14A. This Amendment is issued to answer the following questions submitted in response to this solicitation:

Question 2: Work Item D-012. Propulsion Shaft, Remove, Inspect, and Install. Paragraph

3.6 NDE. NDI dye-pen has been used in past, has this been changed, is dye-pen still an acceptable inspection method?

Answer: Dye-pen is an acceptable NDE/NDI (non-destructive examination/non-destructive inspection)

Question 3: Work Item D-015. Standard Hoses, Renew. Paragraph 3.2.3. Do the procedures remain for using the FC-234 and FC-355 Aeroquip Hose, which was reusable hose fittings only and no miss matching of the brands (Aeroquip hose to Aeroquip reusable hose ends only)? Are the FC-355 hose the -20 size only, as the FC-234 is not made in -20 size? Will there be a change request if the sizes of the hoses and lengths are incorrect?

Answer: Review General Note 66 on sheet 16 of CG drawing 47B MLB 505-020. No mismatching of fittings is allowed. Any changes, including but not limited to incorrect hose length, shall be handled via the Change Request process.

Question 4: Work Item D-018. Sea Strainers – Simplex (All Sizes), Clean and Inspect.

Paragraph 3.2.3. Can contractor renew with in-kind materials if needed?

Answer: Yes, renew in-kind.

14B. The date and time established for receipt of proposals remains March 02, 2016 at

12:00 PM EST.

All other terms and conditions remain unchanged.

(END OF AMENDMENT NUMBER A00002)