HSCG40-16-Q-P30E03_A00001_(continued).pdf

PDF 438 KB Posted

Attached to
USCG STA SHINNECOCK (47233) 2016 DRYDOCK REPAIRS
Solicitation number
HSCG40-16-Q-P30E03
Issued by

About this file

HSCG40-16-Q-P30E03 A00001 (Continued).

View the file

Other files

File Type Posted
IMG_7688.jpg JPG image
IMG_1642.JPG JPG image
Drop_Down_Grate_(2).JPG JPG image
IMG_1636.JPG JPG image
IMG_7695.jpg JPG image
IMG_7689.jpg JPG image
IMG_7691.jpg JPG image
Helm_Box.JPG JPG image
IMG_7692.jpg JPG image
IMG_7693.jpg JPG image
IMG_7585.jpg JPG image
IMG_1641.JPG JPG image
IMG_7690.jpg JPG image
IMG_7694.jpg JPG image
IMG_7687.jpg JPG image
IMG_7584.jpg JPG image
IMG_1634.JPG JPG image
HSCG40-16-Q-P30E03_A00001_SF30.pdf PDF
IMG_7628.jpg JPG image
IMG_7627.jpg JPG image
47233_(MLB_47)_DD_FQ4_ANP_16R0.pdf PDF
COMBINED_SYNOPSIS_SOLICITATION_HSCG40-16-Q-P30E03.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HSCG40-16-Q-P30E03

Amendment Number A00001

14A. This Amendment is issued to answer the following questions submitted in response to this solicitation:

WORK ITEM D-001 General Welding, Provide.

Question 1. 3.2.1 – Port Side Forward Drop Down Tab: No drawings are listed for this one and there is no part shown in general drawings for a “drop down tab,” please provide more information.

Answer. Pictures of drop down tabs are attached and available for download. Tab is approximately 4" x 2 1/2" bent at a 90 deg angle with one hole drilled to accommodate a locking pin.

Question 2. 3.2.2 – Temporary Gusset / Fuel Sounding Rod: Please provide drawings and/or more information.

Answer. Fuel sounding rod has crack at weld, and when inserted into sounding tube the rod goes deeper than it should, indicating a worn striker plate in fuel tank. Reference: Drawing 47MLB 505-20

Question 3. 3.2.4 – Bridge Console: How many holes need to be welded and re-drilled?

Answer. Approximately 10 holes. Holes need to be clad welded closed and re-drilled. Pictures attached and available for download.

Question 4. Port Side Drop Down Grate: Please provide construction drawings.

Answer. Pictures attached and available for download.

HSCG40-16-Q-P30E03

Amendment Number A00001

Question 5. HVAC Strainer: Can you provide a picture or drawing of the area to be “reconfigured?” there is not enough information to estimate by.

Answer. HVAC Strainer base contacts the framing below strainer causing severe corrosion. Strainer mounting plate will need to be cropped or strainer mounting plate re-drilled to and moved to prevent strainer from touching frame below. Pictures attached and available for download.

Question 6. 3.2.8 – Bridge Window: States to seal IAW ref drawings;

no drawings are provided showing the bridge windows.

Answer. STBD side fwd window was replaced a couple of years ago and the bolt hole mounting pattern was different. New holes were drilled to accommodate installing the new window. The window will need to be removed, all unused holes clad welded and the window re-mounted using the correct bolt pattern holes. Pictures attached and available for download.

Question 7. 3.2.9 – Helm Box: States to fabricate and install new helm box IAW ref drawings; no drawings are provided showing the helm box construction.

Answer. Reference: Drawing 47B 438-10. Pictures attached and available for download.

14B. The date and time established for receipt of proposals remains May 27, 2016 at 12:00 PM EST. All other terms and conditions remain unchanged.

(END OF AMENDMENT NUMBER A00001)