AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

1. CONTRACT ID CODE

PAGE OF PAGES

1 2

2. AMENDMENT/MODIFICATION NO.

3. EFFECTIVE DATE

08/01/2016

4. REQUISITION/PURCHASE REQ. NO.

5. PROJECT NO. (If applicable)

6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE

Contracting Officer, CEU Providence Contracting/Inspection 475 Kilvert St. Suite 100 Warwick, Rhode Island 02886

G. J. Fortin Contracting Officer

(508) 968-6499 CEU Providence, Warwick, RI

8. NAME AND ADDRESS OF CONTRACTOR (NO., STREET, COUNTY, STATE AND ZIP CODE)

THIS AMENDMENT MUST BE ACKNOWLEDGED

9A. AMENDMENT OF SOLICITATION NO.

HSCGG1-16-B-PRV188

9B. DATED (SEE ITEM 11)

07/05/2016

10A. MODIFICATION OF CONTRACT/ORDER NO.

CODE FACILITY CODE

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

[X] The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers [ ] is extended, is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing Items 8 and 15, and returning 001 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE REFERENCED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET

FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (SPECIFY TYPE OF MODIFICATION AND AUTHORITY)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

Solicitation HSCGG1-16-B-PRV188 identified in Block 9A, for Repairs to CG Station Brant Point, Nantucket, MA, is amended as follows.

1. See attached questions/answers.

2. The due date for the proposal is not extended.

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or Print)

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

G. J. Fortin, Contracting Officer

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

15C. DATE SIGNED

16B UNITED STATES OF AMERICA

BY

(Signature of Contracting Officer)

16C. DATE SIGNED

Question: In the specifications section 01 11 00 Summary of Work, there are several instances in the base bid description of work where it references providing new wood stud walls. However, on the contract drawings, detail B1 on sheet A601, it shows all of the different partition types being of metal stud construction. Which is correct?

CEU Response: All new interior walls shall be metal stud construction.

Question: On drawing pages C101, C102, Pages 6 & 7 of 63, Revision #1, 6/6/16, for HSCGG1-16-B-PRV188, Major Repairs to Brant Point, there is a site plan and an elevation and accompanying details for an operable security fence. However, in the Specifications, Table of Contents, there is no CSI Master Format Division 32 31 16 "WELDED WIRE FENCES & GATES" section or 32 31 26 "WIRE FENCES & GATES" section included. It appears that the only information to further develop this scope of work without a referenced manufacturer as a performance standard for the bidder to work towards is on the drawings.

Also, Note #8 schedules signs to be affixed to the fence, what signs, how many, what do they state?

CEU Response: The fencing in question is covered by specification section 32 31 13.53 "High Security Chain-Link Fences and Gates". There are no signs that will be affixed to the fence.

Question: I noticed in the specifications section 08 52 00 that the new windows are simply designated “WOOD WINDOWS”.

Is it the Coast Guard’s intent not to install any type of clad window with the appropriate Impact Zone 3 protection?

CEU Response: See attached revised specification section 08 52 00.

Question: Specification Section 01 11 00 Page 3 Bid Option #2A-MMB-Replace Exterior Windows specifies that "All exterior work is subject to the guidelines set forth by the State Historic Preservation Office (SHPO).

Refer to the Paragraph 2: Historic Facilities." Where is this document in the bid documents please?

CEU Response: The USCG has since secured State Historic Preservation Office (SHPO) approval to replace "in-kind" for all exterior work. Contractor shall comply with the project plans and specification.

One of the vendors that is furnishing the shore ties has a concern about the available space, specifically for the 480V shore tie.

His question is: "Please verify what the available footprint is for the replacement 480V power mound called out in Bid Option #6?"

CEU Response: This will not be a shore-tie installed within what we call a power mound. This should be a single 480VAC (tapped to 450VAC) receptacle installed on the railing as is the existing. Any additional information will need to be field verified.

DEPARTMENT OF HOMELAND SECURITY

MAJOR REPAIRS USCG STATION BRANT POINT

SECTION 08 52 00

WOOD WINDOWS

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

AAMA/WDMA/CSA 101/I.S.2/A440 (2011) Standard/Specification for Windows, Doors, and Skylights

U.S. ENVIRONMENTAL PROTECTION AGENCY (EPA)

Energy Star (1992; R 2006) Energy Star Energy Efficiency Labeling System (FEMP)

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Wood Windows; G, COR

Indicate elevations of units, full-size sections, fastenings, methods of installation and anchorage, method of glazing, locations of operating hardware, mullion details, method and material for weatherstripping, bar and muntin layouts, method of attaching, details of installation, and connections with other work.

SD-03 Product Data

Wood Windows; G, COR

Engineered Wood Products

Submit documentation verifying that no urea-formaldehyde resins were used.

Fasteners

Adhesives

SD-08 Manufacturer's Instructions

Wood Windows

SECTION 08 52 00 Page 1

Submit manufacturer's written instructions for installation.

SD-10 Operation and Maintenance Data

Wood Windows, Data Package 1; G, COR

SD-11 Closeout Submittals

Energy Efficient Equipment for Residential Windows; S

1.3 DELIVERY AND STORAGE

Deliver windows to site in sealed undamaged cartons or in palletized multiple units. Protect from damage, dampness and extreme temperature or humidity changes. Store under cover in well-ventilated enclosed space.

Do not store in a building under construction until concrete, masonry, and plaster are dry. Replace defective or damaged windows.

PART 2 PRODUCTS

2.1 MATERIALS

2.2 WOOD WINDOWS

Wood windows must consist of complete units including sash, glass, frame, weatherstripping, insect screen, and hardware. Window units must meet the Grade 40 requirements of AAMA/WDMA/CSA 101/I.S.2/A440, except maximum air infiltration must not exceed 0.34 CFM per linear foot of sash crack when tested under uniform static air pressure difference of 1.57 psf.

Residential glazed systems (including frames and glass) must be Energy Star qualified products as appropriate to North/Central climate zone. In addition to general hardware requirements of AAMA/WDMA/CSA 101/I.S.2/A440, provide hardware for various window types as indicated below. Wood members which will receive transparent finish must be in one piece, not finger-jointed.

Wood windows shall meet the following criteria:

Wind loads applied in accordance with the Building Code herein.

Basic Wind Speed, V = 120 mph (3-second gust, service wind) using 780 CMR and ASCE 7.

Wind Exposure D.

Wind Importance Factor of IV.

2.2.1 Single-Hung and Double-Hung Windows

Provide with one sash fastener and two sash lifts, except provide one sash lift when window is fitted with a balance that counterbalances weight of sash.

2.2.2 Awning Windows (Top Hinged)

Awning window ventilators in same bay must operate separately. Provide two or more hinges, pivots, or sash-supporting arms for each operative sash to allow easy operation, substantial support and cleaning of both

SECTION 08 52 00 Page 2 sides of sash from inside. Provide latches for securing each sash if operating devices do not include locking features. Provide operating devices for controlling position of sash, including full open, tight close, and intermediate firm hold. Provide operating devices with rotary operators of worm-gear type with wear-resistant and impact-resistant gears or lever operators of lever handle, off-set arm type. Provide venting sash with corrosion resistant steel hinges connected to top and bottom rails of sash. When lever operators are used, operating arms must be adjustable so that even sash edge contact can be maintained. Provide compression-type weatherstripping.

2.3 ACCESSORIES

2.3.1 Adhesives

Comply with applicable regulations regarding toxic and hazardous materials, and as specified in Section 07 92 00 JOINT SEALANTS. For interior application of joint sealants comply with applicable regulations regarding reduced VOC's as specified in Section 07 92 00 JOINT SEALANTS.

2.3.2 Fasteners

Provide fastener types as standard with the window manufacturer for windows, trim, and accessories.

2.4 FINISHES

2.4.1 Paint

Furnish windows with factory-primed surfaces which will be exempt from first paint coat application required in Section 09 90 00 PAINTS AND

COATINGS.

PART 3 EXECUTION

3.1 INSTALLATION

Any materials that show visual evidence of biological growth due to the presence of moisture must not be installed on the building project.

3.1.1 Wood and Wood Clad Windows

Install in accordance with the approved installation instructions.

Securely anchor windows in place. Install and seal windows in a manner that will prevent entrance of water and wind.

3.2 ADJUSTMENTS

Make final adjustment for proper operation of ventilating unit after glazing. Make adjustments to operating sash or ventilators to assure smooth operation. Units must be weathertight when locked closed. Verify products are properly installed, connected, and adjusted.

3.3 CLEANING

Clean windows on both exterior and interior in accordance with manufacturer's recommendations.

-- End of Section --