J04 Site Design - County Approved.pdf

PDF 5 MB Posted

Attached to
Individual Homeowner Septic System Replacement - Pierce County, WA
Solicitation number
75H70122Q00011
Issued by

View the file

Other files

File Type Posted
J02 Measurement and Payment.pdf PDF
J01 WD20220072 dated 02252022 (Heavy).pdf PDF
J05 Site Aerials.pdf PDF
J03 IHS Technical Provisions.pdf PDF
B01 75H70122Q00011.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Received 12/28/2021

On-Site Sewage Approved for Permit Release

Kristen Farley, RS 12/30/2021

On-Site Sewage Approved for Permit Release

NOTE: SPRINKLER SYSTEM LOCATION SHOWN

ESTIMATED BY HOMEOWNER. CONTRACTOR TO

FIELD VERIFY, PROTECT IN PLACE AND MODIFY AS

NEEDED (IN CONSULTATION WITH HOMEOWNER)

TO ALLOW INSTALLATION OF DRAINFIELD.

On-Site Sewage Approved for Permit Release

Kristen Farley, RS

Permit Conditions: Site not suitable for use of Infiltrator tanks.

On-Site Sewage Approved for Permit Release

On-Site Sewage Approved for Permit Release

1 inch filter

To tankFrom Coil

From Pump

1" water meter

To coil

Headworks

HWN-1-RF

Waste Water Ef"uent | Sewage Ejectors | Grinders

Thermoplastic

SUBMITTAL DATA SHEET

Reinforced Thermoplastic motor bracket and discharge with built-in guide bearing. Sizes range from 1/2 - 1 1/2 HP. 300 series stainless steel top bearing and motor coupling. The 1/2 HP through 1 HP uses composite and 1 1/2 HP uses stainless steel motor. Two wire single phase models include pump, motor, and 10’ “SJOW” lead, 25’, 50’ & 100’ available.

All four inch submersibles are supplied with grounded leads meeting the National Electrical Code (N.E.C.)

speci#cations.

The performance curves on the following page will assist you in choosing the pump that meets your needs.

MODELS | 5 GPM - J Series | 7 GPM - V Series | 10 GPM - K Series | 15 GPM - L Series | 20 GPM - P Series 30 GPM - E Series

NO-LEAD: The weighted average of the wetted surface of this no-lead product contacted by consumable water contains less than one quarter of one percent (0.25%) lead.

A.Y. McDonald considers the information on this assembly drawing correct when published. Item and option availability, including speci#cations, are subject to change without notice.

Submitted by: 10-13

A.Y. McDonald Mfg. Co. Toll Free: 1-800-292-2737 sales@aymcdonald.com P.O. Box 508 Fax: 1-800-832-9296 www.aymcdonald.com Dubuque, IA 52004-0508 Hours: 7:00 a.m. - 5:00 p.m., CST

- Stainless steel pump shell and pump shaft

- Reinforced Thermoplastic diffusers and impellers

- Internal, anti-spin check valve standard

- Thermoplastic intake screen and cable guard

- Powered by NEMA standard composite submersible motors 1/2 - 1 HP.

- 1 1/4” FNPT Discharge

SUBMITTAL INFORMATION

P1 of 2

Model No. HP Material Volt Phase A B Wt.

22050J2AJ 1/2 Plastic 115 1 16.6 9.5 26 22050J2J 1/2 Plastic 230 1 16.6 9.5 26 22075J2J 3/4 Plastic 230 1 20.3 10.7 30 22100J2J 1 Plastic 230 1 22.5 11.8 35

Model No. HP Material Volt Phase A B Wt.

22050V2AJ 1/2 Plastic 115 1 14.3 9.5 25 22050V2J 1/2 Plastic 230 1 14.3 9.5 25 22075V2J 3/4 Plastic 230 1 16.6 10.7 28 22100V2J 1 Plastic 230 1 18.8 11.7 32 22150V2J 1 1/2 Plastic 230 1 24.0 13.6 40

0 1 2 3 4 5 6 7 8 9 10 11 12 13

TO

TA

L H

EA

D

I N

F

EE

T

U.S. GALLONS PER MINUTE

SHUTOFF HEAD

1 1/2 HP - 25 Stages

1 HP - 18 Stages

3/4 HP - 15 Stages

1/2 HP - 12 Stages

J Series - 5 GPM V Series - 7 GPM

0 1 2 3 4 5 6 7 8 9 10 11

TO

TA

L H

EA

D

I N

F

EE

T

U.S. GALLONS PER MINUTE

SHUTOFF HEAD

1/2 HP - 15 Stages

1 HP - 25 Stages

3/4 HP - 20 Stages

A

B

M c D O N A L D

Waste Water Ef"uent | Sewage Ejectors | Grinders

Thermoplastic

SUBMITTAL DATA SHEET

NO-LEAD: The weighted average of the wetted surface of this no-lead product contacted by consumable water contains less than one quarter of one percent (0.25%) lead.

A.Y. McDonald considers the information on this assembly drawing correct when published. Item and option availability, including speci#cations, are subject to change without notice.

Submitted by: 10-13

A.Y. McDonald Mfg. Co. Toll Free: 1-800-292-2737 sales@aymcdonald.com P.O. Box 508 Fax: 1-800-832-9296 www.aymcdonald.com Dubuque, IA 52004-0508 Hours: 7:00 a.m. - 5:00 p.m., CST

P2 of 2

Model No. HP Material Volt Phase A B Wt.

22050K2AJ 1/2 Plastic 115 1 12.3 9.53 23 22050K2J 1/2 Plastic 230 1 12.3 9.53 22 22075K2J 3/4 Plastic 230 1 13.7 10.66 27 22100K2J 1 Plastic 230 1 16.0 11.75 31 22150K2J 1 1/2 Plastic 230 1 19.7 15.12 40

U.S. GALLONS PER MINUTE

TO

TA

L H

EA

D

I N

F

EE

T

SHUTOFF HEAD

0 2 4 6 8 10 12 14 16 18 20 22

1/2 HP 7 Stage

1 1/2 HP 16 Stage

1 HP 12 Stage

3/4 HP 9 Stage

Model No. HP Material Volt Phase A B Wt.

22050L2AJ 1/2 Plastic 115 1 13.55 9.53 23 22050L2J 1/2 Plastic 230 1 13.55 9.53 23 22075L2J 3/4 Plastic 230 1 15.71 10.66 27 22100L2J 1 Plastic 230 1 17.85 11.75 31 22150L2J 1 1/2 Plastic 230 1 21.07 15.12 39

U.S. GALLONS PER MINUTE

TO

TA

L H

EA

D

I N

F

EE

T

0 5 10 15 20 25 30 35

SHUTOFF HEAD

1 1/2 HP 13 STAGES

1 HP 10 STAGES

3/4 HP 8 STAGES

1/2 HP STAGES

K Series - 10 GPM

P Series - 20 GPM

L Series - 15 GPM

E Series - 30 GPM

U.S. GALLONS PER MINUTE

TO

TA

L H

EA

D

I N

F

EE

T

0 5 10 15 20 25 30 35

SHUTOFF HEAD

1 1/2 HP 12 STAGES

1 HP 9 STAGES

3/4 HP 7 STAGES

1/2 HP 5 STAGES

U.S. GALLONS PER MINUTE

TO

TA

L H

EA

D

I N

F

EE

T

0 5 10 15 20 25 30 35 40

SHUTOFF HEAD

3/4 HP 5 STAGES

1/2 HP 4 STAGES

1 1/2 HP 9 STAGES

1 HP 7 STAGES

Model No. HP Material Volt Phase A B Wt.

22050P2AJ 1/2 Plastic 115 1 12.48 9.53 23 22050P2J 1/2 Plastic 230 1 12.48 9.53 23 22075P2J 3/4 Plastic 230 1 14.63 10.66 27 22100P2J 1 Plastic 230 1 16.78 11.75 31 22150P2J 1 1/2 Plastic 230 1 20.00 15.12 41

Model No. HP Material Volt Phase A B Wt.

22050E2AJ 1/2 Plastic 115 1 10.94 9.53 23 22050E2J 1/2 Plastic 230 1 10.94 9.53 23 22075E2J 3/4 Plastic 230 1 12.48 10.66 25 22100E2J 1 Plastic 230 1 14.63 11.75 30 22150E2J 1 1/2 Plastic 230 1 16.78 15.12 39

7 Attach 1 Site Design County Approved
design with sprinkler system drawn over it
7 Attach 1 Site Design County Approved

File details come from the government source that posted it. Updated .