This statement of work describes fence construction projects for the Pocatello Municipal Watershed and Malad Summit Campground. The contractor will purchase materials, remove existing fencing, and construct approximately 6 miles of 4-strand barbed wire fence for the watershed and 0.16 miles for the campground. Specific requirements include line spacing, post installation depths, h-bracing, tensioning of wires, and disposal of waste. The contracting agency is the Department of Agriculture Forest Service Region 4 Intermountain Region. The solicitation number is 1240LT23Q0072 and responses are due by September 11, 2023. The statement of work provides construction specifications and details site access instructions and safety requirements for working on remote forest land.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P a g e | 1
SECTION C--DESCRIPTION/SPECIFICATIONS/STATEMENT OF WORK
C- 1 - Project Description and Location
(a) Description of Work.
Pocatello Municipal Watershed Fence The Contractor will purchase the new fence material, haul the new materials to the fence location, and provide their own material, labor, supervision, equipment, tools, and transportation required to complete the fence project.
This work consists of supplying materials and construction of a 4-strand let-down fence, top 3 strands are barbed wire and bottom wire is smooth (Exhibit 1). Total of 5,702 linear feet or 1.08 miles of 4-strand let-down wire fence. The space interval between t-posts shall be 16 feet at let-down section, the space interval between posts shall be 12 feet at permanent up, and an H brace will be installed approx. every ¼ mile, end of fence, or change of direction. The space interval between wood stay shall be 8 feet with a wood stay attached to steel post for the four wire segments.
Fencing shall be constructed off the ends of existing fence H braces adjacent to the beginning and end of the contracted fence, shown in Exhibit 2. A stretch gate and H brace shall be constructed at the southern end of the fence line attaching to the existing H brace (completing a finished stretch gate). Fence will continue along the delineated route with an estimate of 5 corner braces to the next stretch gate constructed at Wild Horse Divide. The fence shall then continue along the delineated route to the northern end of the fence line with an estimate of at least 1 H brace, or potentially corner brace, based on terrain. A stretch gate and H brace shall be attached to the existing fence H brace at the northern end to complete the final stretch gate.
An estimate of (5) H braces and (6) corner braces will be constructed along the 5,702-foot fence line. H braces will be constructed every ¼ mile. H braces need 2 treated posts dug and a treated cross piece each, 4-6” treated post by 7-8’ long dug 30-36’ in the ground (See Exhibit 2). Construct double H braces (3 posts) for corners. (3) Stretch gates shall be constructed with H braces on either side of the gate (see Exhibit 3), locations will be identified by map.
Approximately (357) 6’ steel t-posts every 16 feet and (714) 2” wood stays every 8 feet with every other one attached to steel t-post for let-down.
Wire spacing measures as follows (See Exhibit 1):
18” between the bottom wire (smooth) and the ground 6” between the lower middle wire (barbed) and bottom wire (smooth) 6” between the two middle wires (both barbed) 10” between the top mire and upper middle wire (both barbed)
Add a wood post for high and low spots.
P a g e | 2
Malad Summit Campground Fence The Contractor will remove the existing fences, haul the old fence materials for disposal, purchase the new fence material, haul the new materials to the campground, provide their own material, labor, supervision, equipment, tools, and transportation, required to complete the fence projects at the job site.
Malad Summit Campground Fence This work consists of removal of existing fence, supply materials and construction of a 4-strand fence enclosures; top 3 strands are barbed wire and bottom wire is smooth. Total of 845 linear feet or 0.16 miles of 4-strand wire fence. The space interval between t-posts shall be 16 feet and an H brace will be installed approx. every ¼ mile. The space interval between wood stay shall be 8 feet with a wood stay attached to steel post for the four wire segments.
(8) H braces will be constructed along the 845-foot fence line. H braces will be constructed every ¼ mile. H braces need 3 treated posts each. 4-6” treated post by 7-8’ long, dug 30-36” in the ground. Construct double H brace for corners. (See Exhibit 2)
Approximately (54) 6’ Steel t-posts every 16 feet, wood stays every 8 feet.
Wire spacing measures as follows (See Exhibit 1):
18” between the bottom wire (smooth) and the ground 6” between the lower middle wire (barbed) and bottom wire (smooth) 6” between the two middle wires (both barbed) 10” between the top mire and upper middle wire (both barbed)
Some brush clearing needed.
Add a wood post for high and low spots.
All line wires shall be dead-ended on gate, corner, angle, and line brace posts. The ends shall be double wrapped around the post, stapled securely, and twisted back on the stretched wire to prevent the post from twisting.
Alignment – The fence line shall be constructed as straight as possible.
(b) Project Location.
Pocatello Municipal Watershed Fence Approximately 12 miles south of Pocatello, ID. Access to the site from Bannock Highway (Mink Creek Rd), continue south for 10 miles. Turn right (North) on Elk Meadows Road, Forest Road 006, for 5 miles to the end of the road. Then take ATV/UTV on the Elk Meadows ATV trail approximately 4 miles north. See attached map for actual project location.
P a g e | 3
Malad Summit Campground Approximately 14 miles north of Malad, ID. Access to the site from Highway 15, take exit 22 (Devil Creek Reservoir). North on Old Highway 191 for 3.5 miles. Turn left on E11000N/Forest Road 041 for another few miles. See attached map for actual project location.
(b) Project Location.
Pocatello Municipal Watershed Fence Approximately 12 miles south of Pocatello, ID. Access to the site from Bannock Highway (Mink Creek Rd), continue south for 10 miles. Turn right (North) on Elk Meadows Road, Forest Road 006, for 5 miles to the end of the road. Then take ATV/UTV on the Elk Meadows ATV trail approximately 4 miles north. See attached map for actual project location.
Malad Summit Campground Approximately 14 miles north of Malad, ID. Access to the site from Highway 15, take exit 22 (Devil Creek Reservoir). North on Old Highway 191 for 3.5 miles. Turn left on E11000N/Forest Road 041 for another few miles. See attached map for actual project location.
(c) Site Visit. (See Section L, FAR Clause 52.236-27). ATV/UTV access is recommended to get the Pocatello Municipal Watershed Fence project location. See attached map for actual project location. Malad Summit Campground fence can be accessed via foot from Forest Road 041. See attached map for actual project location.
(d) Start Work.
The estimated start date for the project is September 11, 2023.
(e) Period of Performance. (See Section F, FAR Clause 52.211-10.)
C- 2 - Government-Furnished Property
No Government property will be furnished to the Contractor for use in the performance of this contract.
C- 3 – Fence Construction Specifications
All products and execution shall be in accordance with the Exhibits 1 through 3, included as an attachment to Section J, and the following specifications:
The Forest Service prefers a 4-wire fence (Pocatello Municipal Watershed Fence and Malad Summit Campground).
Installation of 4-wire fences at Pocatello Municipal Watershed Fence and Malad Summit Campground:
1. Fence line Clearance - Fence line clearance or pathway will be kept within a maximum of 30 feet. Fence line placement may be to one side of the pathway to minimize livestock pressure and will be determined by the COR.
P a g e | 4
2. Alignment – The fence line shall be constructed as straight as possible.
3. Post Spacing, Depth and Height - the tension-cable anchor will be fastened to a permanent fence line H brace. The space interval between posts shall be 16 feet at let-down section; the space interval between post shall be 12 feet at permanent up. An H brace will be installed approx. every ¼ mile. Construction should allow each section between anchor points to be laid down. Let down is to uphill of the fence line and post in the ground. Wooden stays are used to attach wire at each steel post. Wire loops are used to hold the stay to the line structure. All wood line posts shall be set solidly in soil at a minimum depth of 30 inches. Steel posts shall be set at least 2” deeper than the anchor. The gate and brace posts shall be set solidly in soil at a minimum depth of 36 inches.
4. Wire Spacing - Wire spacing measures are as follows:
All line wires shall be dead ended on gate, corner, angle, and line brace posts. The ends shall be double wrapped around the post, stapled securely, and twisted back on the stretched wire to prevent the post from twisting. Barbed wire must be stretched tight with similar tension on all 4 strands. The barbed wire shall not sag or be loose in any areas. Exhibit 1 above shows the correct wired spacing specifications.
5. H Bracing –required on corners or any change of direction (3 posts), on each side of a gate, ends of fence (2 posts) or on straight sections that may exceed ¼ mile in length (2 posts). H-braces shall be vertical, sturdy, dirt packed solid and in straight alignment with the fence on each side. See Exhibit 2 for H Brace and Corner Brace examples.
6. Gates – Wire gate closures shall be 12 feet wide, consist of four strands of barbed wire, four wooden stays evenly spaced on the gate. H braces shall be installed on both sides of the wire gate. Locations will be identified by COR or by map. (Exhibit 3)
7. Top Rail- Top rail shall be constructed in riparian areas. Top rail shall not exceed 42” in height. One rail shall span from one post, over a post and end at the third post. Rail
P a g e | 5 ends are to overlap on the ends with one spike driven through both rail ends. The end of the rails shall be pre-drilled to prevent splitting by the spike.
8. Other - Minor realignment may occur to avoid large rocks or snow deposition zones, while still attempting to keep the fence as straight as possible.
All construction debris shall be removed prior to completion.
C- 4 – Inspection of Worksite
The Contractor acknowledges they have taken the necessary steps to ascertain the nature and location of work and have investigated and satisfied themselves as to the general and local conditions that can affect the work or its cost. Any failure of the Contractor to take the actions described and acknowledged in this paragraph will not relieve the Contractor from the responsibility of estimating properly the difficulty and cost of successfully performing the work, or for proceeding to successfully perform the work without additional expenses to the government.
C- 5 – Recycling and Disposal of Refuse
With the exception of materials specifically indicated or specified to be salvaged for reuse in construction, or turned over to the Government, all refuse, excess or waste materials resulting from construction operations shall become the property of the Contractor and shall be recycled and/or disposed of. All disposals shall be in accordance with federal, state, and local laws and
P a g e | 6 regulations. No disposal, viewing or sale of materials and/or equipment shall be allowed on Government property.
C- 6 – Safety
During the execution of this contract, the Contractor shall conform to the rules and regulations as set forth by OSHA Safety and Health Standards, 29 CFR Part 1926 - Safety and Health Regulations for Construction. Smoking will not be permitted in any building or structure.
C- 7 – Field Work Notice
The project area is located in the Westside Ranger District on the Caribou-Targhee National Forest. The contractor will be working in remote areas and will be exposed to natural conditions including but not limited to, traveling on uneven and rocky terrain, encounters with bears and other wildlife, and inclement weather. The contractor is responsible for ensuring that all employees are trained and have proper safety equipment prior to commencing work in the project area.
C- 8 – Bio-preferred Products
The Contractor must comply with the Farm Security and Rural Investment Act of 2002 (FSRIA), 7 U.S.C. 8102; the Food, Conservation and Energy Act of 2008 (FCEA), 7 U.S.C. 8102; the Federal Acquisition Regulation; Executive Order (EO) 13514, “Federal Leadership in Environmental, Energy and Economic Performance,” dated October 5, 2009; EO 13423, “Strengthening Federal Environmental, Energy, and Transportation Management,” dated January 24, 2007; and Presidential Memorandum, “Driving Innovation and Creating Jobs in Rural America through Biobased and Sustainable Product Procurement,” dated February, 2012 to provide biobased products.
Finding BioPreferred products is simple, using the program’s online catalog. To view the catalog, go to www.biopreferred.gov.
C-9 – Temporary Facilities
(a) STAGING AREA: The Contracting Officer Representative shall arrange the location for exterior stockpiling of materials. The Government will provide adequate staging area as close to the job site as practicable. The Contractor shall be responsible for protecting materials stockpiled against adverse weather, damage, theft, and other risks of loss. The Government assumes no responsibility for material or equipment left in the storage area.
(b) SANITARY FACILITIES:
Pocatello Municipal Watershed Fence:
Toilet facilities will not be provided by the Government at job site.
Malad Summit Campground Fencing:
P a g e | 7
Toilet facilities will be available in the Malad Summit Campground. One will be identified in one of the sites for workers.
P a g e | 8
SECTION E--INSPECTION AND ACCEPTANCE
E- 1 - FAR 52.252-2 Clauses Incorporated by Reference (FEB 1998)
This contract incorporates one or more clauses by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. Also, the full text of a clause may be accessed electronically at this/these address(es):
www.arnet.gov/far/
FEDERAL ACQUISITION REGULATION (48 CFR CHAPTER 1) CLAUSES
52.246-12 Inspection of Construction (AUG 1996)
E- 2 – Pre-Final and Final Inspection
a. Pre-final Inspection: The Government may, at its own discretion, conduct a pre-final inspection prior to the contractor requesting a final inspection. Any discrepancies noted shall be corrected prior to final inspection.
b. Final Inspection: When the work is ready for final inspection, the Contractor shall submit a written request for the final inspection to the duly assigned Contracting Officer’s Representative at least seven (7) days prior to the desired final inspection date. The final inspection will be performed with the Contractor by the appropriate Government personnel. If any discrepancies are noted, they shall be handled in accordance with 52.246-12.
File details come from the government source that posted it. Updated .