OF DUCTILE IRON FOR A MINIMUM OF 10
FEET ON BOTH SIDES OF THE CROSSING.
D-02
U T
IL
IT
Y D
ET
A
IL
S
Fi le
L:
\K
JD
-2 .0
C ar th ag e
D o w n to w n S tr ee ts ca p es
\8 D ra w in g s\
D es ig n D ra w in g s\
C iv il \K
JD
-2
.0
D
ET
A
IL
S.
d w g B y:
S al az ar
Pl o tt ed T u e
Fe b a t :2 p m
C ar th ag e, N o rt h C ar o li n a
C A
R T H
A G
E D
O W
N T O
W N
R
EV
IT
A
LI
Z A
T
IO
N
A q u a
Sh ed
C o u rt
Su rv ey in g Li ce n se
N o P-
La nd sc ap e Ar ch ite ct ur e En gi ne er in g O
.4
.1
F:
.6
.0
A b er d ee n N
C lk ce n g in ee ri n g .c o m
LK
C
E n g in ee ri n g p ll c
BYDATESYM. DESCRIPTION
REVISIONS
DATE:
DESIGNED:
DRAWN:
CHECKED:
NO.
OCTOBER, 2025
MFL
JDM
File details come from the government source that posted it. Updated .