XTLF 19 1020 Repair CATM B901 Lighting Substitution Request.pdf
PDF 5 MB Posted
- Attached to
- Repair CATM-B901, Renovate Firing Range B903
- Solicitation number
- IFB259B
View the file
Other files
| File | Type | Posted |
|---|---|---|
| IFB259B PreBid Minutes Questions and Answers.pdf | ||
| Federal Supplement 6-28-17.doc | DOC document | |
| IFB259B Instructions to Offeror 2.doc | DOC document | |
| Plans XTLF19 1020 and XTLF19 1024.pdf | ||
| General Provisions.doc | DOC document | |
| W-9 as of november 2018 per the IRS.pdf | ||
| OK20200038 1-3-2020.pdf | ||
| IFB259B Solicitation and Offer.doc | DOC document | |
| Base Access Form 0916.pdf | ||
| Specs XTLF19 1020 and XTLF19 1024.pdf | ||
| Q A Form 004.doc | DOC document | |
| PR FRM 12 Rev 4 Reps and Certs 8 Jan 2018.doc | DOC document | |
| IFB259B Schedule B.doc | DOC document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
July 31, 2021
Vance AFB XTLF 19-1020 &19-1024 Repair CATM - B901 &
Renovate Firing Range - B903
Subject: Lighting Substitution Request
Question: Please review the attached fixture package to confirm compliance with requirements. Products included in this package are provided by Triple C Lighting.
Response: The package is approved as noted with following note.
Light fixtures require 10 year warranty.
Dewey Oard
Operations Electrical Engineer
07-31-2020
Date: Jul 30, 2020 Page 1/1
Transmittal
TRIPLE C LIGHTING AND CONTROLS
1212 W. Main Oklahoma City, OK 73106 Phone: (405) 235-5456 From: Misti Catlege
FF00009 Page 1/1
Project 23729 VANCE AFB B903 FIRING RANGE Quote# OKC20-72907 Location
Contact:
ATTACHED WE ARE SENDING YOU 1 COPY OF THE FOLLOWING ITEM:
Drawings Specifications Other: Substitutions Prints Information Plans Submittals
THESE ARE TRANSMITTED FOR:
X Prior Approval Resubmittal for Approval Record
Approval Corrections Bids due on:
Approval as Submitted Your Use Other:
Approval as Noted Review and Comment
Type MFG Part A Elite Lighting USA RL675-900L-DIMTR-40K-90-WH
Item Note: 6.6" CLIP DNLIGHT/WIDE OPTICS/15W/1014L/40K/90CRI/TRIAC/
WHT/120V
B Axis Lighting Inc PS-R-AS-LF-500-80-40-4'-W-UNV-DP-1-
MT-RWHD
Item Note: 4'/1/2" DIR-IND WALL LINEAR PLANK/60% ASY UP-40%
LAMBERTION DN/ALUM HSG/4.74WPF/500LPF/40K/80CRI/0-
10V-1%/1CIRC/WHT/120-277
BE Axis Lighting Inc PS-R-AS-LF-500-80-40-4'-W-UNV-DP-1-
MT-RWHD-B1
Item Note: 4'/1/2" DIR-IND WALL LINEAR PLANK/60% ASY UP-40%
LAMBERTION DN/ALUM HSG/4.74WPF/500LPF/40K/80CRI/0-
10V-1%/1CIRC/WHT/120-277/EM 1-4' SECTION
C Elite Lighting USA 14-FPL1-LED-3000L-DIM10-MVOLT-
40K-85/14-FPL1-LED-SMK
Item Note: 1X4 FLAT PANEL/SURFACE/30W/3051L/40K/85CRI/0-10V-1%/
WHT/120-277
CE Elite Lighting USA 14-FPL1-LED-3000L-DIM10-MVOLT-
40K-85-O-EMG-LED-10W/14-FPL1-
LED-SMK
Item Note: 1X4 FLAT PANEL/SURFACE/30W/3051L/40K/85CRI/0-10V-1%/
WHT/120-277/EM
E Elite Lighting USA ELX-603-R-W Item Note: PLASTIC LED EXIT/EM/UNIV/RED-WHT/120-277
Submitted by TRIPLE C LIGHTING AND CONTROLS
Job Name:
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
RL675-900L-DIMTR-40K-90-WH
Notes: 6.6" CLIP DNLIGHT/WIDE OPTICS/
15W/1014L/40K/90CRI/TRIAC/WHT/120V
Type:
A
OKC20-72907
SLIM SURFACE LED
Project Name:
Note: Type:
Catalog Number:
Submittal form is available @ www.iuseeliteled.com Tel: 323-888-1973 • Fax: 323-888-1977
Specifications and Dimensions subject to change without notice.
5/8” Thick Surface LED Fixture
Round LED Slim Surface Mount Dimmable Fixture
SPECIFICATIONS:
APERTURE 5.5” 7” 9” 11”
LUMENS 600 lumens 900 lumens 1200 lumens 1500 lumens
WATTAGE 10W 15W 18W 22W
CCT 30K/40K/50K
CRI 90
VOLTAGE 120V
POWER FREQUENCY 50/60 Hz
FINISH White
AMBIENT ENVIRONMENT Damp location
Ordering Information: Example: RL791-900L-DIMTR-120-30K/40K/50K-90-WH
FIELD SELECTABLE CCT SLIM SURFACE MOUNT DOWNLIGHT
SERIES/APERTURE/LUMENS
RL591-600L
RL791-900L
RL991-1200L
RL1191-1500L
- 5-3/8” aperture/600 lumens
- 7-7/8” aperture/900 lumens
- 9” aperture/1200 lumens
- 12” aperture/1500 lumens
CCT
30K/40K/50K - 3000K/4000K/500K
CRI
90 - 90+ CRI
VOLTAGE
120 - 120V
DIMMING
DIMTR - Triac
FINISH
WH
BZ
BN
- White
- Bronze
- Brushed Nickel
3.5” Round (Plastic)
Pancake J-Box (Metal)
4” Square (Plastic)
4” Octagonal (Metal)
4” Square (Metal)
Fire Rated J-Box
Note: A 2-1/8” deep octagon junction box is recommended for through circuit wiring applications.
Compatible Junction Boxes:
ENGINEERED FOR VERSATILITY AND PERFORMANCE
The Elite LED Slim Surface Mount has been engineered to install into most standard junctions boxes. Up to 1500 usable lumens are directed from the luminaire to the work surface. Easy to Install, applicable to Junction Box or Recessed Can Installation
OPTICS
The Elite LED Module system is much more than just a simple LED retrofit.
The Elite LED system is a highly engineered work of design and optical science which produces up to 1500 lumens. Our meticulously crafted optics gather the light scattered by the LED chip and shape it into a functional beam with uniform light distribution.
DIMMING
Intended for Triac (120V) base on configuration. Minimum 90º supply conductors.
COMPLIANCE
Non-conductive fixture for shower light application. Product complies with the requirements of the California Energy Commission regulated under Title 24.
LISTING
ETL listed for damp location (wet location - with covered ceilings) Energy Star certified
WARRANTY
The Elite LED lighting system carries a five-year carefree warranty for parts and components. (Labor not included)
12”
9”
7-7/8” 5-3/8”
Due to the changes of constant improvement in LED technology, all details are subject to change without notice. Consult factory for up to date information. w w w . i u s e e l i t e . c o m
6”6 Inch Round Slim LED
RL675
OPEN
4.1”
1.25”
3.3”
6”
5.9”
0.07”
.9”
6.6” 4.9”
6.8”
Cut hole in ceiling. Insert luminaire into opening by squeezing spring clips on both sides of luminaire. The width in ceiling needed for the driver to fit is 3”.
INSTALLATION
FEATURES
6” round LED “Slim Disk” engineered for new construction, remodel, or retrofit to accommodate insulated or dropped ceilings. Recessed housing not required, especially with limited plenum applications. Remote driver allows easy installation and maintenance. Small aperture and shallow depth are ideal for unlimited applications.
• IC-Rated and Air-Tight ready and may be in direct contact with insulation.
• Can be installed in applications with limited plenum clearance.
• May be installed in drywall or suspended ceilings.
• Flicker-free 120V forward-phase Triac dimming down to 5%.
• Even illumination of luminaire is achieved by utilizing patent-pending optics along with edgelit LED technology.
• Aluminum die-cast body and trim.
LUMENS
DIMMING
CCT
COLOR QUALITY
CRI
EMERGENCY
LIFETIME
CONSTRUCTION
TRIM OPTION
TRIM COLORS
700, 900
DIMTR (Triac)
27K, 30K, 35K, 40K, 50K
3-Step MacAdam Ellipse
90+
16W high voltage inverter
L70 at 50,000 Hours
Aluminum die-cast body and trim
Round Flat Lens
WH (White), BK (Black), BZ (Bronze), SN (Satin Nickel), CP (Copper), CH (Chrome)
PHOTOMETRIC TESTS In Accordance with IES LM79-08, LM80 and TM-30, TM-21
NOMINAL LUMENS DELIVERED LUMENS WATTAGE
700 789 14W
900 1014 15W
Based on 4000K, 90+ CRI. Actual wattage may vary +/- 5%
Index Page1/3Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
RL675-900L-DIMTR-40K-90-WH
Notes: 6.6" CLIP DNLIGHT/WIDE OPTICS/
15W/1014L/40K/90CRI/TRIAC/WHT/120V
Type:
A
OKC20-72907
Due to the changes of constant improvement in LED technology, all details are subject to change without notice. Consult factory for up to date information. w w w . i u s e e l i t e . c o m
6”6 Inch Round Slim LED
RL675
ACCESSORIES
o RL675-RT-BZ-Bronze o RL675-RT-BK-Black o RL675-RT-CH-Chrome o RL675-RT-CP-Copper o RL675-RT-SN-Satin Nickel
OPTIONS
o RL-ACC-SLIM-1-10F - 10ft Long Extension o RL-ACC-SLIM-1-20F - 20ft Long Extension o RL-UNV-4/5/6 - Universal Mounting Plate for 4”,5” and 6” o RL-ACC-SLIM-6-ROUGHPLATE - 6” Mounting Plate
EXAMPLE: RL675-900L-DIMTR-120-3OK-90-WH RL675-RT-BZ RL-ACC-SLIM-1-10F
2”
I S S U E 1 5 G 2 1 R e v . 0 . 1
WWW.IUSEELITE.COM • TEL 1-877-375-5555 • FAX 1-877-375-3333
S H I P P I N G AVA I L A B L E
1” GIMBAL LED FIXTURE WITH REFLECTOR
w 1-5/8” THICK LED FIXTURE WITH HIGHER BRIGHTNESS w FOR NEW CONSTRUCTION – INSULATED AND DROPPED CEILINGS w FEATURES 1” fixtures with integral LEDs. Isolated external driver factory installed inside junction box.
One driver for every fixture required. PF>0.98.
w Cast aluminum trim w Dimmable w ETL approved and Energy Star Certified w Type IC Rated – Approved for direct contact with insulation w Air-tight and damp location approved w Fast and easy to install in limited space locations w External driver factory mounted inside connection box - 120V w New construction rough-in plates and jumper cables available w Available Temperatures (3000K, 3500K and 4000K) w 50,000 Hours Life; 5 Year Warranty
TECHNICAL SPECIFICATIONS
w WATTAGES: 5W w OUTPUT: Default Driver Voltage: 120V AC 60 Hz (Dimmable) w CRI: 90+ w AMBIENT TEMPERATURE: -40°F (-40°C) to +104°F (+40°C) w ADJUSTABLE: 30º tilt and 360º rotation
CERTIFICATIONS
• ETL listed
• ENERGY STAR
INSTALLATION
• Cut hole in ceiling and snap fixture in opening with attached spring clips. Space in ceiling needed for the driver to fit through the ceiling height – 3".
DIMENSION
INPUT VOLT. INPUT FREQ. THD POWER FACTOR INPUT POWER LUMENS
120 60Hz <20% >0.98 5W(+/-5%) 360L
12-7/8”
2-3/4”
1-3/4”
2”
TYPE LUMEN CCT CRI FINISH ACCESSORIES
RL173 o 360L-DIMTR-120 o 30K o 35K o 40K
90+ WH o RL-ACC-SLIM-1-10F o RL-ACC-SLIM-1-20F
EXAMPLE: RL173-360L-DIMTR-120-30K-90-WH
RL-ACC-SLIM-1-10F
10-ft long extension
RL-ACC-SLIM-1-20F
20-ft long extension
IN
C
H
L E
D
R E
T R
O F
IT
M O
D U
L E
RL173 LED
1” GIMBAL LED FIXTURE WITH REFLECTOR
2-1/2”
1-5/8”
(Bronze)
(Black)
(Chrome
(Copper)
(Satin Nickel)
RL675-RT-BZ
RL675-RT-BK
RL675-RT-CH
RL675-RT-CP
RL675-RT-SN
SLIM TRIM TRIM RINGS ACCESSORIES
RL-ACC-SLIM-6-ROUGHPLATE
Rough-in plate for use with 6” downlights
15-1/8” 13-1/8”
3-7/8”
3-3/4”
7-3/4”
6” Opening 5” Opening 4” Opening
RL-UNV-4/5/6
For use with: 4”, 5”, 6”
Universal mounting plate
TYPE LUMEN CCT CRI FINISH
RL675 o 700L-DIMTR-120 o 900L-DIMTR-120 o 27K o 30K o 35K o 40K o 50K o 90+ o WH (White)
26"
8 38 "
4 3 16 "
13"
6 1116 "
16 "
5 3 16 "
RL-ACC-SLIM-5-ROUGHPLATE
26"
8 38 "
4 3 16 "
6 1116 "
16 "
13" 6 14 "
RL-ACC-SLIM-6-ROUGHPLATE
7 34 "
27"
13 12 "
9 12 "
4 34 "
7 1316 "
16 "RL-ACC-SLIM-8-ROUGHPLATE
26” 13”
4-3/16” 8-3/8”
6-1/4”
6-11/16”
3/16”
Index Page2/3Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
RL675-900L-DIMTR-40K-90-WH
Notes: 6.6" CLIP DNLIGHT/WIDE OPTICS/
15W/1014L/40K/90CRI/TRIAC/WHT/120V
Type:
A
OKC20-72907
Due to the changes of constant improvement in LED technology, all details are subject to change without notice. Consult factory for up to date information. w w w . i u s e e l i t e . c o m
6”6 Inch Round Slim LED
RL675
RL675-700L-DIMTR-120-35K-90-BK TEST NO.: EL09051928
INPUT WATTS: 14.3065 LUMENS: 789 CRI: 90 EFFICACY: 55 CCT: 3500K SPACING CRITERIA: 1.18
Candle Power Distribution (Candelas)
RC - Ceiling Cavity Reflectance RW - Wall Reflectance
R O
O M
C A
VI
TY
R A
TI
O
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20
Zonal Lumens Summary
Candela TabulationLumens Per Zone
Zone Lumens
0-10 39.59 10-20 108.92 20-30 152.57 30-40 163.93 40-50 145.43 50-60 105.99 60-70 57.59 70-80 13.74 80-90 0.03
Luminance (Average candela/M2) Angle in Degrees
Average 0º
Average 45º
Average 90º
45 87858 90162 94045 55 66339 69264 73710 65 41179 44953 50339 75 8570 12644 19481 85 79 79 79
0 422.31 5 417.51 15 384.07 25 326.78 35 255.88 45 181.49 55 111.16 65 50.84 75 6.48 85 0.02 90 0.03
RC 80% 70% 50% 30% 10% 0%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 1 111 107 104 101 109 105 102 99 101 98 96 97 95 93 94 92 91 89 2 103 96 90 86 100 94 89 85 91 86 83 88 84 81 85 82 79 77 3 95 86 79 74 93 85 78 73 82 76 72 79 74 71 77 73 69 67 4 88 78 70 64 86 76 69 64 74 68 63 72 66 62 70 65 61 59 5 82 70 62 56 80 69 62 56 67 61 56 65 59 55 63 58 54 53 6 76 64 56 50 74 63 55 50 61 55 50 60 54 49 58 53 49 47 7 71 58 51 45 69 58 50 45 56 49 45 55 49 44 54 48 44 42 8 66 54 46 41 65 53 46 41 52 45 40 51 45 40 50 44 40 38 9 62 50 42 37 61 49 42 37 48 41 37 47 41 37 46 40 36 35
10 58 46 39 34 57 46 39 34 45 38 34 44 38 34 43 37 33 32
Zone Lumens %Lamp %Fixt
0-20 148.51 18.80 18.80 0-30 301.08 38.20 38.20 0-40 465.01 59.00 59.00 0-60 716.44 90.90 90.90 0-80 787.77 99.90 99.90 0-90 787.80 99.90 99.90
90º
80º
70º
60º
50º
40º
30º 20º
10º
Cone of Light
BEAM DIA. MEASURED AT 50% OF NADIR F.C.
(FT.)Distance to Plane
(FC.) Initial Footcandle at Nadir (FT.) Beam
Vert. Spread (FT.) Beam
Horiz. Spread
2 106 3.6 3.6
4 26.4 7.2 7.2
6 11.7 10.8 10.8
8 6.6 14.4 14.3
10 4.22 18 17.9
12 2.93 21.6 21.5
RL675-900L-DIMTR-120-30K-90-SN TEST NO.: EL11191959
INPUT WATTS: 14.8543 LUMENS: 1014 CRI: 90 EFFICACY: 68 CCT: 3000K SPACING CRITERIA: 1.18
Candle Power Distribution (Candelas)
RC - Ceiling Cavity Reflectance RW - Wall Reflectance
R O
O M
C A
VI
TY
R A
TI
O
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20
Zonal Lumens Summary
Candela TabulationLumens Per Zone
Zone Lumens
0-10 50.04 10-20 137.75 20-30 193.42 30-40 208.72 40-50 186.64 50-60 137.95 60-70 77.72 70-80 20.40 80-90 0.03
Luminance (Average candela/M2) Angle in Degrees
Average 0º
Average 45º
Average 90º
45 111235 113558 119222 55 85078 88283 94806 65 55774 59816 67089 75 15143 19548 29996 85 79 79 79
0 533.67 5 526.77 15 483.20 25 411.02 35 322.37 45 229.78 55 142.56 65 68.86 75 11.45 85 0.02 90 0.03
RC 80% 70% 50% 30% 10% 0%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 1 111 107 104 101 108 105 102 99 101 98 96 97 95 93 93 92 90 88 2 103 96 90 85 100 94 89 84 91 86 82 87 84 81 84 81 79 77 3 95 86 79 73 92 84 78 73 81 76 71 79 74 70 76 72 69 67 4 88 77 69 64 85 76 69 63 73 67 62 71 66 62 69 65 61 59 5 81 70 62 56 79 69 61 56 67 60 55 65 59 55 63 58 54 52 6 75 64 55 50 74 63 55 49 61 54 49 59 53 49 58 52 48 46 7 70 58 50 45 69 57 50 44 56 49 44 54 48 44 53 48 43 42 8 66 53 46 40 64 53 45 40 51 45 40 50 44 40 49 44 39 38 9 62 49 42 37 60 49 41 37 48 41 36 47 41 36 46 40 36 34
10 58 46 38 34 57 45 38 33 44 38 33 43 37 33 43 37 33 31
Zone Lumens %Lamp %Fixt
0-20 187.79 18.50 18.50 0-30 381.22 37.60 37.60 0-40 589.93 58.20 58.20 0-60 914.52 90.20 90.20 0-80 1012.64 99.90 99.90 0-90 1012.67 99.90 99.90
90º
80º
70º
60º
50º
40º
30º 20º
10º
Cone of Light
BEAM DIA. MEASURED AT 50% OF NADIR F.C.
(FT.)Distance to Plane
(FC.) Initial Footcandle at Nadir (FT.) Beam
Vert. Spread (FT.) Beam
Horiz. Spread
2 133 3.6 3.6
4 33.4 7.3 7.3
6 14.8 10.9 10.9
8 8.34 14.5 14.6
10 5.34 18.2 18.2
12 3.71 21.8 21.8
Index Page3/3Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
PS-R-AS-LF-500-80-40-4'-W-UNV-DP
1-MT-RWHD
Notes: 4'/1/2" DIR-IND WALL LINEAR PLANK/60% ASY UP-
40% LAMBERTION DN/ALUM HSG/4.74WPF/500LPF/40K/
Type:
B
OKC20-72907
Ordering Guide
© 2016 Axis Lighting Inc.
1 . 8 0 0 . 2 6 3 . 2 9 4 7 [T] 514 . 9 4 8 . 6 27 2
Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications.
Contact Axis for the latest product information.
1 / 7 FILE NAME : Pose.SPEC February 18, 2020
POSE™ WALL AND SURFACE MOUNT
a x i s l i g h t i n g . c o m
4 15/16"
3 1/4"1 3/8" 1/2"
1 1/4"
Right Angle (R) - wall mount Right Angle (R) - surface mount
Notes
Type
Project
MOUNTING SIDE
RIGHT
ANGLE
(R)
STEP (S)
CIRCUITS MOUNTING ORIENTATION REMOTE BATTERY
(OPTIONAL)
OTHER
(OPTIONAL)
CUSTOM
(OPTIONAL)
1 1 circuit MT mounting track for drywall and solid surfaces* (#) orientation B(#) remote F fuse C custom 2 2 circuits* DF drywall flange* battery pack
+E(#) emergency circuit* DS drywall spackle flange* SB9 surface TB 9/16** SBS surface screw slot t-bar**
*Specify quantity 4' lenghth min;
* Can not control up/down separately.
Not available on 15/16 T-bars *For wall or ceiling mounting.
** Ceiling mounting only.
Please consult factory for power feed options available for your ceiling type and application.
See page 2 for orientation options
Remote only Requires 120V or 277V
Please specify
PS
PRODUCT ID MOUNTING SIDE OPTIC-STEP SIDE OPTIC-FLAT SIDE NOM. LUMENS/FT
PS Pose R right angle AS asymmetric - step side AF asymmetric - flat side 250 250 lm/ft S step LS lambertian - step side LF lambertian - flat side 500 500 lm/ft
850 850 lm/ft 1000 1000 lm/ft
See light distribution options above AS & LS comes with UB ultra blend lens
See light distribution options above AF & LF comes with UB ultra blend lens
Outputs between listed min and max are available.
Consult factory for outputs outside of the listed range.
CRI COLOR TEMP. LENGTH FINISH VOLTAGE DRIVER
80 80 CRI 27 2700 K 2 2’ AP aluminum paint 120 120 V DP dimming (0-10V) 1% - integral 90 90 CRI 30 3000 K 3 3’ W white 277 277 V
35 3500 K 4 4’* BLK black 347 347 V* 40 4000 K 5 5’ C custom UNV universal
6 6’ S(#) system run**
Consult factory for other color temperatures
2ft min, 1 ft increment, 6 ft max stand alone.
* For RIGHT ANGLE WALL MOUNT - 2ft min, 1 ft increment, 4 ft max stand alone. See page 2 for more details.
**System runs contain joiners - see page 3 For all other lengths and related outputs, please consult factory.
* Remote driver only. Integral driver
LIGHT DISTRIBUTION
STEP SIDE
FLAT SIDE
*See page 6 for photometryNOTE: Rotate distribution 90° when luminaire is mounted on ceiling.
asymmetric on step side
LUMENS %
50% lambertian on step side
LUMENS %
50% asymmetric on step side
LUMENS %
60% lambertian on step side
LUMENS %
40% asymmetric on flat side
50% lambertian on flat side
50% lambertian on flat side
40% asymmetric on flat side
60%
AS AS
AF AF
LS LS
LF LF
Orientation example
Right Angle Wall Vertical Right
RWVR
WALL SURFACE (CEILING)
Please provide elevation view See page 2 for orientation options
Step (S) - wall mount
NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY
250 lm/ft 2.37 W/ft 105 lm/W 500 lm/ft 4.74 W/ft 105 lm/W 850 lm/ft 8.06 W/ft 105 lm/W 1000 lm/ft 9.49 W/ft 105 lm/W Please consult factory for custom lumen output and wattage.
PERFORMANCE PER LINEAR FOOT AT 3500K
WITH ALL OPTICS OPTIONS
RWHD
Index Page1/7Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
PS-R-AS-LF-500-80-40-4'-W-UNV-DP
1-MT-RWHD
Notes: 4'/1/2" DIR-IND WALL LINEAR PLANK/60% ASY UP-
40% LAMBERTION DN/ALUM HSG/4.74WPF/500LPF/40K/
Type:
B
OKC20-72907
© 2016 Axis Lighting Inc.
1 . 8 0 0 . 2 6 3 . 2 9 4 7 [T] 514 . 9 4 8 . 6 27 2
Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications.
Contact Axis for the latest product information.
2 / 7 FILE NAME : Pose.SPEC February 18, 2020 a x i s l i g h t i n g . c o m
POSE™ WALL AND SURFACE MOUNT
ORIENTATION OPTIONS
WALL
SURFACEHORIZONTAL VERTICAL
DOWN UP LEFT RIGHT
RIGHT ANGLE
MOUNT (R)
*Max 4ft increments available
*Max 4ft increments available
*Max 4ft increments available
*Max 4ft increments available *Max 6ft increments available
Right Angle SurfaceRight Angle Wall Horizontal Down
Right Angle Wall Horizontal Up
Right Angle Wall Vertical Left
Right Angle Wall Vertical Right
RWHD RWHU RWVL RWVR RS
STEP MOUNT (S)
(recommend lambertian (LS) on the step side)
*Max 6ft increments available
*Max 6ft increments available
*Max 6ft increments available
*Max 6ft increments
N/A
Step Wall
Step Wall Horizontal Up
Step Wall Vertical Left
Step Wall Vertical Right
SWHD SWHU SWVL SWVR
(Note: These orientations help orient installation by the contractor. If you indicate an orientation in your product code it will be placed on the shop drawings)
LIGHT DISTRIBUTION (EXAMPLE AF-AS 1000 LUMENS 500 LUMENS UP, 500 LUMENS DOWN)
STEP SIDE
FLAT SIDE
*See page 6 for photometryNOTE: Rotate distribution 90° when luminaire is mounted on ceiling.
asymmetric on step side
LUMENS %
50% lambertian on step side
LUMENS %
50% asymmetric on step side
LUMENS %
60% lambertian on step side
LUMENS %
40% asymmetric on flat side
50% lambertian on flat side
50% lambertian on flat side
40% asymmetric on flat side
60%
AS AS
AF AF
LS LS
LF LF
RIGHT ANGLE WALL MOUNT SPECIFICATIONS
2 ft Minimum length for stand alone fixture.
3 ft Stand alone fixture.
4 ft Maximum length for stand alone fixture.
6 ft System run of two 3 ft segments with joiner.
8 ft System run of two 4 ft segments with joiner
12 ft System run of three 4 ft segments with two joiners
2'
3'
3' 3'
4'
6'
8'
12'
4'
4'
4'
4' 4'
Index Page2/7Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
PS-R-AS-LF-500-80-40-4'-W-UNV-DP
1-MT-RWHD
Notes: 4'/1/2" DIR-IND WALL LINEAR PLANK/60% ASY UP-
40% LAMBERTION DN/ALUM HSG/4.74WPF/500LPF/40K/
Type:
B
OKC20-72907
© 2016 Axis Lighting Inc.
1 . 8 0 0 . 2 6 3 . 2 9 4 7 [T] 514 . 9 4 8 . 6 27 2
Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications.
Contact Axis for the latest product information.
3 / 7 FILE NAME : Pose.SPEC February 18, 2020 a x i s l i g h t i n g . c o m
POSE™ WALL AND SURFACE MOUNT
LED SYSTEM
CRI Minimum 80 or 90 color rendering index.
CCT Choice of 2700K, 3000K, 3500K and 4000K color temperature with a great color consistency (within 3–step MacAdam ellipse). Both within fixture and fixture to fixture.
LED life Minimum 50,000h with 85% of lumen maintenance in 250C ambient temperature, in compliance with IES LM-80 testing measurements.
Thermal Management
Aluminum housing acting as the heat sink to maximize life.
Environment Dry and damp rated in operating ambient temperatures of 0-400C (32-104F).
POSE linear systems, with the use of a strong profile, allow for a connection system of continuous runs.
With Step Side Wall mounting and Surface Right Angle Side mounting lengths of 2ft min, 1ft increments, 6 ft max stand alone , as well as custom lengths are available.
Attention! For Right Angle Side Wall Mount lengths of 2ft min, 1ft increments, 4ft max stand alone are available (See Right angle Wall mount specifications chart on page 2).
Runs of POSE that are greater than 6' or 4' in length are designated as systems (S#).
This means that the run is comprised of a combination of sections to be assembled on site using our joining system.
For more information on systems and joining, please refer to the POSE installation sheets available for download at www.
axislighting.com.
SYSTEM (S#)
Axis Lighting will warrant defective LEDs, boards, and drivers for 5 years from date of purchase. Warranty is valid if luminaire is installed and used according to specifications.
If defective, Axis will send replacement boards or drivers at no cost along with detailed replacement instructions and instructions on how to return defective components to Axis.
WARRANTY
CONSTRUCTION
Housing Extruded aluminum (0.05'' nominal) Up to 70% recycled content End Cap Cast aluminum Interior Brackets Die formed sheet steel (22 gauge) Reflectors White powder coated sheet steel (24 gauge) Lenses Extruded acrylic (0.070'' nominal)
SPECIFICATIONS OPTICS
UB Ultra Blend Lens
ELECTRICAL
Emergency Remote emergency battery pack or emergency circuit optional.
Input Voltage 120V, 277V, 347V (remote), UNV.
Incorporating these components may have limitations or affect the length of the luminaire, please contact factory for more details.
Index Page3/7Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
PS-R-AS-LF-500-80-40-4'-W-UNV-DP
1-MT-RWHD
Notes: 4'/1/2" DIR-IND WALL LINEAR PLANK/60% ASY UP-
40% LAMBERTION DN/ALUM HSG/4.74WPF/500LPF/40K/
Type:
B
OKC20-72907
© 2016 Axis Lighting Inc.
1 . 8 0 0 . 2 6 3 . 2 9 4 7 [T] 514 . 9 4 8 . 6 27 2
Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications.
Contact Axis for the latest product information.
4 / 7 FILE NAME : Pose.SPEC February 18, 2020 a x i s l i g h t i n g . c o m
POSE™ WALL AND SURFACE MOUNT
ATTACH FIXTURE
Remove cover. Align fi xture mounting holes with anchoring bolts on track system.
Tighten to secure.
Minimal design, clean installation
INSTALL
MOUNTING TRACK
Position, level and fasten Pose track system to the wall or ceiling.
POWER
Make electrical connection.
COVER, SET
AND LIGHT IT UP!
Snap in cover and tighten set screw.
1 2
SURFACE MOUNT
TRACK (MT)
DRYWALL FLANGE
(DF)*
DRYWALL SPACKLE
(DS)
0.3” off set from wall or surface Flush with wall Flush with wall
Mounting fl exibility, multiple application solutions Choose from surface mount (MT) or recessed mount (DF) or spackle mount (DS) tracks.
*min 5/8 thick drywall
0.3”
Index Page4/7Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
PS-R-AS-LF-500-80-40-4'-W-UNV-DP
1-MT-RWHD
Notes: 4'/1/2" DIR-IND WALL LINEAR PLANK/60% ASY UP-
40% LAMBERTION DN/ALUM HSG/4.74WPF/500LPF/40K/
Type:
B
OKC20-72907
© 2016 Axis Lighting Inc.
1 . 8 0 0 . 2 6 3 . 2 9 4 7 [T] 514 . 9 4 8 . 6 27 2
Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications.
Contact Axis for the latest product information.
5 / 7 FILE NAME : Pose.SPEC February 18, 2020 a x i s l i g h t i n g . c o m
POSE™ WALL AND SURFACE MOUNT
0° 90°
150180
PHOTOMETRIC DATA
PHOTOMETRIC CURVE
750 lm/ft Uplight 60%
500 lm/ft Downlight 40% with Flush lens Horizontal Angles
Vertical Angle 0 22.5 45 67.5 90
0 700 700 700 700 700 5 697 699 701 701 701 15 672 677 682 685 686 25 626 632 639 644 645 35 558 564 572 578 579 45 470 477 483 490 490 55 368 373 378 383 383 65 254 258 263 266 267 75 137 141 146 148 149 85 38 38 39 39 38 90 1 9 17 21 22 95 34 60 75 80 80 105 220 258 306 347 366 115 466 561 681 797 851 125 585 730 946 1161 1256 135 599 728 921 1127 1218 145 586 679 804 927 982 155 575 635 701 765 791 165 570 603 633 659 668 175 567 576 586 594 596 180 567 567 567 567 567
CANDELA DISTRIBUTION LUMINANCE DATA (cd/m2)
Horizontal Angles
Vertical Angle 0 45 90
45 6870 7057 7161 55 6627 6806 6896 65 6215 6435 6529 75 5478 5844 5931 85 4446 4665 4488
ZONAL LUMENS
Lumens
Zone
0-10 66 10-20 190 20-30 288 30-40 349 40-50 364 50-60 331 60-70 257 70-80 154 80-90 48
90 50 90-100 245 100-110 517 110-120 637 120-130 561 130-140 420 140-150 285 150-160 165 160-170 54 170-180 109
Lumen/ft up: 734 lm/ft Lumen/ft down: 512 lm/ft Total Lumens: 4985 lm (for 4ft) Input Watts: 47.44 W Efficacy: 105 lm/W
80 CRI shown. For 90 CRI, divide wattage by 0.8 and multiply efficacy by 0.8.
IES FILE: POSE-4-S-AS-LF-80-3500-W-120-DP-1.IES
TESTED ACCORDING TO IES LM-79-2008
All IES files are available for download at: www.axislighting.com asymmetric on step side
LUMENS %
60% lambertian on flat side
40%
AS
LF
Index Page5/7Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
PS-R-AS-LF-500-80-40-4'-W-UNV-DP
1-MT-RWHD
Notes: 4'/1/2" DIR-IND WALL LINEAR PLANK/60% ASY UP-
40% LAMBERTION DN/ALUM HSG/4.74WPF/500LPF/40K/
Type:
B
OKC20-72907
© 2016 Axis Lighting Inc.
1 . 8 0 0 . 2 6 3 . 2 9 4 7 [T] 514 . 9 4 8 . 6 27 2
Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications.
Contact Axis for the latest product information.
6 / 7 FILE NAME : Pose.SPEC February 18, 2020 a x i s l i g h t i n g . c o m
POSE™ WALL AND SURFACE MOUNT
0° 90°
150180
PHOTOMETRIC CURVE
600 lm/ft Uplight 50%
600 lm/ft Downlight 50% Horizontal Angles
Vertical Angle 0 22.5 45 67.5 90
0 825 825 825 825 825 5 822 824 825 826 824 15 792 796 799 802 802 25 733 739 745 750 750 35 651 657 664 669 670 45 547 551 558 563 564 55 426 430 434 439 439 65 293 296 301 304 305 75 157 161 166 168 168 85 42 42 43 42 41 90 1 11 20 25 27 95 44 71 89 98 101 105 169 199 219 231 234 115 312 340 357 370 372 125 450 477 493 505 507 135 575 600 617 628 630 145 682 705 721 731 732 155 766 785 799 807 808 165 824 837 848 853 853 175 853 857 862 865 863 180 856 856 856 856 856
CANDELA DISTRIBUTION LUMINANCE DATA (cd/m2)
Horizontal Angles
Vertical Angle 0 45 90
45 7991 8147 8240 55 7676 7817 7907 65 7170 7352 7447 75 6277 6626 6723 85 4968 5094 4892
ZONAL LUMENS
Lumens
Zone
0-10 78 10-20 223 20-30 338 30-40 409 40-50 425 50-60 386 60-70 299 70-80 180 80-90 57
90 51 90-100 156 100-110 280 110-120 373 120-130 419 130-140 409 140-150 343 150-160 229 160-170 81 170-180 109
Lumen/ft up: 585 lm/ft Lumen/ft down: 599 lm/ft Total Lumens: 4736 lm (for 4ft) Input Watts: 47.45 W Efficacy: 100 lm/W
80 CRI shown. For 90 CRI, divide wattage by 0.8 and multiply efficacy by 0.8.
IES FILE: POSE-4-S-LF-LS- 80-3500-W- 120-DP-1.IES
TESTED ACCORDING TO IES LM-79-2008
All IES files are available for download at: www.axislighting.com
PHOTOMETRIC DATA
lambertian on step side
LUMENS %
50% lambertian on flat side
50%
LS
Index Page6/7Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
PS-R-AS-LF-500-80-40-4'-W-UNV-DP
1-MT-RWHD
Notes: 4'/1/2" DIR-IND WALL LINEAR PLANK/60% ASY UP-
40% LAMBERTION DN/ALUM HSG/4.74WPF/500LPF/40K/
Type:
B
OKC20-72907
© 2016 Axis Lighting Inc.
1 . 8 0 0 . 2 6 3 . 2 9 4 7 [T] 514 . 9 4 8 . 6 27 2
Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications.
Contact Axis for the latest product information.
7 / 7 FILE NAME : Pose.SPEC February 18, 2020 a x i s l i g h t i n g . c o m
POSE™ WALL AND SURFACE MOUNT
asymmetric on step side
LUMENS %
50% asymmetric on flat side
50%AF
AS
0° 90°
150180
PHOTOMETRIC CURVE
600 lm/ft Uplight 50%
600 lm/ft Downlight 50% Horizontal Angles
Vertical Angle 0 22.5 45 67.5 90
0 349 349 349 349 349 5 351 350 352 352 354 15 358 364 378 391 397 25 376 396 439 479 496 35 409 455 544 628 660 45 463 544 694 847 909 55 511 625 831 1050 1147 65 458 560 726 905 984 75 237 281 352 438 476 85 37 47 64 82 90 90 1 10 20 26 28 95 33 65 86 98 103 105 211 267 336 399 427 115 439 559 712 863 932 125 523 684 925 1167 1277 135 493 632 841 1057 1153 145 442 542 676 806 864 155 403 466 541 607 635 165 381 414 450 477 489 175 371 379 389 396 399 180 370 370 370 370 370
CANDELA DISTRIBUTION LUMINANCE DATA (cd/m2)
Horizontal Angles
Vertical Angle 0 45 90
45 6767 10139 13273 55 9195 14969 20649 65 11181 17746 24032 75 9467 14063 18997 85 4429 7603 10685
ZONAL LUMENS
Lumens
Zone
0-10 34 10-20 108 20-30 197 30-40 310 40-50 454 50-60 592 60-70 557 70-80 303 80-90 67
90 54 90-100 245 100-110 510 110-120 606 120-130 498 130-140 342 140-150 212 150-160 113 160-170 36 170-180 109
Lumen/ft up: 654 lm/ft Lumen/ft down: 656 lm/ft Total Lumens: 5238 lm (for 4ft) Input Watts: 47.5 W Efficacy: 110 lm/W
80 CRI shown. For 90 CRI, divide wattage by 0.8 and multiply efficacy by 0.8.
IES FILE: POSE-4-S-AS-AF-80-3500-W-120-DP-1.IES
TESTED ACCORDING TO IES LM-79-2008
PHOTOMETRIC DATA
Index Page7/7Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
PS-R-AS-LF-500-80-40-4'-W-UNV-DP
1-MT-RWHD-B1
Notes: 4'/1/2" DIR-IND WALL LINEAR PLANK/60% ASY UP-
40% LAMBERTION DN/ALUM HSG/4.74WPF/500LPF/40K/
Type:
BE
OKC20-72907
Ordering Guide
© 2016 Axis Lighting Inc.
1 . 8 0 0 . 2 6 3 . 2 9 4 7 [T] 514 . 9 4 8 . 6 27 2
Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications.
Contact Axis for the latest product information.
1 / 7 FILE NAME : Pose.SPEC February 18, 2020
POSE™ WALL AND SURFACE MOUNT
a x i s l i g h t i n g . c o m
4 15/16"
3 1/4"1 3/8" 1/2"
1 1/4"
Right Angle (R) - wall mount Right Angle (R) - surface mount
Notes
Type
Project
MOUNTING SIDE
RIGHT
ANGLE
(R)
STEP (S)
CIRCUITS MOUNTING ORIENTATION REMOTE BATTERY
(OPTIONAL)
OTHER
(OPTIONAL)
CUSTOM
(OPTIONAL)
1 1 circuit MT mounting track for drywall and solid surfaces* (#) orientation B(#) remote F fuse C custom 2 2 circuits* DF drywall flange* battery pack
+E(#) emergency circuit* DS drywall spackle flange* SB9 surface TB 9/16** SBS surface screw slot t-bar**
*Specify quantity 4' lenghth min;
* Can not control up/down separately.
Not available on 15/16 T-bars *For wall or ceiling mounting.
** Ceiling mounting only.
Please consult factory for power feed options available for your ceiling type and application.
See page 2 for orientation options
Remote only Requires 120V or 277V
Please specify
PS
PRODUCT ID MOUNTING SIDE OPTIC-STEP SIDE OPTIC-FLAT SIDE NOM. LUMENS/FT
PS Pose R right angle AS asymmetric - step side AF asymmetric - flat side 250 250 lm/ft S step LS lambertian - step side LF lambertian - flat side 500 500 lm/ft
850 850 lm/ft 1000 1000 lm/ft
See light distribution options above AS & LS comes with UB ultra blend lens
See light distribution options above AF & LF comes with UB ultra blend lens
Outputs between listed min and max are available.
Consult factory for outputs outside of the listed range.
CRI COLOR TEMP. LENGTH FINISH VOLTAGE DRIVER
80 80 CRI 27 2700 K 2 2’ AP aluminum paint 120 120 V DP dimming (0-10V) 1% - integral 90 90 CRI 30 3000 K 3 3’ W white 277 277 V
35 3500 K 4 4’* BLK black 347 347 V* 40 4000 K 5 5’ C custom UNV universal
6 6’ S(#) system run**
Consult factory for other color temperatures
2ft min, 1 ft increment, 6 ft max stand alone.
* For RIGHT ANGLE WALL MOUNT - 2ft min, 1 ft increment, 4 ft max stand alone. See page 2 for more details.
**System runs contain joiners - see page 3 For all other lengths and related outputs, please consult factory.
* Remote driver only. Integral driver
LIGHT DISTRIBUTION
STEP SIDE
FLAT SIDE
*See page 6 for photometryNOTE: Rotate distribution 90° when luminaire is mounted on ceiling.
asymmetric on step side
LUMENS %
50% lambertian on step side
LUMENS %
50% asymmetric on step side
LUMENS %
60% lambertian on step side
LUMENS %
40% asymmetric on flat side
50% lambertian on flat side
50% lambertian on flat side
40% asymmetric on flat side
60%
AS AS
AF AF
LS LS
LF LF
Orientation example
Right Angle Wall Vertical Right
RWVR
WALL SURFACE (CEILING)
Please provide elevation view See page 2 for orientation options
Step (S) - wall mount
NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY
250 lm/ft 2.37 W/ft 105 lm/W 500 lm/ft 4.74 W/ft 105 lm/W 850 lm/ft 8.06 W/ft 105 lm/W 1000 lm/ft 9.49 W/ft 105 lm/W Please consult factory for custom lumen output and wattage.
PERFORMANCE PER LINEAR FOOT AT 3500K
WITH ALL OPTICS OPTIONS
RWHD
Index Page1/7Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
PS-R-AS-LF-500-80-40-4'-W-UNV-DP
1-MT-RWHD-B1
Notes: 4'/1/2" DIR-IND WALL LINEAR PLANK/60% ASY UP-
40% LAMBERTION DN/ALUM HSG/4.74WPF/500LPF/40K/
Type:
BE
OKC20-72907
© 2016 Axis Lighting Inc.
1 . 8 0 0 . 2 6 3 . 2 9 4 7 [T] 514 . 9 4 8 . 6 27 2
Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications.
Contact Axis for the latest product information.
2 / 7 FILE NAME : Pose.SPEC February 18, 2020 a x i s l i g h t i n g . c o m
POSE™ WALL AND SURFACE MOUNT
ORIENTATION OPTIONS
WALL
SURFACEHORIZONTAL VERTICAL
DOWN UP LEFT RIGHT
RIGHT ANGLE
MOUNT (R)
*Max 4ft increments available
*Max 4ft increments available
*Max 4ft increments available
*Max 4ft increments
*Max 6ft increments available
Right Angle SurfaceRight Angle Wall
Right Angle Wall Horizontal Up
Right Angle Wall Vertical Left
Right Angle Wall Vertical Right
RWHD RWHU RWVL RWVR RS
STEP MOUNT (S)
(recommend lambertian (LS) on the step side)
*Max 6ft increments available
*Max 6ft increments available
*Max 6ft increments available
*Max 6ft increments
N/A
Step Wall
Step Wall Horizontal Up
Step Wall Vertical Left
Step Wall Vertical Right
SWHD SWHU SWVL SWVR
(Note: These orientations help orient installation by the contractor. If you indicate an orientation in your product code it will be placed on the shop drawings)
LIGHT DISTRIBUTION (EXAMPLE AF-AS 1000 LUMENS 500 LUMENS UP, 500 LUMENS DOWN)
STEP SIDE
FLAT SIDE
*See page 6 for photometryNOTE: Rotate distribution 90° when luminaire is mounted on ceiling.
asymmetric on step side
LUMENS %
50% lambertian on step side
LUMENS %
50% asymmetric on step side
LUMENS %
60% lambertian on step side
LUMENS %
40% asymmetric on flat side
50% lambertian on flat side
50% lambertian on flat side
40% asymmetric on flat side
60%
AS AS
AF AF
LS LS
LF LF
RIGHT ANGLE WALL MOUNT SPECIFICATIONS
2 ft Minimum length for stand alone fixture.
3 ft Stand alone fixture.
4 ft Maximum length for stand alone fixture.
6 ft System run of two 3 ft segments with joiner.
8 ft System run of two 4 ft segments with joiner
12 ft System run of three 4 ft segments with two joiners
2'
3'
3' 3'
4'
6'
8'
12'
4'
4'
4'
4' 4'
Index Page2/7Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
PS-R-AS-LF-500-80-40-4'-W-UNV-DP
1-MT-RWHD-B1
Notes: 4'/1/2" DIR-IND WALL LINEAR PLANK/60% ASY UP-
40% LAMBERTION DN/ALUM HSG/4.74WPF/500LPF/40K/
Type:
BE
OKC20-72907
© 2016 Axis Lighting Inc.
1 . 8 0 0 . 2 6 3 . 2 9 4 7 [T] 514 . 9 4 8 . 6 27 2
Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications.
Contact Axis for the latest product information.
3 / 7 FILE NAME : Pose.SPEC February 18, 2020 a x i s l i g h t i n g . c o m
POSE™ WALL AND SURFACE MOUNT
LED SYSTEM
CRI Minimum 80 or 90 color rendering index.
CCT Choice of 2700K, 3000K, 3500K and 4000K color temperature with a great color consistency (within 3–step MacAdam ellipse). Both within fixture and fixture to fixture.
LED life Minimum 50,000h with 85% of lumen maintenance in 250C ambient temperature, in compliance with IES LM-80 testing measurements.
Thermal Management
Aluminum housing acting as the heat sink to maximize life.
Environment Dry and damp rated in operating ambient temperatures of 0-400C (32-104F).
POSE linear systems, with the use of a strong profile, allow for a connection system of continuous runs.
With Step Side Wall mounting and Surface Right Angle Side mounting lengths of 2ft min, 1ft increments, 6 ft max stand alone , as well as custom lengths are available.
Attention! For Right Angle Side Wall Mount lengths of 2ft min, 1ft increments, 4ft max stand alone are available (See Right angle Wall mount specifications chart on page 2).
Runs of POSE that are greater than 6' or 4' in length are designated as systems (S#).
This means that the run is comprised of a combination of sections to be assembled on site using our joining system.
For more information on systems and joining, please refer to the POSE installation sheets available for download at www.
axislighting.com.
SYSTEM (S#)
Axis Lighting will warrant defective LEDs, boards, and drivers for 5 years from date of purchase. Warranty is valid if luminaire is installed and used according to specifications.
If defective, Axis will send replacement boards or drivers at no cost along with detailed replacement instructions and instructions on how to return defective components to Axis.
WARRANTY
CONSTRUCTION
Housing Extruded aluminum (0.05'' nominal) Up to 70% recycled content End Cap Cast aluminum Interior Brackets Die formed sheet steel (22 gauge) Reflectors White powder coated sheet steel (24 gauge) Lenses Extruded acrylic (0.070'' nominal)
SPECIFICATIONS OPTICS
UB Ultra Blend Lens
ELECTRICAL
Emergency Remote emergency battery pack or emergency circuit optional.
Input Voltage 120V, 277V, 347V (remote), UNV.
Incorporating these components may have limitations or affect the length of the luminaire, please contact factory for more details.
Index Page3/7Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
PS-R-AS-LF-500-80-40-4'-W-UNV-DP
1-MT-RWHD-B1
Notes: 4'/1/2" DIR-IND WALL LINEAR PLANK/60% ASY UP-
40% LAMBERTION DN/ALUM HSG/4.74WPF/500LPF/40K/
Type:
BE
OKC20-72907
© 2016 Axis Lighting Inc.
1 . 8 0 0 . 2 6 3 . 2 9 4 7 [T] 514 . 9 4 8 . 6 27 2
Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications.
Contact Axis for the latest product information.
4 / 7 FILE NAME : Pose.SPEC February 18, 2020 a x i s l i g h t i n g . c o m
POSE™ WALL AND SURFACE MOUNT
ATTACH FIXTURE
Remove cover. Align fi xture mounting holes with anchoring bolts on track system.
Tighten to secure.
Minimal design, clean installation
INSTALL
MOUNTING TRACK
Position, level and fasten Pose track system to the wall or ceiling.
POWER
Make electrical connection.
COVER, SET
AND LIGHT IT UP!
Snap in cover and tighten set screw.
1 2
SURFACE MOUNT
TRACK (MT)
DRYWALL FLANGE
(DF)*
DRYWALL SPACKLE
(DS)
0.3” off set from wall or surface Flush with wall Flush with wall
Mounting fl exibility, multiple application solutions Choose from surface mount (MT) or recessed mount (DF) or spackle mount (DS) tracks.
*min 5/8 thick drywall
0.3”
Index Page4/7Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
PS-R-AS-LF-500-80-40-4'-W-UNV-DP
1-MT-RWHD-B1
Notes: 4'/1/2" DIR-IND WALL LINEAR PLANK/60% ASY UP-
40% LAMBERTION DN/ALUM HSG/4.74WPF/500LPF/40K/
Type:
BE
OKC20-72907
© 2016 Axis Lighting Inc.
1 . 8 0 0 . 2 6 3 . 2 9 4 7 [T] 514 . 9 4 8 . 6 27 2
Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications.
Contact Axis for the latest product information.
5 / 7 FILE NAME : Pose.SPEC February 18, 2020 a x i s l i g h t i n g . c o m
POSE™ WALL AND SURFACE MOUNT
0° 90°
150180
PHOTOMETRIC DATA
PHOTOMETRIC CURVE
750 lm/ft Uplight 60%
500 lm/ft Downlight 40% with Flush lens Horizontal Angles
Vertical Angle 0 22.5 45 67.5 90
0 700 700 700 700 700 5 697 699 701 701 701 15 672 677 682 685 686 25 626 632 639 644 645 35 558 564 572 578 579 45 470 477 483 490 490 55 368 373 378 383 383 65 254 258 263 266 267 75 137 141 146 148 149 85 38 38 39 39 38 90 1 9 17 21 22 95 34 60 75 80 80 105 220 258 306 347 366 115 466 561 681 797 851 125 585 730 946 1161 1256 135 599 728 921 1127 1218 145 586 679 804 927 982 155 575 635 701 765 791 165 570 603 633 659 668 175 567 576 586 594 596 180 567 567 567 567 567
CANDELA DISTRIBUTION LUMINANCE DATA (cd/m2)
Horizontal Angles
Vertical Angle 0 45 90
45 6870 7057 7161 55 6627 6806 6896 65 6215 6435 6529 75 5478 5844 5931 85 4446 4665 4488
ZONAL LUMENS
Lumens
Zone
0-10 66 10-20 190 20-30 288 30-40 349 40-50 364 50-60 331 60-70 257 70-80 154 80-90 48
90 50 90-100 245 100-110 517 110-120 637 120-130 561 130-140 420 140-150 285 150-160 165 160-170 54 170-180 109
Lumen/ft up: 734 lm/ft Lumen/ft down: 512 lm/ft Total Lumens: 4985 lm (for 4ft) Input Watts: 47.44 W Efficacy: 105 lm/W
80 CRI shown. For 90 CRI, divide wattage by 0.8 and multiply efficacy by 0.8.
IES FILE: POSE-4-S-AS-LF-80-3500-W-120-DP-1.IES
TESTED ACCORDING TO IES LM-79-2008
All IES files are available for download at: www.axislighting.com asymmetric on step side
LUMENS %
60% lambertian on flat side
40%
AS
Index Page5/7Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
PS-R-AS-LF-500-80-40-4'-W-UNV-DP
1-MT-RWHD-B1
Notes: 4'/1/2" DIR-IND WALL LINEAR PLANK/60% ASY UP-
40% LAMBERTION DN/ALUM HSG/4.74WPF/500LPF/40K/
Type:
BE
OKC20-72907
© 2016 Axis Lighting Inc.
1 . 8 0 0 . 2 6 3 . 2 9 4 7 [T] 514 . 9 4 8 . 6 27 2
Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications.
Contact Axis for the latest product information.
6 / 7 FILE NAME : Pose.SPEC February 18, 2020 a x i s l i g h t i n g . c o m
POSE™ WALL AND SURFACE MOUNT
0° 90°
150180
PHOTOMETRIC CURVE
600 lm/ft Uplight 50%
600 lm/ft Downlight 50% Horizontal Angles
Vertical Angle 0 22.5 45 67.5 90
0 825 825 825 825 825 5 822 824 825 826 824 15 792 796 799 802 802 25 733 739 745 750 750 35 651 657 664 669 670 45 547 551 558 563 564 55 426 430 434 439 439 65 293 296 301 304 305 75 157 161 166 168 168 85 42 42 43 42 41 90 1 11 20 25 27 95 44 71 89 98 101 105 169 199 219 231 234 115 312 340 357 370 372 125 450 477 493 505 507 135 575 600 617 628 630 145 682 705 721 731 732 155 766 785 799 807 808 165 824 837 848 853 853 175 853 857 862 865 863 180 856 856 856 856 856
CANDELA DISTRIBUTION LUMINANCE DATA (cd/m2)
Horizontal Angles
Vertical Angle 0 45 90
45 7991 8147 8240 55 7676 7817 7907 65 7170 7352 7447 75 6277 6626 6723 85 4968 5094 4892
ZONAL LUMENS
Lumens
Zone
0-10 78 10-20 223 20-30 338 30-40 409 40-50 425 50-60 386 60-70 299 70-80 180 80-90 57
90 51 90-100 156 100-110 280 110-120 373 120-130 419 130-140 409 140-150 343 150-160 229 160-170 81 170-180 109
Lumen/ft up: 585 lm/ft Lumen/ft down: 599 lm/ft Total Lumens: 4736 lm (for 4ft) Input Watts: 47.45 W Efficacy: 100 lm/W
80 CRI shown. For 90 CRI, divide wattage by 0.8 and multiply efficacy by 0.8.
IES FILE: POSE-4-S-LF-LS- 80-3500-W- 120-DP-1.IES
TESTED ACCORDING TO IES LM-79-2008
All IES files are available for download at: www.axislighting.com
PHOTOMETRIC DATA
lambertian on step side
LUMENS %
50% lambertian on flat side
50%
LS
Index Page6/7Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
PS-R-AS-LF-500-80-40-4'-W-UNV-DP
1-MT-RWHD-B1
Notes: 4'/1/2" DIR-IND WALL LINEAR PLANK/60% ASY UP-
40% LAMBERTION DN/ALUM HSG/4.74WPF/500LPF/40K/
Type:
BE
OKC20-72907
© 2016 Axis Lighting Inc.
1 . 8 0 0 . 2 6 3 . 2 9 4 7 [T] 514 . 9 4 8 . 6 27 2
Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications.
Contact Axis for the latest product information.
7 / 7 FILE NAME : Pose.SPEC February 18, 2020 a x i s l i g h t i n g . c o m
POSE™ WALL AND SURFACE MOUNT
asymmetric on step side
LUMENS %
50% asymmetric on flat side
50%AF
AS
0° 90°
150180
PHOTOMETRIC CURVE
600 lm/ft Uplight 50%
600 lm/ft Downlight 50% Horizontal Angles
Vertical Angle 0 22.5 45 67.5 90
0 349 349 349 349 349 5 351 350 352 352 354 15 358 364 378 391 397 25 376 396 439 479 496 35 409 455 544 628 660 45 463 544 694 847 909 55 511 625 831 1050 1147 65 458 560 726 905 984 75 237 281 352 438 476 85 37 47 64 82 90 90 1 10 20 26 28 95 33 65 86 98 103 105 211 267 336 399 427 115 439 559 712 863 932 125 523 684 925 1167 1277 135 493 632 841 1057 1153 145 442 542 676 806 864 155 403 466 541 607 635 165 381 414 450 477 489 175 371 379 389 396 399 180 370 370 370 370 370
CANDELA DISTRIBUTION LUMINANCE DATA (cd/m2)
Horizontal Angles
Vertical Angle 0 45 90
45 6767 10139 13273 55 9195 14969 20649 65 11181 17746 24032 75 9467 14063 18997 85 4429 7603 10685
ZONAL LUMENS
Lumens
Zone
0-10 34 10-20 108 20-30 197 30-40 310 40-50 454 50-60 592 60-70 557 70-80 303 80-90 67
90 54 90-100 245 100-110 510 110-120 606 120-130 498 130-140 342 140-150 212 150-160 113 160-170 36 170-180 109
Lumen/ft up: 654 lm/ft Lumen/ft down: 656 lm/ft Total Lumens: 5238 lm (for 4ft) Input Watts: 47.5 W Efficacy: 110 lm/W
80 CRI shown. For 90 CRI, divide wattage by 0.8 and multiply efficacy by 0.8.
IES FILE: POSE-4-S-AS-AF-80-3500-W-120-DP-1.IES
TESTED ACCORDING TO IES LM-79-2008
PHOTOMETRIC DATA
Index Page7/7Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
14-FPL1-LED-3000L-DIM10-MVOLT-
40K-85/14-FPL1-LED-SMK
Notes: 1X4 FLAT PANEL/SURFACE/30W/
3051L/40K/85CRI/0-10V-1%/WHT/120-277
Type:
C
OKC20-72907
Due to the changes of constant improvement in LED technology, all details are subject to change without notice. Consult factory for up to date information. w w w . i u s e e l i t e . c o m
By Elite Lighting
EMERGENCY
LUMENS
DIMMING &
CONTROL
COLOR QUALITY
SIZE
MOUNTING
CRI
LIFETIME
PHOTOMETRIC TESTS
CCT
3000, 4000, 5000
10W - Up to 1000L output (Bodine BSL310) 20W - Up to 2000L output (Bodine BSL20)
0-10V Flicker Free 1% Dimming Standard (DIM10), LUTH, LUTFTB, LUT2W, DIMST, ELDO10.1, ELDODMX.1, DALI.1
30K, 35K, 40K, 50K
3 Step MacAdam Ellipse
2’x4’, 2’x2’, 1’x4’
Recessed, Suspended, Surface Mount
85+
L70 at 60,000 Hours
In Accordance with IES LM79-08, LM80 and TM-30, TM-21
FEATURES
This fully luminous LED flat panel delivers exceptional performance and aesthetically pleasing optics, optimizing shallow plenum spaces. Perfect for new construction applications or retrofitting existing fluorescent troffer luminaires. It offers a range of dimming, lumen and CCT options. Perfect for either recessed or surface mounted installations, it’s an ideal choice for commercial office space, retail merchandising, educational, and healthcare facilities.
1’ x 4’ Architectural LED Flat Panel 14-FPL1-LED 1’x4’
NOMINAL LUMENS DELIVERED LUMENS WATTAGE
5000 5090 50 W
4000 4076 40 W
3000 3051 30 W
Based on 4000K, 85+ CRI. Actual wattage may vary +/- 5%
0.47"
2"
45.35"
21.34" 23.7"
47.7"
0.47"
2"
1.6"
3.1"11.7"
1.6"
3.1"11.7"
1.6"
3.1"11.7"
21.34"
21.34" 23.7"
23.7"
0.47"
2"
45.35"
9.35" 11.7"
47.7"
Index Page1/4Submitted On: Jul 29, 2020
23729 VANCE AFB B903 FIRING RANGE
Architect/Engineer: Vance AFB
Catalog Number:
14-FPL1-LED-3000L-DIM10-MVOLT-
40K-85/14-FPL1-LED-SMK
Notes: 1X4 FLAT PANEL/SURFACE/30W/
3051L/40K/85CRI/0-10V-1%/WHT/120-277
Type:
C
OKC20-72907
By Elite Lighting
Due to the changes of constant improvement in LED technology, all details are subject to change without notice. Consult factory for up to date information. w w w . i u s e e l i t e . c o m
MAINTENANCE
LED engines and drivers are removable and upgradable even after luminaire installation. Luminaire can be regularly and safely wiped down to ensure optimal performance.
OPTICAL SYSTEM
The proprietary optical system utilizes a unique combination of reflective and refractive optical components to achieve a uniform, aesthetically pleasing appearance. Use of a light guide plate creates even, glare-free illumination, while maintaining high efficiency.
CONSTRUCTION
Heavy duty 20-gauge cold rolled steel back panel and aluminum frame, post-painted and engineered for maximum strength and extended life. All corners interlock to prevent aesthetic damage to the luminaire, with sides and corners uniformly turned in and hemmed to remove sharp edges for safe handling and easy installation. Luminaire is supplied with multiple wiring entrances for easy daisy chain of luminaires, to add power packs, whips, or other accessories in the field, or for continuous row mounting.
FINISH
Post-painted with a 93% reflective white coat to improve luminaire efficacy, with all body components seamlessly interlocked for added structural strength.
MOUNTING
Luminaires accommodate lay-in ceilings, Slot T, and T-bar suspension systems for 5/8” and 3/8” ceiling thicknesses. Four corner tie points are standard for safety wire support when required, with built-in earthquake clips, standard. Luminaires may be available with flange kits, surface mounted kits, and other options.
OPTIONS
Luminaires can be shipped pre-installed with whips, modular wiring systems, daylight harvesting controls, occupancy sensors, and/or power packs for individual or room control applications.
DRIVER ELECTRICAL INFORMATION
Powered by high-quality constant-current power LED drivers which are rated for 50 to 60Hz at 120/277V input. Available in 347V., produce less than 20% THD, and have a power factor of .90 to 1.00.
DIMMING & DRIVER INFORMATION
DIM10 - Flicker Free 1% Dimming Standard (DIM10) 0-10V dimming on either MVOLT 120, 277 or 347V.
LUT2W - Lutron LTEA2W Hi-Lume 1%. 2-wire LED Driver Forward Phase Control, 1% dimming in 120V only. Available on all luminaires up to 40 watts.
LUTH - Lutron LDE1 Hi-Lume Eco System. 1% dimming with Soft in Fade to Black dimming technology.
ELDO10.1 - EldoLED SoloDrive 0-10V. Dimming down to 0.1%. Available on all luminaires up to 100 watts.
DALI - DALI DT6, DT8 dimming down to 1%. Available on all luminaires up to 100 watts.
ELDODMX - EldoLED PowerDrive dimming down to 0.1%. Available on all luminaires up to 100 watts.
Please see EldoLED website for wiring diagrams…