Intrinsically Safe Borescope Salient Characteristics.pdf

PDF 113 KB Posted

Attached to
Class I Division 1/2 Borescope Federal contract opportunity
Solicitation number
FA4460-24-Q-0262
Issued by
Department of the Air Force Air Mobility Command

About this file

This document is the Intrinsically Safe Borescope Salient Characteristics for a federal contract opportunity. The purpose of the intrinsically safe borescope is to enable Fuel System Repair Technicians to troubleshoot venting aircraft by identifying leaking components in the vent system. The desired outcome is a portable, handheld borescope that displays high-resolution pictures/video feed, is Class I Division 1 or 2 rated for hazardous areas, and is resistant to oil, water, and dust. The required specifications include a display of at least 5 inches and 640x480 resolution, a camera with lights, a rechargeable battery and/or corded power supply, a camera length of at least 10 meters, at least 32GB of storage, a camera diameter of at least 8mm, a weight of no more than 3lbs, and operating temperatures between -13F to 176F. The related federal contract opportunity is Solicitation FA4460-24-Q-0262 issued by the Department of the Air Force Air Mobility Command to purchase a Class I Division 1/2 Borescope that meets these salient characteristics.

View the file

Other files for this federal contract opportunity

Other files attached to Class I Division 1/2 Borescope, newest first.
File Type Posted
Clauses and Provisions.pdf PDF
52.212-1 & 2 Addendum.docx DOCX document
Combo Synopsis Solicitation.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INTRINSICALLY SAFE BORESCOPE SALIENT

CHARACTERISTICS

PURPOSE

The intrinsically safe borescope, although not required by tech data, does enable Fuel System Repair Technicians to troubleshoot venting aircraft by entering the system through the vent mast to identify which specific component is leaking.

This equipment is required by TO 1-1-3 paragraph 2.7.5.6 Other Electrical Equipment to be approved by component authority for National Electric Code Class I, Division 1 or 2 hazardous areas. This is a must for the equipment purchased to be used for this intended use.

Desired Outcome: Portable, handheld borescope that displays high-resolution pictures/video feed transmitted from a camera inserted into the vent system of the C-130J. It must be deemed Class I, Division 1 or 2 and be resistant to oil, water, and dust. It should have a 360-degree articulating camera.

Characteristics:

Display: Not less than 5 in and not less than 640x480 resolution

Camera: Must have lights on camera for visibility

Power Source: Rechargeable battery and/or chorded power supply

Camera Length: Not less than 10 meters

Storage: Not less than 32GB

Camera Diameter: Not less than 8mm

Weight: Not more than 3lbs

System Operating Temperature: -13°F to 115°F

Tip Operating Temperature: -13°F to 176°F

Storage Temperature: -13°F to 140°F

File details come from the government source that posted it. Updated .