industrial blvd lift station sewer ext_plans_.pdf
PDF 13 MB Posted
- Solicitation number
- PE-70750-NONST-2027-000000075
- Issued by
- Newton County, Georgia
About this file
This document comprises construction plans and specifications for the Industrial Boulevard Lift Station Sewer Extension project issued by the City of Covington, Georgia (Bid No. 2026-14). The project involves the installation of approximately 1,165 linear feet of new 8-inch sanitary sewer infrastructure, including open-cut polyvinyl chloride (PVC) and ductile iron pipe (DIP), as well as directional drilling utilizing 8-inch high-density polyethylene (HDPE) pipe. The work scope includes construction of new sanitary sewer manholes, connections to the existing sewer system, bypass pumping to maintain service during construction, adjustment of existing manholes to grade, and installation of associated fittings and appurtenances. The project is located at Industrial Boulevard in Covington, Georgia (Land Lot 274, Newton County), on approximately 0.76 acres, and is not located within a FEMA floodplain. Sealed bids were received until 10:00 a.m. on Thursday, August 27, 2026, at Covington City Hall, 2194 Emory Street NW, Covington, GA 30014, with public bid opening at 2116 Stallings Street NW. The primary contact is Robert Barber, Water and Sewer Manager, at (678) 414-1434.
The construction documents specify detailed requirements for trench safety, utility coordination, dewatering, erosion and sediment control, and inspection protocols. All construction must conform to City of Covington standards and applicable specifications, with the contractor responsible for coordinating work with the city, obtaining Georgia 811 utility locates a minimum of three business days before excavation, and maintaining bypass pumping throughout construction. The contractor must provide temporary erosion control measures, including silt fencing and sediment traps, prior to or concurrent with construction commencement and maintain all disturbed areas with appropriate stabilization and seeding. Shop drawings and product certifications are required for all materials prior to ordering. Following substantial completion, the contractor must provide a record survey and CAD file prepared by a Georgia-registered land surveyor to document sewer alignment, manhole locations, pipe specifications, and site features. The contractor bears responsibility for all costs associated with bypass pumping, dewatering, utility relocation, road repairs, monitoring well buffer maintenance, and site restoration.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| industrial blvd lift station sewer ext_specs_.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SITE INFORMATION
LANDLOT 274 OF UNKNOWN LAND DISTRICT
LATITUDE: 33.612635 LONGITUDE: -83.833425
THIS PROJECT IS NOT LOCATED WITHIN A FLOODPLAIN, PER FEMA
FLOOD MAP PANEL 13217C0127D, EFFECTIVE DATE: 03-17-2014
PROJECT ISSUE SEQUENCE
GWES PROJECT NUMBER: 060.29.1.25
INDUSTRIAL BOULEVARD LIFT STATION: SEWER EXTENSION
FOR THE
CITY OF COVINGTON
2194 EMORY STREET NW, COVINGTON, GEORGIA 30014
24-HOUR CONTACT: ROBERT BARBER,
WATER AND SEWER MANAGER
TELEPHONE: (678) 414-1434
EMAIL: RBARBER@CITYOFCOVINGTON.ORG
CITY OF COVINGTON BID NO. 2026-14
VICINITY MAP
SCALE: N.T.S.
IN
DU
ST
RI
AL
B
LV
D
I-20
GA
-1
ALC
OVY RD
PROJECT
AREA
NO. DATE DESCRIPTION
I-20
GA
-14
HA
ZE
LB
RA
ND
R
D
NE
HWY 278 NE
EM
OR
Y
ST
HWY 81
JACKSON HWY
ALC
OVY RD
INDUSTRIAL
DR NE
HWY 278 NE
DRAWING INDEX
DRAWING NO. SHEET TITLE
CV-1 COVER
C-1 GENERAL NOTES, CONSTRUCTION NOTES, LEGEND, AND ABBREVIATIONS
C-2 KEY MAP
C-3 EXISTING CONDITION AND DEMOLITION
C-4 SITE PLAN
C-5 PROFILES
C-6 PROFILES
C-7 CONSTRUCTION DETAILS
C-8 ESPCP DETAILS
C-9 ESPCP DETAILS
0 7/7/26 ISSUE FOR BID
SS->
LEGEND
STORMWATER PIPING
TREE
CONTROL POINT
BENCHMARK
SANITARY SEWER W/ MANHOLE
PROPERTY LINE W/ PIN
EXISTING PROPOSED
LOD LODLIMITS OF CLEARING
AND CONSTRUCTION
OHP
W
OVERHEAD POWER/POWER POLE
WATER LINE
GAS METER
GRAVEL
FIRE HYDRANT
ASPHALT PAVING
LIGHT POLE/GUY WIRE
SIGN
IPF
S
VALVE
18" HARDWOOD
TREELINE
MAIL BOX
GM
HEADWALL
FLARED END SECTION
CONTOUR
SILT FENCE
XXXXXX
400 400
REMOVE AND REPLACE
SS->
TELEPHONE PEDESTAL
FIBER OPTIC MARKER
RIGHT OF WAY (R/W)
EASEMENT
CFS - CUBIC FEET PER SECOND
CONC - CONCRETE
CMP - CORRUGATED METAL PIPE
CP - CONTROL POINT
DIP - DUCTILE IRON PIPE
EL - ELEVATION
ESPCP - EROSION, SEDIMENTATION, AND POLLUTION CONTROL PLAN
GDOT - GEORGIA DEPARTMENT OF TRANSPORTATION
HDPE - HIGH-DENSITY POLYETHYLENE
INV - INVERT
LF - LINEAR FEET
PVC - POLYVINYL CHLORIDE
OC - ON CENTER
FPS - FEET PER SECOND
RCEP - REINFORCED CONCRETE ELLIPTICAL PIPE
RCP - REINFORCED CONCRETE PIPE
SF - SQUARE FEET
MH - MANHOLE
STD - STANDARD
SY - SQUARE YARDS
STA - STATION
TYP - TYPICAL
VF - VERTICAL FEET
ABBREVIATION LEGEND
GENERAL NOTES:
1. CONTRACTOR TO COORDINATE ALL CONSTRUCTION WITH THE OWNER, CITY OF COVINGTON. ADDRESS IS 2194 EMORY STREET NW, COVINGTON, GEORGIA 30014. 24-HOUR CONTACT ROBERT BARBER, (678) 414-1434.
2. ALL CONSTRUCTION SHALL CONFORM TO THE PLANS, SPECIFICATIONS, AND CITY STANDARDS. IN THE EVENT OF CONFLICTS, THE
STRICTER OF THE STANDARDS SHALL APPLY.
3. ANY REFERENCE TO “CONTRACTOR” SHALL BE ASSUMED TO ALSO APPLY TO ANY AND ALL OF THE CONTRACTOR'S VENDORS, SUPPLIERS, AND SUBCONTRACTORS.
4. THIS PROJECT IS LOCATED IN UNKNOWN DISTRICT/LAND LOT 274 OF NEWTON COUNTY, GA. THIS PROJECT IS NOT LOCATED WITHIN A
FLOODPLAIN PER FEMA MAP PANEL(S) 13217C0127D, EFFECTIVE DATE:03-17-2014.
5. THE LOCATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS HAVE BEEN DETERMINED FROM THE BEST AVAILABLE INFORMATION AND IS GIVEN FOR THE CONVENIENCE OF THE CONTRACTOR. ENGINEER AND OWNER DO NOT ASSUME RESPONSIBILITY OF THE
ACCURACY OF THE LOCATIONS SHOWN.
6. THE TOPOGRAPHIC SURVEY WAS PREPARED BY STRANGE LAND SURVEYING, INC. DATED 08-14-2025. STRANGE LAND SURVEYING, INC.
NOR THE LICENSED PROFESSIONAL ASSUME ANY LIABILITY FOR THE EXISTENCE, LOCATION, MATERIAL OR SIZE OF ANY UNDERGROUND UTILITY SHOWN ON THIS SURVEY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE, EXACT LOCATION, MATERIAL AND SIZE OF ANY UNDERGROUND UTILITY BEFORE BIDDING OR EXCAVATING ON THIS PROJECT. THE TOPOGRAPHIC AND ELEVATION DATA SHOWN HEREON WAS OBTAINED FROM STRANGE LAND SURVEYING, INC. AND IS NOT CERTIFIED AS CORRECT BY THIS
ENGINEER. USERS OF THIS DATA DO SO AT THEIR OWN RISK.
7. THE CONTRACTOR SHALL CONTACT GEORGIA 811 EITHER BY DIALING 811 OR BY SUBMITTING A DIG TICKET ONLINE, A MINIMUM OF THREE (3) BUSINESS DAYS PRIOR TO THE START OF ANY EXCAVATION ACTIVITIES. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED INFORMATION, INCLUDING CONTACT INFORMATION, EXACT WORK LOCATION, DIRECTIONS TO SITE, TYPE OF WORK TO BE PERFORMED, ANTICIPATED START DATE, AND EXPECTED DURATION OF WORK. THE CONTRACTOR SHALL ALLOW UTILITY OWNERS THE LEGALLY REQUIRED RESPONSE TIME TO LOCATE AND MARK UNDERGROUND UTILITIES AND SHALL VERIFY ALL UTILITY RESPONSES THROUGH THE POSITIVE RESPONSE INFORMATION SYSTEM (PRIS) BEFORE COMMENCING ANY WORK. EXCAVATION SHALL NOT BEGIN UNTIL ALL UTILITIES HAVE RESPONDED AND NO UNMARKED BUT VISIBLY APPARENT UNDERGROUND UTILITIES ARE PRESENT. IF UTILITY MARKINGS ARE MISSING, UNCLEAR, OR RESPONSES ARE INCOMPLETE, THE CONTRACTOR SHALL CONTACT GEORGIA 811 FOR RE-NOTIFICATION PRIOR TO PROCEEDING. ALL EXCAVATION ACTIVITIES SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE TOLERANCE ZONE REQUIREMENTS AND SAFE DIGGING PRACTICES, PARTICULARLY WHEN OPERATING MECHANIZED EQUIPMENT.
8. THE CONTRACTOR SHALL VERIFY LOCATIONS AND SIZES OF EXISTING UTILITIES. IF A DISCREPANCY EXISTS WITH THE UTILITY LOCATIONS, THE CONTRACTOR SHALL CONTACT THE OWNER BEFORE BEGINNING CONSTRUCTION. CONTRACTOR TO VERIFY ALL POTENTIAL UTILITY CONFLICTS AND SHALL IMMEDIATELY NOTIFY THE OWNER OF ANY DISCREPANCIES BETWEEN THE PLANS AND THE
ACTUAL FIELD CONDITIONS.
9. THE CONTRACTOR SHALL RETAIN A LICENSED SURVEYOR TO PROVIDE THE HORIZONTAL AND VERTICAL CONTROL DATA FOR THE PROJECT. BENCHMARK AND SURVEY CONTROL POINT INFORMATION SHALL BE PROVIDED TO THE CONTRACTOR BY THE OWNER OR OWNER'S SURVEYOR. DISCREPANCIES BETWEEN FIELD MEASUREMENTS AND CONSTRUCTION PLAN INFORMATION SHALL BE BROUGHT
TO THE ATTENTION OF THE OWNER IMMEDIATELY.
10. ANY REFERENCE POINTS, RIGHT-OF-WAY MONUMENTS, PROPERTY CORNERS, BENCHMARKS OR OTHER MONUMENTS DISTURBED AS A RESULT OF CONSTRUCTION SHALL BE RESTORED BY A REGISTERED LAND SURVEYOR LICENSED TO PRACTICE IN THE STATE OF GEORGIA, WITH ALL ASSOCIATED COSTS BORNE BY THE CONTRACTOR. LIKEWISE, ALL LANDSCAPES, STREET SIGNS, MAILBOXES, TRAFFIC SIGNS AND OTHER STREET FURNITURE AND APPURTENANCES DISTURBED BY CONSTRUCTION OPERATIONS SHALL BE
RESTORED BY THE CONTRACTOR TO THEIR ORIGINAL CONDITION.
11. ALL CONSTRUCTION ON PRIVATE PROPERTY REQUIRES A TEMPORARY OR PERMANENT EASEMENT. THE OWNER WILL OBTAIN SUCH
EASEMENTS.
12. THE CONTRACTOR SHALL NOTIFY APPROPRIATE INSPECTORS AT LEAST 2 BUSINESS DAYS PRIOR TO COMMENCING CONSTRUCTION.
CONTRACTOR SHALL COORDINATE WORK SCHEDULE DAILY WITH INSPECTORS ONCE CONSTRUCTION COMMENCES UNTIL PROJECT COMPLETION. CONTRACTOR SHALL REVIEW WORK COMPLETED QUANTITIES WITH INSPECTORS PRIOR TO SUBMISSION OF MONTHLY
PAY APPLICATION REQUEST.
13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ARRANGING AND SECURING ANY NECESSARY STORAGE AND STAGING AREAS FOR CONSTRUCTION EQUIPMENT AND MATERIAL. SECURITY OF EQUIPMENT AND MATERIAL SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR.
14. CONSTRUCTION AND STORAGE AREAS SHALL BE KEPT NEAT AND CLEAN AT ALL TIMES.
15. SHOP DRAWINGS AND CERTIFICATIONS FOR ALL CONSTRUCTION MATERIALS ARE REQUIRED. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND PRODUCT LITERATURE TO THE ENGINEER FOR REVIEW PRIOR TO ORDERING THE MATERIALS REQUIRED FOR
CONSTRUCTION.
16. THE CLEARING AND CONSTRUCTION LIMITS ARE SHOWN ON THE PLANS. THE CONTRACTOR SHALL CONTAIN ALL CONSTRUCTION ACTIVITIES WITHIN THESE LIMITS. AT NO TIME SHALL THE CONTRACTOR DISTURB SURROUNDING PROPERTIES OR TRAVEL ON SURROUNDING AREAS WITHOUT WRITTEN CONSENT FROM THE OWNER AND THE PROPERTY OWNER. ANY REPAIR OR RECONSTRUCTION OF DAMAGED AREAS IN SURROUNDING PROPERTIES SHALL BE COMPLETED BY THE CONTRACTOR IMMEDIATELY.
ALL COSTS FOR REPAIRS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND NO EXTRA COMPENSATION SHALL BE ALLOWED.
DO NOT REMOVE TREES, ORNAMENTALS, LANDSCAPING, OR OTHER LANDSCAPE ITEMS WITHOUT PRIOR APPROVAL FROM OWNER.
17. THE CONTRACTOR SHALL MAINTAIN ACCESS TO PUBLIC, PRIVATE, AND COMMERCIAL PROPERTIES AT ALL TIMES DURING
CONSTRUCTION.
18. THE CONTRACTOR SHALL BE REQUIRED TO MAINTAIN AND REPAIR ALL ROADS DAMAGED DURING THE CONSTRUCTION PERIOD. IN SO DOING, THE CONTRACTOR SHALL BE REQUIRED TO PROVIDE BEFORE AND AFTER VIDEOS OF ROAD CONDITION FROM THE PROJECT SITE TO THE NEAREST STATE HIGHWAY. THE PUBLIC WORKS AND ROAD DEPARTMENTS OF THE RESPECTIVE CITIES AND COUNTIES SHALL BE CONTACTED BEFORE CONSTRUCTION BEGINS AND VIDEOS PROVIDED FOR THEIR REVIEW AND ACCEPTANCE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING AND PROVIDING ANY REPAIR BONDS REQUIRED BY THE RESPECTIVE ROAD
DEPARTMENTS. LOAD LIMITS ON EXISTING ROADS SHALL BE OBSERVED BY THE CONTRACTORS.
19. CONTRACTOR SHALL KEEP EXISTING CHANNELS AND DITCHES OPEN TO STORMWATER PASSAGE AT ALL TIMES DURING THE PROJECT.
20. CONTRACTOR SHALL DEWATER WORK AREA TO PROVIDE DRY EXCAVATION AT ALL TIMES. CONTRACTOR SHALL PROVIDE ALL PIPE, PUMPS, MATS, STONE, SAND, EXCAVATION, LABOR, ETC. TO ADEQUATELY DEWATER WORK AREA. IF CONTRACTOR ENCOUNTERS GROUNDWATER, GEOTEXTILE MUST BE LAID BELOW PIPE BEDDING MATERIALS. DEWATERING AND GEOTEXTILE COSTS SHALL BE
INCIDENTAL TO BID ITEMS PRICES.
21. ALL WASTE MATERIALS EXCAVATED FROM THE SITE SHALL BE REMOVED AND PROPERLY DISPOSED OFF-SITE BY THE CONTRACTOR.
MATERIALS SHALL BE STOCKPILED SEPARATELY AS TO USABLE (NON-ORGANIC) FILL STOCKPILES AND ORGANIC (MUCK) STOCKPILES.
CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL UNSUITABLE FILL MATERIALS FROM OR STOCKPILED ON THE SITE.
22. THE CONTRACTOR SHALL PREPARE AND FILE THE NOTICE OF INTENT FOR COVERAGE UNDER THE APPLICABLE NPDES GENERAL PERMIT TO DISCHARGE STORMWATER ASSOCIATED WITH THE CONSTRUCTION ACTIVITY AND PAY ALL REQUIRED FEES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FULL IMPLEMENTATION OF THE EROSION, SEDIMENTATION AND POLLUTION CONTROL PLAN, INCLUDING
RAINFALL MONITORING, INSPECTIONS AND ALL OTHER REQUIREMENTS OF THE PERMIT.
23. EROSION, SEDIMENTATION AND POLLUTION CONTROL MEASURES SHALL BE PROVIDED AND INSTALLED BY CONTRACTOR WITHIN THE LIMITS OF CLEARING AND CONSTRUCTION PRIOR TO OR CONCURRENT WITH THE COMMENCEMENT OF CONSTRUCTION. THESE MEASURES SHALL BE INSTALLED, PHASED, AND INSPECTED BY THE CONTRACTOR ON A REGULAR BASIS AND ARE TO BE MAINTAINED OR REPAIRED IMMEDIATELY. REFER TO EROSION, SEDIMENTATION, AND POLLUTION CONTROL PLAN FOR ADDITIONAL REQUIREMENTS.
SEE DRAWING NUMBERS C-8 THROUGH C-9 EROSION, SEDIMENTATION, AND POLLUTION CONTROL NOTES AND DETAILS.
24. ALL DISTURBED AREAS SHALL BE RE-VEGETATED IMMEDIATELY AFTER CONSTRUCTION IN A MANNER CONSISTENT WITH THE MANUAL FOR EROSION AND SEDIMENT CONTROL IN GEORGIA. ALL EROSION AND SEDIMENT CONTROLS SHALL BE INSTALLED PRIOR TO OR
CONCURRENT WITH THE START OF CONSTRUCTION.
25. THE CONTRACTOR SHALL STOCKPILE AND LATER SPREAD A MINIMUM OF 4 INCHES OF TOPSOIL IN AREAS TO BE LANDSCAPED OR
SEEDED.
26. THE CONTRACTOR SHALL MAINTAIN ONE COMPLETE HARD COPY OF THE APPROVED CONSTRUCTION PLANS AND THE APPROVED UTILITY ENCROACHMENT PERMIT ON-SITE AT ALL TIMES AND MAKE THEM READILY AVAILABLE FOR REFERENCE AND REVIEW BY THE OWNER, ENGINEER, AND OTHER AUTHORIZED REPRESENTATIVES. COORDINATION AND ACQUISITION OF THE UTILITY ENCROACHMENT PERMIT WILL BE PERFORMED BY THE ENGINEER; HOWEVER, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND
MAINTAINING A COPY OF THE APPROVED PERMIT ON-SITE THROUGHOUT CONSTRUCTION.
SEWER NOTES:
UTILITIES
1. THE MINIMUM HORIZONTAL AND VERTICAL SEPARATION BETWEEN WATER LINES, SEWER LINES, AND STORM DRAINS SHALL CONFORM
TO THE OWNER'S REQUIREMENTS.
2. ALL EXCAVATED TRENCHES SHALL BE COMPLETELY FILLED OR COVERED WITH PLATES AT THE END OF EACH WORKDAY.
3. CONTRACTOR SHALL DEWATER WORK AREA TO PROVIDE DRY EXCAVATION AT ALL TIMES. CONTRACTOR SHALL PROVIDE ALL PIPE, PUMPS, MATS, STONE, SAND, EXCAVATION, LABOR, ETC. TO ADEQUATELY DEWATER WORK AREA. IF CONTRACTOR ENCOUNTERS GROUNDWATER, GEOTEXTILE MUST BE LAID BELOW PIPE BEDDING MATERIALS. DEWATERING AND GEOTEXTILE COSTS SHALL BE
INCIDENTAL TO BID ITEMS PRICES UNLESS OTHERWISE SPECIFIED ON DRAWINGS.
4. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL ORGANIC MATTER, STUMPS, DELETERIOUS MATTER, CONCRETE PAVING, FOUNDATIONS, AND OTHER UNSUITABLE MATERIAL FROM WITHIN THE TRENCH AREAS.
5. STRUCTURAL FILL SHALL MEET COMPACTION REQUIREMENTS AND STANDARDS SET FORTH IN THE SPECIFICATIONS. MATERIALS EXCAVATED THAT ARE NOT SUITABLE FOR BACKFILL SHALL BE REMOVED FROM PROJECT AREA AT NO DIRECT COST TO THE OWNER.
BORROW MATERIALS MUST MEET REQUIREMENTS OF STRUCTURAL FILL AND SHALL BE OBTAINED FROM A SUITABLE SOURCE AND AT
THE EXPENSE OF THE CONTRACTOR.
6. ANY UTILITY CONFLICTS OR RELOCATIONS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CURRENT OWNER CONSTRUCTION
STANDARDS UNLESS OTHERWISE SHOWN ON DRAWINGS.
SEWER
1. CONTRACTOR SHALL RELOCATE ANY UTILITIES AT CONTRACTOR'S EXPENSE AS NEEDED TO INSTALL SEWER INFRASTRUCTURE UNLESS
OTHERWISE NOTED ON DRAWINGS. COORDINATE WITH UTILITY OWNERS.
2. MINIMUM DEPTH OF BURY ON GRAVITY SEWER AND FORCE MAIN SHALL BE 4 FEET UNLESS OTHERWISE NOTED. COVER DEPTHS LESS
THAN 4 FEET MUST BE APPROVED BY THE ENGINEER AND OWNER.
3. CONTRACTOR SHALL MAINTAIN 10' SPACING BETWEEN THE GRAVITY SEWER MAIN AND EXISTING WATER MAINS WHERE POSSIBLE.
WHERE 10' SPACING ISN'T POSSIBLE, SANITARY SEWER SHALL BE INSTALLED WITH 18" VERTICAL DISTANCE BETWEEN BOTTOM OF
WATER MAIN AND TOP OF GRAVITY SEWER.
4. A MINIMUM SEPARATION OF 20' OR TWO TIMES THE DEPTH OF THE GRAVITY SEWER MAIN, WHICHEVER IS GREATER, SHALL BE MAINTAINED FROM ALL BUILDINGS, FOUNDATIONS AND TOP OF BANK ON ALL PONDS. ANY DEVIATION FROM THE REQUIREMENT MUST BE
APPROVED IN WRITING BY THE OWNER.
5. CONTRACTOR SHALL CONDUCT MANHOLE/WETWELL TESTING, PIPE DEFLECTION TESTING AND AIR TESTING. ALL TESTING SHALL BE
DONE IN THE PRESENCE OF A REPRESENTATIVE OF THE OWNER.
6. TRENCH SAFETY WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. TRENCH SLOPES AND BENCHING SHALL MEET OSHA
REQUIREMENTS TO ENSURE A SAFE PROJECT.
PROJECT CLOSEOUT
1. FOLLOWING SUBSTANTIAL COMPLETION OF THE PROJECT AND PRIOR TO FINAL PAYMENT, A RECORD SURVEY SHALL BE PERFORMED OF THE PROJECT AND CAD FILE OF SURVEY SHALL BE PROVIDED TO ENGINEER FOR PREPARATION OF RECORD DRAWINGS. THE SURVEY SHALL BE PERFORMED BY A LAND SURVEYOR REGISTERED IN THE STATE OF GEORGIA ARRANGED, COORDINATED, AND PAID FOR BY THE CONTRACTOR. THE RECORD SURVEY SHALL SHOW SANITARY SEWER ALIGNMENT, MANHOLE LOCATIONS, PIPE SIZES, PIPE TYPES, INVERT ELEVATIONS, FENCE LAYOUT, SITE CONTOURS, BUILDING CORNERS, VAULT AND WETWELL CORNERS, GENERATOR CORNERS, TRANSFORMER LOCATION, WELL LOCATION, AND ALL OTHER UTILITIES LOCATED ON THE PROJECT SITE . A REDLINE MARKUP OF THE DRAWINGS SHALL BE PREPARED WITH ALL INFORMATION SHOWN AND DELIVERED TO THE ENGINEER IN ACCORDANCE WITH THE
GENERAL CONDITIONS.
PROJECT SCOPE:
THE PROJECT SCOPE INCLUDES REROUTING THE EXISTING GRAVITY SEWER TO BYPASS THE CURRENT LIFT STATION, ALLOWING ITS
DECOMMISSIONING (BY OTHERS). IN SUMMARY, THIS INVOLVES:
1. PROVIDING TEMPORARY BYPASS PUMPING TO MAINTAIN SERVICE DURING CONSTRUCTION;
2. PLUGGING DOWNSTREAM MANHOLES AND ABANDON EXISTING PIPE;
3. INSTALLING NEW GRAVITY SEWER PIPING AND MANHOLES ALONG THE REROUTED ALIGNMENT;
4. MODIFYING EXISTING CLEANOUT INVERTS;
5. PERFORMING A DIRECTIONAL BORE BENEATH THE EXISTING STEPS TO AVOID DISTURBANCE; AND
6. IMPLEMENTING EROSION CONTROL FOR DISTURBED AREAS.
OF
ISSUE SEQUENCE
NO. DATE DESCRIPTION
DRAWING NO.
SHEET:
C:
\U se rs\ ch els ea .fa llin \on ed riv e - G we s, Llc \D es kto p\0
.29 .1.
C ov ing ton In du str ial P s\_ pla n_ sh ee ts\
9_
CV
_c ov er _s he et.
dw g
/07 /15
:59
A M
By : C he lse a F all in
© Copyright GWES (all rights reserved)
CHECKED:
APPROVED:
DESIGNED:
PROJECT NO.:
DATE:
0 7/7/26 ISSUE FOR BID
C-1 1 9
GENERAL NOTES,
CONSTRUCTION NOTES, LEGEND,
AND ABBREVIATIONS
B.B.M.
C.H.F.
060.29.1.25
C.H.F.
JUNE 2026
GSWCC LEVEL II CERTIFICATION 97778
EXPIRATION DATE: 10-08-2027
SCALE: N/A
MONITORING WELL NOTES:
1. CONTRACTOR SHALL ENSURE THAT A 10' BUFFER IS MAINTAINED AT ALL TIMES AROUND ALL MONITORING
WELLS. SEE DETAIL AT RIGHT.
2. IF GROUNDWATER IS ENCOUNTERED AT ANY TIME DURING GROUND EXCAVATION, CONTRACTOR SHALL
IMMEDIATELY ENACT PROTOCOL BELOW:
2.1. CALL SHAMUS MULVIHILL, PLANT MANAGER AT RESRG AUTOMOTIVE AT (770) 743-6409.
2.2. CALL MATT TILLER, DIRECTOR OF REMEDIATION AT GEORGIA-PACIFIC AT (478) 461-4514.
2.3. EMAIL SHAMUS MULVIHILL, MATT TILLER, BRIAN YODER, BURKE MURPH, AND CHELSEA FALLIN.
TO: SHAMUS MULVIHILL SHAMUS.MULVIHILL@RESRGAUTOMOTIVE.COM
MATT TILLER MATT.TILLER@GAPAC.COM
CC: BRIAN YODER BYODER@CITYOFCOVINGTON.ORG
BURKE MURPH BURKE.MURPH@GWESLLC.COM
CHELSEA FALLIN CHELSEA.FALLIN@GWESLLC.COM
MONITORING WELL
10' BUFFER
WELL MONITORING BUFFER DETAIL
NOT TO SCALE
S
IN
DU
ST
RI
AL
B
OU
LE
VA
RD
LI
FT
ST
AT
IO
N:
S
EW
ER
E
XT
EN
SI
ON
FO
R
TH
E
CI
TY
O F
CO
VI
NG
TO
N
OF
ISSUE SEQUENCE
NO. DATE DESCRIPTION
DRAWING NO.
SHEET:
C:
\U se rs\ ch els ea .fa llin \on ed riv e - G we s, Llc \D es kto p\0
.29 .1.
C ov ing ton In du str ial P s\_ pla n_ sh ee ts\
9_
CV
_c ov er _s he et.
dw g
/07 /15
:59
A M
By : C he lse a F all in
© Copyright GWES (all rights reserved)
CHECKED:
APPROVED:
DESIGNED:
PROJECT NO.:
DATE:
0 7/7/26 ISSUE FOR BID
KEY MAP
C-2
C-2GENERAL LOCATION MAP
IN
DU
ST
RI
AL
B
LV
D
I-20
ALC
OVY RD
PROJECT
AREA
I-20
GA
-14
HA
ZE
LB
RA
ND
R
D
NE
HWY 278 NE
HWY 278 NE
I-20
ALC
OVY RD
INDUSTRIAL BLVD
INDUSTRIAL DR NE
B.B.M.
C.H.F.
060.29.1.25
C.H.F.
JUNE 2026
GSWCC LEVEL II CERTIFICATION 97778
EXPIRATION DATE: 10-08-2027
0 500' 1000'250'
SCALE:
IN
DU
ST
RI
AL
B
OU
LE
VA
RD
LI
FT
ST
AT
IO
N:
S
EW
ER
E
XT
EN
SI
ON
FO
R
TH
E
CI
TY
O F
CO
VI
NG
TO
N
WATERFORD RD NE
SETTLERS GROVE RD NE
INDUSTRIAL BLVD (100' R/W)
HA
ZE
LB
RA
ND
R
D
NE
(6 0'
R/ W
WATERFORD RD (50' R/W)
HA
ZE
LB
RA
ND
R
D
NE
(6 0'
R/ W
SETTLERS GROVE RD
(50 ' R
/W
N/F
COVINGTON MOULDING CO
C/O GUARDIAN AUTOMOTIVE
N/F
RONGRONG DENG
N/F
RONGRONG DENG
N/F
JASON GRINDLE
N/F
LARRY & VALERIE DANIEL
N/F
ANDRE LUTON
N/F
WILLIE JEAN BELL
N/F
AMBER DAWN WALTOWER
N/F
RESICAP GEORGIA OWNER LLC
N/F
CONYERS SQUARE LLP
N/F
NEWTON HOSPITALITY LLC
N/F
JST RENTAL PROPERTIES II LLC
N/F
DRW ENTERPRISES LLCN/F
TS CENTRAL PROPERTIES LLC
SANITARY SEWER
MH TOP=*
*UNDER CONSTRUCTION
LIMITS OF CONSTRUCTION (0.76 AC)
CO
OF
ISSUE SEQUENCE
NO. DATE DESCRIPTION
DRAWING NO.
SHEET:
C:
\U se rs\ ch els ea .fa llin \on ed riv e - G we s, Llc \D es kto p\0
.29 .1.
C ov ing ton In du str ial P s\_ pla n_ sh ee ts\
9_
SS
_s an ita ry_ se we r_ pla n_ pr ofi le.
dw g
/07 /15
:00
A M
By : C he lse a F all in
© Copyright GWES (all rights reserved)
CHECKED:
APPROVED:
DESIGNED:
PROJECT NO.:
DATE:
0 7/7/26 ISSUE FOR BID
EXISTING CONDITION AND
DEMOLITION
C-3
B.B.M.
C.H.F.
060.29.1.25
C.H.F.
JUNE 2026
GSWCC LEVEL II CERTIFICATION 97778
EXPIRATION DATE: 10-08-2027
IN
DU
ST
RI
AL
B
OU
LE
VA
RD
LI
FT
ST
AT
IO
N:
S
EW
ER
E
XT
EN
SI
ON
SCALE:
0 40' 80'
SAW CUT ALONG EDGE OF ASPHALT
DEMO AND REMOVE ±15 SY OF ASPHALT
SAW CUT ALONG EDGE OF ASPHALT
DEMO AND REMOVE ±30 SY OF ASPHALT
MONITORING WELL NOTES:
1. CONTRACTOR SHALL ENSURE THAT A 10' BUFFER IS MAINTAINED AT ALL TIMES AROUND ALL
MONITORING WELLS. SEE DETAIL AT RIGHT.
2. IF GROUNDWATER IS ENCOUNTERED AT ANY TIME DURING GROUND EXCAVATION,
CONTRACTOR SHALL IMMEDIATELY ENACT PROTOCOL BELOW:
2.1. CALL SHAMUS MULVIHILL, PLANT MANAGER AT RESRG AUTOMOTIVE AT (770) 743-6409.
2.2. CALL MATT TILLER, DIRECTOR OF REMEDIATION AT GEORGIA-PACIFIC AT (478) 461-4514.
2.3. EMAIL SHAMUS MULVIHILL, MATT TILLER, BRIAN YODER, BURKE MURPH, AND CHELSEA
FALLIN.
TO: SHAMUS MULVIHILL SHAMUS.MULVIHILL@RESRGAUTOMOTIVE.COM
MATT TILLER MATT.TILLER@GAPAC.COM
CC: BRIAN YODER BYODER@CITYOFCOVINGTON.ORG
BURKE MURPH BURKE.MURPH@GWESLLC.COM
CHELSEA FALLIN CHELSEA.FALLIN@GWESLLC.COM
LOCATION OF EXISTING MANHOLE UNKNOWN.
CITY PURPOSEFULLY COVERED BECAUSE
CONTINUALLY DRIVEN OVER BY TRACTOR
TRAILERS SUBSEQUENTLY CAUSING DAMAGE.
FO
R
TH
E
CI
TY
O F
CO
VI
NG
CO
CO
INDUSTRIAL BLVD (100' R/W)
HA
ZE
LB
RA
ND
R
D
NE
(6 0'
R/ W
WATERFORD RD (50' R/W)
HA
ZE
LB
RA
ND
R
D
NE
(6 0'
R/ W
SETTLERS GROVE RD
(50 ' R
/W
PR. SSMH-203
STA:16+63.86
N 1314459.17 E 2398195.26
PR. SSMH-202
STA:14+02.39 & 30+00.00
N 1314232.20 E 2398065.44
EX. SSMH-02
STA:10+00.00
N 1313943.15 E 2398061.52
EX. SSMH-08
STA:34+53.24
N 1314409.77 E 2397701.40
6'' EX. CO-03
STA:33+84.15
N 1314353.60 E 2397741.64
6'' EX. CO-02
STA:33+49.69
N 1314326.90 E 2397763.42
CO
5'' EX. CO-04
STA:34+75.60
N 1314390.24 E 2397690.52
N/F
COVINGTON MOULDING CO
C/O GUARDIAN AUTOMOTIVE
N/F
RONGRONG DENG
N/F
RONGRONG DENG
N/F
JASON GRINDLE
N/F
LARRY & VALERIE DANIEL
N/F
ANDRE LUTON
N/F
WILLIE JEAN BELL
N/F
AMBER DAWN WALTOWER
N/F
RESICAP GEORGIA OWNER LLC
N/F
CONYERS SQUARE LLP
N/F
NEWTON HOSPITALITY LLC
N/F
JST RENTAL PROPERTIES II LLC
N/F
DRW ENTERPRISES LLCN/F
TS CENTRAL PROPERTIES LLC
EX. SSMH-07
EX. SSMH-06
EX. SSMH-04
STA:55+25.03
N 1314457.05 E 2398470.88
EX. SSMH-01
EX. SSMH-05
STA:50+00.00
N 1314516.11 E 2397949.18
EX. SSMH-03
STA:52+42.40 & 16+98.93
N 1314488.68 E 2398190.03
LIMITS OF CONSTRUCTION (0.76 AC)
PR. SSMH-201
STA:11+40.42
N 1314004.80 E 2397935.36
PR. BEND-201 (8'' DI 45)
STA:30+66.69
N 1314284.30 E 2398023.80
CO
OF
ISSUE SEQUENCE
NO. DATE DESCRIPTION
DRAWING NO.
SHEET:
C:
\U se rs\ ch els ea .fa llin \on ed riv e - G we s, Llc \D es kto p\0
.29 .1.
C ov ing ton In du str ial P s\_ pla n_ sh ee ts\
9_
SS
_s an ita ry_ se we r_ pla n_ pr ofi le.
dw g
/07 /15
:00
A M
By : C he lse a F all in
© Copyright GWES (all rights reserved)
CHECKED:
APPROVED:
DESIGNED:
PROJECT NO.:
DATE:
0 7/7/26 ISSUE FOR BID
SITE PLAN
C-4
B.B.M.
C.H.F.
060.29.1.25
C.H.F.
JUNE 2026
GSWCC LEVEL II CERTIFICATION 97778
EXPIRATION DATE: 10-08-2027
PLUG EXISTING MANHOLE
PLUG AND ABANDON
8" SANITARY SEWER FROM
EX. SSMH-05 TO EX. SSMH-06
PLUG EXISTING MANHOLE
ABANDON 8" SANITARY
SEWER UNDER ROAD FROM
EX. SSMH-06 TO EX. SSMH-07
PLUG EXISTING MANHOLE
PLUG AND ABANDON 8"
SANITARY SEWER FROM EX.
SSMH-03 TO EX. SSMH-05
PR. BEND-202 (8" DI 45)
STA:32+83.57
N 1314307.46 E 2397819.93
PR. BEND-204 (8" DI 45)
STA:33+18.45
N 1314294.44 E 2397787.93
PR. BEND-203 (8" DI 22.5 AND WYE)
STA: 33+06.60
N 1314293.03 E 2397801.98
PR. BEND-204 (8" DI 45)
STA:33+18.45
N 1314294.44 E 2397787.93
±15 LF 8" DUCTILE IRON
DEMO AND REMOVE OR
ABANDON EXISTING SEWER
PIPE IN PLACE AS NEEDED
PR. BEND-205 (8" DI 45)
N 1314278.14 E 2397800.23
PR. BEND-206 (6"X8" DI REDUCER)
N 1314270.15 E 2397806.25
CONNECT EXISTING PIPE FROM
EX. CO-01 TO PR. BEND-206
INVERT UNKNOWN
INSTALL ±305 LF SINGLE
ROW TYPE "S" SILT FENCE
INSET - SITE PLAN
SCALE:
CLASS A ASPHALT
PATCH ±15 SY
DEMOLITION OF EXISTING
LIFT STATION BY OTHERS
ALL DISTURBED AREAS
Ds1 Ds2 Ds3
Du Tp
ALL DISTURBED AREAS
Ds1 Ds2 Ds3
Du Tp
ALL DISTURBED AREAS
Ds1 Ds2 Ds3
Du Tp
ALL DISTURBED AREAS
Ds1 Ds2 Ds3
Du Tp
Sd1-S
ADJUST INVERT OF EXISTING CLEAN OUTS TO MATCH
PROFILE VIEW (TYP 2)
CONNECT TO 8" HDPE WITH 8"X4" ROMAC SADDLE STYLE BP
PLUG INVERT TORWARDS
LIFT STATION
0 40' 80'
SCALE:
CLASS A ASPHALT
PATCH ±30 SY
±145 LF 8" DIPS HDPE DR 11
DIRECTIONAL BORE FROM
PR. BEND-204 TO EX. SSMH-08
8" PVC SDR 26
8" PVC SDR 26
8" DUCTILE IRON
APPROX. STA 31+46
8" DUCTILE IRON SLEEVE
8" DUCTILE IRON
SEE INSET AT LEFT
0 10' 20'
±15 LF 8" DUCTILE IRON
±10 LF 8" DUCTILE IRON
MONITORING WELL NOTES:
1. CONTRACTOR SHALL ENSURE THAT A 10' BUFFER IS MAINTAINED AT ALL TIMES AROUND ALL
MONITORING WELLS. SEE DETAIL AT RIGHT.
2. IF GROUNDWATER IS ENCOUNTERED AT ANY TIME DURING GROUND EXCAVATION,
CONTRACTOR SHALL IMMEDIATELY ENACT PROTOCOL BELOW:
2.1. CALL SHAMUS MULVIHILL, PLANT MANAGER AT RESRG AUTOMOTIVE AT (770) 743-6409.
2.2. CALL MATT TILLER, DIRECTOR OF REMEDIATION AT GEORGIA-PACIFIC AT (478) 461-4514.
2.3. EMAIL SHAMUS MULVIHILL, MATT TILLER, BRIAN YODER, BURKE MURPH, AND CHELSEA
FALLIN.
TO: SHAMUS MULVIHILL SHAMUS.MULVIHILL@RESRGAUTOMOTIVE.COM
MATT TILLER MATT.TILLER@GAPAC.COM
CC: BRIAN YODER BYODER@CITYOFCOVINGTON.ORG
BURKE MURPH BURKE.MURPH@GWESLLC.COM
CHELSEA FALLIN CHELSEA.FALLIN@GWESLLC.COM
NOTES:
1. ALL MANHOLES SHALL HAVE WATERTIGHT MANHOLE FRAME AND COVER.
2. PIPE LENGTHS SHOWN IN PROFILE ARE FROM CENTER OF MANHOLE TO CENTER OF MANHOLE.
3. CONTRACTOR SHALL COORDINATE ALL WORK WITH CITY OF COVINGTON TO ENSURE NO
INTERRUPTION IN SERVICE.
4. CONTRACTOR SHALL CLEAR AND GRUB AS NECESSARY WITHIN THE LIMITS OF CONSTRUCTION.
5. CONTRACTOR SHALL PROVIDE A BYPASS PUMPING PLAN FOR REVIEW BY ENGINEER AND OWNER
AT LEAST 10 DAYS PRIOR TO BYPASS PUMPING OPERATIONS.
6. WHEN PREVIOUSLY IN-SERVICE SANITARY SEWER PIPE IS ENCOUNTERED DURING INVERT
ADJUSTMENTS, THE CONTRACTOR SHALL REMOVE IT WHILE WORKING IN THE AREA AND
PROPERLY ABANDON ANY REMAINING CONNECTIONS.
7. INLET PIPES AT THE CLEANOUT LOCATIONS SHALL ALSO BE CONNECTED TO THE CLEANOUT
ASSEMBLY AS SHOWN ON THE PLANS.
8. CONTRACTOR SHALL PROTECT EXISTING SITE FEATURES INCLUDING BUT NOT LIMITED TO
ASPHALT, CURB AND GUTTER, AND DRIVEWAYS. CONTRACTOR IS RESPONSIBLE FOR DAMAGES
AT THEIR OWN EXPENSE.
±23 LF 8" DUCTILE IRON
FUSE 8" DI 45 TO END
OF DIPS HDPE DR 11
LIMITS OF CONSTRUCTION (0.76 AC)
INSTALL HAY BALE
CHECK DAMS (TYP. 10)
Cd-Hb
CONTRACTOR SHALL FIELD VERIFY
EXISTING LATERAL INVERT FROM 10155
INDUSTRIAL BLVD AND REFORM SSMH
INVERT WITH GROUT AS NEEDED
LOCATE EXISTING SSMH
AND ADJUST TO GRADE
PLUG WEST INVERT
8" PVC SDR 26
8" PVC SDR 26
8" PVC SDR 26
CONCRETE BARRIER WALL
HAZELBRAND RD NE CLOSED TO THRU TRAFFIC WITH
THE EXCEPTION OF TRAFFIC TO/FROM RONGRONG DENG
ROADROAD
CLOSED
ROADROAD
CLOSED
HAZELBRAND RD NE /
WATERFORD RD
INTERSECTION CLOSED
FOR CONSTRUCTION
INLET SEDIMENT TRAP (TYP 2)
Sd2-P
IN
DU
ST
RI
AL
B
OU
LE
VA
RD
LI
FT
ST
AT
IO
N:
S
EW
ER
E
XT
EN
SI
ON
FO
R
TH
E
CI
TY
O F
CO
VI
NG
PR
. S
SM
H-
ST
A:
4+
" D
IA
M
AN
HO
LE
RI
M
: 7
.4
IN
V
IN
: 7
.5
(N
W
IN
V
IN
: 7
.4
(N
E)
IN
V O
UT
: 7
.1
(S
W
PR
. S
SM
H-
ST
A:
1+
" D
IA
M
AN
HO
LE
RI
M
: 7
.1
IN
V
IN
: 7
.1
(N
E)
IN
V O
UT
: 7
.0
(S
E)
EX
. S
SM
H-
ST
A:
0+
" D
IA
M
AN
HO
LE
RI
M : 7
.3
IN
V
IN
: 7
.5
(N W
IN
V
IN
: 7
.9
(N
IN
V
IN
: 7
.8
(S
W
IN
V
O
UT
: 7
.4
(S E)
PR
. S
SM
H-
ST
A:
4+
0+
" D
IA
M
AN
HO
LE
RI
M
: 7
.4
IN
V
IN
: 7
.5
(N
W
IN
V
IN
: 7
.4
(N
E)
IN
V O
UT
: 7
.1
(S
W
GRAVITY SEWER PROFILE - 30+00 TO 35+20
SCALE: 1" = 40' (H) / 1" = 4' (V)
GRAVITY SEWER PROFILE - 10+00 TO 17+60
SCALE: 1" = 40' (H) / 1" = 4' (V)
6'' E
X.
C
O -0
ST
A:
3+
6" P
VC
C
LE
AN
O
UT
RI
M
: 7
.8
IN
V
IN
: 7
.0
(N
W
IN
V
O
UT
: 7
.0
(S E)
6'' E
X.
C
O -0
ST
A:
3+
6" P
VC
C
LE
AN
O
UT
RI
M
: 7
.1
IN
V
IN
: 7
.3
(N
W
IN
V
O
UT
: 7
.3
(S E)
5'' E
X.
C
O -0
ST
A:
4+
5" P
VC
C
LE
AN
O
UT
RI
M
: 7
.3
IN
V
O
UT
: 7
.7
(N E)
EX
. S
SM
H-
ST
A:
4+
" D
IA
M
AN
HO
LE
RI
M : 7
.6
IN
V
IN
: 7
.0
(S W
IN
V
IN
: 7
.0
(S W
IN
V
IN
: 7
.0
(S E)
IN
V
O
UT
: 7
.8
(S E)
EX. CMP UNDER DRIVEWAY
DIA AND INVERTS UNKNOWN
ASPHALT DRIVEWAY TO
EMPLOYEE PARKING LOT
HA
ZE
LB
RA
ND
(6
0' R/
W
W
AT
ER
FO
RD
R
D (5
0' R/
W
140 LF 8" DUCTILE IRON @ 0.40% MINIMUM
261 LF 8" PVC SDR26 @ 0.40% MIN
262 LF 8" PVC SDR26 @ 0.40% MINIMUM
80 LF 8'' PVC SDR26 @ 0.80%
23 LF 8" DUCTILE IRON @ 11.38%
±145 LF 8-INCH DIPS HDPE
DR 11 DIRECTIONAL BORE
FROM PR. BEND-204 TO
EX. SSMH-08
CONCRETE STAIRCASE
TO EMPLOYEE PARKING
EXISTING GRADE
EXISTING GRADE
STA: 32+74 EX. 36" CMP
INVERT UNKNOWNSTA: 31+51 EX. 18" HDPE
INVERT UNKNOWN
APPROX. STA 31+46
8" DUCTILE IRON SLEEVE
125 LF 8'' DUCTILE IRON @ 0.80%
SE
E
C
LE
AN
O
U T
TI
E
IN
D
ET
AI
L
67 LF 8" PVC SDR26 @ 0.80%
PR
. B
EN
D-
(8 '' D
I 4 5)
ST
A:
2+
8"
D I F
IT
TI
NG
RI
M : 7
.8
IN
V
IN
: 7
.7
(S W
IN
V O
UT
: 7
.7
(E
PR
. B
EN
D-
(8 '' D
I 4 5)
ST
A:
0+
8"
D I F
IT
TI
NG
RI
M : 7
.8
IN
V
IN
: 7
.0
(W
IN
V
O
UT
: 7
.0
(S E)
PR
. B
EN
D-
(8 '' D
I 2 2.
AN
D W
YE
ST
A:
2+
8"
D I F
IT
TI
NG
W
YE
RI
M : 7
.5
IN
V
IN
: 7
.4
(W
IN
V
O
UT
: 7
.4
(N E)
PR
. B
EN
D-
(8 '' D
I 4 5)
ST
A:
3+
8"
D I F
IT
TI
NG
RI
M : 7
.9
IN
V
IN
: 7
.6
(N W
IN
V O
UT
: 7
.6
(E
14 LF 8" DUCTILE IRON @ 1.00%
22 LF 6" EXISTING PVC @ 11.81%
30 LF 8" PVC SDR26 @ 0.40% MIN
EX
. S
SM
H-
ST
A:
2+
" D
IA
M
AN
HO
LE
RI
M : 7
.1
PR
. S
SM
H-
ST
A:
6+
" D
IA
D O
G
HO
US
E
M
AN
HO
LE
RI
M
: 7
.2
IN
V
IN
: U
NK
NO
W N
(E
IN
V
IN
: 7
.3
(N
IN
V O
UT
: 7
.9
(S
W
EXISTING LATERAL INVERT FROM 10155 INDUSTRIAL BLVD
SHALL BE FIELD VERIFIED BY CONTRACTOR. CONTRACTOR
SHALL REFORM SSMH INVERT WITH GROUT AS NEEDED.
HA
ZE
LB
RA
ND
(6
0' R/
W
OF
ISSUE SEQUENCE
NO. DATE DESCRIPTION
DRAWING NO.
SHEET:
C:
\U se rs\ ch els ea .fa llin \on ed riv e - G we s, Llc \D es kto p\0
.29 .1.
C ov ing ton In du str ial P s\_ pla n_ sh ee ts\
9_
SS
_s an ita ry_ se we r_ pla n_ pr ofi le.
dw g
/07 /15
:00
A M
By : C he lse a F all in
© Copyright GWES (all rights reserved)
CHECKED:
APPROVED:
DESIGNED:
PROJECT NO.:
DATE:
0 7/7/26 ISSUE FOR BID
PROFILES
C-5
B.B.M.
C.H.F.
060.29.1.25
C.H.F.
JUNE 2026
GSWCC LEVEL II CERTIFICATION 97778
EXPIRATION DATE: 10-08-2027
0 40' 80'
0 4' 8'
H:
V:
SCALE:
IN
DU
ST
RI
AL
B
OU
LE
VA
RD
LI
FT
ST
AT
IO
N:
S
EW
ER
E
XT
EN
SI
ON
FO
R
TH
E
CI
TY
O F
CO
VI
NG
UNABLE TO LOCATE MANHOLE.
CONTRACTOR TO VERIFY INVERTS
UPON LOCATING MANHOLE AND
ADJUST INVERTS ACCORDINGLY
EX
. S
SM
H-
ST
A:
5+
" D
IA
M
AN
HO
LE
RI
M : 7
.5
IN
V
IN
: 7
.5
(E
IN
V
O
UT
: 7
.2
(W
EX
. S
SM
H-
ST
A:
2+
8" PVC
30 LF 8" PVC SDR26 @ MIN 0.5%
PR
. S
SM
H-
ST
A:
6+
" D
IA
D O
G
HO
US
E
M
AN
HO
LE
RI
M
: 7
.2
IN
V
IN
: U
NK
NO
W N
(E
IN
V
IN
: 7
.3
(N
IN
V O
UT
: 7
.9
(S
W
8" PVC
EX
. S
SM
H-
ST
A:
0+
" D
IA
M
AN
HO
LE
RI
M : 7
.4
IN
V
IN
: 7
.6
(E
IN
V
O
UT
: 7
.2
(W
EXISTING LATERAL FROM
10155 INDUSTRIAL BLVD
PLUG AND ABANDON 8"
SANITARY SEWER FROM EX.
SSMH-03 TO EX. SSMH-05
CONTRACTOR SHALL FIELD VERIFY
LATERAL INVERT AND REFORM SSMH
INVERT WITH GROUT AS NEEDED
GRAVITY SEWER PROFILE - 50+00 TO 55+60
SCALE: 1" = 40' (H) / 1" = 4' (V)
EXISTING GRADE
OF
ISSUE SEQUENCE
NO. DATE DESCRIPTION
DRAWING NO.
SHEET:
C:
\U se rs\ ch els ea .fa llin \on ed riv e - G we s, Llc \D es kto p\0
.29 .1.
C ov ing ton In du str ial P s\_ pla n_ sh ee ts\
9_
SS
_s an ita ry_ se we r_ pla n_ pr ofi le.
dw g
/07 /15
:00
A M
By : C he lse a F all in
© Copyright GWES (all rights reserved)
CHECKED:
APPROVED:
DESIGNED:
PROJECT NO.:
DATE:
0 7/7/26 ISSUE FOR BID
PROFILES
C-6
B.B.M.
C.H.F.
060.29.1.25
C.H.F.
JUNE 2026
GSWCC LEVEL II CERTIFICATION 97778
EXPIRATION DATE: 10-08-2027
0 40' 80'
0 4' 8'
H:
V:
SCALE:
IN
DU
ST
RI
AL
B
OU
LE
VA
RD
LI
FT
ST
AT
IO
N:
S
EW
ER
E
XT
EN
SI
ON
FO
R
TH
E
CI
TY
O F
CO
VI
NG
NO. DATE DESCRIPTION
DRAWING NO.
SHEET:
C:
\U se rs\ ch els ea .fa llin \on ed riv e - G we s, Llc \D es kto p\0
.29 .1.
C ov ing ton In du str ial P s\_ pla n_ sh ee ts\
9_
CV
_c ov er _s he et.
dw g
/07 /15
:00
A M
By : C he lse a F all in
© Copyright GWES (all rights reserved)
CHECKED:
APPROVED:
DESIGNED:
PROJECT NO.:
DATE:
0 7/7/26 ISSUE FOR BID
CONSTRUCTION DETAILS
C-7 7 9
B.B.M.
C.H.F.
060.29.1.25
C.H.F.
JUNE 2026
GSWCC LEVEL II CERTIFICATION 97778
EXPIRATION DATE: 10-08-2027
L TRENCHC
UNDISTURBED
EARTH
BACKFILL COMPACTED TO
95% STANDARD PROCTOR
IN 6" LIFTS
8" 4,000 PSI
CONCRETE
EXISTING ASPHALT
VERTICAL SAW CUT
EACH SIDE OF TRENCH
12" CUTBACK
EACH SIDE
1.5" HOT MIX ASPHALT, 9.5mm
SUPERPAVE BASE, TYPE 2
10" GRADED AGGREGATE BASE
COMPACTED TO 95% MODIFIED
PROCTOR (ASTM D1557)
EXISTING BASE
OR SUBGRADE
ASPHALT PATCH
NOT TO SCALE
O.D. + 18" MAX. EXISTING
GRADE
48" MIN.
6" MIN.
O.D.
6" MIN.
HAND PLACED EARTH
BACKFILL PLACED IN 6"
LAYERS AND TAMPED
#57 STONE BEDDING FOR PVC
NOTE:
PVC SHALL BE CONNECTED TO MANHOLES BY RUBBER BOOT IN CORED OR
PRECAST HOLE OF THE PROPER DIAMETER.
BACKFILL REQUIREMENTS:
1. OUTSIDE OF EXISTING OR PROPOSED PAVING COMPACTED TO 95%
STANDARD PROCTOR.
2. UNDER EXISTING OR PROPOSED PAVING COMPACTED TO 100% STANDARD
PROCTOR
PVC GRAVITY SEWER BEDDING
NOT TO SCALE
O.D. + 18" MAX. EXISTING
GRADE
12" MIN.
4" MIN. OR O.D. X 0.125
HAND PLACED EARTH
BACKFILL PLACED IN 6"
LAYERS AND TAMPED
SELECT EARTH BACKFILL
NOTE:
DIP SHALL BE CONNECTED TO MANHOLES BY RUBBER BOOT IN CORED OR
PRECAST HOLE OF THE PROPER DIAMETER.
BACKFILL REQUIREMENTS:
1. OUTSIDE OF EXISTING OR PROPOSED PAVING COMPACTED TO 95%
STANDARD PROCTOR.
2. UNDER EXISTING OR PROPOSED PAVING COMPACTED TO 100% STANDARD
PROCTOR
DUCTILE IRON GRAVITY SEWER BEDDING
NOT TO SCALE
O.D.
GRANULAR FILL
(PIPE BEDDING)
5" MIN.
SEWER PIPE
PIPE CLAMP
RUBBER BOOT
WATERTIGHT
SEAL
NON-SHRINK
GROUT
MANHOLE
STRUCTURE
NOTE:
PVC AND D.I.P. SHALL BE CONNECTED TO MANHOLES BY
RUBBER BOOT IN CORED OR PRECAST HOLE OF THE
PROPER DIAMETER
DETAIL - RUBBER BOOT
SCALE: N.T.S.
SCALE: N/A
NOTE:
1. CONTRACTOR SHALL MILL EACH END OF ASPHALT PATCH.
2. TRENCH SHALL BE FILLED WITH ROCK OR COVERED WITH STEEL PLATE AT
THE END OF EACH WORK DAY.
IN
DU
ST
RI
AL
B
OU
LE
VA
RD
LI
FT
ST
AT
IO
N:
S
EW
ER
E
XT
EN
SI
ON
FO
R
TH
E
CI
TY
O F
CO
VI
NG
NO. DATE DESCRIPTION
DRAWING NO.
SHEET:
C:
\U se rs\ ch els ea .fa llin \on ed riv e - G we s, Llc \D es kto p\0
.29 .1.
C ov ing ton In du str ial P s\_ pla n_ sh ee ts\
9_
CV
_c ov er _s he et.
dw g
/07 /15
:00
A M
By : C he lse a F all in
© Copyright GWES (all rights reserved)
CHECKED:
APPROVED:
DESIGNED:
PROJECT NO.:
DATE:
0 7/7/26 ISSUE FOR BID
ESPCP DETAILS
C-8 8 9
B.B.M.
C.H.F.
060.29.1.25
C.H.F.
JUNE 2026
GSWCC LEVEL II CERTIFICATION 97778
EXPIRATION DATE: 10-08-2027
Sd1-S DETAIL - SEDIMENT BARRIER SILT FENCE
SIDE VIEW
FRONT VIEW
GROUND
SURFACE
FABRIC
WOOD POST (SEE NOTE 1)
(WITH MULCHING ONLY)
DISTURBED AREA STABILIZATIONDs1
RATETEMPORARY SEEDMONTH RATETEMPORARY SEEDMONTH
Ds2 (WITH TEMPORARY SEEDING)
DISTURBED AREA STABILIZATION
DUST CONTROL ON DISTURBED AREASDu
TOPSOILINGTp
STRUCTURAL PRACTICES
UNIFORM CODE
CODE PRACTICE DETAIL DESCRIPTIONMAP
SYMBOL
Sd1
Ds3Ds3
TpTp
VEGETATIVE PRACTICES
CODE PRACTICE DETAIL DESCRIPTIONMAP
SYMBOL
Ds1Ds1
Ds2Ds2
DuDu
PLAN SECTION A-A
SECTION B-B
NOTES:
1. BALES SHOULD BE BOUND WITH WIRE OR NYLON STRING AND SHOULD BE PLACED IN ROWS
WITH BALE ENDS TIGHTLY ABUTTING THE ADJACENT BALES.
2. REMOVE #4 REBAR AFTER STRAW BALES ARE NO LONGER IN PLACE.
3. POINT C OF SECTION B-B SHOULD ALWAYS BE HIGHER THAN POINT D.
DETAIL - STRAW BALE CHECK DAM
N.T.S.
Cd-Hb
SCALE: N/A
Cd
Sd2
IN
DU
ST
RI
AL
B
OU
LE
VA
RD
LI
FT
ST
AT
IO
N:
S
EW
ER
E
XT
EN
SI
ON
FO
R
TH
E
CI
TY
O F
CO
VI
NG
NO. DATE DESCRIPTION
DRAWING NO.
SHEET:
C:
\U se rs\ ch els ea .fa llin \on ed riv e - G we s, Llc \D es kto p\0
.29 .1.
C ov ing ton In du str ial P s\_ pla n_ sh ee ts\
9_
CV
_c ov er _s he et.
dw g
/07 /15
:00
A M
By : C he lse a F all in
© Copyright GWES (all rights reserved)
CHECKED:
APPROVED:
DESIGNED:
PROJECT NO.:
DATE:
0 7/7/26 ISSUE FOR BID
ESPCP DETAILS
C-9 9 9
B.B.M.
C.H.F.
060.29.1.25
C.H.F.
JUNE 2026
GSWCC LEVEL II CERTIFICATION 97778
EXPIRATION DATE: 10-08-2027
Ds3
RATEPERMANENT SEEDMONTH
(WITH PERMANENT VEGETATION)
DISTURBED AREA STABILIZATION
SCALE: N/A
4"
CURB INLET FILTER "PIGS IN BLANKET"
4"
PLAN
Sd2-P DETAIL - INLET SEDIMENT TRAP AT CURB
SECTION B-B
IN
DU
ST
RI
AL
B
OU
LE
VA
RD
LI
FT
ST
AT
IO
N:
S
EW
ER
E
XT
EN
SI
ON
FO
R
TH
E
CI
TY
O F
CO
VI
NG
| Sheets and Views |
| CV-1 COVER |
| C-1 GENERAL NOTES, CONSTRUCTION NOTES, LEGEND, AND ABBREVIATIONS |
| C-2 KEY MAP |
| C-3 EXISTING CONDITION AND DEMOLITION |
| C-4 SITE PLAN |
| C-5 PROFILES |
| C-6 PROFILES |
| C-7 CONSTRUCTION DETAILS |
| C-8 ESPCP DETAILS |
| C-9 ESPCP DETAILS |
File details come from the government source that posted it. Updated .