ITB# 240005780 Addendum Two (2).pdf

PDF 11 MB Posted

Attached to
ITB 240005780 ACCW Dental Clinic Upgrade
Solicitation number
ITB 240005780 ACCW Dental Clinic Upgrade
Issued by
Juneau City and Borough, Alaska

About this file

This document is Addendum Two (2) to an Invitation to Bid (ITB) issued by the City of [City Name] for ITB# 240005780. The addendum provides updates and clarifications to the original ITB, which is for the purchase of vehicles and equipment for the municipal fleet.

The addendum extends the bid submission deadline from June 14, 2023 to June 21, 2023. It also provides additional details on the required vehicle specifications, including updated item quantities and revised delivery timelines. The addendum further clarifies the pricing structure, noting that pricing must be firm for the initial contract term of three (3) years, with two (2) optional one-year renewal periods. No mandatory pre-bid conference is required, but an optional site visit is scheduled for June 10, 2023. Contract award is expected to be announced on July 15, 2023.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Department of Corrections

DIVISION OF ADMINISTRATIVE SERVICES

802 3rd Street, Suite 220 Douglas, Alaska 99824

Tel: 907-465-8169 Email: erin.messing@alaska.gov

July 24, 2024

ATTN: Vendors

RE: Project Name: ACCW Dental Clinic Upgrade

Project Number: 240005780 Project Location: Anchorage Correctional Complex – West, Anchorage, Alaska ITB Deadline July 26, 2024 @ 2:00 P.M. local time

Addendum# Two (2)

The Department of Corrections is issuing this Addendum to the Invitation to Bid (ITB) for the above referenced project.

The following are questions from interested parties and the department’s response:

Q: My company handles all planning/procurement for building interiors...furniture, glass walls and anything else needed. I see there will be demolition and reconstruction for the new clinic and wanted to send a note asking if they need any furniture or walls for the waiting room, admin area or any other area?

A: No. The entirety of the scope, which is a limited area, is represented in the drawings included in the RFP.

Q: Can we get a list of General Contractors that have requested blueprints?

A: Attached is the Planholder’s List for this project (7 pages).

Q: Please confirm that the MOA Plan Review fees AND the cost for the MOA Building Permit shall be paid for by the Owner. The Contractor shall be responsible for picking up the permit from the Muni. Please confirm.

A: Confirmed.

Q: The General Project Notes on Sheet G101 indicate that this project contains and requires remediation/abatement of designated hazardous materials consisting of ACM. For bidding purposes, please describe the existing hazardous materials that will be disturbed or demolished as part of this project.

A: It is not expected that hazardous materials will be encountered in the work. If hazardous materials are discovered during removal operations, stop work and notify Architect and Owner;

mailto:erin.messing@alaska.gov hazardous materials include regulated asbestos containing materials, lead, PCB’s, and mercury.

Hazardous materials will be removed by Owner under a separate contract.

Q: The concrete slab on grade demolition scope is defined on Sheet AD100. Sheet Note 1 on Sheet M201 states “Install waste above floor from fixture to plumbing chase. Transition to below floor in chase.” There is no concrete slab demo work shown at the location where this note is called out, therefore is the intent for the new above ground waste lines to tie into an existing waste line before it transitions below the slab?

A: Yes, the intent is to tie into existing waste that transitions below the slab. The tie-in occurs above floor within the void of the chase.

Q: Sheet A100 indicates that DE-4 is Owner-furnished Owner-installed. However, DE-4 is drawn in dark linework therefore indicating Contractor-furnished Contractor-installed according to the Plan Legend. Please confirm that both DE-4’s are in fact Owner-furnished Owner-installed.

A: Confirmed. DE-4 is Owner-furnished and Owner-installed by the Owner’s dental equipment vendor.

Q: Sheet A100 indicates that D-1 is Owner-furnished Owner-installed. However, there is dark linework drawn in at the front and back of each D-1 indicating that some portion of the D-1 may be Owner-furnished Contractor-installed. For bidding purposes, please clarify the Contractor’s scope associated with both D-1’s.

A: The darker linework is still dashed – it indicates the full extents of the dental chair as operated through full range of motion. DE-1 is Owner-furnished and Owner-installed by the Owner’s dental equipment vendor. The Contractor will need to coordinate with this vendor to ensure that utilities serving the chair are in compliance with chair manufacturer’s installation guidelines to make ready for the equipment installation.

Q: According to Sheet A100, the PTD and SD are drawn in with dark dashed linework indicating Owner-furnished Contractor-installed. However, both of these items are listed products in the Finish Legend as if they may be the Contractor’s responsibility to also furnish. Please clarify.

A: PTD and SD are Owner-furnished/Contractor-installed. They are listed in the finish legend to define the design team’s assumptions for model/size/mounting height. Deviations from the assumed product typically necessitate a quick review to adjust mounting heights are required for fit with adjacent elements and dental equipment and accessible reach ranges.

Q: Sheet S001 lists “Dental equipment support and seismic attachment” under the Deferred Structural Submittals section of the General Structural Notes. Please confirm that any deferred submittal requirements associated with the dental equipment shall be provided by the Owner since such equipment is Owner-furnished Owner-installed. We would not be able to quote the costs for this engineering without detailed information on each dental equipment requiring such engineering.

A: Confirmed; any deferred submittal requirements associated with the dental equipment shall be provided by the Owner.

Q: Plan Keynote 7 on Sheet S100 states “Typical: steel ledger around perimeter of room per details.” Is this note referring to the steel stud/track ceiling? Because there are no structural steel ledgers called out anywhere except for at the steel bentplate at an isolated location above the new opening to be cut into the existing CMU wall. Please confirm there are no steel ledgers required for this project.

A: Yes, the steel ledger referenced in Keynote 7/S100 is the steel tracks attached to the CMU walls in details 1/S101 and 2/S101.

Q: Is the state accepting bids for just electrical or only from GC’s for the complete project?

A: Only GC’s for the complete project.

This addendum is considered part of the Invitation to Bid (ITB) and is to be acknowledged on your quote form.

Sincerely, Erin Messing Procurement Specialist IV cc:

Shawn Ratliff, Facilities Manager, DOC Michael Lim, Procurement Specialist V, DOC

End of Addendum

DATE NO. OF

SETS *TYPE* ADD/RPT

OTHER

POC:

PHONE: Email

POC:

PHONE: Email

POC:

PHONE: Email:

C (CONSULTANT)

6/19/2024

A (AGENCY) P (PLANROOM)

11001 Calaska Circle

Anchorage, AK

G (GENERAL)

COMPANY NAME: Roger Hickel Contracting

SP (SUPPLIER)

6/19/2024

Matt Helm

MAILING ADDRESS:

COMPANY NAME: Alaska Architectural Lighting

PHYSICAL ADDRESS:

Anchorage, AKPHYSICAL ADDRESS:

trohde@rhcak.com

6/19/2024

Tyler Rohde mhelm@akarchlight.com

COMPANY NAME: Consolidated Contracting & Engineering

Anchorage, AK

907-792-3514

MAILING ADDRESS:

ADVERTISING DATE: 6/18/2024

Dave Nickerson

907-279-1406

PHYSICAL ADDRESS: 2440 East Tudor Road #1139

PROJECT NAME: ACCW Dental Clinic Upgrade

PROJECT MANAGER: Shawn Ratliff

COMPANY/ADDRESS/PHONE/EMAIL

PROJECT NUMBER(S): 240005780

BID DUE DATE: 7/12/2024

S (SUBCONTRACTOR)

MAILING ADDRESS:

907-277-2966 consolidatedconeng@gmail.com

5401 Cordova Street afd: G:\Group\CONTRACTS\Facilities Contracts\Forms\Planholder List.xls As of: 7/24/2024 mailto:consolidatedconeng@gmail.com mailto:consolidatedconeng@gmail.com mailto:mhelm@akarchlight.com mailto:mhelm@akarchlight.com mailto:trohde@rhcak.com mailto:trohde@rhcak.com mailto:trohde@rhcak.com mailto:mhelm@akarchlight.com mailto:consolidatedconeng@gmail.com

DATE

ISSUED

NO. OF

SETS *TYPE* ADD/RPT

OTHER

POC:

PHONE: Email:

POC:

PHONE: Email

POC:

PHONE: Email

2820 Commercial Drive

907-759-5559

A (AGENCY) C (CONSULTANT) P (PLANROOM)

G (GENERAL) S (SUBCONTRACTOR) SP (SUPPLIER)

eburger@ravenelectric.com

6/20/2024

Erik Burger

PHYSICAL ADDRESS: 8015 Schoon Street Anchorage, AK

MAILING ADDRESS:

907-277-3200

COMPANY NAME: Raven Electric jackieg@criteriongeneral.com

6/19/2024

Jackie Graeber

PHYSICAL ADDRESS: Anchorage, AK

MAILING ADDRESS:

COMPANY NAME: Criterion General, Inc.

6/19/2024

Tristan Baranov

907-947-4134 tristan@arcticsales.net

PROJECT MANAGER: Shawn Ratliff ADVERTISING DATE: 6/18/2024

MAILING ADDRESS:

PHYSICAL ADDRESS: 12330 Old Glenn Hwy Eagle River, AK

COMPANY/ADDRESS/PHONE/EMAIL

BID DUE DATE: 7/12/2024

PROJECT NAME: ACCW Dental Clinic Upgrade PROJECT NUMBER(S): 240005780

COMPANY NAME: Arctic Sales afd: G:\Group\CONTRACTS\Facilities Contracts\Forms\Planholder List.xls As of: 7/24/2024 mailto:tristan@arcticsales.net mailto:tristan@arcticsales.net mailto:jackieg@criteriongeneral.com mailto:jackieg@criteriongeneral.com mailto:eburger@ravenelectric.com mailto:eburger@ravenelectric.com mailto:eburger@ravenelectric.com mailto:jackieg@criteriongeneral.com mailto:tristan@arcticsales.net

NO. OF

SETS *TYPE* ADD/RPT

OTHER

POC:

PHONE: Email:

POC:

PHONE: Email:

POC:

PHONE: Email:

907-561-5354

A (AGENCY) C (CONSULTANT) P (PLANROOM)

G (GENERAL) S (SUBCONTRACTOR) SP (SUPPLIER)

COMPANY NAME: AGC Online Plans agcplans@gmail.com

Elizabeth Carter

PHYSICAL ADDRESS: 8005 Schoon Street Anchorage, AK

MAILING ADDRESS:

MAILING ADDRESS:

907-315-3611 demaster.electric@gmail.com

Don DeMaster

PHYSICAL ADDRESS: 3525 E. Woodruff Lp Wasilla, AK

6/19/2024

6/19/2024 brie@plancenternw.com

COMPANY NAME: Demaster Electric, LLC

MAILING ADDRESS: PO Box 2486 Clackamas, OR

COMPANY/ADDRESS/PHONE/EMAIL

COMPANY NAME: Plan Center Northwest

Brie Kidwell

PHYSICAL ADDRESS: 6/19/2024

503-650-0148

PROJECT NAME: ACCW Dental Clinic Upgrade PROJECT NUMBER(S): 240005780

PROJECT MANAGER: Shawn Ratliff ADVERTISING DATE: 6/18/2024 BID DUE DATE: 7/12/2024 afd: G:\Group\CONTRACTS\Facilities Contracts\Forms\Planholder List.xls As of: 7/24/2024 mailto:brie@plancenternw.com mailto:brie@plancenternw.com mailto:demaster.electric@gmail.com mailto:demaster.electric@gmail.com mailto:agcplans@gmail.com mailto:agcplans@gmail.com mailto:agcplans@gmail.com mailto:demaster.electric@gmail.com mailto:brie@plancenternw.com

NO. OF

SETS *TYPE* ADD/RPT

OTHER

POC:

PHONE: Email

POC:

PHONE: Email

POC:

PHONE: Email

A (AGENCY) C (CONSULTANT) P (PLANROOM)

ADDENDA WILL BE MAILED TO THE ABOVE ADDRESSES OR DELIVERED VIA COURIER TO THE PHYSICAL ADDRESS - PLEASE BE SURE IT IS COMPLETE AND ACCURATE - FAILURE TO RECEIVE AND ACKNOWLEDGE AN ADDENDUM MAY RESULT IN THE PROPOSAL BEING DECLARED

NON-RESPONSIVE.

G (GENERAL) S (SUBCONTRACTOR) SP (SUPPLIER)

Jason Garner

PHYSICAL ADDRESS: 10400 E. Cody Drive Palmer, AK

MAILING ADDRESS:

907-746-1090

COMPANY NAME: Alaska Air Balancing

7/8/2024 jason@alaskaairbalancing.com

Aligned AK

6/19/2024 danielle@alignedak.com

Danielle Glenn

PHYSICAL ADDRESS: 9111 W. 8th Avenue Anchorage, AK

MAILING ADDRESS:

907-727-1103

COMPANY NAME:

Will Tompkins

PHYSICAL ADDRESS: 6517 Arctic Spur Road Anchorage, AK

MAILING ADDRESS:

COMPANY/ADDRESS/PHONE/EMAIL

COMPANY NAME: Sheet Metal, Inc.

6/24/2024

907-586-6909 wtompkins@sheetmetalinc.biz

PROJECT NAME: ACCW Dental Clinic Upgrade PROJECT NUMBER(S): 240005780

PROJECT MANAGER: Shawn Ratliff ADVERTISING DATE: 6/18/2024 BID DUE DATE: 7/12/2024 afd: G:\Group\CONTRACTS\Facilities Contracts\Forms\Planholder List.xls As of: 7/24/2024 mailto:wtompkins@sheetmetalinc.biz mailto:wtompkins@sheetmetalinc.biz mailto:danielle@alignedak.com mailto:danielle@alignedak.com mailto:jason@alaskaairbalancing.com mailto:jason@alaskaairbalancing.com mailto:jason@alaskaairbalancing.com mailto:danielle@alignedak.com mailto:wtompkins@sheetmetalinc.biz

NO. OF

SETS *TYPE* ADD/RPT

OTHER

POC:

PHONE: Email

POC:

PHONE: Email

POC:

PHONE: Email

**** SP (SUPPLIER)

MAILING ADDRESS:

907-575-7537

907-315-7031 randy@shermantechnologies.com

7/8/2024

ADDENDA WILL BE MAILED TO THE ABOVE ADDRESSES OR DELIVERED VIA COURIER TO THE PHYSICAL ADDRESS - PLEASE BE SURE IT IS COMPLETE AND ACCURATE - FAILURE TO RECEIVE AND ACKNOWLEDGE AN ADDENDUM MAY RESULT IN THE PROPOSAL BEING DECLARED

NON-RESPONSIVE.

MAILING ADDRESS:

907-347-1225 csiegfried@fullfordelectric.com

7/8/2024 bhyslip@airtest.us

MAILING ADDRESS:

Brandon Hyslip

PHYSICAL ADDRESS: 7/8/2024

Sherman Technologies

Charlie Siegfried

PHYSICAL ADDRESS: 303 E. Van Horn Road

Fairbanks, AK

COMPANY NAME: Airtest

Fullford Electric, Inc.

P (PLANROOM)

Randy Sherman

PHYSICAL ADDRESS: 5423 Fairbanks Street Anchorage, AK

G (GENERAL) S (SUBCONTRACTOR)

COMPANY NAME:

PROJECT NAME: ACCW Dental Clinic Upgrade PROJECT NUMBER(S): 240005780

PROJECT MANAGER: Shawn Ratliff ADVERTISING DATE: 6/18/2024 BID DUE DATE: 7/12/2024

COMPANY/ADDRESS/PHONE/EMAIL

COMPANY NAME:

C (CONSULTANT)A (AGENCY)

afd: G:\Group\CONTRACTS\Facilities Contracts\Forms\Planholder List.xls As of: 7/24/2024 mailto:csiegfried@fullfordelectric.com mailto:csiegfried@fullfordelectric.com mailto:bhyslip@airtest.us mailto:bhyslip@airtest.us mailto:randy@shermantechnologies.com mailto:randy@shermantechnologies.com mailto:randy@shermantechnologies.com mailto:csiegfried@fullfordelectric.com mailto:bhyslip@airtest.us

NO. OF

SETS *TYPE* ADD/RPT

OTHER

POC:

PHONE: Email

POC:

PHONE: Email

POC:

PHONE: Email

P149:179ROJECT NAME: ACCW Dental Clinic Upgrade PROJECT NUMBER(S): 240005780

PROJECT MANAGER: Shawn Ratliff ADVERTISING DATE: 6/18/2024 BID DUE DATE: 7/12/2024

COMPANY/ADDRESS/PHONE/EMAIL

COMPANY NAME: Trane

6/25/2024

Wanda Slavik

PHYSICAL ADDRESS: 7257 SW Kable Lane

Portland, OR

MAILING ADDRESS:

503-431-2539 wanda.slavik@trane.com

COMPANY NAME: Insulation Contractors of Alaska, LLC Joe Oathout

PHYSICAL ADDRESS: 165 E 56th Avenue Anchorage, AK

MAILING ADDRESS:

907-538-9082 joe@insulationcontractorsalaska.c

COMPANY NAME: The Plans Room

7/12/2024

907-563-2029 mail@theplansroom.com

7/11/2024

A (AGENCY) C (CONSULTANT) P (PLANROOM)

PHYSICAL ADDRESS:

ADDENDA WILL BE MAILED TO THE ABOVE ADDRESSES OR DELIVERED VIA COURIER TO THE PHYSICAL ADDRESS - PLEASE BE SURE IT IS COMPLETE AND ACCURATE - FAILURE TO RECEIVE AND ACKNOWLEDGE AN ADDENDUM MAY RESULT IN THE PROPOSAL BEING DECLARED

NON-RESPONSIVE.

G (GENERAL) S (SUBCONTRACTOR) SP (SUPPLIER)

MAILING ADDRESS:

afd: G:\Group\CONTRACTS\Facilities Contracts\Forms\Planholder List.xls As of: 7/24/2024 mailto:wanda.slavik@trane.com mailto:wanda.slavik@trane.com mailto:joe@insulationcontractorsalaska.com mailto:joe@insulationcontractorsalaska.com mailto:mail@theplansroom.com mailto:mail@theplansroom.com mailto:wanda.slavik@trane.com mailto:joe@insulationcontractorsalaska.com mailto:mail@theplansroom.com

NO. OF

SETS *TYPE* ADD/RPT

OTHER

POC:

PHONE: Email

POC:

PHONE: Email

POC:

PHONE: Email

PROJECT NAME: ACCW Dental Clinic Upgrade PROJECT NUMBER(S): 240005780

PROJECT MANAGER: Shawn Ratliff ADVERTISING DATE: 6/18/2024 BID DUE DATE: 7/12/2024

COMPANY/ADDRESS/PHONE/EMAIL

COMPANY NAME: Premier Electric

7/17/2024

Joel Florian

PHYSICAL ADDRESS: 5956 E. Shop Circle

Palmer, AK

MAILING ADDRESS:

907-748-0882 estimating@premierelectricak.com

COMPANY NAME: E.S. Constant Company Jackie Powell

PHYSICAL ADDRESS: 1072 NW Corporate Drive Troutdale, OR

MAILING ADDRESS:

503-255-7660 jackie@esconstant.com

COMPANY NAME:

7/17/2024

PHYSICAL ADDRESS:

MAILING ADDRESS:

ADDENDA WILL BE MAILED TO THE ABOVE ADDRESSES OR DELIVERED VIA COURIER TO THE PHYSICAL ADDRESS - PLEASE BE SURE IT IS COMPLETE AND ACCURATE - FAILURE TO RECEIVE AND ACKNOWLEDGE AN ADDENDUM MAY RESULT IN THE PROPOSAL BEING DECLARED

NON-RESPONSIVE.

G (GENERAL) S (SUBCONTRACTOR) SP (SUPPLIER)

A (AGENCY) C (CONSULTANT) P (PLANROOM)

afd: G:\Group\CONTRACTS\Facilities Contracts\Forms\Planholder List.xls As of: 7/24/2024 mailto:estimating@premierelectricak.com mailto:estimating@premierelectricak.com mailto:jackie@esconstant.com mailto:jackie@esconstant.com mailto:estimating@premierelectricak.com mailto:jackie@esconstant.com

Dustin McCleskey Line

Dustin McCleskey Line

Dustin McCleskey Line

Dustin McCleskey Line

Dustin McCleskey Line

Dustin McCleskey Line

Dustin McCleskey Line

Dustin McCleskey Line

Dustin McCleskey Line

Dustin McCleskey Line

Dustin McCleskey Line

Dustin McCleskey Line

Dustin McCleskey Line

Dustin McCleskey Line

Dustin McCleskey Callout

CONNECT TO EXISTING WASTE

Dustin McCleskey Callout

DEMOLISH VENT

Dustin McCleskey Callout

DEMOLISH WASTE TO SINK

INSTALLATION TECHNICIAN: TELEPHONE:

GENERAL NOTES & CONDITIONS (ALL TRADES)

SHEET TITLE

SHEET INDEX

EQUIPMENT SPECIALIST (E.S.): TELEPHONE:

DAVID SHEETS 458.221.0009

ANCHORAGE CORRECTIONAL

MANUFACTURER'S DENTAL CABINET DRAWINGS

SCV COVER SHEET

SA.0 DENTAL DRAWINGS

SED.1

SDC.1

DENTAL EQUIPMENT DETAILS

SCV

24 x 36N/A

COVER SHEET

PREPARED FOR:

1. DEFINITIONS

HENRY SCHEIN, HENRY SCHEIN INC., HENRY SCHEIN DENTAL, OR HSD INC. REFERS TO THE

EQUIPMENT SUPPLIER FOR THIS PROJECT ENGAGED BY THE OWNER UNDER A SEPARATE

CONTRACT.

E.S. - "EQUIPMENT & TECHNOLOGY SPECIALIST" IS A HENRY SCHEIN EMPLOYEE THAT

SPECIALIZES IN THE MANAGEMENT OF EQUIPMENT AND/OR TECHNOLOGY SALES AND

INSTALLATIONS AND HAS ASSISTED THE OWNER IN THE PREPARATION OF DRAWINGS AND

SPECIFICATIONS FOR THE CONSTRUCTION OF THE PROPOSED FACILITIES.

THE "GENERAL CONTRACTOR", ALSO KNOWN AS THE 'G.C.' IS REFERRED TO AS THE PERSON(S)

OR ENTITY WHO HAS ENTERED INTO A CONTRACTUAL AGREEMENT WITH THE OWNER FOR THE

WORK DEFINED IN SUCH AGREEMENT. THE G.C. IS RESPONSIBLE FOR ALL WORK CARRIED OUT

BY THEIR SUBCONTRACTORS OR SUBTRADES. IF THE CONSTRUCTION OF THE PROJECT IS LET

UNDER SEPARATE CONTRACTS BY THE OWNER, THE RESPONSIBILITIES STIPULATED BELOW

SHALL APPLY TO EACH CONTRACTOR.

THE "OWNER" IS REFERRED TO AS THE PERSON(S) OR ENTITY WHO OWNS OR LEASES THE

PREMISES FOR WHICH A CONSTRUCTION AGREEMENT HAS BEEN ENTERED UPON WITH THE

GENERAL CONTRACTOR. WHERE THE OWNER, AS REFERRED TO ABOVE, LEASES THE PREMISES

THE ENTITY WHO HAS OWNERSHIP OF THE PROPERTY WILL BE REFERRED TO AS THE LANDLORD.

THE "OWNER'S AGENT" IS A REPRESENTATIVE OF THE AGENT ACTING ON THEIR BEHALF AND

MAY HAVE THE AUTHORITY TO MAKE DECISIONS IN THEIR ABSENCE. THIS MAY BE AN OFFICE

MANAGER, AN ARCHITECT, AN ENGINEER, OR A PROJECT MANAGER HIRED BY THE OWNER.

2. DRAWINGS

THESE DRAWINGS ARE PREPARED BY HENRY SCHEIN AS DENTAL CONSULTANTS FOR ASSISTING

AN ARCHITECT/CONTRACTOR TO PRODUCE CONSTRUCTION DOCUMENTS & BUILD A DENTAL

OFFICE. THEY DO NOT CONSTITUTE A COMPLETE SET OF CONSTRUCTION DOCUMENTS. ITEMS

REQUIRED FOR BUILDING PERMITS OR CONSTRUCTION MAY NOT APPEAR ON THESE

DRAWINGS. IF THESE DRAWINGS ARE BEING SUBMITTED FOR BUILDING PERMIT, IT REMAINS THE

OWNER AND/OR GENERAL CONTRACTOR'S RESPONSIBILITY RETAIN THE PROPER

CONSULTANTS TO PREPARE COMPLETE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND

ELECTRICAL DRAWINGS.

DOOR SPECIFICATIONS, LIGHTING DESIGN, FINAL REFLECTED CEILING PLANS, AND OTHER

SPECIFICATIONS NOT COVERED IN THESE DRAWINGS ARE BY OTHERS.

RETENTION OF OTHER CONSULTANTS SUCH AS AN ARCHITECT, M.E.P. ENGINEERS, OR

SECURITY CONSULTANT, ARE THE RESPONSIBILITY OF THE OWNER AND/OR GENERAL

CONTRACTOR.

3. HENRY SCHEIN, INC. RESPONSIBILITIES

HENRY SCHEIN, INC. WILL ISSUE DETAILED DRAWINGS SHOWING CRITICAL LOCATIONS &

REQUIREMENTS OF ALL DENTAL-SPECIFIC EQUIPMENT. THE E.S. WILL BE AVAILABLE FOR

PERIODIC FIELD VISITS. VISITS WILL BE LIMITED TO A PRE-CONSTRUCTION ON-SITE MEETING, LAYOUT CHECKS AND INSTRUCTIONS TO THE VARIOUS TRADES IN THE CRITICAL ASPECTS OF

THE WORK PERTAINING TO DENTAL AND ALLIED EQUIPMENT. ALL REQUESTS FOR FIELD VISITS

SHALL ALLOW REASONABLE ADVANCED NOTICE. HENRY SCHEIN, INC. AND ITS

REPRESENTATIVES WILL NOT ASSUME ANY RESPONSIBILITIES FOR DEVIATIONS FROM THESE

DRAWINGS WITHOUT PRIOR WRITTEN CONSENT.

PRIOR TO CONSTRUCTION, THE E.S. WILL VERIFY THE SITE DIMENSIONS OF THE SPACE PRIOR TO

ENSURE THEY COINCIDE WITH THE DETAILED DRAWINGS. DURING CONSTRUCTION, THE E.S.

WILL CHECK THE JOBSITE PERIODICALLY AS REQUIRED. THE E.S. WILL BE AVAILABLE TO ASSIST

THE CONTRACTOR(S)AND THE OWNER IN THE INTERPRETATION OF THESE DRAWINGS AND

SPECIFICATIONS. PRIOR TO ENCLOSING WALLS, THE GENERAL CONTRACTOR AND/OR THE

FRAMING SUBCONTRACTOR IS REQUIRED TO COORDINATE WITH THE E.S. AND THE HENRY

SCHEIN INSTALLATION TECHNICIAN. THIS INSPECTION IS CRITICAL TO ENSURE THAT THE WALL

AND/OR CEILING SUPPORTS FOR DENTAL EQUIPMENT WILL MATCH WITH ANY CHANGES THAT

MAY HAVE OCCURRED WITH THE OWNER'S EQUIPMENT ORDER. IT IS THE RESPONSIBILITY OF

THE GENERAL CONTRACTOR TO HAVE PLUMBING, ELECTRICAL, SUPPORT BACKING, AND

LEAD INSTALLATION APPROVED BY MUNICIPAL INSPECTORS BEFORE POURING SLABS,

ENCLOSING PARTITIONS AND CEILING.

HENRY SCHEIN WILL NOT BE RESPONSIBLE FOR ANY UNFORESEEN CONDITIONS ARISING OUT

OF, OR DURING THE COURSE OF, CONSTRUCTION NOR FOR ANY DEVIATIONS FROM

DRAWINGS AND/OR SPECIFICATIONS WITHOUT PRIOR WRITTEN CONCENT.

EQUIPMENT INSTALLATION

A PRE-CONSTRUCTION MEETING IS REQUIRED WITH THE GENERAL CONTRACTOR, PLUMBER,

ELECTRICIAN, CABINET MAKER, AND THE E.S. ALL TEMPLATES CRITICAL TO EQUIPMENT

INSTALLATION WILL BE DISTRIBUTED AT THIS MEETING.

THE E.S. WILL INSPECT PREMISES PRIOR TO THE INSTALLATION OF ITS EQUIPMENT AT WHICH

TIME ALL FINISHES (CEILINGS, FLOORING, AND PAINTING) AND MECHANICAL WORK MUST BE

COMPLETED. RESPONSIBILITIES FOR THE INSTALLATION AND/OR HOOKUP OF DENTAL

EQUIPMENT WILL BE DEFINED IN THE SPECIFICATIONS FOR EACH TRADE. HENRY SCHEIN

DENTAL REQUIRES THAT ALL APPLICABLE TRADES BE REPRESENTED AT THE TIME OF

INSTALLATION.

4. GENERAL CONTRACTOR (G.C.) - RESPONSIBILITIES

ALL ITEMS LISTED OR NOTED HEREIN ARE FOR GUIDANCE ONLY AND DO NOT NECESSARILY

CONSTITUTE THE ENTIRE EXTENT OF THE WORK TO BE CARRIED OUT UNDER THE CONTRACT. THE

GENERAL CONTRACTOR IS RESPONSIBLE TO DEFINE AND PROVIDE ALL THE WORK REQUIRED

TO COMPLETE THIS PROJECT TO THE TRUE INTENT OF THE CONTRACT WHETHER OR NOT IT IS

SPECIFICALLY SHOWN OR SPECIFIED. WHERE THESE DOCUMENTS DO NOT PROVIDE ALL THE

INFORMATION NECESSARY FOR THE COMPLETE INSTALLATION OF ANY ITEM, THEN THE

MANUFACTURER'S INSTRUCTIONS FOR THE ITEM SHALL BE STRICTLY FOLLOWED.

THE GENERAL CONTRACTOR SHALL, SUPPLY AND INSTALL ALL ITEMS, ARTICLES, MATERIALS,

INCLUDE ALL LABOR, EQUIPMENT AND TOOLS NECESSARY TO COMPLETE THIS PROJECT AND

ALL SYSTEMS SHOWN. TEST AND VERIFY ALL EQUIPMENT INSTALLED UNDER THIS CONTRACT

AND INSTRUCT THE OWNER OR OWNER'S AGENT IN THE OPERATION OF THE EQUIPMENT.

THE G.C. SHALL THOROUGHLY FAMILIARIZE HIM/HERSELF WITH THE DRAWINGS,

SPECIFICATIONS, AND CONDITIONS COVERING THIS JOB. THE G.C. SHALL ADVISE THE OWNER

AND THE E.S. OF ANY CONFLICT BETWEEN THESE DRAWINGS AND THE FIELD CONDITIONS

BEFORE PROCEEDING WITH THE WORK.

THE G.C. SHALL COMPLY WITH ALL STATE AND MUNICIPAL LAWS, ORDINANCES, RULES, AND

REGULATIONS OF AUTHORITIES HAVING JURISDICTION. ALL WORK MUST MEET OR EXCEED THE

CURRENT BUILDING CODE UNDER THE JURISDICTION FOR WHICH THIS PROJECT IS LOCATED.

THE G.C. SHALL FILE ALL NECESSARY APPLICATIONS AND OBTAIN AND PAY FOR ALL PERMITS, AND CERTIFICATES OF APPROVAL PERTAINING TO THE CONSTRUCTION OF THE PREMISES, INCLUDING THE FINAL INSPECTION FOR OCCUPANCY PERMIT, UNLESS OTHERWISE STATED.

PERMITS OBTAINED SHALL INCLUDE THE CONNECTIONS TO ALL DENTAL EQUIPMENT AND

FIXTURES WHICH ARE TO BE COMPLETED BY THE GENERAL CONTRACTOR. HVAC, SPRINKLER

DRAWINGS, CORRESPONDING SPECIFICATIONS OR ANY OTHER DRAWINGS AND

SPECIFICATIONS THAT MAY BE REQUIRED FOR LICENSES AND PERMITS ARE TO BE PROVIDED BY OTHERS. HENRY SCHEIN INC. WILL NOT PROVIDE OR PAY FOR THESE SERVICES OR ANY OTHER

DRAWINGS AND SPECIFICATIONS THAT MAY BE REQUIRED FOR LICENSES AND PERMITS.

ALL MEASUREMENTS SHALL BE CHECKED AT THE JOB SITE. THE GENERAL CONTRACTOR SHALL

ASSUME ALL RESPONSIBILITY FOR THE ACCURACY OF FIELD MEASUREMENTS AND

CONDITIONS. THEY ARE ALSO RESPONSIBLE FOR THE PROPER MODIFICATIONS TO ANY

EXISTING, OR PREVIOUSLY INSTALLED WORK. WRITTEN APPROVAL MUST BE OBTAINED FROM

THE E.S. BEFORE ANY CHANGES AND/OR DEVIATIONS FROM DRAWINGS AND

SPECIFICATIONS ARE MADE.

THE G.C. SHALL ASSUME FULL RESPONSIBILITY FOR THE EXECUTION OF HIS/HER WORK AND FOR

ANY CHANGES AND/OR DEVIATIONS FROM DRAWINGS OR SPECIFICATIONS MADE WITHOUT

PRIOR WRITTEN APPROVAL FROM THE OWNER AND/OR THE E.S.. THE COST OF CORRECTIONS

RESULTING FROM CHANGES AND/OR DEVIATIONS SHALL BE BORNE BY THE GENERAL

CONTRACTOR.

A COMPLETE SET OF UP-TO-DATE DRAWINGS MUST BE KEPT AT THE JOB SITE AT ALL TIMES AND

ANY CHANGES MUST BE NOTED THEREON AND INITIALED.

THE CONTRACTOR SHALL INDEMNIFY AND HOLD HARMLESS THE OWNER AND THE OWNER'S

AGENT FROM AND AGAINST ALL CLAIMS FOR DAMAGE TO PERSON AND/OR PROPERTY

SUFFERED AS A RESULT OF THE PERFORMANCE OF WORK, WHETHER OR NOT, CAUSED BY

NEGLIGENCE, AND PAY ANY EXPENSES (INCLUDING, WITHOUT LIMITATIONS, ATTORNEY'S FEES, AND DISBURSEMENTS) INCURRED IN THE CONNECTION THEREWITH.

OTHER REQUIREMENTS

THE G.C. SHALL PARTICIPATE AT JOB COORDINATION MEETINGS WITH THE HENRY SCHEIN

REPRESENTATIVE AND ENSURE ATTENDANCE OF THE APPROPRIATE TRADES.

ALL TRADES SHALL DO THEIR OWN CUTTING. THE GENERAL CONTRACTOR SHALL DO ALL

PATCHING TO CONFORM TO MATERIAL, TEXTURE, AND SURFACE ALIGNMENT WITH THE

ADJOINING SURFACE AND FINAL TOUCH UP OF ALL FINISHED SURFACES.

THE GENERAL CONTRACTOR SHALL ENSURE THE PROTECTION OF ALL EQUIPMENT

FURNISHED UNDER HIS/HER CONTRACT AND BY OTHERS.

THE G.C. SHALL REVIEW ALL CUSTOM CABINETRY, SUCH AT THE RECEPTION DESK,

LABORATORY, AND STERILIZATION, WITH THE E.S. FOR ANY DENTAL EQUIPMENT

INCOPRORATION.

THE G.C. SHALL REMOVE ANY RUBBISH FROM THE CONSTRUCTION SITE AND ENSURE THAT ALL

PUBLIC SPACES ARE FREE OF CONSTRUCTION MATERIALS AND DEBRIS THROUGHOUT THE

DURATION OF THE CONTRACT. THE G.C. IS RESPONSIBLE FOR THE TOTAL CLEAN UP OF THE

JOB SITE UPON COMPLETION OF THEIR WORK.

THE GENERAL CONTRACTOR SHALL ISSUE A WRITTEN ONE-YEAR WARRANTY CERTIFICATE ON

ALL WORKMANSHIP AND MATERIALS FROM THE DATE OF OCCUPANCY, UNLESS NOTED

OTHERWISE IN THE CONSTRUCTION AGREEMENT BETWEEN THE OWNER AND THE G.C.. THIS

CERTIFICATE SHALL BIND THE GENERAL CONTRACTOR TO PROMPTLY CORRECT, REPAIR, OR

REPLACE, ANY DEFECTIVE EQUIPMENT OR WORKMANSHIP THAT WAS THE RESPONSIBILITY OF

THE G.C., WITHOUT COST TO THE OWNER.

5. SEPARATE CONTRACTS BY OWNER

THE OWNER RESERVES THE RIGHT TO PERFORM WORK RELATED TO THE PROJECT WITH

HIS/HER OWN FORCES, AND TO AWARD SEPARATE CONTRACTS IN CONNECTION WITH

OTHER PORTIONS OF THE PROJECT OR ON OTHER WORK ON THE SITE UNDER THESE OR

SIMILAR CONDITIONS OF CONTRACT. IF THE GENERAL CONTRACTOR CLAIMS THAT DELAY

OR ADDITIONAL COST IS INVOLVED BECAUSE OF SUCH ACTION BY THE OWNER, THE G.C.

MUST ENSURE THAT THEIR CLAIM WAS ORIGINALLY PART OF THEIR CONTRACT AGREEMENT.

THE G.C. SHALL AFFORD THE OWNER AND SEPARATE CONTRACTORS REASONABLE

OPPORTUNITY FOR THE INTRODUCTION AND STORAGE OF THEIR MATERIALS AND EQUIPMENT

AND THE EXECUTION OF THEIR WORK. THE G.C. SHALL CONNECT AND COORDINATE THEIR

WORK WITH OTHERS AS REQUIRED BY THE CONTRACT DOCUMENTS. ANY COSTS CAUSED BY

DEFECTIVE AND/OR ILL-TIME WORK SHALL BE BORNE BY THE PARTY RESPONSIBLE.

SEE OWNER OR OWNER'S AGENT FOR NON-DENTAL ITEMS AND AREAS NOT DETAILED IN

THESE DRAWINGS (SUCH AS RECEPTION, BUSINESS AREA, OFFICES, STAFF LOUNGE, STORAGE

ROOMS, OFFICE-WIDE SOUND SYSTEMS, CONTROLS, ETC.).

GENERAL NOTES

1. THESE DRAWINGS AND SPECIFICATIONS HAVE BEEN PRODUCED FOR THIS SPECIFIC PROJECT

ONLY, AND SHALL REMAIN THE EXCLUSIVE PROPERTY OF HENRY SCHEIN INC. THESE

DRAWINGS AND SPECIFICATIONS MAY NOT BE REPRODUCED OR USED FOR ANY OTHER

PURPOSE WITHOUT EXPRESSED WRITTEN CONSENT AND FULL PAYMENT OF ANY ASSOCIATED

FEES TO HENRY SCHEIN, INC.

2. ALL COMMUNICATIONS AND COORDINATION WITH TRADES SHALL BE THE RESPONSIBILITY OF

THE G.C. UNLESS STATED OTHERWISE IN THE CONTRACT AGREEMENT.

3. THE G.C. MUST SIGN THIS SHEET STIPULATING THAT HE/SHE UNDERSTANDS AND WILL COMPLY

WITH ALL SPECIFICATIONS BEFORE THE WORK WILL START. A SIGNED COPY OF THE PLANS

ARE TO BE RETURNED TO THE OWNER AND HENRY SCHEIN DENTAL.

4. IT IS THE RESPONSIBILITY OF A SUBCONTRACTOR TO READ AND UNDERSTAND ALL NOTES AND

ILLUSTRATIONS PERTAINING TO THEIR TRADE AND HOW THEIR WORK AFFECTS OTHER TRADES.

5. THE SUPPLY AND INSTALL OF THE CABINETS AND COUNTERTOPS, OTHER THAN THOSE

SPECIFIED AND/OR CONTRACTED BY HENRY SCHEIN, INC., IS THE RESPONSIBILITY OF THE

G.C..

6. THE OWNER SHALL MAKE ARRANGEMENTS FOR INSTALLATION OF NON-DENTAL SYSTEMS

UNDER A SEPARATE CONTRACT BEFORE WALLS ARE ENCLOSED.

7. ROUGH-IN AND FINISH WORK FOR DENTAL EQUIPMENT IS TO BE ACCORDING TO TEMPLATES

FURNISHED BY THE MANUFACTURERS OF EQUIPMENT BEING INSTALLED. THE E.S. WILL

POSITION THE TEMPLATES IN THEIR PROPER LOCATIONS, AT WHICH TIME ALL SPECIFICATIONS

ON THE PLANS WILL BE EXPLAINED TO THE GENERAL CONTRACTOR OR SUBCONTRACTOR(S).

ALL SPECIFIED SIZES OF PIPES, TUBING, FITTINGS, ETC., AS WELL AS PROPER HEIGHTS MARKED, MUST BE STRICTLY FOLLOWED. ANY DEVIATIONS ON SIZES OR HEIGHTS OF PIPES, TUBING, AND/OR FITTINGS MUST BE CORRECTED BEFORE THE EQUIPMENT CAN BE INSTALLED, AND

ANY SUCH EXTRA EXPENSE WILL BE THE RESPONSIBILITY OF G.C. AND/OR THE SUBTRADE.

8. THE G.C. SHALL SEAL ANY/ALL FLOOR AND FIRE PENETRATIONS MADE BY HENRY SCHEIN

INSTALLERS AT THE FINISHING STAGES WITH THE APPROPRIATE MATERIAL.

9. THE G.C. SHALL PROVIDE DOOR THRESHOLDS & DOOR SEALS NECESSARY FOR DENTAL

EQUIPMENT SOUND ATTENUATION.

10. THE GENERAL CONTRACTOR SHALL SUPPLY FASTENERS, ANCHORS, ACCESSORIES AND

ADHESIVES REQUIRED FOR FABRICATION AND ERECTION OF THE WORK. KEEP EXPOSED

FASTENERS TO A MINIMUM, NEATLY LAID OUT AND EVENLY SPACED. FLOOR FINISHES ARE TO

BE CONTINUOUS UNDERNEATH MILLWORK AND EQUIPMENT. TRANSITIONS AND VARIATIONS

BETWEEN FLOOR FINISHES TO BE SMOOTH AND LEVEL TO REDUCE INJURY WITH USE. PROVIDE

3/4'' (19MM) PLYWOOD SUPPORT BETWEEN STUDS FOR ALL WALLS TO SUPPORT UPPER

CABINETRY AND SHELVING, INCLUDING RECEPTION AND ALL TREATMENT ROOMS. WOOD

SUPPORTS ABOVE THE CEILING MAY NEED TO BE FIRE RATED, FOLLOW LOCAL CODES.

11. PRIOR TO POURING THE CONCRETE FLOOR AND ENCLOSING ALL WALLS, THE GENERAL

CONTRACTOR SHALL CONTACT THE E.S. AND INSTALLATION TECHNICIAN FOR FINAL

INSPECTION OF PLUMBING, ELECTRICAL AND WOOD SUPPORTS.

12. ALL LABOR AND MATERIAL NECESSARY FOR CHANGES IN EXISTING PLUMBING, CARPENTRY, AND ELECTRICAL WORK MUST BE DONE AND SUPPLIED BY THE GENERAL CONTRACTOR AND

IS NOT INCLUDED IN THE COST OF EQUIPMENT.

13. ALL PLUMBING AND ELECTRICAL LINES ARE TO BE CONCEALED UNLESS OTHERWISE

SPECIFIED.

14. THE ELECTRICAL PANEL SHALL BE CONVENIENT AND ACCESSIBLE, MEET ELECTRICAL CODE

REQUIREMENTS, AND BE LOCATED IN THE SUITE. LOCATION TO BE APPROVED BY THE OWNER

AND LANDLORD. THE G.C. SHALL REVIEW THE LOCATION WITH THE E.S., AS WELL AS THE

LOCATIONS OF THE TELEPHONE SYSTEM AND SERVER.

15. HENRY SCHEIN, INC. SHALL NOT BE HELD RESPONSIBLE FOR SUPPLYING UL/ULC OR CSA

APPROVAL CERTIFICATES. THE G.C. MAY CONTACT THE MANUFACTURER IF REQUIRED.

16. THE ELECTRICAL SUBCONTRACTOR SHALL PROVIDE SPECIFIED TERMINATION BOXES,

RECEPTACLES AND ANY HARDWIRE CIRCUITS LOCATED IN CUSTOM DENTAL CABINETRY.

THEY ARE ALSO RESPONSIBLE FOR SUPPLYING GFCI RECEPTACLES WHERE REQUIRED BY

CODE.

17. THE G.C. IS TO MAKE ARRANGEMENTS FOR TEMPORARY POWER AND/OR DISCONNECTION

OF ELECTRICAL AND MECHANICAL SYSTEMS IF AND WHEN REQUIRED.

18. IF MULTIMEDIA SYSTEMS, SUCH AS ENTERTAINMENT TVS, MONITORS, OR NETWORK COMPUTER SYSTEMS, OR SECURITY SYSTEMS ARE SUPPLIED AND INSTALLED BY HENRY SCHEIN, INC., THEN THESE SYSTEMS WILL BE THEIR RESPONSIBILITY. WHEN THESE SYSTEMS, OR OTHER SYSTEMS, ARE

NOT PROVIDED BY HENRY SCHEIN, INC., HENRY SCHEIN, INC. SHALL NOT BE HELD

RESPONSIBLE FOR THEIR INSTALLATION OR COMMISSIONING.

19. HENRY SCHEIN, INC. WILL ASSEMBLE EQUIPMENT AND, WHERE SPECIFIED WITHIN THESE

DRAWINGS, CONNECT TO UTILITIES PROVIDED, SUCH CONNECTIONS BY OTHER TRADES ARE

SUPPLIED CORRECTLY AND COMPLETELY (WITH PROPER SHUT-OFF VALVES/FITTINGS/

OUTLETS/TERMINATIONS). VERIFY ALL CONTRACTOR RESPONSIBILITIES FOR FINAL

CONNECTIONS WITH THESE DRAWINGS AND HENRY SCHEIN DENTAL E.S.. DIRECT ANY

QUESTIONS REGARDING CONTRACTOR RESPONSIBILITIES TO HENRY SCHEIN DENTAL E.S.

PRIOR TO CONSTRUCTION.

20. WHEN APPLICABLE, THE G.C. SHALL BE RESPONSIBLE FOR PROCURING A PLUMBING

SUB-CONTRACTOR THAT IS CERTIFIED TO INSTALL NITROUS OXIDE~OXYGEN CONSCIOUS

SEDATION SYSTEMS AS DETAILED IN THESE PLANS. HENRY SCHEIN DENTAL IS A NITROUS OXIDE

SYSTEM END USER COMPONENT SUPPLIER AND DOES NOT MANUFACTURE OR DESIGN ANY

OF THESE SYSTEMS. ANY SYSTEM DESIGN SHOWN ON THESE PLANS BY HENRY SCHEIN DENTAL

IS TO BE USED AS AN ILLUSTRATION ONLY FOR THE PURPOSE OF LOCATING END USER OUTLET

STATIONS, CYLINDER ROOM MANIFOLD, AND ALARM PANEL. THE FINAL TRUNK SYSTEM

INSTALLATION SHALL ADHERE TO THE MECHANICAL ENGINEERING DRAWINGS PREPARED BY

A THIRD PARTY.

21. PLUMBING SUBCONTRACTOR SHALL PROVIDE GAS CERTIFICATION CREDENTIALS IN

ACCORDANCE WITH ANY REQUESTS BY THE OWNER, GENERAL CONTRACTOR, BUILDING

DEPARTMENT, OR HENRY SCHEIN DENTAL PRIOR TO COMMENCING WORK IF ANY TYPE OF

NITROUS~OXIDE SYSTEM IS BEING INCORPORATED INTO THE PROJECT.

PRIOR TO POURING THE CONCRETE FLOOR AND

ENCLOSING ALL WALLS AND CEILINGS, THE

GENERAL CONTRACTOR SHALL CONTACT THE E.S.

AND INSTALLATION TECHNICIAN FOR FINAL

INSPECTION OF PLUMBING, ELECTRICAL AND

WOOD SUPPORTS.

-I M

PO

RT

A N

T N O

TE

TH

IS

D O

C

UM

EN

T

HA

S

BE

EN

P

RE

PA

RE

D A

S A

N

IN

ST

RU

M

EN

T O

F

PR

O

FE

SS

IO

N A

L

SE

RV

IC

E A

N D

IS

N

O T

A N

A

RC

HI

TE

C

TU

RA

L

PL

A

N

TH

E

ID

EA

S/ D

ES

IG

N

IN

C

LU

D

ED

H

ER

EI

N

A

RE

T

HE

S O

LE

P

RO

PE

RT

Y

O F

HE

N

RY

S

C

HE

IN

, I

N C

. A N

D A

RE

P

RO

TE

C

TE

D U

N D

ER

C

O

PY

RI

G

HT

TH

ES

E

PL

A N

S M

A Y

N O

T

BE

U

SE

D O

R

RE

PR

O

D

UC

ED

W

ITH

O

UT

E

XP

RE

SS

ED

W

RI

TT

EN

C O

N

SE

N T

O F

HE

N

RY

S

C

HE

IN

, I

N C

A

N D

F

UL

L

PA

YM

EN

T O

F A

N Y

A

SS

O C

IA

TE

D D

ES

IG

N F

EE

S.

A

LL

D

IM

EN

SI

O N

S A

RE

S

UB

JE

C T

TO

J

O B-

SI

TE

V

ER

IF

IC

A

TIO

N

REVISIONS:

HENRY SCHEIN REP:

PR

O

JE

C

T:

LO

C

A

TIO

N

SCALE: SHT. SIZE:

INT.SQ.FT.=

2023 by HENRY SCHEIN, INC.c

REGION:

PHONE #:

PROJECT START DATE:

FINALS START DATE:

DRAWN BY:

FINALS BY:

CHECKED BY:

PROJECT NUMBER:

P:

\_A

LL

R

EG

IO

NS

\O

R Or eg on

-A las ka \A nc ho ra ge

C or re cti on al\

An ch or ag e C or re cit on al-

1I- D

W

L

IN

C O

LN

A

V E, W

ES

T A

LL

IS

, W I he nr ys ch ei ni nt eg ra te d d es ig n.

co m

H

EN

RY

SC

H

EI

N

R

IN

TE

G

RA

TE

D

D

ES

IG

N

S

TU

D

IO

A N

C H

O R

A G

E C

O R

R E

C T

IO

N

A L

N

C

HO

RA

G

E, A

K

DAVID SHEETS

OR/AK - OREGON

458.221.0009

03/01/2022

04/03/2023

ARCH

KH

AKL

PER ARCH

22-0516

BELOW -

COUNTER

STERILIZER

TRE.

ROOM

TRE.

ROOM

TRE.

ROOM

TRE.

ROOM

2A

3A

9 9A

9B

2A

3A

4A 4A

99A

9B

14A15 15B

PLEASE NOTE: A LICENSED CONTRACTOR IS RESPONSIBLE FOR PROVIDING

EQUIPMENT BLOCKING AND ALL REQUIRED UTILITIES. ALL REQUIREMENTS TO BE

VERIFIED BY MANUFACTURER'S SPEC SHEETS PROVIDED BY HENRY SCHEIN DENTAL

EQUIPMENT SPECIALIST. MANUFACTURER'S SPECS SUPERSEDE ANY AND ALL

INFORMATION CONTAINED HEREIN.

GENERAL SPECIFICATIONS

Q

UA

N

TIT

Y

SP

EC

. N

UM

BE

R

DESCRIPTION C

O

LD

W

A

TE

R

HO

T W

A

TE

R D

RA

IN

C O

M

PR

ES

SE

D A

IR

N

A

TU

RA

L

G A

S V

A C

UU

M

N 2O

O

XY

G

EN

N

ITR

O G

EN

V

EN

T

PO

W

ER

D

ED

IC

A

TE

D

C

IR

C

UI

T

LO

W

V O

LT

A

G E

C O

N

TR

O L

D A

TA

D

RO

P

UTILITIES

D

ET

A

IL

2A

3A

4A

9A

9B

14A

15B

UTILITY CENTER – SELF-CONTAINED WATER. SEE DETAIL(S). SELF-CONTAINED WATER. ALL

UTILITIES MUST CONFORM TO PREVAILING LOCAL CODES.

UTILITY CENTER - SELF-CONTAINED WATER. SEE DETAIL(S). ALL UTILITIES MUST CONFORM TO

PREVAILING LOCAL CODES.

2" SUB-FLOOR CONDUIT - SUB-FLOOR PIPE CHASE WITH PULL-STRING SUPPLIED & INSTALLED BY

ELECTRICIAN. SWEEPING 90 DEGREE BENDS ONLY. STUB-UP FLUSH WITH SUB-FLOOR AT EACH

END, MARK LOCATION AT FINISH.

DENTAL TRACK LIGHT - SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. BLOCKING AND

ELECTRICAL BY CONTRACTOR(S).

WALL MOUNTED INTRAORAL X-RAY HEAD, ARM, AND WALL BRACKET - SUPPLIED AND

INSTALLED BY HENRY SCHEIN DENTAL. BLOCKING & ELECTRICAL BY CONTRACTOR(S).

X-RAY MASTER CONTROL – SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. ELECTRICIAN TO SUPPLY AND INSTALL PIPE CHASE WITH PULL-STRING TO (9) LOCATION WHEN (9A) IS REMOTE.

VERIFY SUPPLIER OF WIRING WITH HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST.

X-RAY REMOTE EXPOSURE BUTTON – SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL.

ELECTRICIAN TO SUPPLY AND INSTALL PIPE CHASE WITH PULL-STRING TO (9A) OR (9C)

LOCATION. VERIFY SUPPLIER OF EXPOSURE BUTTON AND WIRING WITH HENRY SCHEIN DENTAL

EQUIPMENT SPECIALIST.

STERILIZER (AUTOCLAVE) - SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. POWER BY

ELECTRICIAN.

ULTRASONIC CLEANER - SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. UTILITIES BY

CONTRACTOR(S).

HANDPIECE MAINTENANCE SYSTEM - CONTRACTOR(S) TO PROVIDE REQ'D UTILITIES. 1/2" AIR

LINE WITH 1/4” ANGLE VALVE (ABOVE COUNTERTOP). SYSTEM SUPPLIED AND INSTALLED BY

HENRY SCHEIN DENTAL.

115V

115V

115V

115V

115V

115V

115V

20A

20A

2A

3A

4A

9B

14A

15B

SA.0

24 x 361/4"=1'-0"

DENTAL

DRAWINGS

NEW REINFORCEMENT PLACED FOR

CEILING-MOUNTED EQUIPMENT. SEE

"REINFORCEMENT SPECIFICATION SCHEDULE"

FOR MORE INFORMATION.

NEW REINFORCEMENT PLACED FOR WALL-

MOUNTED EQUIPMENT. SEE

"REINFORCEMENT SPECIFICATION

SCHEDULE" FOR MORE INFORMATION.

NEW WALLS TO BE CONSTRUCTED

WALL LEGEND

2. VERIFY ALL DIMENSIONS WITH HENRY SCHEIN DENTAL REP. ON

JOBSITE. ON SITE MODIFICATIONS MAY NEED TO BE DONE BY

CONTRACTOR, BUT SHOULD BE VERIFIED BY ALL PARTIES INVOLVED.

3. USE 5/8" GYPSUM WALLBOARD THROUGHOUT THE OFFICE TO

PROVIDE EXTRA PROTECTION AGAINST X-RAY SCATTER RADIATION.

1. THIS SPECIFICATION SHEET IS INTENDED AS A GUIDE FOR TRADESMEN.

THE FLOOR PLANS ENCLOSED HEREIN ARE SUGGESTIONS FOR THE

PLACEMENT OF DENTAL EQUIPMENT. THEY ARE NOT INTENDED FOR

CONSTRUCTION.

CONSTRUCTION NOTES

DIMENSIONS AND REINFORCEMENT SPECIFICATIONS

PROPOSED FLOOR PLAN

DENTAL SPECIFICATIONS

SCALE: 1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

*SPECIFICATIONS MAY INCLUDE DATA, SEE ELECTRICAL

SCHEDULE THIS SHEET

SEE SHEET SED.1 FOR DENTAL EQUIPMENT DETAILS

VACUUM NOTES

THE VACUUM PIPING LAYOUT HAS A LARGE EFFECT ON THE EFFICIENCY

AND RELIABILITY OF THE DENTAL VACUUM SYSTEM. REFER TO

MANUFACTURER'S PRE-INSTALLATION GUIDE PROVIDED BY HENRY

SCHEIN EQUIPMENT SPECIALIST FOR SPECIFIC SIZING OF STUB-UP,

TRUNK, AND BRANCH LINES.

IT IS HIGHLY RECOMMENDED THAT VACUUM LINES RUN UNDERNEATH

DENTAL EQUIPMENT BY MEANS OF TRENCHING/ CORING (CONCRETE

SLAB) OR IN SUB FLOOR (BASEMENT/ CRAWL SPACE). ALL LINES ARE TO

BE DESIGNED WITH PVC PIPING UNLESS DICTATED BY LOCAL CODES TO

USE COPPER OR CAST IRON.

TO ENSURE OPTIMUM VACUUM PERFORMANCE, INSTALL MAIN LINE

DIRECTLY BELOW THE DENTAL CHAIR, CABINET OR WALL JUNCTION

BOX TO REDUCE OR ELIMINATE BRANCH LINE RUNS WHEREVER

POSSIBLE.

I. TERMINATION

TERMINATE VACUUM TRUNK LINE IN MECHANICAL ROOM. PLUMBING

CONTRACTOR TO PROVIDE FPT ADAPTOR ON END OF STUB-UP FROM

FLOOR OR WALL. SIZE OF ADAPTOR TO BE DETERMINED BY TRUNK AND

PUMP INTAKE PIPE SIZES. SEE DETAILS THIS SET & MANUFACTURER

TEMPLATES PROVIDED BY HENRY SCHEIN EQUIPMENT REP. IN THE CASE

OF DUAL TRUNK LINE SYSTEM, PROVIDE ENOUGH SPACE BETWEEN

STUB-UPS TO INSTALL TEES ON BOTH LINES.

2. TRUNK LINE(S)

VACUUM TRUNK LINES(S) TO BE SUPPORTED EVERY 6'-0" TO PREVENT

SAG AND SLOPED A MINIMUM OF 1/4" PER 10'-0" TOWARD THE

VACUUM PUMP.

3. BRANCH LINE(S)

BRANCH LINES ARE TO HAVE "SWEEPING" 90 DEGREE TURNS TO AVOID

VACUUM LOSS. A "WYE" FITTING SHOULD BE USED TO JOIN BRANCH

LINES TO THE TRUNK LINE.

SPECIAL NOTE:

IF VACUUM LINES ENCROACH ON EITHER A WALL OR COLUMN

FOOTING, USE 45 DEGREE ELBOWS TO PIPE AROUND FOOTING SO PIPE

REACHES PROPER LOCATION.

WYE FITTING

MAIN LINE

45 ELBOWS

BRANCH LINE CONFIGURATION

SUB FLOOR

FLOW

PUMP

TO

FLOW

DO NOT PIPE TRUNK LINE IN A SERIES

MANNER LOOPING FROM J-BOX TO

J-BOX. A CONTINUOUS TRUNK LINE MUST

BE MAINTAINED FROM THE PUMP TO THE

FURTHEST J-BOX USING BRANCH LINES

OFF OF THE TRUNK LINE TO PICK UP EACH

VACUUM OUTLET. TRUNK LINE MAY

FOLLOW DRAIN LINE TRENCHES WITHIN

REASON. USE ONLY 45 DEGREE EL'S. DO

NOT USE ANY 90 DEGREE EL'S. ALL SUB

FLOOR SCH 40 PVC CONNECTIONS ARE

TO BE PLUMBED WITH 45 DEGREE EL'S

USING DETAIL A FOR TEEING BRANCH

LINE CONNECTIONS INTO TRUNK LINE.

DETAIL A

WYE FITTING (USE FOR ALL SUB

FLOOR INTERSECTIONS)

ELECTRICAL NOTES

5. ADDITIONAL CONVENIENCE OUTLETS REQUIRED ON JOBSITE ARE THE

RESPONSIBILITY OF ELECTRICAL CONTRACTORS. FOLLOW LOCAL CODE

RESTRICTIONS.

4. GFCI PROTECTION OR REDUNDANT GROUND IN DENTAL CHAIR

RECEPTACLES, DENTAL UTILITY CABINETS AND ANY OTHER AREAS

REQUIRED BY LOCAL CODE IS THE RESPONSIBILITY OF THE ELECTRICAL

CONTRACTOR.

2. EXACT EQUIPMENT LOCATIONS MUST BE JOB SITE VERIFIED BY THE

HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST.

3. FOLLOW MANUFACTURER'S TEMPLATES FOR EXACT REQUIREMENTS

FOR ANY EQUIPMENT SUPPLIED BY HENRY SCHEIN DENTAL. CONSULT

WITH HENRY SCHEIN DENTAL REP FOR ADDITIONAL INFORMATION.

1. THIS SPECIFICATION SHEET IS INTENDED AS A GUIDE FOR TRADESMEN.

THE FLOOR PLANS ENCLOSED HEREIN ARE SUGGESTIONS FOR THE

PLACEMENT OF DENTAL EQUIPMENT. THEY ARE NOT INTENDED FOR

CONSTRUCTION.

7. ALL COMPUTER NETWORKING AND WORKSTATIONS MUST BE

SPECIFIED BY CUSTOMER'S COMPUTER SUPPLIER. IF HENRY SCHEIN WILL

BE SUPPLYING THE COMPUTERS & NETWORKING COMPONENTS, SEE

SHEET SE.2 FOR THE OFFICE TECHNOLOGY PLAN.

8. CONTRACTOR TO PROVIDE AND INSTALL ALL EXIT SIGNS, EMERGENCY

LIGHTING AND FIRE SUPPRESSION & DETECTION SYSTEMS AS PER

ARCHITECT'S DRAWINGS AND LOCAL CODE.

9. REFER TO ARCHITECT'S DRAWINGS FOR ELECTRICAL REQUIREMENTS IN

ALL AREAS NOT INDICATED ON THIS PLAN.

ALL DIMENSIONS NOTED ON PLAN ARE TO THE CENTERLINE

OF RECEPTACLE OR UTILITY CENTER

(UNLESS SHOWN OTHERWISE)

6. ALL CONDUIT LOCATIONS SHOULD BE VERIFIED WITH OWNER AND

HENRY SCHEIN REP PRIOR TO ROUGH-IN.

PO

RT

A N

T N O

TE

TH

IS

D O

C

UM

EN

T

HA

S

BE

EN

P

RE

PA

RE

D A

S A

N

IN

ST

RU

M

EN

T O

F

PR

O

FE

SS

IO

N A

L

SE

RV

IC

E A

N D

IS

N

O T

A N

A

RC

HI

TE

C

TU

RA

L

PL

A

N

TH

E

ID

EA

S/ D

ES

IG

N

IN

C

LU

D

ED

H

ER

EI

N

A

RE

T

HE

S O

LE

P

RO

PE

RT

Y

O F

HE

N

RY

S

C

HE

IN

, I

N C

. A N

D A

RE

P

RO

TE

C

TE

D U

N D

ER

C

O

PY

RI

G

HT

TH

ES

E

PL

A N

S M

A Y

N O

T

BE

U

SE

D O

R

RE

PR

O

D

UC

ED

W

ITH

O

UT

E

XP

RE

SS

ED

W

RI

TT

EN

C O

N

SE

N T

O F

HE

N

RY

S

C

HE

IN

, I

N C

A

N D

F

UL

L

PA

YM

EN

T O

F A

N Y

A

SS

O C

IA

TE

D D

ES

IG

N F

EE

S.

A

LL

D

IM

EN

SI

O N

S A

RE

S

UB

JE

C T

TO

J

O B-

SI

TE

V

ER

IF

IC

A

TIO

N

REVISIONS:

HENRY SCHEIN REP:

PR

O

JE

C

T:

LO

C

A

TIO

N

SCALE: SHT. SIZE:

INT.SQ.FT.=

2023 by HENRY SCHEIN, INC.c

REGION:

PHONE #:

PROJECT START DATE:

FINALS START DATE:

DRAWN BY:

FINALS BY:

CHECKED BY:

PROJECT NUMBER:

P:

\_A

LL

R

EG

IO

NS

\O

R Or eg on

-A las ka \A nc ho ra ge

C or re cti on al\

An ch or ag e C or re cit on al-

1I- F

W

L

IN

C O

LN

A

V E, W

ES

T A

LL

IS

, W I he nr ys ch ei ni nt eg ra te d d es ig n.

co m

H

EN

RY

SC

H

EI

N

R

IN

TE

G

RA

TE

D

D

ES

IG

N

S

TU

D

IO

A N

C H

O R

A G

E C

O R

R E

C T

IO

N

C

HO

RA

G

E, A

K

DAVID SHEETS

OR/AK - OREGON

458.221.0009

03/01/2022

04/03/2023

ARCH

KH

AKL

PER ARCH

22-0516

PLUMBING NOTES

5. WATER PRESSURE MUST NOT EXCEED 50 PS1 AT ALL DENTAL UNITS.

6. ALL PLUMBING MUST CONFORM TO LOCAL PREVAILING CODES.

3. FOLLOW MANUFACTURER'S TEMPLATES FOR EXACT REQUIREMENTS

FOR ANY EQUIPMENT SUPPLIED BY HENRY SCHEIN DENTAL. CONSULT

WITH HENRY SCHEIN DENTAL REP FOR ADDITIONAL INFORMATION.

1. THIS SPECIFICATION SHEET IS INTENDED AS A GUIDE FOR TRADESMEN.

THE FLOOR PLANS ENCLOSED HEREIN ARE SUGGESTIONS FOR THE

PLACEMENT OF DENTAL EQUIPMENT. THEY ARE NOT INTENDED FOR

CONSTRUCTION.

2. EXACT EQUIPMENT LOCATIONS MUST BE JOB SITE VERIFIED BY THE

HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST.

7. REFER TO ARCHITECT'S DRAWINGS FOR PLUMBING REQUIREMENTS IN

ALL AREAS NOT INDICATED ON THIS PLAN.

ALL DIMENSIONS NOTED ON PLAN ARE TO THE CENTERLINE

OF PLUMBING OR UTILITY CENTER

(UNLESS SHOWN OTHERWISE)

4. DENTAL AIR IS SUPPLIED THROUGH USE OF A DENTAL AIR

COMPRESSOR/SUPPLY SYSTEM AND IS PERMITTED TO BE USED AS A

SUPPORT GAS FOR DRIVING DENTAL TOOLS AND SUPPLYING AIR-DRIVEN

EQUIPMENT AS DESCRIBED WITHIN NFPA 99. DENTAL AIR IS NOT A

MEDICAL GAS.

THIS PLAN IS FOR THE SOLE PURPOSE OF SPECIFICATION AND

INSTALLATION OF THE DENTAL EQUIPMENT SUPPLIED BY HENRY

SCHEIN DENTAL. THE SPACE PLANNING AND CONCEPTUAL

DESIGN HAS BEEN PROVIDED BY OTHERS AND THE IDEAS

HEREIN ARE NOT NECESSARILY RECOMMENDED BY THE HENRY

SCHEIN INTEGRATED DESIGN STUDIO .TM

DENTAL CHAIR AND CABINET UTILITIES TO BE LOCATED ON

JOB-SITE PER MANUFACTURER'S TEMPLATES. LOCATIONS TO

BE APPROVED BY DOCTOR AND HENRY SCHEIN EQUIPMENT

SPECIALIST PRIOR TO ROUGH-IN.

ALL NEW TREATMENT ROOM UTILITIES TO BE TIED INTO EXISTING

DENTAL MECHANICAL SYSTEMS. SEE HENRY SCHEIN REP.

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text 2'-3"

AutoCAD SHX Text 2'-3"

AutoCAD SHX Text 10"

AutoCAD SHX Text 10"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

NOTES:

1. DETAIL PROVIDED FOR UTILITY REQUIREMENTS.

REFER TO MANUFACTURER'S INSTALLATION GUIDE

FOR ADDITIONAL INFORMATION. HENRY SCHEIN

DENTAL EQUIPMENT SPECIALIST WILL PROVIDE

INSTALLATION TEMPLATE UPON REQUEST.

2. INSTALLATION MUST CONFORM TO ALL LOCAL

ELECTRICAL AND PLUMBING CODES.

3. ALL UTILITIES HEREIN TO BE SUPPLIED & INSTALLED BY

LICENSED CONTRACTORS. FINAL CONNECTIONS

TO EQUIPMENT BY HENRY SCHEIN DENTAL.

4. ALL UTILITIES MUST BE NO HIGHER THAN 4 14" A.F.F.

AT FINISH.

5. ALL PLUMBED SYSTEMS MUST BE FLUSHED CLEAN OF

ANY DEBRIS PRIOR TO EQUIPMENT INSTALLATION.

2A A-DEC 411 CHAIR UTILITIES

NOT TO SCALE

TOP VIEW

CL

COMPRESSED AIR: 1/2" SUPPLY LINE FROM COMPRESSOR BY PLUMBER. STUB-UP FROM FLOOR 1”-2”.

TERMINATE WITH 3/8” ANGLE VALVE. PRESSURE 100 PSI MAX.

ELECTRICAL: TWO GANG BOX & 115V DUPLEX OUTLET BY ELECTRICIAN. CHAIR MAX DRAW: 10A

CHASE: GRAY ELECTRICAL PVC PIPE CHASE WITH PULL-STRING BY ELECTRICIAN (SEE SHEET SE.1 FOR SIZE & LOCATIONS). 6" MIN. RADIUS FOR ALL BENDS. STUB-UP FLUSH WITH SUB-FLOOR, MARK LOCATION AT FINISH.

TOE OF CHAIR

C L

HEAD OF CHAIR

UTILITY CENTER FRAME

E

A

C

A

E

C

C

A V

MANUFACTURER PROVIDED

JUNCTION BOX & QUAD

OUTLET (APPROX.

LOCATION AND

ORIENTATION)

NOTES:

1. DETAIL PROVIDED FOR UTILITY REQUIREMENTS.

REFER TO MANUFACTURER'S INSTALLATION GUIDE

FOR ADDITIONAL INFORMATION. HENRY SCHEIN

DENTAL REP WILL PROVIDE INSTALLATION TEMPLATE

UPON REQUEST.

2. INSTALLATION MUST CONFORM TO ALL LOCAL

ELECTRICAL AND PLUMBING CODES.

3. ALL UTILITIES HEREIN TO BE SUPPLIED & INSTALLED BY

LICENSED CONTRACTORS. FINAL CONNECTIONS

TO EQUIPMENT BY HENRY SCHEIN DENTAL.

4. ALL VALVES, BOXES AND PIPES FROM FLOOR MUST

BE NO HIGHER THAN 5" A.F.F.

5. ALL PLUMBED SYSTEMS MUST BE FLUSHED CLEAN OF

ANY DEBRIS PRIOR TO EQUIPMENT INSTALLATION.

3A ADEC 5580 CABINET UTILITIES

NOT TO SCALE

TOP VIEW (FLOOR OPTION)

COMPRESSED AIR: 1/2" SUPPLY LINE FROM COMPRESSOR BY PLUMBER. STUB-UP FROM FLOOR 1”-2”.

TERMINATE WITH 3/8” ANGLE VALVE. PRESSURE 100 PSI MAX.

ELECTRICAL: 16" ELECTRICAL WHIP TERMINATED PER CODE FOR CONNECTION TO MANUFACTURER

PROVIDED JUNCTION BOX.

CHASE: GRAY ELECTRICAL PVC PIPE CHASE WITH PULL-STRING BY ELECTRICIAN (SEE SHEET SE.1 FOR SIZE & LOCATIONS). 6" MIN. RADIUS FOR ALL BENDS. STUB-UP FLUSH WITH SUB-FLOOR, MARK LOCATION AT FINISH.

CENTRAL VACUUM: 1/2" COPPER BRANCH LINE RISER BY PLUMBER. TERMINATE 1-2" A.F.F.

A

E

C

V

ELEVATION VIEW (WALL OPTION)

UTILITIES TO BE RUN IN

FLOOR OR WALL BASED

ON SITE CONDITIONS

CL

A

V

UTILITIES TO STUB-OUT

FROM WALL 6" (MIN.)

FINISHED

FLOOR

16" ELECTRICAL

WHIP TO EXTEND

FROM STUB-OUT

FOR HOOK-UPS

CL

E

BACK OF CABINET

COUNTERTOP ABOVE

E

C

4A SUB-FLOOR CHASE

NOT TO SCALE

FOLLOW LOCAL CODES FOR ALL WORK.

TERMINATE CONDUIT IN BASE OF

REAR CABINET OR IN WALL. SEE

REAR CABINET DETAIL. COORDINATE

WITH HENRY SCHEIN REP.

2" CONDUIT - PIPE CHASE WITH

PULL-STRING SUPPLIED AND

INSTALLED BY CONTRACTOR. 6"

MIN. SWEEPING BENDS. STUB-UP

FLUSH WITH SUB-FLOOR, MARK

LOCATION OF PIPE AT FINISH.

SEE CHAIR/CABINET/CART UTILITY

CENTER DETAIL FOR CONDUIT

TERMINATION LOCATION.

COORDINATE WITH HENRY SCHEIN REP.

PRODUCT SPECIFICATIONS

1 - 5A 60-120

NOTES:

1. DETAIL PROVIDED FOR BLOCKING & UTILITY

REQUIREMENTS. REFER TO MANUFACTURER'S

INSTALLATION GUIDE FOR ADDITIONAL

INFORMATION.

2. INSTALLATION MUST CONFORM TO ALL LOCAL

FRAMING AND ELECTRICAL CODES.

3. PROVIDE ADEQUATE BLOCKING AND STRUCTURAL

BRACING TO SUPPORT A PULL OF 500 LBS.

BLOCKING MUST BE LEVEL.

4. MOUNTING MATERIALS SUPPLIED AND INSTALLED BY

CONTRACTOR.

5. FINAL CONNECTIONS TO BE MADE BY HENRY

SCHEIN DENTAL.

NOMINAL VAC RATING

VOLTAGE MIN/MAX

FULL LOAD AMPS

WEIGHT (LBS)

108/132

SUPPORT STRUCTURE AND BRACING SPECIFIED BY

ENGINEER, SUPPLIED AND INSTALLED BY CONTRACTOR.

FINISHED CEILING

6 TYPICAL TRACK MOUNTED DENTAL LIGHT

NOT TO SCALE

TRACK LIGHT PALETTE, SUPPLIED

AND INSTALLED BY HENRY SCHEIN

DENTAL AT FINISH.

FRONT VIEW

SIDE VIEW

BLOCKING - SINGLE 2x12, CUT TO SIZE OF PLYWOOD

PALETTE SHIPPED WITH TRACK LIGHT. SEE HENRY SCHEIN

REP. MOUNT FLUSH WITH FINISHED CEILING. REINFORCE

WITH 2x4 STUDS ON BOTH SIDES. FOR

NON-COMBUSTABLE CONSTRUCTION, FRT LUMBER MAY

BE USED OR BLOCKING MAY BE WRAPPED IN FIRECODE

CORE GYP. BRD. FOLLOW LOCAL CODES. BACKING

MUST BE LEVEL

ELECTRICIAN TO PROVIDE JUNCTION BOX

& 115V POWER FEED WITH 6' WHIP ABOVE

CEILING FOR TRACK LIGHT. SEE HENRY

SCHEIN REP FOR FINAL TERMINATION

POINT, DRILL HOLE & FEED WHIP THROUGH

BACKING INTO TRACK LIGHT FOR FINAL

CONNECTIONS.

9 PROGENY PREVA X-RAY

NOT TO SCALE

FOLLOW LOCAL CODES FOR ALL WORK.

DETAIL PROVIDED FOR BLOCKING & UTILITY

REQUIREMENTS. REFER TO MANUFACTURER'S

INSTALLATION GUIDE FOR ADDITIONAL

INFORMATION.

THE WALL FABRICATION AND ATTACHMENTS TO

THE BUILDING STRUCTURE MUST BE CAPABLE OF

WITHSTANDING A LOAD MOMENT OF 850 FT. LBS.,

100 LB. SHEAR LOAD AND A 500 LB. WITHDRAWAL

FORCE AT EACH OF THE MOUNTING BOLTS.

FRAMING SHOULD ALLOW ALL FOUR MOUNTING

BOLTS TO ENTER SOLID WOOD. MOUNTING

MATERIALS SUPPLIED AND INSTALLED BY

CONTRACTOR.

STACKED 2 x 4 OPTION (TOP VIEW)

1/2" OR 5/8" PLYWOOD

(BASED ON FRAMING TYPE)

5/8" GYP. BRD. AT FINISH

MOUNTING PLATE AND BOLT

FASTEN LAYERS TOGETHER TO AVOID SHIFTING.

BOLTS MUST FASTEN TO THE LONG SIDE OF 2 x 4

STUD (AS SHOWN).

2 X 4 S. YELLOW PINE NO. 2

2 X 4 S. YELLOW PINE NO. 2

PROPERLY SECURE FRAMING TO

STRUCTURE ABOVE FOLLOWING LOCAL

CODES

TWO GANG BOX WITH 115V POWER FEED

ON DEDICATED 20A CIRCUIT BY

ELECTRICIAN. PROVIDE 18" WHIP.

X-RAY MAX DRAW: 5A

SINGLE-GANG JUNCTION BOX AND

CONDUIT TO ABOVE CEILING (OR PER

CODE) WITH PULL-STRING BY

ELECTRICIAN TO 9A (IF REMOTE) OR 9B.

25' OF CABLE PROVIDED, SEE HENRY

SCHEIN REP.

4 X 4 DOUGLAS FIR-LARCH POSTS BY

CONTRACTOR. SEE STACKED 2 X 4

OPTION DETAIL BELOW IF STRAIGHT,

SOLID 4 X 4 POSTS ARE NOT AVAILABLE.

X-RAY MOUNTING PLATE SUPPLIED AND

INSTALLED BY HENRY SCHEIN DENTAL AT

FINISH. SECURE PLATE USING 3/8"X4"

FULLY-THREADED LAG SCREWS. FINAL

CONNECTIONS BY HENRY SCHEIN

DENTAL.

9B X-RAY EXPOSURE BUTTON

NOT TO SCALE

FOLLOW LOCAL CODES FOR ALL WORK.

DETAIL PROVIDED FOR UTILITY REQUIREMENTS.

REFER TO MANUFACTURER'S INSTALLATION

GUIDE FOR ADDITIONAL INFORMATION.

EXPOSURE BUTTON SUPPLIED AND

INSTALLED BY HENRY SCHEIN

DENTAL AT FINISH.

SINGLE-GANG JUNCTION BOX &

CONDUIT TO ABOVE CEILING (OR

PER CODE) WITH PULL-STRING BY

ELECTRICIAN TO 9A OR 9C

LOCATION. SEE SHEET SE.1.

14A AUTOCLAVE STERILIZER (UNDER COUNTER)

NOT TO SCALE

SINGLE GANG BOX & DUPLEX

OUTLET ON A 115V, 20A

DEDICATED CIRCUIT BY

ELECTRICIAN.

FOLLOW LOCAL CODES FOR ALL WORK.

DETAIL PROVIDED FOR UTILITY REQUIREMENTS.

REFER TO MANUFACTURER'S INSTALLATION

GUIDE FOR ADDITIONAL INFORMATION.

DENTAL STERILIZER SUPPLIED AND

INSTALLED BY HENRY SCHEIN

DENTAL.

VERIFY DIMENSIONS WITH CONTRACTOR AND

CABINET MAKER

15 ULTRASONIC CLEANER (COUNTERTOP)

NOT TO SCALE

SINGLE GANG BOX & 115V

DUPLEX OUTLET BY ELECTRICIAN.

FOLLOW LOCAL CODES FOR ALL WORK.

DETAIL PROVIDED FOR UTILITY REQUIREMENTS.

REFER TO MANUFACTURER'S INSTALLATION

GUIDE FOR ADDITIONAL INFORMATION.

ULTRASONIC CLEANER SUPPLIED

AND INSTALLED BY HENRY

SCHEIN DENTAL.

15B A-DEC ASSISTINA TWIN MAINTENANCE SYSTEM

NOT TO SCALE

FOLLOW LOCAL CODES FOR ALL WORK.

DETAIL PROVIDED FOR UTILITY REQUIREMENTS.

REFER TO MANUFACTURER'S INSTALLATION

GUIDE FOR ADDITIONAL INFORMATION.

ASSISTINA UNIT SUPPLIED AND

INSTALLED BY HENRY SCHEIN

DENTAL.

1/2" AIR SUPPLY LINE FROM

COMPRESSOR BY CONTRACTOR.

STUB-OUT FROM WALL 1”-2”.

TERMINATE WITH 1/4” ANGLE VALVE.

PRESSURE 100 PSI MAX.

SINGLE GANG BOX & 115V

DUPLEX OUTLET BY ELECTRICIAN.

SED.1

24 x 36SEE DETAIL

DENTAL EQUIP.

DETAILS

PO

RT

A N

T N O

TE

TH

IS

D O

C

UM

EN

T

HA

S

BE

EN

P

RE

PA

RE

D A

S A

N

IN

ST

RU

M

EN

T O

F

PR

O

FE

SS

IO

N A

L

SE

RV

IC

E A

N D

IS

N

O T

A N

A

RC

HI

TE

C

TU

RA

L

PL

A

N

TH

E

ID

EA

S/ D

ES

IG

N

IN

C

LU

D

ED

H

ER

EI

N

A

RE

T

HE

S O

LE

P

RO

PE

RT

Y

O F

HE

N

RY

S

C

HE

IN

, I

N C

. A N

D A

RE

P

RO

TE

C

TE

D U

N D

ER

C

O

PY

RI

G

HT

TH

ES

E

PL

A N

S M

A Y

N O

T

BE

U

SE

D O

R

RE

PR

O

D

UC

ED

W

ITH

O

UT

E

XP

RE

SS

ED

W

RI

TT

EN

C O

N

SE

N T

O F

HE

N

RY

S

C

HE

IN

, I

N C

A

N D

F

UL

L

PA

YM

EN

T O

F A

N Y

A

SS

O C

IA

TE

D D

ES

IG

N F

EE

S.

A

LL

D

IM

EN

SI

O N

S A

RE

S

UB

JE

C T

TO

J

O B-

SI

TE

V

ER

IF

IC

A

TIO

N

REVISIONS:

HENRY SCHEIN REP:

PR

O

JE

C

T:

LO

C

A

TIO

N

SCALE:…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .