4,000 GALLON WATER TRUCK
EQUIPMENT SPECIFICATIONSMEETS OR EXCEEDS

(Yes or No)

CHASSISconventional cab, 2-door chassis with air brakes. 6X4
GVRW66,000 lbs or greater
FRONT AXLE20,000 lbs or greater. Steel wheels.
REAR AXLES46,000 lbs total or greater. Driver controlled locking differentials. Traction Mud and Snow Tires on Rear Axles. Steel wheels.
ENGINE395 horsepower or greater. 1700 lb/ft of torque or greater. To include jake brake with 3 settings.
TRANSMISSION13 speed manual
BATTERIESMaintenance free with plug in battery tender. Master power disconnect switch. Jumpstart post that are easily accessible. Adjustable tilt and telescoping steering column.
TRUCK COLORwhite
CABCab with air suspension ride. Driver and passenger seats with air ride suspension. Cab heat, defrost and air conditioning. Radio with Bluetooth connectivity for phone for hands free during emergency operations on fires. 12V power supply outlet in dash. Adjustable tilt and telescoping steering column. Motorized mirrors. Electric and air horn. Emergency equipment (includes in-cab fire extinguisher & emergency triangles)
FENDER SKIRTINGSkirted fenders shall be fabricated from stainless steel and attached to the tank over the drive tires. Mud flaps to be black rubber; located front and rear of drive tires.
REAR BUMPERTo include a rear bumper or push bar.
FUELDiesel fuel with 88 gallon tank or greater.
TANK4,000 gallons rectangular oval barrel no slope, made of 7 gauge T-304L 2B stainless steel. Heads and baffles made of 10 gauge T-304L stainless steel, dished and flanged
MOUNTINGHeavy Duty spring loaded mounting assemblies installed along tank frame as required with rubber mounting sill installed full length of tank between chassis and tank frame; rubber sill shall be vulcanized to a stainless steel backing plate.
MANHOLEOne (1) each 25” neck ring welded in shell at top center of tank. Lid provided be easily removable. Manhole to also be fill point to allow for air gap filling. 3 inch piping to discharge over manhole to allow for air gap. Piping should be mounted to top of tank and down back where it is plumbed to back with inlet at frame height for fill. Should have ball valve at inlet end to shut off.
TOP FILLOne (1) each 2-1/2" air gap top fill with stainless steel pipe. Plumbing to begin at curbside rear of tank and go up back of rear head, then forward to manhole. A pivotal joint shall be installed at manhole to allow neck of fill pipe to be moved out of the way of the manhole. Inlet to have 2 1/2 inch stainless steel female camlock adapter with 2 1/2 inch ball valve with in 12 inches of camlock to shut off to prevent discharge of stored water in piping out of inlet when disconnecting.
CONTROLSSwitches controlling each spray option and PTO shall be mounted inside the cab on a console between the seats. Each switch shall be labeled for function.
SIGHT GAUGES5/8 clear tubing type with ball inside, resistant to sunlight to display tank level. 1 at driver side front of tank to be visible in mirror from drivers seat. 1 at rear of tank near center so as to extend to nearly the top of tank.
WALKWAYNon-skid tape from ladder to manhole.
TIE OFFA safety lanyard tie-off shall be installed on top of tank from ladder to manhole.
LIGHTS/WIRINGLED Per D.O.T. Specifications. 2 work lights at rear of tank near top.
WARNING BEACON1 amber super LED warning light bar mounted on cab. 1 smaller one mounted at rear of tank.
REAR DUMPlarge chute style discharge at bottom rear of tank to rapidly empty tank on to ground or in temporary portable tank for fire fighting. Must be able to close during full discharge if necessary.
POWER TAKE OFF AND DRIVE LINEPTO to be a “HOT SHIFT” direct drive, mounted to the transmission. Activation shall be from a control located in the cab within easy reach of the driver. A drive line shall be connected from the PTO to the pump. It shall be the proper series and type to meet pump and PTO manufactures specifications.
PTO OVERSPEED PROTECTIONUnit shall have provisions to protect the PTO from over speed.
PUMPOne (1) each Berkeley B3ZRMS 4” x 3” or greater, mounted under chassis.
PUMP INLET PLUMBINGTank to pump plumbing shall be 4" stainless steel. A 4" rubber hose shall be installed from the tank to the pump. Valve shall be installed between tank and pump. An anti-vortex straight blade shall be installed inside of tank at outlet to pump. Should have drafting connection in close proximity to pump as well that is 3 inch with male camlock.
DISCHARGE PLUMBINGDischarge plumbing shall be plumbed to a 3" stainless steel manifold. Manifold shall have Victaulic coupling provisions for easily adding any available pump discharge plumbing option, including spray heads, discharges, and/or monitor. To have a discharge with ball valve in close proximity to pump. This discharge to be 2 inch with 2 inch male camlock. May have adapter with hose bib to satisfy hose bib requirements.
TANK RETURNA 1/4” tank return line with ball valve and check valve shall be located on the discharge side of the pump. This line will allow the pump to “slip” water back into the tank when the pump is running with all discharges and spray heads closed (“dead-heading” the pump).
FRONT SPRAY HEAD PACKAGEto include a left and right front pivotal fan spray head that can be manual adjusted without tools to aim spray. Shall be individually controlled from switches inside cab.
REAR SPRAY HEAD PACKAGEto include a left and right front pivotal fan spray head that can be manual adjusted without tools to aim spray. Shall be individually controlled from switches inside cab.
SIDE SPRAY CURBSIDEAn electrically controlled pivotal fan spray shall be mounted on the curbside of the unit. An air switch in the cab shall activate a valve to open and spray water in a controlled pattern on the right side of the unit.
SIDE SPRAY ROADSIDEAn electrically controlled pivotal fan spray shall be mounted on the roadside of the unit. An air switch in the cab shall activate a valve to open and spray water in a controlled pattern on the left side of the unit.
HOSE BIBGarden style hose bib discharge either at back or above pump.
HOSEREELS1 hose reel mounted on rear of tank with power retract by push of button within 2 feet of hose reel. Plumbing to be 1.5 inch or greater. Hose to be 1 inch to 1.5 inch with adjustable spray nozzle with shut off. Ball valve to shut off hose reel.
LOW POINT DRAINSLow point drains shall be installed in all plumbing and clearly labeled.
HOSE STORAGE TUBEOne hose storage tube on each side of tank to include and hold 1 two inch by 8 feet reinforced vinyl hose with one male and one female 2 inch camlock. Should have hasp to secure hose in tube. Second storage tube to include one 2.5 inch by 8 feet reinforced vinyl hose with 2.5 inch camlock on each end. 1 female 1 male. also to be secured in tube. One adapter with 2.5 inch male camlock on one end and 2 inch female camlock on other end to be stored in toolbox.
TOOLBOXOne (1) each aluminum single door 24 to 36”W x 18”H x 18”D) with stainless steel hardware and lockable latch.
WRENCHSOne (1) each fire hydrant wrench with holder shall be provided
SERVICE/SUPPORTWe need dealer support within 25 miles from the installation. There is a limited amount of manufacturers that have dealer support in the Yakima area. We are often having to run to the dealer for parts and consumable items. Occasionally we have to haul our equipment to the dealer or they come to installation for a service call. We do not have the time or man power to be traveling great distances to get this support. For the reasons mentioned above we ask that consideration be limited to manufacturers that have a dealer with a service and parts department within 25 miles of the Yakima Training Center.
MANUALSOne (1) each operation and maintenance manual(s) in paper format and one (1) each operation and maintenance manual(s) on CD ROM (in PDF format) shall be supplied and shipped with unit; complete with the following.

• Operator & Maintenance Manual

• Calibration Chart (if Applicable)

• Equipment Parts List

• Misc. Vendor Literature / Manuals