ITB # 1059 Truck Upfitting Admin Doc Amend 1.docx

DOCX document 398 KB Posted

Attached to
One Ton Truck Up Fitting
Solicitation number
1059
Issued by
Ada County, Idaho

About this file

This Invitation to Bid (ITB #1059), issued by the State of Idaho Division of Purchasing on behalf of the Idaho Transportation Department, requests qualified firms to provide one-ton truck upfitting services for multiple Ford F350 vehicles across six districts. The solicitation covers nineteen total vehicles requiring various upfitting configurations, including stainless steel dump bodies, service bodies, cranes, liftgates, storage boxes, message boards, and comprehensive electrical and hydraulic systems. A non-mandatory pre-bid conference is scheduled for October 30, 2025, with questions due by the closing date specified in the IPRO eProcurement system. Bids must be submitted electronically through IPRO by the deadline listed on the event page, with public opening the following business day at 10:30 a.m. Mountain Time. All upfitted vehicles must be delivered to ITD Headquarters at 3311 West State Street, Boise, Idaho within one hundred eighty days after receipt of order, with deliveries accepted Monday through Thursday between 8:00 a.m. and 4:00 p.m. Mountain Time. The contract term is not specified as renewable.

Pricing shall be submitted on Submittal Form B, with award made to the lowest responsive and responsible total cost bidder. Bidders must have been in business providing truck upfittings for a minimum of seven years to meet mandatory responsibility requirements. The solicitation includes detailed specifications for hydraulic systems, electrical components, wiring, fasteners, welding, and specialized equipment such as WHELEN warning lights, Tommygate liftgates, LIFTMOORE cranes, and LINE-X protective coatings. Warranty requirements mandate minimum one-year coverage for all upfitting components and accessories, except lights which require five-year coverage, and service bodies require six-year warranties. All warranty work must be completed within fourteen calendar days of notice. Transportation responsibilities depend on contractor facility location relative to the delivery point: contractors within twenty-five miles of ITD Headquarters are responsible for pickup and delivery costs, while ITD handles transportation for closer facilities. A provision allows contractors to add up to fifty percent of actual tariff costs to invoices if federal tariffs increase material costs, subject to ITD's prior written approval and appropriation availability. No set-asides are identified in this solicitation.

View the file

Other files

File Type Posted
Exhibit 9.jpg JPG image
ITB # 1059 Exhibit 5 Contract Modifications.docx DOCX document
ITB # 1059 Submittal Form A.docx DOCX document
ITB 1059 State of Idaho Contract Terms and Conditions.docx DOCX document
ITB # 1059 Exhibit 4 Questions.docx DOCX document
ITB 1059 Insurance Requirements.docx DOCX document
Amendment 1 ITB # 1059 Draft.docx DOCX document
Exhibit 8 Product Information.docx DOCX document
ITB # 1059 Submittal Form B Pricing Schedule Amend 2.xlsx XLSX spreadsheet
ITB1059 - Exhibit 7 Acceptance Form.docx DOCX document
Exhibit 3 Pre-Bid Registration Fom.docx DOCX document
Amendment 2 ITB # 1059 Draft.docx DOCX document
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATE OF IDAHO

DIVISION OF PURCHASING

FOR

Idaho Transportation Department

Invitation To Bid

One Ton Truck Up Fitting Amended 11/24/2025

ITB Number: 1059

Table of Contents

ITB Section 1 - Administrative Information & Overview
Page 3
ITB Section 2 - Format & Submission Requirements
Page 5
ITB Section 3 - Evaluation & Award Procedures
Page 7
Exhibit 1 - Scope of Work (SOW)
Page 9
Exhibit 1 – List of Acronyms
Page 19
Exhibit 3 - Pre-Bid Conference Registration Form
Attached in IPRO
Exhibit 4 - Questions
Attached in IPRO
Exhibit 5 - Contract Modifications and Exceptions
Attached in IPRO
Exhibit 6 - The Contract
Page 20
Exhibit 7 – Delivery Acceptance From
Attached in IPRO
Exhibit 8 – Product Information
Attached in IPRO
Submittal Form A - Background, Declarations, and Certifications
Attached in IPRO
Submittal Form B – Pricing/Fee Schedule
Attached in IPRO

Section 1 Administrative Information and Overview

1.1 Purpose

The State of Idaho’s (“State”) Division of Purchasing (“DOP”), on behalf of the Idaho Transportation Department is issuing this Invitation To Bid (“ITB”) to solicit Bids from qualified and experienced firms (“Bidders”), that can One Ton Truck Up Fitting as described in this Invitation to Bid. The complete Specifications are provided in Exhibit 1.

1.2 Procurement Schedule

Deadline to submit questions:

Closing Date (deadline to submit Bid):

Public Opening Date:

The State will make every effort to adhere to the schedule below, but reserves the right, at its sole discretion, to adjust the schedule.

See IPRO Event Page See IPRO Event Page The following business day after closing @ 10:30 am MT

1.3 ITB Lead

Name Title & Agency Email The individual listed below (referred to as “ITB Lead”) is responsible for the conduct of this procurement. From the issue date of this ITB, until a contract is awarded, or the ITB is cancelled, Bidders are prohibited from communicating with any State employee, Official, or Evaluators regarding this ITB or procurement.

Michael Piccono Purchasing Officer, Division of Purchasing Michael.Piccono@adm.idaho.gov

1.4 Pre-Bid Conference

Link:

A non-mandatory pre-bid conference will be held to provide an overview of the ITB process, the scope of work, and submission requirements. While attendance is highly encouraged, it is not mandatory. The meeting will be conducted virtually, with the access link provided below. To inform the State of your planned interest and attendance, please complete and submit Exhibit 3 to the ITB Lead no later than 5:00 PM, Mountain Time, 2025 Thursday October 30, 2025.

A Microsoft Teams link will be provided to all interest participants who submit Exhibit 3 to the ITB Lead.

1.5 IPRO eProcurement System

This Solicitation is issued by the State via the State’s eProcurement system, IPRO. It is the Bidder’s responsibility to monitor IPRO for any updates or amendments.

1.6 Questions

The Bidder SHALL review this entire ITB solicitation, including associated documents. All questions, requests for clarification, or other correspondence must be submitted in writing via email to the ITB Lead. See Exhibit 4 for additional instructions. Questions must be submitted using the table provided within Exhibit 4.

1.7 Modifications and Exceptions to Requirements, Terms, and Conditions The Bidder SHALL review the Contract requirements, terms, and conditions. The Bidder is strongly encouraged to submit any proposed modifications, or exceptions to the Contract requirements, terms, or conditions to the ITB Lead prior to the deadline for submitting questions. See Exhibit 5 for additional instructions. Modifications and exceptions must be submitted using the table provided within Exhibit 5. The Contract requirements, terms, and conditions are provided in Exhibit 6.

Any modifications or exceptions that are raised after the Bid has been submitted, may be rejected by the State without further discussion. Therefore, the Bidder is strongly encouraged to submit any proposed modifications or exceptions during the Q&A period. Bids which condition the Bid based upon the State accepting other terms and conditions not found in the ITB, will be found non-responsive, and no further consideration of the Bid will be given.

1.8 Amendments

The State may issue amendments to make changes to the ITB, or to respond to any questions. Amendments will be posted on IPRO. Bidders are responsible for monitoring IPRO for updates and amendments. All published amendments SHALL become part of this ITB, and must be considered by the Bidder in its Bid. Oral interpretations or clarifications of this ITB are not binding and should not be relied upon. Any verbal responses provided by the State during the pre-Bid conference are considered unofficial, and will not be binding.

1.9 Authority

This procurement is conducted in accordance with IDAPA 38.05.01 and pursuant to Title 67, Chapter 92 of the Idaho Code.

Section 2 Format & Submission Requirements

2.1 Adherence to Requirements

The Bid SHALL be submitted in accordance with the requirements set forth in this document. Any Bid that does not adhere to the requirements may be deemed non-responsive and rejected. The State reserves the right, in its sole discretion, to overlook any minor informalities that may be non-compliant.

2.2 Deadline to Submit

All Bids are due at the date and time specified in the Procurement Schedule (Section 1.2). Late Bids SHALL NOT be accepted or considered. The State SHALL not be responsible for any technical issues, difficulties, or delays. Bidders are strongly encouraged to begin the process of submitting the Bid response far enough in advance of the Closing Date/Time to allow for resolution of any technical difficulties.

2.3 General Format Requirements

The Bid response must meet the following requirements:

· Be made on standard 8.5” x 11” paper size.

· Use a minimum font size of ten (10) (images, figures, graphs, charts, are excluded from this font size).

· Use a font style such as: Calibri, Arial, New Times Roman, or similar.

· The Bidder SHALL NOT embed information, embed files, or embed any links within the Submittals.

· The Bidder SHALL NOT attach additional information to any Submittal Form (unless it has been explicitly requested). Any additional attachments submitted will not be considered in the evaluation process.

2.4 Electronic Submission Instructions

The Bidder SHALL submit the Bid as follows:

· The Bid SHALL be submitted electronically through IPRO POWERED BY LUMA. The State will not accept Bids in any other manner (i.e. facsimile, email, or hardcopy submissions). All Bidders participating in this Solicitation must establish an account in the IPRO system, as it is necessary in order to process and/or award the resulting Contract(s). Establishing an account is free.

Link: Luma IPRO Supplier Portal Registration link

Please make sure that the entity profile under which the Bid is submitted in IPRO, is the same legal entity presented in the uploaded response materials. If there are any discrepancies, the entity information provided within Submittal Form A prevails.

· The Bid must be submitted in the following packages:

No
Contents
File Format
How To Name The Files
1
Submittal Form A
MS Word
1 <Insert Bidder Name>
2
Submittal Form B
MS Word / MS Excel
2 <Insert Bidder Name>
3*
Redacted Submittal Forms*
PDF
3 <Insert Bidder Name> REDACTED
4
Exhibit 8 Product Information
MS Word
4 <Insert Bidder Name>
5
Warranty Information
MS Work/PDF
5<Insert Bidder Name>

* If applicable. Applies to Bids with trade secrets as discussed below.

· All electronic files must be in Adobe PDF, Microsoft Word, or Microsoft Excel format as noted in the table above.

· The Bid file(s) SHALL NOT be password protected or locked in any way.

· All submission materials must be submitted at the same time. If multiple submissions are received, only the latest timely submission will be considered.

· Alternate Bids are not allowed.

· Note: When submitting through IPRO, enter your Cost in IPRO as “$0.01,”

· Package 3: If your Bid contains trade secrets (see next Section), submit an additional redacted version. This should be labeled as Package 3 and include 'Redacted' in the file name.

2.5 Trade Secrets and Non-Public Information

The Idaho Public Records Act, Idaho Code title 74, chapter 1 (the “Act”) defines trade secrets to “include a formula, pattern, compilation, program, computer program, device, method, technique or process that derives economic value, actual or potential, from not being generally known to, and not being readily ascertainable by proper means by other persons and is subject to the efforts that are reasonable under the circumstances to maintain its secrecy.” The Act also defines other records that may be exempt from public disclosure.

In addition to marking each page of the document with a trade secret or other exemption notation (as applicable; and as provided in Paragraph 28 of the Solicitation Instructions to Vendors), Bidders must also:

· Identify with particularity the precise text, illustration, or other information contained within each page marked “trade secret” or “exempt from disclosure” (it is not sufficient to simply mark the entire page). The specific information you deem “trade secret” or “exempt” within each noted page must be highlighted, italicized, identified by asterisks, contained within a text border, or otherwise clearly delineated from other text/information and specifically identified as a “trade secret” or “exempt from disclosure.”

· Provide a separate document entitled “List of Redacted Trade Secret and Exempt Information” which provides a succinct list of all trade secret and exempt information noted in your Bid; listed in the order it appears in your submittal documents, identified by Page #, Section #/Paragraph #, Title of Section/Paragraph, specific portions of text/illustrations; or in a manner otherwise sufficient to allow the State’s procurement personnel to determine the precise text/material subject to the notation. Additionally, this list must identify with each notation the specific basis for your position that the material be treated as exempt from disclosure and how the exempting the material complies with the Act.

· Submit a redacted copy of any Bid response document (e.g. Scope of Work Response) with all trade secret and exempt information removed or blacked out. The redacted copy must be submitted electronically in the Supplier Attachments section of IPRO, with the word “redacted” in the file name.

Section 3 Evaluation & Award Procedures

3.1 Mandatory Submission Requirements

All Bids will be reviewed on a "pass" or "fail" basis to ensure compliance with all mandatory submission requirements. Bids determined by the State, at its sole discretion, to be responsive in this regard will proceed to the evaluation process outlined in this Section. Bids that do not meet the mandatory submission requirements will be deemed non-responsive. Mandatory submission requirements include, but are not limited to, the following:

· The Bid was submitted prior to the specified Closing Date and Time.

· The Bid complies with the submission instructions detailed in Section 2.4.

· The Bid includes a fully completed and signed Submittal Form A.

· The Bid includes all required Submittal Forms.

3.2 Mandatory Responsibility Requirements

The Bidder shall meet the following requirements to be eligible for award:

· Must have been in business providing truck up fittings for a minimum of seven (7) years.

3.3 Clarification Discussions

The ITB Lead may, in the State’s sole discretion, perform clarification discussions with the Bidder(s) to verify and validate that the Bid will meet the needs of the Agency. At any time during this period, if it is discovered that the Bidder has not met a mandatory requirement, or has failed to adequately respond to an item below, the State may find the Bidder non-responsive, and disqualify the Bid.

The Bidder(s) may be requested to address the following items:

a. Responsibility Assessment: The Bidder may be required to provide documentation to demonstrate its responsibility. Failure to provide the requested documentation may result in the Bidder being deemed non-responsible.

b. Agency Concerns: The Bidder will address or resolve any major risks, issues, concerns, obstacles, or deal-breakers that have been identified by the Agency.

c. Verify the Fee/Cost Bid: The Bidder will clarify and validate the fee/cost schedule. The Bidder will submit any additional financial data, supporting data, or substantiation requested by the Agency.

d. Provide a Project Schedule: The Bidder will provide a detailed schedule of the project (with major milestones or tasks). This should include milestones, task and proposed start and completion dates.

e. Key Assumptions: The Bidder will provide a summary of the major assumptions that have been made in preparing the Bid. This should include items/tasks that the Bidder has assumed the Agency will perform, items/tasks required from the Agency, and items/tasks that have not been included in the Bid (items that the Bidder feels are outside the scope of work). This should also include any critical expectations or responsibilities that the Bidder has of the Agency, Agency personnel, or other parties/organizations that are not contracted to by the Bidder.

f. Technical Reviews: The Bidder will comprehensively describe the approach for meeting all of the requirements in the Scope of Work to confirm depth and breadth of technical and/or industry knowledge, with any efforts required from the Agency should addressed.

g. Reference Verification: If requested, provide a list of references for the firm and each key personnel.

h. Additional Requested Documentation: If requested, provide any additional documentation that may be requested, which may include a detailed project/work plan, testing and commissioning plan, training, change management plan, safety plan, staffing plan, operational plan, maintenance plans, warranties, bonding and insurance, background checks, etc.

The clarification discussion cannot materially alter the Bid. The State does not expect to negotiate any terms or conditions requested by the Bidder, unless they were submitted by the Bidder prior to the deadline for submitting questions (see Section 1.7), or they provide the State an opportunity to secure more advantageous terms or pricing.

3.4 Best-And-Final-Offer (BAFO)

The ITB Lead, in the State’s sole discretion, may conduct discussions and negotiations with multiple Bidders. The ITB Lead may request that these Bidders provide a Best-And-Final-Offer (BAFO) cost Bid. The State reserves the right to conduct one (1) or more rounds of a BAFO with these Bidders. The revised BAFO cost Bids, along with the additional evaluation criteria and weighting outlined in Section 4.2, will be utilized to prioritize and rank the Bidders. If the State anticipates the possibility of awarding multiple contracts from this ITB, the State may engage in concurrent negotiations with apparently successful Bidders as deemed appropriate.

3.5 Award

An award will be made all to one to the lowest responsive and responsible Total Cost as bid on Submittal Form B Pricing Schedule.

3.6 Resulting Contract

If the State awards Contract(s) from this solicitation, it will do so by issuing Contract document(s) from Luma, the State’s ERP system. The State anticipates issuing a single contract document for each awarded Contractor, incorporating the Terms and Conditions, Scope of Work, Appendices, and some or all of the Bidder’s Technical Bid; however, the State reserves the right to determine the form of the resulting Contract(s). A sample contract is provided in Exhibit 6. At its option, the State may memorialize the agreement between the State and each Contractor in one (1) or more final Contract documents.

Important Note: Any modifications or exceptions to the Contract may be rejected by the State. Therefore, the Bidder is strongly encouraged to submit any proposed modifications or exceptions during the Q&A period (see Section 1.7).

EXHIBIT 1 Amended 11/24/2025 Scope of Work

The brand names specified in this solicitation are intended to be descriptive, but not restrictive; indicative of the quality and characteristics of items that meet the minimum requirements. Vendors offering an “equal” must include documentation which demonstrates, to ITD’s satisfaction, that the offered item(s) meets the requirement of the solicitation. In the event documentation is not satisfactory, ITD reserves the right to seek clarification from the Vendor. Failure to provide satisfactory documentation or a clarifying response to ITD may eliminate the Vendor from further consideration.

1. ONE (1) TON TRUCK BODIES AND UPFITTING

ITD provided truck models and installation type.

1.1. Item 1 – DISTRICT 1

1.1.1. One (1) New 2025 Ford F350 4WD crew-cab and chassis, dual rear wheel (DRW), diesel (ITD# T03168).

Up Fitting to include: Stainless Steel Dump-Body, Crane, and Storage Box

1.2. Item 2 – DISTRICT 3

1.2.1. Four (4) New 2025 Ford F350 4WD crew-cab and chassis, DRW, gas (ITD# T03877, T03878, T03879, T03880).

Up Fitting to include: Stainless Steel Dump-Body, liftgate, Storage Box

1.3. Item 3 and Item 4 – DISTRICT 4

1.3.1. Item 3 - One (1) New 2025 Ford F350 4WD crew-cab and chassis, DRW gas (ITD# T03709).

Up Fitting to include: Stainless Steel Dump-Body, Storage Box, Message Board

1.3.2. Item 4 - Three (3) New 2025 Ford F350 4WD crew-cab and chassis, DRW, gas (ITD# T03719, T03730, T03746).

Up Fitting to include: Stainless Steel Dump-Body and Storage Box

1.4. Item 5 and Item 6 – DISTRICT 6

1.4.1. Item 5 - Nine (9) New 2025 Ford F350 4WD crew-cab and chassis, DRW, gas (ITD# T03758, T03763, T03767, T03768, T03779, T03781, T03794, T03795, T03798).

Up Fitting to include: Stainless Steel Dump-Body

1.4.2. Item 6 - One (1) New 2025 Ford F350 4X4 crew-cab and chassis, SRW, gas (ITD# T03753).

Up Fitting to include: Service Body with top boxes and Lift gate

2. BASIC BUILD SPECIFICATIONS

The following basic build specifications apply to all truck up fittings unless otherwise identified in sections 3 through 7.

2.1. HYDRAULICS

2.1.1. All hoses must be high pressure type;

2.1.2. All hoses must be routed in a manner to minimize rub points and bends. Hoses that will rub against metal during the operation of the bodies must be wrapped for protection;

2.1.3. All hoses must be routed to protect them from heat sources and enclosed whenever possible to protect them from damage;

2.1.4. Manufacturers recommended thread sealant must be used on all hydraulic connections. Teflon tape must not be used in the hydraulic system and shall not be accepted;

2.1.5. Hydraulic hoses must not be secured to any factory-installed chassis wiring, cables, hoses, or lines;

2.1.6. Hydraulic hoses must not be secured in the same bundle with any electrical wiring.

2.1.7. Hydraulic hoses must be routed independently;

2.1.8. Hoses must be supported and securely fastened to withstand snow and ice conditions;

2.1.9. Hydraulic components and fittings must be sealed during assembly to prevent system contamination and;

2.1.10. Hose interior must be cleaned prior to installation.

2.2. ELECTRICAL

2.2.1. Must have resettable Circuit Breakers;

2.2.2. All electrical components must be protected by resettable circuit breakers utilizing a dedicated panel. Panel must be a National Electrical Manufacturers Association (NEMA) 6P rated weatherproof box and located in a ground accessible area;

2.2.3. A power disconnect switch must be installed between the truck and the body (dump beds only);

2.2.4. Switch must be completely enclosed so as to not show any exposed terminals or bare wires; and

2.2.5. Switch must be located in an area so as to not interfere with any operation of the vehicle and within reach of the driver’s seat.

2.3. WIRING

2.3.1. Must not be spliced without utilizing weather pack connectors;

2.3.2. Must be securely fastened and located away from all pinch points;

2.3.3. Must be clamped and held in place using stainless steel rubber-insulated, bolt-on cushion clamps;

2.3.4. Passing through bulkheads must be protected with either rubber or neoprene bulkhead wire; protectors and/or body grommet type insert;

2.3.5. Must be run in chemical resistant looms and;

2.3.6. Must have wire identification every six (6) inches. Striped wire of assorted colors is acceptable.

2.4. CABLING

2.4.1. Must be of adequate size to handle the anticipated loads of all electrical components. All cabling must be uninterrupted and complete with no splices;

2.4.2. Terminal ends must be crimped, soldered to the cables and sealed with polyolefin heat shrink tubing. Scotch-Loc fasteners, crimp butt connectors, and wire nuts are not acceptable for any connection;

2.4.3. “Weather-pack” connections must be protected with dielectric grease; and

2.4.4. All electrical cabling to lamps must be stress relieved within six (6) inches of the lamp.

2.5. SWITCHES

2.5.1. OEM switches are to be used unless other arrangements are made with ITD. All switches must illuminate in the ON position and be sealed (weather tight). Switches must be labeled with a permanent placard.

2.6. FASTENERS

2.6.1. All threaded fastener components (bolts, washers, nuts) with a diameter designation greater than or equal to Society of Automotive Engineers (SAE) one half (1/2) inch must be grade eight (8). All nuts must be metal self-locking, lock washers are not acceptable. All bolts must be properly tightened/torqued according to manufacturer’s specification. Tightened bolts must show no less than three (3) threads past nut. All components must have grade identifier marks. All bolts and nuts must be zinc plated.

2.7. WELDING

2.7.1. All exterior joints and seams must be closed with full seam welding. Must be delivered free of weld burn (Wanding Process) and weld splatter and;

2.7.2. Liquid seam seal is not allowed.

2.8. HINGE POINTS

2.8.1. All hinge points with grease zerks must be lubricated prior to delivery.

3. SPECIFICATIONS APPLICABLE TO ITEMS 1.1.1, 1.2.1, 1.3.1, 1.3.2, 1.4.1

3.1. STAINLESS STEEL DUMP BODY

3.1.1. Type – Must be low profile body design with fold down sides;

3.1.2. Size – Outside: Nominal one hundred eight (108) inch length x ninety-six (96) inch width, x twelve (12) inch inside height;

3.1.3. Rated Capacity – two and forty-five hundredths (2.45) yard nominal;

3.1.4. Body must be constructed of 201 No. 4 polished stainless steel and;

3.1.5. Understructure – Must be two (2) stage coating process, prime coated black and undercoated with automotive grade undercoating. (Black paint is not acceptable)

3.2. Body Construction

3.2.1. Underbody Construction – Must be built to withstand seven-thousand four hundred (7,400) pound load capacity;

3.2.2. Floor – Must be sixty-five thousand (65,000) pounds per square inch (PSI) tensile strength. Rear edge of floor must be reinforced to prohibit deflection;

3.2.3. Must be fabricated from a single sheet of three sixteenths (3/16) inch or seven (7) gauge AR 450 sheet steel;

3.2.4. Rear apron must be eight (8) inch high, full width design and fabricated with ten (10) gauge two 201 No. 4 polished stainless steel;

3.2.5. Must have interlocking understructure and longitudinal braces;

3.2.6. Cross members – Must be full width structural channel on twelve (12) inch centers and pass through longitudinal and;

3.2.7. One half (½) inch Stainless steel plate must be welded in place underneath floor (Right rear) for crane support.

3.3. Front Headboard

3.3.1. Must be fabricated from nine-sixty fourths (9/64) inch ten (10 gauge) 201 No. 4 polished stainless-steel material and;

3.3.2. Must be a seamless one-piece design with double bend top rails.

3.4. Cab shield

3.4.1. Must be fabricated from nine-sixty fourths (9/64) inch ten (10 gauge) 201 No. 4 polished stainless-steel material;

3.4.2. Must have laser cut vertical slots extending across center of cab shield for rear viewing;

3.4.3. Side view mirror cutouts – Cab shield must follow truck chassis cab contour to allow for proper rearview sight ability using truck mirrors in the extended position and;

3.4.4. Height of front headboard and cab shield must provide a minimum of four (4) inch clearance between chassis cab roof and cab shield.

3.5. Sides

3.5.1. Must be drop down style, fourteen (14) inch tall maximum, fold down feature controlled by a single lever over center latch;

3.5.2. Lower rub rail must be sloped for self-cleaning purposes;

3.5.3. Top rail must be formed box construction;

3.5.4. Must be fabricated from seven-sixty fourths (7/64) inch twelve (12 gauge) polished stainless-steel;

3.5.5. Must have pin and cam latching system;

3.5.6. Torsion spring used must keep handle in the locked position when not in use;

3.5.7. Side must include three (3) greaseable hinges and;

3.5.8. The force required to operate sides must not exceed fifty (50) pounds.

3.6. Pillars Front/Rear

3.6.1. Must be dirt shedding design and;

3.6.2. Rear pillars must be boxed, smooth and full depth for strength

3.7. Tailgate (EXCEPT WHERE LIFTGATE IS SPECIFIED)

3.7.1. Must be dual function, quick-drop design;

3.7.2. The upper tailgate release lever must offset to curb side for operator safety;

3.7.3. The spring-loaded upper release mechanism must be recessed within the boxed top section of the tailgate to prevent damage during use;

3.7.4. Must be double-walled design with the inner panel;

3.7.5. Top and Bottom Rail must have formed box sections for added strength and rigidity;

3.7.6. Top box section must be dirt shedding design;

3.7.7. Tailgate Top Hinge Pins must be steel shaft and must have all grease zerks lubricated and easy access.

3.7.8. Lower latch pins – must have one (1) inch steel shaft;

3.7.9. Latch fingers –must be one (1) inch thick steel;

3.7.10. Tailgate lower release mechanism – must be grease zerk lubricated;

3.7.11. Spreader and drop Chains – must have an adjustable three-eighths (3/8) inch chain provided to hold the tailgate open for spreading aggregate material;

3.7.12. Tailgate must be the same height as the floor of the Dump Body when in open position;

3.7.13. Weight must not exceed two hundred (200) pounds and;

3.7.14. On trucks that require liftgates, the latches must be removed, and flat stainless-steel plates must be welded in place.

3.8. Body FINISH

3.8.1. All stainless-steel surfaces must be deburred and free from sharp edges.

3.9. Hoist

3.9.1. Type - Direct lift must be a full length sub frame meeting National Truck Equipment Association (NTEA) class C, type one (1) requirements. Scissor type hoist is acceptable if the offered hoist is designed for the provided truck with no modification or interference to chassis when empty or loaded;

3.9.2. Capacity must be eight (8) tons;

3.9.3. Single stage must have a double acting cylinder;

3.9.4. Cylinder shaft must be chromed or nitrated eighty-five thousand (85,000) PSI yield strength;

3.9.5. Maximum operating pressure must be three-thousand two-hundred fifty (3,250) PSI;

3.9.6. Sub-Frame Rails must be constructed from fifty thousand (50,000) PSI yield, sixty five thousand (65,000) PSI tensile strength steel;

3.9.7. Must have greaseable hinges and pins;

3.9.8. Bed must have the capability to be safety pinned in the down position. The pins must be located on the front side of the bed, both right and left sides. Pins must be supplied by the Contractor and;

3.9.9. Must include a body prop to support body weight when empty.

3.10. Hydraulic System

3.10.1. Must be self-contained combination twelve (12) volts direct current (VDC) electric motor direct coupled to hydraulic pump with integral hydraulic reservoir and filter and;

3.10.2. Controls must be in cab, electronically operated stationary momentary “ON” rocker dashboard switch for hoist power up and down. (Installer must contact ITD prior to installation) Location must be made for easy reach of the operator. Remote controller with a minimum of fifteen (15) feet cable must also be provided, wireless controller would also be acceptable.

3.11. Fuel Tank and (or) def Fill Tube Guards

3.11.1. Fill tube guards must be supported and enclosed on three (3) sides, with the bottom open, extended from frame to even with dump body side. Fill tube guards must be made of stainless steel. The fill tubes must be protected from rear tires in the event a failure should occur;

3.11.2. Fuel tubes must be angled up as high as possible to allow fuel to flow freely into tank without spillage and;

3.11.3. Fuel cap must be attached to fill tube with factory supplied or similar lanyard.

3.12. Lights

3.12.1. Must meet all State of Idaho requirements and Federal Motor Vehicle Safety Standards (FMVSS) and;

3.12.2. Rear stop, turn, and taillights must have two (2) red, LED type, six (6)-inch oval, grommet mounted combination stop, turn, and taillight heads equipped with “weather-pack” electrical wiring connector for quick replacement.

3.12.3. Body must be equipped with clearance lights.

3.13. Reverse lights

3.13.1. Must have two (2) white, LED six (6)-inch oval, grommet mounted reverse lights equipped with “weather-pack” electrical wiring connector for quick and easy replacement. Lights must be stand alone and not combined with any other rear facing lights.

3.14. License plate lamp

3.14.1. Must be LED type.

3.15. Warning Lights

3.15.1. Must have two (2) WHELEN fifteen (15) inch LED minibar warning lights (model # R2LPPA) brand name or equal, with three-hundred sixty (360)-degree warning, seventy-five (75) flashes per minute (FPM) flash pattern, rated twenty-twenty four (12-24) VDC, and synchronized to operate simultaneously. Lights must be horizontally installed on the cab shield, side by side, and spaced as far apart as possible. Light mounts must be fabricated from stainless steel or aluminum;

3.15.2. Front- Must have two (2) WHELEN model TLIA, (ION T Series) brand name or equal. Surface Mount amber lights. Lights must be horizontally installed on front grill, forward facing, as high inside grill as possible to fit, each spaced as far apart as possible. Lights must be installed level with each other in the same row on the grill;

3.15.3. Rear- Must have two (2) WHELEN model TLIA (ION T Series) brand name or equal. Surface Mount amber lights. Lights must be horizontally installed on the rear of the truck, no more than four (4) feet off ground and spaced as far apart as possible, level with each other and;

3.15.4. All warning lights must be wired to a single switch through a relay and actuated from the driver’s position using the original equipment manufacturer (OEM) upfitter switch. Must be wired to the OEM highest amperage, always “hot” switch. Switch must be labeled. ITD must approve the labeling of the switch upon award of the contract.

3.16. TOOLBOX

3.16.1. Belly type, BUYERS #1702605 brand name or equal;

3.16.2. Type – Underbody, must be stainless steel construction;

3.16.3. Size must be thirty-six (36) inch length by eighteen (18) inch height by eighteen (18) inch depth;

3.16.4. Door – Must be single, drop down;

3.16.5. Material – must be fourteen (14)-gauge 300 series stainless steel construction with 2B finish;

3.16.6. Latch – must be stainless steel T-handle, single point latch with adjustable tension plate;

3.16.7. Seal – Must be continuous bulb type;

3.16.8. Drop chains must be stainless steel;

3.16.9. Location - Curbside

3.16.10. Mounting – Must have two (2) three (3) inch, stainless steel c-channel, welded to truck frame, and mounted with four (4) three quarter (3/4) inch Grade eight (8) bolts top left and top right sides of toolbox and;

3.16.11. Outside coating - Must have a hot, high pressure polyurethane coating specified at One-Hundred Twenty-Five (125) millimeter on the side facing the rear wheels and ninety (90) millimeter on all other sides, must be applied to the exterior of the toolbox excluding the door. Surface must be sanded, and primer coated prior to application. (LINE-X brand name or equal) Cold or roll-on systems are not acceptable.

3.17. Mud Flaps

3.17.1. Must be twenty-four (24) inch by thirty (30) inch, anti-spray/anti-sail type without logos or writing and;

3.17.2. Rear mud flaps must be mounted providing a clearance from ground to bottom of mud flap of no less than ten (10) inch and not to exceed eleven (11) inch.

3.18. Hitch

3.18.1. One (1) BUYERS model 1801051L 1801060L brand name or equal, sixteen thousand (16,000 pound) receiver hitch complete with the following:

3.18.1.1. BUYERS model PM107 brand name or equal, pintle hook mount and hitch pin;

3.18.1.2. BUYERS model BH82000 brand name or equal, eight (8)-ton, two (2) inch combo hitch and;

3.18.1.3. POLLAK model 12-707 brand name or equal seven (7) pole trailer connector with flat terminals (RV style), equipped with PHILLIPS model 15-740 brand name or equal, rubber boot.

3.19. Fire Extinguisher

3.19.1. Must have one (1), two and a half (2-1/2) pound ABC type, with metal bracket and locking latch mounted next to or behind driver’s seat.

3.20. Back up camera

3.20.1. The contractor must install the provided FORD OEM Camera included with the truck. (P/N 872).

3.21. Telematics Box

3.21.1. Must install one (1) supplied box (GEOTAB) to OBDII Connector supplied by ITD. Contractor must leave the component box in glove compartment as it contains needed bar codes. ITD plate number written on box must correspond to vehicle plate number.

3.22. ICC Bumper

All dump beds listed is section 3 require an interstate commerce commission ICC (Mansfield) Bar at the rear of the dump bodies welded to the back plate with integrated hitch in section 3.18 . (Picture provided for reference only as Exhibit 9)

4. SPECIFICATIONS APPLICABLE TO ITEMS 1.1.1

4.1. Crane

4.1.1. LIFTMOORE model 206 REL, brand name or equal;

4.1.2. Must be installed on the dump bed, right rear side;

4.1.3. Must have a Six-thousand five hundred (6500) foot-pound moment rating, two thousand (2000) pound max capacity;

4.1.4. Must be Powered by twelve-volt (12v) DC. With Master Switch using OEM upfitter switch;

4.1.5. Cable must be thirty-five (35) feet of three sixteenths (3/16) inch galvanized aircraft cable with four-thousand two hundred (4200) pound breaking strength;

4.1.6. Must include removable pendant control with a minimum of seven (7) feet lead;

4.1.7. Must be attached to one-half (½) inch stainless steel mounting plate and reinforced from the underside with an additional one half (½) inch stainless steel plate. Plate mounting must be engineered to prevent any catastrophic failures that could cause harm to the operator or vehicles; and must be welded in place and braced proportionately if determined to be necessary by engineer;

4.1.8. Installation must be professionally engineered to prevent failure;

4.1.9. Crane must be able to be locked in place when stowed and;

4.1.10. A removable boom cradle mount with locking strap must be installed in bed on curbside. Mount must be pinned in place for easy removal. Prior to cradle mount installation Contractor must contact ITD for design/installation approval.

4.1.11. Truck must be made LEVEL to accommodate the weight of the crane. This may include, but not be limited to, adding one (1) or more extra leafs to the vehicle spring pack.

4.1.12. Truck body must be able to support crane while in the UP position without any strain on the hydraulic system or frame work.

4.1.13. Truck Body must include an adjustable jackleg under the right rear of dump bed on vehicles that require cranes, which must be able to support a minimum of three thousand (3,000) pounds.

4.1.14. Maximum weight of crane and pedestal must not exceed five hundred (500) lbs.

5. ADDITIONAL SPECIFICATIONS APPLICABLE TO ITEM 1.3.3

5.1. Message Board

5.1.1. Manufacture – LITESYS brand name or equal;

5.1.2. Model – LiteReader VCMS Model 1020F-4 brand name or equal;

5.1.3. Small characters: two (2) Lines of ten (10) inch characters;

5.1.4. Mount – Litesys, brand name or equal, three hundred sixty (360) degree, Powered swivel mount with handheld controller;

5.1.5. Must be mounted on top of body cab guard;

5.1.6. Controller must be mounted inside truck cab with raised mount, located center floor area;

5.1.7. Controller must not be mounted to dashboard;

5.1.8. Specifications must meet MUTCD Type B;

5.1.9. Headboard lights (Whelen R2LPPA, brand name or equal) must be fully visible three hundred sixty (360) degrees with message board in stowed and deployed position;

5.1.10. Must be circuit protected using OEM (original equipment manufacturer) Upfitter switches and wired to always (HOT) and;

5.1.11. Switch must be labeled with permanent placard.

6. ADDITIONAL SPECIFICATIONS APPLICABLE TO ITEM 1.4.2

6.1. SERVICE BODY

6.1.1. Must have a standard service body;

6.1.2. Must fit 2025 Ford F350 Crew Cab, SRW, sixty (60) CA.;

6.1.3. Manufacture – READING service body, Model CLASSIC II – STEEL, brand name or equal;

6.1.4. Color must be White to match OEM;

6.1.5. Size length must be one hundred eight inches (108) inches with a maximum allowable deviation not to exceed two (2) inches;

6.1.6. Width must be ninety-one and one half (91-1/2) inches with a maximum allowable deviation not to exceed two (2) inches;

6.1.7. Height must be forty inches (40) inches with a maximum allowable deviation not to exceed two (2) inches;

6.1.8. Must have SPACEMAKER brand name or equal top boxes;

6.1.9. Must have no raised wheel wells in truck bed;

6.1.10. Undercoating entire under body must be coated with an asphaltic material;

6.1.11. All interior boxes must have LED lighting controlled with a circuit/fuse protected single switch.

6.1.12. Bumper

6.1.12.1. Bumper must be diamond plated;

6.1.12.2. Must have a poly-urethane nonskid coating applied at one hundred twenty (120) millimeter thickness. Product must be a LINE-X brand or equal coating. Cold application shall be rejected.

6.1.13. Tow receiver must be Class V;

6.1.14. Trailer plug must be round seven (7) pin electrical light/brake connector;

6.1.15. Mud flaps must be Twenty-four (24) inch by thirty–six (36) inch. Anti-spray, anti-sail type without logos or writing;

6.1.16. Rear mud flaps must be mounted providing a clearance from ground to bottom of mud flap of no less than ten (10) inch and not to exceed eleven (11) inch and;

6.1.17. Warranty must be for a minimum of a six (6) year warranty against any factory related items.

6.2. WARNING LIGHTS

6.2.1. Must have one (1) WHELEN fifteen (15) inch LED light-bar warning lights (model # R2LPPA), brand name or equal, with three hundred sixty (360)-degree warning, seventy-five (75) flashes per minute (FPM) flash pattern, rated twelve twenty-four (12-24) VDC, and synchronized to operate simultaneously. Light must be horizontally installed on an ACARI LP Series, brand name or equal, twenty-eight (28) inch light mount;

6.2.2. 3rd brake light must be installed on rear of light mount in section 6.2.1.

6.2.3. Must have two (2) RIGID SRQ, brand name or equal, six (6-LED bulb) Pro driving lights, to be mounted on either side of the light-bar in section 6.2.1, facing to the side;

6.2.4. Must have two (2) WHELEN model IONA brand name or equal, amber lights. Lights must be horizontally installed inside front grill, forward facing, as high inside grill as possible to fit, each spaced as far apart as possible. Lights must be installed level with each other in the same row on the grill;

6.2.5. Must have two (2) WHELEN model TLIA (ION T Series), brand name or equal, Surface Mount amber lights. Lights must be horizontally installed on the rear of the truck, no more than four (4) feet off ground and spaced as far apart as possible, level with each other;

6.2.6. All warning lights must be wired to a single switch through relays and actuated from the driver’s position using the original equipment manufacturer (OEM) upfitter switch. Must be wired, always “hot.”;

6.2.7. Both RIGID PRO, brand name or equal, lights must be individually wired to separate OE upfitter switches, wired to always “hot.” and;

6.2.8. Switches must be labeled. ITD must approve the labeling of the switch upon award of the contract.

6.3. SPRAY ON BED COATING

6.3.1. Must be the same properties as LINE-X Brand (Black), brand name or equal. Must be a hot polyurethane system with the same tinsel strength (cold sprayed products will not be accepted);

6.3.2. Must be one hundred twenty-five (125) millimeter thickness on topside floor, Ninety (90) millimeter thickness on inside bed walls and;

6.3.3. Must be one hundred twenty-five (125) millimeter thickness on top of rear bumper.

6.4. Fire Extinguisher

6.4.1. Must have one (1), two and a half pound (2-1/2 pound) ABC type Fire , with metal bracket and locking latch mounted next to or behind driver’s seat.

6.5. Back up camera

6.5.1. Contractor must install the provided FORD OEM Camera included with the truck. (P/N 872).

6.6. Telematics Box

6.6.1. Must install one (1) supplied box (GEOTAB) to OBDII Connector supplied by ITD. Contractor must leave component box in glove compartment as it contains needed bar codes. ITD plate number written on box must correspond to vehicle plate number.

7. ADDITIONAL SPECIFICATIONS APPLICABLE ONLY TO 1.4.2 AND 1.2.1

7.1. Lift Gate

7.1.1. Tommygate – G2Series, brand name or equal, for Pick-up Trucks;

7.1.2. Must have a one thousand three hundred (1300) pound capacity;

7.1.3. Must have aluminum platform;

7.1.4. Must have dual Cylinders and;

7.1.5. Must have bolt-on rear LED light kit.

7.2. Lift Gate

7.2.1. Tommygate – G2 Series, brand name or equal, for Dump beds;

7.2.2. Must have a one thousand three hundred 1600 pound capacity;

7.2.3. Must have aluminum platform;

7.2.4. Must have dual cylinders and;

7.2.5. 6.9 Bolt-on rear LED light kit.

8. ADDITIONAL REQUIREMENTS APPLYING TO ALL ITEMS IN THIS ITB

Note: In the event of conflict with the State’s Standard Terms and Conditions, or other terms, conditions or requirements contained in this ITB, the following provisions will take precedence:

8.1. WARRANTY

The Up-Fitting, including all accessories, must be warranted against all defects in material and workmanship by either the manufacturer or the Contractor for a period of no less than one (1) year, with exception to the lights, which must be warranted for a period of no less than five (5) years. Service Body Warranty must meet the minimum timeframe as published in Section 6.1.17.

Warranty period must commence on the date that the Up-Fitting is accepted by ITD. If manufacturer’s warranty for any product installed does not cover the minimum warranty period from the date ITD accepts delivery, Contractor must warranty and be responsible for repairing or replacing the products for the remaining period of the minimum warranty required in this contract.

Warranty must include all parts, labor, and freight to replace a defective warranted item. All warranty work must be completed within fourteen (14) calendar days after receipt of notice from ITD.

If any warranty work is to be performed, the Contractor may elect to authorize a dealer of its choice or authorize ITD to perform the necessary repairs in accordance with the manufacturer’s standards. If the Contractor authorizes ITD to perform any warranty work: 1) it is the responsibility of the Contractor to guarantee that the work is completed in accordance with the manufacturer’s standards at the expense of the Contractor, 2) completion of warranty repairs by ITD which are authorized by the Contractor will not adversely affect the warranty, and 3) the Contractor shall reimburse ITD for the cost of the warranty repairs (parts, labor, and materials) within sixty (60) calendar days after notice.

8.2. Deliveries

Delivery Location: ITD Headquarters, 3311 West State Street, Boise, ID 83703.

All vehicle upfitting’s must be delivered to the delivery Location above withing one hundred and eighty (180) days after receipt of order (ARO). ITD shall initiate order by issuing a Purchase Order Document.

Delivery Times: Delivery must be made Monday through Thursday 8:00 am to 4:00 pm Mountain Time. Deliveries will not be accepted during state of Idaho recognized holidays, or outside of this timeframe, unless otherwise approved in writing by the Contract Management Team (CMT).

For Contractors with installation facility (where work under this Contract will be performed) located within twenty-five (25) miles of the Delivery Location: ITD will be responsible for delivering its vehicles to the Contractor’s installation facility. ITD will be responsible for picking up its vehicles with the installed equipment from the Contractor’s installation facility.

For Contractor with installation facility (where work under this Contract will be performed) located more than twenty-five (25) miles from the delivery location: The Contractor will be responsible for picking up ITD’s vehicles from the delivery location. The Contractor will be responsible for delivering ITD’s vehicles back to the delivery location. The Contractor must haul (not drive or tow) ITD vehicles while transporting between locations. All expenses related to transporting ITD vehicles, including risk in transit, are the responsibility of the Contractor and must be included in its fully burdened price.

The Contractor must store ITD vehicles in locked and secure manner either inside a fenced parking area or inside the Contractor’s facility when Contractor personnel are not on site to ensure protection of the vehicles.

All vehicles must be washed (exterior) and cleaned (interior) prior to delivery. Dirty vehicles will not be accepted.

8.3. Tariff Costs

If the President of the United States, the United States Congress, Customs and Border Protection, or any other federal entity authorized by law, imposes an import duty or tariff (a “tariff”) on an imported good that results in an increase in Contractor’s costs to a level that renders performance under this Agreement impracticable, Contractor may be permitted to add up to fifty percent (50%) of the actual and verifiable cost it directly incurs due to tariffs to its invoices submitted to the State, subject to the following conditions:

1. ITD must have sufficient appropriation to pay any tariff costs.

2. Contractor shall promptly notify ITD of the maximum cost of tariffs and obtain ITD’s prior written approval for payment of any tariff costs. ITD shall not be obligated to pay tariff costs for which ITD did not provide prior written approval, for which ITD does not have sufficient appropriation, or which exceed the approved maximum. Contractor may provide notification of maximum tariffs on a case-by-case basis (for each order) or may provide blanket or time-bound notification (e.g., maximum for any orders placed for the next six (6) months).

3. Contractor shall take reasonable steps to avoid or minimize incurring tariffs and may be asked to provide a certification confirming its efforts and supporting documentation to ITD.

4. Contractor may only invoice for actual approved tariff costs, even if that amount is less than the approved maximum.

5. The invoice must be supported by accurate documentation confirming the actual cost and applicability of tariffs, which may include country of origin, order/delivery dates, official tariff rates, declared value, supplier or manufacturer invoices, etc.

6. If applicable tariffs are subsequently reduced or eliminated, Contractor will promptly notify Agency and invoices must reflect such change.

Any material misrepresentation of fact by Contractor relating in any way to an increase in pricing due to tariffs is a default under this Contract and shall be subject to the remedies set forth herein, in addition to any other claim or remedy available to the State. Furthermore, any material misrepresentation of fact by Contractor relating in any way to ITD’s payment of additional sums due to tariffs shall be fraud against the taxpayers of the State and grounds for the Contractor to be deemed non-responsible and/or disqualified from participation in future solicitations administered by the State.

8.4. Records Maintenance

Contractor shall maintain or supervise the maintenance of all records necessary to properly account for all payments made to the Contractor pursuant to the Contract. These records shall be retained by the Contractor for at least three (3) years after the Contract terminates, or until all audits initiated within the three (3) years have been completed, whichever is later.

8.5. Audit Rights

The Contractor agrees to allow State and Federal auditors and State purchasing staff access to all the records relating to this Contract, for audit, inspection, and monitoring of services or performance. Such access will be during normal business hours or by appointment.

EXHIBIT 2

Acronym List

ONE-TON TRUCK BODIES AND UP FITTING

AM/FM
Amplitude Modulation / Frequency Modulation
ANSI
American National Standards Institute
ARO
After Receipt of Order
CD
Compact Disk
dBA
A-Weighted Decibels
DC
Direct Current
DOP
Division of Purchasing
DOT
Department of Transportation
FMVSS
Federal Motor Vehicle Safety Standards
FOB
Free on Board
GFI
Ground Fault Interrupter
GPM
Gallons per Minute
GPS
Global Positioning System
H.P.
Horsepower
Hz
Hertz
IPRO
Idaho Electronic Procurement System
ITB
Invitation to Bid
ITD
Idaho Transportation Department
KML
Keyhole Markup Language
LCD
Liquid Crystal Display
LED
Light-Emitting Diode
MPH
Miles per Hour
MSO
Manufacture’s Statement of Origin
NEMA
National Electrical Manufacturers Association
PDF
Portable Document Format
PSI
Pounds per Square Inch
PTO
Power Take Off
RBM
Resisting Bending Moment
RPM
Rotations per Minute
SAE
Society of Automotive Engineers
USB
Universal Serial Bus
UV
Ultra-Violet
OBD II
On Board Diagnostic Generation 2
P/N
Part Number
VDC
Volts of Direct Current

EXHIBIT 6

Contract

The Contract resulting from this solicitation is subject to the terms and conditions set forth in the document titled “State of Idaho Contract Terms and Conditions” attached within the Questions tab in IPRO Powered by LUMA. By executing a Contract resulting from this solicitation, the parties acknowledge and agree to be bound by all such terms and conditions as if fully set forth herein.

The Contract incorporates by reference all attachments, exhibits, and documents included in the original solicitation, as well as all attachments, exhibits, and materials submitted by the Contractor in response to the solicitation.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .