Attachment 1 - Specification number SP-PPM-001 REV D dated 05/10 entitled Preservation Packaging Marking

View the file

Other files for this federal contract opportunity

Other files attached to Johnston Boiler, newest first.
File Type Posted
JOTFOC.pdf PDF
Attachment_1.pdf PDF
Attachment_2.pdf PDF
Combined_Synopsis-Solicitation_Johnston_Boiler_HSCG40-14-R-30011.docx DOCX document
Attachment_2.pdf PDF
Combined_Synopsis-Solicitation_Johnston_Boiler_HSCG40-14-R-30011.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USCG /SFLC SP-PP&M-00l DATED 05/95 REVISION D 05/10

PRESERVATION, PACKAGING & MARKING

PRESERVATION – Each piece or assembly that makes up one each of any contract line item (CLIN) shall be preserved in accordance with ASTM-D-3951.

PACKAGING – Each preserved contract line item shall be packed in its’ own carton or box as needed to meet the requirements of ASTM-D-3951. This package shall be considered a unit pack. This unit pack shall meet the requirements of a shipping container.

UNITIZATION – Unit packs can be unitized as specified in

ASTM-D 3951.

MARKING – Marking shall be clear, legible, permanent, and in English.

UNIT PACKAGES – Shall be marked as specified herein.

National Stock Number/Activity Control Number.

Item Name Part Number (as shipped) Purchase Order / Contract Number Date of Manufacturer/Repair The Words “COAST GUARD SFLC MATERIAL”CONDITION (A) Quantity & Unit of Issue (i.e. “1-EA”)

Hazardous Material Marking (As required in Code of Federal Regulations (CFR) section 4).

Flash Point (If item is a liquid with a flash point of

93.3 degrees C (200 Degrees F) or less.)

Propellant Chemical Name (Aerosol Containers only).

UNITIZATION - If unitization is used as the final shipping container the unitized pack for one stock number shall be marked as specified below, see “Single Stock Number” If there are multiple stock numbers involved see“Multiple Stock Numbers” herein.

For no reason shall more then one purchase/delivery order be unitized together.

Single Stock Number National Stock Number/ Activity Control Number.

Purchase Order / Contract Number The Words “COAST GUARD SFLC MATERIAL”CONDITION (A).

Quantity & Unit of Issue (i.e. “1-EA”)

Hazardous Material Marking (If needed and as required in Code of Federal Regulations (CFR) section 4).

Flash Point (If item is a liquid with a flash point of 93.3 degrees C (200 Degrees F) or less.).

The Words “COAST GUARD SFLC MATERIAL” “MULTIPACK”

Attachment 1

Multiple Stock Numbers

“ALL”National Stock Numbers/Activity Control Numbers.

Purchase Order / Contract Number The Words “COAST GUARD SFLC MATERIAL” CONDITION (A).

Quantity & Unit of Issue (i.e. “1-EA”) Hazardous Material Marking (If needed and as required in Code of Federal Regulations (CFR) section 4).

Flash Point (If item is a liquid with a flash point of

93.3 degrees C (200 Degrees F) or less.).

The Words “COAST GUARD SFLC MATERIAL” “MULTIPACK”

BAR CODING – All bar coding required herein shall be Code 39, also called Code 3 of 9 in accordance with ANSI/AIM BC1. ALL Stock numbered items shall be bar coded.

a. The standard marking required in MARKING for all for all packaging configurations can be applied separately or as part of the Bar Code Label. If the latter option is used the label size shall be adjusted appropriately.

b. The stock number or numbers, and purchase order

/ contract number shall be bar coded with Human Readable Interpretation (HRI) immediately below the bar coding on unit and unitized packs.

c. All HRI shall be placed below its associated bar code.

The label shall be intended for long-term indoor applications where the labels will endure intermittent outdoor exposure. Each label shall be for porous surfaces and consist of paper without plastic laminate.