Karrh Community Center Design_ADDENDUM 1_0528.pdf
PDF 8 MB Posted
- Attached to
- Audio, Visual, and Theatrical lighting system
- Solicitation number
- PE-66723-NONST-2024-000000006
- Issued by
- Dougherty County, Georgia
About this file
This document is an Addendum for the Audio, Visual, and Theatrical Lighting System contract opportunity for the Karrh Community Center in Swainsboro, Georgia. The project will consist of sound systems, video projection, stage lighting, stage draperies, and stage rigging. The project drawings and specifications have been provided by the City of Swainsboro. Interested bidders should submit any project RFIs 10 days prior to the bid date.
The contract requires products such as back boxes, pull boxes, conduits, receptacles, speakers, projectors, screens, equipment racks, and lighting fixtures. Key quantities include 10" x 10" and 8" x 8" production panels, 20A 120VAC circuits, and multiple types of speakers. The contract does not specify any set-asides, incumbents, or funding sources. Bidders should review the detailed specifications and drawings to understand the full scope of work.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Karrh System Specifications 100_ (005).pdf | ||
| Karrh System Specifications ADDENDUM 2 100_.pdf | ||
| Addendum 2.docx | DOCX document | |
| Karrh System Specifications ADDENDUM 1 100_.pdf | ||
| Karrh Community Center Design_DESIGN_050224 R.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10" X 10" X 4" SCREW COVER PULL BOX
TWO GANG BACK BOX - MINIMUM DEPTH 3"
SINGLE GANG BACK BOX - MINIMUM DEPTH 3"
THREE GANG BACK BOX - MINIMUM DEPTH 3"
FOUR GANG BACK BOX - MINIMUM DEPTH 3"
CUSTOM BACK BOX - SEE DETAIL
FLOOR BOX7
AUDIO LOUDSPEAKER
PROJECTION SCREEN
AV EQUIPMENT RACK
FLAT PANEL DISPLAY
EQUIPMENT IDENTIFIER LEGEND
SYMBOL LEGEND
EQUIPMENT IDENTIFIER
EMPTY LOW VOLTAGE CONDUIT WITH PULL STRING. E.C. TO PROVIDE SIZE & QUANTITY INDICATED. CONDUIT TO BE (1) 1"C IF NO NOTATION GIVEN. LINE DOES NOT IMPLY HOW CONDUIT IS TO BE ROUTED. ROUTE CONDUIT AS
REQUIRED IN FIELD.
E.C. SUPPLIED CIRCUIT(S). ARROWS DENOTE QUANTITY OF CIRCUITS. CROSSMARKS INDICATE QUANTITY OF CONDUCTORS PER CIRCUIT. ALL CONDUCTORS TO BE 20A 120VAC CONDUCTORS UNLESS NOTED OTHERWISE.
ALL RUNS TO INCLUDE GROUNDING CONDUCTOR WHICH IS NOT INCLUDED IN THE CROSSMARKS. RUNS DEVOID OF CROSSMARKS ARE TO CONTAIN (2) 20A 120VAC CONDUCTORS & (1) GROUNDING CONDUCTOR UNLESS NOTED
OTHERWISE. "IG" INDICATES ISOLATED GROUNDING CONDUCTOR.
PULL BOX SUPPLIED BY E.C. SIZE AS REQUIRED. LOCATE BOX IN ACCESSIBLE AREA.
CONDUIT STUBBED INTO ACCESSIBLE SPACE ABOVE CEILING IN ROOM WHERE SYMBOL IS SHOWN, UNO
WALL-MOUNTED 20A/120V DUPLEX RECEPTACLE ON DEDICATED 20A CIRCUIT
CEILING MOUNTED 20A/120V DUPLEX RECEPTACLE ON DEDICATED 20A CIRCUIT
20A/120VAC DUPLEX RECEPTACLE ON DEDICATED 20A CIRCUIT MOUNTED IN FLOOR BOX
WALL-MOUNTED 20A/120V DUPLEX RECEPTACLE ON DEDICATED 20A CIRCUIT WITH ISOLATED GROUND ON
DEDICATED 20A CIRCUIT
CEILING MOUNTED 20A/120V DUPLEX RECEPTACLE ON DEDICATED 20A CIRCUIT WITH ISOLATED GROUND ON
DEDICATED 20A CIRCUIT
20A/120VAC DUPLEX RECEPTACLE ON DEDICATED 20A CIRCUIT WITH ISOLATED GROUND MOUNTED IN FLOOR BOX
ON DEDICATED 20A CIRCUIT
RADIO FREQUENCY TRANSMISSION SYSTEM
SHEET KEYNOTE IDENTIFIER. SEE SHEET KEYNOTE WITH CORRESPONDING NUMBER "XX". NOTES CAN BE FOUND
IN THE SHEET KEYNOTES TABLE ON PAGE WHERE IDENTIFIER APPEARS.
WALL MOUNTED DATA DROP BY OTHERS. QUANTITY SHOWN AS NEEDED.
DATA DROP MOUNTED IN FLOOR BOX BY OTHERS. QUANTITY SHOWN AS NEEDED
XXXXXX
1"C & (2) 1-1/2"C
IG
PB
IG
IG
IG
XX
X#
X#
GENERAL NOTES
1 ALL LINE VOLTAGE ELECTRICITY SHALL BE PROVIDED AND INSTALLED BY E.C.
2 ALL VOICE SERVICES, DATA SERVICES, COMPUTER NETWORKING SERVICES AND CABLING FOR SAID SERVICES SHALL BE
PROVIDED BY OTHERS.
3 ALL FREE AIR CABLING SHALL BE PLENUM RATED.
4 ALL DEVICE PLATES MOUNTED IN INTERIOR WALL SHALL HAVE A NATURAL ALUMINUM FINISH, U.N.O.
5 ALL DEVICE PLATES MOUNTED INSIDE FLOOR BOXES SHALL HAVE A NATURAL ALUMINUM FINISH, U.N.O.
6 ALL DEVICE PLATES SHALL BE STANDARD SIZE U.N.O.
ABBREVIATIONS
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AV AUDIO VISUAL
BLW CLG BELOW CEILING
BOS BOTTOM OF STEEL
CKT CIRCUIT
EC ELECTRICAL CONTRACTOR
IR INFRARED
MC METAL-CLAD
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
OFOI OWNER FURNISHED, OWNER INSTALLED
PROSC PROSCENIUM
PSC PRESENTATION SYSTEMS CONTRACTOR
RCP REFLECTED CEILING PLAN
SL STAGE LEFT
SR STAGE RIGHT
UNO UNLESS NOTED OTHERWISE
VAC VOLTS-ALTERNATING CURRENT
12 VIDEO / DATA PROJECTOR
CONVENTIONS
CIRCUIT NUMBER IDENTIFICATION (SD= STAGE DIMMER, HD=HOUSELIGHT DIMMER)
FACEPLATE IDENTIFIER AS DETAILED IN DRAWING SECTION AV300
BACK BOX IDENTIFIER (SEE BACK BOX IDENTIFIER LEGEND BELOW)
SD XX-XX
1 P3.1
LOCATION POINT OF BACKBOX
BACK BOX AND EQUIPMENT IDENTIFIER - - THE BACKBOX SIZE,
RESPONSIBILITY, AND MOUNTING HEIGHT CAN BE FOUND WITH ITS
CORRESPONDING FACEPLATE IN DRAWING SECTION AV400
LINE VOLTAGE CIRCUIT HOMERUN W/ CIRCUIT COUNT. IDENTIFIER AT END OF ARROWS INDICATES
FEEDING DEVICE.
SIZE & QUANTITY OF LOW VOLTAGE CONDUIT. PARENTHESES INDICATE QUANTITY.
1"C & (2) 1-1/2"C
SD1.112TO
13 PULL BOX
14 PRODUCTION PANEL
REVISION
DRAWING NO.
TITLE
PROJECT NUMBER
CHECKED BY
DRAWN BY
DESIGNED BY
DATE
ISSUE
54321 6
A
B
C
D
E
This document contains copyrighted material and information belonging to Stage Front Presentation Systems. Any unauthorized use, disclosure, or duplication of any of the information contained herein may result in liability under applicable laws.
6 SOUTHERN OAKS DR.
SAVANNAH, GA. 31405
PH. 912-236-1345
FAX 912-233-5350
www.sfps.net
AS
AL
AD
04/22/24
K A
R R
H
C O
M M
U N
IT
Y
C
EN
TE
R
D
ES
IG
N
SW
A
IN
SB
O R
O , G
A
AV001
LEGEND
DESIGN04/22/24
ADDENDUM 105/28/24
KARRH
SWAINSBORO, GA
PROJECT #3260
COMMUNITY CENTER DESIGN
LEGEND
Sheet List Table
SHEET
NUMBER SHEET TITLE
AV001 LEGEND
AV101 THEATER FLOOR PLAN
AV201 THEATER AV RCP
AV202 THEATER LIGHTING RCP
AV301 THEATER SECTION
AV401 PLATE DETAILS
AV402 AUDIO DETAILS
AV403 VIDEO DETAILS
AV404 EQUIPMENT RACK DETAILS
AV405 LIGHTING DETAILS
AV406 LIGHTING BATTEN DETAILS
AV701 AUDIO FLOWS 1
AV702 AUDIO FLOWS 2
AV703 VIDEO FLOWS
AV704 LIGHTING FLOWS
9 ER1.1
14 PP1.1
(2) 1-1
/2" C
(2 )1
-1 /4
"C
14 PP1.2
(2)1-1/2"C (2)1-1/4"C
(2) 1-1
/2" C
(2)1-1/4"C
1 ST1.5
1 ST1.6
1 ST1.7
1 ST1.8
1 ST1.1
1/2"C
1 ST1.2
1/2"C
1 ST1.3
1/2"C
1 ST1.4
1/2"C
1/2 "C
1/2 "C
1/2 "C
1/2 "C
8 SP4.1 8 SP4.2 8 SP4.3 8 SP4.4
8 SP4.5 8 SP4.6 8 SP4.7 8 SP4.8
14 PP2.1
1 L1.1
PB
1 IF1.1
1"C 1"C
1"C
REVISION
DRAWING NO.
TITLE
PROJECT NUMBER
CHECKED BY
DRAWN BY
DESIGNED BY
DATE
ISSUE
54321 6
A
B
C
D
E
This document contains copyrighted material and information belonging to Stage Front Presentation Systems. Any unauthorized use, disclosure, or duplication of any of the information contained herein may result in liability under applicable laws.
6 SOUTHERN OAKS DR.
SAVANNAH, GA. 31405
PH. 912-236-1345
FAX 912-233-5350
www.sfps.net
AS
AL
AD
04/22/24
K A
R R
H
C O
M M
U N
IT
Y
C
EN
TE
R
D
ES
IG
N
SW
A
IN
SB
O R
O , G
A
AV101
THEATER FLOOR PLAN
DESIGN04/22/24
ADDENDUM 105/28/24
THEATER FLOOR PLANSCALE: 3/16"=1'
THEATER FLOOR PLAN
AV101
SHEET KEY NOTES
1. (QTY. OF 3) 3" CONDUITS CURRENTLY ROUTED FROM
THE CONTROL BOOTH TO STAGE SHOWN FOR
REFERENCE ONLY. CONDUIT PATHS AND TERMINATION
POINTS TBD.
2. CONDUIT TERMINATION POINTS UNDER STAGE SHOWN
FOR REFERENCE ONLY. NOT TO SCALE.
3. (QTY. OF 4) 20A 120VAC CIRCUITS ON (4) QUAD
RECEPTACLES MOUNTED ON WALL 48" A.F.F. IN BACK
PLANE OF EQUIPMENT RACK BY E.C. CONDUITS
STUBBED UP TO ACCESSIBLE CEILING OVER STAGE
AND SEATING AREA AND DOWN TO CONDUIT
TERMINATION LOCATION UNDER THE STAGE.
4. STAGE PRODUCTION PANEL - REQUIRES 10" X 10" BACK
BOX RECESSED IN WALL 18" TO BOTTOM A.F.F.
CONDUITS STUBBED UP TO ACCESSIBLE CEILING OVER
SEATING AREA AND DOWN TO CONDUIT TERMINATION
LOCATION UNDER THE STAGE.
5. QSC SR-1000 WALL MOUNTED SURROUND SOUND
SPEAKERS - REQUIRES 1-GANG BACK BOX MOUNTED
FLUSH IN WALL 7' A.F.F. CONDUITS STUBBED UP TO
ACCESSIBLE CEILING OVER SEATING AREA.
XX
10 SC1.1
01 PR1.11/2"C
1/2"C
8 SP3.1
8 SP1.1
8 SP2.1
8 SP3.2
8 SP1.2
8 SP2.2
REVISION
DRAWING NO.
TITLE
PROJECT NUMBER
CHECKED BY
DRAWN BY
DESIGNED BY
DATE
ISSUE
54321 6
A
B
C
D
E
This document contains copyrighted material and information belonging to Stage Front Presentation Systems. Any unauthorized use, disclosure, or duplication of any of the information contained herein may result in liability under applicable laws.
6 SOUTHERN OAKS DR.
SAVANNAH, GA. 31405
PH. 912-236-1345
FAX 912-233-5350
www.sfps.net
AS
AL
AD
04/22/24
K A
R R
H
C O
M M
U N
IT
Y
C
EN
TE
R
D
ES
IG
N
SW
A
IN
SB
O R
O , G
A
AV201
THEATER AV RCP
DESIGN04/22/24
ADDENDUM 105/28/24
THEATER AV RCPSCALE: 3/16"=1'
THEATER AV RCP
AV201
SHEET KEY NOTES
1. (QTY. OF 1) 20A 120VAC CIRCUIT ON (1) DUPLEX
RECEPTACLE MOUNTED ON WALL 12' A.F.F. BY E.C.
CONDUIT STUBBED UP TO ACCESSIBLE CEILING OVER
STAGE.
2. MOTORIZED PROJECTION SCREEN - REQUIRES 10A
120VAC FEED TO LEFT SIDE OF SCREEN CASING BY E.C.
CONDUIT STUBBED UP TO ACCESSIBLE CEILING OVER
STAGE.
3. P1001 1-5/8'' X 3-1/4'' DOUBLE CHANNEL, 12 GAUGE
UNISTRUT OR EQUIVALENT MOUNTED TO ROOF
STRUCTURE TO SUPPORT SPEAKERS BY STRUCTURAL
CONTRACTOR. REQUIRES CABLE PATH TO EQUIPMENT
RACK ER1.1 BY E.C. UNISTRUT ATTACHMENT TO
STRUCTURE TBD.
1 1 1 1
L5 L5 L5 L5
1 D1.11 D1.21 D1.31 D1.4
REVISION
DRAWING NO.
TITLE
PROJECT NUMBER
CHECKED BY
DRAWN BY
DESIGNED BY
DATE
ISSUE
54321 6
A
B
C
D
E
This document contains copyrighted material and information belonging to Stage Front Presentation Systems. Any unauthorized use, disclosure, or duplication of any of the information contained herein may result in liability under applicable laws.
6 SOUTHERN OAKS DR.
SAVANNAH, GA. 31405
PH. 912-236-1345
FAX 912-233-5350
www.sfps.net
AS
AL
AD
04/22/24
K A
R R
H
C O
M M
U N
IT
Y
C
EN
TE
R
D
ES
IG
N
SW
A
IN
SB
O R
O , G
A
AV202
THEATER LIGHTING RCP
DESIGN04/22/24
ADDENDUM 105/28/24
THEATER LIGHTING RCPSCALE: NONE
THEATER LIGHTING RCP
AV202
SHEET KEY NOTES
1. (QTY. OF 1) 20A 120VAC CIRCUIT ON (1) L5-20 TWIST
LOCK RECEPTACLE MOUNTED ON CEILING BY E.C.
11 3
12'
10' 13'
13'
22'
1' 2'-1"
4'-1" 7'-10" 8'-4"
9'-4" 12'-3"
12'-8" 14'
17'-4" 18'-2"
17'-5"
7'
12'
REVISION
DRAWING NO.
TITLE
PROJECT NUMBER
CHECKED BY
DRAWN BY
DESIGNED BY
DATE
ISSUE
54321 6
A
B
C
D
E
This document contains copyrighted material and information belonging to Stage Front Presentation Systems. Any unauthorized use, disclosure, or duplication of any of the information contained herein may result in liability under applicable laws.
6 SOUTHERN OAKS DR.
SAVANNAH, GA. 31405
PH. 912-236-1345
FAX 912-233-5350
www.sfps.net
AS
AL
AD
04/22/24
K A
R R
H
C O
M M
U N
IT
Y
C
EN
TE
R
D
ES
IG
N
SW
A
IN
SB
O R
O , G
A
AV301
THEATER SECTION
DESIGN04/22/24
ADDENDUM 105/28/24
THEATER SECTIONSCALE: 1/4"=1'
THEATER SECTION
AV301
SHEET KEY NOTES
1. FOH ELECTRIC: DEAD HUNG 30' PIPE BATTEN
2. GRAND VALANCE: 1 PANEL - 4'H X 32'W
3. GRAND DRAPE: 2 PANELS - 16'H X 17'W CURTAINS ON
BI-PARTING TRACK.
4. OVER STAGE 1ST ELECTRIC: DEAD HUNG 30' PIPE
BATTEN.
5. 226" DIAGONAL MOTORIZED REAR PROJECTION
SCREEN. REQUIRES BLACK CASE AND 4 FT. OF BLACK
DROP.
6. BORDER CURTAIN: 1 PANEL - 4'H X 32'W
7. MID-STAGE TRAVELER: 2 PANELS - 16'H X 17'W
CURTAINS ON BI-PARTING TRACK.
8. LEG CURTAINS: 2 PANELS - 16'H X 6'W ON DEAD HUNG
CURTAIN TRACK.
9. OVER STAGE 2ND ELECTRIC: DEAD HUNG 30' PIPE
BATTEN.
10. OVER STAGE 3RD ELECTRIC: DEAD HUNG 30' PIPE
BATTEN.
11. REAR TRAVELER: 2 PANELS - 16'H X 17'W CURTAINS ON
BI-PARTING TRACK.
12. CYCLORAMA: 1 PANEL - 16'H X 32'W ON WALK ALONG
CURTAIN TRACK.
13. BARCO SP2K-11 11K LUMEN PROJECTOR WITH BARCO
ALCHEMY ICMP MEDIA SERVER CARD AND SLENS
1.20-1.70 LENS. THROW DISTANCE RANGE: 16' 5" - 19'"
14. QSC SR-1000 WALL MOUNTED SURROUND SOUND
SPEAKERS - REQUIRES 1-GANG BACK BOX MOUNTED
FLUSH IN WALL 7' A.F.F. CONDUITS STUBBED UP TO
ACCESSIBLE CEILING OVER SEATING AREA.
15. MAIN SPEAKER - QSC PL-DC12 SPEAKER SUSPENDED
FROM CEILING STRUCTURE.
16. SUBWOOFER - QSC PL-SUB 18 SUBWOOFER
SUSPENDED FROM CEILING STRUCTURE.
17. BALCONY FILL SPEAKER - QSC PL-DC24 BALCONY FILL
SPEAKER SUSPENDED FROM CEILING STRUCTURE.
10"
10"
14 PP1.1
STAGE LEFT PRODUCTION PANEL
8" X 8" X 4" SCREW COVER BOX FLUSH ON WALL 18" A.F.F.
BACKBOX PROVIDED AND INSTALLED BY E.C.
FACEPLATE PROVIDED AND INSTALLED BY P.S.C.
10"
10"
14 PP1.2
STAGE RIGHT PRODUCTION PANEL
8" X 8" X 4" SCREW COVER BOX FLUSH ON WALL 18" A.F.F.
BACKBOX PROVIDED AND INSTALLED BY E.C.
FACEPLATE PROVIDED AND INSTALLED BY P.S.C.
14 PP2.1
CONTROL BOOTH PRODUCTION PANEL
2-GANG BACK BOX FLUSH ON WALL 18" A.F.F.
BACKBOX PROVIDED AND INSTALLED BY E.C.
FACEPLATE PROVIDED AND INSTALLED BY P.S.C.
1 IF1.1
CONTROL BOOTH VIDEO INTERFACE PLATE
1-GANG BACK BOX FLUSH ON WALL 18" A.F.F.
BACKBOX PROVIDED AND INSTALLED BY E.C.
FACEPLATE PROVIDED AND INSTALLED BY P.S.C.
MIC A
MIC 1 MIC 2
MIC 4 MIC 5
MIC 7 MIC 8
MIC 10 MIC 11
CONTROL
NET
AUDIO
CONSOLE
MIC 3
MIC 6
MIC 9
MIC 12
MIC A
MON A
MON B
MON A
MON B
REVISION
DRAWING NO.
TITLE
PROJECT NUMBER
CHECKED BY
DRAWN BY
DESIGNED BY
DATE
ISSUE
54321 6
A
B
C
D
E
This document contains copyrighted material and information belonging to Stage Front Presentation Systems. Any unauthorized use, disclosure, or duplication of any of the information contained herein may result in liability under applicable laws.
6 SOUTHERN OAKS DR.
SAVANNAH, GA. 31405
PH. 912-236-1345
FAX 912-233-5350
www.sfps.net
AS
AL
AD
04/22/24
K A
R R
H
C O
M M
U N
IT
Y
C
EN
TE
R
D
ES
IG
N
SW
A
IN
SB
O R
O , G
A
AV401
PLATE DETAILS
DESIGN04/22/24
ADDENDUM 105/28/24
PLATE DETAILS
SCALE: 6" = 1'
PRODUCTION PANEL
AV401
SCALE: 6" = 1'
PRODUCTION PANEL
AV401
SCALE: 6" = 1'
PRODUCTION PANEL
AV401
SCALE: 6" = 1'
VIDEO INTERFACE PLATE
AV401
THREADED ROD
TO STRUCTURE ABOVE
SPEAKER WIRE TO 1-GANG
BACK BOX (BY E.C.) ABOVE
ON RIGGING STRUCTURE.
DRESS WIRE UP THREADED ROD.
FRONT VIEW SIDE VIEW
THREADED ROD
TO STRUCTURE ABOVE
FRONT VIEW SIDE VIEW
SPEAKER
WIREAIRCRAFT
CABLESUBWOOFER
FRONT VIEW SIDE VIEW
THREADED ROD
TO STRUCTURE ABOVE
SPEAKER WIRE TO 1-GANG
BACK BOX (BY E.C.) ABOVE
ON RIGGING STRUCTURE.
DRESS WIRE UP THREADED ROD.
THREADED ROD
TO STRUCTURE ABOVE
QSC PL-DC12 SPEAKER
QSC PL-DC12-YM
YOKE MOUNT
QSC PL-DC24 SPEAKER
QSC PL-DC24-YM
YOKE MOUNT
QSC PL-SUB 18
SUBWOOFER
RIGGING TO STRUCTURE ABOVE
THRU8 SP1.1 8 SP1.2
THRU8 SP2.1 8 SP2.2
THRU8 SP3.1 8 SP3.2
THRU8 SP4.1 8 SP4.8
QSC SR-1000 WALL MOUNTED SURROUND SPEAKER DETAIL
1-GANG BACK BOX MOUNTED FLUSH IN WALL 7' A.F.F. BY E.C.
REQUIRES QSC QM-SW 15° WALL BRACKET
SPEAKER PROVIDED & INSTALLED BY P.S.C.
REVISION
DRAWING NO.
TITLE
PROJECT NUMBER
CHECKED BY
DRAWN BY
DESIGNED BY
DATE
ISSUE
54321 6
A
B
C
D
E
This document contains copyrighted material and information belonging to Stage Front Presentation Systems. Any unauthorized use, disclosure, or duplication of any of the information contained herein may result in liability under applicable laws.
6 SOUTHERN OAKS DR.
SAVANNAH, GA. 31405
PH. 912-236-1345
FAX 912-233-5350
www.sfps.net
AS
AL
AD
04/22/24
K A
R R
H
C O
M M
U N
IT
Y
C
EN
TE
R
D
ES
IG
N
SW
A
IN
SB
O R
O , G
A
AV402
AUDIO DETAILS
DESIGN04/22/24
ADDENDUM 105/28/24
AUDIO DETAILS
SCALE: 1-1/2" = 1'
MAIN SPEAKER DETAIL
AV402
SCALE: 1-1/2" = 1'
BALCONY FILL SPEAKER DETAIL
AV402
SCALE: 1-1/2" = 1'
SUBWOOFER DETAIL
AV402
SCALE: 1" = 1'
WALL MOUNTED SURROUND SPEAKER DETAIL
AV402
WALL MOUNT ARM
PROJECTOR
MOUNT
BARCO SP2K-11
CINEMA PROJECTOR
WITH INTEGRATED
MEDIA SERVER
AND S-LENS
1.20-1.70 LENS
2-GANG BACKBOX
RECESSED FLUSH
ON WALL 12' A.F.F.
BY E.C.
WALL
10 SC1.1
DRAPER PARAGON V AUDITORIUM PROJECTION SCREEN
226" DIAGONAL MOTOTRIZED REAR PROJECTION SCREEN SUSPENDED FROM CEILING STRUCTURE
PROJECTION SCREEN PROVIDED AND INSTALLED BY P.S.C.
LOW VOLTAGE CONTROLLER MOUNTED IN SCREEN HOUSING. REQUIRES 20A 120VAC FEED BY E.C.
REQUIRES BLACK CASE AND 4' OF TOTAL BLACK DROP AT TOP OF PROJECTION SCREEN
120"
Viewable
192"
Viewable
226"
4'
REVISION
DRAWING NO.
TITLE
PROJECT NUMBER
CHECKED BY
DRAWN BY
DESIGNED BY
DATE
ISSUE
54321 6
A
B
C
D
E
This document contains copyrighted material and information belonging to Stage Front Presentation Systems. Any unauthorized use, disclosure, or duplication of any of the information contained herein may result in liability under applicable laws.
6 SOUTHERN OAKS DR.
SAVANNAH, GA. 31405
PH. 912-236-1345
FAX 912-233-5350
www.sfps.net
AS
AL
AD
04/22/24
K A
R R
H
C O
M M
U N
IT
Y
C
EN
TE
R
D
ES
IG
N
SW
A
IN
SB
O R
O , G
A
AV403
VIDEO DETAILS
DESIGN04/22/24
ADDENDUM 105/28/24
VIDEO DETAILS
SCALE: 3/4" = 1'
THEATER PROJECTION SCREEN DETAIL
AV403
SCALE: 2" = 1'
THEATER PROJECTOR DETAIL
AV403
9 ER1.1
STAGE MANAGER'S EQUIPMENT RACK
RACK MOUNTED TO WALL. CONDUIT DIRECTLY TO RACK
EQUIPMENT RACK PROVIDED BY P.S.C. AND INSTALLED BY E.C.
EQUIPMENT PROVIDED AND INSTALLED BY P.S.C.
REQUIRES (4) 20A 120VAC QUAD RECEPTACLES IN BACK PLANE BY E.C.
REQUIRES 5A 120VAC CIRCUIT IN BACK PLANE OF RACK FROM BRANCH PANEL BY E.C.
LAND CONDUIT DIRECTLY
TO EQUIPMENT RACK
" T
O P
O W
ER
O
U
TL
ET
S
(QTY. OF 4) 20A 120VAC CIRCUITS
ON (4) QUAD RECEPTACLES WITH
ISOLATED GROUND WALL MOUNTED
IN BACK PLANE OF EQUIPMENT
RACK BY E.C.
DIGITAL STAGE BOX MOUNTED
ON REAR RAILS OF RACK
CONTROL NETWORK SWITCH MOUNTED
ON REAR RAILS OF RACK
WIRELESS MICROPHONE ANTENNAS
AND AMPLIFIERS MOUNTED TO SIDE OF RACK
LOGO
LISTEN LS-55-072 ALS
BLANK
QSC CORE 110F DSP
HOLLYLAND WL IC TX
SHURE SLXD WRLS 1-2
EXTRON IN1608xi
VIDEO RACK PLATE RP1.1
PATHWAY DMX SPLITTER
BLANK
ALLEN & HEATH AB168
STAGE BOX
BLANK
QSC TSC-70-G3
TOUCH PANEL RP2.1
SHURE SLXD WRLS 3-4
SHURE SLXD MIC A
SHURE UA844 ANT. DIS.
BLANK
BLANK
BLANK
BLANK
TASCAM CD-400U
BLANK
TASCAM BD-MP1
BLANK
LOWELL RPC-4
BLANK
(QTY. OF 3) LOWELL RPC-1 REMOTE
POWER RELAYS MOUNTED
ON REAR RAILS OF RACK
AMPLIFIER 1
AMPLIFIER 2
AMPLIFIER 3
BLANK
BLANK
TRIPPLITE
SMART1500RM2U UPS
BLANK
BLANK
HDMI IN
REVISION
DRAWING NO.
TITLE
PROJECT NUMBER
CHECKED BY
DRAWN BY
DESIGNED BY
DATE
ISSUE
54321 6
A
B
C
D
E
This document contains copyrighted material and information belonging to Stage Front Presentation Systems. Any unauthorized use, disclosure, or duplication of any of the information contained herein may result in liability under applicable laws.
6 SOUTHERN OAKS DR.
SAVANNAH, GA. 31405
PH. 912-236-1345
FAX 912-233-5350
www.sfps.net
AS
AL
AD
04/22/24
K A
R R
H
C O
M M
U N
IT
Y
C
EN
TE
R
D
ES
IG
N
SW
A
IN
SB
O R
O , G
A
AV404
EQUIPMENT RACK DETAILS
DESIGN04/22/24
ADDENDUM 105/28/24
EQUIPMENT RACK DETAILS
SCALE: 1-1/2" = 1'
STAGE MANAGER'S EQUIPMENT RACK
AV404
SCALE: 6" = 1'
VIDEO INTERFACE RACK PLATE RP1.1
AV404
SCALE: 6" = 1'
TOUCH PANEL RACK PLATE RP2.1
AV404
POWER
DMX
RELAY
DMX
DMX OUT
FACEPLATE PROVIDED AND INSTALLED BY P.S.C.
BACKBOX PROVIDED AND INSTALLED BY E.C.
1-GANG BACKBOX PIPE MOUNTED TO LIGHTING BATTEN
THEATER DMX OUTPUT PLATE
D1.11
FACEPLATE PROVIDED AND INSTALLED BY P.S.C.
BACKBOX PROVIDED AND INSTALLED BY E.C.
2-GANG BACKBOX WALL MOUNTED 18" A.F.F.
LIGHTING CONSOLE INPUT PLATE
L1.11 THRU 1 D1.8
DMX IN
REVISION
DRAWING NO.
TITLE
PROJECT NUMBER
CHECKED BY
DRAWN BY
DESIGNED BY
DATE
ISSUE
54321 6
A
B
C
D
E
This document contains copyrighted material and information belonging to Stage Front Presentation Systems. Any unauthorized use, disclosure, or duplication of any of the information contained herein may result in liability under applicable laws.
6 SOUTHERN OAKS DR.
SAVANNAH, GA. 31405
PH. 912-236-1345
FAX 912-233-5350
www.sfps.net
AS
AL
AD
04/22/24
K A
R R
H
C O
M M
U N
IT
Y
C
EN
TE
R
D
ES
IG
N
SW
A
IN
SB
O R
O , G
A
AV405
LIGHTING DETAILS
DESIGN04/22/24
ADDENDUM 105/28/24
LIGHTING DETAILS
SCALE: 3" = 1'
LED PAR FIXTURE
AV405
SCALE: 3" = 1'
LED ELLIPSOIDAL FIXTURE
AV405
SCALE: 6" = 1'
LIGHTING CONSOLE INPUT PLATE
AV405
SCALE: 3" = 1'
DMX RELAY
AV405
SCALE: 3" = 1'
COLOR CHANGING CYC FIXTURE
AV405
SCALE: 6" = 1'
THEATER DMX OUTPUT PLATE
AV405
DMX CABLE TO BOX
ABOVE ON CEILING
STRUCTURE
30'
DMX RELAY
RIGGING HARDWARE
TO STRUCTURE ABOVE
DMX & POWER
EXTENSION CABLES
DRESSED AROUND
PIPE BATTEN
POWER CABLE TO
L5-20 TWISTLOCK
RECEPTACLE (BY E.C.)
DMX CABLE TO BOX
ABOVE ON CEILING
STRUCTURE
DMX RELAY
POWER CABLE TO
L5-20 TWISTLOCK
RECEPTACLE (BY E.C.)
DMX CABLE TO BOX
ABOVE ON CEILING
STRUCTURE
DMX RELAY
POWER CABLE TO
L5-20 TWISTLOCK
RECEPTACLE (BY E.C.)
DMX CABLE TO BOX
ABOVE ON CEILING
STRUCTURE
DMX RELAY
POWER CABLE TO
L5-20 TWISTLOCK
RECEPTACLE (BY E.C.)
30'
30'
30'
RIGGING HARDWARE
TO STRUCTURE ABOVE
DMX & POWER
EXTENSION CABLES
DRESSED AROUND
PIPE BATTEN
RIGGING HARDWARE
TO STRUCTURE ABOVE
DMX & POWER
EXTENSION CABLES
DRESSED AROUND
PIPE BATTEN
(QTY. OF 10) CHAUVET
OVATION CYC 1 FC
(QTY. OF 10) CHAUVET
COLORADO QUAD 1 ZOOM
(QTY. OF 10) CHAUVET
OVATION E910 FC ELLIPSOIDAL
(QTY. OF 10) CHAUVET
COLORADO QUAD 1 ZOOM
RIGGING HARDWARE
TO STRUCTURE ABOVE
DMX & POWER
EXTENSION CABLES
DRESSED AROUND
PIPE BATTEN
REVISION
DRAWING NO.
TITLE
PROJECT NUMBER
CHECKED BY
DRAWN BY
DESIGNED BY
DATE
ISSUE
54321 6
A
B
C
D
E
This document contains copyrighted material and information belonging to Stage Front Presentation Systems. Any unauthorized use, disclosure, or duplication of any of the information contained herein may result in liability under applicable laws.
6 SOUTHERN OAKS DR.
SAVANNAH, GA. 31405
PH. 912-236-1345
FAX 912-233-5350
www.sfps.net
AS
AL
AD
04/22/24
K A
R R
H
C O
M M
U N
IT
Y
C
EN
TE
R
D
ES
IG
N
SW
A
IN
SB
O R
O , G
A
AV406
LIGHTING BATTEN DETAILS
DESIGN04/22/24
ADDENDUM 105/28/24
LIGHTING BATTEN DETAILS
SCALE: 1/2" = 1'
3RD ELECTRIC LIGHTING BATTEN
AV406
SCALE: 1/2" = 1'
2ND ELECTRIC LIGHTING BATTEN
AV406
SCALE: 1/2" = 1'
1ST ELECTRIC LIGHTING BATTEN
AV406
SCALE: 1/2" = 1'
FRONT OF HOUSE LIGHTING BATTEN
AV406
REVISION
DRAWING NO.
TITLE
PROJECT NUMBER
CHECKED BY
DRAWN BY
DESIGNED BY
DATE
ISSUE
54321 6
A
B
C
D
E
This document contains copyrighted material and information belonging to Stage Front Presentation Systems. Any unauthorized use, disclosure, or duplication of any of the information contained herein may result in liability under applicable laws.
6 SOUTHERN OAKS DR.
SAVANNAH, GA. 31405
PH. 912-236-1345
FAX 912-233-5350
www.sfps.net
AS
AL
AD
04/22/24
K A
R R
H
C O
M M
U N
IT
Y
C
EN
TE
R
D
ES
IG
N
SW
A
IN
SB
O R
O , G
A
AV701
AUDIO FLOWS 1
DESIGN04/22/24
ADDENDUM 105/28/24
AUDIO FLOWS 1
TITLE
PROJECT NUMBER
CHECKED BY
DRAWN BY
DESIGNED BY
DATE
ISSUE
54321 6
A
B
C
D
E
This document contains copyrighted material and information belonging to Stage Front Presentation Systems. Any unauthorized use, disclosure, or duplication of any of the information contained herein may result in liability under applicable laws.
6 SOUTHERN OAKS DR.
SAVANNAH, GA. 31405
PH. 912-236-1345
FAX 912-233-5350
www.sfps.net
AS
AL
AD
04/22/24
K A
R R
H
C O
M M
U N
IT
Y
C
EN
TE
R
D
ES
IG
N
SW
A
IN
SB
O R
O , G
A
AV702
AUDIO FLOWS 2
DESIGN04/22/24
ADDENDUM 105/28/24
AUDIO FLOWS 2
TITLE
PROJECT NUMBER
CHECKED BY
DRAWN BY
DESIGNED BY
DATE
ISSUE
54321 6
A
B
C
D
E
This document contains copyrighted material and information belonging to Stage Front Presentation Systems. Any unauthorized use, disclosure, or duplication of any of the information contained herein may result in liability under applicable laws.
6 SOUTHERN OAKS DR.
SAVANNAH, GA. 31405
PH. 912-236-1345
FAX 912-233-5350
www.sfps.net
AS
AL
AD
04/22/24
K A
R R
H
C O
M M
U N
IT
Y
C
EN
TE
R
D
ES
IG
N
SW
A
IN
SB
O R
O , G
A
AV703
VIDEO FLOWS
DESIGN04/22/24
ADDENDUM 105/28/24
VIDEO FLOWS
TITLE
PROJECT NUMBER
CHECKED BY
DRAWN BY
DESIGNED BY
DATE
ISSUE
54321 6
A
B
C
D
E
This document contains copyrighted material and information belonging to Stage Front Presentation Systems. Any unauthorized use, disclosure, or duplication of any of the information contained herein may result in liability under applicable laws.
6 SOUTHERN OAKS DR.
SAVANNAH, GA. 31405
PH. 912-236-1345
FAX 912-233-5350
www.sfps.net
AS
AL
AD
04/22/24
K A
R R
H
C O
M M
U N
IT
Y
C
EN
TE
R
D
ES
IG
N
SW
A
IN
SB
O R
O , G
A
AV704
LIGHTING FLOWS
DESIGN04/22/24
ADDENDUM 105/28/24
LIGHTING FLOWS
| Sheets and Views |
| AV001 LEGEND |
| AV101 THEATER FLOOR PLAN |
| 1 PLAN(2) |
| AV201 THEATER AV RCP |
| 1 PLAN(2) |
| AV202 THEATER LIGHTING RCP |
| 1 PLAN(2) |
| AV301 THEATER SECTION |
| 1 PLAN(2) |
| AV401 PLATE DETAILS |
| DETAIL 1(2) |
| AV402 AUDIO DETAILS |
| DETAIL 1(2) |
| AV403 VIDEO DETAILS |
| DETAIL 1(2) |
| AV404 EQUIPMENT RACK DETAILS |
| DETAIL 1(2) |
| AV405 LIGHTING DETAILS |
| DETAIL 1(2) |
| AV406 LIGHTING BATTEN DETAILS |
| DETAIL 1(2) |
| AV701 AUDIO FLOWS 1 |
| AV702 AUDIO FLOWS 2 |
| AV703 VIDEO FLOWS |
| AV704 LIGHTING FLOWS |
File details come from the government source that posted it. Updated .