Questions-Answers_02.docx
DOCX document 17 KB Posted
- Attached to
- CGC PATOKA FY14 Dry-dock & Repairs
- Solicitation number
- HSCG85-14-Q-P45D83
About this file
Question and Answer for Amendment 00002 to Dry-dock Repairs of CGC PATOKA
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 0004_SF30.docx | DOCX document | |
| 00003_SF30.docx | DOCX document | |
| Questions-Answers_03.docx | DOCX document | |
| 00002_SF30.docx | DOCX document | |
| Questions-Answers_01.docx | DOCX document | |
| 00001_SF30.docx | DOCX document | |
| coating_report.pdf | ||
| PATOKA_(WLR_75E)_DD_AHS_14R0.docx | DOCX document | |
| GOVERNMENT_PROPERTY_REPORT.docx | DOCX document | |
| Request_for_Clarification.docx | DOCX document | |
| SOLCITATION_FOR_CGC_PATOKA_DD.docx | DOCX document | |
| PATOKA_(WLR_75E)_DD_AHS_14R0.docx | DOCX document | |
| SOLCITATION_FOR_CGC_PATOKA_DD.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
| Request for Quote | HSCG85-14-Q-P45D83 | |
| DRY-DOCK & REPAIRS OF CGC PATOKA (WLR-75408) | Amendment 0002 |
A. Questions/Answers to Request for Clarification with regards to dry-dock & repairs of CGC PATOKA (WLR-75408 )
0001 Question: D-31 Dry-docking – Barge, The specification draft states 5’-7 13/16. The curves of form only cover the draft up to 5 feet. Specification displacement is 442.69 long tons, which is also outside of the curves of form. Please confirm the correct version of the curves of form document?
Answer: Please use a draft of 4.25 feet and a displacement of approximately 250 long tons in seawater.
B. This Solicitation is not extended.
NOTES: ACKNOWLEDGE RECEIPT OF ALL AMENDMENTS IN PROPOSALS.
A. THE SOLICITATION PERIOD IS NOT EXTENDED.
B. ALL OTHER TERMS AND CONDITIONS CITED IN THE ORIGINAL SOLICITATION REMAIN THE SAME.