Attachment 11 A Mobile Tablet Requirements.pdf

PDF 203 KB Posted

Attached to
Housing Inspection Services Federal contract opportunity
Solicitation number
HSFE80-12-R-0033
Issued by
Federal Emergency Management Agency Recovery Section

About this file

Attachment 11 A Mobile Tablet Requirements

View the file

Other files for this federal contract opportunity

Other files attached to Housing Inspection Services, newest first.
File Type Posted
HSFE80-12-R-0033_0005.pdf PDF
HSFE80-12-R-0033_0004.pdf PDF
SOLICITATION_QA_POSTING_10232012.pdf PDF
SOLICITATION_QA_POSTING_10222012.pdf PDF
Attachment_22_Production_Update_Format.xlsx XLSX spreadsheet
Attachment_17_Operations_Costs_Model.pdf PDF
Attachment_15_Performance_Requirements_Summary_Matrix.pdf PDF
Attachment_2_Performance_Requirement_Summary.pdf PDF
Attachment_17_Operations_Costs_Model_LIVE_101612.xlsx XLSX spreadsheet
Attachment_4_Deliverables.pdf PDF
SOLICITATION_QA_POSTING_10192012.pdf PDF
Attachment_17_Operations_Costs_Model_LIVE_101612.xlsx XLSX spreadsheet
SOLICITATION_QA_POSTING_100312(3).pdf PDF
SOLICITATION_QA_POSTING_100312.pdf PDF
SOLICITATION_QA_POSTING_100212.pdf PDF
Attachment_17_Operations_Costs_Model.docx DOCX document
SOLICITATION_QA_POSTING_9212012(2).pdf PDF
SOLICITATION_QA_POSTING_9212012.pdf PDF
Attachment 17 Operations Costs Model LIVE.xlsx XLSX spreadsheet
HSFE80-12-R-0033 0001.pdf PDF
Attachment 17 Operations Costs Model.pdf PDF
Attachment 16 Inspection Invoice Template.pdf PDF
Attachment 23 Nationwide Wage Determination No 1995-0221.pdf PDF
Attachment 9 B 009-0-4 Declaration and Release form Spanish former 90-69C.pdf PDF
Attachment 18 Past Performance Questionnaire Template.doc DOC document
Attachment 10 Automatic FEMA Corrections.pdf PDF
Attachment 7 IHP Inspection Guidelines Template.docx DOCX document
Attachment 2 Performance Requirement Summary.pdf PDF
Attachment 22 Production Update Format.xlsx XLSX spreadsheet
Attachment 5 A English Customer Service Survey.doc DOC document
Attachment 15 Performance Requirements Summary Matrix.xlsx XLSX spreadsheet
Attachment 14 FEMA Forms for Property.pdf PDF
HSFE80-12-R-0033 HIS RFP.pdf PDF
Attachment 9 A 009-0-3 Declaration and Release Form English former 90-69Bfbo.pdf PDF
Attachment 17 Operations Costs Model fbo.pdf PDF
Attachment 8 Shelter IHP Inspection Guidelines fbo.pdf PDF
Attachment 3 DHS Handbook fbo.pdf PDF
Attachment 4 Deliverables fbo.pdf PDF
Attachment 2 Performance Requirement Summary fbo.pdf PDF
Attachment 20 FEMA Post Travel Expense Summary fbo.pdf PDF
Attachment 6 Privacy Awareness Training fbo.pdf PDF
Attachment 10 Automatic FEMA Corrections fbo.pdf PDF
Attachment 5 A English Customer Service Survey fbo.pdf PDF
Attachment 11 B Mobile Device Rules of Behavior User Agreement fbo.pdf PDF
HSFE80-12-R-0033 HIS RFP.pdf PDF
Attachment 21 HIS History fbo.pdf PDF
Attachment 18 Past Performance Questionnaire Template fbo.pdf PDF
Attachment 16 Inspection Invoice Template fbo.pdf PDF
Attachment 11 A Mobile Tablet Requirements fbo.pdf PDF
Attachment 19 FEMA Travel Mileage Log fbo.pdf PDF
Show all 50

Housing Inspection Services has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 11 A Tablet Requirements Page 1 of 2

Mobile Tablet Selection Requirements

1.1 Hardware Specifications

The mobile unit MUST at a MINIMUM meet/contain the following specifications:

1.1.1.1 Android 3.0 operating system

1.1.1.2 Size not to exceed 10.1” (H) x 6.9” (W) x .5” (D)

1.1.1.3 Weight not to exceed 1.61 lbs

1.1.1.4 10.1” WXGA display/1280x800 resolution/149 pixels per inch (ppi)

1.1.1.5 1GHz dual core processor

1.1.1.6 1GB low power internal RAM

1.1.1.7 32GB internal memory/storage

1.1.1.8 Communication capabilities MUST support:

1.1.1.8.1 3G

1.1.1.8.2 Wifi 802.11a/b/g/n

1.1.1.8.3 Bluetooth

1.1.1.9 Assisted GPS (aGPS) (GPS functionality independent of the cell service)

1.1.1.10 3MP auto‐focus rear camera with video capture capable of 720p

1.1.1.11 Built‐in microphone

1.1.1.12 Sensors MUST include:

1.1.1.12.1 Gyroscope

1.1.1.12.2 Accelerometer

1.1.1.12.3 Ambient light sensor

1.1.1.13 Battery capable of sustaining up to 9 hours of continued use

Attachment 11 A Tablet Requirements Page 2 of 2

1.2 Required Software

1.2.1.1 Android 3.0 (Honeycomb) operating system

1.2.1.2 Each tablet MUST also have a Mobile Device Management (MDM) application installed or license purchased. FEMA IT/ITSEC has approved the use of the Good for Enterprise solution. (This is a per unit license (Client Access License (CAL)) cost and MUST be purchased/provided with each unit.)

This license will allow FEMA IT/ITSEC to set and manage the device security policies and permissions.

PLEASE NOTE: In order to establish a connection with FEMA to communicate the data collected in the field this license must be purchased.

1.3 Additional Requirements

1.3.1.1 The tablet units MUST be able to be connected/joined to a data service carrier (e.g. Verizon, AT&T, etc.).

1.3.1.2 Each tablet MUST have a protective cover

1.3.1.3 Each tablet MUST have a screen protector/anti‐glare cover

1.3.1.4 Each tablet MUST have an external power supply/power cord

1.3.1.5 All employees and contractors must read, adhere to and sign “FEMA Rules of Behavior for

Mobile Devices” (Att. 11 b) prior to using a mobile device and return to the COR or alternate.

*Specified brands TBD by FEMA.