DEPARTMENT OF THE AIR FORCE
OKLAHOMA CITY AIR LOGISTICS COMPLEX (OC-ALC)
TINKER AIR FORCE BASE OKLAHOMA
Statement of Requirement / Item Description
76 MXSG is requesting the purchase of the following items: one (1) Miller FILTAIR 8000 Fume Extractor and one (1) Miller FILTAIR Spark Cooler in support of project 21E067. This requirement must meet following specifications:
Fume Extractor – Miller FILTAIR 8000
• Input Power: 460V, 3 Phase, 20HP
• Nominal Airflow Range: 2,500 cfm – 7,000 cfm
• Sound Level: 72 – 75 dBA at 5ft.
• Peak Pulse Cleaning Sound Level: 92.7 dBA at 5ft.
• Dimensions: 37.2in. long x 83.2in. wide x 135in. tall
• Filters: MERV 15 filter rating minimum o Particle Size Range Efficiency:
0.3 micrometers – 1 micrometer: 85 – 95% 1 micrometer – 3 micrometers: 90% 3 micrometers to 10 micrometers: 90% o High Weld Fume Capture Efficiency o Low Pressure Drop
• Particulate bin: 22-gallon minimum
• 20in. Diameter Inlet
• Air Inlet Location: Top of machine
• Integrated electrical controls with 24 VDC motor start/stop feedback relay o Must be able to control motor controls, filter differential, and pulse cleaning system
• Filter Access Door
• Indoor Unit
• All welded construction
Spark Cooler – Miller FILTAIR model 300958008
• 20in. FILTAIR Spark Cooler, model 300958008
• Must be able to cool and suppress all sparks
• Fully assembled & ready for install
• All welded construction