II.E.ii. N6660426Q0045 - SOW.pdf
PDF 527 KB Posted
- Attached to
- Notice of Sole Source to Thermotron Industries for Environmental Chamber Evaluation and Repair
- Solicitation number
- N6660426Q0045
About this file
This Statement of Work (SOW) details repair services for Thermotron environmental test chambers at the Naval Undersea Warfare Center Division in Newport, Rhode Island. The contract covers repair and maintenance of seven specific Thermotron environmental chambers with serial numbers 50853, 49825, 49826, 49827, 49828, 49234, 51158, and 53312, which are used for Virginia Class Non-Propulsion Electronic Systems testing. The chambers can produce test environments from -73C to 175C with humidity ranges of 20% to 98%, and require specialized maintenance by factory-authorized technicians.
Key requirements include providing written repair estimates for government approval, performing emergency repairs with crucial response times, and delivering temperature/humidity calibration certificates and preventative maintenance reports upon repair completion. The contractor must adhere to specific security protocols, including compliance with National Industrial Security Program Operating Manual (NISPOM) guidelines, protecting controlled unclassified information, and implementing an Operations Security (OPSEC) program. The contract is funded through NUWCDIVNPT Overhead/Service Cost Center, with repairs to be conducted on-site at the Naval Undersea Warfare Center Division in Newport, Rhode Island.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| II.E. RFQ N6660426Q0045.pdf | ||
| II.E.i. Exhibit A CDRLs_Redacted.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
v4.6_OCTOBER2025
STATEMENT OF WORK (SOW)/PERFORMANCE WORK STATEMENT (PWS)
Environmental Thermotron Chambers Repair Services
N66604-26-SIMACQ-NPT-70-0034
1.0 Background
The Naval Undersea Warfare Center Division, Newport (NUWCDIVNPT) is the Navy’s principal Environmental Testing facility for Virginia Class Non-Propulsion Electronic Systems. The Survivability Assessment Team, Code 7012, performs over ten thousand (10,000) hours per year of environmental qualification testing. Part of this testing utilizes Thermotron Environmental Temperature and Humidity Chambers capable of producing test environments from -73C to 175C with humidity ranges of 20% to 98%. These chambers require specialized maintenance by factory authorized technicians to keep them operational and preforming.
1.1 Places of Performance
Naval Undersea Warfare Center Division, Newport, Newport Rhode Island
1.2 Authorized Users
Code 7012 Survivability Test Laboratory
1.3 Sponsors
NUWCDIVNPT
1.4 Types of Funding
NUWCDIVNPT Overhead/Service Cost Center (SCC)
2.0 Scope
This contractor shall provide the services, equipment and material to repair Thermotron environmental test chambers and portable chillers on site at NUWCDIVNPT.
3.0 Applicable Documents
The contractor shall perform the tasking required in Section 4.0 in accordance with (IAW) the below Applicable Documents (ADs).
NUMBER TITLE REVISION/DATE APPLICABLE SOW
TASK
3.1 US CODE, TITLE 42,
CHAPTER 85,
SUBCHAPTER VI , §
7671g National recycling and emission reduction program.
All
3.2 Thermotron Operations
Manual for each unit listed in Section 4.0 below.
All
3.4 ISO/IEC 17025 2017 All
3.5 ANSI/NCSL Z-540-1 1994 All
4.0 Technical Requirements
The factory-authorized contractor shall repair the environmental test chambers and portable chillers in accordance with ADs in Section 3.0 and using Government Furnished Information (GFI) in Section 6.0.
The contractor shall maintain a Visit Request on file and Defense Biometric Identification Data System (DBIDS) to obtain unescorted access to the facility.
The contractor shall provide all the necessary tools and materials required to perform all work. The contractor shall be responsible for removal of any chemical waste that results from this contract. Prior to performing any “hotwork” (i.e. brazing, welding, or soldering), the Government Technical Point of Contact (TPOC) must be notified so that arrangements can be made with the facilities department to issue a burn permit and turn off the building smoke detectors. Hot Work permits are issued by the Newport Naval Station Fire Department and may require up to 24 hours’ notice to secure the fire alarm system.
All crane, forklift and rigging work will be performed by certified Government personnel. The contractor is not authorized to use the material handling equipment in the Government facility.
The contractor is prohibited from bringing computers with active 802.11 wireless devices, or computers with web camera installed on to NUWCDIVNPT at any time. No cell phones with cameras or recording capability are permitted in any NUWCDIVNPT facility.
4.1 Repairs
The contractor shall repair and service the following environmental test chambers and portable chillers at NUWCDIVNPT.
Thermotron Model Serial Number
SE-1000-15-15-RAC 50853
SE-1000-15-15 49825
SE-1000-15-15 49826
SE-1000-15-15 49827
SE-1000-15-15 49828
WS-600-CHM-30-30 49234
WS-400-CHM-30-30 51158
WS-400-CHM-30-30 53312
The chamber repairs are usually emergency repairs, therefore, response time is crucial. Upon arrival at the Government facility, the contractor will be provided with equipment documentation (GFI 6.1 and 6.2) and the Government’s Repair Schedule Requirement (GFI 6.3).
4.1.1 Upon diagnosing the problem, prior to initiating the repair, the contractor shall provide a written estimate to the Government TPOC for review and approval, in accordance with CDRL A001.
4.1.2 Upon Government approval of the contractor’s repair estimate, the contractor shall perform the repairs.
4.1.3 The contractor shall provide a temperature and humidity calibration certificate, and a preventative maintenance and service summary report in accordance with CDRLs A002 and A003, upon completion of repairs.
5.0 RESERVED
6.0 Government Furnished Information
The following GFI will be made available under this contract.
Number Title Applicable SOW Task
Number
6.1 Thermotron Operations/System Manual for each Environmental Chamber
ALL
6.2 Detailed schematics where available for each of the 14 Environmental Chambers, Chillers located in building 114.
ALL
6.3 Non-NUWCDIVNPT Owned Computer Equipment Form
ALL
7.0 Government Furnished Property
The Government will not provide Government Furnished Property (GFP).
8.0 RESERVED
9.0 RESERVED
10.0 Security Compliance
10.1 Program Protection
SECURITY: All Contractor personnel shall adhere to the Security provisions of 32 CFR Part 117
– National Industrial Security Program Operating Manual (NISPOM) and the security requirements of the attached DD254. While performing work associated with NUWCDIVNPT, Contractor personnel shall comply with the NUWCDIVNPT Security Manual and, if at another facility, the security regulations of the host facility. Applicable FAR, DFARS, NMCARS clauses, and NAVSEA text shall be adhered to in the performance of this contract. Security incidents shall be promptly reported through the companies Facility Security Officer (FSO), to the Contracting Officer’s Representative (COR), Technical Point of Contact (TPOC), and the Cognizant Security Office to NUWCDIVNPT Security.
Controlled Unclassified Information (CUI) including Legacy FOUO and Covered Defense Information (meeting the definition of 48 CFR 252.204–7012(a)) generated and/or provided under this contract shall be marked and safeguarded as specified in DoD Instruction 5200.48, CUI available at:
https://www.esd.whs.mil/Portals/54/Documents/DD/issuances/dodi/520048p.PDF. Any product containing Covered Defense Information shall be assigned a distribution statement (distribution statements B through F) in accordance with DoDI 5230.24 (Distribution Statements on Technical Documents); and DoDI 5230.24, Enclosure 3 Procedures, available at https://www.esd.whs.mil/Portals/54/Documents/DD/issuances/dodi/523024p.pdf
INFORMATION SECURITY: If the work is performed at the Contractor's facility, the Contractor shall implement and maintain security procedures and controls to prevent unauthorized disclosure of classified information and controlled unclassified information (CUI) and to control distribution of CUI in accordance with National Industrial Security Program Operating Manual (NISPOM) codifying 32 CFR Part 117, NISPOM Rule, and SECNAV M- 5510.36B. If the work is performed at the Government's facility, the Contractor shall comply with facility policy.
CUI INCIDENT REPORTING AND RESPONSE: The Contractor shall promptly report any unauthorized, inadvertent, or illegal release or disclosure of CUI to the Contracting Officer’s Representative / Technical Point of Contact (TPOC), Procuring Contracting Officer, and the Security Office. Contractor personnel shall coordinate this effort through the relevant industry site FSO.
PUBLIC RELEASE: Any controlled unclassified information pertaining to this contract shall not be released for public dissemination, including posting to any social media sites such as Facebook or Twitter, unless it has been approved for public release by appropriate U.S. Government authority.
Proposed public releases shall be submitted for approval prior to release through Commander, Naval Undersea Warfare Center Division, Newport, Newport, RI 02841.
10.2 Operations Security (OPSEC)
OPSEC is a process that identifies critical information to determine if friendly actions can be observed by adversary intelligence systems, determines if information obtained by adversaries could be interpreted to be useful to them, and then executes selected measures that eliminate or reduce adversary exploitation of friendly critical information.
The Contractor shall develop and implement, and update and maintain an OPSEC program to protect controlled unclassified and classified activities, information, equipment, and material used or developed by the Contractor and any subcontractor during performance of the contract.
The Contractor shall be responsible for the subcontractor implementation of the OPSEC requirements. The Contractor developed OPSEC program may include Information Assurance and Communications Security (COMSEC). The OPSEC program shall be in accordance with National Security Presidential Memorandum (NSPM) 28, and at a minimum shall include:
1) Assignment of responsibility for OPSEC direction and implementation.
2) Issuance of procedures and planning guidance for the use of OPSEC techniques to identify vulnerabilities and apply applicable countermeasures.
3) Establishment of OPSEC education and awareness training. To include initial and annual OPSEC training.
4) Provisions for management, annual review, and evaluation of OPSEC programs.
5) Flow down of OPSEC requirements to subcontractors when applicable.
While performing aboard Government sites, the contractor shall: comply with all OPSEC instructions and policies; include OPSEC as part of its ongoing security awareness program and take all required Agency training; Be responsive to the Supporting OPSEC Manager on a non-interference basis; and Protect sensitive unclassified information and activities, which could compromise classified information or operations, or degrade the planning and execution of operations performed by the Requiring Organization and contractor in support of the mission.
10.3 Electronic Spillage
Electronic Spillage (ES) is defined as a situation where information of higher classification than a system is authorized to process is introduced into that system, intentionally or otherwise. If a Contractor is determined to be responsible for an ES, all direct and indirect costs incurred by the Government for ES remediation will be charged to the Contractor.
File details come from the government source that posted it. Updated .