Attachment 10 Automatic FEMA Corrections fbo.pdf

PDF 20 KB Posted

Attached to
Housing Inspection Services Federal contract opportunity
Solicitation number
HSFE80-12-R-0033
Issued by
Federal Emergency Management Agency Recovery Section

About this file

Attachment 10 Automatic FEMA Corrections

View the file

Other files for this federal contract opportunity

Other files attached to Housing Inspection Services, newest first.
File Type Posted
HSFE80-12-R-0033_0005.pdf PDF
HSFE80-12-R-0033_0004.pdf PDF
SOLICITATION_QA_POSTING_10232012.pdf PDF
SOLICITATION_QA_POSTING_10222012.pdf PDF
Attachment_17_Operations_Costs_Model.pdf PDF
Attachment_15_Performance_Requirements_Summary_Matrix.pdf PDF
Attachment_2_Performance_Requirement_Summary.pdf PDF
Attachment_17_Operations_Costs_Model_LIVE_101612.xlsx XLSX spreadsheet
Attachment_22_Production_Update_Format.xlsx XLSX spreadsheet
Attachment_4_Deliverables.pdf PDF
SOLICITATION_QA_POSTING_10192012.pdf PDF
Attachment_17_Operations_Costs_Model_LIVE_101612.xlsx XLSX spreadsheet
SOLICITATION_QA_POSTING_100312(3).pdf PDF
SOLICITATION_QA_POSTING_100312.pdf PDF
SOLICITATION_QA_POSTING_100212.pdf PDF
Attachment_17_Operations_Costs_Model.docx DOCX document
SOLICITATION_QA_POSTING_9212012(2).pdf PDF
SOLICITATION_QA_POSTING_9212012.pdf PDF
Attachment 17 Operations Costs Model LIVE.xlsx XLSX spreadsheet
HSFE80-12-R-0033 0001.pdf PDF
Attachment 17 Operations Costs Model.pdf PDF
Attachment 2 Performance Requirement Summary.pdf PDF
Attachment 22 Production Update Format.xlsx XLSX spreadsheet
Attachment 16 Inspection Invoice Template.pdf PDF
Attachment 23 Nationwide Wage Determination No 1995-0221.pdf PDF
Attachment 9 B 009-0-4 Declaration and Release form Spanish former 90-69C.pdf PDF
Attachment 18 Past Performance Questionnaire Template.doc DOC document
Attachment 10 Automatic FEMA Corrections.pdf PDF
Attachment 7 IHP Inspection Guidelines Template.docx DOCX document
Attachment 5 A English Customer Service Survey.doc DOC document
Attachment 15 Performance Requirements Summary Matrix.xlsx XLSX spreadsheet
Attachment 14 FEMA Forms for Property.pdf PDF
HSFE80-12-R-0033 HIS RFP.pdf PDF
Attachment 5 A English Customer Service Survey fbo.pdf PDF
Attachment 11 B Mobile Device Rules of Behavior User Agreement fbo.pdf PDF
HSFE80-12-R-0033 HIS RFP.pdf PDF
Attachment 21 HIS History fbo.pdf PDF
Attachment 9 A 009-0-3 Declaration and Release Form English former 90-69Bfbo.pdf PDF
Attachment 17 Operations Costs Model fbo.pdf PDF
Attachment 8 Shelter IHP Inspection Guidelines fbo.pdf PDF
Attachment 3 DHS Handbook fbo.pdf PDF
Attachment 4 Deliverables fbo.pdf PDF
Attachment 2 Performance Requirement Summary fbo.pdf PDF
Attachment 20 FEMA Post Travel Expense Summary fbo.pdf PDF
Attachment 6 Privacy Awareness Training fbo.pdf PDF
Attachment 18 Past Performance Questionnaire Template fbo.pdf PDF
Attachment 16 Inspection Invoice Template fbo.pdf PDF
Attachment 11 A Mobile Tablet Requirements fbo.pdf PDF
Attachment 19 FEMA Travel Mileage Log fbo.pdf PDF
Attachment 5 B Spanish Customer Service Survey fbo.pdf PDF
Show all 50

Housing Inspection Services has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 10

Federal Emergency Management Agency Housing Inspection Services Virginia National Processing Services Center Winchester, VA 22603

Attachment 10 Automatic FEMA Corrections.docxPage 1 of 2 01/27/2010

Automatic FEMA Corrections

January 2010

The following listed errors will be used for correcting inspections identified through the field Quality Control process conducted by contracted or Federal staff. Inspections noting one or more errors will be returned as FEMA Corrections (FCOR).

1. Inspector did not correct the registrant’s name, addresses or primary contact number when indicated by the applicant at the time of inspection.

2. Inspector did not record or correct the insurance type at the time of inspection.

3. Inspector failed to correctly obtain a signed 9069 when performing a complete inspection.

4. Inspector failed to record a disaster related clothing need, and or recorded a clothing loss when there was no need.

5. Inspector failed to record the correct number of bedrooms occupied by the applicant and household members.

6. Inspector did not record all destroyed and repairable vehicles owned by the applicant and household members. And/or, the inspector failed to record one additional non-damaged vehicle when one was available or noted by the applicant or a household member.

7. Inspector destroyed the dwelling when clearly should have used line items and specified damages.

8. Inspector failed to record all essential like-kind rooms. Example: Inspector recorded one

Living Room as repair but did not record the undamaged Living Room.

9. Inspector did not verify occupancy through an approved document, or used an invalid document (i.e. drivers license with a different address than that of the DD), or failed to speak with the landlord, or failed to comment on his attempt to verify with a utility provider, or failed to comment about exhausting all means to verify. And/or, the inspector listed occupancy as “Not Verified” and did not provide the required comment.

10. Inspector did not verify ownership through an approved document, or used an invalid document (Tax Bill in another person’s name), or failed to call the tax office, or failed to make a second site visit to allow the applicant time to provide proper documents, or failed to comment about exhausting all means to verify.

11. Inspector failed to record a required comment.

Attachment 10

Federal Emergency Management Agency Housing Inspection Services Virginia National Processing Services Center Winchester, VA 22603

Attachment 10 Automatic FEMA Corrections.docxPage 2 of 2 01/27/2010

12. Inspector recorded Habitability Repairs Required incorrectly

13. Inspector recorded a variance in the size of residence by more than 10% and the measurement is used to determine associated specifications (i.e. speed estimating in flooding events used to determine interior damages from the floor area).

14. Inspector failed to select an applicant indicated Medical, Dental, Funeral, Other, Transportation, Essential Tool and/or Moving & Storage need.

15. Inspector recorded Inaccessibility incorrectly.

16. Inspector recorded Utilities Out incorrectly.

17. Inspector’s cumulative differences from missed, excessive or by recording a wrong cause of damage for real and personal property exceeding $500 will be returned for correction. The threshold is based on the fiscal year national low price and includes all specs with an associated dollar amount.

a. For example: the inspector failed to record $100 of exterior wall damaged, listed $550 in roof covering damaged by flood but was damaged by Wind, and recorded a $250 dehumidifier purchased outside the eligible time-period, would aggregate a $900 error.

File details come from the government source that posted it. Updated .