HQ051678556-16SPB-2515-06_Lights_&_Curtains_&_TRNG_(SC).doc
DOC document 51 KB Posted
- Attached to
- AFN Lights, Curtains & Training
- Solicitation number
- HQ0516-17-R-0052
- Issued by
-
Defense Media Activity
About this file
Salient Characteristics - AFN Lights, Curtains & Training
View the file
Other files
| File | Type | Posted |
|---|---|---|
| HQ0516-17-R-0052_AFN_Lights,_Curtains_&_Training_Solicitation.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
16SPB-2515-06 AFN Okinawa - TV Studio – Lights & Curtains Salient Characteristics
CLIN 001
Lowel PRM-200DA (or equivalent)
1) 5,600 daylight balanced
2) Color rendering index of 91+
3) 90-250 VAC
4) Manual and DMX dimming
5) Photometrics:
a. 303 fc @ 3.0'
b. 84 fc @ 6.0'
c. 39 fc @ 9.0'
d. 22 fc @ 12'
e. 16 fc @ 15'
6) Quiet operation
7) Hanging clamp and stand mount configurations
Requirement: 3 EA
CLIN 002
Lowel PRM-400DA (or equivalent)
1) 5,600 daylight balance
2) Color rendering index of 91+
3) 90-250 VAC
4) Manual and DMX dimming
5) Photometrics:
a. 562 fc @ 3.0' (0.9 m)
b. 156 fc @ 6.0' (1.8 m)
c. 73 fc @ 9.0' (2.7 m)
d. 43 fc @ 12' (3.7 m)
e. 29 fc @ 15' (4.6 m)
6) Quiet operation
7) 50 degree beam angle
8) Hanging clamp and stand mount configurations
Requirement: 18 EA
CLIN 003
Lowel PRM-220: Prime Barndoor Softening Set (or equivalent)
1) Fits CLIN 001
2) Controls Spill
3) Narrows beam angle
4) Minimizes multi-shadow
5) Aluminum construction
Requirement: 21 EA
CLIN 004
Lowel DMX-025: 25 ft DMX Cable (or equivalent)
1) 25’ cable with male and female DMX connectors Requirement: 21 EA
CLIN 005
Lowel DMX-TM: DMX Terminator - For connecting console to one or more fixtures, daisy-chain style, for remote DMX dimming. (or equivalent)
1) DMX Terminator - For connecting console to one or more fixtures, daisy-chain style, for remote DMX dimming Requirement: 2 EA
CLIN 006
Matthews B429728: Lightweight Telescoping Hanger with Clamp - 4 - 8' (or equivalent)
1) 4 to 8 feet Telescoping Hanger with Pipe Clamp
2) Designed for use with light weight fluorescent or other fixtures weighing no more than 25 lbs
3) Aluminum with internally welded safety collars and cast aluminum fittings Requirement: 10 EA
CLIN 007
Matthews B429720: Lightweight Telescoping Hanger with Clamp - 1 - 2' (or equivalent)
1) 1 to 2 foot Telescoping Hanger with Pipe Clamp
2) Designed for use with light weight fluorescent or other fixtures weighing no more than 25 lbs
3) Aluminum with internally welded safety collars and cast aluminum fittings Requirement: 11 EA
CLIN 008
Rose Brand BLACK: Black 128" Poly Cyc Curtain IFR (Sold Per Yard) Medium weight Avora™ polyester (or equivalent)
1) Black in color
2) Medium weight
3) 128” Wide
4) 100% Avora blend polyester material
Requirement: 18 YD
CLIN 009
Rose Brand Cranberry: Dark Red 128" Poly Cyc Curtain IFR (Sold Per Yard) Medium weight Avora™ polyester (or equivalent)
1) Dark Red in color
2) Medium weight
3) 128” Wide
4) 100% Avora blend polyester material
Requirement: 18 YD
CLIN 010
Rose Brand Navy: Navy 128" Poly Cyc Curtain IFR (Sold Per Yard) Medium weight Avora™ polyester (or equivalent)
1) Navy Blue in color
2) Medium weight
3) 128” Wide
4) 100% Avora blend polyester material
Requirement: 18 YD
CLIN 011
Rose Brand Chroma Key Blue: C.K. Blue 128" Poly Cyc Curtain IFR (Sold Per Yard) Medium weight Avora™ polyester (or equivalent)
1) Chroma Key Blue in color
2) Medium weight
3) 128” Wide
4) 100% Avora blend polyester material
Requirement: 18 YD
CLIN 012
Rose Brand Chroma Key Green: C.K. Green128" Poly Cyc Curtain IFR (Sold Per Yard) Medium weight Avora™ polyester (or equivalent)
1) Chroma Key Green in color
2) Medium weight
3) 128” Wide
4) 100% Avora blend polyester material Requirement: 18 YD
CLIN 013
S&K Theatrical Draperies 1300 Curtain Track: FLEX-I-TRACK Curtain track I-Beam type curtain track channel (per foot) (or equivalent)
1) 13 guage extruded aluminum, mill finish
2) 5/8”x1-11/16” (WxH)
Requirement: 100 FT
CLIN 014
S&K Theatrical Draperies 1308 Hanging Clamp: Hanging Clamp (or equivalent)
1) Used to hang CLIN 013
2) ¾”x3/4”x1-3/4” (WxLxH)
3) Adjustable to any location
Requirement: 30 EA
CLIN 015
S&K Theatrical Draperies 1713 Pipe Clamp: Pipe Clamp (or equivalent)
1) 1” diameter
2) Schedule 40 pipe
3) Black finish
Requirement: 30 EA
CLIN 016
S&K Theatrical Draperies 1337 Single Carrier: Nylon Ball-Bearing Single Carrier (or equivalent)
1) 12” Carrier spacing
2) 1/1/8” wide
3) Plated swivel for free, effortless curtain movement
4) Must provide “bumper to bumper” action
Requirement: 60 EA
CLIN 017
S&K Theatrical Draperies 1309 End Stop: End Stop - Prevents carriers from moving beyond selected position (or equivalent)
1) Compatible with CLIN 013 Requirement: 2 EA
CLIN 018
S&K Theatrical Draperies 1324 Splicing Clamp: Splicing Clamp - plate for joining track sections assuring proper alignment (or equivalent)
1) 4”x5/16”x5/16” (LxWxH)
2) Able to join to two sections of CLIN 013
Requirement: 6 EA
CLIN 019
S&K Theatrical Draperies BT2 Bending Tool: Track Bending Tool - I-beam track bending tool (or equivalent)
1) Able to bend CLIN 013 Requirement: 1 EA
CLIN 020
ETC SF1248: SmartFade 1248, 48 Channel DMX Control Console - 12/48 Controller Console - Single or Two Scen Operations - Smart Fade (or equivalent)
1) Preset or memory style operation
2) 12 channel two-scene mode with timed fades
3) 48 channel Normal mode with 288 Memories
4) Fully programmable 199 step cue stack
5) 24 step sequences
6) Tap tempo mode for sequence timing
7) Magic function for random output
8) Undo function
9) 10 Snapshot memories for temporary storage
10) Solo or pile-on mode for bump buttons
11) LCD display for configuration and preview
12) Multiple consoles can be linked via MIDI to increase channel count
13) DMX512 Output
14) DMX512 Input
15) MIDI In
16) MIDI out
Requirement: 1 EA
CLIN 021
ETC 9910-6AO / 1-R-18: Power Distribution Strips (or equivalent)
1) 10 ft long
2) 6 U-Ground Outlets
3) 20 Amps
4) 1 Circuit
5) Right terminal location
6) With Type 18, 90 degree pipe mount bracket
Requirement: 5 EA
CLIN 022
ETC Smartfade console, lighting fixtures, and general studio lighting training (4 days)
1) Training on the setup, configuration, operation, and maintenance of the ETC Smartfade console
2) Training on installation, setup, and configuration of the lighting fixtures
3) Training covering general studio lighting techniques and best practices
4) 4 days onsite at the AFN Okinawa facility for eight to sixteen personnel
Requirement: 1 EA
CLIN 023
Training Travel, Lodging, Meals, and Incidentals
1) Air Travel to Okinawa, Japan
2) Excess Bag
3) Rental Car in Okinawa, Japan
4) Lodging, Meals, and Incidentals (Joint Travel Regulations Per Diem)
Requirement 1 EA
File details come from the government source that posted it. Updated .