Jefferson Pipe RFx Specs.pdf

PDF 69 KB Posted

Attached to
Jefferson Slip Liner Pipe
Solicitation number
6100053376
Issued by
Indiana County, Brodheadsville CDP, Pennsylvania

About this file

This document is a Request for Bid (RFB) for a slip liner project issued by Jefferson County PennDOT. The project requires 60 feet of 48-inch plastic slip lining pipe with an inside diameter of approximately 45 inches. The pipe must have a smooth interior and exterior to aid in sliding through an existing bridge structure with a 48-inch opening. The pipe sections cannot exceed 24 feet in length. The bid will be awarded to the lowest bidder per the Reciprocal Limitation Act Requirements (GSPUR-89), which must be completed and attached with the bid submission.

The bid should include the cost of the pipe and any related delivery costs to the Brookville stockpile location. All quantities are estimated. The document does not provide any information about response dates, due dates, site visits, bidder's meetings, award dates, or contract term and renewal options.

View the file

Other files

File Type Posted
GSPUR-89 - Reciprocal Limitations Act Requirements.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Jefferson County PennDOT Slip liner project

Jefferson County PennDOT 10-5 Brookville Stockpile (5926 Route 322, Brookville, PA 15825) is in need of

60 feet of 48” plastic slip lining pipe. The pipe must not exceed an outside diameter of 48 inches and have an inside diameter of approximately 45 inches. The pipe needs to have a smooth interior bore as well as a smooth exterior to aid in sliding through an existing structure. The sections of pipe can be of any length but must not exceed 24 feet for constructability reasons.

The existing bridge structure has an opening of 48 inches and once the pipe is installed, the voids around the pipe will be back filled with concrete grout. The joints should seal together tightly enough to keep the grout from flowing into the pipe.

The bid will be awarded to the lowest bid for 60 feet of the above-mentioned pipe per the guidelines of the Reciprocal Limitation Act Requirements (GSPUR-89). Please complete this form (GSPUR-89) and attach when submitting a bid.

Please submit bid that includes both the cost of the pipe and any related costs i.e. delivery costs to

Brookville stockpile etc.

All quantities are estimated.

File details come from the government source that posted it. Updated .