(ELECTRICAL)
POWER AND CONTROL
CONDUITS (SEE
4" SAN
TOP ELEV 3463.50
2" D
IP
FIN GR
INV 3460.00
BOT EL. 3452.25
HLA EL. 3458.50
PUMP #1
START EL. 3456.00
STOP PUMPS
EL. 3453.75
2" FM
CL EL. 3459.00
FIBERGLASS
PUMP STATION
4"
GOOSE NECK VENT
W/ SST INSECT SCREEN
PUMP #2
START EL. 3457.00
GRINDER
PUMP (2)
4" GRANULAR FILL
2" GATE VALVE
2" HDPE W/ 2"
GATE VALVE
SANITARY SEWER LIFT STATION
W/2 GRINDER PUMPS
(LOCAL PANEL LOCATED IN GARAGE)
#4 BAR (TYP)
VARIES
COVER
MAX
2'-0"
18" SQUARE X 6"
THICK CONCRETE
COLLAR WHEN NOT IN
PAVEMENT, SEE
DETAIL THIS SHEET
PROVIDE VALVE STEM
EXTENSION AND STEM
CENTERING PLATE
WITHIN 18" OF SURFACE
MAIN LINE VALVES TO HAVE
JOINTS SAME AS MAIN OR AS
SPECIFIED FOR MAIN LINE
FITTINGS
NOTE:
1. RESTRAIN VALVE AND
NEARBY JOINTS PER
REQUIREMENTS OF
RESTRAINED PIPE
CONCRETE COLLAR WORD "WATER" ON COVER OF PW AND
NPW. ALL OTHER SERVICES LETTERED
"SEWER"
ADJUSTABLE C.I. VALVE
BOX 5" BARREL
VALVE BOX SHALL NOT
BEAR DIRECTLY ON
BODY OF VALVE
3" MIN
(TYP)
(TYP)
1" MIN
#4 BAR (TYP)
WATER
18"
CONCRETE COLLAR
EX AERATION BASIN
TOP OF CONCRETE
3467.67±
W.S.ELEV
3465.67±
3445.5 ±
8"
3' MIN
NEW 2" HDPE
SEWER FORCE MAIN
EX GRADE
3463.5±
12"±
UNISTRUT PIPE
SUPPORT
SEE DETAIL
MOUNT UNISTRUT TO
SUPPORT PER MFG
INSTRUCTIONS
UNISTRUT
SEE NOTE 1
NOTES:
UNISTRUT PIPE SUPPORT DETAIL
PIPE CLAMP (TYP)
CL EL 3459.00
1" PLUG VALVE
FOR AIR RELEASE
NEW BASE COURSE
UTILITY
NEW PAVEMENT SURFACE OR EXISTING ROADWAY
8" LIFTS MAX
MARKER TAPE
1' -6
WIDTH
SEE TABLE
12"
DENSITY SEE NOTE 2
3' -0
" M
IN
C O
V
ER
IN OPEN FIELD IN STREET OR ROADWAY
FINAL GRADE
LI
M
IT
S
O F
B
ED
D
IN
G
6"
NOTES:
1. IF UNSTABLE MATERIALS ARE FOUND IN TRENCH
BOTTOM, OVER EXCAVATE AND PLACE 1 1/2"
STABILIZATION ROCK TO REQUIRED DEPTH FOR
STABLE TRENCH BOTTOM. PLACE 12 MIL
POLYETHYLENE BETWEEN ROCK AND SQUEEGEE
BEDDING
2. BACKFILL WITH ENGINEERING FILL UNDER
ROADWAYS COMPACT TO 90% STD PROCTOR
DENSITY IN NON-DRIVING SURFACES
3. SHOULD THE TRENCH BE EXCAVATED WIDER
THAN ALLOWED, A CONCRETE CRADLE SHALL BE
PLACED WITH 2500 PSI CONCRETE FROM
TRENCH BOTTOM TO PIPE SPRINGLINE
4. TRENCH TO BE BRACED OR SHEETED AS
NECESSARY FOR THE SAFETY OF THE WORKMEN
AND THE PROTECTION OF OTHER UTILITIES IN
ACCORDANCE WITH LOCAL, STATE AND FEDERAL
SAFETY REGULATIONS
5. MINIMUM COVER TO BE 3'-0" BELOW FINAL
GRADE, UNLESS SHOWN OTHERWISE
6. EARTHMOVING PER SPEC SECTION
7. ASPHALT PAVING PER SPEC SECTION
SEE NOTES 1,2 & 3
3'-2"
3'-6"
3'-0"
MAXIMUM
WIDTH
2'-4"
2'-8"
2'-6"
3'-0"10"
14"
18"
12"
6"
8"
3",4"
2'-0"
2'-2"
2'-6"
2'-0"
1'-4"
1'-8"
1'-6"
PIPE
DIAMETER
MINIMUM
WIDTH
3'-6"16" 2'-6"
Copyright: Tetra Tech w w w .te tra te ch .c om
M
AR
K D
A
TE
D
ES
C R
IP
TI
O N
BY
7/
/2
:3 3:
A
M
P :\0
\1
-0
-1
\C A
D \S
H E
E
TF
IL
E
S \C
-5
-D E
TA
IL
S -P
AV
IN
G
P
IP
IN
G
D W
G .D
W G
- S
TO
R
E Y
, M
IC
H A
EL
A
B
C
D
E
F
2 3 4 5 6 7
N og al es
In te rn at io na l W as te w at er
T re at m en t P la nt
A dm in is tra tio n/ O
M
B ui ld in g
E . W as hi ng to n S tre et
, S ui te
P ho en ix , A
Z
P H
O N
E
2)
-3
F
A X
2)
-3
PA
V
IN
G
P
IP
IN
G D
E
TA
IL
S
C-501
2" FORCE MAIN DISCHARGE TO EX AERATION BASIN DETAIL2
- NTS
TYPICAL TRENCH DETAIL6
- NTS
NOT USED7
- NTS
NOT USED5
- NTS
GATE VALVE DETAIL3
- NTS
SANITARY SEWER LIFT STATION DETAIL1
- NTS
NOT USED4
- NTS
PLAN
NTS
http://www.tetratech.com/
6" MINIMUM
1-1/2" - 3" ROCK
1/2" - 3/4" FILTER LAYER
1. SET POSTS.
4. FINISHED SECTION
4"
RUNOFF
M
IN
2. EXCAVATE A 4"x4" TRENCH ON
THE UPSLOPE SIDE ALONG THE
LINE OF UPRIGHTS.
3. ATTACH FILTER MATERIAL TO POSTS OR INSERT
SEWN POCKETS OVER POSTS AND EXTEND IT INTO
THE TRENCH.
WOODEN OR STEEL
FENCE POSTS
FILTER FABRIC,
ATTACH
APPROX. 4"x4"
TRENCH. BACKFILL
AFTER INSTALLING
FABRIC
TOE OF FILL
EROSION
A
BALES
2:1
9 FT MIN.
EXCAVATED
AREA
15 FT MIN.
AREA
CONTAINMENT
3:1
CONCRETE WASHOUT
PLAN VIEW
AEXCAVATED AREA
EXISTING GROUND
2 FT MIN.
4 IN.
NOTES:
CROSS-SECTION A-A
1. CONCRETE WASTE SHALL BE PLACED IN A TEMPORARY CONCRETE WASHOUT
FACILITY LOCATED A MINIMUM OF 50 FEET FROM DRAINAGE WAYS AND INLETS.
2. CONCRETE WASHOUT FACILITIES WILL COMPRISE OF AN EXCAVATION WITH
EROSION BALES AND CONSTRUCTION FENCES.
3. PROPER SIGNAGE SUCH AS "CONCRETE WASHOUT" OR "CONCRETE SAW
WATER DISPOSAL" SHALL BE PLACED NEAR CONCRETE WASHOUT FACILITIES.
4. ADDING SOLVENTS, FLOCCULENTS, OR ACID TO WASHWATER IS PROHIBITED.
EROSION BALE
1' -0
1% MIN
PROVIDE:
1. CONTROL JOINT 5'-0" O.C.
2. EXPANSION JOINTS EVERY 3RD JOINT:
JOINT FILLER 1/2" BITUMINOUS TYPE
PREFORMED EXPANSION JOINT FILLER
A.S.T.M. D-1751
Copyright: Tetra Tech w w w .te tra te ch .c om
M
AR
K D
A
TE
D
ES
C R
IP
TI
O N
BY
7/
/2
:1 3:
P
M
P :\0
\1
-0
-1
\C A
D \S
H E
E
TF
IL
E
S \C
-5
-D E
TA
IL
S -E
R O
S
IO
N C
O N
TR
O
L
P
AV
IN
G
.D
R E
Y , M
IC
H
A
EL
A
B
C
D
E
F
2 3 4 5 6 7
N og al es
In te rn at io na l W as te w at er
T re at m en t P la nt
A dm in is tra tio n/ O
M
B ui ld in g
E . W as hi ng to n S tre et
, S ui te
P ho en ix , A
Z
P H
O N
E
2)
-3
F
A X
2)
-3
E R
O S
IO
N
C O
N
TR
O L
- P A
V
IN
G D
E
TA
IL
S
C-502
VEHICLE TRACKING CONTROL1
C-100 NTS
SILT FENCE2
- NTS
CONCRETE WASHOUT3
- NTS
TYPICAL PAVEMENT SECTION4
- NTS
TYPICAL CURB SECTION5
- NTS
5' SIDEWALK SECTION6
- NTSA
WHEEL
STOP
HANDICAP PARKING DETAIL7
- NTS
STRIPPING DETAIL8
- NTS
WHEEL STOP DETAILA
- NTS
A
WHEEL
STOP
A
B B
R E
V
IA
TI
O
N S
E
LE
C
TR
IC
A
L
LE
G E
N D
E-001
X CCT a
FV FLOW VALVE
RUNNING TIME METER
LINEAR FEET
LEVEL CONTROL VALVE
LEVEL ELEMENT TRANSMITTER
LEVEL INDICATING CONTROLLER
LEVEL INDICATOR
LEVEL INDICATING RECORDER
HIGH/LOW LEVEL SWITCH
LOW LEVEL SWITCH
LOUVER MOTOR
LOCK-OUT STOP
HIGH LEVEL SWITCH
LATCHING RELAY
LOCAL-OFF-REMOTE
HIGH LEVEL LAMP
LOW LEVEL ALARM
LLH
LR & L
LSL
LSHL
LSH
LOR
LOS
LM
LF
LIC
LIR
LI
LCV
LET
LAL
HEATERHTR
INTERLOCK
KILOWATT
TIME RELAY
HIGH LEVEL ALARM
LIGHTING PANEL 6
HIGH/LOW CURRENT SWITCH
REACTIVE KILOVOLT AMPERES
KILO VOLT-AMPERES
TIME CONTROL
JUNCTION BOX
INTERVAL TIMER
ISOLATED GROUND
K
KW
KY
L6
LAH
KVA
KC
KVAR
KEY
ISHL
J OR JB
INT
HZ
I
IG
HERTZ
GROUND
HAND-OFF-AUTO
HAND SWITCH
HAND RESET OR HOUR
HIGH PRESSURE SODIUM
GROUND BUS
HANDLE CLIP OR HORN
FLOW RELAY
HAND CONTROL
GRINDER PUMP
FULL VOLTAGE REVERSING
GAS, GROUND, GREEN
GROUND FAULT CURRENT INTERRUPTER
GROUPGRP
HOA
HR
HPS
HS
H
HI
HC
HIGH
GB
GP
GND
GFCI
FY
G
FVR
Y WYE CONTACTOR OR AUXILIARY RELAY
PERCENTAGE
POSITION SWITCH CLOSED
POSITION SWITCH OPEN
BACKWASH COUNTER
LOW MOISTURE SWITCH
STATUS CONTROL
STATUS INDICATION
MOISTURE ALARM LOW
ZSC
YQI
YSL
ZSO
YC
YL
YAL
TDE TIME DELAY ON ENERGIZATION
VOLT SWITCH
VOLTMETER
UNDERGROUND
VOLTS
TRANSFORMER
WASTE SLUDGE PUMP
AUXILIARY RELAY
WEIGHT INDICATION
WIRE, WATTS OR WEATHERPROOF
WEATHERPROOF
UNINTERUPTIBLE POWER SYSTEM
COMMON ALARM
TIME DELAY OPENING CONTACT
TEMPERATURE INDICATION
VM
WSP
XFMR
WP
X
WWI
VS
UA
UPS
V
UG
TO
TI
OR THERMAL OVERLOAD
THERMOSTAT OR TELEPHONE
SOLENOID VALVE
TIME DELAY ON DE-ENERGIZATION
TIME DELAY RELAY
TIME CLOSING CONTACT
SLUDGE PUMP OR SUMP PUMP
SELECTOR SWITCH
START CONTACTOR OR VALVE
NEMA SIZE 2 STARTER
SULFUR DIOXIDE
SHEET OR SPACE HEATER
SECONDARY OR SECONDS
SPEED CONTROL
SODA ASH PUMP
REDUCED VOLTAGE, NON REVERSING
T
TD
TC
TDD
SP
SV
SS
RVNR
SH
SO
SEC
SC
SAP
S2 S
ELECTRICAL ABBREVIATIONS
B BLOWER OR PANEL B OR BELL
ENCL ENCLOSURE
FLOW INDICATOR
FLOW INDICATING TRANSMITTER
FLOW INDICATOR RECORDER
FLOW INDICATOR CONTROLLER
FLOW TOTALIZING INDICATOR
FLOW TRANSMITTER
FIRE ALARM
FLOW ALARM HIGH
VOLTAGE SWITCH LOW
FLOW CONTROL
FLOW ELEMENT
FLOW CONTROL VALVE
EXPLOSION PROOF
EXTENSION
FIR
FQI
FT
FIT
FI
FE
FIC
EP OR E
FA
FCV
FC
FAH
ESL
EXTN
COPPER
DISCONNECT SWITCH
DAMPER MOTOR
DURATION TIMER
CORROSION RESISTANT
BARE COPPER
DECANT PUMP
BACKWASH PUMP
CIRCUIT BREAKER
ELEVATION
ELECTRIC HEATER
ELECTRICAL HANDHOLE
VOLTAGE ALARM LOW (PHASE LOSS)EAL
EL
EH
EHH
DS
DM
DUR
C
CR
CT
CU
DP
BC
BWP
BKR
ANALYSIS INDICATOR
ABOVE FINISHED FLOOR
ABOVE COUNTER
HIGH ANALYSIS ALARM
AMPERES OR AMBER OR AERATOR
AMPS INTERRUPTING CURRENT
AMMETER SWITCH
ALUM PUMP
ALTERNATOR
ANALYSIS INDICATING RECORDER
AMMETER
ADVANCED WASTEWATER TREATMENT
ANALYSIS INDICTING TRANSMITTER
AM
AP
AS
AWT
ALT
AIR
AIT
AAH
AI
AC
AFF
AIC
A
NAH HIGH TORQUE ALARM
PRESSURE DIFFERENTIAL ALARM HIGH
PROCESS & INSTRUMENTATION DIAGRAM
DIFFERENTIAL PRESSURE TRANSMITTER
HIGH DIFFERENTIAL PRESSURE SWITCH
RECEPTACLES
DAMPER
PRIMARY
PANEL
RED, RELAY, OR RUN
LOW PRESSURE SWITCH
HIGH PRESSURE SWITCH
PROGRAMMABLE LOGIC CONTROLLER
POLYMER PUMP
PRESSURE INDICATOR
DIFFERENTIAL PRESSURE INDICATOR
PRESSURE CONTROL VALVE
RECEPS
PSL
RG
R
RTM
PRI
PP
PSH
PDSH
PDAH
PDT
PNL
PLC
PI
PCV
PDI
ON-OFF
NEUTRAL BUS
OPEN/CLOSE
NEUTRAL
TWO POLE
OUTPUT
OPEN/CLOSE-AUTO
POWER PANEL 1
PHOTOELECTRIC CELL
ON-OFF-RESET
OVERLOAD RELAY
HIGH TORQUE SWITCH
HIGH TORQUE SWITCH
NATIONAL ELECTRIC CODE
OCA
P&ID
2P
PE
P1
OOR
OO
OL
OUT
NSHH
NEUT
NEMA
NP
NSH
OC
NEC
LEVEL RELAY
MAXIMUM
MOTOR
DIRECT CURRENT MILLIAMPERES
MAIN CONTROL PANEL
MOUNTING HEIGHT
MANUAL MOTOR STARTER
MINUTES OR MINIMUM
THOUSAND CIRCULAR MILLS
MOTOR CONTROL CENTER
LEVEL TRANSMITTER OR LIGHT
LIGHTING AND LIGHTS
MAX
MCC
MCM
MIN
MS
MTR
MTH
MCP
MADC
LTG & LTS
LY
M
LT
EF EXHAUST FAN
T
FACP
MS
HD
I
THERMOSTAT
FIRE SYSTEM MANUAL PULL STATION
FIRE SYSTEM THERMAL DETECTOR
FIRE SYSTEM IONIZATION DETECTOR
FIRE ALARM CONTROL PANEL
WELDING RECEPTACLES
UTILITY OWNED TELEPHONE LINE
UTILITY OWNED OVERHEAD POWER LINE
T
P
PLAN LEGEND
COMBINATION MOTOR STARTER
ENCASED UNDERGROUND DUCT BANK
OL
P10
TO
WP
K
M
MOTOR SWITCH WITH THERMAL OVERLOAD DEVICES
WEATHERPROOF RECEPTACLE
MOMENTARY SWITCH
KEY SWITCH
WIRING DEVICES
E
W
EXPLOSION-PROOF SWITCH
WEATHERPROOF SWITCH
3-WAY SWITCH
2 POLE SWITCH
3 POLE 20 AMP CIRCUIT BREAKER
SOLID STATE REDUCED VOLTAGE MOTOR STARTER
GROUND CONNECTION
CAPACITOR
MANUAL MOTOR STARTER
CURRENT TRANSFORMER
ONE LINE LEGEND
LIGHTNING AND SURGE ARRESTOR
FLUORESCENT FIXTURE
"X" DESIGNATES TYPE FIXTURE PER SCHEDULE
"CCT" DESIGNATES LIGHTING PANEL AND CIRCUIT
LETTER "a" DESIGNATES SWITCH
MANUAL MOTOR STARTERMS
CCT
A
WALL MOUNTED FIXTUREX
V EMERGENCY "FROG-EYE" FIXTURE
WATER HEATERWH
N NETWORK
CYCLE TIMER CLUTCH OR
CONTACT OR CONDUIT
CYCLE TIMER OR
CURRENT TRANSFORMER
MOTOR STARTER COIL OR CYCLE TIMER
MOTOR OR MOTOR
NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
WI
UNDERGROUND GROUND CIRCUIT
W/ GROUNDING ROD
DISCONNECT SWITCH (NON-FUSED
UNLESS OTHERWISE STATED)
TRANSIENT VOLTAGE SURGE SUPPRESSORTVSS
CIRCUIT HOME RUN WITH CIRCUIT DESIGNATION
SSRV
3P-20A
S2
X
T
LP-2
END OF LINE RESISTORELR
a
LIGHT SWITCH - LOWER CASE LETTER REFERS TO ITS
RESPECTIVE CONTROLLED LIGHTING FIXTURE
THE NUMBERS ADJACENT TO THE RECEPTACLE
INDICATE THE CIRCUIT NUMBER THAT THE
DEVICE IS CONNECTED TO
4 4-WAY SWITCH
3P 3 POLE, 600V RECEPTACLE
TELEPHONE OUTLET - 4" SQ X 2-1/2" D JUNCTION BOX
WITH A SINGLE GANG RING AND
BLANK COVER WITH 3/4" CONDUIT ROUTED TO
TELEPHONE TERMINAL BOARD OR JUNCTION BOX
WIRE. MOUNTING HEIGHT 18" AFF AS INDICATED. ALL
RACEWAYS TO CONTAIN PULL
N
NETWORK OUTLET
SL FIRE SYSTEM STROBE LIGHT
H FIRE SYSTEM HORN / STROBE LIGHT
SEE LIGHTING FIXTURE
SCHEDULE ON SHEET E-501
MOTOR WITH ASSUMED HORSEPOWER. ACTUAL HORSEPOWER
MAY DIFFER - INCREASE CIRCUIT SIZE AS REQUIRED
TRANSFORMER WITH PRIMARY VOLTAGE, SECONDARY VOLTAGE
AND KVA RATING SHOWN
SIZE 2 CIRCUIT BREAKER, COMBINATION FULL VOLTAGE
NON REVERSING STARTER. RVNR = REDUCED VOLTAGE
NON REVERSING STARTER
J JUNCTION BOX
Copyright: Tetra Tech w w w .te tra te ch .c om
M
AR
K D
A
TE
D
ES
C R
IP
TI
O N
BY
7/
/2
2:
:5
P
M
P :\0
\1
-0
-1
\C A
D \S
H E
E
TF
IL
E
S \E
-0
E
LE
C
TR
IC
A
L
LE
G E
N D
A
BB
R
E
VI
AT
IO
N S
.D
R E
Y , M
IC
H
A
EL
A
B
C
D
E
F
2 3 4 5 6 7
N og al es
In te rn at io na l W as te w at er
T re at m en t P la nt
A dm in is tra tio n/ O
M
B ui ld in g
E . W as hi ng to n S tre et
, S ui te
P ho en ix , A
Z
P H
O N
E
2)
-3
F
A X
2)
-3
P
GROUND ROD
(TYP)
R
#4/0 BARE CU
GROUND MAT
(TYP)
R
LI
G
H
TI
N G
P
O W
E R
P
LA
N E
LE
C
TR
IC
A L
SI
TE
E-101
0 5 10 20
N
GENERAL NOTES:
1. FIXTURES TYPE "H","K","L","M", THIS SHEET SWITCHED
BY ASTRONOMIC DIAL TIME CLOCK
2. CONTRACTOR SHALL PROVIDE A COMPLETE CODE
COMPLIANT GROUNDING & LIGHTNING PROTECTION
SYSTEM FOR THE ADMINISTRATION BLDG,
GENERATOR, ELECTRIC CLOSET COMPUTER
EQUIPMENT, ELECTRIC SERVICE FOR PARKING
SPACES, WITH DESIGN DRAWINGS SHOWING
QUANTITIES OF EACH DEVICE & DIMENSIONS. THESE
DRAWINGS SHALL BE ELABORATED BY A
SPECIALIZED ENGINEER
Copyright: Tetra Tech w w w .te tra te ch .c om
M
AR
K D
A
TE
D
ES
C R
IP
TI
O N
BY
7/
/2
2:
:4
P
M
P :\0
\1
-0
-1
\C A
D \S
H E
E
TF
IL
E
S \E
-1
-E
LE
C
TR
IC
A
L S
IT
E
L
IG
H
TI
N G
P
O W
E R
P
LA
N .D
R
E Y
, M
IC
H A
EL
A
B
C
D
E
F
2 3 4 5 6 7
N og al es
In te rn at io na l W as te w at er
T re at m en t P la nt
A dm in is tra tio n/ O
M
B ui ld in g
E . W as hi ng to n S tre et
, S ui te
P ho en ix , A
Z
P H
O N
E
2)
-3
F
A X
2)
-3
SUPERINTENDENT
LEAD OPERATOR OFFICE 2
LAUNDRY
WORK BAY
CONFERENCE
ENTRY
TOILET
CORRIDOR 1
WOMENS
MENS
CORRIDOR 2
ab a b a b a a a ba b a a b
OFFICE 1
ba b a a b
OFFICE PLOTTER
A b
A a b a a b d d d d d d d
D
A
A A
A A
A A
A A
A A
A
A
A
A
A
AA
A
AAAAAA
D
DD
d
A
A
A
A b
A b
A b a b cE c
E c
E c
E c
B
B
B
B
D b
D b
D b
D d D d F d b a
DIMMER
b b b a b
A
A
A
D c
D c
D c D c a a b c
3 3
D b D b
D b
D a D a
D a D a
D a a b
G a G b G a a b a 3 b 3 a 3 b 33 a
G a G b G a
G a G b G a
LP-13 LP-13 LP-13
LP-13LP-13LP-13
LP-13 LP-13 LP-13
LP-11
LP-11
LP-11
LP-11
LP-11
LP-11 LP-11
LP-3 LP-3
LP-3LP-3
LP-1 LP-1
LP-1
LP-1
LP-1
LP-1 LP-1
d
LP-1 LP-1 LP-1 LP-1 LP-1LP-1
LP-5 LP-5
LP-5LP-5
LP-5 LP-5
LP-9 LP-9 LP-9 LP-9
LP-9 LP-9
LP-9 LP-9
LP-9 LP-9
LP-9 LP-9
LP-9 LP-9
LP-5 LP-5
LP-5 LP-5
LP-7 LP-7LP-7
LP-7
LP-7LP-7 LP-7
LP-11 LP-11
LP-7
d
"G" FIXTURES TO BE SURFACE MOUNTED
TO UNDERSIDE OF ROOF DECK
c
N
LP-21
N
LP-21
N
LP-21
N
LP-21
N
LP-21
N
LP-21
F b
N
LP-4
N
LP-21
EL
E
C
TR
IC
AL
L
IG
H
TI
N G
P
LA
N
E-102
N
LIGHTING PLAN
SCALE: 1/4"=1'-0"
Copyright: Tetra Tech w w w .te tra te ch .c om
M
AR
K D
A
TE
D
ES
C R
IP
TI
O N
BY
7/
/2
2:
:1
P
M
P :\0
\1
-0
-1
\C A
D \S
H E
E
TF
IL
E
S \E
LE
C
TR
IC
A L
LI
G
H
TI
N G
P
LA
N .D
R
E Y
, M
IC
H A
EL
A
B
C
D
E
F
2 3 4 5 6 7
N og al es
In te rn at io na l W as te w at er
T re at m en t P la nt
A dm in is tra tio n/ O
M
B ui ld in g
E . W as hi ng to n S tre et
, S ui te
P ho en ix , A
Z
P H
O N
E
2)
-3
F
A X
2)
-3
OFFICE PLOTTER LEAD OPERATOR
OFFICE 1 OFFICE 2
LAUNDRY
WORK BAY
CONFERENCE
ENTRY
TOILET
CORRIDOR 1
WOMENS
MENS
ELECTRICAL
CLOSET
CORRIDOR 2
T
N
SD
LP-24
TELE
NETWORK
SEE NOTE 1
SD
J
SEE NOTE 2
SEE NOTE 3
LP-24LP-24
TELE
NETWORK
SEE NOTE 1
3"C
EL DS PS
CR
C
N
N T
SD DDSD
NT
N T
SD SD
N T
SD
S
DS PS
HD
SD
SD
H
S S
SD
DS
PS
T
H
H
M
EL
CR
PS
C
SD
SD
H
C
DS
EL
CR
PS
DS
H
S
FACP
LP-26
T
N
M
TELEPHONE OUTLET
NETWORK OUTLET
MOTION SENSOR
DS DOOR SWITCH
PAGING SPEAKERS
CAMERAC
CR CARD READER
SYMBOLS:
EL ELECTRIC LOCK
H FIRE HORN/STROBE
PS FIRE PULL STATION
HD HEAT DETECTOR
DD DUCT DETECTOR
SD INTRUSION DETECTION
PUSHBUTTON STATION
S
SD
GB GLASS BREAK DETECTOR
GB
GB
GB
GB
GB GB GB
SD PHOTOELECTRIC
SMOKE DETECTOR
F
S
TAMPER
SWITCH
SPRINKLER
FLOW SWITCH
SD
H
SD
SDSD
SD
CR C
EL
SL FIRE STROBE LIGHT
SLSL
SD
SL
SL
SL
SE
C
U R
IT
Y
PL
AN
C O
M M
U N
IC
A
TI
O
N
E-104
N
PLAN
SCALE: 1/4"=1'-0"
NOTES:
1. PROVIDE FLUSH MOUNTED FLOOR BOXES WITH DUPLEX
RECEPTACLE, TELEPHONE OUTLET, & NETWORK OUTLET
2. PROJECTOR VIDEO OUTLET
3. JUNCTION BOX ABOVE CEILING FOR PROJECTOR
4. WHERE MULTIPLE OUTLETS ARE SHOWN ADJACENT TO EACH
OTHER, OUTLETS MAT BE COMBINED IN SINGLE FACEPLATE ON
SINGLE GANG BOX
5. ELECTRICAL CLOSET TO CONTAIN EQUIPMENT FOR SECURITY
SYSTEM, CCTV, TELEPHONE, INTRUSION SYSTEM, NETWORK &
ACCESS SYSTEM
Copyright: Tetra Tech w w w .te tra te ch .c om
M
AR
K D
A
TE
D
ES
C R
IP
TI
O N
BY
7/
/2
2:
:2
P
M
P :\0
\1
-0
-1
\C A
D \S
H E
E
TF
IL
E
S \E
-1
C O
M M
U N
IC
A
TI
O
N
S
EC
U R
IT
Y
P
LA
N .D
R
E Y
, M
IC
H A
EL
A
B
C
D
E
F
2 3 4 5 6 7
N og al es
In te rn at io na l W as te w at er
T re at m en t P la nt
A dm in is tra tio n/ O
M
B ui ld in g
E . W as hi ng to n S tre et
, S ui te
P ho en ix , A
Z
P H
O N
E
2)
-3
F
A X
2)
-3
D
IA
G R
A M
C O
M M
U N
IC
A
TI
O
N R
IS
E
R
E-602
NOTES:
1. PROVIDE FLUSH MOUNTED FLOOR BOXES WITH DUPLEX RECEPTACLE,
TELEPHONE OUTLET, & NETWORK OUTLET
2. PROJECTOR VIDEO OUTLET
3. JUNCTION BOX ABOVE CEILING FOR PROJECTOR
4. WHERE MULTIPLE OUTLETS ARE SHOWN ADJACENT TO EACH OTHER,
OUTLETS MAT BE COMBINED IN SINGLE FACEPLATE ON SINGLE GANG
BOX
5. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL INFORMATION
& COMPONENTS
T
N
M
TELEPHONE OUTLET
NETWORK OUTLET
GB GLASS BREAK DETECTOR
MOTION SENSOR
DS DOOR SWITCH
PAGING SPEAKERS
CAMERAC
CR CARD READER
SYMBOLS:
EL ELECTRIC LOCK
H FIRE HORN/STROBE
PS FIRE PULL STATION
SMOKE DETECTOR
HD HEAT DETECTOR
DD DUCT DETECTOR
SD INTRUSION DETECTION
PUSHBUTTON STATION
S
ELECTRICAL CLOSET
S
MEN LOCKER
WOMEN LOCKER
S LAUNDRY
S CORRIDOR 2
S WORK BAY
T CONF
T CONF
T RECEPTION
T RECEPTION
T FAX
T PLOTTER
T SUPER
T OPERATOR
T OFFICE 1
T OFFICE 2
T WORK BAY
T FACP
PS
ELR
WORKBAY
PSWORKBAY
WORKBAY
WORKBAY
CORRIDOR 2
CORRIDOR 2 SD
LAUNDRY
CORRIDOR 1
SD
SD
HD
SD
PS
BACKDOOR PS
CORRIDOR 1 SD
FACP
MEN LOCKER
ELEC CLOSET
WOMEN LOCKER
PLOTTER
CONFSD
RECEPTION
FRONT DOOR
SD
SD
SD
SD
SD
SUPERSD
PS
H WORKBAY
H CORRIDOR 2
ELR
H TOILET
CORRIDOR 1
H RECEPTION MEN LOCKER
H EXTERIOR
120V
TELEPHONE
VIDEO RECORDER\SWITCHER
(LOCATED IN ELECTRICAL CLOSET)120V
120V
RECEPTION MONITOR
C
C
C
C GATE
WORK BAY
BACK DOOR
FRONT DOOR
SYSTEM CONTROL PANEL
(LOCATED IN ELECTRICAL CLOSET)
WORK BAYJ DS
J WORK BAY
J WORK BAYM
J SIDE DOORDS
J
J SD FRONT DOOR
TELEPHONE RISER
DIAGRAM
FIRE ALARM RISER
DIAGRAM
CCTV RISER
DIAGRAM
INTRUSION DETECTION
SYSTEM RISER DIAGRAM
DS
DS BACK DOOR
DS FRONT DOOR
J GB ENTRY
J GB CONFERENCE
J GB SUPER
J GB PLOTTER
J GB LEAD OP
J GB OFFICE 1
GB OFFICE 2
SD
TAMPER SWITCHS
FLOW SWITCHF
T RECEPTION
T RECEPTION
OFFICE 2
OFFICE 1
OPERATORSD
SD
SD
MEN LOCKERSD
CONFSD
WOMENLOCKER
H CORRIDOR 1
CONF
MEN LOCKER
C SIDE DOOR
ELR
MEN LOCKERSD
SL
SL
SL
SL
SL
SL STROBE LIGHT
Copyright: Tetra Tech w w w .te tra te ch .c om
M
AR
K D
A
TE
D
ES
C R
IP
TI
O N
BY
7/
/2
2:
:1
P
M
P :\0
\1
-0
-1
\C A
D \S
H E
E
TF
IL
E
S \E
-6
C O
M M
U N
IC
A
TI
O
N R
IS
E
R D
IA
G
R A
M .D
R
E Y
, M
IC
H A
EL
A
B
C
D
E
F
2 3 4 5 6 7
N og al es
In te rn at io na l W as te w at er
T re at m en t P la nt
A dm in is tra tio n/ O
M
B ui ld in g
E . W as hi ng to n S tre et
, S ui te
P ho en ix , A
Z
P H
O N
E
2)
-3
F
A X
2)
-3
Copyright: Tetra Tech w w w .te tra te ch .c om
M
AR
K D
A
TE
D
ES
C R
IP
TI
O N
BY
7/
/2
2:
:1
P
M
P :\0
\1
-0
-1
\C A
D \S
H E
E
TF
IL
E
S\ M
-0
H V
AC
L
E G
E N
D .D
R
E Y
, M
IC
H A
EL
A
B
C
D
E
F
2 3 4 5 6 7
N og al es
In te rn at io na l W as te w at er
T re at m en t P la nt
A dm in is tra tio n/ O
M
B ui ld in g
E . W as hi ng to n S tre et
, S ui te
P ho en ix , A
Z
P H
O N
E
2)
-3
F
A X
2)
-3
H
VA
C L
E G
E N
D
M-001
GENERATOR
OFFICE PLOTTER LEAD OPERATOR OFFICE 1 OFFICE 2 LAUNDRY
WORK BAY
CONFERENCE
ENTRY
CORRIDOR 1
WOMENS
MENS
JANITOR
CORRIDOR 2L-1
WC-1 L-1
WC-1
1-1/2" HW
BACKFLOW
PREVENTER
EWC-1
S-2
WASHER
2" CW
2" C
W
1- 1/
2" H
W
1- 1/
2" C
W
1-1/2" CW
3/4" HW 1" HW
3/4" CW
1-1/2" HW
L-1
2" CW
1"
HW
1/2" CW TO
ECU-1
BACKFLOW
PREVENTER
M-503
M-503
HB-1
S-2
2" CW
HB-1
1" CW
HB-1
HB-1
1" HW
2" FIRE LINE TO TIE
INTO AUTOMATIC
SPRINKLER SYSTEM
1" CW
2" C
W
TOILET
M-503
NOTE 1
NOTE 1
1/2" CW
CAU-1
3/4" HW
3/4" CW
3/8" CW
3/8" CW TO
REFRIGERATOR
ICE-MAKER
SEE NOTE 2
2" CW TO FIRE
SPRINKLER SYSTEM
DRYER
NOTE 4
NOTE 5
CONNECT TO EXST 4"
WATERLINE W/ TAPPING SLEEVE
1-1/2" CW
EWH-1
1-1/2" HW
NOTE 8
18"
MIN
18"
M
IN
SUPPORT 3/4" BLACK
IRON PIPE W / PIPE
HANGERS @ 4'-0" O.C
NOTE 7
3/4" BLACK
IRON PIPE
3/ 4"
C A
COMP AIR
VERTICAL
RUN DETAIL
(TYP 3)
M-503
Copyright: Tetra Tech w w w .te tra te ch .c om
M
AR
K D
A
TE
D
ES
C R
IP
TI
O N
BY
7/
/2
2:
:5
P
M
P :\0
\1
-0
-1
\C A
D \S
H E
E
TF
IL
ES
\M -1
P
LU
M
BI
N
G P
LA
N
.D
R E
Y , M
IC
H
A
EL
A
B
C
D
E
F
2 3 4 5 6 7
N og al es
In te rn at io na l W as te w at er
T re at m en t P la nt
A dm in is tra tio n/ O
M
B ui ld in g
E . W as hi ng to n S tre et
, S ui te
P ho en ix , A
Z
P H
O N
E
2)
-3
F
A X
2)
-3
P
LU
M B
IN
G
P
LA
N
M-101
N
PLAN
SCALE: 1/4"=1'-0"
1. TIE 1/2" CW LINE TO FLOOR DRAIN TRAP PRIMER
2. INSTALL THE TRAP PRIMING ASSEMBLY 24" AFF
3. REFER TO PLUMBING ISOMETRIC DRAWING M-501 FOR
FIXTURE SUPPLY SIZES
4. INCLUDE 4" DRYER VENT W/ CAP
5. INSTALL THE WATER LINE 6' ABOVE ELECTRICAL
EQUIPMENT
6. ALL HW SUPPLY PIPING TO BE INSULATED PER SECTION
220719
7. 3/4" NPT BLACK IRON PIPE CONNECTION TO AIR
COMPRESSOR W/ THREADED UNION @ COMPRESSOR AIR
DISCHARGE BALL VALVE.
8. SUPPORT 1/2" BLACK IRON PIPE VERTICAL DROP W/ P1000
UNISTRUT AND CONDUIT CLAMP @ 4'-0" O.C.
GENERAL NOTES:
(UNLESS OTHERWISE NOTED)
SST UNISTRUT PIPE
1 1/2"
FRONT ELEVATIONSIDE ELEVATION
2'-6"
FINISHED FLOOR
FINISHED FLOOR
SUPPORT (TYP.)
EXPANSION BOLT
INTO CONC WALL1'-0"1'-0"
3/4" FEMALE THREAD
1" SOLDER END BY
1" COPPER PIPE
CONC WALL
INTO WALL
EXPANSION BOLT
1" COPPER PIPE
3/4" ROTAMETER W/
3/4" BV
BU
BV NEEDLE VALVE
0-150 PSI
1/2"
G
0-150 PSI
BY-PASS
PRV
G
BV
S
3/4"
PUMP SEAL
NOTE:
3/4" BY-PASS
EACH PUMP REQUIRING SEAL WATER WILL BE PROVIDED W/ AN AVS
MOUNTED ON SST UNISTRUT ON THE PUMPS CONC PAD.
SIZE AS INDICATED
ON SCHEMATICS
10"
NOTE:
WITH 1/2" EXP BOLTS (TYP 4)
DRILL AND FASTEN TO CONC
WALL MOUNTED
7" R
4"
5"
8"
2" 2"
1'-6"
WELDED CONSTRUCTION ALL MATERIALS
NO 8 GA STL PL GALV AFTER FABRICATION
FS
CONNECTION
TO FIRE DEPT
TO SPRINKLER
SYSTEMTO 2" NPW
CONNECTION
TO SYSTEM
DRAIN
3' M
IN
FINISHED FLOOR
GRINNELL FIG 194-2
BRACKETS, w/ FIG 120
PIPE CLAMP (TYP 2)
PW SUPPLY
1/2" EXP BOLT
TO WALL (TYP 4)
WATTS SERIES 909QT, BRONZE
BODY AND MOUNTED, OR
APPROVED EQUAL *
* SIZE AS INDICATED ON SCHEMATIC
2" CW
1-1/2" HW
DRAIN VALVE
W / HOSE
CONNECTION
PRESSURE &
TEMP RELIEF
VALVE
DIELECTRIC
UNION (TYP)
80 GAL
WATER
HEATER
1-1/2" GATE VALVE
1-1/2" CW
INLET
(TYP)
1-1/2" GATE
VALVE (TYP)
INSTALL 3
8" AIR
QUICK RELEASE
BRASS FITTING
INSTALL INGERSOL
RAND REGULATOR
FOR 250 PSIG RATED
HEAVY DUTY SERVICE
12" DRIP LEG W
/1/2" THREADED
CAP
1/2" BLACK IRON
PIPE VERTICAL
LINE
3/4" BLACK IRON
PIPE AIR
DISTRIBUTION LINE
NOTE: SECURE W /
P1000 UNISTRUT
AND CONDUIT
CLAMP
M E
C H
A N
IC
A
L D
E
TA
IL
S
M-503
HOSE BIB MOUNTING DETAIL
NTS
HOSE RACK DETAIL
NTS
BACKFLOW PREVENTER DETAIL
NTS
COMPRESSED AIR VERTICAL DROP DETAIL
NTS
NOT USED
NTS
PRESSURE REDUCING STATION (PRS) DETAIL
NTS
AUTOMATIC VALVE STATION (AVS) DETAIL
NTS
FIRE SPRINKLER SYSTEM CONNECTION DETAIL
NTS
WATER HEATER PIPING SCHEMATIC DETAIL
SCALE 3"=1'-0"
Copyright: Tetra Tech w w w .te tra te ch .c om
M
AR
K D
A
TE
D
ES
C R
IP
TI
O N
BY
7/
/2
3:
:4
P
M
P :\0
\1
-0
-1
\C A
D \S
H E
E
TF
IL
E
S\ M
-5
M
EC
H A
N
IC
A L
D E
TA
IL
S .D
R
E Y
, M
IC
H A
EL
A
B
C
D
E
F
2 3 4 5 6 7
N og al es
In te rn at io na l W as te w at er
T re at m en t P la nt
A dm in is tra tio n/ O
M
B ui ld in g
E . W as hi ng to n S tre et
, S ui te
P ho en ix , A
Z
P H
O N
E
2)
-3
F
A X
2)
-3
| 01-COVER |
| 02-SA |
| 03-C-100 |
| 04-C-101 |
| 05-C-102 |
| 06-C-501R |
| 07-C-502R |
| 08-C-503 |
| 09-A-100 |
| 10-A-110 |
| 11-A-120 |
| 12-A-130 |
| 13-A-140 |
| 14-A-150 |
| 15-A-170 |
| 16-A-171 |
| 17-A-172 |
| 18-A-173 |
| 19-A-174 |
| 20-A-180R |
| 21-A-181 |
| 22-D-100 |
| 23-D-101 |
| 24-S-001 |
| 25-S-002 |
| 26-S-101 |
| 27-S-102 |
| 28-S-103 |
| 29-S-121 |
| 30-S-122 |
| 31-S-301 |
| 32-S-302 |
| 33-S-303 |
| 34-S-501 |
| 35-S-502 |
| 36-E-001R |
| 37-E-100 |
| 38-E-101R |
| 39-E-102R |
| 40-E-103 |
| 41-E-104R |
| 42-E-501 |
| 43-E-601 |
| 44-E-602R |
| 45-E-603 |
| 46-M-001R |
| 47-M-100 |
| 48-M-101R |
| 49-M-102 |
| 50-M-501 |
| 51-M-502 |
| 52-M-503R |
| 53-M-504 |
| 54-M-600 |