DEPARTMENT OF THE AIR FORCE

OKLAHOMA CITY AIR LOGISTICS COMPLEX (OC-ALC)

TINKER AIR FORCE BASE OKLAHOMA

Item Description

MEMORANDUM FOR RECORD

SUBJECT: Item Description, A21-003 Crew Hatch Grate

1. The 565th AMXG is requesting utilization of funds for the purchase of 9 Fabraicated Crew

Hatch Grates.

2. The requested descriptions/specifications are outlined below.

Fabricate nine (9) X201961717 "B-52 Crew Hatch Grate Assembly" per drawing.

The first Grate (as a prototype) will be subjected to functional tests to assess the viability of the item in the production maintenance process. This will take up to twenty-five (25) days. If the grate needs modifications as a results to the review, the engineer will provide for the updating drawing along with a brief description in writing of the needed updates.

The remaining eight (8) shall be delivered no more than sixty (60) days after engineering has validated and verified (val/ver'd) the first.

All shipped and delivered grates shall be fully assembled.

Contractor must have access to all standards or specifications reference in the drawing.

All items fabricated IAW X201961717, must be val/ver'd prior to delivery by an in-house or third party quality assurance specialist (see qualification below). A formal report shall be provided to engineering.

All welders must be AWS Certified Welders (CW).

Company shall have at least 10 years of experience in machining and fixture fabrication.

Quality assurance specialist who has at least 5 years of experience with the ASME

Y14.100 specification including appendices B through E.

3. Point of contact for this memorandum is Kirshten Crenshaw at (405)568-6262 or e-mail at kirshten.crenshaw@us.af.mil.

mailto:kirshten.crenshaw@us.af.mil