Medication Dispensing Unit Installation – Construction Documents
This is a 100% Construction Documents package for the Medication Dispensing Unit Installation project, a multi-building effort involving the Department of State Hospitals (DSH) at Patton State Hospital in Patton, California. The project encompasses installation of new medication dispensing units across seven buildings (Buildings 30, 70, EB-235, N-243, U-245, 536, and 512) at the facility located at 3102 East Highland Avenue, Patton, CA 92369. The scope of work includes removal of existing medication dispensing units and floor anchor plates, installation of new floor mounting plates and anchor systems, provision of power and data connections to new equipment locations, patching and painting of existing finishes, and coordination of equipment placement to fit physical space constraints. The equipment to be installed includes ARxIUM MedSelect Flex Cabinet modules in various configurations (drawer modules, supply cabinet modules, tower modules, and compatibility display modules) across 41 medication rooms and related spaces. The drawings are dated September 30, 2025, with State Fire Marshal approval granted on December 16, 2025, and HCAI peer review approved on April 30, 2026. The project has received multiple OSFM permit numbers (25-S-4362 through 25-S-4368) for each building.
The construction documents establish comprehensive requirements for contractor performance, including compliance with the 2022 California Building Standards Code, California Fire Code, California Electrical Code, and applicable NFPA standards. Key technical requirements include investigation and abatement of hazardous materials (asbestos and lead), use of pachometers or ground-penetrating radar to locate existing reinforcing steel before drilling anchor holes, seismic bracing of all equipment per specified standards, and field coordination to adjust equipment locations based on actual space dimensions and rebar placement. The contractor is responsible for all costs associated with field adjustments, patching, painting, and final finishes. The project involves eight OSFM-permitted buildings with varying occupancy classifications (I-2 and I-3) and construction types, with full sprinkler coverage and fire alarm systems required. A minimum 72-hour notice must be provided to the State Fire Marshal for any tests or inspections. The Contract Manager is Ricardo Reilova (559-920-8668), the Construction Administrator is Pang Her (916-508-8283), and the project architect of record is MyoungJin Kang of J.C. Chang & Associates, Inc. located in Torrance, California.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid_Package_P25-00098.pdf | ||
| P25-00098_PROJECT_MANUAL.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
AC.
AC.
AC.
AC.
AC.
AC.
CONC.
CONC.
CONC.
DRIVE
DRIVEDRIVE
CONC.
AC.
AC.
AC.
AC.
STOP 536
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #23790-8
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
DSA STAMP
MEDICATION
DISPENSING UNIT
INSTALLATION
Client Agency
JCCA
385 VAN NESS AVENUE, SUITE 208
ASSOCIATES, INC.
J.C. CHANG &
ARCHITECTS PLANNERSENGINEERS
TORRANCE, CALIFORNIA 90501
PH (310) 212-7644
FAX (310) 212-5272
09/30/2025
DEPARTMENT OF STATE HOSPITALS
100% CONSTRUCTION DOCUMENTS
F
IL
E L \2
-8
M e d ic a ti o n D is p e n s in g U n it I n s ta lla ti o n F iv e H o s p it a ls
D
S H
A D S H
-M D S H
-N D S H
-P D S H
-C C
A D
\D S H
-P a tt o n \2
T .d w g
D A T E /T
IM
E O c t :5
A M
JCCA
DSH
LOCATION PLAN VICINITY MAP SCOPE OF WORK
3102 EAST HIGHLAND AVENUE, PATTON, CALIFORNIA 92369
DEPARTMENT OF STATE HOSPITALS - PATTON
DEPARTMENT OF STATE HOSPITALS
T0.1
1. CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER 33 - FIRE SAFETY
DURING CONSTRUCTION OF THE 2022 CALIFORNIA FIRE CODE.
FIRE SAFETY DURING CONSTRUCTION
1. REMOVE (E) MEDICATION DISPENSING UNITS AND STORE PER THE OWNER’S INSTRUCTIONS.
2. REMOVE FLOOR ANCHOR PLATES IN EACH NURSE/MED ROOM AS REQUIRED.
3. PROVIDE POWER & DATA TO (N) EQUIPMENT LOCATIONS WHERE REQUIRED AND VERIFY
FUNCTIONALITY
4. PATCH & PAINT EXISTING FINISHES AS NEEDED TO MATCH EXISTING.
5. PREPARE AND DETERMINE EACH MOUNTING LOCATION AND INSTALL NEW ANCHOR PLATES TO
PREPARE FOR EQUIPMENT INSTALLATION.
MEDICATION DISPENSING UNIT INSTALLATION
MULTI-BUILDING SUBMITTAL - PRIMARY OSFM PERMIT NUMBER: 25-4362
PROJECT INFORMATION
PREPARED BY:
J.C. CHANG & ASSOCIATES, INC.
ENGINEERS, ARCHITECTS AND PLANNERS
385 VAN NESS AVENUE, SUITE 208
TORRANCE, CALIFORNIA 90501
PHONE : (310) 212-7644
ARCHITECT OF RECORD /
PRIMARY PROFESSIONAL
MYOUNGJIN KANG
NO. C-37614
385 VAN NESS AVE. #208
TORRANCE, CALIFORNIA 90501
1. NO DEFERRED APPROVAL ON THIS PROJECT
DEFERRED APPROVALS APPLICABLE CODES AND STANDARDS
TITLE SHEET
1. 2022 BUILDING STANDARDS ADMINISTRATIVE CODE, PART 1, TITLE 24 C.C.R.
2. 2022 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 C.C.R.
(2021 INTERNATIONAL BUILDING CODE & 2021 CALIFORNIA AMENDMENTS)
3. 2022 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R.
(2020 NATIONAL ELECTRICAL CODE AND 2021 CALIFORNIA AMENDMENTS)
4. 2022 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 C.C.R.
(2021 UNIFORM MECHANICAL CODE AND 2021 CALIFORNIA AMENDMENTS)
5. 2022 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R.
(2021 UNIFORM PLUMBING CODE AND 2021 CALIFORNIA AMENDMENTS)
6. 2022 CALIFORNIA ENERGY CODE (CEC), PART 6, TITLE 24 C.C.R.
7. 2022 CALIFORNIA FIRE CODE, PART 9, TITLE 24 C.C.R.
(2021 INTERNATIONAL FIRE CODE AND 2021 CALIFORNIA AMENDMENTS)
8. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN), PART 11,
TITLE 24 C.C.R.
9. 2022 CALIFORNIA REFERENCED STANDARDS, PART 12, TITLE 24 C.C.R.
10. TITLE 19 C.C.R., PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS.
PARTIAL LIST OF APPLICABLE STANDARDS
1. NFPA 13 AUTOMATIC SPRINKLER SYSTEMS (CA AMENDED) 2022 EDITION
2. NFPA 14 STANDPIPE SYSTEM (CA AMENDED) 2019 EDITION
3. NFPA 17a WET CHEMICAL SYSTEMS 2021 EDITION
4. NFPA 20 STATIONARY PUMPS 2019 EDITION
5. NFPA 24 PRIVATE FIRE MAINS (CA AMENDED) 2019 EDITION
6. NFPA 72 NATIONAL FIRE ALARM CODE (CA AMENDED) 2022 EDITION
7. NFPA 2001 CLEAN AGENT FIRE EXTINGUISHING SYSTEMS 2018 EDITION
W/ CA AMENDMENTS
8. NFPA 101 LIFE SAFETY CODE 2021 EDITION
9. REFERENCE CODE SECTION FOR NFPA STANDARDS 2022 CBC (SFM)
CHAPTER 35
REFERENCE CODE SECTION FOR NFPA STANDARDS ARE IN 2022 CBC CHAPTER 35 OR 2022 CFC
CHAPTER 80. SEE CHAPTER 35 FOR STATE OF CALIFORNIA AMENDMENTS TO NFPA STANDARDS.
REFERENCE: 2022 CALIFORNIA FIRE CODE
1. SEE OVERALL SITE PLAN FOR SITE ACCESS FOR BOTH PUBLIC RIGHT OF WAY AND LOCAL
FIRE DEPARTMENT.
2. TURNAROUND CAN BE ACCOMPLISHED BY USING EXISTING SITE ROADS. SEE T0.2.
FIRE APPARATUS ACCESS
1. THE CONTRACTOR IS RESPONSIBLE FOR INVESTIGATING HAZARDOUS MATERIAL AT THE AREA
OF WORK INCLUDING BUT NOT LIMITED TO ASBESTOS AND LEAD, AND PROVIDING A REPORT
AND ABATEMENT PLAN ACCORDING TO THE CALIFORNIA STANDARD CODE AND CALOSHA
REQUIREMENTS.
HAZMAT NOTE
1. BIDDER'S ATTENTION IS DIRECTED TO THE FACT THAT THE LOCATIONS OF THE MEDICATION
DISPENSING UNITS SHOWN IN THE DRAWINGS IS DIAGRAMMATIC AND SCHEMATIC IN NATURE.
IT IS EXPECTED THAT THE CONTRACTOR WILL MAKE THE NECESSARY FIELD ADJUSTMENTS TO
COORDINATE THE EXACT LOCATION OF THE UNITS TO FIT WITHIN THE PHYSICAL CONSTRAINTS
OF THE SPACES SHOWN.
2. THE BASE BID MUST INCLUDE THE COST ASSOCIATED WITH MAKING FIELD ADJUSTMENTS AS
NEEDED BASED ON THE DIMENSIONS OF THE EQUIPMENT AND MOUNTING PLATE ANCHORAGE
CRITERIA. THE MOUNTING PLATE LOCATIONS WILL REQUIRE COORDINATION IN EACH
LOCATION TO AVOID CUTTING OR DAMAGE TO THE EXISTING REBAR. SEE THE STRUCTURAL
DRAWINGS FOR ADDITIONAL INFORMATION. IT IS EXPECTED THAT THE BIDDER WILL BE A
QUALIFIED CONTRACTOR WITH RECENT, RELEVANT EXPERIENCE WITH PROJECTS OF SIMILAR
SIZE AND SCALE, AND UTILIZE THEIR QUALIFICATIONS AND EXPERIENCE TO PROVIDE A
COMPLETE AND ACCURATE BASE BID.
BASE BID
PROJECT AREA
A MINIMUM OF 72 HOURS NOTICE WILL BE PROVIDED TO THE STATE FIRE MARSHAL WHEN
SCHEDULING ANY TESTS OR INSPECTIONS.
STATE FIRE MARSHAL SPECIAL INSPECTIONS
DRAWING INDEX
GENERAL
T0.1 TITLE SHEET
T0.2 FIRE ACCESS SITE PLAN
T0.3 STATE FIRE MARSHAL TRIAGE LIST
T0.4 BUILDING INFORMATION
ARCHITECTURAL
00-A0.1 ARCHITECTURAL COVER SHEET
00-A0.2 OVERALL SITE PLAN
00-A0.3 ELECTRICAL SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES
00-A3.1 DETAIL SHEET
01-A0.1 BUILDING 30 - FIRST FLOOR OVERALL PLAN
01-A0.2 BUILDING 30 - SECOND FLOOR OVERALL PLAN
01-A1.1 BUILDING 30 - FIRST AND SECOND FLOOR DEMOLITION PLANS
01-A2.1 BUILDING 30 - FIRST AND SECOND FLOOR NEW WORK PLANS
01-A4.1 BUILDING 30 - FIRST FLOOR ELEVATIONS - MED RM - 30-19, 31-19, 32-19, 33-19 -
UNITS 30, 31, 32, 33
01-A4.2 BUILDING 30 - SECOND FLOOR ELEVATIONS - MED RM - 34-19, 31-19, 36-19, 37-19 -
UNITS 34, 35, 36, 37
02-A0.1 BUILDING 70 - FIRST FLOOR OVERALL PLAN
02-A0.2 BUILDING 70 - SECOND FLOOR OVERALL PLAN
02-A1.1 BUILDING 70 - FIRST AND SECOND FLOOR DEMOLITION PLANS
02-A2.1 BUILDING 70 - FIRST AND SECOND FLOOR NEW WORK PLANS
02-A4.1 BUILDING 70 - FIRST FLOOR ELEVATIONS - MED RM - 70-19, 71-19, 72-19, 73-19 -
UNITS 70, 71, 72, 73
02-A4.2 BUILDING 70 - SECOND FLOOR ELEVATIONS - MED RM - 74-19, 75-19, 76-19, 77-19 -
UNITS 74, 75, 76, 77
03-A0.1 EB BUILDING 235 - FIRST FLOOR OVERALL PLAN
03-A0.2 EB BUILDING 235 - SECOND FLOOR OVERALL PLAN
03-A0.3 EB BUILDING 235 - THIRD FLOOR OVERALL PLAN
03-A1.1 EB BUILDING 235 - FIRST FLOOR DEMOLITION PLANS
03-A1.2 EB BUILDING 235 - SECOND AND THIRD FLOOR DEMOLITION PLANS
03-A2.1 EB BUILDING 235 - FIRST FLOOR NEW WORK PLANS
03-A2.2 EB BUILDING 235 - SECOND AND THIRD FLOOR NEW WORK PLANS
03-A4.1 EB BUILDING 235 - FIRST FLOOR ELEVATIONS - MED RM - 10-125, 11-143, 12-101, A111, A196A
UNITS EB 10, 11, 12
03-A4.2 EB BUILDING 235 - SECOND & THIRD FLOOR ELEVATIONS - MED RM - 1-220, 2-204, 9-218, 4-323
UNITS EB 01, 02, 04, 09
04-A0.1 N BUILDING 243 - FIRST FLOOR OVERALL PLAN
04-A0.2 N BUILDING 243 - SECOND FLOOR OVERALL PLAN
04-A1.1 N BUILDING 243 - FIRST AND SECOND FLOOR DEMOLITION PLANS
04-A2.1 N BUILDING 243 - FIRST AND SECOND FLOOR NEW WORK PLANS
04-A4.1 N BUILDING 243 - FIRST FLOOR ELEVATIONS - MED RM - 21-07, 21-10, 23-06, 23-09, C121
UNITS 21, 23, BUILDING CENTRAL CORE
04-A4.2 N BUILDING 243 - FIRST FLOOR ELEVATIONS - MED RM - 25-05, 25-08, 27-06, 27-09 -
UNITS 25, 27
05-A0.1 U BUILDING 245 - OVERALL PLAN
05-A1.1 U BUILDING 245 - DEMOLITION PLANS
05-A2.1 U BUILDING 245 - NEW WORK PLANS
05-A4.1 U BUILDING 245 - ELEVATIONS - MED RM - 05-04, 06-04 - UNITS 05, 06
06-A0.1 BUILDING 536 - OVERALL PLAN
06-A1.1 BUILDING 536 - DEMOLITION PLANS
06-A2.1 BUILDING 536 - NEW WORK PLANS
06-A4.1 BUILDING 536 - ELEVATION - CLASSROOM
07-A0.1 BUILDING 512 - OVERALL PLAN
07-A1.1 BUILDING 512 - DEMOLITION PLAN
07-A2.1 BUILDING 512 - NEW WORK PLANS
07-A4.1 BUILDING 512 - ELEVATION - VISITING ROOM
STRUCTURAL
S0.1 STRUCTURAL NOTES & RESEARCH REPORT EXCERPT
S3.1 STRUCTURAL DETAILS
TOTAL NUMBER OF SHEETS = 49
OSFM PERMIT NUMBERS FOR MULTIPLE BUILDINGS
BUILDING NAME OSFM PERMIT NUMBER
1. BUILDING 30 25-S-4362 (PRIMARY)
2. BUILDING 70 25-S-4363
3. EB BUILDING 235 25-S-4364
4. N BUILDING 243 25-S-4365
5. U BUILDING 245 25-S-4366
6. BUILDING 536 25-S-4367
7. BUILDING 512 25-S-4368
NN
PREPARED FOR:
DEPARTMENT OF STATE HOSPITALS
PATTON (DSH-P)
3102 E. HIGHLAND AVENUE
PATTON, CA 92369
DEPARTMENT OF STATE HOSPITALS (DSH)
1600 9TH STREET, ROOM 120
SACRAMENTO, CA 95814
RICARDO REILOVA
CONTRACT MANAGER
OFFICE: (559) 920-8668
EMAIL: RICARDO.REILOVA@DSH.CA.GOV
PANG HER
CONSTRUCTION ADMINISTRATOR
CELL: (916) 508-8283
EMAIL: PANG.HER@DSH.CA.GOV
KRIS BADKAR
ASSOCIATE CONSTRUCTION ANALYST
DSH-PATTON, FACILITY OPERATIONS
PHONE: 909-742-5481
CELL: 909-522-0627
EMAIL: KRISAN.BADKAR@DSH.CA.GOV
PATTON
STATE
HOSPITAL
210 330
V
IC
T O
R
IA
A V E N U
E
C E N T R
A L A
V E N U
E
P A L M
A V E N U
E
BASE LINE STREET
E HIGHLAND AVENUE
PROJECT LOCATION
V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/16/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-4362
DATE:
APPROVAL OF THIS PLAN DOES NOT
AUTHORIZE OR APPROVE ANY OMISSION OR
DEVIATION FROM APPLICABLE REGULATIONS
REVIEWED BY:
HCAI PEER REVIEWER
04-30-2026
Jeremy Willett. JCCA Thu Oct 16 10:01:08 2025: V1
70 243
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #23790-8
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
DSA STAMP
MEDICATION
DISPENSING UNIT
INSTALLATION
Client Agency
JCCA
385 VAN NESS AVENUE, SUITE 208
ASSOCIATES, INC.
J.C. CHANG &
ARCHITECTS PLANNERSENGINEERS
TORRANCE, CALIFORNIA 90501
PH (310) 212-7644
FAX (310) 212-5272
09/30/2025
DEPARTMENT OF STATE HOSPITALS
100% CONSTRUCTION DOCUMENTS
F
IL
E C
U s e rs
\J E R
E M
Y \A p p D a ta
\L o c a l\ T e m p \A c P u b lis h \2
T .d w g
D A T E /T
IM
E O c t :5
A M
JCCA
DSH
SITE ACCESS FROM PUBLIC
RIGHT OF WAY AND USING
EXISTING PAVED ROADS
LEGEND:
FIRE TRUCK ROUTE
FIRE HYDRANT
WEST SALLY PORT
CENTRAL SALLY PORT
BUILDING NAME
FIRE ACCESS SITE PLAN
SCALE: N 0 24020 FEET120
1" = 120'
T0.2
FIRE ACCESS SITE PLAN
HIGHLAND FIRE DEPARTMENT
30. 30 BUILDING
243. N BUILDING
536. COTTAGE M STAFF
DEVELOPMENT CENTER
70. 70 BUILDING
235. BERNATH BUILDING (EB)
245. U BUILDING
EAST SALLY PORT
(PEDESTRIAN ONLY)
V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/16/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-4362
Jeremy Willett. JCCA Thu Oct 16 10:01:10 2025: V1
STATE FIRE MARSHAL TRIAGE
LIST
T0.3
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #23790-8
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
DSA STAMP
MEDICATION
DISPENSING UNIT
INSTALLATION
Client Agency
JCCA
385 VAN NESS AVENUE, SUITE 208
ASSOCIATES, INC.
J.C. CHANG &
ARCHITECTS PLANNERSENGINEERS
TORRANCE, CALIFORNIA 90501
PH (310) 212-7644
FAX (310) 212-5272
09/30/2025
DEPARTMENT OF STATE HOSPITALS
100% CONSTRUCTION DOCUMENTS
F
IL
E C
U s e rs
\J E R
E M
Y \A p p D a ta
\L o c a l\ T e m p \A c P u b lis h \2
T .d w g
D A T E /T
IM
E O c t :5
A M
JCCA
DSH
ITEM SUBMITTAL REQUIREMENTS SUBMITTAL RESPONSE REFERENCE
GENERAL
SEE FOR SPECIFIC SECTION COMMENTS NOT APPLICABLE
PROVIDE A COMPLETE PLAN REVIEW APPLICATION
SUBMIT PLANS SUFFICIENT SIZE
PROVIDE SITE ADDRESS
PROVIDE NAME OF OWNER AND OCCUPANT
IDENTIFY IF NEW CONSTRUCTION OR T.I
IDENTIFY IF NEW OR EXISTING TENANT SPACE
IDENTIFY IF DEFERRED SUBMITTAL
ADD OSFM FILE NUMBER TO TITLE SHEET
PROJECT IS A PHASED SUBMITTAL
SLIP SHEETS SHALL BE BOUND TO SET
SHEET INDEX
WET STAMP AND SIGN SHEETS
SCOPE OF WORK
PROVIDED WITH SUBMITTAL
FLOOR PLANS ARE 1/8"=1' MINIMUM
3102 HIGHLAND AVE., PATTON, CA 92369
OWNER: DEPARTMENT OF STATE HOSPITALS
T.I.
EXISTING
ALL RELEVANT
SHEETS
NOT APPLICABLE
T0.1
T0.1
OSFM NO #### IS NOTED ON THE TITLE SHEET T0.1
PROJECT IS NOT PHASED
NOT APPLICABLE
SHEET INDEX IS ON T0.1 T0.1
ELECTRONIC SIGNATURE PROVIDED ON DOCUMENT ALL SHEETS
SCOPE OF WORK IS INCLUDED ON TITLE SHEET T0.1
OCCUPANT: DEPARTMENT OF STATE HOSPITALS
V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/16/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
BUILDING INFORMATION
T0.4
BUILDING INFORMATION
BUILDING NAME
CONSTRUCTION
TYPE
NUMBER
OF STORIES
BUILDING
AREA
IN SQ. FT.
SEPARATED /
NON SEPARATED
PARTIAL
SPRINKLER
COVERAGE
FIRE ALARM
OTHER
PROTECTION
SYSTEM
SMOKE
CONTROL
SYSTEM
OCCUPANT
LOAD
YEAR BUILDING
CONSTRUCTED
HIGH FIRE
HAZARD
SEVERITY
ZONE
SEISMIC JOINT
EMERGENCY
RESPONDER RADIO
COVERAGE
OCCUPANCY
GROUP
I-2 / I-3
BUILDING
HEIGHT
AREA OF
PROJECT
ALLOWABLE
STORIES
(CBC TABLE
504.3)
USE
ALLOWABLE
AREA
(CBC TABLE
506.2)
YES NO 960 1960
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #23790-8
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
DSA STAMP
MEDICATION
DISPENSING UNIT
INSTALLATION
Client Agency
JCCA
385 VAN NESS AVENUE, SUITE 208
ASSOCIATES, INC.
J.C. CHANG &
ARCHITECTS PLANNERSENGINEERS
TORRANCE, CALIFORNIA 90501
PH (310) 212-7644
FAX (310) 212-5272
09/30/2025
DEPARTMENT OF STATE HOSPITALS
100% CONSTRUCTION DOCUMENTS
F
IL
E C
U s e rs
\J E R
E M
Y \A p p D a ta
\L o c a l\ T e m p \A c P u b lis h \2
T .d w g
D A T E /T
IM
E O c t :5
A M
JCCA
DSH
YES YES NO YES YES
YES NO 1960YES YES NO YES YES
YES NO 1954YES YES NO YES YES
B NO NO 1913YES NO NO NO YES
YES NO 1951YES YES NO YES YES
YES NO 1956YES YES NO YES YES
1958 UBC TYPE
I-F.R.
3 + BASEMENT
2 + PARTIAL
BASEMENT
22'-0" 112,500 36 S.F.
36 S.F.
36 S.F.
36 S.F.
36 S.F.
36 S.F.
PATIENT
HOUSING
UNLIMITED UNLIMITED SEPARATED
I-2 / I-3
I-2 / I-3
I-2 / I-3
I-2 / I-3
1958 UBC TYPE
I-F.R.
1952 UBC TYPE
I-F.R.
1949 UBC TYPE
I-F.R.
V-B
1952 UBC TYPE
I-F.R.
22'-0"
31'-10"
25'-4"
21'-0"
11''-6 1/2"
112,500
132,000
140,000
8,200
30,000
PATIENT
HOUSING
PATIENT
HOUSING
PATIENT
HOUSING
OFFICES
PATIENT
HOUSING
UNLIMITED
UNLIMITED
UNLIMITED
9,000 S.F.
UNLIMITED
UNLIMITED
UNLIMITED
UNLIMITED
UNLIMITED
SEPARATED
SEPARATED
SEPARATED
NON
SEPARATED
SEPARATED
1,030
30. 30 BUILDING
243. N BUILDING
536. COTTAGE M STAFF
DEVELOPMENT CENTER
70. 70 BUILDING
235. ED BERNATH BUILDING (EB)
245. U BUILDING
B NO NO 1985NO NO NO NO YES1 36 S.F.
1982 UBC TYPE
II-B
14'-7" 2,835 OFFICES 23,000 S.F. 3
NON
SEPARATED
18.9
512. CENTRAL SALLY
PORT/CENTRAL PHARMACY
V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/16/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
00-A0.1
ARCHITECTURAL COVER
SHEET
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #23790-8
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
DSA STAMP
MEDICATION
DISPENSING UNIT
INSTALLATION
Client Agency
JCCA
385 VAN NESS AVENUE, SUITE 208
ASSOCIATES, INC.
J.C. CHANG &
ARCHITECTS PLANNERSENGINEERS
TORRANCE, CALIFORNIA 90501
PH (310) 212-7644
FAX (310) 212-5272
09/30/2025
DEPARTMENT OF STATE HOSPITALS
100% CONSTRUCTION DOCUMENTS
F
IL
E C
U s e rs
\J E R
E M
Y \A p p D a ta
\L o c a l\ T e m p \A c P u b lis h \2
-A
.d w g
D A T E /T
IM
E O c t :5
A M
JCCA
DSH
LIGHT, THIN LINES INDICATE EXISTING.
HEAVY, THICK LINES INDICATE NEW
HEAVY, SHORT DASHED LINES INDICATE
DEMOLITION OR REMOVAL
TYPICAL PLAN LEGEND
THIS SYMBOLOGY TO BE USED BY ARCHITECTURAL AND LAYOUT FOR
ALL FLOOR PLANS, EQUIPMENT, DEVICES, UTILITIES, ETC., SHOWN ON
DRAWINGS.
GENERAL NOTES
(D) DEMOLISH
(E) EXISTING
(N) NEW
@ AT
& AND
ADJ ADJACENT
ALUM ALUMINUM
A.R.F. ANIMAL RESCUE FORCE
ASTM. AMERICAN SOCIETY FOR
TESTING MATERIALS
ARCH. ARCHITECTURAL OR
ARCHITECT
A.C. ASPHALT CONCRETE
AVE. AVENUE
BLDG. BUILDING
CA. CALIFORNIA
C.B. CATCH BASIN
C.H. CEILING HEIGHT
CLG. CEILING
CEM CEMENT
CEM. MORT. CEMENT MORTAR
CLR. CLEAR
CONC. CONCRETE
CONC. BLK CONCRETE BLOCK
CONST. CONSTRUCTION
C.J. CONSTRUCTION JOINT
CORR. CORRIDOR
DET. DETAIL
DIA.Ø DIAMETER
DIM. DIMENSION
D.O. DOOR OPENING
D.F. DOUGLAS FIR
DN. DOWN
D.S. DOWN SPOUT
DWG. DRAWING
EA. EACH
E EAST
ELECT. ELECTRICAL
EL. ELEVATION
ENGR. ENGINEER
EQ. EQUAL
EXIST. EXISTING
EXP. EXPANSION
EXP. JT. EXPANSION JOINT
EXT EXTERIOR
F.O.C. FACE OF CONCRETE
F.O.M. FACE OF MASONRY
FT. FEET
FIN. FINISH
F.F. FINISH FLOOR OR
FACTORY FINISH
F.S. FINISH SURFACE
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER
CABINET
F.H.C. FIRE HOSE CABINET
F.H. FIRE HYDRANT
FLR. FLOOR
F.D. FLOOR DRAIN
GA. GAGE (GAUGE)
GSM GALVANIZED SHEET METAL
GALV. GALVANIZED
GL. GLASS
HGT. / HT. HEIGHT
H.B HOSE BIBB
IN. INCHES
INFO INFORMATION
I.D. INSIDE DIAMETER
JT. JOINT
LT.WT. LIGHT WEIGHT
FF. LINEAL FOOT
MFR. MANUFACTURER
M.O. MASONRY OPENING
MATL. MATERIAL
MAX. MAXIMUM
MECH. MECHANICAL
MTL. METAL
MIN. MINIMUM
MISC. MISCELLANEOUS
N NORTH
N.I.C. NOT IN CONTRACT
N.T.S. NOT ON SALE
NO. / # NUMBER
O.C. or O/C ON CENTER
OCC OCCUPANT/OCCUPANCY
O.D. OUTSIDE DIAMETER
P.A. PLANTING AREA
PLAS. PLASTER
PLYWD. PLYWOOD
PREFAB. PREFABRICATED
PL PROPERTY LINE
POC POINT OF CONTACT
QTY. QUANTITY
REQD. REQUIRED
R.O. ROUGH OPENING
SF SQUARE FOOT
SHT. SHEET
SIM. SIMILAR
S SOUTH
SPEC(S) SPECIFICATION(S)
SQ.FT. SQUARE FOOT/FEET
S. STL. STAINLESS STEEL
STD. STANDARD
STL. STEEL
S.D. STORM DRAIN
ST. STREET
STRUCT. STRUCTURAL
THK. THICK
T&G TONGUE & GROOVE
TYP. TYPICAL
U.L. UNDERWRITERS
LABORATORIES
INCORPORATED
U.B.C. UNIFORM BUILDING
U.N.O. UNLESS NOTED
OTHERWISE
VENT VENTILATION
V.P. VENT PIPE
V.T.R. VENT THROUGH ROOF
VERT. VERTICAL
VOL. VOLUME
W.H. WATER HEATER
W.M. WATER METER
WT. WEIGHT
W WEST
W.D. WINDOW DIMENSION
W.O. WINDOW OPENING
W/ WITH
W/O WITHOUT
WD. WOOD
ABBREVIATIONS SYMBOL LIST
X
X-XX
CENTERLINE DIMENSION
FACE DIMENSION LINE
DETAIL NUMBER
SHEET NUMBER
DETAIL REFERENCE SYMBOL
NEW WORK KEYNOTE
DEMOLITION KEYNOTE
SYMBOL DESCRIPTION
DETAIL NUMBER
SHEET NUMBER
A2.01
EL. DETAIL NUMBER
SHEET NUMBER
A3.01
A3.01
SECTION NUMBER
(BUILDING SECTION)
SHEET NUMBER
A3.01
SECTION NUMBER
(BUILDING SECTION)
SHEET NUMBER
A3.01
DETAIL NUMBER
SHEET NUMBER
INTERIOR EL. SHOWN
WORK POINT
DATUM LINE
MATCH LINE
REVISION CLOUD AND DELTA
DOOR NUMBER
WINDOW NUMBER
C.H. 9'-0"
GRID IDENTIFICATION
ROOM NAME
ROOM NUMBER
ROOM HEIGHT
EQUIPMENT TAG
X X-###
LOBBY
B-23
125 SQ.FT.
SQUARE FOOT/FEET
X
XXX
GENERAL PROJECT CODE NOTES
XX-XX
1. ALL WORK SHALL CONFORM TO THE CONTRACT DOCUMENTS WHICH INCLUDE THE
OWNER/CONTRACTOR AGREEMENT, THE DRAWINGS AND ALL ADDENDA AND MODIFICATIONS
ISSUED BY THE DESIGNER.
2. THE CONTRACTOR SHALL REVIEW ALL DOCUMENTS AND VERIFY ALL DIMENSIONS AND FIELD
CONDITIONS AND SHALL CONFIRM THAT WORK IS BUILDABLE AS SHOWN. ANY CONFLICTS OR
OMISSIONS, ETC., SHALL BE IMMEDIATELY REPORTED TO THE DESIGNER FOR CLARIFICATION
PRIOR TO THE PERFORMANCE OF ANY WORK IN QUESTION.
3. THE CONTRACTOR SHALL OBTAIN ALL PERMITS AND INSPECTIONS AND COMPLY WITH ALL
CODES, LAWS, ORDINANCES, RULES, AND REGULATIONS OF ALL PUBLIC AUTHORITIES
(FEDERAL, STATE, OR LOCAL) GOVERNING THE WORK. THE MOST STRINGENT SHALL APPLY.
4. SUBSTITUTIONS, IF ALLOWED, MUST BE SUBMITTED TO THE DESIGNER FOR REVIEW (IN
CONFORMANCE WITH SPECIFIED PROCEDURES) PRIOR TO PURCHASE, FABRICATION, OR
INSTALLATION. PROPOSED SUBSTITUTIONS SHALL BE CLEARLY IDENTIFIED ON THE COVER
OF THE SUBMITTAL AND SHALL BE ACCOMPANIED WITH A COMPREHENSIVE COMPARATIVE
ANALYSIS OF THE 2 PRODUCTS FOR VERIFICATION OF EQUIVALENCY. IF SUCH A SUBMITTAL
REQUIRES ADDITIONAL REVIEW TIME BEYOND WHAT IS NORMALLY EXPECTED, THE
DESIGNER WILL BE COMPENSATED FOR THE ADDITIONAL TIME SPENT.
5. PROTECT THE BUILDING, ITS SYSTEMS, FINISHES, AND RELATED AND APPURTENANT ITEMS, SO AS NOT TO CAUSE DAMAGE DERIVED FROM THE WORK, COMPLY WITH BUILDING RULES
AND REGULATIONS.
6. "TYPICAL" OR "TYP." SHALL MEAN THAT THE CONDITION IS REPRESENTATIVE FOR SIMILAR
CONDITIONS THROUGHOUT, UNLESS OTHERWISE NOTED. DETAILS ARE USUALLY KEYED AND
NOTED "TYP." ONLY ONCE, WHEN THEY FIRST OCCUR.
7. "SIMILAR" MEANS COMPARABLE CHARACTERISTICS FOR THE CONDITIONS NOTED, VERIFY
DIMENSIONS AND ORIENTATION ON PLANS AND ELEVATIONS.
8. DIMENSIONS ARE NOT ADJUSTABLE WITHOUT WRITTEN APPROVAL FROM THE DESIGNER.
9. THE CONTRACTOR SHALL NOT BE RELIEVED OF RESPONSIBILITY FOR DEVIATIONS FROM
REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE DESIGNER'S REVIEW OF SHOP
DRAWINGS, PRODUCT DATA SAMPLES OR SIMILAR SUBMITTALS UNLESS THE CONTRACTOR
HAS SPECIFICALLY INFORMED THE DESIGNER IN WRITING OF SUCH DEVIATION AT THE TIME
OF SUBMITTAL AND THE DESIGNER HAS REVIEWED THE SPECIFIC DEVIATION FOR
COMPLIANCE WITH THE INTENT OF THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL
NOT BE RELIEVED OF RESPONSIBILITY FOR ERRORS OR OMISSIONS IN SHOP DRAWINGS,
PRODUCT DATA, SAMPLES OR SIMILAR SUBMITTALS BY THE DESIGNER'S REVIEW THEREOF.
10. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE, REQUEST & FORWARD TO
THE DESIGNER FOR REVIEW AND APPROVAL SHOP DRAWINGS, PRODUCT DATA, SAMPLES &
SIMILAR SUBMITTALS REQUIRED BY THE CONTRACT DOCUMENTS IN A TIMELY MANNER IN
ORDER TO ALLOW PROPER REVIEW, APPROVAL, AND LEAD TIME ON ORDERING MATERIALS
AND EQUIPMENT SUCH THAT THERE ARE NO DELAYS TO THE PROJECT SCHEDULE.
INCOMPLETE SUBMITTALS WILL BE RETURNED UN-REVIEWABLE. THE DESIGNER SHALL BE
COMPENSATED FOR ADDITIONAL SERVICES FOR SUBMITTALS REQUIRING MORE THAN 2
REVIEWS DUE TO LACK OF INFORMATION, INCORRECT OR INCOMPLETE INFORMATION.
11. ALL OPEN JOINTS OR GAPS IN THE FINISHES RESULTING FROM THE ALTERATIONS SHALL BE
CAULKED AND SEALED TO PROVIDE SMOOTH CONTINUOUS SURFACES SUFFICIENT TO
RECEIVE TOUCH-UP, SUCH AS PAINT TO MATCH EXISTING AS REQUIRED.
12. ALL MANUFACTURED ARTICLES, MATERIAL AND EQUIPMENT SHALL BE APPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED, AND CONDITIONED AS DIRECTED BY THE
MANUFACTURER UNLESS HEREIN SPECIFIED TO THE CONTRARY. IN CASE OF DIFFERENCE
BETWEEN THE MANUFACTURER'S INSTRUCTION AND THE CONTRACT DOCUMENTS, THE
CONTRACTOR SHALL NOTIFY THE DESIGNER BEFORE PROCEEDING.
13. ALL CONTRACT DOCUMENTS, INCLUDING WITHOUT LIMITATION THESE GENERAL NOTES AND
THE SPECIFICATIONS SHALL APPLY NOT ONLY TO THE GENERAL CONTRACTOR BUT TO ALL
SUBCONTRACTORS AND SUPPLIERS FOR THE PROJECT. THE WORD "CONTRACTOR" SHALL
HEREAFTER APPLY EQUALLY AND WITHOUT EXCEPTION TO ALL SUBS AND SUPPLIERS. ALL
CONTRACTORS ARE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH BOTH THESE
NOTES AND THE SPECIFICATIONS.
14. GENERAL NOTES ARE AN AID TO THE CONTRACTOR IN UNDERSTANDING THE WORK AND
SHOULD NOT BE CONSTRUED AS BEING COMPLETE IN EVERY DETAIL. IT IS THE EXPLICIT AND
SPECIFIC RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE, VERIFY THE EXISTING
CONDITIONS AND FAMILIARIZE HIMSELF THOROUGHLY WITH THE SCOPE OF WORK, AND
REPORT ALL DISCREPANCIES BETWEEN THE DRAWINGS AND THE ASSUMED OR ACTUAL
CONDITIONS TO THE ATTENTION OF THE DESIGNER (ARCHITECT).
15. NO ONE DRAWING OR SPECIFICATION SECTION SHALL "GOVERN". CONTRACTOR SHALL
CORRELATE WORK BETWEEN ARCHITECTURAL DRAWINGS AND SPECIFICATIONS AND
CONSULTANT DRAWINGS AND SPECIFICATIONS. CONTRACTOR SHALL ALSO CORRELATE
WORK BETWEEN DRAWINGS OF DIFFERENT SCALES WITHIN EACH SECTION. IT IS THE
EXPLICIT AND SPECIFIC RESPONSIBILITY OF THE CONTRACTOR TO EXAMINE THE CONTRACT
DOCUMENTS IN THEIR ENTIRETY, REPORT ALL DISCREPANCIES ENCOUNTERED THEREIN TO
THE ATTENTION OF THE DESIGNER AND AWAIT RESOLUTION BEFORE PROCEEDING WITH
ANY WORK AFFECTED BY SUCH DISCREPANCIES. WHERE THE REQUIREMENTS OF EITHER
THE GENERAL NOTES OR THE SPECIFICATIONS MAY BE AT VARIANCE WITH THE GENERAL
CONDITIONS, THE MORE RESTRICTIVE PROVISION SHALL GOVERN.
16. ALL LINES, SYMBOLS, NOTES, TONES, AND OTHER GRAPHIC DEVICES CONTAINED IN THE
CONTRACT DOCUMENTS CARRY SPECIFIC OR INFERENTIAL MEANING. ITEMS INDICATED IN
THESE WAYS ARE A PART OF THE SCOPE OF WORK AND WILL BE REQUIRED BY THE OWNER
AND DESIGNER TO BE INCLUDED IN THE SCOPE OF THE CONTRACTOR'S WORK WHETHER
THEY HAVE BEEN INCLUDED IN THE CONTRACTOR'S ORIGINAL BID OR NOT. ANY ITEMS WHICH
REQUIRE FURTHER CLARIFICATION BY THE DESIGNER FOR THE SPECIFIC BENEFIT OF THE
CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER FOR SUCH
CLARIFICATION BEFORE COMMENCEMENT OF ANY WORK.
17. DESIGN WORK IS THE RESPONSIBILITY OF THE DESIGNER. THE CONTRACTOR SHALL ASSUME
DESIGN LIABILITY AND ALL RESPONSIBILITY FOR CHANGES IN THE SCOPE OF WORK NOT
BROUGHT TO THE ATTENTION OF THE DESIGNER.
18. THE CONTRACTOR SHALL PAY SPECIFIC ATTENTION TO ALL DIMENSIONED OR INFERENTIAL
PLAN AND SECTIONAL SPECIAL RELATIONSHIPS, AND SHALL VERIFY ALL ALIGNMENTS
BEFORE COMMENCING WORK.
19. DIMENSIONS MARKED "VERIFY" ARE TO BE CHECKED FOR ACCURACY BY THE CONTRACTOR
AS WORK PROGRESSES, AND ALL DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION
OF THE DESIGNER BEFORE PROCEEDING.
20. DIMENSIONS MARKED "CLEAR" OR MINIMUM ARE NOT ADJUSTABLE WITHOUT THE
AUTHORIZATION FROM THE DESIGNER. "ALIGN" MEANS TO ACCURATELY LOCATE FINISHED
FACES IN THE SAME PLANE AS INDICATED.
21. CONTRACTOR SHALL NOT SCALE THE DRAWINGS, FIGURED DIMENSIONS ONLY ARE TO BE
USED FOR ALL ASPECTS OF THE WORK. ALL DIMENSIONS ARE TO FACE OF FINISH SURFACE,
U.O.N.
1. THE INTENT OF THE CONSTRUCTION DOCUMENTS IS TO RECONSTRUCT THE HOSPITAL BUILDING
IN ACCORDANCE WITH THE 2022 CBSC. SHOULD ANY CONDITION DEVELOP NOT COVERED BY
THE APPROVED CONSTRUCTION DOCUMENTS, WHEREIN THE FINISHED WORK WILL NOT COMPLY
WITH THE 2022 CBSC, AMENDED CONSTRUCTION DOCUMENTS (ACDS) DETAILING AND
SPECIFYING THE REQUIRED WORK SHALL BE SUBMITTED TO AND APPROVED BY THE AUTHORITY
HAVING JURISDICTION (AHJ) BEFORE PROCEEDING WITH THE WORK.
2. SUPPORTS AND ATTACHMENTS OF ALL EQUIPMENT TO BE INSTALLED AS A PART OF THIS
PROJECT SHALL BE DETAILED ON CONSTRUCTION DOCUMENTS, EXCEPT THOSE EXEMPT BY THE
2022 CBC SECTION 1617A.1.18.
EQUIPMENT SUPPORTS AND ATTACHMENTS SHALL BE APPROVED BY THE APPROPRIATE DESIGN
PROFESSIONAL OF RECORD (RDP) AND THE AHJ AS A PART OF FIELD REVIEWS/OBSERVATIONS.
THE INSPECTOR OF RECORD (IOR) SHALL ASSURE THAT THE ABOVE REQUIREMENTS ARE
ENFORCED.
3. WHEN INSTALLING DRILLED-IN ANCHORS IN EXISTING NON-PRESTRESSED REINFORCED
CONCRETE, USE A PACHOMETER OR GPR TO LOCATE STEEL TO AVOID CUTTING OR
DAMAGING THE EXISTING REINFORCING BARS. MAINTAIN A MINIMUM CLEARANCE OF ONE
INCH BETWEEN THE REINFORCEMENT AND THE DRILLED-IN ANCHOR AND OR PIN. SEE SHEET
S.3.1 FOR MORE NOTES
4. A PROJECT INSPECTOR EMPLOYED BY THE OWNER AND APPROVED BY THE AHJ SHALL
PROVIDE CONTINUOUS INSPECTION OF THE WORK. THE DUTIES OF THE INSPECTOR ARE
DEFINED IN PART 1,TITLE 24,CCR.
5. UNLESS OTHERWISE SPECIFIED, SPECIFIC REFERENCES TO CODES, REGULATIONS,
STANDARDS, MANUFACTURER'S INSTRUCTIONS, OR REQUIREMENTS OF REGULATORY
AGENCIES, WHEN USED TO SPECIFY REQUIREMENTS FOR MATERIALS OF DESIGN ELEMENTS
SHALL MEAN THE LATEST EDITION OF EACH IN EFFECT AT THE DATE OF SUBMISSION OF
BIDS, OR THE DATE OF THE CHANGE ORDER OR FIELD ORDER, AS APPLICABLE.
6. ALL RATED ASSEMBLIES NOTED HERE ARE APPLICABLE ONLY TO MANUFACTURERS
SPECIFIED IN THESE ASSEMBLIES. IF AN ALTERNATE MANUFACTURER IS PROPOSED, THE
CONTRACTOR MUST SUBMIT ALTERNATE & LISTED ASSEMBLIES FOR REVIEW AND
APPROVAL BY THE OWNERS REP. PRIOR TO BEGINNING ANY PARTITION WORK.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK BEGUN OR COMPLETED WHICH DOES
NOT CONFORM TO ASSEMBLIES LISTED.
7. ALL WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS. UNLESS OTHERWISE
REQUESTED/DETERMINED BY THE OWNER AND SHALL BE DONE ON AN OVERTIME BASIS TO
BE COORDINATED WITH THE OWNER'S REPRESENTATIVE AS REQUIRED.
8. FOR DETAILED REQUIREMENTS FOR THE USE OF PRE-APPROVED PIPES, DUCTS, AND
CONDUITS SEISMIC BRACING SYSTEMS, SEE MECHANICAL & ELECTRICAL DRAWINGS.
V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/16/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #23790-8
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
DSA STAMP
MEDICATION
DISPENSING UNIT
INSTALLATION
Client Agency
JCCA
385 VAN NESS AVENUE, SUITE 208
ASSOCIATES, INC.
J.C. CHANG &
ARCHITECTS PLANNERSENGINEERS
TORRANCE, CALIFORNIA 90501
PH (310) 212-7644
FAX (310) 212-5272
09/30/2025
DEPARTMENT OF STATE HOSPITALS
100% CONSTRUCTION DOCUMENTS
F
IL
E C
U s e rs
\J E R
E M
Y \A p p D a ta
\L o c a l\ T e m p \A c P u b lis h \2
-A
.d w g
D A T E /T
IM
E O c t :5
A M
JCCA
DSH
OVERALL SITE PLAN
SCALE: N 0 24020 FEET120
1" = 120'
SEE SHEETS
06-A0.1, 536 BUILDING -
FIRST FLOOR OVERALL FLOOR PLAN.
SEE SHEETS
03-A0.1, 235 BUILDING - FIRST FLOOR OVERALL FLOOR PLAN,
03-A0.2, 235 BUILDING - SECOND FLOOR OVERALL FLOOR PLAN &
03-A0.3, 235 BUILDING - THIRD FLOOR OVERALL FLOOR PLAN.
SEE SHEETS
04-A0.1, 243 BUILDING - FIRST FLOOR OVERALL FLOOR PLAN &
04-A0.2, 243 BUILDING - SECOND FLOOR OVERALL FLOOR PLAN.
SEE SHEETS
01-A0.1, 30 BUILDING - FIRST FLOOR OVERALL FLOOR PLAN &
01-A0.2, 30 BUILDING - SECOND FLOOR OVERALL FLOOR PLAN.
SEE SHEETS
02-A0.1, 70 BUILDING - FIRST FLOOR
OVERALL FLOOR PLAN &
02-A0.2, 70 BUILDING - SECOND
FLOOR OVERALL FLOOR PLAN.
SEE SHEETS
05-A0.1, 245 BUILDING -
FIRST FLOOR OVERALL FLOOR PLAN.
OVERALL SITE PLAN
00-A0.2
SEE SHEETS
07-A0.1, 512 BUILDING -
FIRST FLOOR OVERALL FLOOR PLAN.
V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/16/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #23790-8
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
DSA STAMP
MEDICATION
DISPENSING UNIT
INSTALLATION
Client Agency
JCCA
385 VAN NESS AVENUE, SUITE 208
ASSOCIATES, INC.
J.C. CHANG &
ARCHITECTS PLANNERSENGINEERS
TORRANCE, CALIFORNIA 90501
PH (310) 212-7644
FAX (310) 212-5272
09/30/2025
DEPARTMENT OF STATE HOSPITALS
100% CONSTRUCTION DOCUMENTS
F
IL
E C
U s e rs
\J E R
E M
Y \A p p D a ta
\L o c a l\ T e m p \A c P u b lis h \2
-A
.d w g
D A T E /T
IM
E O c t :5
A M
JCCA
DSH
00-A0.3
ELECTRICAL SYMBOLS,
ABBREVIATIONS, AND
GENERAL NOTES
GENERAL NOTES
1. ALL WORK MUST BE PERFORMED IN COMPLIANCE WITH APPLICABLE CODES AND
STANDARDS. SEE T0.1 FOR A LIST OF APPLICABLE CODES AND STANDARDS.
2. CEC 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR
CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE
UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION.
3. CEC 130.5(C): VOLTAGE DROP: THE MAXIMUM COMBINED VOLTAGE DROP ON BOTH
INSTALLED FEEDER CONDUCTORS AND BRANCH CIRCUIT CONDUCTORS TO THE FARTHER
CONNECTED LOAD OR OUTLET SHALL NOT EXCEED 5 PERCENT.
4. ALL CABLE/WIRE, CONDUIT RUNS ARE SHOWN DIAGRAMMATICALLY & THEY SHALL BE
ROUTED TO SUIT ACTUAL FIELD CONDITIONS, EXCEPT WHERE LOCATIONS ARE EXPLICITLY
DIMENSIONED ON THE DRAWINGS.
5. THE ELECTRICAL CONSTRUCTION DRAWINGS PROVIDED HEREIN ARE DIAGRAMMATIC AND
SYMBOLIC IN REPRESENTATION. LOCATIONS DEPICTED ON THE DRAWINGS FOR ELECTRICAL
EQUIPMENT/DEVICES (MOTORS, STARTERS, DISCONNECT SWITCHES, RECEPTACLES,
JUNCTION/OUTLET BOXES, CONTROL SWITCHES, EQUIPMENT RACKS, SMALL
TRANSFORMERS, ETC.) ARE ONLY APPROXIMATE. FURTHERMORE, THE EQUIPMENT/DEVICE
DEPICTIONS ARE GENERALLY SYMBOLIC AND NOT DRAWN TO SCALE.
6. IN EVENT OF CONFLICT OR DISCREPANCY BETWEEN DRAWINGS, SPECIFICATIONS,
CONTRACT DOCUMENTS, SPECIFICATIONS, DRAWINGS AND SITE CONDITIONS, THE
CONTRACTOR SHALL PROVIDE THE MORE STRINGENT OF THE DRAWINGS, SPECIFICATIONS,
AND CONTRACT DOCUMENTS FOR THE CONSTRUCTIONS AND BIDDING PURPOSES.
7. ELECTRICAL DRAWINGS INDICATE NEW WORK, UNLESS OTHERWISE NOTED. EXISTING
ELECTRICAL SYSTEMS ARE NOT SHOWN EXCEPT WHERE INTERFACING IS REQUIRED.
8. ALL NEW BOXES, PANELS, OUTLET COVERS, ENCLOSURES, ETC. MOUNTED ON THE
EXTERIOR OF ANY STRUCTURE SHALL BE WEATHERPROOF (NEMA 3R MINIMUM) & ALSO
PAINTED TO MATCH THE EXISTING BUILDING/STRUCTURE.
9. ALL EXISTING SURFACES DAMAGED BY NEW CONSTRUCTION, SHALL BE PATCHED, OR
REPAINTED TO MATCH EXISTING CONDITIONS, PAINTED SURFACE SHALL BE PAINTED FROM
BREAK TO BREAK. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO PATCH & REPAIR ALL
DAMAGE TO EXISTING SURFACES AND FINISHES. FURTHERMORE, THE AFFECTED AREA(S) OF
WORK SHALL BE REPAIRED TO MATCH THE FINISH THAT WAS PREVIOUSLY EXISTING, PRIOR
TO THE COMMENCEMENT OF WORK.
10. RUN CONDUITS CONCEALED IN WALLS AND CEILINGS UNLESS OTHERWISE NOTED. CUT
EXISTING WALLS AS REQUIRED. PATCH AND PAINT TO MATCH EXISTING SURFACE.
11. UPDATE ALL POWER PANEL DIRECTORIES AND ELECTRICAL OUTLET IDENTIFICATION LABELS
(KROYTAPE) TO REFLECT NEW CONSTRUCTION.
12. ALL FLEX AND SEALTIGHT CONDUIT SHALL HAVE A GROUND CONDUCTOR.
13. ALL MATERIALS AND WORKS ARE NEW, UNLESS OTHERWISE NOTED. EXISTING ELECTRICAL
SYSTEMS ARE NOT SHOWN EXCEPT WHERE INTERFACING IS REQUIRED.
14. MAINTAIN CONTINUITY OF ALL EXISTING CIRCUITS OR PORTIONS THEREOF AFFECTED BY
NEW WORK.
15. CONTRACTOR SHALL VISIT AND FAMILIARIZE AT THE SITE PRIOR TO START OF PROJECT.
COORDINATE WITH OWNER REPRESENTATIVE FOR EXACT LOCATION OF ALL EQUIPMENT.
16. SEISMIC ANCHORAGE OF ALL NEW AND EXISTING PIPING, CONDUIT, DUCTWORK, EQUIPMENT, PANELS, ETC. SHALL BE BY FOLLOWING THE MANUFACTURERS SPECIFICATIONS IN
ACCORDANCE WITH THE 2022 CBC AND THE LATEST ISSUE OF "ENGINEERED SEISMIC
BRACING OF SUSPENDED UTILITIES" AS PUBLISHED BY THE INTERNATIONAL SEISMIC
APPLICATION TECHNOLOGY (ISAT) OPA-0485, MASON INDUSTRIES OPA-0349, TOLCO
OPA-0300, COOPER B-LINE OPA-0114, OR M.W. SAUSSE OPA-0029 OR EQUAL.
17. CONDUIT FITTINGS FOR USE IN EMT RUNS SHALL BE GALVANIZED STEEL CONNECTORS AND
COUPLINGS SHALL BE WATERTIGHT TYPE.
18. ALL SINGLE PHASE CIRCUITS SHALL HAVE A DEDICATED NEUTRAL.
19. ALL CONDUITS SHALL BE PROVIDED AN EQUIPMENT GROUNDING CONDUCTOR SIZED PER
CEC 250.
20. ALL NEW (ADDITIONAL) METALLIC STRUCTURES AND EQUIPMENT FABRICATED WITH
METALLIC MATERIALS SUCH AS GENERATORS, MOTOR FRAME, ENCLOSURES, ETC, PANELS,
RACEWAY SHALL BE PERMANENTLY & EFFECTIVELY GROUNDED, WHETHER SHOWN ON
DRAWING OR NOT. GROUND CABLE SHALL BE CONNECTED TO COLD WATER PIPE PER CEC
250.52(A)(1), TO BUILDING GROUNDING PER CEC 250.52(A)(2) OR CONNECTED TO GROUND
ROD PER CEC 250.52(A)(5).
21. OWNER RESERVES THE RIGHT TO REQUIRE MINOR CHANGES IN LOCATION OF OUTLETS OR
EQUIPMENT PRIOR TO ROUGHING-IN WITHOUT INCURRING ANY ADDITIONAL COST OR
CHARGES.
22. DURING CONSTRUCTION, DO NOT INTERRUPT OR IMPEDE OPERATION AND WORK IN
ADJACENT AREAS.
23. UPON COMPLETION OF ALL WORK, THOROUGHLY CLEAN ALL EQUIPMENT FROM INSIDE AND
OUTSIDE OF EQUIPMENT. REMOVE ALL TRACES OF SOIL, DUST, LABELS, GREASE, OIL, AND
FOREIGN MATERIALS. CLEANUP AND REMOVE FROM THE PREMISES ALL DEBRIS AND
SURPLUS MATERIAL CAUSED BY THIS WORK.
24. WHERE THERE IS A CONFLICT BETWEEN THE CONSTRUCTION DOCUMENTS & ANY RELEVANT
CODES, THE CODES SHALL GOVERN, EXCEPT WHERE THE DRAWINGS INDICATE A QUALITY
LEVEL SUPERIOR TO THAT SPECIFIED BY THE CODES.
25. THE WORD "PROVIDE" MEANS THAT THE CONTRACTOR SHALL FURNISH, INSTALL, ADJUST,
TEST, AND INTEGRATE INTO A COMPLETE SYSTEM THE ITEM INDICATED INCLUDING ALL
HARDWARE, WIRING AND MISCELLANEOUS ITEMS AS NECESSARY FOR A COMPLETE AND
OPERATIONAL SYSTEM.
26. ALL RECEPTACLES AND SWITCHES SHALL BE HOSPITAL OR CONSTRUCTION GRADE RATED.
27. ALL BRANCH CIRCUIT BREAKERS TO BE 20A MINIMUM.
28. ALL RECEPTACLES AND SWITCHES TO BE 20A RATED UNLESS OTHERWISE NOTED.
ABBREVIATIONS SYMBOL LIST
P4-10 BRANCH CIRCUIT DESTINATION (PANEL NAME-CIRCUIT
NUMBER)
HOMERUN INDICATES PROVIDING CONDUIT AND
CONDUCTORS
MINIMUM CONDUIT SIZE: 3/4"
MINIMUM CONDUCTOR SIZE: #12AWG
#12 AWG FOR CIRCUITS UP TO 100'
#10 AWG FOR CIRCUITS FROM 100' TO 200'
#8 AWG FOR CIRCUIT GREATER THAN 200'
PROVIDE 3/4"C-2#12+1#12G WHERE NO CONDUIT/WIRE SIZE IS
STATED.
PROVIDE DEDICATED NEUTRAL FOR ALL BRANCH CIRCUIT
WIRING.
CONTRACTOR RESPONSIBLE FOR DE-RATING CONDUIT WITH
MORE THAN SIX CURRENT CARRYING CONDUCTORS PER CEC
310.
JUNCTION BOX
20A, 125V WALL-MOUNTED DUPLEX RECEPTACLE (NEMA 5-20R)
SUBSCRIPTS DENOTE THE FOLLOWING:
"WP" - WEATHERPROOFED
"GFCI" - GROUND FAULT CURRENT INTERUPTER
GFCI
WP
DATA PORT RECEPTACLE, # INDICATES NUMBER OF DROPS#
DISTANCE
DENOTES EXISTING
CIRCUIT BREAKER
EACH
COPPER
GROUND
MINIMUM
AMPERE
CIRCUIT
LOW VOLTAGE
AMPERE
INTERRUPTING
CAPACITY
ABOVE FINISHED
FLOOR
NOT TO SCALE
WEATHER PROOFWP
SWITCHBOARDSWBD
TYP. TYPICAL
UG UNDERGROUND
SWITCHSW
PULL BOXPB
SLD SINGLE LINE DIAGRAM
POLEP
PANELBOARDPNL
(R) RELOCATED
SUB SUBSTATION
NEW(N)
TIME DELAY
UNLESS
OTHERWISE
NOTED
UON
TRANSFORMERXFMR,
TRANSF.
VD VOLTAGE DROP
TD
DEMOLITION
D
(E)
CB
EA
CU
GND, G
MIN
A
CKT
LV
AIC
AFF
NTS
(D)
LIGHT, THIN LINES INDICATE EXISTING.
HEAVY, THICK LINES INDICATE NEW
HEAVY, SHORT DASHED LINES INDICATE
DEMOLITION OR REMOVAL
THIS SYMBOLOGY TO BE USED BY ELECTRICAL AND LAYOUT FOR ALL
FLOOR PLANS, EQUIPMENT, DEVICES, UTILITIES, ETC., SHOWN ON
DRAWINGS.
TYPICAL PLAN LEGEND
V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/16/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
00-A3.1
DETAIL SHEET
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #23790-8
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
DSA STAMP
MEDICATION
DISPENSING UNIT
INSTALLATION
Client Agency
JCCA
385 VAN NESS AVENUE, SUITE 208
ASSOCIATES, INC.
J.C. CHANG &
ARCHITECTS PLANNERSENGINEERS
TORRANCE, CALIFORNIA 90501
PH (310) 212-7644
FAX (310) 212-5272
09/30/2025
DEPARTMENT OF STATE HOSPITALS
100% CONSTRUCTION DOCUMENTS
F
IL
E C
U s e rs
\J E R
E M
Y \A p p D a ta
\L o c a l\ T e m p \A c P u b lis h \2
-A
.d w g
D A T E /T
IM
E O c t :5
A M
JCCA
DSH
BACK WALL
S
ID
E W
A L L W
H E R
E O
C C
U R S
L
C L
CL
CL
C
1'-111
"4"
MIN.
T Y P
M
IN
PERIMETER OUTLINE OF EQUIPMENT
SEE EQUIPMENT
SCHEDULE AND
STRUCTURAL DRAWINGS
FOR BOLT PATTERN
SEE EQUIPMENT
SCHEDULE AND
STRUCTURAL DRAWINGS
FOR BOLT PATTERN
OPM-0406-13 ANCHOR PLATE - SIDE BY SIDE MOUNTING DIMENSIONS - DM UNITS
SCALE: 00-A3.1
3" = 1'-0"
0 2 84 INCHES 1
MIN.
A D
J A C
E N
T E
Q U
IP
M
E N
T W
H E R
E O
C C
U R
S
4"
MIN.
ALIGN PLATES
4"
MIN.
T Y P
M
IN
L
1 1
5 8
1'-1013
C L
C
OPM-0406-13 ANCHOR PLATE - 8 BOLT PATTERN
SCALE: 00-A3.1
3" = 1'-0"
0 2 84 INCHES 1
PERIMETER OUTLINE
OF EQUIPMENT
8 BOLT PATTERN
ANCHOR PLATE
1'-01
PERMANENT STOP/ALIGNMENT
FLOOR PLATE
ANCHOR PLATE
BACK WALL
S
ID
E W
A L L W
H E R
E O
C C
U R S
S3.1
A D
J A C
E N
T E
Q U
IP
M
E N
T W
H E R
E O
C C
U R
S
4"
MIN.
BACK WALL
PERIMETER OUTLINE
OF EQUIPMENT
20 BOLT PATTERN
ANCHOR PLATE
S
ID
E W
A L L W
H E R
E O
C C
U R S
4"
MIN.
T Y P
M
IN
C L
C L
1 1
5 8
1'-1013
1'-01
PERMANENT STOP/ALIGNMENT
FLOOR PLATE
ANCHOR PLATE
OPM-0406-13 ANCHOR PLATE - 20 BOLT PATTERN
SCALE: 00-A3.1
3" = 1'-0"
0 2 84 INCHES 1
S3.1
A D
J A C
E N
T E
Q U
IP
M
E N
T W
H E R
E O
C C
U R
S
4"
MIN.
(OFVI) OWNER FURNISHED / VENDOR INSTALLED
EQUIPMENT & ACCESSORY SCHEDULE
DESCRIPTION
GENERAL
NO MANUFACTURER WGT
/LBS
ANCHORAGE
SUPPORT
ELEMENT
DIMENSIONS (INCH)
W D H
REMARKS
COORDINATE W/
VENDOR FOR SPECIAL
NUMBER
DETAIL
INSTALLATION REQ'MTS.
NOTES:
MEDSELECT FLEX CABINET
DRAWER MODULE/MONITOR & KEYBOARD
(DM/DT/UI)
ARxIUM
951 22.8 27.6 39.4 NEW FLOOR
MEDSELECT FLEX CABINET
DRAWER MODULE/CPU-UPS
(DM/DT-CPU)
ARxIUM
994 22.8 27.6 46.1 NEW FLOOR
MEDSELECT FLEX CABINET
DRAWER MODULE/MONITOR & KEYBOARD
(DM/DT/UI)
ARxIUM
951 22.8 27.6 39.4 NEW FLOOR
MEDSELECT FLEX CABINET
DRAWER MODULE/DT-CPU
(DM/DT-CPU)
ARxIUM
994 22.8 27.6 46.1 NEW FLOOR
MS-1.1
MS-1.2
MS-2.1
MS-2.2
00-A3.1
S3.1
00-A3.1
S3.1
00-A3.1
S3.1
00-A3.1
S3.1
FP-01FP-01 FP-01 FP-01
MEDSELECT FLEX CABINET
SUPPLY CABINET MODULE/CPU
(SCM/DT-CPU)
ARxIUM
763 22.8 27.6 39.4 NEW FLOOR
MEDSELECT FLEX CABINET
DRAWER MODULE/CPU-UPS MONITOR & KEYBOARD
(DM/DT-CPU/DT-UI)
ARxIUM
1020 22.8 27.6 46.1 NEW FLOORMS-2.3
00-A3.1
S3.1
MEDSELECT FLEX CABINET
TOWER MODULE - CENTRACK
(TM)
ARxIUM
1339 28 29 84.7 NEW FLOOR
FLOOR MOUNTING PLATE - OPM-0406 - 13
ARxIUM
N/A 10.5 22 2.125 NEW FLOORFP-01
00-A3.1 1,2&3
COORDINATION OF FLOOR ANCHOR PLATE LOCATIONS IN EACH ROOM IS REQUIRED PER
NOTES ON FLOOR PLANS, ELEVATIONS AND DETAILS. SEE EQUIPMENT NUMBER DESIGNATION
ON FLOOR PLANS AND ELEVATIONS TO DETERMINE REQUIRED BOLT PATTERN.
(OFCI) OWNER FURNISHED / CONTRACTOR INSTALLED
MS-3.1
MS-4.1
00-A3.1
S3.1
00-A3.1
S3.1
MEDSELECT FLEX CABINET
CDM MODULE
(CDM)
ARxIUM
269 22.8 27.8 14.3 NEW FLOORMS-5.1
S3.1
MEDSELECT FLEX CABINET
CDM MODULE
(CDM)
ARxIUM
269 22.8 27.8 14.3 NEW FLOORMS-5.2
S3.1
V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/16/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
UP
UP
U P
U P
UP
U P
U P
UP
UP UP
UP
UP
U P
MED RM
33-19
UNIT 30 UNIT 31
UNIT 33 UNIT 32
30 BUILDING
MED RM
30-19
32-19
MED RM
31-19
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #23790-8
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
DSA STAMP
MEDICATION
DISPENSING UNIT
INSTALLATION
Client Agency
JCCA
385 VAN NESS AVENUE, SUITE 208
ASSOCIATES, INC.
J.C. CHANG &
ARCHITECTS PLANNERSENGINEERS
TORRANCE, CALIFORNIA 90501
PH (310) 212-7644
FAX (310) 212-5272
09/30/2025
DEPARTMENT OF STATE HOSPITALS
100% CONSTRUCTION DOCUMENTS
F
IL
E C
U s e rs
\J E R
E M
Y \A p p D a ta
\L o c a l\ T e m p \A c P u b lis h \2
-A
.d w g
D A T E /T
IM
E O c t :5
A M
JCCA
DSH
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
AC.
AC.
AC.
AC.
AC.
AC.
CONC.
CONC.
CO NC.
DRIVE
DRIVEDRIVE
CONC.
AC.
AC.
AC.
AC.
STOP536
BUILDING KEYPLAN
N 01-A0.1
BUILDING 30 - FIRST FLOOR
OVERALL PLAN
0 202 FEET 10
1/16" = 1'-0"
BUILDING 30 - FIRST FLOOR OVERALL PLAN
SCALE: N
SEE SHEETS
01-A1.1 FOR DEMOLITION PLANS &
01-A2.1 FOR NEW WORK PLANS
SEE SHEETS
01-A1.1 FOR DEMOLITION PLANS &
01-A2.1 FOR NEW WORK PLANS
V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/16/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
D N
DN DN
D N
DN
U P
D N
D N
D N
D N
DN
DN
DN
D N
MED RM
37-19
UNIT 34 UNIT 35
UNIT 37 UNIT 36
30 BUILDING
MED RM
34-19
MED RM
36-19
MED RM
35-19
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #23790-8
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
DSA STAMP
MEDICATION
DISPENSING UNIT
INSTALLATION
Client Agency
JCCA
385 VAN NESS AVENUE, SUITE 208
ASSOCIATES, INC.
J.C. CHANG &
ARCHITECTS PLANNERSENGINEERS
TORRANCE, CALIFORNIA 90501
PH (310) 212-7644
FAX (310) 212-5272
09/30/2025
DEPARTMENT OF STATE HOSPITALS
100% CONSTRUCTION DOCUMENTS
F
IL
E C
U s e rs
\J E R
E M
Y \A p p D a ta
\L o c a l\ T e m p \A c P u b lis h \2
-A
.d w g
D A T E /T
IM
E O c t :5
A M
JCCA
DSH
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
AC.
AC.
AC.
AC.
AC.
AC.
CONC.
CONC.
CO NC.
DRIVE
DRIVEDRIVE
CONC.
AC.
AC.
AC.
AC.
STOP536
BUILDING KEYPLAN
N 01-A0.2
BUILDING 30 - SECOND
FLOOR OVERALL PLAN
0 202 FEET 10
1/16" = 1'-0"
BUILDING 30 - SECOND FLOOR OVERALL PLAN
SCALE: N
SEE SHEETS
01-A1.1 FOR DEMOLITION PLANS &
01-A2.1 FOR NEW WORK PLANS
SEE SHEETS
01-A1.1 FOR DEMOLITION PLANS &
01-A2.1 FOR NEW WORK PLANS
V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/16/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
MED RM
31-194
1 2
MED RM
32-194
1 2
MED RM
33-19 4
MED RM
34-19 4
MED RM
35-194
1 2
36-19
1 2
3 5
37-19
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #23790-8
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
DSA STAMP
MEDICATION
DISPENSING UNIT
INSTALLATION
Client Agency
JCCA
385 VAN NESS AVENUE, SUITE 208
ASSOCIATES, INC.
J.C. CHANG &
ARCHITECTS PLANNERSENGINEERS
TORRANCE, CALIFORNIA 90501
PH (310) 212-7644
FAX (310) 212-5272
09/30/2025
DEPARTMENT OF STATE HOSPITALS
100% CONSTRUCTION DOCUMENTS
F
IL
E C
U s e rs
\J E R
E M
Y \A p p D a ta
\L o c a l\ T e m p \A c P u b lis h \2
-A
.d w g
D A T E /T
IM
E O c t :5
A M
JCCA
DSH
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
AC.
AC.
AC.
AC.
AC.
AC.
CO NC.
CONC.
CONC.
DRIVE
DRIVE
DRIVE
CO NC.
AC.
AC.
AC.
AC.
STOP536
BUILDING KEYPLAN
N 01-A1.1
BUILDING 30 - FIRST AND
SECOND FLOOR
DEMOLITION PLANS
DEMOLITION KEYNOTES:
REMOVE (E) MEDICATION DISPENSING UNITS.
REMOVE FLOOR MOUNTING PLATES AND CUT (E) 5/8"
DIAMETER ANCHORS FLUSH WITH CONCRETE AND GRIND
SMOOTH TO PROVIDE A SMOOTH BEARING SURFACE.
REMOVE CABINET DOORS WHERE BLOCKED BY PLACEMENT
OF NEW EQUIPMENT - SEE NEW EQUIPMENT PLAN.
(E) EQUIPMENT TO REMAIN.
DEMOLISH RECEPTACLE. PROTECT BACKBOX AND BRANCH
CIRCUIT, AND PREPARE TO INTERCEPT AND EXTEND TO (N)
RECEPTACLE IN NEW WORK.
DISCONNECT CAT6 CABLES AND REMOVE TWO RJ-45 PORTS
FROM (E) DATA WALL PLATE. PROTECT BACKBOX AND
ETHERNET CABLE, AND PREPARE TO EXTEND DISCONNECTED
CABLES IN NEW WORK.
BUILDING 30 - FIRST FLOOR DEMOLITION PLAN
SCALE: 0 81 FEET4
1/4" = 1'-0"
BUILDING 30 - SECOND FLOOR DEMOLITION PLAN
SCALE: 0 81 FEET4
1/4" = 1'-0"
2 N
N
UNIT 30 - MED RM - 30-19 UNIT 31 - MED RM - 31-19 UNIT 32 - MED RM - 32-19 UNIT 33 - MED RM - 33-19
UNIT 34 - MED RM - 34-19 UNIT 35 - MED RM - 35-19 UNIT 36 - MED RM - 36-19 UNIT 37 - MED RM - 37-19
GENERAL DEMOLITION NOTES:
1. THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WITH THE
FACILITY THE DETAILS FOR DEMOLITION AND CONSTRUCTION
ACTIVITIES FOR EACH PROJECT LOCATION SO PREPARATIONS AND
ARRANGEMENTS CAN BE MADE TO MAINTAIN OPERATIONS AND TO
MINIMIZE DISTRUPTIONS TO HOSPITAL SERVICES.
2. THE CONTRACTOR SHALL COORDINATE WITH THE FACILITY TO
ARRANGE FOR THE REMOVAL OR MOVEMENT OF ANY FURNITURE,
EQUIPMENT, OR APPURTENANCES, NOT WITHIN THE SCOPE OF
WORK, NECESSARY TO ACCOMMODATE DEMOLITION AND
CONSTRUCTION ACTIVITIES.`
3. THE DEMOLITION DRAWINGS ARE DIAGRAMMATIC AND DO NOT
SHOW EXACT AMOUNT OF REMOVAL. THE CONTRACTOR SHALL VISIT
THE JOB SITE AND DETERMINE THE FULL EXTENT OF THE
DEMOLITION WORK INVOLVED PRIOR TO SUBMITTING A BID.
4. PROTECT EXISTING BUILDING AND SITE FROM ANY POSSIBLE
DAMAGE DUE TO THE CONSTRUCTION WORK INCLUDING THE
DELIVERY OF EQUIPMENT AND MATERIALS AND REMOVAL OF
EQUIPMENT AND DEBRIS.
5. THE CONTRACTOR SHALL PROTECT AND COVER ALL FIXTURES AND
EQUIPMENT IN AREAS AFFECTED BY WORK, AND UPON COMPLETION
OF WORK, SHALL THOROUGHLY CLEAN ALL FIXTURES, EQUIPMENT
WALLS, FLOOR AND HARDWARE.
6. PLASTIC FILM WHEN USED FOR DUST PROTECTION, SHALL BE FLAME
RESISTANT.
7. REMOVE FROM SITE AND LEGALLY DISPOSE OF ALL REFUSE, DEBRIS,
RUBBISH, AND OTHER MATERIALS RESULTING FROM DEMOLITION
OPERATIONS DAILY. CONTRACTOR SHALL ASSUME ALL COSTS OF
DISPOSAL OF DEBRIS FROM DEMOLISHED WORK. SITE TO BE LEFT
BROOM CLEAN EVERY DAY.
8. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/CONSTRUCTION
MANAGER AFTER DEMOLITION OF ANY EXPOSED, PREVIOUSLY
HIDDEN CONDITIONS THAT REQUIRE INSPECTION FOR
COORDINATION WITH NEW CONSTRUCTION.
9. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/CONSTRUCTION
MANAGER OF ANY CONDITION FOUND TO EXIST WHICH IS NOT
CONSISTENT WITH THE CONTRACT DOCUMENTS.
10. WORK AREAS ARE TO REMAIN SECURE AND LOCKABLE DURING
CONSTRUCTION AS REQUIRED BY USER/ OWNER/ BUILDING
MANAGEMENT CONTRACTOR SHALL COORDINATE WITH USER/
OWNER/ BUILDING MANAGEMENT AS REQUIRED TO ENSURE
SECURITY.
V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/16/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
MS-2.1
00-A3.1
MS-2.2
(SIM.)
01-A4.1
GFCI
MED RM
31-19
(SIM.)
MS-2.1
00-A3.1
MS-2.2
01-A4.1
GFCI
MED RM
32-19
MS-2.1
MS-2.2
(SIM.)
00-A3.1
01-A4.1
MED RM
33-19
MS-2.1
MS-2.2
(SIM.)00-A3.1
01-A4.1
GFCI
MED RM
34-19
00-A3.1
(SIM.)
01-A4.2
MS-1.1
MS-1.2 1
MED RM
35-19
(SIM.) 00-A3.1
01-A4.2
MS-1.1
MS-1.21
MED RM
36-19
(SIM.)
00-A3.1
01-A4.2
MS-1.1
MS-1.2
MED RM
37-19
(SIM.)
00-A3.1
01-A4.2
MS-1.1
MS-1.2
GFCI
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #23790-8
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
DSA STAMP
MEDICATION
DISPENSING UNIT
INSTALLATION
Client Agency
JCCA
385 VAN NESS AVENUE, SUITE 208
ASSOCIATES, INC.
J.C. CHANG &
ARCHITECTS PLANNERSENGINEERS
TORRANCE, CALIFORNIA 90501
PH (310) 212-7644
FAX (310) 212-5272
09/30/2025
DEPARTMENT OF STATE HOSPITALS
100% CONSTRUCTION DOCUMENTS
F
IL
E C
U s e rs
\J E R
E M
Y \A p p D a ta
\L o c a l\ T e m p \A c P u b lis h \2
-A
.d w g
D A T E /T
IM
E O c t :5
A M
JCCA
DSH
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
DIRT
AC.
AC.
AC.
AC.
AC.
AC.
CO NC.
CONC.
CONC.
DRIVE
DRIVE
DRIVE
CO NC.
AC.
AC.
AC.
AC.
STOP536
BUILDING KEYPLAN
N 01-A2.1
BUILDING 30 - FIRST AND
SECOND FLOOR NEW WORK
PLANS
UNIT 30 - MED RM - 30-19 UNIT 31 - MED RM - 31-19 UNIT 32 - MED RM - 32-19 UNIT 33 - MED RM - 33-19
BUILDING 30 - FIRST FLOOR NEW WORK PLAN
SCALE: 0 81 FEET4
1/4" = 1'-0"
BUILDING 30 - SECOND FLOOR NEW WORK PLAN
SCALE: 0 81 FEET4
1/4" = 1'-0"
2 N
UNIT 34 - MED RM - 34-19 UNIT 35 - MED RM - 35-19 UNIT 36 - MED RM - 36-19 UNIT 37 - MED RM - 37-19
NEW WORK KEYNOTES:
LOCATE (N) FLOOR PLATES PER DETAIL : SUCH THAT
THE DISPENSING UNITS ARE AS CLOSE TO CENTERED IN THE
SPACE AS POSSIBLE, ALLOWING SUFFICIENT SPACE TO
ACHIEVE COMPLETE AND COMPLIANT ANCHOR
INSTALLATIONS.
REMOVE CABINET DOORS WHERE BLOCKED BY PLACEMENT
OF NEW EQUIPMENT.
PATCH AND PAINT WALL TO MATCH WHERE (E) EQUIPMENT
WAS REMOVED.
(E) EQUIPMENT TO REMAIN.
PROVIDE 120V, 20A, GFCI RECEPTACLE (NEMA 5-20R).
INTERCEPT AND EXTEND (E) BRANCH CIRCUIT FROM DEMO
WORK. PROVIDE SURFACE MOUNTED WIREMOLD TO SERVICE
NEW EQUIPMENT CONFIGURATIONS. V.I.F.
PROVIDE…