Statement of Work (SOW) for 860th AMXS Travis AFB, CA
JLG high reach work platform repair
860th AMXS has a requirement for one high reach JLG work platform repair for C-17 inspections that are required for global contingency missions. For one time repair for JLG high reach work platform
Make Model of JLG: JLG 740AJ/Serial Number 300079874
Description: Contractor shall perform the following repairs/maintenance of equipment:
1) Reseal tower boom cylinder and valve body, and replace bushings on cylinder
2) Reseal jib cylinder
3) Reseal right rear drive motor
4) Replace decals housing and cover on ground control panel and platform control panel
5) Replace platform pivot motor
6) Change engine oil/filter and replace hose guide on boom.
Contractor is not authorized to perform repairs/maintenance on Travis AFB.
Contractor shall have repair completed within 75 days after contract award.
This will be a onetime repair. JLG will be transported back to Hangar 837 Ragsdale Street, Travis AFB, CA, 94535. Contractor shall be responsible for any damage to the equipment being transported.
The JLG shall be repaired and inspected to fulfill the annual inspection by OSHA standards.
Qualifications/Certifications: Technicians performing work on the JLG must possess a license/certification from OSHA.