The file's text, extracted by GovTribe without its formatting.
HSCG38-12-Q-200102 Requirements
1.0 Statement of Need.
This requirement is for the acquisition of one (1) Sanding Booth to be used by the Aviation Logistics Center. The Sanding Booth will be used to provide a cleaner, safer, and healthier work environment by capturing hazardous dust particles (Kevlar, Carbon, Hexavalent Chromium, etc.) during grinding and sanding operations on composite aircraft parts and assemblies. The contractor shall provide the Sanding Booth at the firm fixed price(s) specified in the resultant Purchase Order.
2.0 Requirements.
| Dimensions |
| 20’ Long x 8’ Deep x 8’ Tall – not to exceed 9 1/2 feet outside dimensions |
| Opening |
| 3 sided with open front being 20’ Long |
| Air System |
| Regain Air System in each module |
| Motors |
| 5hp TEFC new GE Energy Saver HE motors |
| Blower |
| Direct Drive, high capacity, non-sparking, backwards inclined, Class II |
| Airflow |
| Blower – 6000 CFM airflow rating |
| Motor Starter |
| Factory fitted premium brand manual motor starter with push button on/off. Overload in NEMA rate enclosure |
| Filter |
| True Hepa filter system |
| Cleaning System |
| Power Pulse type electronic filter cleaning system with 24 timer control with optional switch for manual activation of pulse control |
| Draw |
| Positive-sealing high-capacity removable draws |
| Lighting |
| Dust Tight – UL 844 Hazardous Area compliant |
| Finish |
| Blue Industrial Enamel anti-corrosive through out |
| Gauge |
| Magnehelic (large dial) type filter pressure monitor gauge |
| Sound Level |
| Insulated so sound does not exceed 85 decibels at 5 feet |
| Electrical Connections |
| Must be 18 inches from floor |
| Shipping |
| F.O.B. Destination – All parts damaged in shipping shall be replaced at no cost |
| Warranty |
| Minimum of 3 year factory warranty on all parts preferred |
| Safety |
| Regulatory compliant including OSHA/NFPA joint “National Combustible Dust Emphasis Program” initiatives |