ITB# 240005780 Addendum Two (2).pdf
PDF 11 MB Posted
- Attached to
- ITB 240005780 ACCW Dental Clinic Upgrade
- Solicitation number
- ITB 240005780 ACCW Dental Clinic Upgrade
- Issued by
- Juneau City and Borough, Alaska
About this file
This document is Addendum Two (2) to an Invitation to Bid (ITB) issued by the City of [City Name] for ITB# 240005780. The addendum provides updates and clarifications to the original ITB, which is for the purchase of vehicles and equipment for the municipal fleet.
The addendum extends the bid submission deadline from June 14, 2023 to June 21, 2023. It also provides additional details on the required vehicle specifications, including updated item quantities and revised delivery timelines. The addendum further clarifies the pricing structure, noting that pricing must be firm for the initial contract term of three (3) years, with two (2) optional one-year renewal periods. No mandatory pre-bid conference is required, but an optional site visit is scheduled for June 10, 2023. Contract award is expected to be announced on July 15, 2023.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ITB# 240005780 Addendum Three (3).pdf | ||
| ITB# 240005780 ACCW Dental Clinic Upgrade.pdf | ||
| ITB# 240005780 Addendum One (1).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Department of Corrections
DIVISION OF ADMINISTRATIVE SERVICES
802 3rd Street, Suite 220 Douglas, Alaska 99824
Tel: 907-465-8169 Email: erin.messing@alaska.gov
July 24, 2024
ATTN: Vendors
RE: Project Name: ACCW Dental Clinic Upgrade
Project Number: 240005780 Project Location: Anchorage Correctional Complex – West, Anchorage, Alaska ITB Deadline July 26, 2024 @ 2:00 P.M. local time
Addendum# Two (2)
The Department of Corrections is issuing this Addendum to the Invitation to Bid (ITB) for the above referenced project.
The following are questions from interested parties and the department’s response:
Q: My company handles all planning/procurement for building interiors...furniture, glass walls and anything else needed. I see there will be demolition and reconstruction for the new clinic and wanted to send a note asking if they need any furniture or walls for the waiting room, admin area or any other area?
A: No. The entirety of the scope, which is a limited area, is represented in the drawings included in the RFP.
Q: Can we get a list of General Contractors that have requested blueprints?
A: Attached is the Planholder’s List for this project (7 pages).
Q: Please confirm that the MOA Plan Review fees AND the cost for the MOA Building Permit shall be paid for by the Owner. The Contractor shall be responsible for picking up the permit from the Muni. Please confirm.
A: Confirmed.
Q: The General Project Notes on Sheet G101 indicate that this project contains and requires remediation/abatement of designated hazardous materials consisting of ACM. For bidding purposes, please describe the existing hazardous materials that will be disturbed or demolished as part of this project.
A: It is not expected that hazardous materials will be encountered in the work. If hazardous materials are discovered during removal operations, stop work and notify Architect and Owner;
mailto:erin.messing@alaska.gov hazardous materials include regulated asbestos containing materials, lead, PCB’s, and mercury.
Hazardous materials will be removed by Owner under a separate contract.
Q: The concrete slab on grade demolition scope is defined on Sheet AD100. Sheet Note 1 on Sheet M201 states “Install waste above floor from fixture to plumbing chase. Transition to below floor in chase.” There is no concrete slab demo work shown at the location where this note is called out, therefore is the intent for the new above ground waste lines to tie into an existing waste line before it transitions below the slab?
A: Yes, the intent is to tie into existing waste that transitions below the slab. The tie-in occurs above floor within the void of the chase.
Q: Sheet A100 indicates that DE-4 is Owner-furnished Owner-installed. However, DE-4 is drawn in dark linework therefore indicating Contractor-furnished Contractor-installed according to the Plan Legend. Please confirm that both DE-4’s are in fact Owner-furnished Owner-installed.
A: Confirmed. DE-4 is Owner-furnished and Owner-installed by the Owner’s dental equipment vendor.
Q: Sheet A100 indicates that D-1 is Owner-furnished Owner-installed. However, there is dark linework drawn in at the front and back of each D-1 indicating that some portion of the D-1 may be Owner-furnished Contractor-installed. For bidding purposes, please clarify the Contractor’s scope associated with both D-1’s.
A: The darker linework is still dashed – it indicates the full extents of the dental chair as operated through full range of motion. DE-1 is Owner-furnished and Owner-installed by the Owner’s dental equipment vendor. The Contractor will need to coordinate with this vendor to ensure that utilities serving the chair are in compliance with chair manufacturer’s installation guidelines to make ready for the equipment installation.
Q: According to Sheet A100, the PTD and SD are drawn in with dark dashed linework indicating Owner-furnished Contractor-installed. However, both of these items are listed products in the Finish Legend as if they may be the Contractor’s responsibility to also furnish. Please clarify.
A: PTD and SD are Owner-furnished/Contractor-installed. They are listed in the finish legend to define the design team’s assumptions for model/size/mounting height. Deviations from the assumed product typically necessitate a quick review to adjust mounting heights are required for fit with adjacent elements and dental equipment and accessible reach ranges.
Q: Sheet S001 lists “Dental equipment support and seismic attachment” under the Deferred Structural Submittals section of the General Structural Notes. Please confirm that any deferred submittal requirements associated with the dental equipment shall be provided by the Owner since such equipment is Owner-furnished Owner-installed. We would not be able to quote the costs for this engineering without detailed information on each dental equipment requiring such engineering.
A: Confirmed; any deferred submittal requirements associated with the dental equipment shall be provided by the Owner.
Q: Plan Keynote 7 on Sheet S100 states “Typical: steel ledger around perimeter of room per details.” Is this note referring to the steel stud/track ceiling? Because there are no structural steel ledgers called out anywhere except for at the steel bentplate at an isolated location above the new opening to be cut into the existing CMU wall. Please confirm there are no steel ledgers required for this project.
A: Yes, the steel ledger referenced in Keynote 7/S100 is the steel tracks attached to the CMU walls in details 1/S101 and 2/S101.
Q: Is the state accepting bids for just electrical or only from GC’s for the complete project?
A: Only GC’s for the complete project.
This addendum is considered part of the Invitation to Bid (ITB) and is to be acknowledged on your quote form.
Sincerely, Erin Messing Procurement Specialist IV cc:
Shawn Ratliff, Facilities Manager, DOC Michael Lim, Procurement Specialist V, DOC
End of Addendum
DATE NO. OF
SETS *TYPE* ADD/RPT
OTHER
POC:
PHONE: Email
POC:
PHONE: Email
POC:
PHONE: Email:
C (CONSULTANT)
6/19/2024
A (AGENCY) P (PLANROOM)
11001 Calaska Circle
Anchorage, AK
G (GENERAL)
COMPANY NAME: Roger Hickel Contracting
SP (SUPPLIER)
6/19/2024
Matt Helm
MAILING ADDRESS:
COMPANY NAME: Alaska Architectural Lighting
PHYSICAL ADDRESS:
Anchorage, AKPHYSICAL ADDRESS:
trohde@rhcak.com
6/19/2024
Tyler Rohde mhelm@akarchlight.com
COMPANY NAME: Consolidated Contracting & Engineering
Anchorage, AK
907-792-3514
MAILING ADDRESS:
ADVERTISING DATE: 6/18/2024
Dave Nickerson
907-279-1406
PHYSICAL ADDRESS: 2440 East Tudor Road #1139
PROJECT NAME: ACCW Dental Clinic Upgrade
PROJECT MANAGER: Shawn Ratliff
COMPANY/ADDRESS/PHONE/EMAIL
PROJECT NUMBER(S): 240005780
BID DUE DATE: 7/12/2024
S (SUBCONTRACTOR)
MAILING ADDRESS:
907-277-2966 consolidatedconeng@gmail.com
5401 Cordova Street afd: G:\Group\CONTRACTS\Facilities Contracts\Forms\Planholder List.xls As of: 7/24/2024 mailto:consolidatedconeng@gmail.com mailto:consolidatedconeng@gmail.com mailto:mhelm@akarchlight.com mailto:mhelm@akarchlight.com mailto:trohde@rhcak.com mailto:trohde@rhcak.com mailto:trohde@rhcak.com mailto:mhelm@akarchlight.com mailto:consolidatedconeng@gmail.com
DATE
ISSUED
NO. OF
SETS *TYPE* ADD/RPT
OTHER
POC:
PHONE: Email:
POC:
PHONE: Email
POC:
PHONE: Email
2820 Commercial Drive
907-759-5559
A (AGENCY) C (CONSULTANT) P (PLANROOM)
G (GENERAL) S (SUBCONTRACTOR) SP (SUPPLIER)
eburger@ravenelectric.com
6/20/2024
Erik Burger
PHYSICAL ADDRESS: 8015 Schoon Street Anchorage, AK
MAILING ADDRESS:
907-277-3200
COMPANY NAME: Raven Electric jackieg@criteriongeneral.com
6/19/2024
Jackie Graeber
PHYSICAL ADDRESS: Anchorage, AK
MAILING ADDRESS:
COMPANY NAME: Criterion General, Inc.
6/19/2024
Tristan Baranov
907-947-4134 tristan@arcticsales.net
PROJECT MANAGER: Shawn Ratliff ADVERTISING DATE: 6/18/2024
MAILING ADDRESS:
PHYSICAL ADDRESS: 12330 Old Glenn Hwy Eagle River, AK
COMPANY/ADDRESS/PHONE/EMAIL
BID DUE DATE: 7/12/2024
PROJECT NAME: ACCW Dental Clinic Upgrade PROJECT NUMBER(S): 240005780
COMPANY NAME: Arctic Sales afd: G:\Group\CONTRACTS\Facilities Contracts\Forms\Planholder List.xls As of: 7/24/2024 mailto:tristan@arcticsales.net mailto:tristan@arcticsales.net mailto:jackieg@criteriongeneral.com mailto:jackieg@criteriongeneral.com mailto:eburger@ravenelectric.com mailto:eburger@ravenelectric.com mailto:eburger@ravenelectric.com mailto:jackieg@criteriongeneral.com mailto:tristan@arcticsales.net
NO. OF
SETS *TYPE* ADD/RPT
OTHER
POC:
PHONE: Email:
POC:
PHONE: Email:
POC:
PHONE: Email:
907-561-5354
A (AGENCY) C (CONSULTANT) P (PLANROOM)
G (GENERAL) S (SUBCONTRACTOR) SP (SUPPLIER)
COMPANY NAME: AGC Online Plans agcplans@gmail.com
Elizabeth Carter
PHYSICAL ADDRESS: 8005 Schoon Street Anchorage, AK
MAILING ADDRESS:
MAILING ADDRESS:
907-315-3611 demaster.electric@gmail.com
Don DeMaster
PHYSICAL ADDRESS: 3525 E. Woodruff Lp Wasilla, AK
6/19/2024
6/19/2024 brie@plancenternw.com
COMPANY NAME: Demaster Electric, LLC
MAILING ADDRESS: PO Box 2486 Clackamas, OR
COMPANY/ADDRESS/PHONE/EMAIL
COMPANY NAME: Plan Center Northwest
Brie Kidwell
PHYSICAL ADDRESS: 6/19/2024
503-650-0148
PROJECT NAME: ACCW Dental Clinic Upgrade PROJECT NUMBER(S): 240005780
PROJECT MANAGER: Shawn Ratliff ADVERTISING DATE: 6/18/2024 BID DUE DATE: 7/12/2024 afd: G:\Group\CONTRACTS\Facilities Contracts\Forms\Planholder List.xls As of: 7/24/2024 mailto:brie@plancenternw.com mailto:brie@plancenternw.com mailto:demaster.electric@gmail.com mailto:demaster.electric@gmail.com mailto:agcplans@gmail.com mailto:agcplans@gmail.com mailto:agcplans@gmail.com mailto:demaster.electric@gmail.com mailto:brie@plancenternw.com
NO. OF
SETS *TYPE* ADD/RPT
OTHER
POC:
PHONE: Email
POC:
PHONE: Email
POC:
PHONE: Email
A (AGENCY) C (CONSULTANT) P (PLANROOM)
ADDENDA WILL BE MAILED TO THE ABOVE ADDRESSES OR DELIVERED VIA COURIER TO THE PHYSICAL ADDRESS - PLEASE BE SURE IT IS COMPLETE AND ACCURATE - FAILURE TO RECEIVE AND ACKNOWLEDGE AN ADDENDUM MAY RESULT IN THE PROPOSAL BEING DECLARED
NON-RESPONSIVE.
G (GENERAL) S (SUBCONTRACTOR) SP (SUPPLIER)
Jason Garner
PHYSICAL ADDRESS: 10400 E. Cody Drive Palmer, AK
MAILING ADDRESS:
907-746-1090
COMPANY NAME: Alaska Air Balancing
7/8/2024 jason@alaskaairbalancing.com
Aligned AK
6/19/2024 danielle@alignedak.com
Danielle Glenn
PHYSICAL ADDRESS: 9111 W. 8th Avenue Anchorage, AK
MAILING ADDRESS:
907-727-1103
COMPANY NAME:
Will Tompkins
PHYSICAL ADDRESS: 6517 Arctic Spur Road Anchorage, AK
MAILING ADDRESS:
COMPANY/ADDRESS/PHONE/EMAIL
COMPANY NAME: Sheet Metal, Inc.
6/24/2024
907-586-6909 wtompkins@sheetmetalinc.biz
PROJECT NAME: ACCW Dental Clinic Upgrade PROJECT NUMBER(S): 240005780
PROJECT MANAGER: Shawn Ratliff ADVERTISING DATE: 6/18/2024 BID DUE DATE: 7/12/2024 afd: G:\Group\CONTRACTS\Facilities Contracts\Forms\Planholder List.xls As of: 7/24/2024 mailto:wtompkins@sheetmetalinc.biz mailto:wtompkins@sheetmetalinc.biz mailto:danielle@alignedak.com mailto:danielle@alignedak.com mailto:jason@alaskaairbalancing.com mailto:jason@alaskaairbalancing.com mailto:jason@alaskaairbalancing.com mailto:danielle@alignedak.com mailto:wtompkins@sheetmetalinc.biz
NO. OF
SETS *TYPE* ADD/RPT
OTHER
POC:
PHONE: Email
POC:
PHONE: Email
POC:
PHONE: Email
**** SP (SUPPLIER)
MAILING ADDRESS:
907-575-7537
907-315-7031 randy@shermantechnologies.com
7/8/2024
ADDENDA WILL BE MAILED TO THE ABOVE ADDRESSES OR DELIVERED VIA COURIER TO THE PHYSICAL ADDRESS - PLEASE BE SURE IT IS COMPLETE AND ACCURATE - FAILURE TO RECEIVE AND ACKNOWLEDGE AN ADDENDUM MAY RESULT IN THE PROPOSAL BEING DECLARED
NON-RESPONSIVE.
MAILING ADDRESS:
907-347-1225 csiegfried@fullfordelectric.com
7/8/2024 bhyslip@airtest.us
MAILING ADDRESS:
Brandon Hyslip
PHYSICAL ADDRESS: 7/8/2024
Sherman Technologies
Charlie Siegfried
PHYSICAL ADDRESS: 303 E. Van Horn Road
Fairbanks, AK
COMPANY NAME: Airtest
Fullford Electric, Inc.
P (PLANROOM)
Randy Sherman
PHYSICAL ADDRESS: 5423 Fairbanks Street Anchorage, AK
G (GENERAL) S (SUBCONTRACTOR)
COMPANY NAME:
PROJECT NAME: ACCW Dental Clinic Upgrade PROJECT NUMBER(S): 240005780
PROJECT MANAGER: Shawn Ratliff ADVERTISING DATE: 6/18/2024 BID DUE DATE: 7/12/2024
COMPANY/ADDRESS/PHONE/EMAIL
COMPANY NAME:
C (CONSULTANT)A (AGENCY)
afd: G:\Group\CONTRACTS\Facilities Contracts\Forms\Planholder List.xls As of: 7/24/2024 mailto:csiegfried@fullfordelectric.com mailto:csiegfried@fullfordelectric.com mailto:bhyslip@airtest.us mailto:bhyslip@airtest.us mailto:randy@shermantechnologies.com mailto:randy@shermantechnologies.com mailto:randy@shermantechnologies.com mailto:csiegfried@fullfordelectric.com mailto:bhyslip@airtest.us
NO. OF
SETS *TYPE* ADD/RPT
OTHER
POC:
PHONE: Email
POC:
PHONE: Email
POC:
PHONE: Email
P149:179ROJECT NAME: ACCW Dental Clinic Upgrade PROJECT NUMBER(S): 240005780
PROJECT MANAGER: Shawn Ratliff ADVERTISING DATE: 6/18/2024 BID DUE DATE: 7/12/2024
COMPANY/ADDRESS/PHONE/EMAIL
COMPANY NAME: Trane
6/25/2024
Wanda Slavik
PHYSICAL ADDRESS: 7257 SW Kable Lane
Portland, OR
MAILING ADDRESS:
503-431-2539 wanda.slavik@trane.com
COMPANY NAME: Insulation Contractors of Alaska, LLC Joe Oathout
PHYSICAL ADDRESS: 165 E 56th Avenue Anchorage, AK
MAILING ADDRESS:
907-538-9082 joe@insulationcontractorsalaska.c
COMPANY NAME: The Plans Room
7/12/2024
907-563-2029 mail@theplansroom.com
7/11/2024
A (AGENCY) C (CONSULTANT) P (PLANROOM)
PHYSICAL ADDRESS:
ADDENDA WILL BE MAILED TO THE ABOVE ADDRESSES OR DELIVERED VIA COURIER TO THE PHYSICAL ADDRESS - PLEASE BE SURE IT IS COMPLETE AND ACCURATE - FAILURE TO RECEIVE AND ACKNOWLEDGE AN ADDENDUM MAY RESULT IN THE PROPOSAL BEING DECLARED
NON-RESPONSIVE.
G (GENERAL) S (SUBCONTRACTOR) SP (SUPPLIER)
MAILING ADDRESS:
afd: G:\Group\CONTRACTS\Facilities Contracts\Forms\Planholder List.xls As of: 7/24/2024 mailto:wanda.slavik@trane.com mailto:wanda.slavik@trane.com mailto:joe@insulationcontractorsalaska.com mailto:joe@insulationcontractorsalaska.com mailto:mail@theplansroom.com mailto:mail@theplansroom.com mailto:wanda.slavik@trane.com mailto:joe@insulationcontractorsalaska.com mailto:mail@theplansroom.com
NO. OF
SETS *TYPE* ADD/RPT
OTHER
POC:
PHONE: Email
POC:
PHONE: Email
POC:
PHONE: Email
PROJECT NAME: ACCW Dental Clinic Upgrade PROJECT NUMBER(S): 240005780
PROJECT MANAGER: Shawn Ratliff ADVERTISING DATE: 6/18/2024 BID DUE DATE: 7/12/2024
COMPANY/ADDRESS/PHONE/EMAIL
COMPANY NAME: Premier Electric
7/17/2024
Joel Florian
PHYSICAL ADDRESS: 5956 E. Shop Circle
Palmer, AK
MAILING ADDRESS:
907-748-0882 estimating@premierelectricak.com
COMPANY NAME: E.S. Constant Company Jackie Powell
PHYSICAL ADDRESS: 1072 NW Corporate Drive Troutdale, OR
MAILING ADDRESS:
503-255-7660 jackie@esconstant.com
COMPANY NAME:
7/17/2024
PHYSICAL ADDRESS:
MAILING ADDRESS:
ADDENDA WILL BE MAILED TO THE ABOVE ADDRESSES OR DELIVERED VIA COURIER TO THE PHYSICAL ADDRESS - PLEASE BE SURE IT IS COMPLETE AND ACCURATE - FAILURE TO RECEIVE AND ACKNOWLEDGE AN ADDENDUM MAY RESULT IN THE PROPOSAL BEING DECLARED
NON-RESPONSIVE.
G (GENERAL) S (SUBCONTRACTOR) SP (SUPPLIER)
A (AGENCY) C (CONSULTANT) P (PLANROOM)
afd: G:\Group\CONTRACTS\Facilities Contracts\Forms\Planholder List.xls As of: 7/24/2024 mailto:estimating@premierelectricak.com mailto:estimating@premierelectricak.com mailto:jackie@esconstant.com mailto:jackie@esconstant.com mailto:estimating@premierelectricak.com mailto:jackie@esconstant.com
Dustin McCleskey Line
Dustin McCleskey Line
Dustin McCleskey Line
Dustin McCleskey Line
Dustin McCleskey Line
Dustin McCleskey Line
Dustin McCleskey Line
Dustin McCleskey Line
Dustin McCleskey Line
Dustin McCleskey Line
Dustin McCleskey Line
Dustin McCleskey Line
Dustin McCleskey Line
Dustin McCleskey Line
Dustin McCleskey Callout
CONNECT TO EXISTING WASTE
Dustin McCleskey Callout
DEMOLISH VENT
Dustin McCleskey Callout
DEMOLISH WASTE TO SINK
INSTALLATION TECHNICIAN: TELEPHONE:
GENERAL NOTES & CONDITIONS (ALL TRADES)
SHEET TITLE
SHEET INDEX
EQUIPMENT SPECIALIST (E.S.): TELEPHONE:
DAVID SHEETS 458.221.0009
ANCHORAGE CORRECTIONAL
MANUFACTURER'S DENTAL CABINET DRAWINGS
SCV COVER SHEET
SA.0 DENTAL DRAWINGS
SED.1
SDC.1
DENTAL EQUIPMENT DETAILS
SCV
24 x 36N/A
COVER SHEET
PREPARED FOR:
1. DEFINITIONS
HENRY SCHEIN, HENRY SCHEIN INC., HENRY SCHEIN DENTAL, OR HSD INC. REFERS TO THE
EQUIPMENT SUPPLIER FOR THIS PROJECT ENGAGED BY THE OWNER UNDER A SEPARATE
CONTRACT.
E.S. - "EQUIPMENT & TECHNOLOGY SPECIALIST" IS A HENRY SCHEIN EMPLOYEE THAT
SPECIALIZES IN THE MANAGEMENT OF EQUIPMENT AND/OR TECHNOLOGY SALES AND
INSTALLATIONS AND HAS ASSISTED THE OWNER IN THE PREPARATION OF DRAWINGS AND
SPECIFICATIONS FOR THE CONSTRUCTION OF THE PROPOSED FACILITIES.
THE "GENERAL CONTRACTOR", ALSO KNOWN AS THE 'G.C.' IS REFERRED TO AS THE PERSON(S)
OR ENTITY WHO HAS ENTERED INTO A CONTRACTUAL AGREEMENT WITH THE OWNER FOR THE
WORK DEFINED IN SUCH AGREEMENT. THE G.C. IS RESPONSIBLE FOR ALL WORK CARRIED OUT
BY THEIR SUBCONTRACTORS OR SUBTRADES. IF THE CONSTRUCTION OF THE PROJECT IS LET
UNDER SEPARATE CONTRACTS BY THE OWNER, THE RESPONSIBILITIES STIPULATED BELOW
SHALL APPLY TO EACH CONTRACTOR.
THE "OWNER" IS REFERRED TO AS THE PERSON(S) OR ENTITY WHO OWNS OR LEASES THE
PREMISES FOR WHICH A CONSTRUCTION AGREEMENT HAS BEEN ENTERED UPON WITH THE
GENERAL CONTRACTOR. WHERE THE OWNER, AS REFERRED TO ABOVE, LEASES THE PREMISES
THE ENTITY WHO HAS OWNERSHIP OF THE PROPERTY WILL BE REFERRED TO AS THE LANDLORD.
THE "OWNER'S AGENT" IS A REPRESENTATIVE OF THE AGENT ACTING ON THEIR BEHALF AND
MAY HAVE THE AUTHORITY TO MAKE DECISIONS IN THEIR ABSENCE. THIS MAY BE AN OFFICE
MANAGER, AN ARCHITECT, AN ENGINEER, OR A PROJECT MANAGER HIRED BY THE OWNER.
2. DRAWINGS
THESE DRAWINGS ARE PREPARED BY HENRY SCHEIN AS DENTAL CONSULTANTS FOR ASSISTING
AN ARCHITECT/CONTRACTOR TO PRODUCE CONSTRUCTION DOCUMENTS & BUILD A DENTAL
OFFICE. THEY DO NOT CONSTITUTE A COMPLETE SET OF CONSTRUCTION DOCUMENTS. ITEMS
REQUIRED FOR BUILDING PERMITS OR CONSTRUCTION MAY NOT APPEAR ON THESE
DRAWINGS. IF THESE DRAWINGS ARE BEING SUBMITTED FOR BUILDING PERMIT, IT REMAINS THE
OWNER AND/OR GENERAL CONTRACTOR'S RESPONSIBILITY RETAIN THE PROPER
CONSULTANTS TO PREPARE COMPLETE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND
ELECTRICAL DRAWINGS.
DOOR SPECIFICATIONS, LIGHTING DESIGN, FINAL REFLECTED CEILING PLANS, AND OTHER
SPECIFICATIONS NOT COVERED IN THESE DRAWINGS ARE BY OTHERS.
RETENTION OF OTHER CONSULTANTS SUCH AS AN ARCHITECT, M.E.P. ENGINEERS, OR
SECURITY CONSULTANT, ARE THE RESPONSIBILITY OF THE OWNER AND/OR GENERAL
CONTRACTOR.
3. HENRY SCHEIN, INC. RESPONSIBILITIES
HENRY SCHEIN, INC. WILL ISSUE DETAILED DRAWINGS SHOWING CRITICAL LOCATIONS &
REQUIREMENTS OF ALL DENTAL-SPECIFIC EQUIPMENT. THE E.S. WILL BE AVAILABLE FOR
PERIODIC FIELD VISITS. VISITS WILL BE LIMITED TO A PRE-CONSTRUCTION ON-SITE MEETING, LAYOUT CHECKS AND INSTRUCTIONS TO THE VARIOUS TRADES IN THE CRITICAL ASPECTS OF
THE WORK PERTAINING TO DENTAL AND ALLIED EQUIPMENT. ALL REQUESTS FOR FIELD VISITS
SHALL ALLOW REASONABLE ADVANCED NOTICE. HENRY SCHEIN, INC. AND ITS
REPRESENTATIVES WILL NOT ASSUME ANY RESPONSIBILITIES FOR DEVIATIONS FROM THESE
DRAWINGS WITHOUT PRIOR WRITTEN CONSENT.
PRIOR TO CONSTRUCTION, THE E.S. WILL VERIFY THE SITE DIMENSIONS OF THE SPACE PRIOR TO
ENSURE THEY COINCIDE WITH THE DETAILED DRAWINGS. DURING CONSTRUCTION, THE E.S.
WILL CHECK THE JOBSITE PERIODICALLY AS REQUIRED. THE E.S. WILL BE AVAILABLE TO ASSIST
THE CONTRACTOR(S)AND THE OWNER IN THE INTERPRETATION OF THESE DRAWINGS AND
SPECIFICATIONS. PRIOR TO ENCLOSING WALLS, THE GENERAL CONTRACTOR AND/OR THE
FRAMING SUBCONTRACTOR IS REQUIRED TO COORDINATE WITH THE E.S. AND THE HENRY
SCHEIN INSTALLATION TECHNICIAN. THIS INSPECTION IS CRITICAL TO ENSURE THAT THE WALL
AND/OR CEILING SUPPORTS FOR DENTAL EQUIPMENT WILL MATCH WITH ANY CHANGES THAT
MAY HAVE OCCURRED WITH THE OWNER'S EQUIPMENT ORDER. IT IS THE RESPONSIBILITY OF
THE GENERAL CONTRACTOR TO HAVE PLUMBING, ELECTRICAL, SUPPORT BACKING, AND
LEAD INSTALLATION APPROVED BY MUNICIPAL INSPECTORS BEFORE POURING SLABS,
ENCLOSING PARTITIONS AND CEILING.
HENRY SCHEIN WILL NOT BE RESPONSIBLE FOR ANY UNFORESEEN CONDITIONS ARISING OUT
OF, OR DURING THE COURSE OF, CONSTRUCTION NOR FOR ANY DEVIATIONS FROM
DRAWINGS AND/OR SPECIFICATIONS WITHOUT PRIOR WRITTEN CONCENT.
EQUIPMENT INSTALLATION
A PRE-CONSTRUCTION MEETING IS REQUIRED WITH THE GENERAL CONTRACTOR, PLUMBER,
ELECTRICIAN, CABINET MAKER, AND THE E.S. ALL TEMPLATES CRITICAL TO EQUIPMENT
INSTALLATION WILL BE DISTRIBUTED AT THIS MEETING.
THE E.S. WILL INSPECT PREMISES PRIOR TO THE INSTALLATION OF ITS EQUIPMENT AT WHICH
TIME ALL FINISHES (CEILINGS, FLOORING, AND PAINTING) AND MECHANICAL WORK MUST BE
COMPLETED. RESPONSIBILITIES FOR THE INSTALLATION AND/OR HOOKUP OF DENTAL
EQUIPMENT WILL BE DEFINED IN THE SPECIFICATIONS FOR EACH TRADE. HENRY SCHEIN
DENTAL REQUIRES THAT ALL APPLICABLE TRADES BE REPRESENTED AT THE TIME OF
INSTALLATION.
4. GENERAL CONTRACTOR (G.C.) - RESPONSIBILITIES
ALL ITEMS LISTED OR NOTED HEREIN ARE FOR GUIDANCE ONLY AND DO NOT NECESSARILY
CONSTITUTE THE ENTIRE EXTENT OF THE WORK TO BE CARRIED OUT UNDER THE CONTRACT. THE
GENERAL CONTRACTOR IS RESPONSIBLE TO DEFINE AND PROVIDE ALL THE WORK REQUIRED
TO COMPLETE THIS PROJECT TO THE TRUE INTENT OF THE CONTRACT WHETHER OR NOT IT IS
SPECIFICALLY SHOWN OR SPECIFIED. WHERE THESE DOCUMENTS DO NOT PROVIDE ALL THE
INFORMATION NECESSARY FOR THE COMPLETE INSTALLATION OF ANY ITEM, THEN THE
MANUFACTURER'S INSTRUCTIONS FOR THE ITEM SHALL BE STRICTLY FOLLOWED.
THE GENERAL CONTRACTOR SHALL, SUPPLY AND INSTALL ALL ITEMS, ARTICLES, MATERIALS,
INCLUDE ALL LABOR, EQUIPMENT AND TOOLS NECESSARY TO COMPLETE THIS PROJECT AND
ALL SYSTEMS SHOWN. TEST AND VERIFY ALL EQUIPMENT INSTALLED UNDER THIS CONTRACT
AND INSTRUCT THE OWNER OR OWNER'S AGENT IN THE OPERATION OF THE EQUIPMENT.
THE G.C. SHALL THOROUGHLY FAMILIARIZE HIM/HERSELF WITH THE DRAWINGS,
SPECIFICATIONS, AND CONDITIONS COVERING THIS JOB. THE G.C. SHALL ADVISE THE OWNER
AND THE E.S. OF ANY CONFLICT BETWEEN THESE DRAWINGS AND THE FIELD CONDITIONS
BEFORE PROCEEDING WITH THE WORK.
THE G.C. SHALL COMPLY WITH ALL STATE AND MUNICIPAL LAWS, ORDINANCES, RULES, AND
REGULATIONS OF AUTHORITIES HAVING JURISDICTION. ALL WORK MUST MEET OR EXCEED THE
CURRENT BUILDING CODE UNDER THE JURISDICTION FOR WHICH THIS PROJECT IS LOCATED.
THE G.C. SHALL FILE ALL NECESSARY APPLICATIONS AND OBTAIN AND PAY FOR ALL PERMITS, AND CERTIFICATES OF APPROVAL PERTAINING TO THE CONSTRUCTION OF THE PREMISES, INCLUDING THE FINAL INSPECTION FOR OCCUPANCY PERMIT, UNLESS OTHERWISE STATED.
PERMITS OBTAINED SHALL INCLUDE THE CONNECTIONS TO ALL DENTAL EQUIPMENT AND
FIXTURES WHICH ARE TO BE COMPLETED BY THE GENERAL CONTRACTOR. HVAC, SPRINKLER
DRAWINGS, CORRESPONDING SPECIFICATIONS OR ANY OTHER DRAWINGS AND
SPECIFICATIONS THAT MAY BE REQUIRED FOR LICENSES AND PERMITS ARE TO BE PROVIDED BY OTHERS. HENRY SCHEIN INC. WILL NOT PROVIDE OR PAY FOR THESE SERVICES OR ANY OTHER
DRAWINGS AND SPECIFICATIONS THAT MAY BE REQUIRED FOR LICENSES AND PERMITS.
ALL MEASUREMENTS SHALL BE CHECKED AT THE JOB SITE. THE GENERAL CONTRACTOR SHALL
ASSUME ALL RESPONSIBILITY FOR THE ACCURACY OF FIELD MEASUREMENTS AND
CONDITIONS. THEY ARE ALSO RESPONSIBLE FOR THE PROPER MODIFICATIONS TO ANY
EXISTING, OR PREVIOUSLY INSTALLED WORK. WRITTEN APPROVAL MUST BE OBTAINED FROM
THE E.S. BEFORE ANY CHANGES AND/OR DEVIATIONS FROM DRAWINGS AND
SPECIFICATIONS ARE MADE.
THE G.C. SHALL ASSUME FULL RESPONSIBILITY FOR THE EXECUTION OF HIS/HER WORK AND FOR
ANY CHANGES AND/OR DEVIATIONS FROM DRAWINGS OR SPECIFICATIONS MADE WITHOUT
PRIOR WRITTEN APPROVAL FROM THE OWNER AND/OR THE E.S.. THE COST OF CORRECTIONS
RESULTING FROM CHANGES AND/OR DEVIATIONS SHALL BE BORNE BY THE GENERAL
CONTRACTOR.
A COMPLETE SET OF UP-TO-DATE DRAWINGS MUST BE KEPT AT THE JOB SITE AT ALL TIMES AND
ANY CHANGES MUST BE NOTED THEREON AND INITIALED.
THE CONTRACTOR SHALL INDEMNIFY AND HOLD HARMLESS THE OWNER AND THE OWNER'S
AGENT FROM AND AGAINST ALL CLAIMS FOR DAMAGE TO PERSON AND/OR PROPERTY
SUFFERED AS A RESULT OF THE PERFORMANCE OF WORK, WHETHER OR NOT, CAUSED BY
NEGLIGENCE, AND PAY ANY EXPENSES (INCLUDING, WITHOUT LIMITATIONS, ATTORNEY'S FEES, AND DISBURSEMENTS) INCURRED IN THE CONNECTION THEREWITH.
OTHER REQUIREMENTS
THE G.C. SHALL PARTICIPATE AT JOB COORDINATION MEETINGS WITH THE HENRY SCHEIN
REPRESENTATIVE AND ENSURE ATTENDANCE OF THE APPROPRIATE TRADES.
ALL TRADES SHALL DO THEIR OWN CUTTING. THE GENERAL CONTRACTOR SHALL DO ALL
PATCHING TO CONFORM TO MATERIAL, TEXTURE, AND SURFACE ALIGNMENT WITH THE
ADJOINING SURFACE AND FINAL TOUCH UP OF ALL FINISHED SURFACES.
THE GENERAL CONTRACTOR SHALL ENSURE THE PROTECTION OF ALL EQUIPMENT
FURNISHED UNDER HIS/HER CONTRACT AND BY OTHERS.
THE G.C. SHALL REVIEW ALL CUSTOM CABINETRY, SUCH AT THE RECEPTION DESK,
LABORATORY, AND STERILIZATION, WITH THE E.S. FOR ANY DENTAL EQUIPMENT
INCOPRORATION.
THE G.C. SHALL REMOVE ANY RUBBISH FROM THE CONSTRUCTION SITE AND ENSURE THAT ALL
PUBLIC SPACES ARE FREE OF CONSTRUCTION MATERIALS AND DEBRIS THROUGHOUT THE
DURATION OF THE CONTRACT. THE G.C. IS RESPONSIBLE FOR THE TOTAL CLEAN UP OF THE
JOB SITE UPON COMPLETION OF THEIR WORK.
THE GENERAL CONTRACTOR SHALL ISSUE A WRITTEN ONE-YEAR WARRANTY CERTIFICATE ON
ALL WORKMANSHIP AND MATERIALS FROM THE DATE OF OCCUPANCY, UNLESS NOTED
OTHERWISE IN THE CONSTRUCTION AGREEMENT BETWEEN THE OWNER AND THE G.C.. THIS
CERTIFICATE SHALL BIND THE GENERAL CONTRACTOR TO PROMPTLY CORRECT, REPAIR, OR
REPLACE, ANY DEFECTIVE EQUIPMENT OR WORKMANSHIP THAT WAS THE RESPONSIBILITY OF
THE G.C., WITHOUT COST TO THE OWNER.
5. SEPARATE CONTRACTS BY OWNER
THE OWNER RESERVES THE RIGHT TO PERFORM WORK RELATED TO THE PROJECT WITH
HIS/HER OWN FORCES, AND TO AWARD SEPARATE CONTRACTS IN CONNECTION WITH
OTHER PORTIONS OF THE PROJECT OR ON OTHER WORK ON THE SITE UNDER THESE OR
SIMILAR CONDITIONS OF CONTRACT. IF THE GENERAL CONTRACTOR CLAIMS THAT DELAY
OR ADDITIONAL COST IS INVOLVED BECAUSE OF SUCH ACTION BY THE OWNER, THE G.C.
MUST ENSURE THAT THEIR CLAIM WAS ORIGINALLY PART OF THEIR CONTRACT AGREEMENT.
THE G.C. SHALL AFFORD THE OWNER AND SEPARATE CONTRACTORS REASONABLE
OPPORTUNITY FOR THE INTRODUCTION AND STORAGE OF THEIR MATERIALS AND EQUIPMENT
AND THE EXECUTION OF THEIR WORK. THE G.C. SHALL CONNECT AND COORDINATE THEIR
WORK WITH OTHERS AS REQUIRED BY THE CONTRACT DOCUMENTS. ANY COSTS CAUSED BY
DEFECTIVE AND/OR ILL-TIME WORK SHALL BE BORNE BY THE PARTY RESPONSIBLE.
SEE OWNER OR OWNER'S AGENT FOR NON-DENTAL ITEMS AND AREAS NOT DETAILED IN
THESE DRAWINGS (SUCH AS RECEPTION, BUSINESS AREA, OFFICES, STAFF LOUNGE, STORAGE
ROOMS, OFFICE-WIDE SOUND SYSTEMS, CONTROLS, ETC.).
GENERAL NOTES
1. THESE DRAWINGS AND SPECIFICATIONS HAVE BEEN PRODUCED FOR THIS SPECIFIC PROJECT
ONLY, AND SHALL REMAIN THE EXCLUSIVE PROPERTY OF HENRY SCHEIN INC. THESE
DRAWINGS AND SPECIFICATIONS MAY NOT BE REPRODUCED OR USED FOR ANY OTHER
PURPOSE WITHOUT EXPRESSED WRITTEN CONSENT AND FULL PAYMENT OF ANY ASSOCIATED
FEES TO HENRY SCHEIN, INC.
2. ALL COMMUNICATIONS AND COORDINATION WITH TRADES SHALL BE THE RESPONSIBILITY OF
THE G.C. UNLESS STATED OTHERWISE IN THE CONTRACT AGREEMENT.
3. THE G.C. MUST SIGN THIS SHEET STIPULATING THAT HE/SHE UNDERSTANDS AND WILL COMPLY
WITH ALL SPECIFICATIONS BEFORE THE WORK WILL START. A SIGNED COPY OF THE PLANS
ARE TO BE RETURNED TO THE OWNER AND HENRY SCHEIN DENTAL.
4. IT IS THE RESPONSIBILITY OF A SUBCONTRACTOR TO READ AND UNDERSTAND ALL NOTES AND
ILLUSTRATIONS PERTAINING TO THEIR TRADE AND HOW THEIR WORK AFFECTS OTHER TRADES.
5. THE SUPPLY AND INSTALL OF THE CABINETS AND COUNTERTOPS, OTHER THAN THOSE
SPECIFIED AND/OR CONTRACTED BY HENRY SCHEIN, INC., IS THE RESPONSIBILITY OF THE
G.C..
6. THE OWNER SHALL MAKE ARRANGEMENTS FOR INSTALLATION OF NON-DENTAL SYSTEMS
UNDER A SEPARATE CONTRACT BEFORE WALLS ARE ENCLOSED.
7. ROUGH-IN AND FINISH WORK FOR DENTAL EQUIPMENT IS TO BE ACCORDING TO TEMPLATES
FURNISHED BY THE MANUFACTURERS OF EQUIPMENT BEING INSTALLED. THE E.S. WILL
POSITION THE TEMPLATES IN THEIR PROPER LOCATIONS, AT WHICH TIME ALL SPECIFICATIONS
ON THE PLANS WILL BE EXPLAINED TO THE GENERAL CONTRACTOR OR SUBCONTRACTOR(S).
ALL SPECIFIED SIZES OF PIPES, TUBING, FITTINGS, ETC., AS WELL AS PROPER HEIGHTS MARKED, MUST BE STRICTLY FOLLOWED. ANY DEVIATIONS ON SIZES OR HEIGHTS OF PIPES, TUBING, AND/OR FITTINGS MUST BE CORRECTED BEFORE THE EQUIPMENT CAN BE INSTALLED, AND
ANY SUCH EXTRA EXPENSE WILL BE THE RESPONSIBILITY OF G.C. AND/OR THE SUBTRADE.
8. THE G.C. SHALL SEAL ANY/ALL FLOOR AND FIRE PENETRATIONS MADE BY HENRY SCHEIN
INSTALLERS AT THE FINISHING STAGES WITH THE APPROPRIATE MATERIAL.
9. THE G.C. SHALL PROVIDE DOOR THRESHOLDS & DOOR SEALS NECESSARY FOR DENTAL
EQUIPMENT SOUND ATTENUATION.
10. THE GENERAL CONTRACTOR SHALL SUPPLY FASTENERS, ANCHORS, ACCESSORIES AND
ADHESIVES REQUIRED FOR FABRICATION AND ERECTION OF THE WORK. KEEP EXPOSED
FASTENERS TO A MINIMUM, NEATLY LAID OUT AND EVENLY SPACED. FLOOR FINISHES ARE TO
BE CONTINUOUS UNDERNEATH MILLWORK AND EQUIPMENT. TRANSITIONS AND VARIATIONS
BETWEEN FLOOR FINISHES TO BE SMOOTH AND LEVEL TO REDUCE INJURY WITH USE. PROVIDE
3/4'' (19MM) PLYWOOD SUPPORT BETWEEN STUDS FOR ALL WALLS TO SUPPORT UPPER
CABINETRY AND SHELVING, INCLUDING RECEPTION AND ALL TREATMENT ROOMS. WOOD
SUPPORTS ABOVE THE CEILING MAY NEED TO BE FIRE RATED, FOLLOW LOCAL CODES.
11. PRIOR TO POURING THE CONCRETE FLOOR AND ENCLOSING ALL WALLS, THE GENERAL
CONTRACTOR SHALL CONTACT THE E.S. AND INSTALLATION TECHNICIAN FOR FINAL
INSPECTION OF PLUMBING, ELECTRICAL AND WOOD SUPPORTS.
12. ALL LABOR AND MATERIAL NECESSARY FOR CHANGES IN EXISTING PLUMBING, CARPENTRY, AND ELECTRICAL WORK MUST BE DONE AND SUPPLIED BY THE GENERAL CONTRACTOR AND
IS NOT INCLUDED IN THE COST OF EQUIPMENT.
13. ALL PLUMBING AND ELECTRICAL LINES ARE TO BE CONCEALED UNLESS OTHERWISE
SPECIFIED.
14. THE ELECTRICAL PANEL SHALL BE CONVENIENT AND ACCESSIBLE, MEET ELECTRICAL CODE
REQUIREMENTS, AND BE LOCATED IN THE SUITE. LOCATION TO BE APPROVED BY THE OWNER
AND LANDLORD. THE G.C. SHALL REVIEW THE LOCATION WITH THE E.S., AS WELL AS THE
LOCATIONS OF THE TELEPHONE SYSTEM AND SERVER.
15. HENRY SCHEIN, INC. SHALL NOT BE HELD RESPONSIBLE FOR SUPPLYING UL/ULC OR CSA
APPROVAL CERTIFICATES. THE G.C. MAY CONTACT THE MANUFACTURER IF REQUIRED.
16. THE ELECTRICAL SUBCONTRACTOR SHALL PROVIDE SPECIFIED TERMINATION BOXES,
RECEPTACLES AND ANY HARDWIRE CIRCUITS LOCATED IN CUSTOM DENTAL CABINETRY.
THEY ARE ALSO RESPONSIBLE FOR SUPPLYING GFCI RECEPTACLES WHERE REQUIRED BY
CODE.
17. THE G.C. IS TO MAKE ARRANGEMENTS FOR TEMPORARY POWER AND/OR DISCONNECTION
OF ELECTRICAL AND MECHANICAL SYSTEMS IF AND WHEN REQUIRED.
18. IF MULTIMEDIA SYSTEMS, SUCH AS ENTERTAINMENT TVS, MONITORS, OR NETWORK COMPUTER SYSTEMS, OR SECURITY SYSTEMS ARE SUPPLIED AND INSTALLED BY HENRY SCHEIN, INC., THEN THESE SYSTEMS WILL BE THEIR RESPONSIBILITY. WHEN THESE SYSTEMS, OR OTHER SYSTEMS, ARE
NOT PROVIDED BY HENRY SCHEIN, INC., HENRY SCHEIN, INC. SHALL NOT BE HELD
RESPONSIBLE FOR THEIR INSTALLATION OR COMMISSIONING.
19. HENRY SCHEIN, INC. WILL ASSEMBLE EQUIPMENT AND, WHERE SPECIFIED WITHIN THESE
DRAWINGS, CONNECT TO UTILITIES PROVIDED, SUCH CONNECTIONS BY OTHER TRADES ARE
SUPPLIED CORRECTLY AND COMPLETELY (WITH PROPER SHUT-OFF VALVES/FITTINGS/
OUTLETS/TERMINATIONS). VERIFY ALL CONTRACTOR RESPONSIBILITIES FOR FINAL
CONNECTIONS WITH THESE DRAWINGS AND HENRY SCHEIN DENTAL E.S.. DIRECT ANY
QUESTIONS REGARDING CONTRACTOR RESPONSIBILITIES TO HENRY SCHEIN DENTAL E.S.
PRIOR TO CONSTRUCTION.
20. WHEN APPLICABLE, THE G.C. SHALL BE RESPONSIBLE FOR PROCURING A PLUMBING
SUB-CONTRACTOR THAT IS CERTIFIED TO INSTALL NITROUS OXIDE~OXYGEN CONSCIOUS
SEDATION SYSTEMS AS DETAILED IN THESE PLANS. HENRY SCHEIN DENTAL IS A NITROUS OXIDE
SYSTEM END USER COMPONENT SUPPLIER AND DOES NOT MANUFACTURE OR DESIGN ANY
OF THESE SYSTEMS. ANY SYSTEM DESIGN SHOWN ON THESE PLANS BY HENRY SCHEIN DENTAL
IS TO BE USED AS AN ILLUSTRATION ONLY FOR THE PURPOSE OF LOCATING END USER OUTLET
STATIONS, CYLINDER ROOM MANIFOLD, AND ALARM PANEL. THE FINAL TRUNK SYSTEM
INSTALLATION SHALL ADHERE TO THE MECHANICAL ENGINEERING DRAWINGS PREPARED BY
A THIRD PARTY.
21. PLUMBING SUBCONTRACTOR SHALL PROVIDE GAS CERTIFICATION CREDENTIALS IN
ACCORDANCE WITH ANY REQUESTS BY THE OWNER, GENERAL CONTRACTOR, BUILDING
DEPARTMENT, OR HENRY SCHEIN DENTAL PRIOR TO COMMENCING WORK IF ANY TYPE OF
NITROUS~OXIDE SYSTEM IS BEING INCORPORATED INTO THE PROJECT.
PRIOR TO POURING THE CONCRETE FLOOR AND
ENCLOSING ALL WALLS AND CEILINGS, THE
GENERAL CONTRACTOR SHALL CONTACT THE E.S.
AND INSTALLATION TECHNICIAN FOR FINAL
INSPECTION OF PLUMBING, ELECTRICAL AND
WOOD SUPPORTS.
-I M
PO
RT
A N
T N O
TE
TH
IS
D O
C
UM
EN
T
HA
S
BE
EN
P
RE
PA
RE
D A
S A
N
IN
ST
RU
M
EN
T O
F
PR
O
FE
SS
IO
N A
L
SE
RV
IC
E A
N D
IS
N
O T
A N
A
RC
HI
TE
C
TU
RA
L
PL
A
N
TH
E
ID
EA
S/ D
ES
IG
N
IN
C
LU
D
ED
H
ER
EI
N
A
RE
T
HE
S O
LE
P
RO
PE
RT
Y
O F
HE
N
RY
S
C
HE
IN
, I
N C
. A N
D A
RE
P
RO
TE
C
TE
D U
N D
ER
C
O
PY
RI
G
HT
TH
ES
E
PL
A N
S M
A Y
N O
T
BE
U
SE
D O
R
RE
PR
O
D
UC
ED
W
ITH
O
UT
E
XP
RE
SS
ED
W
RI
TT
EN
C O
N
SE
N T
O F
HE
N
RY
S
C
HE
IN
, I
N C
A
N D
F
UL
L
PA
YM
EN
T O
F A
N Y
A
SS
O C
IA
TE
D D
ES
IG
N F
EE
S.
A
LL
D
IM
EN
SI
O N
S A
RE
S
UB
JE
C T
TO
J
O B-
SI
TE
V
ER
IF
IC
A
TIO
N
REVISIONS:
HENRY SCHEIN REP:
PR
O
JE
C
T:
LO
C
A
TIO
N
SCALE: SHT. SIZE:
INT.SQ.FT.=
2023 by HENRY SCHEIN, INC.c
REGION:
PHONE #:
PROJECT START DATE:
FINALS START DATE:
DRAWN BY:
FINALS BY:
CHECKED BY:
PROJECT NUMBER:
P:
\_A
LL
R
EG
IO
NS
\O
R Or eg on
-A las ka \A nc ho ra ge
C or re cti on al\
An ch or ag e C or re cit on al-
1I- D
W
L
IN
C O
LN
A
V E, W
ES
T A
LL
IS
, W I he nr ys ch ei ni nt eg ra te d d es ig n.
co m
H
EN
RY
SC
H
EI
N
R
IN
TE
G
RA
TE
D
D
ES
IG
N
S
TU
D
IO
A N
C H
O R
A G
E C
O R
R E
C T
IO
N
A L
N
C
HO
RA
G
E, A
K
DAVID SHEETS
OR/AK - OREGON
458.221.0009
03/01/2022
04/03/2023
ARCH
KH
AKL
PER ARCH
22-0516
BELOW -
COUNTER
STERILIZER
TRE.
ROOM
TRE.
ROOM
TRE.
ROOM
TRE.
ROOM
2A
3A
9 9A
9B
2A
3A
4A 4A
99A
9B
14A15 15B
PLEASE NOTE: A LICENSED CONTRACTOR IS RESPONSIBLE FOR PROVIDING
EQUIPMENT BLOCKING AND ALL REQUIRED UTILITIES. ALL REQUIREMENTS TO BE
VERIFIED BY MANUFACTURER'S SPEC SHEETS PROVIDED BY HENRY SCHEIN DENTAL
EQUIPMENT SPECIALIST. MANUFACTURER'S SPECS SUPERSEDE ANY AND ALL
INFORMATION CONTAINED HEREIN.
GENERAL SPECIFICATIONS
Q
UA
N
TIT
Y
SP
EC
. N
UM
BE
R
DESCRIPTION C
O
LD
W
A
TE
R
HO
T W
A
TE
R D
RA
IN
C O
M
PR
ES
SE
D A
IR
N
A
TU
RA
L
G A
S V
A C
UU
M
N 2O
O
XY
G
EN
N
ITR
O G
EN
V
EN
T
PO
W
ER
D
ED
IC
A
TE
D
C
IR
C
UI
T
LO
W
V O
LT
A
G E
C O
N
TR
O L
D A
TA
D
RO
P
UTILITIES
D
ET
A
IL
2A
3A
4A
9A
9B
14A
15B
UTILITY CENTER – SELF-CONTAINED WATER. SEE DETAIL(S). SELF-CONTAINED WATER. ALL
UTILITIES MUST CONFORM TO PREVAILING LOCAL CODES.
UTILITY CENTER - SELF-CONTAINED WATER. SEE DETAIL(S). ALL UTILITIES MUST CONFORM TO
PREVAILING LOCAL CODES.
2" SUB-FLOOR CONDUIT - SUB-FLOOR PIPE CHASE WITH PULL-STRING SUPPLIED & INSTALLED BY
ELECTRICIAN. SWEEPING 90 DEGREE BENDS ONLY. STUB-UP FLUSH WITH SUB-FLOOR AT EACH
END, MARK LOCATION AT FINISH.
DENTAL TRACK LIGHT - SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. BLOCKING AND
ELECTRICAL BY CONTRACTOR(S).
WALL MOUNTED INTRAORAL X-RAY HEAD, ARM, AND WALL BRACKET - SUPPLIED AND
INSTALLED BY HENRY SCHEIN DENTAL. BLOCKING & ELECTRICAL BY CONTRACTOR(S).
X-RAY MASTER CONTROL – SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. ELECTRICIAN TO SUPPLY AND INSTALL PIPE CHASE WITH PULL-STRING TO (9) LOCATION WHEN (9A) IS REMOTE.
VERIFY SUPPLIER OF WIRING WITH HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST.
X-RAY REMOTE EXPOSURE BUTTON – SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL.
ELECTRICIAN TO SUPPLY AND INSTALL PIPE CHASE WITH PULL-STRING TO (9A) OR (9C)
LOCATION. VERIFY SUPPLIER OF EXPOSURE BUTTON AND WIRING WITH HENRY SCHEIN DENTAL
EQUIPMENT SPECIALIST.
STERILIZER (AUTOCLAVE) - SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. POWER BY
ELECTRICIAN.
ULTRASONIC CLEANER - SUPPLIED AND INSTALLED BY HENRY SCHEIN DENTAL. UTILITIES BY
CONTRACTOR(S).
HANDPIECE MAINTENANCE SYSTEM - CONTRACTOR(S) TO PROVIDE REQ'D UTILITIES. 1/2" AIR
LINE WITH 1/4” ANGLE VALVE (ABOVE COUNTERTOP). SYSTEM SUPPLIED AND INSTALLED BY
HENRY SCHEIN DENTAL.
115V
115V
115V
115V
115V
115V
115V
20A
20A
2A
3A
4A
9B
14A
15B
SA.0
24 x 361/4"=1'-0"
DENTAL
DRAWINGS
NEW REINFORCEMENT PLACED FOR
CEILING-MOUNTED EQUIPMENT. SEE
"REINFORCEMENT SPECIFICATION SCHEDULE"
FOR MORE INFORMATION.
NEW REINFORCEMENT PLACED FOR WALL-
MOUNTED EQUIPMENT. SEE
"REINFORCEMENT SPECIFICATION
SCHEDULE" FOR MORE INFORMATION.
NEW WALLS TO BE CONSTRUCTED
WALL LEGEND
2. VERIFY ALL DIMENSIONS WITH HENRY SCHEIN DENTAL REP. ON
JOBSITE. ON SITE MODIFICATIONS MAY NEED TO BE DONE BY
CONTRACTOR, BUT SHOULD BE VERIFIED BY ALL PARTIES INVOLVED.
3. USE 5/8" GYPSUM WALLBOARD THROUGHOUT THE OFFICE TO
PROVIDE EXTRA PROTECTION AGAINST X-RAY SCATTER RADIATION.
1. THIS SPECIFICATION SHEET IS INTENDED AS A GUIDE FOR TRADESMEN.
THE FLOOR PLANS ENCLOSED HEREIN ARE SUGGESTIONS FOR THE
PLACEMENT OF DENTAL EQUIPMENT. THEY ARE NOT INTENDED FOR
CONSTRUCTION.
CONSTRUCTION NOTES
DIMENSIONS AND REINFORCEMENT SPECIFICATIONS
PROPOSED FLOOR PLAN
DENTAL SPECIFICATIONS
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
*SPECIFICATIONS MAY INCLUDE DATA, SEE ELECTRICAL
SCHEDULE THIS SHEET
SEE SHEET SED.1 FOR DENTAL EQUIPMENT DETAILS
VACUUM NOTES
THE VACUUM PIPING LAYOUT HAS A LARGE EFFECT ON THE EFFICIENCY
AND RELIABILITY OF THE DENTAL VACUUM SYSTEM. REFER TO
MANUFACTURER'S PRE-INSTALLATION GUIDE PROVIDED BY HENRY
SCHEIN EQUIPMENT SPECIALIST FOR SPECIFIC SIZING OF STUB-UP,
TRUNK, AND BRANCH LINES.
IT IS HIGHLY RECOMMENDED THAT VACUUM LINES RUN UNDERNEATH
DENTAL EQUIPMENT BY MEANS OF TRENCHING/ CORING (CONCRETE
SLAB) OR IN SUB FLOOR (BASEMENT/ CRAWL SPACE). ALL LINES ARE TO
BE DESIGNED WITH PVC PIPING UNLESS DICTATED BY LOCAL CODES TO
USE COPPER OR CAST IRON.
TO ENSURE OPTIMUM VACUUM PERFORMANCE, INSTALL MAIN LINE
DIRECTLY BELOW THE DENTAL CHAIR, CABINET OR WALL JUNCTION
BOX TO REDUCE OR ELIMINATE BRANCH LINE RUNS WHEREVER
POSSIBLE.
I. TERMINATION
TERMINATE VACUUM TRUNK LINE IN MECHANICAL ROOM. PLUMBING
CONTRACTOR TO PROVIDE FPT ADAPTOR ON END OF STUB-UP FROM
FLOOR OR WALL. SIZE OF ADAPTOR TO BE DETERMINED BY TRUNK AND
PUMP INTAKE PIPE SIZES. SEE DETAILS THIS SET & MANUFACTURER
TEMPLATES PROVIDED BY HENRY SCHEIN EQUIPMENT REP. IN THE CASE
OF DUAL TRUNK LINE SYSTEM, PROVIDE ENOUGH SPACE BETWEEN
STUB-UPS TO INSTALL TEES ON BOTH LINES.
2. TRUNK LINE(S)
VACUUM TRUNK LINES(S) TO BE SUPPORTED EVERY 6'-0" TO PREVENT
SAG AND SLOPED A MINIMUM OF 1/4" PER 10'-0" TOWARD THE
VACUUM PUMP.
3. BRANCH LINE(S)
BRANCH LINES ARE TO HAVE "SWEEPING" 90 DEGREE TURNS TO AVOID
VACUUM LOSS. A "WYE" FITTING SHOULD BE USED TO JOIN BRANCH
LINES TO THE TRUNK LINE.
SPECIAL NOTE:
IF VACUUM LINES ENCROACH ON EITHER A WALL OR COLUMN
FOOTING, USE 45 DEGREE ELBOWS TO PIPE AROUND FOOTING SO PIPE
REACHES PROPER LOCATION.
WYE FITTING
MAIN LINE
45 ELBOWS
BRANCH LINE CONFIGURATION
SUB FLOOR
FLOW
PUMP
TO
FLOW
DO NOT PIPE TRUNK LINE IN A SERIES
MANNER LOOPING FROM J-BOX TO
J-BOX. A CONTINUOUS TRUNK LINE MUST
BE MAINTAINED FROM THE PUMP TO THE
FURTHEST J-BOX USING BRANCH LINES
OFF OF THE TRUNK LINE TO PICK UP EACH
VACUUM OUTLET. TRUNK LINE MAY
FOLLOW DRAIN LINE TRENCHES WITHIN
REASON. USE ONLY 45 DEGREE EL'S. DO
NOT USE ANY 90 DEGREE EL'S. ALL SUB
FLOOR SCH 40 PVC CONNECTIONS ARE
TO BE PLUMBED WITH 45 DEGREE EL'S
USING DETAIL A FOR TEEING BRANCH
LINE CONNECTIONS INTO TRUNK LINE.
DETAIL A
WYE FITTING (USE FOR ALL SUB
FLOOR INTERSECTIONS)
ELECTRICAL NOTES
5. ADDITIONAL CONVENIENCE OUTLETS REQUIRED ON JOBSITE ARE THE
RESPONSIBILITY OF ELECTRICAL CONTRACTORS. FOLLOW LOCAL CODE
RESTRICTIONS.
4. GFCI PROTECTION OR REDUNDANT GROUND IN DENTAL CHAIR
RECEPTACLES, DENTAL UTILITY CABINETS AND ANY OTHER AREAS
REQUIRED BY LOCAL CODE IS THE RESPONSIBILITY OF THE ELECTRICAL
CONTRACTOR.
2. EXACT EQUIPMENT LOCATIONS MUST BE JOB SITE VERIFIED BY THE
HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST.
3. FOLLOW MANUFACTURER'S TEMPLATES FOR EXACT REQUIREMENTS
FOR ANY EQUIPMENT SUPPLIED BY HENRY SCHEIN DENTAL. CONSULT
WITH HENRY SCHEIN DENTAL REP FOR ADDITIONAL INFORMATION.
1. THIS SPECIFICATION SHEET IS INTENDED AS A GUIDE FOR TRADESMEN.
THE FLOOR PLANS ENCLOSED HEREIN ARE SUGGESTIONS FOR THE
PLACEMENT OF DENTAL EQUIPMENT. THEY ARE NOT INTENDED FOR
CONSTRUCTION.
7. ALL COMPUTER NETWORKING AND WORKSTATIONS MUST BE
SPECIFIED BY CUSTOMER'S COMPUTER SUPPLIER. IF HENRY SCHEIN WILL
BE SUPPLYING THE COMPUTERS & NETWORKING COMPONENTS, SEE
SHEET SE.2 FOR THE OFFICE TECHNOLOGY PLAN.
8. CONTRACTOR TO PROVIDE AND INSTALL ALL EXIT SIGNS, EMERGENCY
LIGHTING AND FIRE SUPPRESSION & DETECTION SYSTEMS AS PER
ARCHITECT'S DRAWINGS AND LOCAL CODE.
9. REFER TO ARCHITECT'S DRAWINGS FOR ELECTRICAL REQUIREMENTS IN
ALL AREAS NOT INDICATED ON THIS PLAN.
ALL DIMENSIONS NOTED ON PLAN ARE TO THE CENTERLINE
OF RECEPTACLE OR UTILITY CENTER
(UNLESS SHOWN OTHERWISE)
6. ALL CONDUIT LOCATIONS SHOULD BE VERIFIED WITH OWNER AND
HENRY SCHEIN REP PRIOR TO ROUGH-IN.
PO
RT
A N
T N O
TE
TH
IS
D O
C
UM
EN
T
HA
S
BE
EN
P
RE
PA
RE
D A
S A
N
IN
ST
RU
M
EN
T O
F
PR
O
FE
SS
IO
N A
L
SE
RV
IC
E A
N D
IS
N
O T
A N
A
RC
HI
TE
C
TU
RA
L
PL
A
N
TH
E
ID
EA
S/ D
ES
IG
N
IN
C
LU
D
ED
H
ER
EI
N
A
RE
T
HE
S O
LE
P
RO
PE
RT
Y
O F
HE
N
RY
S
C
HE
IN
, I
N C
. A N
D A
RE
P
RO
TE
C
TE
D U
N D
ER
C
O
PY
RI
G
HT
TH
ES
E
PL
A N
S M
A Y
N O
T
BE
U
SE
D O
R
RE
PR
O
D
UC
ED
W
ITH
O
UT
E
XP
RE
SS
ED
W
RI
TT
EN
C O
N
SE
N T
O F
HE
N
RY
S
C
HE
IN
, I
N C
A
N D
F
UL
L
PA
YM
EN
T O
F A
N Y
A
SS
O C
IA
TE
D D
ES
IG
N F
EE
S.
A
LL
D
IM
EN
SI
O N
S A
RE
S
UB
JE
C T
TO
J
O B-
SI
TE
V
ER
IF
IC
A
TIO
N
REVISIONS:
HENRY SCHEIN REP:
PR
O
JE
C
T:
LO
C
A
TIO
N
SCALE: SHT. SIZE:
INT.SQ.FT.=
2023 by HENRY SCHEIN, INC.c
REGION:
PHONE #:
PROJECT START DATE:
FINALS START DATE:
DRAWN BY:
FINALS BY:
CHECKED BY:
PROJECT NUMBER:
P:
\_A
LL
R
EG
IO
NS
\O
R Or eg on
-A las ka \A nc ho ra ge
C or re cti on al\
An ch or ag e C or re cit on al-
1I- F
W
L
IN
C O
LN
A
V E, W
ES
T A
LL
IS
, W I he nr ys ch ei ni nt eg ra te d d es ig n.
co m
H
EN
RY
SC
H
EI
N
R
IN
TE
G
RA
TE
D
D
ES
IG
N
S
TU
D
IO
A N
C H
O R
A G
E C
O R
R E
C T
IO
N
C
HO
RA
G
E, A
K
DAVID SHEETS
OR/AK - OREGON
458.221.0009
03/01/2022
04/03/2023
ARCH
KH
AKL
PER ARCH
22-0516
PLUMBING NOTES
5. WATER PRESSURE MUST NOT EXCEED 50 PS1 AT ALL DENTAL UNITS.
6. ALL PLUMBING MUST CONFORM TO LOCAL PREVAILING CODES.
3. FOLLOW MANUFACTURER'S TEMPLATES FOR EXACT REQUIREMENTS
FOR ANY EQUIPMENT SUPPLIED BY HENRY SCHEIN DENTAL. CONSULT
WITH HENRY SCHEIN DENTAL REP FOR ADDITIONAL INFORMATION.
1. THIS SPECIFICATION SHEET IS INTENDED AS A GUIDE FOR TRADESMEN.
THE FLOOR PLANS ENCLOSED HEREIN ARE SUGGESTIONS FOR THE
PLACEMENT OF DENTAL EQUIPMENT. THEY ARE NOT INTENDED FOR
CONSTRUCTION.
2. EXACT EQUIPMENT LOCATIONS MUST BE JOB SITE VERIFIED BY THE
HENRY SCHEIN DENTAL EQUIPMENT SPECIALIST.
7. REFER TO ARCHITECT'S DRAWINGS FOR PLUMBING REQUIREMENTS IN
ALL AREAS NOT INDICATED ON THIS PLAN.
ALL DIMENSIONS NOTED ON PLAN ARE TO THE CENTERLINE
OF PLUMBING OR UTILITY CENTER
(UNLESS SHOWN OTHERWISE)
4. DENTAL AIR IS SUPPLIED THROUGH USE OF A DENTAL AIR
COMPRESSOR/SUPPLY SYSTEM AND IS PERMITTED TO BE USED AS A
SUPPORT GAS FOR DRIVING DENTAL TOOLS AND SUPPLYING AIR-DRIVEN
EQUIPMENT AS DESCRIBED WITHIN NFPA 99. DENTAL AIR IS NOT A
MEDICAL GAS.
THIS PLAN IS FOR THE SOLE PURPOSE OF SPECIFICATION AND
INSTALLATION OF THE DENTAL EQUIPMENT SUPPLIED BY HENRY
SCHEIN DENTAL. THE SPACE PLANNING AND CONCEPTUAL
DESIGN HAS BEEN PROVIDED BY OTHERS AND THE IDEAS
HEREIN ARE NOT NECESSARILY RECOMMENDED BY THE HENRY
SCHEIN INTEGRATED DESIGN STUDIO .TM
DENTAL CHAIR AND CABINET UTILITIES TO BE LOCATED ON
JOB-SITE PER MANUFACTURER'S TEMPLATES. LOCATIONS TO
BE APPROVED BY DOCTOR AND HENRY SCHEIN EQUIPMENT
SPECIALIST PRIOR TO ROUGH-IN.
ALL NEW TREATMENT ROOM UTILITIES TO BE TIED INTO EXISTING
DENTAL MECHANICAL SYSTEMS. SEE HENRY SCHEIN REP.
AutoCAD SHX Text 2'-6"
AutoCAD SHX Text 2'-6"
AutoCAD SHX Text 2'-3"
AutoCAD SHX Text 2'-3"
AutoCAD SHX Text 10"
AutoCAD SHX Text 10"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
NOTES:
1. DETAIL PROVIDED FOR UTILITY REQUIREMENTS.
REFER TO MANUFACTURER'S INSTALLATION GUIDE
FOR ADDITIONAL INFORMATION. HENRY SCHEIN
DENTAL EQUIPMENT SPECIALIST WILL PROVIDE
INSTALLATION TEMPLATE UPON REQUEST.
2. INSTALLATION MUST CONFORM TO ALL LOCAL
ELECTRICAL AND PLUMBING CODES.
3. ALL UTILITIES HEREIN TO BE SUPPLIED & INSTALLED BY
LICENSED CONTRACTORS. FINAL CONNECTIONS
TO EQUIPMENT BY HENRY SCHEIN DENTAL.
4. ALL UTILITIES MUST BE NO HIGHER THAN 4 14" A.F.F.
AT FINISH.
5. ALL PLUMBED SYSTEMS MUST BE FLUSHED CLEAN OF
ANY DEBRIS PRIOR TO EQUIPMENT INSTALLATION.
2A A-DEC 411 CHAIR UTILITIES
NOT TO SCALE
TOP VIEW
CL
COMPRESSED AIR: 1/2" SUPPLY LINE FROM COMPRESSOR BY PLUMBER. STUB-UP FROM FLOOR 1”-2”.
TERMINATE WITH 3/8” ANGLE VALVE. PRESSURE 100 PSI MAX.
ELECTRICAL: TWO GANG BOX & 115V DUPLEX OUTLET BY ELECTRICIAN. CHAIR MAX DRAW: 10A
CHASE: GRAY ELECTRICAL PVC PIPE CHASE WITH PULL-STRING BY ELECTRICIAN (SEE SHEET SE.1 FOR SIZE & LOCATIONS). 6" MIN. RADIUS FOR ALL BENDS. STUB-UP FLUSH WITH SUB-FLOOR, MARK LOCATION AT FINISH.
TOE OF CHAIR
C L
HEAD OF CHAIR
UTILITY CENTER FRAME
E
A
C
A
E
C
C
A V
MANUFACTURER PROVIDED
JUNCTION BOX & QUAD
OUTLET (APPROX.
LOCATION AND
ORIENTATION)
NOTES:
1. DETAIL PROVIDED FOR UTILITY REQUIREMENTS.
REFER TO MANUFACTURER'S INSTALLATION GUIDE
FOR ADDITIONAL INFORMATION. HENRY SCHEIN
DENTAL REP WILL PROVIDE INSTALLATION TEMPLATE
UPON REQUEST.
2. INSTALLATION MUST CONFORM TO ALL LOCAL
ELECTRICAL AND PLUMBING CODES.
3. ALL UTILITIES HEREIN TO BE SUPPLIED & INSTALLED BY
LICENSED CONTRACTORS. FINAL CONNECTIONS
TO EQUIPMENT BY HENRY SCHEIN DENTAL.
4. ALL VALVES, BOXES AND PIPES FROM FLOOR MUST
BE NO HIGHER THAN 5" A.F.F.
5. ALL PLUMBED SYSTEMS MUST BE FLUSHED CLEAN OF
ANY DEBRIS PRIOR TO EQUIPMENT INSTALLATION.
3A ADEC 5580 CABINET UTILITIES
NOT TO SCALE
TOP VIEW (FLOOR OPTION)
COMPRESSED AIR: 1/2" SUPPLY LINE FROM COMPRESSOR BY PLUMBER. STUB-UP FROM FLOOR 1”-2”.
TERMINATE WITH 3/8” ANGLE VALVE. PRESSURE 100 PSI MAX.
ELECTRICAL: 16" ELECTRICAL WHIP TERMINATED PER CODE FOR CONNECTION TO MANUFACTURER
PROVIDED JUNCTION BOX.
CHASE: GRAY ELECTRICAL PVC PIPE CHASE WITH PULL-STRING BY ELECTRICIAN (SEE SHEET SE.1 FOR SIZE & LOCATIONS). 6" MIN. RADIUS FOR ALL BENDS. STUB-UP FLUSH WITH SUB-FLOOR, MARK LOCATION AT FINISH.
CENTRAL VACUUM: 1/2" COPPER BRANCH LINE RISER BY PLUMBER. TERMINATE 1-2" A.F.F.
A
E
C
V
ELEVATION VIEW (WALL OPTION)
UTILITIES TO BE RUN IN
FLOOR OR WALL BASED
ON SITE CONDITIONS
CL
A
V
UTILITIES TO STUB-OUT
FROM WALL 6" (MIN.)
FINISHED
FLOOR
16" ELECTRICAL
WHIP TO EXTEND
FROM STUB-OUT
FOR HOOK-UPS
CL
E
BACK OF CABINET
COUNTERTOP ABOVE
E
C
4A SUB-FLOOR CHASE
NOT TO SCALE
FOLLOW LOCAL CODES FOR ALL WORK.
TERMINATE CONDUIT IN BASE OF
REAR CABINET OR IN WALL. SEE
REAR CABINET DETAIL. COORDINATE
WITH HENRY SCHEIN REP.
2" CONDUIT - PIPE CHASE WITH
PULL-STRING SUPPLIED AND
INSTALLED BY CONTRACTOR. 6"
MIN. SWEEPING BENDS. STUB-UP
FLUSH WITH SUB-FLOOR, MARK
LOCATION OF PIPE AT FINISH.
SEE CHAIR/CABINET/CART UTILITY
CENTER DETAIL FOR CONDUIT
TERMINATION LOCATION.
COORDINATE WITH HENRY SCHEIN REP.
PRODUCT SPECIFICATIONS
1 - 5A 60-120
NOTES:
1. DETAIL PROVIDED FOR BLOCKING & UTILITY
REQUIREMENTS. REFER TO MANUFACTURER'S
INSTALLATION GUIDE FOR ADDITIONAL
INFORMATION.
2. INSTALLATION MUST CONFORM TO ALL LOCAL
FRAMING AND ELECTRICAL CODES.
3. PROVIDE ADEQUATE BLOCKING AND STRUCTURAL
BRACING TO SUPPORT A PULL OF 500 LBS.
BLOCKING MUST BE LEVEL.
4. MOUNTING MATERIALS SUPPLIED AND INSTALLED BY
CONTRACTOR.
5. FINAL CONNECTIONS TO BE MADE BY HENRY
SCHEIN DENTAL.
NOMINAL VAC RATING
VOLTAGE MIN/MAX
FULL LOAD AMPS
WEIGHT (LBS)
108/132
SUPPORT STRUCTURE AND BRACING SPECIFIED BY
ENGINEER, SUPPLIED AND INSTALLED BY CONTRACTOR.
FINISHED CEILING
6 TYPICAL TRACK MOUNTED DENTAL LIGHT
NOT TO SCALE
TRACK LIGHT PALETTE, SUPPLIED
AND INSTALLED BY HENRY SCHEIN
DENTAL AT FINISH.
FRONT VIEW
SIDE VIEW
BLOCKING - SINGLE 2x12, CUT TO SIZE OF PLYWOOD
PALETTE SHIPPED WITH TRACK LIGHT. SEE HENRY SCHEIN
REP. MOUNT FLUSH WITH FINISHED CEILING. REINFORCE
WITH 2x4 STUDS ON BOTH SIDES. FOR
NON-COMBUSTABLE CONSTRUCTION, FRT LUMBER MAY
BE USED OR BLOCKING MAY BE WRAPPED IN FIRECODE
CORE GYP. BRD. FOLLOW LOCAL CODES. BACKING
MUST BE LEVEL
ELECTRICIAN TO PROVIDE JUNCTION BOX
& 115V POWER FEED WITH 6' WHIP ABOVE
CEILING FOR TRACK LIGHT. SEE HENRY
SCHEIN REP FOR FINAL TERMINATION
POINT, DRILL HOLE & FEED WHIP THROUGH
BACKING INTO TRACK LIGHT FOR FINAL
CONNECTIONS.
9 PROGENY PREVA X-RAY
NOT TO SCALE
FOLLOW LOCAL CODES FOR ALL WORK.
DETAIL PROVIDED FOR BLOCKING & UTILITY
REQUIREMENTS. REFER TO MANUFACTURER'S
INSTALLATION GUIDE FOR ADDITIONAL
INFORMATION.
THE WALL FABRICATION AND ATTACHMENTS TO
THE BUILDING STRUCTURE MUST BE CAPABLE OF
WITHSTANDING A LOAD MOMENT OF 850 FT. LBS.,
100 LB. SHEAR LOAD AND A 500 LB. WITHDRAWAL
FORCE AT EACH OF THE MOUNTING BOLTS.
FRAMING SHOULD ALLOW ALL FOUR MOUNTING
BOLTS TO ENTER SOLID WOOD. MOUNTING
MATERIALS SUPPLIED AND INSTALLED BY
CONTRACTOR.
STACKED 2 x 4 OPTION (TOP VIEW)
1/2" OR 5/8" PLYWOOD
(BASED ON FRAMING TYPE)
5/8" GYP. BRD. AT FINISH
MOUNTING PLATE AND BOLT
FASTEN LAYERS TOGETHER TO AVOID SHIFTING.
BOLTS MUST FASTEN TO THE LONG SIDE OF 2 x 4
STUD (AS SHOWN).
2 X 4 S. YELLOW PINE NO. 2
2 X 4 S. YELLOW PINE NO. 2
PROPERLY SECURE FRAMING TO
STRUCTURE ABOVE FOLLOWING LOCAL
CODES
TWO GANG BOX WITH 115V POWER FEED
ON DEDICATED 20A CIRCUIT BY
ELECTRICIAN. PROVIDE 18" WHIP.
X-RAY MAX DRAW: 5A
SINGLE-GANG JUNCTION BOX AND
CONDUIT TO ABOVE CEILING (OR PER
CODE) WITH PULL-STRING BY
ELECTRICIAN TO 9A (IF REMOTE) OR 9B.
25' OF CABLE PROVIDED, SEE HENRY
SCHEIN REP.
4 X 4 DOUGLAS FIR-LARCH POSTS BY
CONTRACTOR. SEE STACKED 2 X 4
OPTION DETAIL BELOW IF STRAIGHT,
SOLID 4 X 4 POSTS ARE NOT AVAILABLE.
X-RAY MOUNTING PLATE SUPPLIED AND
INSTALLED BY HENRY SCHEIN DENTAL AT
FINISH. SECURE PLATE USING 3/8"X4"
FULLY-THREADED LAG SCREWS. FINAL
CONNECTIONS BY HENRY SCHEIN
DENTAL.
9B X-RAY EXPOSURE BUTTON
NOT TO SCALE
FOLLOW LOCAL CODES FOR ALL WORK.
DETAIL PROVIDED FOR UTILITY REQUIREMENTS.
REFER TO MANUFACTURER'S INSTALLATION
GUIDE FOR ADDITIONAL INFORMATION.
EXPOSURE BUTTON SUPPLIED AND
INSTALLED BY HENRY SCHEIN
DENTAL AT FINISH.
SINGLE-GANG JUNCTION BOX &
CONDUIT TO ABOVE CEILING (OR
PER CODE) WITH PULL-STRING BY
ELECTRICIAN TO 9A OR 9C
LOCATION. SEE SHEET SE.1.
14A AUTOCLAVE STERILIZER (UNDER COUNTER)
NOT TO SCALE
SINGLE GANG BOX & DUPLEX
OUTLET ON A 115V, 20A
DEDICATED CIRCUIT BY
ELECTRICIAN.
FOLLOW LOCAL CODES FOR ALL WORK.
DETAIL PROVIDED FOR UTILITY REQUIREMENTS.
REFER TO MANUFACTURER'S INSTALLATION
GUIDE FOR ADDITIONAL INFORMATION.
DENTAL STERILIZER SUPPLIED AND
INSTALLED BY HENRY SCHEIN
DENTAL.
VERIFY DIMENSIONS WITH CONTRACTOR AND
CABINET MAKER
15 ULTRASONIC CLEANER (COUNTERTOP)
NOT TO SCALE
SINGLE GANG BOX & 115V
DUPLEX OUTLET BY ELECTRICIAN.
FOLLOW LOCAL CODES FOR ALL WORK.
DETAIL PROVIDED FOR UTILITY REQUIREMENTS.
REFER TO MANUFACTURER'S INSTALLATION
GUIDE FOR ADDITIONAL INFORMATION.
ULTRASONIC CLEANER SUPPLIED
AND INSTALLED BY HENRY
SCHEIN DENTAL.
15B A-DEC ASSISTINA TWIN MAINTENANCE SYSTEM
NOT TO SCALE
FOLLOW LOCAL CODES FOR ALL WORK.
DETAIL PROVIDED FOR UTILITY REQUIREMENTS.
REFER TO MANUFACTURER'S INSTALLATION
GUIDE FOR ADDITIONAL INFORMATION.
ASSISTINA UNIT SUPPLIED AND
INSTALLED BY HENRY SCHEIN
DENTAL.
1/2" AIR SUPPLY LINE FROM
COMPRESSOR BY CONTRACTOR.
STUB-OUT FROM WALL 1”-2”.
TERMINATE WITH 1/4” ANGLE VALVE.
PRESSURE 100 PSI MAX.
SINGLE GANG BOX & 115V
DUPLEX OUTLET BY ELECTRICIAN.
SED.1
24 x 36SEE DETAIL
DENTAL EQUIP.
DETAILS
PO
RT
A N
T N O
TE
TH
IS
D O
C
UM
EN
T
HA
S
BE
EN
P
RE
PA
RE
D A
S A
N
IN
ST
RU
M
EN
T O
F
PR
O
FE
SS
IO
N A
L
SE
RV
IC
E A
N D
IS
N
O T
A N
A
RC
HI
TE
C
TU
RA
L
PL
A
N
TH
E
ID
EA
S/ D
ES
IG
N
IN
C
LU
D
ED
H
ER
EI
N
A
RE
T
HE
S O
LE
P
RO
PE
RT
Y
O F
HE
N
RY
S
C
HE
IN
, I
N C
. A N
D A
RE
P
RO
TE
C
TE
D U
N D
ER
C
O
PY
RI
G
HT
TH
ES
E
PL
A N
S M
A Y
N O
T
BE
U
SE
D O
R
RE
PR
O
D
UC
ED
W
ITH
O
UT
E
XP
RE
SS
ED
W
RI
TT
EN
C O
N
SE
N T
O F
HE
N
RY
S
C
HE
IN
, I
N C
A
N D
F
UL
L
PA
YM
EN
T O
F A
N Y
A
SS
O C
IA
TE
D D
ES
IG
N F
EE
S.
A
LL
D
IM
EN
SI
O N
S A
RE
S
UB
JE
C T
TO
J
O B-
SI
TE
V
ER
IF
IC
A
TIO
N
REVISIONS:
HENRY SCHEIN REP:
PR
O
JE
C
T:
LO
C
A
TIO
N
SCALE:…