IFB 74-24 Specification.pdf
PDF 301 KB Posted
- Attached to
- IFB 74-24 Adjustable Cast Plates
- Solicitation number
- BD-24-1206-40000-40000-100326
- Issued by
- Suffolk County, Boston City, Massachusetts
About this file
This document is a material specification from the Massachusetts Bay Transportation Authority's (MBTA) Maintenance of Way Division for Resilient Fastener 115/132 Tie Plates. The specification outlines the required materials, manufacturing, inspection, and delivery requirements for the tie plates, which are to be used on the MBTA's transit lines. The tie plates must conform to AREMA standards and MBTA Plan No. 231, and are subject to inspection upon delivery. Delivery requirements include secure stacking on pallets or in wood crates, with rejection of plates delivered in cardboard boxes.
The related state and local contract opportunity is IFB 74-24 Adjustable Cast Plates, which is being issued by the MBTA and is applicable to Suffolk County and the City of Boston. The contract is for the supply of the specified Resilient Fastener 115/132 Tie Plates, but no further details on quantities, pricing, or other terms are provided in the given information.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| IFB 74-24 Minimum_Insurance_Requirements.pdf | ||
| IFB 74-24 Bid Document.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MBTA M.O.W. Division Approved:
Material Specification _________________________________________
June 2001 Manager of Track Engineering
MASSACHUSETTS BAY TRANSPORTATION AUTHORITY
MAINTENANCE OF WAY DIVISION
TRACK MATERIAL SPECIFICATION
Resilient Fastener 115/132 Tie Plate
MATERIALS
New resilient fastener tie plate shall conform to the AREMA Manual for Railway
Engineering, Chapter 5, Part 1 – Specification for Low-Carbon Steel Tie Plates and comply with all specifications designated on MBTA Plan No. 231.
MANUFACTURE
Each resilient fastener tie plate shall be new, “as rolled steel”, have 4 hole punching, and shall be in accordance with MBTA Plan No. 231 in the Book of Standard Trackwork
Plans. Plates are flat ¾” Low-Carbon Steel with approved Pandrol type “e” weld on shoulders per above referenced plan.
INSPECTION
Resilient fastener tie plates are subject to inspection at delivery for compliance with these specifications.
SHIPMENT
Resilient fastener tie plates shall be stacked neatly on pallets and securely banded with a sufficient number of 2” x 0.05” heavy duty steel bands to prevent the plates from shifting on the pallet while in shipment or being handled upon receipt. If steel banded cannot be provided, tie plates shall be delivered in wood crate pallet and neatly stacked up as an alternative method. Delivery in cardboard box will be rejected and sent back to the supplier at the supplier’s expense.
DELIVERY
To be accepted, trackwork delivered to the MBTA shall conform to these Specifications in all respects. Material is at the supplier’s risk until accepted at the specified delivery site by an authorized representative of the MBTA. Material rejected for non-compliance with these Specifications will be returned to the supplier wholly at the supplier’s expense.
M.O.W.
DIVISION
CAST RESTRAINING RAIL
115/132RE TIE PLATE
21"
19"
1-1/2"
4"
1"
5"
8"
1" DIA.
(4 LOC.)
0.63"
0.77"
10-7/8"
1-5/8" FOR GREEN LINE (USE 0.56" POST NYLON INSULATOR - PANDROL PART NO. 3456-2)
1-7/8" FOR RAPID TRANSIT LINES (USE 0.315" POST NYLON INSULATOR - PANDROL PART NO. 4263)
N.T.S
BLOCK
ASSEMBLY
(BY OTHER)
NOTES:
1. TIE PLATES SHALL CONFORM TO CURRENT
A.R.E.M.A SPECIFICATIONS.
2.MATERIAL SHALL BE LOW-CARBON STEEL
3. APPROXIMATE WEIGHT IS 33.8 LB.
4. LETTER "G" SHALL BE ON THE GAGE SIDE OF THE
PLATE. (PANDROL ITEM 13096 OR EQUAL)
| SPEC_115_132_DoubleShoulderPlate Feb. 2018 |
| STP - 231 Restraining Rail Plate |
File details come from the government source that posted it. Updated .