Kennel Specification.pdf

PDF 2 MB Posted

Attached to
Adoption Room Renovation
Solicitation number
81217
Issued by
Hanover County, Virginia

About this file

This document contains the specifications for the Kennel Room as part of the Hanover County Animal Control project. The project requires the furnishing and installation of kennels according to the attached specifications. The scope includes details on the kennel dimensions, finishes, accessories, and installation requirements. The contract opportunity is for the Adoption Room Renovation project in Hanover County, Virginia. The request is for qualified contractors to provide unit pricing for the specified kennels, including all materials, labor, and incidentals to fully complete the project.

The pricing terms and other salient details are not explicitly stated in the provided documentation. However, the document indicates that the project is being solicited by Hanover County, and the unit price should cover the full scope of work to furnish and install the kennels per the specifications.

View the file

Other files

File Type Posted
Kennel Specification.pdf PDF
Adoption Room Renovation.pdf PDF
Adoption Room Renovation.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

www.midmark.com design@midmark.com Phone: 1-800-MIDMARK

Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7

4/16Drawing Template: - Revision: - Change Order: -

Signed Drawings Required To Process Order

(Signature) (Date)

WALL TO WALL 378" [31'-6"]

W

AL

L

TO

W

AL

L

[2 9'

-2

40"

38"

150"

PLAN

DIRECTIONS

W E N

S

WALL TO GUTTER 15'-6" WALL TO GUTTER 15'-6"

GUTTER 6"

VERIFY SLOPEVERIFY SLOPE

Version: 1

Field Measurements Approved

Floor Plan View

Kennel Room

Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7

5/16Drawing Template: - Revision: - Change Order: -www.midmark.com design@midmark.com Phone: 1-800-MIDMARK

Signed Drawings Required To Process Order

(Signature) (Date)

72.25"

60.25"73.00" 72.25"

Version: 1

Room Plan View

RBXX00000-XXX | Rest Bench QTY: 8

TCXX-XX00000-XXX | Top Cover QTY: 8

6/16Drawing Template: - Revision: - Change Order: -www.midmark.com design@midmark.com Phone: 1-800-MIDMARK

Kennel Room

Signed Drawings Required To Process Order

(Signature) (Date)

FRP

SG37-RNNDNYW-245

FRP

SG37-RNNDNYP-245

FRP

SG37-RNNDNYP-245

FRPFRP

SF48-RLNDSYP-245

FRPFRP

SF48-RLNDSYP-245

FRPFRP

SF48-RLNDSYP-245

FRPFRP

SF48-RLNDSYP-245

FRPFRP

SF48-RLNDSYW-245

34.75"

36.50"

34.75"

37.00"

34.75"

37.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

47.50"

76.38"

350.00"

Version: 1

Accessories:

245-Sky, 929-Stainless Steel

350" x 73" x 75"

Finish:

Dimensions:

Threshold:

Note: Field Measurement Approved

Not Included www.midmark.com

Phone: 1-800-MIDMARK

Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7

Kennel Room 7/16Drawing Template: - Revision: - Change Order: -

Signed Drawings Required To Process Order

(Signature) (Date)

Kennel 3D View

Signed Drawings Required To Process Order

(Signature) (Date) www.midmark.com design@midmark.com Phone: 1-800-MIDMARK

Kennel Room

GPSK-8164000-XXX | Support Post QTY: 1

RBXX00000-XXX | Rest Bench QTY: 6

TCXX-XX00000-XXX | Top Cover QTY: 6

Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7

8/16Drawing Template: - Revision: - Change Order: -

FRP FRP

SF48-LRNDSYW-245

FRP FRP

SF48-LRNDSYP-245

FRP FRP

SF48-LRNDSYP-245

FRP FRP

SF48-LRNDSYP-245

FRP FRP

SF48-LRNDSYP-245

FRP FRP

SF48-LRNDSYP-245

45.75" [30.25" Gate]

47.63"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

50.88"

76.38"

290.50"

Threshold: Not Included

290.5" x 73" x 75"

Version: 1

Dimensions:

Finish:

Field Measurement ApprovedNote:

245-Sky, 929-Stainless Steel

Accessories:

GPSK-8164000-XXX | Support Post QTY: 1

RBXX00000-XXX | Rest Bench QTY: 6

TCXX-XX00000-XXX | Top Cover QTY: 6

Kennel Room

Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7

9/16Drawing Template: - Revision: - Change Order: -

Signed Drawings Required To Process Order

(Signature) (Date) www.midmark.com design@midmark.com Phone: 1-800-MIDMARK

FRPFRP

SF48-RLNDSYW-245

FRPFRP

SF48-RLNDSYP-245

FRPFRP

SF48-RLNDSYP-245

FRPFRP

SF48-RLNDSYP-245

FRPFRP

SF48-RLNDSYP-245

FRPFRP

SF48-RLNDSYP-245

45.75" [30.25" Gate]

47.63"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

50.88"

76.38"

290.50"

Finish:

Not Included

Field Measurement Approved

Dimensions:

245-Sky, 929-Stainless Steel

Threshold:

Version: 1

Note:

Accessories:290.5" x 72.25" x 75"

(Signature) (Date) www.midmark.com design@midmark.com Phone: 1-800-MIDMARK

Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7

10/16Drawing Template: - Revision: - Change Order: -

Kennel Room

(Signature) (Date) www.midmark.com design@midmark.com Phone: 1-800-MIDMARK

11/16Drawing Template: - Revision: - Change Order: -

GPSK-8164000-XXX | Support Post QTY: 2

RBXX00000-XXX | Rest Bench QTY: 5

TCXX-XX00000-XXX | Top Cover QTY: 5

Kennel Room

Project Name: Hanover County Animal Control Project #: A236616 Phase: 01 Rev: 7

FRP FRP

SF48-LRNDSYP-245

FRP FRP

SF48-LRNDSYP-245

FRP FRP

SF48-LRNDSYP-245

FRP FRP

SF48-LRNDSYP-245

FRP FRP

SF48-LRNDSYP-245

45.75" [30.25" Gate]

50.88"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

48.00"

45.75" [30.25" Gate]

50.88"

76.38"

245.75"

Dimensions:

Not Included

Version: 1

Finish:

Field Measurement Approved

245.75" x 61" x 75"

Note:

Accessories:

Threshold:

245-Sky, 929-Stainless Steel

Kennel Room www.midmark.com design@midmark.com Phone: 1-800-MIDMARK

Signed Drawings Required To Process Order

(Signature) (Date)

12/16Drawing Template: - Revision: - Change Order: -

14/16Drawing Template: - Revision: - Change Order: -

Sani-Kennel Details

* The slope information is for kennel systems using Midmark Sani-T or Sani-L systems only.

* Customization will be required if the flooring exceeds the 2” slope maximum panel allowance.

* Midmark is not responsbile for replacing products modified in the field.

Disclaimers www.midmark.com design@midmark.com

Phone: 1-800-MIDMARK

Floor Slope Wall/Floor Coving

15/16Drawing Template: - Revision: - Change Order: -

Stainless Steel

Stainless Steel

Back Panel

Stainless Steel

Side Panel

75.00"

47.25"

75.00"

60.00"

Version: 1

CAUTION! THIS PAPER REGENERATES ON EACH UPDATE. ANY MARKUPS WILL BE LOST.

Sani-Kennel Panel Views www.midmark.com

16/16Drawing Template: - Revision: - Change Order: -

Stainless Steel

Side Panel

75.00"

72.00"

Version: 1

CAUTION! THIS PAPER REGENERATES ON EACH UPDATE. ANY MARKUPS WILL BE LOST.

www.midmark.com design@midmark.com

Sani-Kennel Panel Views

File details come from the government source that posted it. Updated .