The file's text, extracted by GovTribe without its formatting.
Statement of Work (SOW) for Human Machine Interface (HMI) Equipment
1.0 INTRODUCTION
1.0.1 The Naval Surface Warfare Center Philadelphia Division (NSWCPD) is a Department of Defense entity responsible for research and development, test and evaluation, engineering and fleet support organization for the Navy’s ships, submarines, military watercraft and unmanned vehicles. This requirement is for NSWCPD Code 516, which is responsible for machinery controls engineering support and advanced damage control systems support.
1.1 BACKGROUND
The requirement is in support of a contract for Propulsion Auxiliary Control, Damage Control, Ballast Control, and various machinery control Human-Machined Interfaces (HMI). These HMIs shall be used on U.S. Naval Ships, Military Sealift Command, Army, U.S. Coast Guard and foreign Navy Ships to control and monitor multiple systems. The requirement includes processors, Central Processing Unit (CPU) enclosures, flat panel displays, deck mounted consoles, bulkhead mounted consoles, associated hardware and peripheral equipment used to display and control system specific information.
1.2 SCOPE OF WORK
Please see section 3.0 for a full listing of required equipment
2.0 APPLICABLE DOCUMENTS
Not applicable
3.0 REQUIREMENTS
3.1 Contractor shall provide the following:
| Item # |
| Item Name |
| Year 1 |
| Year 2 |
| Year 3 |
| Year 4 |
| Year 5 |
| 1 |
| 24" Operator Interface Panel (OIP) w/ Item 8 Sealed CPU and w/bracket |
| 50 |
| 50 |
| 50 |
| 50 |
| 50 |
| 2 |
| Connector Kit for Item 0001 |
| 100 |
| 100 |
| 100 |
| 100 |
| 100 |
| 3 |
| 24" Flat Panel Display (FPD) (for single & dual monitor consoles) |
| 110 |
| 110 |
| 110 |
| 110 |
| 110 |
| 4 |
| 42" Flat Panel Display (FPD) w/bracket |
| 25 |
| 25 |
| 25 |
| 25 |
| 25 |
| 5 |
| Connector Kit for Item 4 |
| 50 |
| 50 |
| 50 |
| 50 |
| 50 |
| 6 |
| 46" Flat Panel Display (FPD) w/bracket |
| 25 |
| 25 |
| 25 |
| 25 |
| 25 |
| 7 |
| Connector Kit for Item 6 |
| 50 |
| 50 |
| 50 |
| 50 |
| 50 |
| 8 |
| Sealed CPU |
| 225 |
| 225 |
| 225 |
| 225 |
| 225 |
| 9 |
| Power Adapter for Item 8 |
| 225 |
| 225 |
| 225 |
| 225 |
| 225 |
| 10 |
| Sit Down Dual Monitor Console (SDDM) |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 11 |
| Connector Kit for Item 10 |
| 20 |
| 20 |
| 20 |
| 20 |
| 20 |
| 12 |
| Stand Up Dual Monitor Console (SUDM) |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 13 |
| Connector Kit for Item 12 |
| 20 |
| 20 |
| 20 |
| 20 |
| 20 |
| 14 |
| Sit Down Single Monitor Console (SDSM) |
| 35 |
| 35 |
| 35 |
| 35 |
| 35 |
| 15 |
| Connector Kit for Item 14 |
| 70 |
| 70 |
| 70 |
| 70 |
| 70 |
| 16 |
| Stand Up Single Monitor Console (SUSM) |
| 10 |
| 10 |
| 10 |
| 10 |
| 10 |
| 17 |
| Connector Kit for Item 16 |
| 20 |
| 20 |
| 20 |
| 20 |
| 20 |
| 18 |
| Operator Interface Computer (OIC) CPU Enclosure 1 w/bracket |
| 50 |
| 50 |
| 50 |
| 50 |
| 50 |
| 19 |
| Connector Kit for Item 18 |
| 100 |
| 100 |
| 100 |
| 100 |
| 100 |
| 20 |
| Operator Interface Computer (OIC) CPU Enclosure 2 w/bracket |
| 50 |
| 50 |
| 50 |
| 50 |
| 50 |
| 21 |
| Connector Kit for Item 20 |
| 100 |
| 100 |
| 100 |
| 100 |
| 100 |
| 22 |
| Rugged Keyboard/trackball/mounting bracket |
| 50 |
| 50 |
| 50 |
| 50 |
| 50 |
| 23 |
| Rack Mounted Uninterruptable Power Supply (UPS) |
| 5 |
| 5 |
| 5 |
| 5 |
| 5 |
| 24 |
| Tower-Style Uninterruptable Power Supply (UPS) 1.5KVA |
| 20 |
| 20 |
| 20 |
| 20 |
| 20 |
| 25 |
| UPS Foundation |
| 20 |
| 20 |
| 20 |
| 20 |
| 20 |
| 26 |
| UPS Connector Kit - Input |
| 50 |
| 50 |
| 50 |
| 50 |
| 50 |
| 27 |
| UPS Connector Kit - Output |
| 100 |
| 100 |
| 100 |
| 100 |
| 100 |
| 28 |
| Mod kit for console RGB video connection |
| 20 |
| 20 |
| 20 |
| 20 |
| 20 |
3.2 Environmental Qualification Testing (EQT)
All equipment shall meet or exceed the following EQT standards:
Equipment Environmental Requirements
| Shock |
| MIL-S-901D Grade A, Class 1, Type A – Deck and Hull Mounting |
| Vibration |
| MIL-STD-167-1A, Type 1 |
| EMI |
| MIL-STD-461G (surface ship, below deck) |
| EMI (Rugged Keyboard) |
| MIL-STD-461F (surface ship, below deck) |
| High Operating Temperature |
| MIL-STD-810G Method 501.6, Procedure II |
(Test to maximum days suggested in MIL-STD for max temperature and max load)
| High Storage Temperature |
| MIL-STD-810G Method 501.6, Procedure I |
| Low Operating Temperature |
| MIL-STD-810G Method 502.6, Procedure II |
| Low Storage Temperature |
| MIL-STD-810G Method 502.6, Procedure I |
| Humidity |
| MIL-STD-810G, Method 507.6 (0-95% non-condensing) |
| Power |
| MIL-STD-1399 SECTION 300B |
| Grounding and Bonding |
| MIL-STD-1310G |
| Human Factors |
| MIL-STD-1472G |
3.3 Equipment Technical Specifications
All equipment shall meet or exceed the following technical specifications:
24” Operator Interface Panel (OIP) w/ Sealed CPU and Mounting Bracket
| General |
| Touchscreen shall function properly with a Flash Fire Glove. |
General
Shall include Section 3.1 item 8 removable Sealed CPU.
| General |
| Shall include bulkhead mounting bracket and bracket to equipment mounting hardware. |
| Enclosure |
| Dust and water resistance shall be IP65 (Reference IEC 60529). |
| Door |
| Shall consist of a complete integral unit with a hinged bezel for maintenance efforts. |
| Door |
| Bezel shall be able to be physically secured using a hasp with lock. |
| Cooling |
| Shall have passive cooling (no moving parts). |
| Physical Security |
| Shall be lockable. |
| Display Type |
| Liquid Crystal Display (LCD) |
| Backlight |
| Light Emitting Diode (LED) backlight |
| Pointer |
| Shall contain a bezel mounted pointer with right & left click. |
| Touch Screen |
| single touch resistive 5+ wire |
| Glass |
| 2.8mm Tempered Glass |
| Min Viewing Angle |
| 85° Horizontal & Vertical |
| Brightness Control |
| 0-100% |
| Material |
| 0.125” Aluminum 5052-H32 Alloy. Chemically treated IAW MIL-DTL 5541, Type II, Class 1A. Material shall not contain hexavalent chromium. |
| Weight |
| Not to Exceed (NTE) 60lbs with mount bracket. |
| Max Power Consumption |
| NTE 100W |
| Dimensions |
| NTE 26.0” (W) x 18” (H) x 12.0” (D) (with mounting) |
| Mounting Bracket |
| Tilt Angle: 15 ° Up/Down: Material: .187” Aluminum Plate |
| USB |
| Two (2) USB 3.0 external I/O ports |
| External I/O Ports |
| All external connections shall have a positive locking mechanism with mating metal dust cap and tether. |
| Fiber |
| Fiber Ethernet: Support for a minimum of two (2) 1000BaseLX, 100BaseFX, or 1000BaseSX native fiber NICs (no media converters). Two (2) external cable glands |
| Copper Ethernet |
| Three (3) 10/100/1000BaseTX external RJ45 I/O ports |
| Isolated GPIO/DIO: |
| Support for a minimum of four (4) DI and four (4) DO. |
One (1) DIO/GPIO external I/O port
Rating: 2x max power consumption
Connector: MS27656T15B5P
Current 2.7A max @ 115VAC
On/Off Switch: Toggle Switch STDP, 15A, Water Tight
Fusing: 2 internal fuses (5A); delta/wye power
Minimum volume control shall not be less than10dB
24” OIP Connector Kit
| General |
| Connector kit shall consist of mating connectors and/or cables for all OIP external I/O. |
Power
1pc D38999/26WC4SN, Mil-Power Mating Connector
| Fiber Ethernet |
| Shall have two (2) stuffing tubes provided for fiber connections. Field fiber cables shall penetrate the OIP and land to an included internal ST-ST patch panel which provides the mating junction to the fiber ports on the CPU. Fiber jumpers from CPU fiber ports to ST-ST patch panel shall come pre-installed – two Single-mode & two Multimode to account for all flavors of fiber Ethernet. |
| Copper Ethernet |
| Mil Spec Connector Support for a minimum of three (3) 10/100/1000BaseTX native copper network interfaces |
3 pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors
| Isolated GPIO/DIO |
| Support for a minimum of four (4) DI and four (4) DO Cap: mating metal cap for all OIP box mounted connectors |
1pc D38999/26WC35SN, DIO/GPIO Mating Connector
| USB |
| 3pc USB3FTV5G Circular Mil-USB 3.0 Mating Connector |
24” Flat Panel Display (for single & dual monitor consoles)
| General |
| Touch screen shall function properly with a Flash Fire Glove. |
| General |
| Shall be integrated into single and dual monitor consoles. |
| General |
| Not separately tested. To be tested as part of full assemblies. |
| Enclosure |
| Dust and water resistance shall be IP65 (REFERENCE IEC 60529) when mounted. |
| Cooling |
| Shall have passive cooling (no moving parts). |
| Touchscreen |
| Single touch resistive 5 wire |
| Brightness Control |
| 0-100% |
| Glass |
| 2.8mm Tempered Glass |
| Min Viewing Angle |
| 85° Horizontal & Vertical |
| I/O Ports |
| Standard A-B USB 2.0 for touch interface |
| Video Inputs |
| (1) VGA, (1) HDMI, or (1) Display Port |
42” Flat Panel Display (FPD) and Mounting Bracket
| General |
| Touch screen shall function properly with a Flash Fire Glove. |
| General |
| Shall operate and interface with Section 3.1 item 18 Operator Interface Computer (OIC) CPU Enclosure 1, Section 3.1 item 20 OIC CPU Enclosure 2, and Section 3.1 item 8 Sealed CPU. |
| General |
| Shall include bulkhead mounting bracket and bracket to equipment mounting hardware. |
| Enclosure |
| Dust and water resistance shall be IP65 (REFERENCE IEC 60529). |
| Cooling |
| Shall have Passive cooling (no moving parts). |
| Touchscreen |
| IR multi-touch |
| Resolution |
| Native 1920X1080 |
| Brightness Control |
| 0-100% |
| Glass |
| 2.8mm Tempered Glass |
| Min Viewing Angle |
| 85° Horizontal & Vertical |
| External I/O Ports |
| Standard A USB 2.0 for touch interface |
| External I/O Ports |
| All external connections shall have a positive locking mechanism with mating metal dust cap and tether. |
| External Video Inputs |
| (1) HDMI (shall be able to transfer Audio through same cable) |
| Power |
| 85-264VAC (Power On/Off Switch) |
| Integrated Speaker w/ Volume Control |
| 110db at 2 feet orthogonal to display (Sound will pass through HDMI) |
| Weight |
| NTE 105lbs (with mounting brackets) |
| Power Consumption |
| NTE 105W |
| Dimensions |
| NTE 45.0 (W) x 29.0 (H) x 7.0 (D) (With Vertical Mounting Bracket) |
NTE 45.0 (W) x 29.0 (H) x 15.0 (D) (With 15 ° angled bracket).
| Mounting Bracket |
| Tilt Angle: 15 ° Up/Down |
Material: .187” Aluminum Plate, 42” Flat Panel Display Connector (FPD) Kit
| General |
| Connector kit shall consist of mating connectors, back shells, and/or cables for all FPD external I/O. |
Power
1pc D38999/26WC4SN, Mil-Power Mating Connector
| HDMI Cable |
| 1pc HD-WTP-WMWM-5M, Mating Cable Assembly |
| USB Cable |
| 1pc USB A-A Black 5 Meters |
| USB |
| 2pc USBFTV6G, Mating Connector |
46” Flat Panel Display (FPD) and Mounting Bracket
| General |
| Touch screen shall work with a Flash Fire Glove. |
| General |
| Shall operate and interface with Section 3.1 item 18 Operator Interface Computer (OIC) CPU Enclosure 1, Section 3.1 item 20 OIC CPU Enclosure 2, and Section 3.1 item 8 Sealed CPU. |
| General |
| Shall include bulkhead mounting bracket and bracket to equipment mounting hardware. |
| Enclosure |
| Dust and water resistance shall be IP65 (REFERENCE IEC 60529). |
| Cooling |
| Shall have Passive cooling (no moving parts). |
| Touchscreen |
| IR multi-touch |
| Resolution |
| native 1920X1080 |
| Brightness Control |
| 0-100% |
| Glass |
| 2.8mm Tempered Glass |
| Min Viewing Angle |
| 85° Horizontal &Vertical |
| External I/O Ports |
| Standard A USB 2.0 for touch interface |
| External I/O Ports |
| All external connections shall have a positive locking mechanism with mating metal dust cap and tether. |
| External Video Inputs |
| (1) HDMI (shall be able to transfer Audio through same cable) |
| Power |
| 85-264VAC (Power On/Off Switch) |
| Integrated Speaker w/ Volume Control |
| 90db at 2 feet orthogonal to display (Sound will pass through HDMI) |
| Weight |
| NTE 122lbs (With Mounting Bracket) |
| Power Consumption |
| NTE 105 W |
| Dimensions |
| 50.0 (W) x 30.0 (H) x 8.0 (D) (With Vertical Mounting Bracket) |
50.0 (W) x 30.0 (H) x 17.0 (D) (With 15 ° angled bracket)
| Mounting Bracket |
| Tilt Angle: 15 ° Up/Down |
Material: .187” Aluminum Plate, 46” Flat Panel Display (FPD) Connector Kit
| General |
| Connector kit shall consist of mating connectors, back shells, and/or cables for all FPD external I/O. |
Power
1pc D38999/26WC4SN, Mil-Power Mating Connector
| HDMI Cable |
| 1pc HD-WTP-WMWM-5M, Mating Cable Assembly |
| USB Cable |
| 1pc USB A-A Black 5 Meters |
| USB |
| 2pc USBFTV6G, Mating Connector |
Sealed CPU (Latest Generation)
| Enclosure |
| Dust and water resistance shall be IP54. |
| Cooling |
| Shall be fan-less, passively cooled, completely solid state without a display, and no moving parts. |
| General |
| Shall be fan-less, passively cooled, completely solid state without a display. |
| Supportability |
| Hardware shall be in line with Intel’s long term embedded computing roadmap. |
| Dimensions |
| 11.0”(W) x 4.0”(H) x 7.0”(D) |
| USB |
| USB: minimum of four (4) USB 3.0 and two (2) USB 2.0 ports |
| Fiber |
| Fiber Ethernet: Support for a minimum of two (2) 1000BaseLX, 100BaseFX, or 1000BaseSX native fiber NICs (no media converters) |
| Copper Ethernet |
| Copper Ethernet: Support for a minimum of three (3) 10/100/1000BaseTX |
| Isolated DIO |
| Isolated GPIO/DIO: Support for a minimum of four (4) DI and four (4) DO |
| Power |
| Input Power: 12V-36 VDC |
| Power Connector |
| 2-pin Terminal Block: V+, V- |
| CPU |
| Minimum processor performance requirements shall be Intel® Core Processor i7 3.4 GHz or Greater |
| Memory |
| 16GB RAM (single DIMM low power) expandable to 32GB RAM (single DIMM low power) |
| Video |
| Integrated AGP Controller |
| Video Output |
| Video Output: Minimum (1) VGA and (1) HDMI or (1) Display port |
| BIOS |
| Must allow administrator lockout of USB ports |
Must allow administrator password access.
| CFast |
| Cfast: 64 GB Wide-Temp Cfast card, User-Accessible |
| Storage |
| Two (2) Solid State Drives with power fail write protection in RAID 1 |
SSD Drive Capacity (each):
256GB EA SSD Type: Intel Wide-Temp SSD or equivalent
| OS |
| Computers shall be compatible with all of the following: Windows 7 Embedded, |
Windows 10 IOT, Windows 11, RHL 7.x and newer
Power Adapter for Sealed CPU
| General |
| Power Adapter shall be a standard power adapter to allow for lab testing. Shall be 120VAC Input, 24VDC Output with standard 120VAC plug on input end and matingplug-in power terminal block on output end. |
Sit Down Dual Monitor (SDDM) Console
| General |
| Touch screen shall function properly with flash fire glove. |
| Console |
| Dust and Water resistance shall be IP65 (REFERENCE IEC 60529). |
| Cooling |
| Shall be passive no moving Parts (fanless). |
| Keyboard |
| Shall have full function USB (114 keys). |
| Trackball |
| Shall have built-in rugged trackball NEMA compliant. |
| Monitors |
| Two (2) integrated Flat Panel Displays |
| Lower Monitor Viewing Angle |
| Lower monitor shall mount at a 105-degree viewing angle. |
| Upper Monitor Viewing Angle |
| Upper monitor shall mount at a 65-degree viewing angle. |
| Computer |
| Shall be compatible with integrating Section 3.1 item 8 Sealed CPU into consoles’ lower bay. |
| Mounting |
| The console shall employ a “hard mount” configuration without the use of shock isolation mounts. |
| Color |
| FED-STD-595B, No. 26307 light equipment gray. |
| Access & Security |
| The console configuration shall provide front access for normal maintenance of the enclosed components and peripherals. Locking capability using a hasp is required. |
| Cable Penetrations |
| Bulkhead-type, sealed cable penetrations (Roxtec) shall be used for external cabling. All penetrations shall be made at the side and rear vertical panel no more than 6” from the bottom base and shall not preclude compliance with the referenced environmental requirements. |
| I/O Panel |
| Inner I/O panel with positive locking MIL-STD connections for two (2) 10/100/1000BaseTX external RJ45 I/O ports and one (1) primary power port |
| ID Nameplate |
| An ID nameplate label shall be secured to the inside console access door. In accordance with MIL-DTL-15024F Type E, MIL-M-43719 Type I adhesive backed film adhered to aluminum alloy sheet. Lettering shall be screen or litho print |
| PDU |
| A power distribution unit (PDU) shall be installed. Shall have Power receptacles inside base to allow hook up for computers and monitors |
| Voltage |
| Voltage: 85-264VAC |
| Input Power |
| 90 to 132 VAC Single Phase. (Power On/Off Switch). |
| Line Frequency |
| Nominal 60Hz |
| Power Consumption |
| NTE 150 W |
| Integrated Speaker |
| 110 db output with volume control |
| Max Height |
| 69.0” (Not including foundation) |
| Foundation |
| Hard mounted. Shall mount to existing foundation bolt hole pattern. |
SDDM Connector Kit
| General |
| Connector kit shall consist of mating connectors and/or cables for all SDDM external I/O. |
Power
1pc D38999/26WC4SN, Mil-Power Mating Connector
| Ethernet |
| 2pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors. |
| Clamp |
| 1pc M85049/38-13W Cable Clamp. |
Stand Up Dual Monitor (SUDM) Console
| General |
| Touch screen shall function properly with flash fire glove. |
| Console |
| Dust and Water Resistance shall be IP65 (REFERENCE IEC 60529). |
| Cooling |
| Shall be passive no moving Parts (fanless). |
| Keyboard |
| Shall have full function USB (114 keys). |
| Trackball |
| Shall have built-in rugged trackball NEMA compliant. |
| Monitors |
| Two (2) integrated 24” Flat Panel Displays. |
| Lower Monitor Viewing Angle |
| Lower monitor shall mount at a 75-degree viewing angle |
| Upper Monitor Viewing Angle |
| Upper monitor shall mount at a 90-degree viewing angle |
| Computer |
| Shall be compatible with integrating Section 3.1 item 8 Sealed CPU into consoles’ lower bay. |
| Mounting |
| The console shall employ a “hard mount” configuration without the use of shock isolation mounts |
| Color |
| FED-STD-595B, No. 26307 light equipment gray. |
| Access & Security |
| The console configuration shall provide front access for normal maintenance of the enclosed components and peripherals. Locking capability using a hasp is required. |
| Cable Penetrations |
| Bulkhead-type, sealed cable penetrations (Roxtec) shall be used for external cabling. All penetrations shall be made at the side and rear vertical panel no more than 6” from the bottom base and shall not preclude compliance with the referenced environmental requirements. |
| I/O Panel |
| Inner I/O panel with positive locking MIL-STD connections for two (2) 10/100/1000BaseTX external RJ45 I/O ports and one (1) primary power port |
| ID Nameplate |
| An ID nameplate label shall be secured to the inside console access door. In accordance with MIL-DTL-15024F Type E, MIL-M-43719 Type I adhesive backed film adhered to aluminum alloy sheet. Lettering shall be screen or litho print |
| PDU |
| A power distribution unit (PDU) shall be installed. Shall have Power receptacles inside base to allow hook up for computers and monitors |
| Voltage |
| Voltage: 85-264VAC (power on/off switch) |
| Input Power |
| 90 to 132 VAC Single Phase |
| Line Frequency |
| Nominal 60Hz |
| Power Consumption |
| NTE 150 W |
| Integrated Speaker |
| 110 db output with volume control |
| Max Height |
| 80.0. (Not including foundation) |
| Foundation |
| Hard mounted. Shall mount to existing foundation bolt hole pattern. |
SUDM Connector Kit
| General |
| Connector kit shall consist of mating connectors and/or cables for all SUDM external I/O. |
Power
1pc D38999/26WC4SN, Mil-Power Mating Connector
| Ethernet |
| 2pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors. |
| Clamp |
| 1pc M85049/38-13W Cable Clamp. |
Sit Down Single Monitor (SDSM) Console
| General |
| Touch screen shall function properly with flash fire glove. |
| Console |
| Dust and Water resistance shall be IP65 (REFERENCE IEC 60529). |
| Cooling |
| Shall be passive no moving Parts (fanless). |
| Keyboard |
| Shall have full function USB (114 keys). |
| Trackball |
| Shall have built-in rugged trackball NEMA compliant. |
| Monitor |
| One (1) integrated 24” Flat Panel Display |
| Monitor Viewing Angle |
| Monitor shall mount at a 105-degree viewing angle |
| Computer |
| Shall be compatible with integrating Section 3.1 item 8 Sealed CPU into consoles’ lower bay. |
| Mounting |
| The console shall employ a “hard mount” configuration without the use of shock isolation mounts. |
| Color |
| FED-STD-595B, No. 26307 light equipment gray. |
| Access & Security |
| The console configuration shall provide front access for normal maintenance of the enclosed components and peripherals. Locking capability using a hasp is required. |
| Cable Penetrations |
| Bulkhead-type, sealed cable penetrations (Roxtec) shall be used for external cabling. All penetrations shall be made at the side and rear vertical panel no more than 6” from the bottom base and shall not preclude compliance with the referenced |
environmental requirements.
| I/O Panel |
| Inner I/O panel with positive locking MIL-STD connections for two (2) 10/100/1000BaseTX external RJ45 I/O ports and one (1) primary power port |
| ID Nameplate |
| An ID nameplate label shall be secured to the inside console access door. In accordance with MIL-DTL-15024F Type E, MIL-M-43719 Type I adhesive backed film adhered to aluminum alloy sheet. Lettering shall be screen or litho print |
| PDU |
| A power distribution unit (PDU) shall be installed. Shall have Power receptacles inside base to allow hook up for computers and monitors |
| Voltage |
| Voltage: 85-264VAC |
| Input Power |
| 90 to 132 VAC Single Phase (power on/off switch) |
| Line Frequency |
| Nominal 60Hz |
| Power Consumption |
| NTE 120 W |
| Max Height |
| 54.0” (Not including foundation) |
| Foundation |
| Hard mounted. Shall mount to existing foundation bolt hole pattern. |
SDSM Connector Kit
| General |
| Connector kit shall consist of mating connectors and/or cables for all SDSM external I/O. |
Power
1pc D38999/26WC4SN, Mil-Power Mating Connector
| Ethernet |
| 2pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors. |
| Clamp |
| 1pc M85049/38-13W Cable Clamp. |
SUSM Console
| General |
| Touch screen shall function properly with flash fire glove. |
| Console |
| Dust and Water resistance shall be IP65 (REFERENCE IEC 60529). |
| Cooling |
| Shave be passive no moving Parts (fanless). |
| Keyboard |
| Shall have full function USB (114 keys). |
| Trackball |
| Shall have built-in rugged trackball NEMA compliant. |
| Monitor |
| One (1) integrated 24” Flat Panel Display console |
| Monitor Viewing Angle |
| Monitor shall mount at a 75-degree viewing angle |
| Computer |
| Shall be compatible with integrating Section 3.1 item 8 Sealed CPU into consoles’ lower bay. |
| Mounting |
| The console shall employ a “hard mount” configuration without the use of shock isolation mounts |
| Color |
| FED-STD-595B, No. 26307 light equipment gray. |
| Access & Security |
| The console configuration shall provide front access for normal maintenance of the enclosed components and peripherals. Locking capability using a hasp is required. |
| Cable Penetrations |
| Bulkhead-type, sealed cable penetrations (Roxtec) shall be used for external cabling. All penetrations shall be made at the side and rear vertical panel no more than 6” from the bottom base and shall not preclude compliance with the referenced environmental requirements. |
| I/O Panel |
| Inner I/O panel with positive locking MIL-STD connections for two (2) 10/100/1000BaseTX external RJ45 I/O ports and one (1) primary power port |
| ID Nameplate |
| An ID nameplate label shall be secured to the inside console access door. In accordance with MIL-DTL-15024F Type E, MIL-M-43719 Type I adhesive backed film adhered to aluminum alloy sheet. Lettering shall be screen or litho print |
| PDU |
| A power distribution unit (PDU) shall be installed. Shall have Power receptacles inside base to allow hook up for computers and monitors |
| Voltage |
| Voltage: 85-264VAC |
| Input Power |
| 90 to 132 VAC Single Phase (power on/off switch) |
| Line Frequency |
| Nominal 60Hz |
| Power Consumption |
| NTE 120 W |
| Max Height |
| 63” (Not including foundation) |
| Foundation |
| Hard mounted. Shall mount to existing foundation bolt hole pattern. |
SUSM Connector Kit
| General |
| Connector kit shall consist of mating connectors and/or cables for all SUSM external I/O. |
Power
1pc D38999/26WC4SN, Mil-Power Mating Connector
| Ethernet |
| 2pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors. |
| Clamp |
| 1pc M85049/38-13W Cable Clamp. |
Operator Interface Computer (OIC) CPU Enclosure Configuration 1 and Mounting Bracket
| General |
| The enclosure shall be fanless, passively cooled, and without a display. |
| General |
| The enclosure shall house and mount Section 3.1 item 8 removable Sealed CPU with respective connector kits. |
| General |
| Shall integrate with 46” and 42” Flat Panel Displays providing video, audio and touch receiving touch screen inputs with all required Operating Systems. |
| General |
| Shall include bulkhead mounting bracket and bracket to equipment mounting hardware. |
| Enclosure |
| Dust and Water Resistance shall be IP65 (REFERENCE IEC 60529). |
| Physical Security |
| Shall be lockable with a hasp |
Rating: 2x max power consumption
Connector: MS27656T15B5P
Current 2.7A max @ 115VAC
On/Off Switch: Toggle Switch STDP, 15A, Water Tight
CPU ON/OFF Switch
Fusing: 2 internal fuses (5A); delta/wye power
| Foundation |
| Shall be hard mounted. |
| External Connection Ports |
| 1 x MIL-STD Power Connector |
2 x Circular MIL-STD RJ45 Ethernet Connectors
2 x Fiber Cable Glands
1 x Circular MIL-STD USB 3.0 Connector 1 x Circular MIL-STD HDMI Output
| External I/O Ports |
| All external connections shall have a positive locking mechanism with mating metal dust cap and tether. |
| Input Power |
| 90 to 132 VAC Single Phase |
| Line Frequency |
| Nominal 60Hz |
| Dimensions |
| 15” (W) x 17” (H) x 11” (D) (With Mounting Bracket) |
Operator Interface Computer (OIC) CPU Enclosure 1 Connector Kit
| General |
| Connector kit shall consist of mating connectors, back shells, and/or cables for all external I/O. |
Power
1pc D38999/26WC4SN, Mil-Power Mating Connector
| Ethernet |
| 2pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors. |
| HDMI Cable |
| 1pc HD-WTP-WMWM-5M HDMI |
Cords Set, IP67 Molded
| USB |
| 1pc USBFTV6G, Mating Connector |
| Clamp |
| 1pc M85049/38-13W Cable Clamp. |
Operator Interface Computer (OIC) CPU Enclosure Configuration 2 and Mounting Bracket
| General |
| The enclosure shall be fanless, passively cooled, and without a display. |
| General |
| The enclosure shall house and mount Section 3.1 item 8 removable Sealed CPU with respective connector kits. |
| General |
| Shall integrate with 46” and 42” Flat Panel Displays providing video, audio and touch receiving touch screen inputs with all required Operating Systems. |
| General |
| Shall include bulkhead mounting bracket and bracket to equipment mounting hardware. |
| Enclosure |
| Dust and Water Resistance shall be IP65 (REFERENCE IEC 60529). |
| Physical Security |
| Shall be lockable with a hasp |
Rating: 2x max power consumption
Connector: MS27656T15B5P
Current 2.7A max @ 115VAC
On/Off Switch: Toggle Switch STDP, 15A, Water Tight
CPU ON/OFF Switch for Soft Shutdown with RED indicator
Fusing: 2 internal fuses (5A); delta/wye power
| Foundation |
| Shall be hard mounted. |
| External Connection Ports |
| 1 x MIL-STD Power Connector |
2 x Circular MIL-STD RJ45 Ethernet Connectors
1 x Circular MIL-STD VGA Video Output
1 x Circular MIL-STD HDMI output
4 x Circular MIL-STD USB 3.0 Connector
2 x Fiber Cable Glands
| External I/O Ports |
| All external connections shall have a positive locking mechanism with mating metal dust cap and tether. |
| Input Power |
| 90 to 132 VAC Single Phase |
| Line Frequency |
| Nominal 60Hz |
| Dimensions |
| 15” (W) x 17” (H) x 11” (D) (With Mounting Bracket) |
Operator Interface Computer (OIC) CPU Enclosure 2 Connector Kit
| General |
| Connector kit shall consist of mating connectors, back shells, and/or cables for all external I/O. |
Power
1pc D38999/26WC4SN, Mil-Power Mating Connector
| Ethernet |
| 2pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors. |
| HDMI Cable |
| 1pc HD-WTP-WMWM-5M HDMI |
Cords Set, IP67 Molded
| USB |
| 4pc USBFTV6G, Mating Connector |
| Clamp |
| 1pc M85049/38-13W Cable Clamp. |
Rugged External Keyboard and Mounting Bracket
| General |
| The keyboard shall have an integrated trackball device and three (3) control buttons. Keyboard shall and 24 function keys. |
| General |
| Shall include bulkhead mounting bracket and bracket to equipment mounting hardware. |
| General |
| Bulk-head Mounted |
| Mounting Bracket |
| Shall include a single bulkhead mounting bracket for both the OIP and Rugged Keyboard. |
| Keyboard |
| The keyboard shall be at a 15 degree angle. |
| Color |
| Equipment Grey FED-STD-595, COLOR NO. 26307 |
| Dimensions |
| 26.0” (W) x 25.0” (H) x 18.0 (D) (With Mounting Bracket) |
| Weight |
| NTE 25lbs (Including Mounting) |
UPS Rack Mounted Requirements
| Enclosure |
| Stainless steel cabinet |
| Mounting |
| Rack 3U Max w/ Rail Kit |
| Power |
| 1.5KVA and 984W Output |
| Outputs/Inputs |
| 2 MIL outputs and 1 MIL input |
| Communication |
| 9640 SNMP card |
| Batteries |
| Premium H batteries |
| Bypass |
| Master Bypass rotary knob |
| Connector shall mate to |
| 2 x Ms3106r16-10p |
1 x Ms3106r16-10s
UPS Mini Tower Requirements
| Enclosure |
| Stainless steel cabinet |
| Mounting |
| Front face hull mount |
| Power |
| 1.5KVA and 984W Output |
| Outputs/Inputs |
| 2 MIL outputs and 1 MIL input |
| Communication |
| 9640 SNMP card |
| Batteries |
| Premium H batteries |
| Bypass |
| Master Bypass rotary knob |
| Foundation |
| Shall be compatible with UPS Mini Tower Foundation Section 3.1 item 25. |
| Connector shall mate to |
| 2 x Ms3106r16-10p |
1 x Ms3106r16-10s
UPS Mini Tower Foundation
| Foundation |
| Bulkhead mounted |
| Foundation |
| Shall be compatible with UPS Mini Tower PS1504 Section 3.1 item 24. |
| General |
| Shall include bulkhead mounting bracket and bracket to equipment mounting hardware. |
UPS Rack Mounted and UPS Mini Tower Input Connector Kit
| General |
| 1 x Ms3106r16-10s |
UPS Rack Mounted and UPS Mini Tower Output Connector Kit
| General |
| 1 x Ms3106r16-10p |
Modification kit for RGB video connection
| General |
| Shall provide a console MOD kit for RGB video to be streamed to outside video. |
| General |
| Shall provide a console MOD kit for a physical external connection for RGB connections. |
4.0 DATA REQUIREMENTS
4.1 The Contractor shall provide the following CDRLs at the required periodicity.
· CDRL A001, Shock Test Procedures
· CDRL A002, Vibration Test Procedures
· CDRL A003, EMI Test Procedures
· CDRL A004, Shock Test Report
· CDRL A005, Vibration Test Report
· CDRL A006, EMI Test Report
· CDRL A007, Power Test Procedures
· CDRL A008, Power Test Report
· CDRL A009, Environmental Engineering Test Procedures
· CDRL A010, Environmental Engineering Test Report
· CDRL A011, As Built Configuration List
· CDRL A012, Equipment Technical Manual
· CDRL A013, Production Drawings/Models and Associated Lists
5.0 SECURITY REQUIREMENTS
5.4 OPERATIONS SECURITY (OPSEC)
5.4.1 The Contractor shall protect critical information associated with this contract to prevent unauthorized disclosure. The NSWC Philadelphia Division's (NSWCPD) Critical Information List (CIL)/ CIIL (Critical Indicators and information list) will be provided on site, if warranted. Performance under this contract requires the contractor to adhere to OPSEC requirements. The Contractor may not impose OPSEC requirements on its subcontractors unless NSWCPD approves the OPSEC requirements. During the period of this contract, the Contractor may be exposed to, use, or produce, NSWCPD Critical Information (CI) and/or observables and indicators which may lead to discovery of CI. NSWCPD’s CI will not be distributed to unauthorized third parties, including foreign governments, or companies under Foreign Ownership, Control, or Influence (FOCI) unless such FOCI has been appropriately mitigated through measures approved by the Defense Counterintelligence and Security Agency. Questions concerning these requirements shall be directed to the PCO.
5.4.2 CUI correspondence transmitted internally on the contractor's unclassified networks or information systems, and externally, shall be protected per NIST SP-800-171, Protecting Controlled Unclassified Information (CUI) in Non-federal Systems and Organizations.
Assembled large components/systems being transported to and from testing areas, other production or government facilities (whether or not on public roadways) shall be in an enclosed van trailer or covered flatbed trailer. Component/System outside storage, staging, and test areas shall be shielded/obscured from public view wherever physically possible.
5.4.3 NSWCPD’s CI shall not be publicized in corporate wide newsletters, trade magazines, displays, intranet pages or public facing websites. Media requests related to this project shall be directed to the PCO, and the COR who will forward the required to the NSWCPD Public Release Authority for review.
5.4.4 Any attempt by unauthorized third parties to solicit, obtain, photograph, or record, or; incidents of loss/compromise of government Classified or CI, Business Sensitive, Company Proprietary information related to this or other program must be immediately reported to the contractor's Facility Security Officer and Cognizant Security Office and/or the Naval Criminal Investigative Service, and the NSWC PD Security Division (Code 105).
5.5 RECEIPT, STORAGE, AND GENERATION OF CONTROLLED UNCLASSIFIED INFORMATION (CUI) All Controlled Unclassified Information (CUI) associated with this contract must follow the minimum marking requirements of DoDI 5200.48, Section 3, paragraph 3.4.a, and include the acronym "CUI" in the banner and footer of the document. In accordance with DoDI 5200.48, CUI must be safeguarded to prevent Unauthorized Disclosure (UD). CUI export controlled technical information or other scientific, technical, and engineering information must be marked with an export control warning as directed in DoDI 5230.24, DoDD 5230.25, and Part 250 of Title 32, CFR. Nonfederal information systems storing and processing CUI shall be protected per NIST SP-800-171, or subsequent revisions. All transmissions to personal email accounts (AOL, Yahoo, Hotmail, Comcast, etc.) and posting on social media websites (Facebook, Instagram, Twitter, LinkedIn, etc.) are prohibited. Destroy CUI associated with this contract by any of the following approved methods: A cross-cut shredder; a certified commercial destruction vendor; a central destruction facility; incineration; chemical decomposition; pulverizing, disintegration; or methods approved for classified destruction.
6.0 PLACE OF PERFORMANCE
Delivery shall be identified at the issuance of the delivery order.
7.0 TRAVEL
Not applicable.
8.0 GOVERNMENT FURNISHED PROPERTY
Not applicable.
9.0 GOVERNMENT FURNISHED INFORMATION
Not applicable.
10.0 PURCHASES
Not applicable.
11.0 Counterfeit Material Prevention
Not applicable.
12.0 PERSONNEL
Not applicable.
13.0 NSWCPD Electronic Cost Reporting and Financial Tracking (eCRAFT) System
Not applicable.
14.0 SPECIAL REQUIREMENTS
Contractor shall provide documentation that verifies all requirements in the Statement of Work are met through operational verification when possible or inspection.
Contractor shall perform interface verification testing between OIC CPU Enclosure 1 and OIC CPU Enclosure 2 with 42” FPD and 46” FPD to ensure all I/O is functioning properly using all required Operating Systems in the Statement of Work. For example all video, audio, and touch screen capabilities shall be verified with each Operating System.
Contractor shall verify each delivered equipment meets the requirements in the Statement of Work and provide documentation to the Government.
15.0 WARRANTY
Contractor shall provide a 12 month warranty from the time of initial shipboard installation and power-up Not to Exceed (NTE) 36 months from receipt of equipment. Receipt inspection of contract items shall not start the official warranty period for procured items.
SOW-PWS Template 30 June 2022 version