ITB 2026-002 Downtown Streetscape Project-Drawings.pdf
PDF 20 MB Posted
- Attached to
- ITB 2026-002 Downtown Streetscape Improvement Project-Main Street: White Oak Alley to Market Street
- Solicitation number
- IFB-119866
- Issued by
- Newport News City, Salem City, Virginia
About this file
This document consists of detailed construction drawings for ITB 2026-002, the Downtown Streetscape Improvements Project on Main Street in Salem, Virginia, prepared under VDOT Project No. U000-129-255, P101, R201, C501 / UPC 119473 and FHWA Project No. STP-5129(010). The drawings, prepared by WM. Thomas Austin (License No. 030907) and the firm Mattern & Craig under the direction of William L. Simpson, Jr., P.E., Assistant Director/City Engineer of the Department of Community Development, illustrate comprehensive streetscape improvements spanning from White Oak Alley to Market Street. The project includes multiple discipline plans covering site demolition and removal, streetscape hardscape with brick paver details, accessible ramps and crosswalks, storm drain installation with sediment and erosion control measures, utility coordination, landscape planting with tree and shrub specifications, irrigation systems, electrical lighting infrastructure with pole-mounted luminaires and ground uplighting, pavement markings, signage, and three-stage maintenance of traffic (MOT) plans with detour routes. The drawings encompass 11 primary plan sheets with detailed sections, schedules, and specifications addressing all construction phases and site coordination requirements.
The electrical component includes a 16.7 KVA electrical service cabinet (ESC-A) with 69.7-amp capacity providing power distribution to nine street light poles with integrated strand lighting, Christmas lighting circuits, uplighting, and pole and ground-mounted receptacles controlled through multiple contactors and time-clock systems. The landscape design specifies multiple overstory trees including River Birch, Hackberry, Ginkgo, Honeylocust, Crapemyrtle, Blackgum, Nuttall Oak, Bald Cypress, and Lacebark Elm, along with shrubs such as Boxwood, Hydrangea, Holly, and Yew, complemented by perennial plantings of Tickseed, Coneflower, Geranium, Daylily, Catmint, and Little Bluestem at specified spacing intervals. Traffic control plans detail sidewalk closures, pedestrian crossings, road work signage, and phased construction sequencing to maintain local traffic access and pedestrian safety throughout the project duration.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CITY OF SALEM
DOWNTOWN STREETSCAPE IMPROVEMENTS PROJECT
MAIN STREET: WHITE OAK ALLEY TO MARKET STREET
VDOT PROJECT NO.: U000-129-255, P101, R201, C501 / UPC 119473
FHWA PROJECT NO.: STP-5129(010)
INVITATION TO BID #2026-002
WM. THOMAS AUSTIN
Lic. No. 030907
CITY OF SALEM
WILLIAM L. SIMPSON, JR. P.E.
Asst. Director/City Engineer / Department of Community Development3/11/2026
M a tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
2.1 tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
3.1
M a tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
4.1 a tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
5.1 tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
5.2
PLAN
A
A
SECTION A-A
PLAN
A
A
SECTION A-A
PLAN
A
A
SECTION A-A
PLAN
A
A
SECTION A-A
M a tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
5.3 tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
5.4 tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
6.1 tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
6.2 tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
6.3
EROSION & SEDIMENT CONTROL
SYMBOLS LEGEND
tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
7.1 tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
7.2 tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
8.1 tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
8.2 tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
8.3 tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
8.4 tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
8.5
PANEL NAME: ESC-A VOLTS: 120/240 MAIN CRT. BRK. - POLE 2, AMPS 150, FRAME FA, LOCATION TOP
MFG: SQUARE-D WIRE: 3 MAIN AMPS: 225
PNL TYPE: NQ PHASE: 1 NEUTRAL AMPS: 225
ENCLOSURE: SURFACE NEMA-3R NEUTRAL AMPS: 225
C
CIRCUIT DESCRIPTION
C
I BRKR. WIRE (1) WIRE (1) BRKR. I
R C C R C O O C
U CIRCUIT DESCRIPTION K F P A K P N E N MAIN N E N P K A P F K U
I V R O M A H E G D BRKR D G E H A M O R V I
T A A L P I A U C U U C U A I P L A A T
M E S C S T I I T S C S E M N E S E T T E S E N O (2) (2) O
1 POLE REC: EMA - 1 1.00 QOB 1 20 10 12 12 12 1 1 10 10 10 10 20 1 QOB 1.00 POLE REC: EMA - 2 2 3 POLE REC: EMA - 3 1.00 QOB 1 20 10 12 12 12 1 1 10 10 10 10 20 1 QOB 1.00 POLE REC: EMA - 4 4 5 POLE REC: EMA - 5 1.00 QOB 1 20 10 12 12 12 1 1 10 10 10 10 20 1 QOB 1.00 POLE REC: EMA - 6 6 7 POLE REC: EMA - 7 1.00 QOB 1 20 10 12 12 12 1 1 10 10 10 10 20 1 QOB 1.00 POLE REC: EMA - 8 8 9 SPARE 0.20 QOB 1 20 10 12 12 12 1 1 10 10 10 10 20 1 QOB 1.00 POLE REC: EMA - 9 10 11 CHRISTMAS LIGHTS: EMA-1 & EMA-2 0.10 QOB 1 20 10 12 12 12 1 1 12 12 12 10 20 1 QOB 0.10 CHRISTMAS LIGHTS: EMA-5 & EMA-6 12 13 CHRISTMAS LIGHTS: EMA-3 & EMA-4 0.10 QOB 1 20 10 12 12 12 1 1 12 12 12 10 20 1 QOB 0.10 CHRISTMAS LIGHTS: EMA-7, EMA-8 & EMA-914 15 GROUND REC: GR-1 1.00 QOB 1 20 10 12 12 12 1 1 12 12 12 10 20 1 QOB 1.00 GROUND REC: GR-2 16 17 GROUND REC: GR-5 1.00 QOB 1 20 10 12 12 12 1 1 12 12 12 10 20 1 QOB 1.00 GROUND REC: GR-4 18 19 GROUND REC: GR-6 1.00 QOB 1 20 10 12 12 12 1 1 10 10 10 10 20 1 QOB 0.10 UPLIGHTS: UL-1, 2 20 21 UPLIGHTS: UL-4 0.10 QOB 1 20 10 10 10 10 1 1 10 10 10 10 20 1 QOB 0.10 UPLIGHTS: UL-5, 6 22 23 STRAND LIGHTING: EMA - EX. / 5 / 1 0.30 QOB 1 20 10 12 12 12 1 1 12 12 12 10 20 1 QOB 0.30 STRAND LIGHTING: EMA 2-7-3 24 25 STRAND LIGHTING: EMA - 1 / 6 / 2 0.30 QOB 1 20 10 12 12 12 1 1 12 12 12 10 20 1 QOB 0.30 STRAND LIGHTING: EMA 3-8-4-9 26 27 DMX CONTROLLER (GROUND LIGHTS) 0.30 QOB 1 20 10 12 12 12 1 1 10 10 10 10 20 1 QOB 0.01 CONTACTOR: UPLIGHT & STRAND LIGHTING28 29 LANDSCAPE IRRIGATION CONTROLLER 0.20 QOB # 20 10 10 10 10 1 1 10 10 10 10 20 1 QOB 0.01 CONTACTOR: GROUND & POLE REC 30
31 1 10 10 10 10 20 1 QOB 0.01 CONTACTOR: CHRISTMAS LIGHTS 32
33 3/4 10 10 10 10 20 1 QOB 0.10 CONVENIENCE RECEPTACLE, FAN 34
35 36 37 38 39 40 41 42
TOTAL ADD = TOTAL8.6 8.1 16.7 KVA
(69.7 AMPS)
PANEL LOCATION: ELECTRICAL SERVICE
CABINET (ESC) "A" NOTES:
(1) REMARKS: ADJUST WIRE SIZES PER NEC FOR LONG RUNS OF CONDUCTORS
(2) CONDUIT SIZE SHOWN IS MINIMUM
ACTUAL BREAKER INTERRUPTING CURRENT =
KAIC * 1000
S/O = SPACE ONLY
M a tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
8.6
NOTES:
PROVIDE SCREW/BOLT ON ISOLATION PLATE AND SHORT STANDOFFS TV
COVER BACK OF CABINET. ISOLATION PLATE (FIBERGLASS OR PHENOLIC
TO BE USED TO MOUNT ELECTRICAL COMPONENTS. COMPONENTS ARE
PANEL BOARD, CONTACTOR, TIME CLOCKS, DMX CONTROLLERS, FANS,
AND ETC. AS SHOWN ON 1/7.9 AND 2/7.9.
ELECTRIC SERVICE CENTER (ESC) - A
Pole: EMA - 1 Pole: EMA - 2 Pole: EMA - 3
Designation / Load: Device Designation: Designation / Load: Device
Designation: Designation / Load: Device Designation:
Strand Lighting: - Strand Lighting: - Strand Lighting: - Christmas Lighting: CL - 1 Christmas Lighting: CL - 2 Christmas Lighting: CL - 3 Pole Receptacle: PR - 1 Pole Receptacle: PR - 2 Pole Receptacle: PR - 3 Ground Lighting: - Ground Lighting: UL-1 Ground Lighting: UL-2 Ground Receptacle: - Ground Receptacle: GR-1 Ground Receptacle: GR-2
Pole: EMA - 4 Pole: EMA - 5 Pole: EMA - 6
Designation / Load: Device Designation: Designation / Load: Device
Designation: Designation / Load: Device Designation:
Strand Lighting: - Strand Lighting: SL - EX./5/1 Strand Lighting: SL - 1/6/2 Christmas Lighting: CL - 4 Christmas Lighting: CL - 5 Christmas Lighting: CL - 6 Pole Receptacle: PR - 4 Pole Receptacle: PR - 5 Pole Receptacle: PR - 6 Ground Lighting: - Ground Lighting: - Ground Lighting: - Ground Receptacle: - Ground Receptacle: - Ground Receptacle: -
Pole: EMA - 7 Pole: EMA - 8 Pole: EMA - 9
Designation / Load: Device Designation: Designation / Load: Device
Designation: Designation / Load: Device Designation:
Strand Lighting: SL - 2/7/3 Strand Lighting: SL - 3/8/4/9 Strand Lighting: - Christmas Lighting: CL - 7 Christmas Lighting: CL - 8 Christmas Lighting: CL - 9 Pole Receptacle: PR - 7 Pole Receptacle: PR - 8 Pole Receptacle: PR - 9 Ground Lighting: UL-4 Ground Lighting: - Ground Lighting: UL-6 Ground Receptacle: GR-4 Ground Receptacle: - Ground Receptacle: GR-6
LEGEND:
CL-# = CHRISTMAS LIGHT PR-# = POLE RECEPTACLE UL-# = GROUND UPLIGHTING
SL-# = STRAND LIGHT GR-# = GROUND RECEPTACLE
NOTES:
1. DEVICE DESIGNATION ID: REFER TO PLAN SHEETS FOR DEVICE DESIGNATION LOCATIONS AND REFER TO PANEL SCHEDULE FOR CIRCUIT NO. ASSIGNMENT
2. SCHEDULE INDICATES LOAD TYPE AND DEVICE PRESENT AT EACH STREET LIGHT POLE ARRANGEMENT.
UL-1
120V N
120V
CONTROL BREAKER IN PANELBOARD ESC-A
CONTACT TO LIGHT CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
120V
CONTACTOR IN ENCLOSURE
CONTACTOR SEQUENCE FOR
SCHEMATIC
GROUND UPLIGHTS (UL) AND STRAND LIGHTS (SL)
ESC-A-28
SL-1-6-2
NOTES:
CONNECT SERVING BREAKER TO COIL TO CONTROL CONTACTOR (LOCATED IN PANELBOARD (ESC-A) CONTACTOR SHALL OPERATE GROUND UPLIGHT AND STRAND LIGHT CIRCUITS AS INDICATED ON PLANS AND TABLES. THE CONTROL WIRING BETWEEN THE SERVERING BREAKER AND
CONTACTOR COIL SHALL BE CONNECTED TO CIRCUIT AS INDICATED.
CONTACTOR SHALL BE IN A NEMA-3R ENCLOSURE.
UL-# = GROUND MOUNTED UP-LIGHTS
SL # = STRAND LIGHTS
120V
120V
120V
120V
120V
120V
120V
UL-2
UL-4
UL-6
UL-5
CONTACT TO LIGHT CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
CONTACT TO LIGHT CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
CONTACT TO LIGHT CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
TC PC
120V N
120V
CONTROL BREAKER IN PANELBOARD ESC-A
CONTACT TO RECEPTACLE CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
120V
CONTACTOR IN ENCLOSURE
CONTACTOR SEQUENCE FOR GROUND (GR)
SCHEMATIC
AND POLE MOUNTED RECEPTACLES (PR)
ESC-A-30
NOTES:
CONNECT SERVING BREAKER TO COIL TO CONTROL CONTACTOR (LOCATED IN PANELBOARD (ESC-A) CONTACTOR SHALL OPERATE GROUND AND POLE MOUNTED RECEPTACLE CIRCUITS AS INDICATED ON PLANS AND TABLES. THE CONTROL WIRING BETWEEN THE SERVERING BREAKER AND CONTACTOR COIL SHALL BE CONNECTED TO CIRCUIT AS INDICATED.
CONTACTOR SHALL BE IN A NEMA-3R ENCLOSURE.
GR-# = GROUND MOUNTED RECEPTACLE
PR-# = POLE MOUNTED RECEPTACLE CORRESPONDING TO POLE NUMBER
120V
120V
120V
120V
120V
120V
120V
CONTACT TO RECEPTACLE CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
CONTACT TO RECEPTACLE CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
CONTACT TO RECEPTACLE CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
CL-1,2
120V
120V
C
CONTACTOR IN ENCLOSURE
CONTACTOR SEQUENCE FOR
SCHEMATIC
CHRISTMAS LIGHTS (CL)
SPARE
120V
120V
120V
120V
120V
CL-3,4
CL-5,6
CL-7,8,9
SPARE
TO EXISTING CHRISTMAS LIGHT CONTROLLER
120VESC-A-32
NOTES:
CONNECT EXISTING CHRISTMAS LIGHT CONTROL WIRING (240 VOLT) TO COIL. PROVIDE LARGE ENOUGH WIRE TO HANDLE VOLTAGE DROP. ALSO LIGHTING CONTACTOR WITH (2) WIRE CONTROL AT 240 VOLT WITH 120 VOLT POLES FOR
LIGHTING.
CONNECT EXTENDED CHRISTMAS LIGHTING CONTROLLER CIRCUIT TO COIL TO CONTROL CONTACTOR (LOCATED IN PANELBOARD NCS) CONTACTOR SHALL OPERATE CHRISTMAS LIGHT CIRCUITS AS INDICATED ON PLANS AND TABLES.
THE CONTROL WIRING BETWEEN THE SERVERING BREAKER AND CONTACTOR COIL SHALL BE CONNECTED TO CIRCUIT
AS INDICATED.
CONTACTOR SHALL BE IN A NEMA-3R ENCLOSURE.
240V
120V
120V
CONTACT TO RECEPTACLE CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
CONTACT TO RECEPTACLE CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
CONTACT TO RECEPTACLE CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
CONTACT TO RECEPTACLE CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
CONTACT TO RECEPTACLE CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
CONTACT TO RECEPTACLE CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
120V
120V
CONTACT TO LIGHT CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
CONTACT TO LIGHT CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
EMA-1 AND 2
EMA-3 AND 4
EMA-5 AND 6
EMA-7
SL-2-7-3
SL-3-8-4-9 CONTACT TO STRAND LIGHT CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
ESC-A
ESC-A
ESC-A
SL-EX-5-1
SPARE
PR-1,2
GR-1,2
GR-3,4
PR-3,4
PR-5,6
PR-7,8
SPARE
PR-9
SPARE
GR-5,6
CONTACT RATED FOR A MINIMUM OF 20 AMPS.
CONTACT RATED FOR A MINIMUM OF 20 AMPS.
PNL-ESC-A
CON CON
TC
DMX
PC
NOTES:
REMOTE CONTROL LIGHTING CONTACTOR, ASCO 918 CONTACTOR, 12 POLE, 20A, 120V, NEMA-3R
ENCLOSURE. #10 WIRE REQUIRED FOR CONTROL.
DIGITAL TIME CLOCK, NSI TORK DIGITAL 365/7 DAY TIME SWITCH, TWO(2) CHANNEL,
#DG100A-Y-82221,120/277, 2 CH, DPDT.
PHOTOCONTROL, NSI TORK #2001 PHOTOCELL, 120V, 2000W, ADJUSTABLE 1/2" CONDUIT STEM
MOUNTED.
HOFFMAN NEMA 3R, HINGED TWO (2) DOOR ENCLOSURE, LOCKABLE HANDLE, PADLOCK PROVISION IN HANDLE, A60R5218FSLP, 60" X 52" X 18", WITH FIBERGLASS OR PHENOLIC BACK MOUNTING PLATE.
SPACE FOR DMX CONTROLLER (GROUND LIGHTS) AND TRAILING EDGE CONTROLLER (STRAND LIGHTS).
120V FAN, FOR PUSHING AIR OUT THROUGH TOP VENTS, CONNECT TO CIRCUIT SCS-9.
REMOTE CONTROL LIGHTING CONTACTOR, ASCO 918 CONTACTOR, 12 POLE, 20A, 120V, NEMA-3R ENCLOSURE. #10 WIRE REQUIRED FOR CONTROL, 240V CONTROL COIL 2 WIRE CONTROL. CONTROL POWER COMES FROM EXISTING CHRISTMAS LIGHT CONTROLLER ON WEST SIDE OF EAST MAIN STRET.
PROVIDE #6 WIRE FOR CONTROL CIRCUIT TO BOTH CONTACTORS.
1 1
FAN
CON
SCHEMATIC
NEMA-3R ENCLOSURE
FOR ELECTRICAL SERVICE
GROUND
AND POLE
RECEPTACLES
CHRISTMAS
LIGHTS
GROUND
LIGHTS
GROUND
LIGHTS
SCS-34
CONTACT TO STRAND LIGHT CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
CONTACT TO STRAND LIGHT CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
CONTACT TO STRAND LIGHT CIRCUIT (RATED FOR A MINIMUM OF 20 AMPS.)
tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
9.1
PLANT SCHEDULE (THIS SHEET ONLY)
QTY ID BOTANICAL NAME COMMON NAME SIZE ROOT SPACING NOTES
OVERSTORY TREES
BN Betula nigra DuraHeat Dura Heat River Birch 10-12' HT. B&B AS SHOWN (3) MULTI-STEM
CM Celtis x 'Magnifica' Magnifica Hackberry 3" CAL. B&B AS SHOWN GB Ginkgo biloba 'Autumn Gold' Autumn Gold Ginkgo 3" CAL. B&B AS SHOWN GT Gleditsia triacanthos f. inermis 'Skyline' Skyline Honeylocust 3" CAL. B&B AS SHOWN LD Lagerstroemia Dynamite Dynamite Crapemyrtle 6-8' HT. B&B AS SHOWN (3-5) MULTI-STEM
NS Nyssa sylvatica 'Red Rage' Red Rage Blackgum 3" CAL. B&B AS SHOWN QT Quercus nuttallii Nuttall Oak 3" CAL. B&B AS SHOWN TD Taxodium distichum 'Mickelson' Mickelson Bald Cypress 3" CAL. B&B AS SHOWN UP Ulmus parvifolia 'Allee' Allee Lacebark Elm 3" CAL. B&B AS SHOWN
SHRUBS
BM Buxus macrophylla 'Little Missy' Little Missy Boxwood 12"-15" Ht. #3 Cont. AS SHOWN HQ Hydrangea quercifolia 'Ruby Slippers' Ruby Slippers Hydrangea 24"-30" Ht. B&B/#7 Cont. AS SHOWN FG Fothergilla gardenii 'Mount Airy' Mount Airy Fothergilla 30"-36" Ht. B&B AS SHOWN IG Ilex glabra ' Shamrock' Shamrock Inkberry Holly 24"-30" Ht. #7 Cont. AS SHOWN RA Rhus aromatica 'Low Grow' Low Grow Sumac 24"-30" Ht. #7 Cont. AS SHOWN TB Taxus baccata 'Repandens' Repandens Yew 24"-30" Ht. B&B AS SHOWN
PERENNIALS
CG Coreopsis grandiflora 'Double the Sun' Double the Sun Tickseed #1 Cont. 18" O.C.
EC Echinacea 'Cheyenne Spirit Cheyenne Spirit Coneflower #1 Cont. 24" O.C.
GR Geranium 'Rozanne' Rozanne Geranium #1 Cont. 15" O.C.
HG Hermerocallis 'Gentle Shepherd' Gentle Shepherd Daylily #1 Cont. 24" O.C.
HM Hermerocallis 'Pardon Me' Pardon Me Daylily #1 Cont. 24" O.C.
HP Hermerocallis 'Purple d'Oro' Purple d'Oro Daylily #1 Cont. 24" O.C.
NM Narcissus 'Manly' Manly Daffodil Bulb 8" O.C.
NF Nepeta x faassenii 'Junior Walker' Junior Walker Catmint #1 Cont. 24" O.C.
SS Schizachyrium scoparium 'Smoke Signal' Smoke Signal Little Bluestem #1 Cont. AS SHOWN VW Veronica 'First Love' First Love Speedwell #1 Cont. 18" O.C.
tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
9.2
8.28.2
3 TREE BED IN STONE SOIL - SECTION
3/8" = 1'-0"
8.28.2
2 SHRUB AND PERENNIAL/GROUNDCOVER PLANTING
NTS
8.28.2
4 TYPICAL PLANT SPACING
NTS
8.28.2
1 TREE BED IN STONE SOIL - PLAN
1/4" = 1'-0"
* IF SYNTHETIC
MAT'L IS USED,
REMOVE ENTIRELY
FROM BALL
CUT BURLAP*, ROPE AND WIRE BASKET
AWAY FROM TOP 2/3 AND SIDES OF ROOT
BALL. DO NOT DISTURB OR BREAK BALL
SUPPORT TREE W/ ARBOR TIE ROPE AND
ARBOR TIE KNOT, INSTALL PER MANF.
RECOMMENDATIONS AND PROJECT SPECS
EXCAVATE TREE PIT AND PLACE STONE
SOIL MIXTURE PER SPECS,
DO NOT PLACE SOIL ON TOP OF
ROOTBALL
SCARIFY SUBSOIL &
LIGHTLY COMPACT
3'- 0"
BRICK BORDER, DRY LAID TREE PIT, SEE PLAN
FOR WIDTH
STONE SOIL MIX SEE
PLANS FOR AREA
2" BAMBOO STAKES, 2 PER TREE
4" PLANTING SOIL
3" MULCH
BRICK PAVING, SEE CIVIL
ROOT BARRIER
18" DEEP
ROOT BARRIER
18" DEEP
GROUNDCOVER
MATERIAL
MULCH SAUCER
AROUND
SHRUB LOOSEN BURLAP AND FOLD BACK FROM TOP
THIRD OF ROOT BALL
3" MULCH (NO MULCH WITHIN 3" OF TRUNK)
1 1/2" MULCH (NO MULCH
WITHIN 2" OF BASE
MAINTAIN CLEAN BED EDGE
SCARIFY SIDES OF PIT
PLANTING SOIL MIX 'B' TOP
OF SOIL SHOUD BE JUST
BELOW ROOT COLLAR
4" MIN.
6" MIN.
EQ. EQ. EQ.
6" MIN.
4" TOPSOIL
PLANTING SOIL
.86 Z
TY
P.
Z Z
Z
Z = SPACING
AS INDICATED
IN PLANT
SCHEDULE
BACK OF SIDEWALK
SEE LAYOUT PLANS
FOR BRICK PATTERNS
CONC CURB AND GUTTER
TREE / PLANT BED
TREE CENTERED IN BED,
UNLESS OTHERWISE
SHOWN ON PLAN
SEE PLANTING PLANS
VARIES, SEE PLAN
VA
RI
ES
SE
E
PL
AN
AREA OF STONE SOIL BELOW PAVING
18" ROOT BARRIER EDGE
RESTRAINT AROUND
PERIMETER OF BED
6"
FACE OF CURB
8.1
3 8.1
LIMIT OF STONE SOIL
BACKFILL
tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
9.3 tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
10.1
SIGN LEGEND / SCHEDULE
KEY
SYMBOL SIGN MUTCD
STANDARD DIMENSIONS
BACKGROUND
FOREGROUND / LETTER
COLORS
1 "PEDESTRIAN CROSSING" WITH LEFT
DOWNWARD DIAGONAL ARROW
SIGN - W11-2
ARROW - W16-7P(L)
30" X 30" 24" X 12"
2 "PEDESTRIAN CROSSING"
"AHEAD"
W11-2 W16-9P
30" X 30"
24" X 12" FLUORESCENT YELLOW - GREEN
3 "NO PARKING HERE TO CORNER" R7-11 12"x18" WHITE
RED BORDER / RED LETTERS
4 "2-HOUR PARKING" / "7AM - 6PM"R7-108 12"x18" WHITE
GREEN BORDER / GREEN LETTERS
5 "DO NOT BLOCK DRIVEWAY" N/A 12"x18" WHITE
BLACK BORDER / BLACK LETTERS
NOTE:
1. ALL SIGNS SHALL BE PROVIDED AND INSTALLED BY CITY OF SALEM - STREET DEPARTMENT.
2. CONTRACTOR SHALL INSTALL SIGN BASE AND SLEEVE AS SHOWN ON PLAN SHEET 5.3.
FLUORESCENT YELLOW - GREEN
tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
11.1 tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
11.2
ROAD
CLOSED
AHEAD
DETOUR
END
DETOUR
MAIN ST.
MAIN ST.
MAIN ST.
CLOSED
ROAD
MAIN ST.
DETOUR
CLOSED
LOCAL TRAFFIC ONLY
0.1 MILES AHEAD
ROAD CLOSED
TO
THRU TRAFFIC
DETOUR
AHEAD
DETOUR
CLOSED
ROAD
ROAD
WORK
AHEAD
W20-1 48" x 48"
G20-2(V) 24" x 48"
G
-2 (V
R O
A D
W O
R K
A H
E A
D
W 20-1
R
IG
H T
S H
O U
LD
E
R C
LO
S
E D
A H
E A
D
W 21-5bR
R
IG
H T
S H
O U
LD
E
R C
LO
S
E D
W 21-5aR
" x
8"
48" x 48"
48" x 48"
48" x 48"
SIDEW
ALK CLO
SED
CRO
SS HERE
R 9-11aL
48" x 24" S
E E
N O
TE
ROAD
WORK
AHEAD
W20-1 48" x 48"
G20-2(V) 24" x 48"
P
R O
A D
W O
R K
A H
E A
D
W
-1
"x
R9-11aR 48" x 24"
SIDEWALK CLOSED
CROSS HERE
R8-3 36" x 36" SEE NOTE 1
PEDESTRIAN
CHANNELIZING
DEVICE
PEDESTRIAN
CHANNELIZING
DEVICE
SIDEWALK
CLOSED
R9-9 48" x 24"
R9-9 48" x 24"
SIDEWALK
CLOSED
M a tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
11.3
G 20-2(V
24" x 48"
G 20-2(V
R O
A D
W O
R K
A H
E A
D
W
-1
R
IG
H T
S H
O U
LD
E
R C
LO
S
E D
A H
E A
D
W
-5 bR
R
IG
H T
S H
O U
LD
E
R C
LO
S
E D
W
-5 aR
24" x 48"
" x
8"
" x
8"
" x
8"
G
-2 (V
" x
8" SIDEW
ALK CLO
SED
CRO
SS HERE
R 9-aR
" x
4"
S E
E N
O
TE
48" x 48"
R O
A D
W O
R K
A H
E A
D
W 20-1
SIDEWALK
CLOSED
R9-9 48" x 24"
SIDEWALK CLOSED
CROSS HERE
R9-11aL 48" x 24"
P
R8-3 36" x 36"
PEDESTRIAN
CHANNELIZING
DEVICE
SEE NOTE 1
PEDESTRIAN
CHANNELIZING
DEVICE
SIDEWALK
CLOSED
R9-9 48" x 24"
ROAD
WORK
AHEAD
W20-1 48" x 48"
G20-2(V) 24" x 48"
ROAD
WORK
AHEAD
W20-1 48" x 48"
G20-2(V) 24" x 48"
M a tt e rn
C ra ig
WM
. T
HO
MA
S A
US
TIN
Li c.
No
. 0
11.4
| 1.1 COVER SHEET |
| 2.1 GENERAL NOTES LEGENDS |
| 3678F_Details-2.1 GENERAL NOTES LEGENDS |
| 3.1 EXISTING CONDITIONS SURVEY PLAN |
| d3678F-3.1 EXISTING CONDITIONS SURVEY PLAN |
| 4.1 DEMOLITION REMOVAL PLAN |
| d3678F-4.1 DEMOLITION REMOVAL PLAN |
| 5.1 STREETSCAPE PLAN |
| d3678F-5.1 STREETSCAPE PLAN |
| 5.2 DETAILS AND SECTIONS - PAVER |
| 3678F_Details-5.2 DETAILS AND SECTIONS - PAVER |
| 5.3 DETAILS AND SECTIONS |
| 3678F_Details-5.3 DETAILS AND SECTIONS |
| 5.4 ENLARGED PLAN- ACCESSIBLE RAMP AND CROSSWALK |
| 3678F_Details-5.4 ENLARGED PLAN- ACCESSIBLE RAMP AND CROSSWALK |
| 6.1 STORM DRAIN PLAN AND PROFILE |
| d3678F-6.1 STORM DRAIN PLAN AND PROFILE |
| 6.2 STORM DRAIN PLAN AND PROFILE |
| d3678F-6.2 STORM DRAIN PLAN AND PROFILE |
| 6.3 - EROSION AND SEDIMENT CONTROL PLAN |
| d3678F-6.3 - EROSION AND SEDIMENT CONTROL PLAN |
| 7.1 UTILITY PLAN |
| d3678F-7.1 UTILITY PLAN |
| 7.2 UTILITY DETAILS AND SECTIONS |
| 3678F_Details-7.2 UTILITY DETAILS AND SECTIONS |
| 8.1 LIGHTING ELECTRICAL PLAN |
| d3678F-8.1 LIGHTING ELECTRICAL PLAN |
| 8.2 LIGHTING ELECTRICAL DETAILS AND SECTIONS - POLE AND LUMINAIRE |
| 3678F_Details-8.2 DETAILS AND SECTIONS - POLE AND LUMINAIRE |
| 8.3 LIGHTING ELECTRICAL DETAILS AND SECTIONS |
| 3678F_Details-8.3 DETAILS AND SECTIONS |
| 8.4 LIGHTING ELECTRICAL DETAILS AND SECTIONS |
| 3678F_Details-8.4 DETAILS AND SECTIONS |
| 8.5 LIGHTING ELECTRICAL DETAILS AND SECTIONS |
| 3678F_Details-8.5 DETAILS AND SECTIONS |
| 8.6 LIGHTING ELECTRICAL CIRCUIT SCHEDULES |
| 3678F_Details-8.6 CIRCUIT SCHEDULES |
| 9.1 STREETSCAPE PLANTING PLAN |
| d3678F-9.1 STREETSCAPE PLANTING PLAN |
| 9.2 PLANTING DETAILS |
| 3678F_Details-9.2 PLANTING DETAILS |
| 9.3 IRRIGATION PLAN |
| d3678F-9.3 IRRIGATION PLAN |
| 10.1 PAVEMENT MARKING SIGNAGE PLAN |
| d3678F-10.1 PAVEMENT MARKING SIGNAGE PLAN |
| 11.1 MAINTENANCE OF TRAFFIC PLAN (MOT) PLAN NOTES AND TYPICAL SECTIONS |
| MOT_3678F-11.1 MAINTENANCE OF TRAFFIC PLAN (MOT) PLAN NOTES AND TYPICAL SECTIONS |
| 11.2 MAINTENANCE OF TRAFFIC (MOT) STAGE 1 DETOUR |
| MOT_3678F-11.2 MAINTENANCE OF TRAFFIC (MOT) STAGE 1 DETOUR |
| 11.3 MAINTENANCE OF TRAFFIC PLAN - STAGE 2 |
| MOT_3678F-11.3 MAINTENANCE OF TRAFFIC PLAN - STAGE 2 |
| 11.4 MAINTENANCE OF TRAFFIC PLAN - STAGE 3 |
| MOT_3678F-11.4 MAINTENANCE OF TRAFFIC PLAN - STAGE 3 |
File details come from the government source that posted it. Updated .