16Q0831_Required_CLIN_Structure.xlsx
XLSX spreadsheet 18 KB Posted
- Attached to
- Crystallization robot Federal contract opportunity
- Solicitation number
- HU0001-16-Q-0831
About this file
16Q0831 Required CLIN Structure
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 16Q0831_Provisions_and_Clauses_(P C).pdf | ||
| 16Q0831_Required_Provisions.docx | DOCX document | |
| 16Q0831_Request_for_Quote_(RFQ).pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. CLINs
| Request for Quote (RFQ) CLIN Structure 1/2 | ||||||
| Uniformed Services University (USU) | ||||||
| 16Q0831 Crystallization Robot | ||||||
| CLINs | Description | Quantity | Unit of Quanity | Unit Price | Extended Price | Total Price |
| 0001 | Crystallization robot (complete the second sheet of this spreadsheet "2. Desired Specs") | 1 | Each | 0.00 | ||
| 0002 | Delivery | 1 | Each | 0.00 | ||
| 0003 | Installation | 1 | Each | 0.00 | ||
| 0004 | Training | 1 | Each | 0.00 | ||
| 0005 | Extended warranty (up to five years) | 1 | Year | 0.00 |
0.00
2. Desired Specs
| Request for Quote (RFQ) CLIN Structure 2/2 | ||
| Uniformed Services University (USU) | ||
| 16Q0831 Crystallization Robot | ||
| CLIN 0001 Crystallization Robot | ||
| Desired Specification | Quoted Specification | Reference Page No. in the Quote Package/Product Literature |
| 1. Desired Specifications | ||
| 1.a. Multiple lab ware positions to simultaneously accommodate multiple deep well blocks (crystallization solutions and additive solutions) and multiple crystallization plates. | ||
| 1.b. Dispenses crystal screen solutions from deep well blocks to crystallization plate and sets up crystallization drops both in a single operation. | ||
| 1.c. Sets up crystallization plates rapidly to minimize evaporation of drops. | ||
| 1.d. Delivers crystallization solutions accurately, <5% CV, from 0.1 ml to 100 ml. | ||
| 1.e. Delivers protein samples accurately, <5% CV, at a volume as low as 0.1 ml. | ||
| 1.f. Air-driven delivery of protein samples preferred to avoid mixing or diluting samples. | ||
| 1.g. Takes enough protein in one operation to deliver to the entire plate to avoid constant agitation of the protein sample or slow dispensing. | ||
| 1.h. Keeps temperature-sensitive samples (proteins) cool while dispensing. | ||
| 1.i. Non-contact dispensing of protein samples to avoid cross contamination. | ||
| 1.j. Ability to pipet liquids of different viscosity accurately by easily adjusting machine parameters (e.g. programmable liquid classes). | ||
| 2. Warranty Period | ||
| 3. Country of Manufacture |
File details come from the government source that posted it. Updated .