IFB_160775_VDOT_Culpeper_District_Entrance_DRAWINGS.pdf
PDF 9 MB Posted
- Attached to
- 160775 Culpeper District Front Entrance
- Solicitation number
- IFB-116966
- Issued by
- Craig County, Virginia
About this file
This document set comprises architectural and engineering drawings for the Culpeper District Entrance Project (Project Code: 501-B4501-002) submitted by the Virginia Department of Transportation (VDOT). The project involves site entrance security modifications including construction of a guard house at 1601 Orange Road, Culpeper, Virginia 22701. The scope of work includes demolition of existing site features, grading and site preparation, installation of a prefabricated guard house structure (8'-8" in height, 64 gross square feet), construction of concrete sidewalks and asphalt pavement, installation of bollards, barrier arms, chain link fencing (6' tall vinyl-coated), automatic sliding gate with operator, access control systems, and electrical and communications infrastructure. The project is governed by the 2021 Virginia Uniform Statewide Building Code and applicable Virginia construction codes. The entrance will remain closed for the duration of construction with VDOT providing closure and wayfinding to an alternate entrance. The design includes a delegated guard house system that must comply with specified load criteria and a design soil bearing capacity of 1,500 PSF. Asbestos inspection was performed with no asbestos-containing materials found; a lead-based paint inspection report is included as an appendix to the project manual.
The construction documents specify material requirements including 3,500 PSI concrete for footings and 5,000 PSI concrete for the guard house slab, welded wire fabric reinforcement, isolation joints, and vapor barriers. Electrical work includes installation of a new panelboard (Panel HA), site lighting fixtures with photocell and time clock control, underground electrical and communications conduits with pull boxes, grounding systems, and branch circuits for the guard house, sliding gate operator, barrier arms, and Knox Medvault units. Site lighting design complies with Virginia Energy Conservation Code allowances for parking areas and drives. Construction is typically permitted between 7:00 AM and 3:30 PM Monday through Friday, with coordination required for special events. The contractor is responsible for site safety and security, pre-demolition documentation, maintenance of as-built drawings, and compliance with all environmental and safety regulations including Virginia OSHA requirements. The project manual references specification section 133423.16 for the fabricated guard house and includes detailed requirements for concrete testing, inspection, and curing procedures.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| IFB_160775_VDOT_Culpeper_District_Entrance_PROJECT_MANUALrev1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VDOT
DRAWING LIST:
ASBESTOS DISCLOSURE STATEMENT:
LEAD PAINT DISCLOSURE STATEMENT:
DISCLAIMER STATEMENT:
VIRGINIA A&E ASSUMES NO RESPONSIBILITY FOR THE ADEQUACY OR ACCURACY OF THE ASBESTOS AND LEAD BASED PAINT INFORMATION PROVIDED ABOVE BY THE OWNER. THE CONTRACTOR SHALL ADDRESS ANY RELATED QUESTIONS TO THE OWNER'S PROJECT MANAGER.
DRAWING NO TITLE
T1 TITLE SHEET
C1 EXISTING CONDITIONS AND DEMOLITION PLAN
C2 SITE AND GRADING PLAN
C3 DETAILS
AS1 ENLARGED SITE PLAN AND DETAILS
AS2 GUARD HOUSE PLANS, ELEVATION, AND DETAILS
AS3 GENERAL NOTES
E1 LEGEND, ABBREVIATIONS, AND SPECIFICATIONS
E2 POWER AND LIGHTING PLAN
E3 ENLARGED SITE PLAN
E4 BASEMENT FLOOR PLAN
E5 DETAILS
E6 SCHEDULES
E7 CALCULATIONS
AN ASBESTOS INSPECTION WAS PERFORMED AND NO ACM WAS FOUND. THE ASBESTOS INSPECTION REPORT IS INCLUDED AS AN APPENDIX TO THE PROJECT MANUAL. SHOULD THE CONTRACTOR ACCESS ANY MATERIALS SUSPECTED OF CONTAINING ASBESTOS NOT IDENTIFIED IN THE REPORT DURING THE WORK, HE SHALL STOP WORK IN THE IMMEDIATE AREA AND NOTIFY THE OWNER.
AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS HAS BEEN CONDUCTED AND CAN BE FOUND AS AN APPENDIX TO THE PROJECT MANUAL. THIS REPORT IS PROVIDED FOR THE CONTRACTOR'S USE AND MAY NOT BE ALL INCLUSIVE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO EMPLOYEE EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE RECYCLED TO THE EXTENT
POSSIBLE.
CULPEPER DISTRICT ENTRANCE
PROJECT CODE: 501-B4501-002
CULPEPER, VIRGINIA
FOR CONSTRUCTION
MARCH 13, 2026
Drawing No.:
Project No.:
1"
Full Scale Verification
0"
T1
23135
VIRGINIA A&E, PLLC
1115 VISTA PARK DRIVE
FOREST, VA 24551
PHONE: (434) 316-6001
VAE PROJECT NO: 23135
SITE LOCATION NORTH
PROJECT LOCATION MAP
SITE
NORTH
VICINITY MAP
GENERAL INFORMATION:
FIRE SUPPRESSION SYSTEM:
WET
DRY
CHEMICAL
OTHER
NONE
NOT REQUIRED
ELEVATORS:
NEW
EXISTING
OTHER CONVEYORS: FIRE ALARM SYSTEM:
AUTOMATIC
MANUAL
NONE
NOT REQUIRED
(0) (0)
NEW
EXISTING
(0) (0)
PROJECT INFORMATION:
AGENCY: VIRGINIA DEPARTMENT OF TRANSPORTATION
PROJECT TITLE: CULPEPER DISTRICT ENTRANCE
PROJECT CODE: 501-B4501-002
ADDRESS: 1601 ORANGE ROAD, CULPEPER, VIRGINIA 22701
BUILDING INFORMATION:
BUILDING NAME/NUMBER: GUARD HOUSE
WORK PERMITTED: SITE ENTRANCE SECURITY MODIFICATIONS INCLUDING A GUARD HOUSE
PURPOSE/OCCUPANCY: SECURITY STAFFING OCCUPANCY
USE GROUP CLASSIFICATION: (B) BUSINESS (INDUSTRIALIZED BUILDING) OCCUPANCY
TYPE OF CONSTRUCTION: VB
OCCUPANT LOAD OF BUILDING: 1 OCCUPANTS PER VUSBC
BUILDING HEIGHT (FEET): 8'-8"± ABOVE GRADE
NUMBER OF STORIES: 1
GROSS AREA (GSF): 64 GROSS SQUARE FEET
BUILDING VOLUME: 512 CUBIC FEET
CODE MODIFICATIONS ISSUED: 1. WAIVER FOR GUARD HOUSE ACCESSIBILITY DUE TO STAFF PERFORMANCE
CRITERIA.
APPLICABLE CODES & STANDARDS:
BUILDING CODES: 2021 VIRGINIA UNIFORM STATEWIDE BUILDING CODE - VUSBC
(EFFECTIVE JANUARY 18, 2024)
VIRGINIA CONSTRUCTION CODE - VCC (2021)
VIRGINIA ENERGY CONSERVATION CODE - VECC (2021)
VIRGINIA MECHANICAL CODE - VMC (2021)
VIRGINIA STATEWIDE FIRE PREVENTION CODE - VSFPC (2021)
VIRGINIA EXISTING BUILDING CODE - VEBC (2021)
NATIONAL ELECTRICAL CODE - NFPA-70 (2020)
NATIONAL FIRE ALARM CODE - NFPA-72 (2019)
OTHER STANDARDS: CONSTRUCTION AND PROFESSIONAL SERVICES MANUAL - CPSM 2025 EDITION, REVISION 0
(MARCH 17, 2025)
STRUCTURAL LOAD CRITERIA: REFER TO DRAWING AS3.
GENERAL NOTES:
1. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED FOR USE AS
FABRICATION DRAWINGS. THESE DRAWINGS INDICATE THE GENERAL AND APPROXIMATE SIZE
AND LOCATION OF MATERIAL. FIELD VERIFY ALL DIMENSIONS AND LOCATIONS PRIOR TO
BEGINNING WORK. ALL UTILITIES NOTED ON PLANS ARE APPROXIMATE AND CONTRACTOR
SHALL FIELD VERIFY LOCATION.
2. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO, THE 2021 VIRGINIA UNIFORM STATEWIDE BUILDING CODE
(JANUARY 18, 2024) AND ASSOCIATED CODES OF REFERENCE. REFER TO APPLICABLE CODES
LIST THIS DRAWING.
3. ALL MATERIAL SHALL BE NEW UNLESS OTHERWISE NOTED. NO ASBESTOS CONTAINING
MATERIALS SHALL BE USED. MATERIALS ARE BASED ON THE INDICATED
MANUFACTURER'S/MODELS AND ARE INTENDED ONLY TO SHOW THE GENERAL SIZE,
CONFIGURATION, LOCATION, CONNECTIONS, AND SUPPORT FOR INDICATED MATERIAL WITH
RELATION TO OTHER BUILDING SYSTEMS. MATERIAL BY ANY MANUFACTURER THAT MEETS THE
SCHEDULED CRITERIA IS ACCEPTABLE. CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATING ACTUAL INSTALLED MATERIAL AND ASSOCIATED CHANGES.
4. CONTRACTOR SHALL COORDINATE THE WORK WITH EXISTING CONDITIONS, INCLUDING BEAMS, COLUMNS, SITE FEATURES, AND OTHER OBSTRUCTIONS, WHETHER OR NOT SUCH IS SHOWN ON
DRAWINGS.
5. CONTACT VIRGINIA 811 AT 1-800-552-7001, OR HTTPS://WWW.VA811.COM NO LESS THAN 72
HOURS PRIOR TO EXCAVATION AND DO NOT DISTURB THE SOIL UNTIL DIG TICKET HAS BEEN
PROCESSED.
6. CONTRACTOR SHALL COORDINATE THE WORK BETWEEN ALL TRADES. MATERIAL LOCATIONS
SHALL BE COORDINATED BETWEEN CIVIL, ARCHITECTURAL, STRUCTURAL, ELECTRICAL, AND
DEMOLITION PLANS TO AVOID CONFLICTS.
7. EXISTING MATERIAL TO BE REMOVED SHALL BE REMOVED CAREFULLY TO AVOID DAMAGING
MATERIAL TO REMAIN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE THAT OCCURS
TO EXISTING MATERIAL TO REMAIN OR TO BE RELOCATED DURING DEMOLITION AND
CONSTRUCTION.
8. CONTRACTOR SHALL ADVISE THE A/E IMMEDIATELY OF DISCREPANCIES FOUND ON THE
DRAWINGS, IN THE SPECIFICATIONS, OR BETWEEN THE TWO. MINOR DEVIATIONS FROM THE
PLANS MAY BE MADE TO AVOID MINOR CONFLICTS. WHERE MAJOR CONFLICTS ARE
ENCOUNTERED, THE AFFECTED WORK SHALL NOT BE INSTALLED UNTIL THE CONFLICT HAS
BEEN RESOLVED. NEITHER THE A/E NOR THE OWNER SHALL BE RESPONSIBLE FOR
CONSEQUENCES OF PROCEEDING WITH WORK BASED ON CONTRACTOR INTERPRETATION OR
ON DIRECTION FROM OTHER PARTIES, INCLUDING THE OWNER AND INSPECTORS.
9. ALL MATERIAL SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S WRITTEN INSTALLATION
INSTRUCTIONS, MAINTAINING ALL REQUIRED CLEARANCES AND WITH ALL COMPONENTS
ACCESSIBLE AND SERVICEABLE.
10. CONTRACTOR SHALL PROVIDE MATERIAL DATA SUBMITTALS FOR ALL NEW MATERIAL. REFER TO
INDIVIDUAL DRAWINGS FOR ADDITIONAL SUBMITTAL REQUIREMENTS.
11. CONTRACTOR SHALL BE RESPONSIBLE FOR ASSEMBLING OPERATION AND MAINTENANCE
MANUALS CONTAINING ALL MATERIAL SUBMITTALS, INSTALLATION AND OPERATING
INSTRUCTIONS, AND WARRANTY INFORMATION. ONE (1) ELECTRONIC PDF COPY OF O&M
MANUALS SHALL BE SUBMITTED TO THE A/E FOR REVIEW AT THE TIME OF SUBSTANTIAL
COMPLETION. PROVIDE ONE (1) HARD COPY AND ONE (1) ELECTRONIC PDF COPY OF THE FINAL
O&M MANUALS TO THE OWNER.
12. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING A SET OF AS-BUILT DRAWINGS ON
SITE WHICH INDICATE IN RED ALL DEVIATIONS FROM ORIGINAL CONSTRUCTION DOCUMENTS,
INCLUDING APPROVED CONSTRUCTION CHANGE ORDERS. AS-BUILT DRAWINGS SHALL BE
SUBMITTED TO THE A/E AT THE TIME OF SUBSTANTIAL COMPLETION. AS-BUILT DRAWINGS
SHALL BE CLEARLY LEGIBLE AND COMPLETE.
13. CONTRACTOR SHALL KEEP PUBLIC AREAS FREE OF TRASH AND CONSTRUCTION DEBRIS AND
CLEAN ENTIRE WORK AREA ON A DAILY BASIS.
14. TEMPORARY POWER AND WATER SERVICE ARE AVAILABLE ON SITE FOR THE CONTRACTOR'S
USE. CONTRACTOR SHALL COORDINATE ACCESS WITH OWNER AND SHALL PROVIDE ANY
REQUIRED TEMPORARY CONNECTIONS AND EXTENSIONS.
15. CONTRACTOR SHALL PROVIDE A TEMPORARY TOILET FACILITY FOR USE BY CONTRACTOR'S
PERSONNEL FOR THE DURATION OF THE PROJECT.
16. CONTRACTOR SHALL VISIT THE SITE TO BECOME FAMILIAR WITH THE SCOPE OF WORK AND TO
VERIFY EXISTING CONDITIONS PRIOR TO BIDDING THIS PROJECT. ANY DISCREPANCIES OR
AMBIGUOUS ITEMS MUST BE REPORTED TO THE A/E AND THE OWNER FOR CLARIFICATION
PRIOR TO BIDDING.
17. CONTRACTOR IS TYPICALLY PERMITTED TO WORK BETWEEN 7:00 AM AND 3:30 PM MONDAY
THRU FRIDAY. WORK OUTSIDE THESE HOURS SHALL BE COORDINATED WITH OWNER'S
PROJECT MANAGER DURING CONSTRUCTION. CONTRACTOR SHALL COORDINATE
CONSTRUCTION ACTIVITIES WITH OWNER FOR SPECIAL EVENTS.
18. CONTRACTOR SHALL PROTECT THE BUILDING, ADJACENT FEATURES, ROADWAYS, WALKWAYS, SITE IMPROVEMENTS, EXTERIOR PLANTINGS, LANDSCAPING, ETC AS REQUIRED FROM DAMAGE
AND CORRECT DAMAGE RESULTING FROM CONSTRUCTION ACTIVITIES TO THE SATISFACTION
OF THE OWNER.
19. CONTRACTOR SHALL COLLECT DEMOLISHED MATERIALS AND PLACE IN APPROPRIATE
DISPOSAL CONTAINERS. DEMOLISHED MATERIALS SHALL BE PROMPTLY REMOVED FROM THE
OWNER'S PROPERTY AND DISPOSED OF LEGALLY.
20. CONTRACTOR SHALL COORDINATE MATERIAL STORAGE AND DUMPSTER LOCATION WITH
OWNER DURING CONSTRUCTION.
21. CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SAFETY AND SECURITY FOR THE DURATION
OF THE PROJECT. CONTRACTOR SHALL PROVIDE ORANGE CONSTRUCTION FENCING AROUND
PERIMETER OF WORK AREA.
22. CONTRACTOR SHALL PROVIDE PRE-DEMOLITION PHOTOGRAPHIC OR VIDEOGRAPHIC
DOCUMENTATION TO SHOW EXISTING CONDITIONS OF FINISHED SURFACES IN WORK AREA AND
ADJOINING CONSTRUCTION INCLUDING SITE STORAGE AND ACCESS AREAS PRIOR TO
PRE-CONSTRUCTION MEETING AND A MINIMUM OF 10 WORKING DAYS PRIOR TO
COMMENCEMENT OF WORK.
23. CONTRACTOR SHALL NOTIFY OWNER OF ANY INTERRUPTION OF UTILITIES INCLUDING BUT NOT
LIMITED TO POWER, WATER, COMMUNICATIONS, ETC AND COORDINATE OUTAGE WITH OWNER.
24. ANY ROAD/PARKING LOT CLOSURE SHALL BE DONE IN ACCORDANCE WITH THE LATEST
VERSION OF THE VIRGINIA WORK AREA PROTECTION MANUAL.
25. DEFINITIONS:
FURNISH: SUPPLY AND DELIVER TO PROJECT SITE FOR INSTALLATION BY OTHERS.
INSTALL: INSTALL ITEMS FURNISHED BY OTHERS, INCLUDING UNLOADING, TEMPORARILY
STORING, UNPACKING, AND ASSEMBLY.
PROVIDE: FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE.
REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSE OF THEM
OFF-SITE UNLESS INDICATED TO BE REMOVED AND SALVAGED OR REMOVED AND REINSTALLED.
REMOVE AND REINSTALL: DETACH ITEMS FROM EXISTING CONSTRUCTION, PREPARE FOR
REUSE, AND REINSTALL WHERE INDICATED.
REMOVE AND SALVAGE: CAREFULLY DETACH FROM EXISTING CONSTRUCTION, IN A MANNER TO
PREVENT DAMAGE, AND DELIVER TO OWNER.
RT 3
RT 29
RT 15
RT
RT 3
RT
5B
RT 29B
AVE
FEDERAL ST
BLUE RIDGE
Lic. No. 048440
ANDREW S. KLEPAC WILLIAM L. ALLEN
Lic. No. 034677 Lic. No. 0402061572
JOSEPH R. GOSSEN
PHASING:
ENTRANCE WILL BE CLOSED FOR THE DURATION OF CONSTRUCTION. VDOT WILL PROVIDE CLOSURE AND ASSOCIATED WAYFINDING TO
ALTERNATE ENTRANCE AND TRAFFIC FLOW DURING CONSTRUCTION.
DELEGATED DESIGN SYSTEMS AND PRODUCTS:
1. THE GUARD HOUSE IS INCLUDED IN THIS PROJECT AS A DELEGATED DESIGN SYSTEM AND SHALL
COMPLY WITH THE LOAD CRITERIA INDICATED IN THE GENERAL NOTES ON DRAWING AS3 AND
SPECIFICATION SECTION 133423.16 - FABRICATED GUARD HOUSE.
NOTES:
1. IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT FROM COMPLIANCE BECAUSE THE NEW BUILDING
CONSTRUCTION IS NOT GREATER THAN 5,000 GROSS SQUARE FEET.
2. IN ACCORD WITH THE VIRGINIA ENERGY CONSERVATION CODE (VECC), THE BUILDING SHALL COMPLY WITH VECC SECTIONS C402
THROUGH C405 AND C408.SCALE:
NORTH
NONE
KEYPLAN - RESTROOM ACCESS
DISTRICT OFFICE
BUILDING 7000-003
WOMEN'S ROOMMEN'S ROOM
GUARD HOUSE
ORANGE RDBUS ROUTE 15
03/13/2026 03/13/2026 03/13/2026
IFB # 160775
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text H
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text H
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text H
AutoCAD SHX Text E
W
WV
WV
WV
S
S
S
D
D
D
UG E
UG E
UG T
UG T
UG T
UG T
U G
T U
G T
U G
T
UG
T
X
X
X
X
X
X
X X
X
X
OH E
OH E
OH E
OH E
OH E
OH E
OH E
OH E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
OH E
OH E
OH E
UG E
UG E
UG E
UG
E
JB
JB
JB
JB
O H
E
EP
UG E
U G
E U
G E
U G
E
UG E
UG
T
C
C
G
G
MM
GATE
GAT
E
C.
L.
F
EN
CE
C.
L.
F
EN
CE
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
12" TC
8" C
O N
4" CI
10" TC
8" PVC
8" PVC
6" P
VC (1)
(2)
(1)
(3)
(4)
(2)
A
B
C
D
SIGN
12" RCP 24" RCP
12" RCP
6" TC
6" T
C
12" R C
P
18" CM
P
18" C M
P
24" RCP
" C
M P
30" RCP
" R
C P
(b
15" RCP
24" RCP
INV OUT: 444.7'
INV IN: 448.4'
(SOURCES NOT FOUND)
END OF PIPE
NOT FOUND
INV IN: 448.8'
D
(a) (b)
(a)
(b)
15" RCP (a)
MIXED HARDWOODS
20" MAGNOLIA
20" CEDAR
20" CHERRY
18" CEDAR
GATE
SENSOR
GATE
SENSOR
DOOR
SENSOR
CONC. COLUMN (TYP)
MULTI-STORY
BRICK OFFICE BUILDING
+ 455.3'
+ 455.1'
+ 456.9'
+ 452.7' + 454.7'
+ 453.0'
+ 453.6'
+ 456.6' + 454.8'
+ 456.5'
+ 455.2'
+ 454.7'
+ 456.8'
+ 456.8'
+ 456.8'
+ 459.2'
+ 458.9'
+ 460.6'
±1
0' T
O G
ER
M
AN
N
A H
W Y
454 456
O R
AN
G
E R
D
BU
S.
R O
U
TE
REMOVE PAVEMENT
REMOVE PIPES AND INLETS
REMOVE FENCE
AND GATE
REMOVE TREE
REMOVE TREE
BENCHMARK:
CHISELED SQUARE SET
ON NORTHEAST CORNER
OF CURB INLET
ELEV: 455.02'
REMOVE TREE
4 4
ADA PARKING
TO REMAIN
A
SANITARY SCHEDULE
SANITARY MH
TOP: 459.1'
*COULD NOT OPEN
SANITARY MH
TOP: 456.0'
INV IN(1): 451.1'
INV IN(2): 449.8'
INV OUT: 449.5'
SANITARY MH
TOP: 451.7'
INV IN(1): 446.5'
INV IN(2): 444.0'
INV IN(3): 447.6'
INV IN(4): 445.5'
INV OUT: 443.8'
B
C
STORM SCHEDULE
GRATED D.I.
TOP: 455.1'
INV IN(a): 453.8' INV IN(b): 453.4'
INV OUT: 453.3'
CURB INLET
TOP: 455.2'
INV IN: 452.6'
INV OUT: 452.5'
GRATED D.I.
TOP: 453.2'
INV IN: 451.3'
INV OUT: 451.2'
STORM VAULT W/ MH
TOP: 452.3'
*UNABLE TO IDENTIFY PIPES
COMING INTO STRUCTURE
BOT. STR: 445.5'
GRATED D.I.
TOP: 451.9'
INV OUT: 449.4'
GRATED D.I.
TOP: 456.4'
INV OUT: 454.2'
GRATED D.I.
TOP: 455.8'
INV IN: 454.0'
INV OUT: 453.9'
STORM MANHOLE
TOP: 457.3'
*ANY INCOMING PIPES WERE
NOT MEASURED
INV OUT: 453.5'
PAVED OVER STRUCTURE
TOP (PAVEMENT): 452.5'
INV IN(a): 447.7' INV IN(b): UNABLE TO ACCESS
INV OUT: 446.6'
CURB INLET
TOP: 451.3'
INV IN(a): 448.5' INV IN(b): 448.4'
INV OUT: 448.2'
1" = 20'
20 10 20 40
GRAPHIC SCALE IN FEET
N O
R
TH
EXISTING CONDITIONS AND DEMOLITION PLAN
C1
REVISIONS DATEBYNO.
1"
Full Scale Verification
0"
ANDREW S. KLEPAC
Lic. No. 048440
3/13/2026
23135 2026-03-13
DATE:PROJECT NO:
VIRGINIA A&E, PLLC
1115 VISTA PARK DRIVE
FOREST, VIRGINIA 24551
PHONE: (434) 316-6001
Drawing No.:
ENGINEERING • SURVEYING • LAND DEVELOPMENT • ENVIRONMENTAL
GEOTECHNICAL • CONSTRUCTION TESTING & INSPECTION • CULTURAL RESOURCES
2524 LANGHORNE ROAD
LYNCHBURG VA 24501
HANDP.COM WEBSITE
434.847.7796 MAIN
434.847.0047 FAX
INSPIRED / RESPONSIVE / TRUSTED
VIRGINIA DEPARTMENT OF TRANSPORTATION
CULPEPER DISTRICT ENTRANCE
PROJECT CODE: 501-B4501-002
CULPEPER, VIRGINIA
SITE
SURVEY NOTES
1. THIS TOPOGRAPHIC SURVEY WAS COMPLETED UNDER THE DIRECT RESPONSIBLE
CHARGE OF JOHN E. HODNETT FROM AN ACTUAL GROUND SURVEY MADE UNDER MY
SUPERVISION; THE DATA WAS OBTAINED DECEMBER 21, 2023 AND THIS PLAT MEETS
MINIMUM ACCURACY STANDARDS UNLESS OTHERWISE NOTED.
2. THIS PLAT HAS BEEN PREPARED WITHOUT THE BENEFIT OF A TITLE REPORT AND
DOES NOT, THEREFORE, NECESSARILY INDICATE ALL ENCUMBRANCES ON THE
PROPERTY.
3. THE AREA SHOWN HERON IS LOCATED IN FLOOD HAZARD ZONE 'X' AND IS NOT
LOCATED WITHIN FLOOD HAZARD ZONE 'A' FOR A 100 YEAR FLOOD AS DETERMINED
BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY AS SHOWN ON
COMMUNITY-PANEL MAP #51047C0230D DATED FEBRUARY 26, 2021 (REVISED).
4. HORIZONTAL CONTROL FOR THIS PROJECT IS BASED ON VIRGINIA STATE PLANE GRID
NORTH ZONE (NAD 83). VERTICAL CONTROL FOR THIS PROJECT IS BASED ON NAVD
88, GEOID MODEL 18B.
5. THE UTILITIES SHOWN HERON ARE BASED ON PAINTED MARKS PROVIDED BY VDOT
AND VISIBLE EVIDENCE IN THE FIELD. THIS SURVEY CANNOT GUARANTEE THAT ALL
UTILITIES WITHIN THE PROJECT AREA ARE SHOWN. IT SHALL BE THE RESPONSIBILITY
OF THE OWNER/CONTRACTOR TO HAVE UNDERGROUND UTILITIES MARKED PRIOR TO
EXCAVATION/LAND DISTURBANCE OF ANY KIND.
6. THIS SURVEY WAS PREPARED AT THE REQUEST OF THE VIRGINIA DEPARTMENT OF
TRANSPORTATION.
7. UNDERGROUND STORM LINES IN STRUCTURES 4 AND 9 ARE SHOWN APPROXIMATE
BASED ON FIELD EVIDENCE. ANY PROPOSED WORK ON THESE STRUCTURES SHOULD
BE FIELD VERIFIED.
BENCHMARK
SS
UG T
UG STORM DRAIN
UG SANITARY SEWER LINE
UG TELECOM LINE
EDGE OF PAVEMENT
SIGN
LIGHT POLE
UTILITY POLE
GUY WIRE
GATE MOTOR
WATER VALVEWV
SURVEY LEGEND
FENCEXX
CONCRETE
TREE
EDGE OF WOODS
BOLLARD POST
COMMUNICATIONS PEDESTAL
UTILITY JUNCTION BOX W UG WATER LINE
UG E UG ELECTRIC LINE
RIPRAP LINED DITCH
SHRUB
D
S
STORM MANHOLE
GRATED STORM INLET
SANITARY MANHOLE
JB
C
G
OH E OH ELECTRIC LINE
THE ENGINEER AND/OR SURVEYOR TAKES NO RESPONSIBILITY FOR THE
LOCATION OR ACCURACY OF THE UTILITIES AS SHOWN HEREON OR ANY
UTILITIES WITHIN THE PROJECT THAT MAY NOT BE SHOWN HEREON. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING THE UTILITY
COMPANIES TO SEE IF ANY UTILITIES EXIST WITHIN THE AREA OF THE
PROJECT BEFORE ANY CONSTRUCTION BEGINS. ANY COST INCURRED BY
DAMAGING ANY UTILITY WITHIN THE PROJECT SHALL BE AT THE EXPENSE
OF THE CONTRACTOR.
NO LESS THAN 72 WORKING HOURS PRIOR TO EXCAVATION, THE
CONTRACTOR SHALL CONTACT VIRGINIA 811 (MISS UTILITY) AND ADVISE
THE NATURE AND LOCATION OF THE WORK. SOIL SHALL NOT BE
DISTURBED UNTIL THE DIG TICKET HAS BEEN PROCESSED.
THIS DRAWING IS INTENDED
TO BE PLOTTED IN COLOR.
DEMOLITION KEY NOTES
VDOT WILL CLOSE ORANGE ROAD ENTRANCE AND PROVIDE WAYFINDING TO ALTERNATE
ENTRANCE OFF STANDPIPE ROAD FOR THE DURATION OF CONSTRUCTION.
VDOT WILL CLOSE EXISTING PARKING LOT OFF FROM THE WORK AREA AND PROVIDE
SIGNAGE FOR PARKING LOT ACCESS AND USAGE FROM ALTERNATE ENTRANCE.
REMOVE SIGN AND ASSOCIATED POST.
REMOVE SIGN POST.
REMOVE CARD READER AND ASSOCIATED BOLLARD PROTECTION.
REMOVE PIPE BOLLARD.
CONTRACTOR TO COORDINATE RELOCATE OF KNOX MEDVAULT. CONTRACTOR TO RETAIN
ASSOCIATED ENCLOSURE AND SUPPORTS. REMOVE ASSOCIATED BRANCH CIRCUIT.
TEMPORARILY RELOCATE MAILBOXES TO BE OUTSIDE THE ORANGE ROAD ENTRANCE
CLOSURE. COORDINATE MAILBOX LOCATION WITH VDOT.
REMOVE SLIDING GATE OPERATOR AND ASSOCIATED POWER AND COMMUNICATIONS.
REMOVE FIXTURE, CONCRETE COLUMN, BRANCH CIRCUIT, AND ASSOCIATED HANDHOLES.
REMOVE CONCRETE PIER, BRANCH CIRCUIT, POLE, AND LIGHT FIXTURE(S). FURNISH
LIGHT FIXTURES TO OWNER.
CONFIRM HANDHOLE IS ASSOCIATED WITH GATE OPERATOR OR OTHER BRANCH CIRCUIT
THAT IS REMOVED BY THIS PROJECT. REMOVE HANDHOLE AND BRANCH CIRCUITRY.
REMOVE UP TO (4) PLANTINGS TO PREPARE FOR DUCT BANK INSTALLATION. FIELD
COORDINATE WITH OWNER REGARDING WHICH PLANTS TO REMOVE.
IFB # 160775
UG E
U G
C U
G C
U G
E U
G E
UG C
UG C
UG C
UG E
UG E
UG E
UG C
U G
C U
G C
U G
C
UG E
U G
E U
G E
U G
E
UG E
UG
E
UG
E
UG C
UG C
UG C
UG C
UG C
UG C
UG
C
UG E
UG E
UG
E
UG C
UG C
UG C
UG E
UG E
UG
E
UG
C
UG
C
UG C
UG C
W
WV
WV
WV
S
S
S
D
D
UG E
UG E
UG T
U G
T U
G T
U G
T
UG
T
X
X
X
X
X
X
X
OH E
OH E
OH E
OH E
OH E
OH E
OH E
OH E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
OH E
OH E
OH E
UG
E
JB
O H
E
EP
UG
T
C
C
G
GAT
E
C.
L.
F
EN
CE
C.
L.
F
EN
CE
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
12" TC
8" C
O N
4" CI
10" TC
8" PVC
8" PVC
6" P
VC (1)
(2)
(1)
(3)
(4)
(2)
A
B
C
D
12" RCP 24" RCP
12" RCP
6" TC
6" T
C
18" C M
P
24" RCP
" C
M P
30" RCP
" R
C P
(b
15" RCP
24" RCP
INV OUT: 444.7'
INV IN: 448.4'
INV IN: 448.8'
D
(a) (b)
(a)
(b)
15" RCP (a)
MIXED HARDWOODS
20" CHERRY
GATE
SENSOR
DOOR
SENSOR
MULTI-STORY
BRICK OFFICE BUILDING
+ 455.3'
+ 455.1'
+ 456.9'
+ 452.7' + 454.7'
+ 453.0'
+ 453.6'
+ 456.6' + 454.8'
+ 456.5'
+ 455.2'
+ 454.7'
+ 456.8'
+ 456.8'
+ 456.8'
+ 459.2'
+ 458.9'
+ 460.6'
±1
0' T
O G
ER
M
AN
N
A H
W Y
454 456
GUARD HOUSE
F.F.=456.90
O R
AN
G
E R
D
BU
S.
R O
U
TE
458.10 P=MG
455.70 P
456.30 P=SW
455.80 TC
455.30 P
457.70 P=MG
456.10 P
458.30 TC
457.80 P
456.60 TC
456.10 P
456.50 TC
456.00 P
456.40 TC
455.90 P
456.40 TC
455.90 P
454.90 TC
454.40 P
456.80 SW
456.60 SW
456.40 SW
456.40 SW
456.00 SW
455.40 P=SW
456.00 P
455.10 TC
454.60 P
453.70 TC
453.20 P
456.80 SW
458.50 SW
456.55 SW
458.70 P=MG
455.70 TC
455.20 P
455.65 P
UG E
U G
C U
G C
U G
E U
G E
UG C
UG C
UG C
UG E
UG E
UG E
UG C
U G
C U
G C
U G
C
UG E
U G
E U
G E
U G
E
UG E
UG
E
UG
E
UG C
UG C
UG C
UG C
UG C
UG C
UG
C
UG E
UG E
UG
E
UG C
UG C
UG C
UG E
UG E
UG
E
UG
C
UG
C
UG C
UG C
W
WV
WV
WV
S
S
S
D
D
UG E
UG E
UG T
U G
T U
G T
U G
T
UG
T
X
X
X
X
X
X
X
OH E
OH E
OH E
OH E
OH E
OH E
OH E
OH E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
O H
E
OH E
OH E
OH E
UG
E
JB
O H
E
EP
UG
T
C
C
G
GAT
E
C.
L.
F
EN
CE
C.
L.
F
EN
CE
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
12" TC
8" C
O N
4" CI
10" TC
8" PVC
8" PVC
6" P
VC (1)
(2)
(1)
(3)
(4)
(2)
A
B
C
D
12" RCP 24" RCP
12" RCP
6" TC
6" T
C
18" C M
P
24" RCP
" C
M P
30" RCP
" R
C P
(b
15" RCP
24" RCP
INV OUT: 444.7'
INV IN: 448.4'
INV IN: 448.8'
D
(a) (b)
(a)
(b)
15" RCP (a)
MIXED HARDWOODS
20" CHERRY
GATE
SENSOR
DOOR
SENSOR
MULTI-STORY
BRICK OFFICE BUILDING
±1
0' T
O G
ER
M
AN
N
A H
W Y
KEEP EXISTING
SLIDING GATE
GUARD HOUSE
F.F.=456.90
O R
AN
G
E R
D
BU
S.
R O
U
TE
VDOT STD. CG-2
16'
28'
12'
12'
5' SIDEWALK (TYP)
VDOT STD. CG-6
4'
AUTOMATIC
SLIDING GATE
34' OPENING BARRIER GATE (TYP)
ACCESS CONTROL
INTERCOM
COORDINATE PAVEMENT AND
SIDEWALK WITH PROPOSED
IMPROVEMENTS TO ORANGE ROAD
BOLLARD (TYP)
VDOT STD. CG-2
CHAIN LINK FENCE
VDOT STD. CG-2 R30'
R100'
R18'
R6' R20'
R7'
R3'
VDOT STD. CG-12 TYPE B
VDOT STD. CG-12 TYPE B
FUTURE SIDEWALK
EXTENSION TO BE
BY VDOT
VDOT STD. CG-12 TYPE B
BADGE READER (TYP)
ADJUST VALVE TO
MATCH FINISH GRADE
STORM STRUCTURE SCHEDULE
VDOT STD. DI-7 (GRATE B)
TOP=455.10
INV IN=453.80 (EX. 6")
INV IN=453.40 (EX. 6")
INV OUT=452.30
STORM SEWER SCHEDULE
89 LF OF 18" CL III RCP @ 1.1%
INV IN=452.30; INV OUT=451.3013
SITE AND GRADING PLAN
C2
REVISIONS DATEBYNO.
1"
Full Scale Verification
0"
ANDREW S. KLEPAC
Lic. No. 048440
3/13/2026
23135 2026-03-13
DATE:PROJECT NO:
VIRGINIA A&E, PLLC
1115 VISTA PARK DRIVE
FOREST, VIRGINIA 24551
PHONE: (434) 316-6001
Drawing No.:
ENGINEERING • SURVEYING • LAND DEVELOPMENT • ENVIRONMENTAL
GEOTECHNICAL • CONSTRUCTION TESTING & INSPECTION • CULTURAL RESOURCES
2524 LANGHORNE ROAD
LYNCHBURG VA 24501
HANDP.COM WEBSITE
434.847.7796 MAIN
434.847.0047 FAX
INSPIRED / RESPONSIVE / TRUSTED
VIRGINIA DEPARTMENT OF TRANSPORTATION
CULPEPER DISTRICT ENTRANCE
PROJECT CODE: 501-B4501-002
CULPEPER, VIRGINIA
SITE
CONTOUR456
CONCRETE
PROPOSED LEGEND
FF FINISHED FLOOR
P PAVEMENT
TC TOP OF CURB
STORM SEWER
CHAIN LINK FENCE
NEW ASPHALT PAVEMENT
2" SM-9.5A MILL AND OVERLAY
STORM SEWER INLET
UG E UNDERGROUND ELECTRIC
UG C UNDERGROUND COMMUNICATIONS
SITE AND GRADING NOTES
1. ANY CHANGES TO THE PLANS MUST BE APPROVED BY THE ENGINEER PRIOR TO CONSTRUCTION.
2. CONTRACTOR TO FIELD VERIFY ALL INVERTS AND CONNECTION POINTS PRIOR TO
COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES. IF POTENTIAL CONFLICTS ARE DETECTED, CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY.
3. SEE MEP PLANS FOR PROPOSED SITE ELECTRICAL AND COMMUNICATIONS IMPROVEMENTS.
4. PROPOSED FENCING SHALL COMPLY WITH VDOT STD. FE-CL AND R&B SPEC SECTION 242.
FENCING SHALL BE 6' TALL VINYL-COATED CHAIN LINK.
5. PAVEMENT MARKINGS ARE TO BE BY VDOT. DIRECTIONAL ARROWS WILL BE INSTALLED BY VDOT
ONCE OPERATIONAL FLOW PATTERNS ARE CONFIRMED BY VDOT.
6. ALL FILL SHALL BE COMPACTED TO MINIMUM 95% STANDARD PROCTOR. ALL FILL SHALL BE
PLACED IN 8" LOOSE LIFTS.
7. ALL FILL AREAS TO BE STRIPPED OF UNSUITABLE MATERIAL BEFORE PLACING AND COMPACTING
FILL MATERIAL.
8. PROVIDE PERMANENT SEEDING AND MULCHING IN ALL DISTURBED AREAS NOT OTHERWISE
STABILIZED. PLACE A MINIMUM OF 4" OF TOPSOIL IN AREAS TO BE SEEDED. IN AREAS OF
EXISTING PAVEMENT THAT WILL BE SEEDED, THE FULL DEPTH OF PAVEMENT AND STONE SHALL
BE REMOVED, AND THE UNDERLYING SUBGRADE SCARIFIED PRIOR TO TOPSOIL PLACEMENT.
9. CONTRACTOR RESPONSIBLE FOR OBTAINING AN APPROVED E&S PLAN FOR ALL OFFSITE WASTE
OR BORROW AREAS IF NEEDED.
10. ALL STORM PIPE IS TO BE INSTALLED PER VDOT STANDARD PB-1. PIPE MATERIAL SHALL
CONFORM TO VDOT SPECIFICATION SECTION 232.
11. ALL STORM PIPE IS TO BE INSTALLED WITH SILT-TIGHT JOINTS UNLESS NOTED OTHERWISE.
12. PROVIDE INLET PROTECTION ON ALL STORM INLETS PER VDOT STD. EC-6. ADDITIONAL ESC
MEASURES MAY BE REQUIRED BY INSPECTION ENGINEER IF WARRANTED BY THE FIELD
CONDITIONS.
13. ALL STORM SEWER STRUCTURES TO HAVE INVERT SHAPING PER VDOT STD. IS-1.
1" = 20'
20 10 20 40
GRAPHIC SCALE IN FEET
N O
R
TH
SITE PLAN GRADING PLAN
THIS DRAWING IS INTENDED
TO BE PLOTTED IN COLOR.
DETAILS
C3
REVISIONS DATEBYNO.
1"
Full Scale Verification
0"
ANDREW S. KLEPAC
Lic. No. 048440
3/13/2026
23135 2026-03-13
DATE:PROJECT NO:
VIRGINIA A&E, PLLC
1115 VISTA PARK DRIVE
FOREST, VIRGINIA 24551
PHONE: (434) 316-6001
Drawing No.:
ENGINEERING • SURVEYING • LAND DEVELOPMENT • ENVIRONMENTAL
GEOTECHNICAL • CONSTRUCTION TESTING & INSPECTION • CULTURAL RESOURCES
2524 LANGHORNE ROAD
LYNCHBURG VA 24501
HANDP.COM WEBSITE
434.847.7796 MAIN
434.847.0047 FAX
INSPIRED / RESPONSIVE / TRUSTED
VIRGINIA DEPARTMENT OF TRANSPORTATION
CULPEPER DISTRICT ENTRANCE
PROJECT CODE: 501-B4501-002
CULPEPER, VIRGINIA
SITE
ASPHALT PAVEMENT
N.T.S.
8" VDOT #21B STONECOMPACTED SUBGRADE
2" VDOT SM-9.5A
NOTE: APPLICATION OF TACK AT JOINTS,
ADJACENT TO CURBS, GUTTERS OR OTHER
APPURTENANCES SHALL BE APPLIED BY
HAND WAND AT THE RATE OF 0.2 GAL./SQ.YD.
CRS-1 @ 0.05 GAL/SY
4" VDOT BM-25.0
CONCRETE SIDEWALK
N.T.S.
CONCRETE TO BE POURED IN ACCORDANCE WITH VDOT SPEC.
SECTION 316 WITH A WOOD FLOAT FINISH. CONSTRUCTION
JOINTS TO BE AT 6' INTERVALS, ISOLATION JOINTS TO BE AT
30' INTERVALS FILLED W/ PRE-MOLDED 1/2" JOINT FILLER.
4" CONCRETE: 3,500 PSI
NON-STRUCTURAL
CONCRETE, EXPOSURE
CLASS F3, AIR-ENTRAINED.
6" VDOT #21B STONE
#6 X 6' X 6"
WOVEN WIRE
COMPACTED SUBGRADE
SLOPE TO DRAIN
PER PLAN12" (TYP)
METALLIC
LOCATING WIRE
(TYP FOR ALL
INSTALLATIONS)
X
X
X
X
X
X
X
SCALE:
NORTH
10'5'0 20' 1"=10'-0"
ENLARGED SITE PLAN
GUARD HOUSE,
SEE DRAWING AS2
BARRIER ARM,
SEE DETAILS,
THIS DRAWING,
TYPICAL OF (2)
6" C
LR,
MIN
1'-6" C
LR,
MIN
GUARD HOUSE,
FOUNDATION PAD
SLIDING GATE
OPERATOR
AS1 AS1
BOLLARD,
TYP OF (7)
CONC
ISLAND
ACCESS CONTROL
FOR CARD READER
TO OPEN GATE FOR
PEDESTRIANS AFTER
HOURS
ACCESS CONTROL &
INTERCOM PEDESTAL,
SEE DETAIL, DWG E5,
TYP OF (3)
NOTES:
1. WHERE FOOTING IS NOT TOPPED
BY CONCRETE ISLAND OR
SIDEWALK, RAISE TOP OF
FOOTING TO GRADE, BROOM
FINISH TOP, AND CHAMFER
CORNERS.
2. FOR FOUNDATIONS IN
CONCRETE ISLAND, SEE
SECTION 1, THIS DRAWING.
1'-6"Ø
OR GRADE
SCALE:
3"0 6" 1' 2'
1"=1'-0"
BOLLARD DETAIL
SCALE:
3"0 6" 1' 2'
1"=1'-0"
BARRIER ARM FOUNDATION DETAIL
2'-0"Ø
1'-3"±
COAT BOLLARD
W/MASTIC OR 1/16"
BUTYL RUBBER TAPE
BELOW T/CONC
2' -6
4'
-0
1"
PLASTIC COVERED 6"Ø
SCHEDULE 40 GALVANIZED
STEEL BOLLARD FILLED
W/CONCRETE
PLASTIC COVER EXTENDS
TO TOP OF SLAB
1/2" ISOLATION JOINT
W/JOINT FILLER
6"
T/CONCRETE
SEE PLAN
T/CONCRETE ACCESS CONTROL &
INTERCOM PEDESTAL
T/FOOTING
8"
2' -6
ANCHOR BOLTS PER
MANUFACTURER
SCALE:
3"0 6" 1' 2'
1"=1'-0"
ACCESS CONTROL AND INTERCOM PEDESTAL FOUNDATION DETAIL
1'-6"Ø
2' -6
ANCHOR BOLTS PER
MANUFACTURER
NOTES:
1. FOR FOUNDATIONS IN
CONCRETE ISLAND,
SEE SECTION 1, THIS
DRAWING
T/FOOTING
THICKEN CONCRETE
SIDEWALK AS NEEDED
TO ENCASE BOLLARD
NOTES:
1. WHERE FOOTING IS NOT TOPPED
BY CONCRETE ISLAND OR
SIDEWALK, RAISE TOP OF
FOOTING TO GRADE, BROOM
FINISH TOP, AND CHAMFER
CORNERS.
8" M
IN
EM
BE
D
8" M
IN
EM
BE
D
16'-0"
EQ EQ
1'-6" 1'-6" 1'-6" 2'-0"
8"
3" CLR, MIN
8"
3" CLR, MIN
2' -0
2' -0
1/
2" C
LR
M
IN
1/
2" C
LR
M
IN
BOLLARD
ACCESS CONTROL &
INTERCOM PEDESTAL
BOLLARD
BARRIER ARM
ASPHALTASPHALT
8" 6"
8"
8"
#4@12"
EACH WAY,
SEE BOLLARD,
THIS DRAWING
SEE BOLLARD,
THIS DRAWING
TYPICAL
MATCH PROFILE OF
VDOT CG-2 CURB
SCALE:
6"0 1' 2' 5'
1/2"=1'-0"
SECTION1
AS1 AS1
ANCHOR BOLTS PER
MANUFACTURER
ANCHOR BOLTS PER
MANUFACTURER
6" M
IN
EM
BE
D
6" M
IN
EM
BE
D
VIRGINIA DEPARTMENT OF TRANSPORTATION
CULPEPER DISTRICT ENTRANCE
PROJECT CODE: 501-B4501-002
CULPEPER, VIRGINIA
23135 2026-03-13
DATE:PROJECT NO:
VIRGINIA A&E, PLLC
1115 VISTA PARK DRIVE
FOREST, VIRGINIA 24551
PHONE: (434) 316-6001
Drawing No.:
1"
Full Scale Verification
0"
REVISIONS DATEBYNO.
CONSTRUCTION NOTES:
1. COORDINATE BARRIER ARM CABINET ACCESS DOOR AND BOLLARD LOCATION TO
PROVIDE UNOBSTRUCTED ACCESS TO CABINET.
2. WHERE BOLLARD FOUNDATION CONFLICTS WITH VDOT CG-2 CURB OR ISLAND
TURNDOWN, CAST CURB AROUND BOLLARD FOUNDATION.
XX
ENLARGED SITE PLAN
AND DETAILS
AS1
AMSL ABOVE MEAN SEA LEVEL
ARCH ARCHITECTURAL
B/ BOTTOM OF
BD BAR DIAMETER
BOT BOTTOM
BP BASE PLATE
℄ CENTERLINE
CJ CONTROL / CONSTRUCTION JOINT
CLR CLEAR
CONC CONCRETE
CMU CONCRETE MASONRY UNIT
CONT CONTINUOUS
Ø DIAMETER
DIM DIMENSION
DS DOWNSPOUT
DWG DRAWING
(E) EXISTING
EQ EQUAL
FF FINISHED FLOOR
FS FOOTING STEP
GA GAUGE
GALV GALVANIZED
LOC LOCATION
MAX MAXIMUM
MIN MINIMUM
OC ON CENTER
OD OUTSIDE DIAMETER
PSF POUNDS PER SQUARE FOOT
R RISER
REINF REINFORCEMENT
SEC SECTION
SIM SIMILAR
T TREAD
T/ TOP OF
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
WWF WELDED WIRE FABRIC
W/ WITH
ABBREVIATIONS:
WILLIAM L. ALLEN
Lic. No. 034677
03/13/2026
IFB # 160775
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text T
H
SCALE:
NORTH
6"0 1' 2' 5' 1/2"=1'-0"
GUARD HOUSE PLAN
8'-0"
8' -0
GUARD HOUSE
SCALE:
NORTH
6"0 1' 2' 5' 1/2"=1'-0"
FOUNDATION PLAN
10'-0"
'-0
NOTES:
1. EXTERIOR DIMENSIONS TO BE VERIFIED
WITH GUARD HOUSE MANUFACTURER.
8"
8"
TYP
TY
P
AS2 AS2
SCALE:
6"0 1' 2' 5'
1/2"=1'-0"
ELEVATIONA
AS2 AS2
6" CONCRETE SLAB
OVER VAPOR
BARRIER OVER 6"
COMPACTED 21A
STONE BASE.
REINFORCE WITH
WWF6x6-W2.9xW2.9.
B
AS2 AS2
SCALE:
6"0 1' 2' 5'
1/2"=1'-0"
ELEVATIONB
AS2 AS2
A
AS2 AS2
PRECAST CONCRETE
SPLASH BLOCK
DS
PRECAST CONCRETE
SPLASH BLOCK
DS
MIN
M
IN
9"
9"
(4) 1/2"Ø ASTM F1554,
GRADE 36 THREADED ROD
W/HILTI HIT-HY200 V3
ADHESIVE; EMBED 4" MIN.
LOCATE AS REQUIRED BY
GUARD HOUSE
MANUFACTURER
T/CONC SLAB
(456.60')
T/FINISHED FLOOR
(456.90')
T/CONC SLAB
(456.60')
T/FINISHED FLOOR
(456.90')
DS
SPLASH BLOCK
DS
SPLASH BLOCK
WORK COUNTER
AS2 AS2
T/ROOF
(465.27')
T/ROOF
(465.27')
2'-0"
MAXIMUM
2' -0
8"
T/CONC SLAB
EXTERIOR FACE OF
GUARD HOUSE
SCALE:
0 3'1'6" 2'
3/4"=1'-0"
SECTION1
AS2 AS2
3/4" CHAMFER WHERE
ADJACENT TO SOIL;
ISOLATION JOINT WHERE
ADJACENT TO CONCRETE
SE
E
PL
AN
#4 BAR, CONT
SCALE:
0 3'1'6" 2'
3/4"=1'-0"
SECTION2
AS2 AS2
4"
7' -6
3' -0
4'
-6
2' -8
WINDOW FRAME
COUNTER
STORAGE DRAWER
INNER PANEL
INSULATION
BRICK PANEL
FLOORBASE FRAMING
2" GROMMET FOR
ELECTRICAL &
COMMUNICATIONS
ACCESS AT EACH
CORNER BEHIND
DRAWER
ROOF, FASCIA,
& CEILING
THERMAL SAFETY
GLAZING
INSULATION
INSULATION
M
IN
IM
U
M
(EACH END OF
COUNTER)
1' -0
2'-6"
SCALE:
1'6"3"0 9"
1 1/2"=1'-0"
CONCRETE SPLASH BLOCK
4"
2"
NOTES:
1. INSTALL DOWNSPOUT BASE AND SPLASH BLOCK FOR POSITIVE
DRAINAGE AWAY FROM BUILDING.
DOWNSPOUT BASE
VIRGINIA DEPARTMENT OF TRANSPORTATION
CULPEPER DISTRICT ENTRANCE
PROJECT CODE: 501-B4501-002
CULPEPER, VIRGINIA
23135 2026-03-13
DATE:PROJECT NO:
VIRGINIA A&E, PLLC
1115 VISTA PARK DRIVE
FOREST, VIRGINIA 24551
PHONE: (434) 316-6001
Drawing No.:
1"
Full Scale Verification
0"
REVISIONS DATEBYNO.
GUARD HOUSE PLANS,
ELEVATION, AND DETAILS
AS2
WILLIAM L. ALLEN
Lic. No. 034677
03/13/2026
IFB # 160775
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text T
VIRGINIA DEPARTMENT OF TRANSPORTATION
CULPEPER DISTRICT ENTRANCE
PROJECT CODE: 501-B4501-002
CULPEPER, VIRGINIA
23135 2026-03-13
DATE:PROJECT NO:
VIRGINIA A&E, PLLC
1115 VISTA PARK DRIVE
FOREST, VIRGINIA 24551
PHONE: (434) 316-6001
Drawing No.:
1"
Full Scale Verification
0"
REVISIONS DATEBYNO.
GENERAL NOTES:
GENERAL:
1. GOVERNING BUILDING CODE:
2021 VIRGINIA UNIFORM STATEWIDE BUILDING CODE
2. MINIMUM DESIGN SUPERIMPOSED LOAD CRITERIA: FOR FLAT ROOFS AND ROOFS WITH A SLOPE OF LESS THAN FOUR (4) INCHES PER FOOT, ACTUAL DESIGN LOADS SHALL BE CALCULATED FOR LIVE LOAD, SNOW LOAD, ICE, WATER AND COMBINATIONS OF THESE LOADS, BUT SHALL BE NO LESS THAN
THE MINIMUM SUPERIMPOSED LOAD PER CPSM 6.1.4.1.: 30 PSF
3. FLOOR LIVE LOADS:
FLOOR LIVE LOAD, UNIFORM: 100 PSF, UON
FLOOR LIVE LOAD, CONCENTRATED: 2,000 LBS, UON
4. ROOF LIVE LOAD:
ROOF LIVE LOAD: 20 PSF
5. WIND LOAD CRITERIA:
ULTIMATE DESIGN WIND SPEED (3-SEC GUST): 111 MPH
NOMINAL DESIGN WIND SPEED: 85.98 MPH
BUILDING RISK CATEGORY: II
WIND EXPOSURE CONDITION: C
INTERNAL PRESSURE COEFFICIENT (GCPI): 0.18 +/-
6. SNOW LOAD CRITERIA:
GROUND SNOW LOAD (PG): 59.0 PSF
FLAT ROOF SNOW LOAD (PF): 41.3 PSF
SNOW EXPOSURE FACTOR (CE): 1.00
SNOW THERMAL FACTOR (CT): 1.00
7. RAIN LOAD CRITERIA:
RAIN INTENSITY (I): 5.98 IN/HR
8. SEISMIC LOAD CRITERIA:
BUILDING RISK CATEGORY: II
SEISMIC IMPORTANCE FACTOR (IE): 1.0
MAPPED SPECTRAL RESPONSE COEFFICIENT, (SS): 0.19
MAPPED SPECTRAL RESPONSE COEFFICIENT, (S1): 0.05
SITE CLASS (ASSUMED): D
SPECTRAL RESPONSE COEFFICIENT, (SDS): 0.150
SPECTRAL RESPONSE COEFFICIENT, (SD1): 0.070
SEISMIC DESIGN CATEGORY: B
SEISMIC FORCE RESISTING SYSTEM: TO BE DETERMINED BY GUARD HOUSE
MANUFACTURER
DESIGN BASE SHEAR: TO BE DETERMINED BY GUARD HOUSE
MANUFACTURER
SEISMIC RESPONSE COEFFICIENT, (CS): TO BE DETERMINED BY GUARD HOUSE
MANUFACTURER
RESPONSE MODIFICATION FACTOR (R): TO BE DETERMINED BY GUARD HOUSE
MANUFACTURER
ANALYSIS PROCEDURE USED: TO BE DETERMINED BY GUARD HOUSE
MANUFACTURER
9. CONTRACT DRAWINGS SHALL NOT BE MARKED AND SUBMITTED AS SHOP DRAWINGS.
10. THE CONTRACTOR SHALL VERIFY ALL EXISTING FIELD CONDITIONS, DIMENSIONS, AND ELEVATIONS
BEFORE PROCEEDING WITH CONSTRUCTION.
11. THE CONTRACTOR SHALL LOCATE ALL EXISTING UNDERGROUND UTILITIES AND PROTECT FROM
DAMAGE DURING EXCAVATION AND BACKFILLING OPERATIONS.
12. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND MATERIAL CERTIFICATIONS FOR REVIEW FOR THE FOLLOWING ITEMS. DO NOT FABRICATE MATERIALS UNTIL SUBMITTALS HAVE BEEN REVIEWED AND ALL
EXCEPTIONS HAVE BEEN RESOLVED.
A. CONCRETE MIX DESIGNS, TESTS, AND CERTIFICATES PER ACI 301
B. CONCRETE REINFORCING STEEL SHOP DRAWINGS
C. REBAR AND WWF PRODUCT DATA
D. ISOLATION JOINT MATERIAL
E. JOINT FILLER
F. VAPOR RETARDER PRODUCT DATA
G. ADHESIVE ANCHORS PRODUCT DATA
14. THE FOLLOWING SHALL BE TESTED BY AN INDEPENDENT TESTING AND INSPECTION FIRM PROVIDED BY THE OWNER. TEST FIRM SHALL REPORT FAILS IMMEDIATELY TO THE ARCHITECT/STRUCTURAL ENGINEER OF RECORD AND OWNER. TEST FIRM SHALL PROVIDE WRITTEN REPORTS FOR REVIEW BY
THE ARCHITECT/STRUCTURAL ENGINEER OF RECORD AND OWNER WITHIN 48 HOURS OF TESTING
COMPLETION INCLUDING:
A. BEARING AT BOTTOM OF FOOTING EXCAVATIONS
B. COMPACTION OF FILL MATERIALS
C. REINFORCEMENT PLACEMENT
D. CONCRETE COMPRESSIVE STRENGTH
E. CONCRETE SLUMP
F. CONCRETE AIR CONTENT
G. CONCRETE TEMPERATURE
H. CONCRETE PLACEMENT
I. CONCRETE CURING PROCEDURES AND MAINTENANCE OF CONCRETE TEMPERATURE
J. ANCHORS CAST IN CONCRETE
FOUNDATIONS:
1. DESIGN SOIL BEARING CAPACITY: 1500 PSF (ASSUMED)
2. WHERE FOOTING OR SLAB ON GRADE IS TO BE PLACED ON FILL, ALL TOPSOIL, ROOTS, TRASH, AND OTHER EXTRANEOUS MATERIALS SHALL BE REMOVED AND REPLACED WITH SELECT FILL COMPACTED TO A MINIMUM OF 98% OF ITS MAXIMUM DENSITY AT ITS OPTIMUM MOISTURE CONTENT AS MEASURED BY THE STANDARD PROCTOR METHOD (ASTM D698). THE TOP 12" SHALL BE COMPACTED TO A MINIMUM DENSITY OF 98%. EACH LAYER OF FILL SHALL BE NO GREATER THAN 6" THICK AND SHALL BE
COMPACTED AS SPECIFIED PRIOR TO PLACEMENT OF THE FOLLOWING LAYER.
3. OWNER SHALL ENGAGE A TESTING AND INSPECTION FIRM WITH A QUALIFIED GEOTECHNICAL ENGINEER LICENSED IN THE COMMONWEALTH OF VIRGINIA TO INSPECT AND APPROVE THE SUBGRADE INCLUDING FILL AND BACKFILL MATERIALS AND OPERATIONS. ALL FOUNDATION BEARING STRATA SHALL BE INSPECTED AND APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO ANY CONCRETE PLACEMENT. IF UNSUITABLE SOILS ARE ENCOUNTERED, THE GEOTECHNICAL ENGINEER AND THE
STRUCTURAL ENGINEER OF RECORD SHALL DETERMINE THE MEANS OF CORRECTIVE ACTION
INCLUDING, BUT NOT LIMITED TO, ITEMS NOTED BELOW:
A. FOOTING BEARING ELEVATIONS MAY BE LOWERED WHERE REQUIRED TO OBTAIN THE DESIGN SOIL
BEARING CAPACITY SPECIFIED ABOVE.
B. FOOTINGS MAY BE UNDERCUT AND BACKFILLED WITH COMPACTED STONE OR INCREASED IN
THICKNESS AS REQUIRED TO OBTAIN THE DESIGN SOIL BEARING CAPACITY NOTED ABOVE.
4. FOOTING EXCAVATIONS SHALL NOT BE LEFT OPEN OVER NIGHT WHEN RAIN IS FORECAST. OPEN EXCAVATIONS LEFT EXPOSED TO RAIN, SNOW, OR ICE SHALL HAVE A LAYER OF 3" LEAN CONCRETE
PLACED AHEAD OF WEATHER CONDITIONS FOR PROTECTION.
5. TO MINIMIZE WEATHERING, THE LAST 6 INCHES OF EXCAVATION FOR ALL FOOTINGS SHALL BE MADE
IMMEDIATELY PRIOR TO PLACEMENT OF FOOTINGS.
6. BEFORE PLACING CONCRETE FOOTINGS, VERIFY ELECTRICAL GROUNDING CONNECTIONS TO REBAR
ARE IN PLACE AND TESTED. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL REQUIREMENTS.
7. ALL SLABS ON GRADE SHALL BE PLACED OVER VAPOR RETARDER OVER 6" BASE OF WELL-COMPACTED
STONE. THE STONE SHALL BE PLACED ON ORIGINAL SOIL OR ON COMPACTED EARTH FILL AS
DESCRIBED ABOVE.
8. VAPOR RETARDER SHALL BE POLYETHYLENE SHEET IN ACCORDANCE WITH ASTM D4397, NOT LESS
THAN 15 MILS THICK.
9. PLACE CONCRETE FOR SLAB ON GRADE IN CONTINUOUS STRIPS AND PROVIDE CRACK CONTROL JOINTS AT LOCATIONS INDICATED ON PLAN OR A MAXIMUM SPACING OF 15 FEET ON CENTER, UNLESS
OTHERWISE NOTED.
CONCRETE:
1. CONCRETE MIXTURES SHALL COMPLY WITH ACI 301. PREPARE NORMAL-WEIGHT CONCRETE (145 PCF) DESIGN MIXES UNLESS OTHERWISE NOTED, PROPORTIONED ACCORDING TO ACI 301, AS FOLLOWS:
CLASS A: ACCESS CONTROL PEDESTAL, BARRIER ARM, AND BOLLARD FOOTINGS:
A. EXPOSURE CLASS: ACI 318 F1.
B. MINIMUM COMPRESSIVE STRENGTH: 3500 PSI AT 28 DAYS.
C. MAXIMUM WATER-CEMENTITIOUS MATERIALS RATIO: 0.55
D. SLUMP LIMIT: 4 INCHES +/- 1 INCH
E. AIR CONTENT: 4.5% (+/- 1.5%)
CLASS B: GUARD HOUSE SLAB AND CONCRETE ISLAND:
A. EXPOSURE CLASS: ACI 318 F3.
B. MINIMUM COMPRESSIVE STRENGTH: 5000 PSI AT 28 DAYS.
C. MAXIMUM WATER-CEMENTITIOUS MATERIALS RATIO: 0.40
D. SLUMP LIMIT: 3 INCHES +/- 1 INCH
E. AIR CONTENT: 6% (+/- 1.5%)
2. READY MIXED CONCRETE PRODUCER SHALL CONFORM TO QUALIFICATIONS BY ASTM C94.
3. MEASURE, BATCH, MIX, AND DELIVER CONCRETE ACCORDING TO ASTM C94 AND ASTM C1116. WHEN AIR TEMPERATURE IS ABOVE 90 DEG F, REDUCE MIXING AND DELIVERY TIME TO 60 MINUTES.
4. ALL DETAILING, FABRICATION AND PROCEDURES OF CONCRETE PLACEMENT SHALL CONFORM WITH THE LATEST EDITIONS OF ACI 301 - "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS", ACI 315 - "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT", AND ACI 318 - "BUILDING CODE
REQUIREMENTS FOR REINFORCED CONCRETE".
5. REINFORCING BARS SHALL BE ROLLED FROM NEW BILLET STEEL CONFORMING TO ASTM A615 AND BE
GRADE 60 DEFORMED, UNLESS OTHERWISE NOTED.
6. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 AND A82 HAVE END LAPS OF ONE FULL MESH
PLUS 2" BETWEEN CROSS WIRES AND EDGE LAPS OBTAINED BY OVERLAPPING LONGITUDINAL
SELVAGE WIRES 2" AND WIRING ALL LAPS SECURELY TOGETHER. WELDED WIRE FABRIC SHALL EXTEND INTO SUPPORT BEAMS AND WALLS FOR ANCHORAGE UNLESS AN EXPANSION JOINT IS INDICATED.
7. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR ALL REINFORCEMENT, UNLESS
OTHERWISE NOTED:
A. CONCRETE CAST AGAINST AND PERMANENTLY
EXPOSED TO EARTH 3"
B. CONCRETE EXPOSED TO EARTH OR WEATHER:
#6 THROUGH #18 BARS 2"
#5 BAR AND SMALLER 1 1/2"
C. CONCRETE NOT EXPOSED TO EARTH OR WEATHER:
SLABS, WALLS, AND JOISTS 3/4"
BEAMS AND COLUMNS 1 1/2"
8. ISOLATION JOINT MATERIAL SHALL BE 1/2" THICK ASPHALT-SATURATED CELLULOSIC FIBER IN
ACCORDANCE WITH ASTM D1751, UNLESS OTHERWISE NOTED.
9. LAP ALL REINFORCING SPLICES AT LEAST 48 BAR DIAMETERS UNLESS OTHERWISE NOTED. SPLICE
LOCATIONS SHALL BE STAGGERED FOR PARALLEL BARS.
10. ALL REINFORCING SHALL BE SECURELY WIRED TOGETHER IN FORMS AS CALLED FOR IN "PLACING
REINFORCING BARS" BY CRSI, LATEST EDITION.
11. NO TORCH CUTTING, HEAT BENDING, OR WELDING OF REINFORCING SHALL BE DONE, UNLESS
OTHERWISE NOTED.
12. CHAMFER EXPOSED EDGES OF CONCRETE 3/4" UNLESS OTHERWISE NOTED.
13. CEMENTITIOUS MATERIAL: USE CEMENTITIOUS MATERIALS, OF THE SAME TYPE, BRAND, AND SOURCE, THROUGHOUT PROJECT. PORTLAND CEMENT SHALL BE ASTM C150, TYPE 1/11, GRAY. SUPPLEMENT
WITH FLY ASH IN ACCORDANCE WITH ASTM C618, CLASS F AND GROUND GRANULATED
BLAST-FURNACE SLAG IN ACCORDANCE WITH ASTM C989, GRADE 100 OR 120. SILICA FUME SHALL BE
ASTM C1240, AMORPHOUS SILICA.
14. NORMAL-WEIGHT AGGREGATES: ASTM C33, CLASS 3S COARSE AGGREGATE OR BETTER, GRADED.
PROVIDE AGGREGATES FROM A SINGLE SOURCE WITH DOCUMENTED SERVICE RECORD DATA OF AT LEAST 10 YEARS' SATISFACTORY SERVICE IN SIMILAR APPLICATIONS AND SERVICE CONDITIONS USING SIMILAR AGGREGATES AND CEMENTITIOUS MATERIALS. MAXIMUM COARSE-AGGREGATE SIZE SHALL BE 1 INCH NOMINAL. FINE AGGREGATES SHALL BE FREE OF MATERIALS WITH DELETERIOUS REACTIVITY
TO ALKALI IN CEMENT.
15. WATER SHALL BE ASTM C94 AND POTABLE.
16. AIR-ENTRAINING ADMIXTURE SHALL CONFORM TO ASTM C260.
17. CHEMICAL ADMIXTURES SHALL CONFORM TO ASTM C494 AND BE WATER REDUCING. CONTRACTOR
SHALL NOT USE CALCIUM CHLORIDE OR ADMIXTURES CONTAINING CALCIUM CHLORIDE.
18. JOINT FILLER SHALL BE TWO COMPONENT, POLYUREA ELASTOMER, FLEXIBLE, 100 PERCENT SOLIDS FOR EXTERIOR APPLICATION. CONTRACTOR SHALL CONFIRM COMPATIBILITY OF JOINT FILLER/SEALANT
WITH FLOORING, SEALING, AND CURING MANUFACTURING.
19. COMPLY WITH THE LATEST EDITION OF CRSI'S “MANUAL OF STANDARD PRACTICE” FOR FABRICATING, PLACING, AND SUPPORTING REINFORCEMENT.
20. BEFORE PLACING CONCRETE, VERIFY THAT INSTALLATION OF FORMWORK, REINFORCEMENT, AND EMBEDDED ITEMS IS COMPLETE AND THAT ALL REQUIRED INSPECTIONS HAVE BEEN PERFORMED.
21. PLACE CONCRETE IN A CONTINUOUS OPERATION AND CONSOLIDATE USING MECHANICAL VIBRATING
EQUIPMENT.
22. PROTECT CONCRETE FROM PHYSICAL DAMAGE, PREMATURE DRYING, AND REDUCED STRENGTH DUE
TO HOT OR COLD WEATHER DURING MIXING, PLACING, AND CURING.
23. SLAB FINISHES SHALL COMPLY WITH ACI 302.1R RECOMMENDATIONS FOR SCREEDING,
RESTRAIGHTENING, AND FINISHING OPERATIONS FOR CONCRETE SURFACES. APPLY FINISHES TO
FLOORS AND SLABS NOTED BELOW:
A. BROOM FINISH SHALL BE APPLIED TO GUARD HOUSE SLAB, CONCRETE ISLAND, AND AS INDICATED.
IMMEDIATELY AFTER FLOAT FINISHING, SLIGHTLY ROUGHEN TRAFFICKED SURFACE BY BROOMING WITH FIBER-BRISTLE BROOM PERPENDICULAR TO MAIN TRAFFIC ROUTE. COORDINATE REQUIRED
FINAL FINISH WITH OWNER BEFORE APPLICATION.
24. SAW CUT CONTROL JOINTS (CJ) AS SHOWN ON PLAN AFTER INITIAL GEL AND WITHIN 24 HOURS OF
POUR. GEL MUST BE SUITABLE TO PREVENT SURFACE FRACTURING DURING SAW CUT.
25. BEGIN CURING CONCRETE SLABS AFTER FINISHING.
26. PROTECT CONCRETE FROM DAMAGE. REPAIR SURFACE DEFECTS IN FORMED CONCRETE AND SLABS.
27. DO NOT ADD WATER TO CONCRETE DURING DELIVERY, AT PROJECT SITE, OR DURING PLACEMENT UNLESS APPROVED BY STRUCTURAL ENGINEER OF RECORD. BEFORE TEST SAMPLING AND PLACING CONCRETE, WATER MAY BE ADDED AT PROJECT SITE, SUBJECT TO LIMITATIONS OF ACI 301 AND STRUCTURAL ENGINEER OF RECORD APPROVAL. DO NOT ADD WATER TO CONCRETE AFTER ADDING
HIGH-RANGE WATER-REDUCING ADMIXTURES TO MIXTURE.
28. DEPOSIT CONCRETE CONTINUOUSLY IN ONE LAYER OR IN HORIZONTAL LAYERS OF SUCH THICKNESS THAT NO NEW CONCRETE WILL BE PLACED ON CONCRETE THAT HAS HARDENED ENOUGH TO CAUSE
SEAMS OR PLANES OF WEAKNESS.
29. DEPOSIT AND CONSOLIDATE CONCRETE FOR SLABS IN A CONTINUOUS OPERATION. CONSOLIDATE
CONCRETE DURING PLACEMENT OPERATIONS SO CONCRETE IS THOROUGHLY WORKED AROUND
REINFORCEMENT AND OTHER EMBEDDED ITEMS AND INTO CORNERS. MAINTAIN REINFORCEMENT IN
POSITION ON CHAIRS DURING CONCRETE PLACEMENT. SCREED SLAB SURFACES WITH A
STRAIGHTEDGE AND STRIKE OFF TO CORRECT ELEVATIONS. SLOPE SURFACES UNIFORMLY TO DRAIN WHERE REQUIRED. BEGIN INITIAL FLOATING USING BULL FLOATS OR DARBIES TO FORM A UNIFORM
AND OPEN-TEXTURED SURFACE. DO NOT FURTHER DISTURB SLAB SURFACES BEFORE STARTING
FINISHING OPERATIONS.
30. COLD-WEATHER PLACEMENT: COMPLY WITH ACI 306.1 AND AS FOLLOWS. PROTECT CONCRETE WORK
FROM PHYSICAL DAMAGE OR REDUCED STRENGTH THAT COULD BE CAUSED BY FROST, FREEZING
ACTIONS, OR LOW TEMPERATURES. WHEN AVERAGE HIGH AND LOW TEMPERATURE IS EXPECTED TO FALL BELOW 40 DEG F FOR THREE SUCCESSIVE DAYS, MAINTAIN DELIVERED CONCRETE MIXTURE
TEMPERATURE WITHIN THE TEMPERATURE RANGE REQUIRED BY ACI 301. DO NOT USE FROZEN
MATERIALS OR MATERIALS CONTAINING ICE OR SNOW. DO NOT PLACE CONCRETE ON FROZEN
SUBGRADE OR ON SUBGRADE CONTAINING FROZEN MATERIALS. DO NOT USE CALCIUM CHLORIDE, SALT, OR OTHER MATERIALS CONTAINING ANTIFREEZE AGENTS OR CHEMICAL ACCELERATORS
UNLESS OTHERWISE SPECIFIED AND APPROVED IN MIXTURE DESIGNS.
31. HOT WEATHER PLACEMENT SHALL COMPLY WITH ACI 301. MAINTAIN CONCRETE TEMPERATURE BELOW 90 DEG F AT TIME OF PLACEMENT. CHILLED MIXING WATER OR CHOPPED ICE MAY BE USED TO CONTROL TEMPERATURE, PROVIDED WATER EQUIVALENT OF ICE IS CALCULATED TO TOTAL AMOUNT
OF MIXING WATER. USING LIQUID NITROGEN TO COOL CONCRETE IS CONTRACTOR'S OPTION.
FOG-SPRAY FORMS, STEEL REINFORCEMENT, AND SUBGRADE JUST BEFORE PLACING CONCRETE.
KEEP SUBGRADE UNIFORMLY MOIST WITHOUT STANDING WATER, SOFT SPOTS, OR DRY AREAS.
32. CURE CONCRETE ACCORDING TO ACI 308.1 MOISTURE CURING: KEEP SURFACES CONTINUOUSLY MOIST FOR NOT LESS THAN SEVEN DAYS WITH WATER, CONTINUOUS WATER-FOG SPRAY, ABSORPTIVE
COVER, WATER SATURATED, AND KEPT CONTINUOUSLY WET. COVER CONCRETE SURFACES AND
EDGES WITH 12 INCH LAP OVER ADJACENT ABSORPTIVE COVERS.
33. OWNER SHALL ENGAGE A TESTING AND INSPECTION FIRM TO PERFORM FIELD TESTS ON CONCRETE
AND REBAR AND TO SUBMIT TEST REPORTS FOR VALIDATION WITH DESIGN PARAMETERS NOTED
ABOVE.
34. INSPECTIONS SHALL INCLUDE STEEL REINFORCEMENT PLACEMENT, VERIFICATION OF USE OF REQUIRED DESIGN MIXTURE, CONCRETE PLACEMENT, INCLUDING CONVEYING AND DEPOSITING, AND
CURING PROCEDURES AND MAINTENANCE OF CURING TEMPERATURE.
35. CONCRETE TESTS: TESTING OF COMPOSITE SAMPLES OF FRESH CONCRETE OBTAINED ACCORDING TO ASTM C172. TESTING FREQUENCY: OBTAIN ONE COMPOSITE SAMPLE FOR EACH DAY'S POUR OF EACH CONCRETE MIXTURE EXCEEDING 5 CUBIC YARDS, BUT LESS THAN 25 CUBIC YARDS, PLUS ONE
SET FOR EACH ADDITIONAL 50 CUBIC YARDS OR FRACTION THEREOF.
36. SLUMP: ASTM C143; ONE TEST AT POINT OF PLACEMENT FOR EACH COMPOSITE SAMPLE, BUT NOT LESS THAN ONE TEST FOR EACH DAY'S POUR OF EACH CONCRETE MIXTURE. PERFORM ADDITIONAL
TESTS WHEN CONCRETE CONSISTENCY APPEARS TO CHANGE.
37. AIR CONTENT: ASTM C231, PRESSURE METHOD, FOR NORMAL-WEIGHT CONCRETE; ONE TEST FOR
EACH COMPOSITE SAMPLE, BUT NOT LESS THAN ONE TEST FOR EACH DAY'S POUR OF EACH
CONCRETE MIXTURE.
38. COMPRESSION TEST CYLINDERS: ACI 318; CAST AND LABORATORY CURE THREE SETS OF TWO 6 x 12 INCH CYLINDERS OR THREE SETS OF THREE 4 x 8 INCH CYLINDERS FOR EACH COMPOSITE SAMPLE.
TEST ONE SET OF LABORATORY CURED CYLINDERS AT 7 DAYS AND ONE SET AT 28 DAYS. HOLD ONE SET OF LABORATORY CURED CYLINDERS IN RESERVE. ALSO, CAST AND FIELD CURE ONE SET OF TWO 6 x 12 INCH CYLINDERS OR ONE SET OF THREE 4 x 8 INCH CYLINDERS. THE FIELD CURE CYLINDERS ARE
TO BE HELD IN RESERVE AND ONLY BROKEN IF THE LABORATORY CURED CYLINDERS FAIL. A
COMPRESSIVE STRENGTH TEST SHALL BE THE AVERAGE OF THE STRENGTHS OF ONE SET OF TWO 6 x 12 INCH CYLINDERS OR ONE SET OF THREE 4 x 8 INCH CYLINDERS MADE FROM THE SAME COMPOSITE SAMPLE. CONTRACTOR SHALL EVALUATE OPERATIONS AND PROVIDE CORRECTIVE PROCEDURES FOR
PROTECTING AND CURING IN-PLACE CONCRETE.
39. STRENGTH OF EACH CONCRETE MIXTURE WILL BE SATISFACTORY IF EVERY AVERAGE OF ANY THREE
CONSECUTIVE COMPRESSIVE-STRENGTH TESTS EQUALS OR EXCEED SPECIFIED COMPRESSIVE
STRENGTH AND NO COMPRESSIVE STRENGTH TEST VALUE FALLS BELOW SPECIFIED COMPRESSIVE
STRENGTH BY MORE THAN 500 PSI.
40. TEST RESULTS SHALL BE REPORTED IN WRITING TO OWNER, A/E, AND CONTRACTOR WITHIN 48 HOURS OF TESTING. REPORTS OF COMPRESSIVE-STRENGTH TESTS SHALL CONTAIN PROJECT IDENTIFICATION NAME AND NUMBER, DATE OF CONCRETE PLACEMENT, NAME OF CONCRETE TESTING AND INSPECTION FIRM, LOCATION OF CONCRETE BATCH IN WORK, DESIGN COMPRESSIVE STRENGTH AT 28 DAYS, CONCRETE MIXTURE PROPORTIONS AND MATERIALS, COMPRESSIVE BREAKING STRENGTH, AND TYPE
OF BREAK FOR BOTH 7- AND 28-DAY TESTS.
41. ADDITIONAL TESTS: TESTING AND INSPECTION FIRM SHALL MAKE ADDITIONAL TESTS OF CONCRETE WHEN TEST RESULTS INDICATE THAT SLUMP, AIR ENTRAINMENT, COMPRESSIVE STRENGTHS, OR OTHER REQUIREMENTS HAVE NOT BEEN MET. TESTING AND INSPECTION FIRM MAY CONDUCT TESTS TO DETERMINE ADEQUACY OF CONCRETE BY CORED CYLINDERS COMPLYING WITH ASTM C42 OR BY
OTHER METHODS.
42. ADDITIONAL TESTING AND INSPECTING, AT CONTRACTOR'S EXPENSE, WILL BE PERFORMED TO DETERMINE COMPLIANCE OF REPLACEMENT OR ADDITIONAL WORK WITH SPECIFIED REQUIREMENTS.
43. CORRECT DEFICIENCIES IN THE WORK THAT TEST REPORTS AND INSPECTIONS INDICATE DO NOT
COMPLY WITH THE CONTRACT DOCUMENTS.
GENERAL NOTES
AS3
WILLIAM L. ALLEN
Lic. No. 034677
03/13/2026
IFB # 160775
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text F
AutoCAD SHX Text V
AutoCAD SHX Text A
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text T
CONSTRUCTION NOTE
DEMOLITION NOTE
SYMBOLS ABBREVIATIONS
MDP-1
MDP-1
INDICATES MULTIPLE HOMERUN CIRCUITS FROM SINGLE
PANEL/CIRCUIT.
HOMERUN TO PANEL AND CIRCUIT NUMBER AS…
This is the start of the file's text. The full file is on GovTribe.