Statement of Work (SOW) for Human Machine Interface (HMI) Equipment

1.0 INTRODUCTION

1.0.1 The Naval Surface Warfare Center Philadelphia Division (NSWCPD) is a Department of Defense entity responsible for research and development, test and evaluation, engineering and fleet support organization for the Navy’s ships, submarines, military watercraft and unmanned vehicles. This requirement is for NSWCPD Code 516, which is responsible for machinery controls engineering support and advanced damage control systems support.

1.1 BACKGROUND

The requirement is in support of a contract for Propulsion Auxiliary Control, Damage Control, Ballast Control, and various machinery control Human-Machined Interfaces (HMI). These HMIs shall be used on U.S. Naval Ships, Military Sealift Command, Army, U.S. Coast Guard and foreign Navy Ships to control and monitor multiple systems. The requirement includes processors, Central Processing Unit (CPU) enclosures, flat panel displays, deck mounted consoles, bulkhead mounted consoles, associated hardware and peripheral equipment used to display and control system specific information.

1.2 SCOPE OF WORK

Please see section 3.0 for a full listing of required equipment

2.0 APPLICABLE DOCUMENTS

Not applicable

3.0 REQUIREMENTS

3.1 Contractor shall provide the following:

Item #
Item Name
Year 1
Year 2
Year 3
Year 4
Year 5
1
24" Operator Interface Panel (OIP) w/ Item 8 Sealed CPU and w/bracket
50
50
50
50
50
2
Connector Kit for Item 0001
100
100
100
100
100
3
24" Flat Panel Display (FPD) (for single & dual monitor consoles)
110
110
110
110
110
4
42" Flat Panel Display (FPD) w/bracket
25
25
25
25
25
5
Connector Kit for Item 4
50
50
50
50
50
6
46" Flat Panel Display (FPD) w/bracket
25
25
25
25
25
7
Connector Kit for Item 6
50
50
50
50
50
8
Sealed CPU
225
225
225
225
225
9
Power Adapter for Item 8
225
225
225
225
225
10
Sit Down Dual Monitor Console (SDDM)
10
10
10
10
10
11
Connector Kit for Item 10
20
20
20
20
20
12
Stand Up Dual Monitor Console (SUDM)
10
10
10
10
10
13
Connector Kit for Item 12
20
20
20
20
20
14
Sit Down Single Monitor Console (SDSM)
35
35
35
35
35
15
Connector Kit for Item 14
70
70
70
70
70
16
Stand Up Single Monitor Console (SUSM)
10
10
10
10
10
17
Connector Kit for Item 16
20
20
20
20
20
18
Operator Interface Computer (OIC) CPU Enclosure 1 w/bracket
50
50
50
50
50
19
Connector Kit for Item 18
100
100
100
100
100
20
Operator Interface Computer (OIC) CPU Enclosure 2 w/bracket
50
50
50
50
50
21
Connector Kit for Item 20
100
100
100
100
100
22
Rugged Keyboard/trackball/mounting bracket
50
50
50
50
50
23
Rack Mounted Uninterruptable Power Supply (UPS)
5
5
5
5
5
24
Tower-Style Uninterruptable Power Supply (UPS) 1.5KVA
20
20
20
20
20
25
UPS Foundation
20
20
20
20
20
26
UPS Connector Kit - Input
50
50
50
50
50
27
UPS Connector Kit - Output
100
100
100
100
100
28
Mod kit for console RGB video connection
20
20
20
20
20

3.2 Environmental Qualification Testing (EQT)

All equipment shall meet or exceed the following EQT standards:

Equipment Environmental Requirements

Shock
MIL-S-901D Grade A, Class 1, Type A – Deck and Hull Mounting
Vibration
MIL-STD-167-1A, Type 1
EMI
MIL-STD-461G (surface ship, below deck)
EMI (Rugged Keyboard)
MIL-STD-461F (surface ship, below deck)
High Operating Temperature
MIL-STD-810G Method 501.6, Procedure II

(Test to maximum days suggested in MIL-STD for max temperature and max load)

High Storage Temperature
MIL-STD-810G Method 501.6, Procedure I
Low Operating Temperature
MIL-STD-810G Method 502.6, Procedure II
Low Storage Temperature
MIL-STD-810G Method 502.6, Procedure I
Humidity
MIL-STD-810G, Method 507.6 (0-95% non-condensing)
Power
MIL-STD-1399 SECTION 300B
Grounding and Bonding
MIL-STD-1310G
Human Factors
MIL-STD-1472G

3.3 Equipment Technical Specifications

All equipment shall meet or exceed the following technical specifications:

24” Operator Interface Panel (OIP) w/ Sealed CPU and Mounting Bracket

General
Touchscreen shall function properly with a Flash Fire Glove.

General

Shall include Section 3.1 item 8 removable Sealed CPU.

General
Shall include bulkhead mounting bracket and bracket to equipment mounting hardware.
Enclosure
Dust and water resistance shall be IP65 (Reference IEC 60529).
Door
Shall consist of a complete integral unit with a hinged bezel for maintenance efforts.
Door
Bezel shall be able to be physically secured using a hasp with lock.
Cooling
Shall have passive cooling (no moving parts).
Physical Security
Shall be lockable.
Display Type
Liquid Crystal Display (LCD)
Backlight
Light Emitting Diode (LED) backlight
Pointer
Shall contain a bezel mounted pointer with right & left click.
Touch Screen
single touch resistive 5+ wire
Resolution
1920x1080
Aspect Ratio
16:9
Glass
2.8mm Tempered Glass
Min Viewing Angle
85° Horizontal & Vertical
Brightness
0-300 nits
Brightness Control
0-100%
Colors
16 Million
Contrast Ratio
5000:1
Material
0.125” Aluminum 5052-H32 Alloy. Chemically treated IAW MIL-DTL 5541, Type II, Class 1A. Material shall not contain hexavalent chromium.
Weight
Not to Exceed (NTE) 60lbs with mount bracket.
Max Power Consumption
NTE 100W
Dimensions
NTE 26.0” (W) x 18” (H) x 12.0” (D) (with mounting)
Mounting Bracket
Tilt Angle: 15 ° Up/Down: Material: .187” Aluminum Plate
USB
Two (2) USB 3.0 external I/O ports
External I/O Ports
All external connections shall have a positive locking mechanism with mating metal dust cap and tether.
Fiber
Fiber Ethernet: Support for a minimum of two (2) 1000BaseLX, 100BaseFX, or 1000BaseSX native fiber NICs (no media converters). Two (2) external cable glands
Copper Ethernet
Three (3) 10/100/1000BaseTX external RJ45 I/O ports
Isolated GPIO/DIO:
Support for a minimum of four (4) DI and four (4) DO.

One (1) DIO/GPIO external I/O port

Power
Voltage: 90-264VAC

Rating: 2x max power consumption

Connector: MS27656T15B5P

Current 2.7A max @ 115VAC

On/Off Switch: Toggle Switch STDP, 15A, Water Tight

Fusing: 2 internal fuses (5A); delta/wye power

Speaker
Minimum 90dB

Minimum volume control shall not be less than10dB

24” OIP Connector Kit

General
Connector kit shall consist of mating connectors and/or cables for all OIP external I/O.

Power

1pc D38999/26WC4SN, Mil-Power Mating Connector

Fiber Ethernet
Shall have two (2) stuffing tubes provided for fiber connections. Field fiber cables shall penetrate the OIP and land to an included internal ST-ST patch panel which provides the mating junction to the fiber ports on the CPU. Fiber jumpers from CPU fiber ports to ST-ST patch panel shall come pre-installed – two Single-mode & two Multimode to account for all flavors of fiber Ethernet.
Copper Ethernet
Mil Spec Connector Support for a minimum of three (3) 10/100/1000BaseTX native copper network interfaces

3 pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors

Isolated GPIO/DIO
Support for a minimum of four (4) DI and four (4) DO Cap: mating metal cap for all OIP box mounted connectors

1pc D38999/26WC35SN, DIO/GPIO Mating Connector

USB
3pc USB3FTV5G Circular Mil-USB 3.0 Mating Connector
Clamps
2pc M85049/38-13W

24” Flat Panel Display (for single & dual monitor consoles)

General
Touch screen shall function properly with a Flash Fire Glove.
General
Shall be integrated into single and dual monitor consoles.
General
Not separately tested. To be tested as part of full assemblies.
Enclosure
Dust and water resistance shall be IP65 (REFERENCE IEC 60529) when mounted.
Cooling
Shall have passive cooling (no moving parts).
Display Type
LCD
Backlight
LED
Touchscreen
Single touch resistive 5 wire
Resolution
1920X1080
Aspect Ratio
16:9
Brightness
0-300 nits
Brightness Control
0-100%
Colors
16 Million
Contrast Ratio
5000:1
Glass
2.8mm Tempered Glass
Min Viewing Angle
85° Horizontal & Vertical
I/O Ports
Standard A-B USB 2.0 for touch interface
Video Inputs
(1) VGA, (1) HDMI, or (1) Display Port
Power
85-264VAC

42” Flat Panel Display (FPD) and Mounting Bracket

General
Touch screen shall function properly with a Flash Fire Glove.
General
Shall operate and interface with Section 3.1 item 18 Operator Interface Computer (OIC) CPU Enclosure 1, Section 3.1 item 20 OIC CPU Enclosure 2, and Section 3.1 item 8 Sealed CPU.
General
Shall include bulkhead mounting bracket and bracket to equipment mounting hardware.
Enclosure
Dust and water resistance shall be IP65 (REFERENCE IEC 60529).
Cooling
Shall have Passive cooling (no moving parts).
Display Type
Non Plasma
Backlight
LED
Touchscreen
IR multi-touch
Resolution
Native 1920X1080
Aspect Ration
16:9
Brightness
0-500 nits
Brightness Control
0-100%
Colors
16 Million
Contrast Ratio
4000:1
Glass
2.8mm Tempered Glass
Min Viewing Angle
85° Horizontal & Vertical
External I/O Ports
Standard A USB 2.0 for touch interface
External I/O Ports
All external connections shall have a positive locking mechanism with mating metal dust cap and tether.
External Video Inputs
(1) HDMI (shall be able to transfer Audio through same cable)
Power
85-264VAC (Power On/Off Switch)
Integrated Speaker w/ Volume Control
110db at 2 feet orthogonal to display (Sound will pass through HDMI)
Weight
NTE 105lbs (with mounting brackets)
Power Consumption
NTE 105W
Dimensions
NTE 45.0 (W) x 29.0 (H) x 7.0 (D) (With Vertical Mounting Bracket)

NTE 45.0 (W) x 29.0 (H) x 15.0 (D) (With 15 ° angled bracket).

Mounting Bracket
Tilt Angle: 15 ° Up/Down

Material: .187” Aluminum Plate, 42” Flat Panel Display Connector (FPD) Kit

General
Connector kit shall consist of mating connectors, back shells, and/or cables for all FPD external I/O.

Power

1pc D38999/26WC4SN, Mil-Power Mating Connector

HDMI Cable
1pc HD-WTP-WMWM-5M, Mating Cable Assembly
USB Cable
1pc USB A-A Black 5 Meters
USB
2pc USBFTV6G, Mating Connector

46” Flat Panel Display (FPD) and Mounting Bracket

General
Touch screen shall work with a Flash Fire Glove.
General
Shall operate and interface with Section 3.1 item 18 Operator Interface Computer (OIC) CPU Enclosure 1, Section 3.1 item 20 OIC CPU Enclosure 2, and Section 3.1 item 8 Sealed CPU.
General
Shall include bulkhead mounting bracket and bracket to equipment mounting hardware.
Enclosure
Dust and water resistance shall be IP65 (REFERENCE IEC 60529).
Cooling
Shall have Passive cooling (no moving parts).
Display Type
Non Plasma
Backlight
LED
Touchscreen
IR multi-touch
Resolution
native 1920X1080
Brightness
0-500 nits
Brightness Control
0-100%
Colors
16 Million
Contrast Ratio
4000:1
Glass
2.8mm Tempered Glass
Min Viewing Angle
85° Horizontal &Vertical
External I/O Ports
Standard A USB 2.0 for touch interface
External I/O Ports
All external connections shall have a positive locking mechanism with mating metal dust cap and tether.
External Video Inputs
(1) HDMI (shall be able to transfer Audio through same cable)
Power
85-264VAC (Power On/Off Switch)
Integrated Speaker w/ Volume Control
90db at 2 feet orthogonal to display (Sound will pass through HDMI)
Weight
NTE 122lbs (With Mounting Bracket)
Power Consumption
NTE 105 W
Dimensions
50.0 (W) x 30.0 (H) x 8.0 (D) (With Vertical Mounting Bracket)

50.0 (W) x 30.0 (H) x 17.0 (D) (With 15 ° angled bracket)

Mounting Bracket
Tilt Angle: 15 ° Up/Down

Material: .187” Aluminum Plate, 46” Flat Panel Display (FPD) Connector Kit

General
Connector kit shall consist of mating connectors, back shells, and/or cables for all FPD external I/O.

Power

1pc D38999/26WC4SN, Mil-Power Mating Connector

HDMI Cable
1pc HD-WTP-WMWM-5M, Mating Cable Assembly
USB Cable
1pc USB A-A Black 5 Meters
USB
2pc USBFTV6G, Mating Connector

Sealed CPU (Latest Generation)

Enclosure
Dust and water resistance shall be IP54.
Cooling
Shall be fan-less, passively cooled, completely solid state without a display, and no moving parts.
General
Shall be fan-less, passively cooled, completely solid state without a display.
Supportability
Hardware shall be in line with Intel’s long term embedded computing roadmap.
Weight
NTE 9lbs
Max Power Draw
90W
Dimensions
11.0”(W) x 4.0”(H) x 7.0”(D)
USB
USB: minimum of four (4) USB 3.0 and two (2) USB 2.0 ports
Fiber
Fiber Ethernet: Support for a minimum of two (2) 1000BaseLX, 100BaseFX, or 1000BaseSX native fiber NICs (no media converters)
Copper Ethernet
Copper Ethernet: Support for a minimum of three (3) 10/100/1000BaseTX
Isolated DIO
Isolated GPIO/DIO: Support for a minimum of four (4) DI and four (4) DO
Power
Input Power: 12V-36 VDC
Power Connector
2-pin Terminal Block: V+, V-
Off Switch
Push Button
CPU
Minimum processor performance requirements shall be Intel® Core Processor i7 3.4 GHz or Greater
TPM
TPM 2.0 or Greater
Memory
16GB RAM (single DIMM low power) expandable to 32GB RAM (single DIMM low power)
Video
Integrated AGP Controller
Video Output
Video Output: Minimum (1) VGA and (1) HDMI or (1) Display port
Sound
Integrated Audio
BIOS
Must allow administrator lockout of USB ports

Must allow administrator password access.

CFast
Cfast: 64 GB Wide-Temp Cfast card, User-Accessible
Storage
Two (2) Solid State Drives with power fail write protection in RAID 1

SSD Drive Capacity (each):

256GB EA SSD Type: Intel Wide-Temp SSD or equivalent

OS
Computers shall be compatible with all of the following: Windows 7 Embedded,

Windows 10 IOT, Windows 11, RHL 7.x and newer

Power Adapter for Sealed CPU

General
Power Adapter shall be a standard power adapter to allow for lab testing. Shall be 120VAC Input, 24VDC Output with standard 120VAC plug on input end and matingplug-in power terminal block on output end.

Sit Down Dual Monitor (SDDM) Console

General
Touch screen shall function properly with flash fire glove.
Console
Dust and Water resistance shall be IP65 (REFERENCE IEC 60529).
Cooling
Shall be passive no moving Parts (fanless).
Keyboard
Shall have full function USB (114 keys).
Trackball
Shall have built-in rugged trackball NEMA compliant.
Monitors
Two (2) integrated Flat Panel Displays
Lower Monitor Viewing Angle
Lower monitor shall mount at a 105-degree viewing angle.
Upper Monitor Viewing Angle
Upper monitor shall mount at a 65-degree viewing angle.
Computer
Shall be compatible with integrating Section 3.1 item 8 Sealed CPU into consoles’ lower bay.
Mounting
The console shall employ a “hard mount” configuration without the use of shock isolation mounts.
Color
FED-STD-595B, No. 26307 light equipment gray.
Access & Security
The console configuration shall provide front access for normal maintenance of the enclosed components and peripherals. Locking capability using a hasp is required.
Cable Penetrations
Bulkhead-type, sealed cable penetrations (Roxtec) shall be used for external cabling. All penetrations shall be made at the side and rear vertical panel no more than 6” from the bottom base and shall not preclude compliance with the referenced environmental requirements.
I/O Panel
Inner I/O panel with positive locking MIL-STD connections for two (2) 10/100/1000BaseTX external RJ45 I/O ports and one (1) primary power port
ID Nameplate
An ID nameplate label shall be secured to the inside console access door. In accordance with MIL-DTL-15024F Type E, MIL-M-43719 Type I adhesive backed film adhered to aluminum alloy sheet. Lettering shall be screen or litho print
PDU
A power distribution unit (PDU) shall be installed. Shall have Power receptacles inside base to allow hook up for computers and monitors
Voltage
Voltage: 85-264VAC
Input Power
90 to 132 VAC Single Phase. (Power On/Off Switch).
Line Frequency
Nominal 60Hz
Power Consumption
NTE 150 W
Integrated Speaker
110 db output with volume control
Max Width
26”
Max Height
69.0” (Not including foundation)
Max Depth
32.0”
Max Weight
340 lbs
Foundation
Hard mounted. Shall mount to existing foundation bolt hole pattern.

SDDM Connector Kit

General
Connector kit shall consist of mating connectors and/or cables for all SDDM external I/O.

Power

1pc D38999/26WC4SN, Mil-Power Mating Connector

Ethernet
2pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors.
Clamp
1pc M85049/38-13W Cable Clamp.

Stand Up Dual Monitor (SUDM) Console

General
Touch screen shall function properly with flash fire glove.
Console
Dust and Water Resistance shall be IP65 (REFERENCE IEC 60529).
Cooling
Shall be passive no moving Parts (fanless).
Keyboard
Shall have full function USB (114 keys).
Trackball
Shall have built-in rugged trackball NEMA compliant.
Monitors
Two (2) integrated 24” Flat Panel Displays.
Lower Monitor Viewing Angle
Lower monitor shall mount at a 75-degree viewing angle
Upper Monitor Viewing Angle
Upper monitor shall mount at a 90-degree viewing angle
Computer
Shall be compatible with integrating Section 3.1 item 8 Sealed CPU into consoles’ lower bay.
Mounting
The console shall employ a “hard mount” configuration without the use of shock isolation mounts
Color
FED-STD-595B, No. 26307 light equipment gray.
Access & Security
The console configuration shall provide front access for normal maintenance of the enclosed components and peripherals. Locking capability using a hasp is required.
Cable Penetrations
Bulkhead-type, sealed cable penetrations (Roxtec) shall be used for external cabling. All penetrations shall be made at the side and rear vertical panel no more than 6” from the bottom base and shall not preclude compliance with the referenced environmental requirements.
I/O Panel
Inner I/O panel with positive locking MIL-STD connections for two (2) 10/100/1000BaseTX external RJ45 I/O ports and one (1) primary power port
ID Nameplate
An ID nameplate label shall be secured to the inside console access door. In accordance with MIL-DTL-15024F Type E, MIL-M-43719 Type I adhesive backed film adhered to aluminum alloy sheet. Lettering shall be screen or litho print
PDU
A power distribution unit (PDU) shall be installed. Shall have Power receptacles inside base to allow hook up for computers and monitors
Voltage
Voltage: 85-264VAC (power on/off switch)
Input Power
90 to 132 VAC Single Phase
Line Frequency
Nominal 60Hz
Power Consumption
NTE 150 W
Integrated Speaker
110 db output with volume control
Max Width
26”
Max Height
80.0. (Not including foundation)
Max Depth
32.0
Max Weight
395 lbs
Foundation
Hard mounted. Shall mount to existing foundation bolt hole pattern.

SUDM Connector Kit

General
Connector kit shall consist of mating connectors and/or cables for all SUDM external I/O.

Power

1pc D38999/26WC4SN, Mil-Power Mating Connector

Ethernet
2pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors.
Clamp
1pc M85049/38-13W Cable Clamp.

Sit Down Single Monitor (SDSM) Console

General
Touch screen shall function properly with flash fire glove.
Console
Dust and Water resistance shall be IP65 (REFERENCE IEC 60529).
Cooling
Shall be passive no moving Parts (fanless).
Keyboard
Shall have full function USB (114 keys).
Trackball
Shall have built-in rugged trackball NEMA compliant.
Monitor
One (1) integrated 24” Flat Panel Display
Monitor Viewing Angle
Monitor shall mount at a 105-degree viewing angle
Computer
Shall be compatible with integrating Section 3.1 item 8 Sealed CPU into consoles’ lower bay.
Mounting
The console shall employ a “hard mount” configuration without the use of shock isolation mounts.
Color
FED-STD-595B, No. 26307 light equipment gray.
Access & Security
The console configuration shall provide front access for normal maintenance of the enclosed components and peripherals. Locking capability using a hasp is required.
Cable Penetrations
Bulkhead-type, sealed cable penetrations (Roxtec) shall be used for external cabling. All penetrations shall be made at the side and rear vertical panel no more than 6” from the bottom base and shall not preclude compliance with the referenced

environmental requirements.

I/O Panel
Inner I/O panel with positive locking MIL-STD connections for two (2) 10/100/1000BaseTX external RJ45 I/O ports and one (1) primary power port
ID Nameplate
An ID nameplate label shall be secured to the inside console access door. In accordance with MIL-DTL-15024F Type E, MIL-M-43719 Type I adhesive backed film adhered to aluminum alloy sheet. Lettering shall be screen or litho print
PDU
A power distribution unit (PDU) shall be installed. Shall have Power receptacles inside base to allow hook up for computers and monitors
Voltage
Voltage: 85-264VAC
Input Power
90 to 132 VAC Single Phase (power on/off switch)
Line Frequency
Nominal 60Hz
Power Consumption
NTE 120 W
Max Width
26”
Max Height
54.0” (Not including foundation)
Max Depth
32.0”
Max Weight
320 lbs
Foundation
Hard mounted. Shall mount to existing foundation bolt hole pattern.

SDSM Connector Kit

General
Connector kit shall consist of mating connectors and/or cables for all SDSM external I/O.

Power

1pc D38999/26WC4SN, Mil-Power Mating Connector

Ethernet
2pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors.
Clamp
1pc M85049/38-13W Cable Clamp.

SUSM Console

General
Touch screen shall function properly with flash fire glove.
Console
Dust and Water resistance shall be IP65 (REFERENCE IEC 60529).
Cooling
Shave be passive no moving Parts (fanless).
Keyboard
Shall have full function USB (114 keys).
Trackball
Shall have built-in rugged trackball NEMA compliant.
Monitor
One (1) integrated 24” Flat Panel Display console
Monitor Viewing Angle
Monitor shall mount at a 75-degree viewing angle
Computer
Shall be compatible with integrating Section 3.1 item 8 Sealed CPU into consoles’ lower bay.
Mounting
The console shall employ a “hard mount” configuration without the use of shock isolation mounts
Color
FED-STD-595B, No. 26307 light equipment gray.
Access & Security
The console configuration shall provide front access for normal maintenance of the enclosed components and peripherals. Locking capability using a hasp is required.
Cable Penetrations
Bulkhead-type, sealed cable penetrations (Roxtec) shall be used for external cabling. All penetrations shall be made at the side and rear vertical panel no more than 6” from the bottom base and shall not preclude compliance with the referenced environmental requirements.
I/O Panel
Inner I/O panel with positive locking MIL-STD connections for two (2) 10/100/1000BaseTX external RJ45 I/O ports and one (1) primary power port
ID Nameplate
An ID nameplate label shall be secured to the inside console access door. In accordance with MIL-DTL-15024F Type E, MIL-M-43719 Type I adhesive backed film adhered to aluminum alloy sheet. Lettering shall be screen or litho print
PDU
A power distribution unit (PDU) shall be installed. Shall have Power receptacles inside base to allow hook up for computers and monitors
Voltage
Voltage: 85-264VAC
Input Power
90 to 132 VAC Single Phase (power on/off switch)
Line Frequency
Nominal 60Hz
Power Consumption
NTE 120 W
Max Width
26”
Max Height
63” (Not including foundation)
Max Depth
32.0”
Max Weight
375 lbs
Foundation
Hard mounted. Shall mount to existing foundation bolt hole pattern.

SUSM Connector Kit

General
Connector kit shall consist of mating connectors and/or cables for all SUSM external I/O.

Power

1pc D38999/26WC4SN, Mil-Power Mating Connector

Ethernet
2pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors.
Clamp
1pc M85049/38-13W Cable Clamp.

Operator Interface Computer (OIC) CPU Enclosure Configuration 1 and Mounting Bracket

General
The enclosure shall be fanless, passively cooled, and without a display.
General
The enclosure shall house and mount Section 3.1 item 8 removable Sealed CPU with respective connector kits.
General
Shall integrate with 46” and 42” Flat Panel Displays providing video, audio and touch receiving touch screen inputs with all required Operating Systems.
General
Shall include bulkhead mounting bracket and bracket to equipment mounting hardware.
Enclosure
Dust and Water Resistance shall be IP65 (REFERENCE IEC 60529).
Physical Security
Shall be lockable with a hasp
Power
Voltage: 90-264VAC

Rating: 2x max power consumption

Connector: MS27656T15B5P

Current 2.7A max @ 115VAC

On/Off Switch: Toggle Switch STDP, 15A, Water Tight

CPU ON/OFF Switch

Fusing: 2 internal fuses (5A); delta/wye power

Foundation
Shall be hard mounted.
External Connection Ports
1 x MIL-STD Power Connector

2 x Circular MIL-STD RJ45 Ethernet Connectors

2 x Fiber Cable Glands

1 x Circular MIL-STD USB 3.0 Connector 1 x Circular MIL-STD HDMI Output

External I/O Ports
All external connections shall have a positive locking mechanism with mating metal dust cap and tether.
Input Power
90 to 132 VAC Single Phase
Line Frequency
Nominal 60Hz
Power Consumption
70W
Weight
NTE 35 lbs
Dimensions
15” (W) x 17” (H) x 11” (D) (With Mounting Bracket)

Operator Interface Computer (OIC) CPU Enclosure 1 Connector Kit

General
Connector kit shall consist of mating connectors, back shells, and/or cables for all external I/O.

Power

1pc D38999/26WC4SN, Mil-Power Mating Connector

Ethernet
2pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors.
HDMI Cable
1pc HD-WTP-WMWM-5M HDMI

Cords Set, IP67 Molded

USB
1pc USBFTV6G, Mating Connector
Clamp
1pc M85049/38-13W Cable Clamp.

Operator Interface Computer (OIC) CPU Enclosure Configuration 2 and Mounting Bracket

General
The enclosure shall be fanless, passively cooled, and without a display.
General
The enclosure shall house and mount Section 3.1 item 8 removable Sealed CPU with respective connector kits.
General
Shall integrate with 46” and 42” Flat Panel Displays providing video, audio and touch receiving touch screen inputs with all required Operating Systems.
General
Shall include bulkhead mounting bracket and bracket to equipment mounting hardware.
Enclosure
Dust and Water Resistance shall be IP65 (REFERENCE IEC 60529).
Physical Security
Shall be lockable with a hasp
Speaker
93 dB Speaker
Power
Voltage: 90-264VAC

Rating: 2x max power consumption

Connector: MS27656T15B5P

Current 2.7A max @ 115VAC

On/Off Switch: Toggle Switch STDP, 15A, Water Tight

CPU ON/OFF Switch for Soft Shutdown with RED indicator

Fusing: 2 internal fuses (5A); delta/wye power

Foundation
Shall be hard mounted.
External Connection Ports
1 x MIL-STD Power Connector

2 x Circular MIL-STD RJ45 Ethernet Connectors

1 x Circular MIL-STD VGA Video Output

1 x Circular MIL-STD HDMI output

4 x Circular MIL-STD USB 3.0 Connector

2 x Fiber Cable Glands

External I/O Ports
All external connections shall have a positive locking mechanism with mating metal dust cap and tether.
Input Power
90 to 132 VAC Single Phase
Line Frequency
Nominal 60Hz
Power Consumption
85W
Dimensions
15” (W) x 17” (H) x 11” (D) (With Mounting Bracket)
Max Weight
40 lbs

Operator Interface Computer (OIC) CPU Enclosure 2 Connector Kit

General
Connector kit shall consist of mating connectors, back shells, and/or cables for all external I/O.

Power

1pc D38999/26WC4SN, Mil-Power Mating Connector

Ethernet
2pcs RJFTV6MG RJ45 Circular Mil-Ethernet Mating Connectors.
HDMI Cable
1pc HD-WTP-WMWM-5M HDMI

Cords Set, IP67 Molded

USB
4pc USBFTV6G, Mating Connector
Clamp
1pc M85049/38-13W Cable Clamp.

Rugged External Keyboard and Mounting Bracket

General
The keyboard shall have an integrated trackball device and three (3) control buttons. Keyboard shall and 24 function keys.
General
Shall include bulkhead mounting bracket and bracket to equipment mounting hardware.
General
Bulk-head Mounted
Mounting Bracket
Shall include a single bulkhead mounting bracket for both the OIP and Rugged Keyboard.
Keyboard
The keyboard shall be at a 15 degree angle.
Color
Equipment Grey FED-STD-595, COLOR NO. 26307
Dimensions
26.0” (W) x 25.0” (H) x 18.0 (D) (With Mounting Bracket)
Weight
NTE 25lbs (Including Mounting)

UPS Rack Mounted Requirements

Series
PS6000
Enclosure
Stainless steel cabinet
Mounting
Rack 3U Max w/ Rail Kit
Weight
NTE 100lbs
Power
1.5KVA and 984W Output
Power Consumption
10A
Outputs/Inputs
2 MIL outputs and 1 MIL input
Communication
9640 SNMP card
Batteries
Premium H batteries
Bypass
Master Bypass rotary knob
Connector shall mate to
2 x Ms3106r16-10p

1 x Ms3106r16-10s

Max Width
19”
Max Height
5.25”
Max Depth
20”

UPS Mini Tower Requirements

Series
PS1504
Enclosure
Stainless steel cabinet
Mounting
Front face hull mount
Weight
NTE 66 lbs
Power
1.5KVA and 984W Output
Power Consumption
10A
Outputs/Inputs
2 MIL outputs and 1 MIL input
Communication
9640 SNMP card
Batteries
Premium H batteries
Bypass
Master Bypass rotary knob
Foundation
Shall be compatible with UPS Mini Tower Foundation Section 3.1 item 25.
Connector shall mate to
2 x Ms3106r16-10p

1 x Ms3106r16-10s

Max Width
6.73”
Max Height
8.62”
Max Depth
17.28”

UPS Mini Tower Foundation

Foundation
Bulkhead mounted
Foundation
Shall be compatible with UPS Mini Tower PS1504 Section 3.1 item 24.
General
Shall include bulkhead mounting bracket and bracket to equipment mounting hardware.
Weight
NTE 10lbs
Max Width
10”
Max Height
10”
Max Depth
20”

UPS Rack Mounted and UPS Mini Tower Input Connector Kit

General
1 x Ms3106r16-10s

UPS Rack Mounted and UPS Mini Tower Output Connector Kit

General
1 x Ms3106r16-10p

Modification kit for RGB video connection

General
Shall provide a console MOD kit for RGB video to be streamed to outside video.
General
Shall provide a console MOD kit for a physical external connection for RGB connections.

4.0 DATA REQUIREMENTS

4.1 The Contractor shall provide the following CDRLs at the required periodicity.

· CDRL A001, Shock Test Procedures

· CDRL A002, Vibration Test Procedures

· CDRL A003, EMI Test Procedures

· CDRL A004, Shock Test Report

· CDRL A005, Vibration Test Report

· CDRL A006, EMI Test Report

· CDRL A007, Power Test Procedures

· CDRL A008, Power Test Report

· CDRL A009, Environmental Engineering Test Procedures

· CDRL A010, Environmental Engineering Test Report

· CDRL A011, As Built Configuration List

· CDRL A012, Equipment Technical Manual

· CDRL A013, Production Drawings/Models and Associated Lists

5.0 SECURITY REQUIREMENTS

5.4 OPERATIONS SECURITY (OPSEC)

5.4.1 The Contractor shall protect critical information associated with this contract to prevent unauthorized disclosure. The NSWC Philadelphia Division's (NSWCPD) Critical Information List (CIL)/ CIIL (Critical Indicators and information list) will be provided on site, if warranted. Performance under this contract requires the contractor to adhere to OPSEC requirements. The Contractor may not impose OPSEC requirements on its subcontractors unless NSWCPD approves the OPSEC requirements. During the period of this contract, the Contractor may be exposed to, use, or produce, NSWCPD Critical Information (CI) and/or observables and indicators which may lead to discovery of CI. NSWCPD’s CI will not be distributed to unauthorized third parties, including foreign governments, or companies under Foreign Ownership, Control, or Influence (FOCI) unless such FOCI has been appropriately mitigated through measures approved by the Defense Counterintelligence and Security Agency. Questions concerning these requirements shall be directed to the PCO.

5.4.2 CUI correspondence transmitted internally on the contractor's unclassified networks or information systems, and externally, shall be protected per NIST SP-800-171, Protecting Controlled Unclassified Information (CUI) in Non-federal Systems and Organizations.

Assembled large components/systems being transported to and from testing areas, other production or government facilities (whether or not on public roadways) shall be in an enclosed van trailer or covered flatbed trailer. Component/System outside storage, staging, and test areas shall be shielded/obscured from public view wherever physically possible.

5.4.3 NSWCPD’s CI shall not be publicized in corporate wide newsletters, trade magazines, displays, intranet pages or public facing websites. Media requests related to this project shall be directed to the PCO, and the COR who will forward the required to the NSWCPD Public Release Authority for review.

5.4.4 Any attempt by unauthorized third parties to solicit, obtain, photograph, or record, or; incidents of loss/compromise of government Classified or CI, Business Sensitive, Company Proprietary information related to this or other program must be immediately reported to the contractor's Facility Security Officer and Cognizant Security Office and/or the Naval Criminal Investigative Service, and the NSWC PD Security Division (Code 105).

5.5 RECEIPT, STORAGE, AND GENERATION OF CONTROLLED UNCLASSIFIED INFORMATION (CUI) All Controlled Unclassified Information (CUI) associated with this contract must follow the minimum marking requirements of DoDI 5200.48, Section 3, paragraph 3.4.a, and include the acronym "CUI" in the banner and footer of the document. In accordance with DoDI 5200.48, CUI must be safeguarded to prevent Unauthorized Disclosure (UD). CUI export controlled technical information or other scientific, technical, and engineering information must be marked with an export control warning as directed in DoDI 5230.24, DoDD 5230.25, and Part 250 of Title 32, CFR. Nonfederal information systems storing and processing CUI shall be protected per NIST SP-800-171, or subsequent revisions. All transmissions to personal email accounts (AOL, Yahoo, Hotmail, Comcast, etc.) and posting on social media websites (Facebook, Instagram, Twitter, LinkedIn, etc.) are prohibited. Destroy CUI associated with this contract by any of the following approved methods: A cross-cut shredder; a certified commercial destruction vendor; a central destruction facility; incineration; chemical decomposition; pulverizing, disintegration; or methods approved for classified destruction.

6.0 PLACE OF PERFORMANCE

Delivery shall be identified at the issuance of the delivery order.

7.0 TRAVEL

Not applicable.

8.0 GOVERNMENT FURNISHED PROPERTY

Not applicable.

9.0 GOVERNMENT FURNISHED INFORMATION

Not applicable.

10.0 PURCHASES

Not applicable.

11.0 Counterfeit Material Prevention

Not applicable.

12.0 PERSONNEL

Not applicable.

13.0 NSWCPD Electronic Cost Reporting and Financial Tracking (eCRAFT) System

Not applicable.

14.0 SPECIAL REQUIREMENTS

Contractor shall provide documentation that verifies all requirements in the Statement of Work are met through operational verification when possible or inspection.

Contractor shall perform interface verification testing between OIC CPU Enclosure 1 and OIC CPU Enclosure 2 with 42” FPD and 46” FPD to ensure all I/O is functioning properly using all required Operating Systems in the Statement of Work. For example all video, audio, and touch screen capabilities shall be verified with each Operating System.

Contractor shall verify each delivered equipment meets the requirements in the Statement of Work and provide documentation to the Government.

15.0 WARRANTY

Contractor shall provide a 12 month warranty from the time of initial shipboard installation and power-up Not to Exceed (NTE) 36 months from receipt of equipment. Receipt inspection of contract items shall not start the official warranty period for procured items.

SOW-PWS Template 30 June 2022 version

File details come from the government source that posted it. Updated .