This is an architectural specification document for Delton Kellogg Schools in Delton, Michigan, prepared by GMB Architect + Engineer for the High School Locker Replacement project (A/E Project 5-4900). The project involves furnishing and installing steel lockers in the high school's athletic and physical education locker room areas. The scope of work requires replacement lockers to be installed on existing bases in the locations of current lockers, with all accessories, locks, and numbers included and ready for operational use. Two locker types are specified: heavy-duty ventilated lockers measuring 15 inches wide by 15 inches deep by 72 inches high for athletic locker rooms, and heavy-duty ventilated lockers measuring 10 inches wide by 15 inches deep by 72 inches high for physical education locker rooms, all in single-tier configuration with flat tops. The document references a first-floor plan dated June 10, 2019, and specifies that contractors must field-measure all locations and verify existing conditions prior to fabrication.
Acceptable manufacturers for the metal lockers include Republic Storage Systems, Inc., Lyon Metal Products, Incorporated, Penco Products, Interior/Medart, Hadrian, Inc., Art Metal Products, and DeBourgh. All lockers must comply with 2010 ADA Standards for Accessible Design, with a minimum of 5 percent accessible lockers of each type dispersed throughout the installation. The specification requires mild annealed, cold-rolled steel construction with cadmium-plated or rust-retardant bolts, seven-stage phosphatization process, and baked enamel finish at 300 degrees for 30 minutes with color selected by the architect. All lockers must include polished aluminum number plates, interior shelving, hooks, heavy-duty hinges, and positive automatic pre-locking devices. Contractors are responsible for patching compromised walls with like materials, maintaining existing partition ratings, and coordinating all work with the site superintendent. A minimum two-year warranty against defects for materials and installation is required.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| High School Air Conditiong and Lockers.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OWNER
GMB Project #
Printed On Recycled Paper
VICINITY MAP
DELTON KELLOGG SCHOOLS
327 N. GROVE ST, DELTON, MI 49046
P. 269.623.1500 www.dkschools.org
MAP BY GOOGLE
GMB
ARCHITECT + ENGINEER
ARCHITECTURE + ENGINEERING
85 East Eighth Street, Suite 200, Holland, MI 49423 P. 616.796.0200 F. 616.796.0201 www.gmb.com
C :\L oc al
P ro je ct s\ 5-
A
_C
EN
TR
AL
_e rin m
.rv t
DELTON KELLOGG HIGH SCHOOL
DELTON KELLOGG SCHOOLS
DELTON, MICHIGAN
5-4900
10425 PANTHER PRIDE
ARCHITECTURAL
A2.1A UNIT 'A' FIRST FLOOR PLAN
06.10.2019
BIDS & CONSTRUCTION
11 11
15 17
15 17
9 9 9 9
26 11
26 11
ATHLETICS
PT
OFFICE
PT
OFFICE
PT
OFFICE
PT
PE
PT
ATHLETICS
PT
OFFICE
PT
PE
PT
NOTE: CONTRACTOR TO FIELD
MEASURE ALL LOCATIONS AND
VERIFY EXISTING CONDITIONS.
REUSE EXISTING BASES.
A2.1A
Sim
NEW BASE
A2.1A
Sim
A2.1A
Sim
A2.1A
SimNEW BASE
NE
W
B
AS
E
NE
W
B
AS
E
NEW BASE
NE
W
B
AS
E
A2.1A
Sim
A2.1A
Sim
3/4" PLYWOOD x 4" WIDE
CONTINUOUS AT LOCKER
ANCHOR POINT BY LOCKER
CONTRACTOR IF REQUIRED
METAL LOCKER - SEE
SPECIFICATIONS
RUBBER WALL BASE
LOCKER TOP - SEE
SPECIFICATIONS
1/2" PLYWOOD ANCHORED TO
2x4 TREATED WOOD BASE SECURED TO 2x4 P.T. FRAMING
AT 24" O.C. (LAID FLAT) AND ANCHORED WITH
(2) 1/2" DIA. EXP. ANCHORS PER BOARD
LO
CK
ER
H
EI
GH
T
SE
E
SP
EC
IF
. F
OR
4"
GENERAL FLOOR PLAN NOTES:
1. DIMENSIONS GIVEN ARE TO THE FACE OF MASONRY UNITS OR TO THE FINISHED FACE OF METAL STUD PARTITION WALLS.
2. FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OF ANY CABINETRY, FRAMES, STRUCTURAL ITEMS, ETC.
3. PROVIDE PAINTED ACCESS PANELS IN WALLS AND CEILINGS TO PROVIDE ACCESS TO CONCEALED ITEMS INCLUDING BUT NOT LIMITED TO VALVES, CONTROLS, MECH. EQUIPMENT ETC. ACCESS PANELS MAY NOT ALWAYS BE SHOWN ON PLANS. IT IS THE SUB CONTRACTOR RESPONSIBILITY TO DETERMINE LOCATIONS. COORDINATE LOCATIONS WITH OTHER GENERAL
CONTRACTOR / SITE SUPERVISOR.
4. CONTRACTOR TO MAINTAIN / REPAIR RATING OF EXISTING PARTITIONS AS AFFECTED BY DEMOLITION / NEW
CONSTRUCTION. TYPICAL THROUGHOUT.
5. WALLS TO BE PATCHED WITH LIKE MATERIALS WHERE EXISTING WALLS HAVE BEEN COMPROMISED FROM DEMOLITION. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO REMOVAL AND REINSTALLATION OF CASEWORK AND WALL MOUNTED EQUIPMENT IN ORDER TO ACHIEVE SAID PATCH. IN AREAS WHERE BLOCK OR BRICK HAVE BEEN USED, NEW MASONRY TO BE TOOTHED IN AND MATCH EXISTING. AREAS AND FINISHES IN QUESTION SHALL BE COORDINATED WITH
ARCHITECT.
PT = PAINT
PROJECT NO.
DRAWN
REVIEWED
GMB
No part of this drawing may be used or reproduced in any form or by any means, or stored in a database or retrieval system, without prior written permission of
Copyright 2019 All Rights Reservedc
ARCHITECTURE + ENGINEERING
85 East Eighth Street, Suite 200
P. 616.796.0200 F. 616.796.0201
HOLLAND LAB
www.gmb.com
Holland, Michigan 49423
648 Monroe Avenue, N.W. Suite 500
GRAND RAPIDS LAB
Grand Rapids, Michigan 49503
310 North Alabama Street, Suite 230
INDIANAPOLIS LAB
Indianapolis, Indiana 46204
225 South Main Street, Suite 200
ROYAL OAK LAB
Royal Oak, Michigan 48067
C :\L oc al
P ro je ct s\ 5-
A
_C
EN
TR
AL
_e rin m
.rv t
6/
/2
8:
:5
AM
A2.1A
5-4900
UNIT 'A' FIRST FLOOR PLAN
EM
BJP
D E
LT
O
N K
E
LL
O G
G H
IG
H
S C
H O
O L
D E
LT
O
N K
E
LL
O G
G S
C H
O O
LS
D
E
LT
O N
M
IC
H
IG
A
N
NORTH
1/8" = 1'-0"
UNIT 'A' FIRST FLOOR PLAN
06.10.2019 BIDS &
CONSTRUCTION
A2.1A 1 1/2" = 1'-0"
1 WOOD LOCKER BASE DETAIL
SECTION 10 51 13
METAL LOCKERS
DELTON KELLOGG SCHOOLS
HIGH SCHOOL LOCKER ROOM LOCKER REPLACEMENT
A/E PROJECT 5-4900
SECTION 10 51 13 - METAL LOCKERS
PART 1 - GENERAL
1.1 SUMMARY
A. Scope of Work: Furnish and install steel lockers where shown on the Drawings, complete with all accessories, locks, numbers, etc. ready for use by Owner.
1.2 SUBMITTALS
A. Product Data, Shop Drawings, Samples: Provide Shop Drawings indicating materials of lockers, supports, anchorage, dimensions and manufacturers installation instructions.
1.3 DELIVERY, STORAGE, AND HANDLING
A. Packing and Shipping: Deliver items in manufacturer’s original unopened protective packaging.
B. Storage and Protection:
1. Store materials in original protective packaging to prevent soiling, physical damage or wetting.
2. Handle so as to prevent damage to finished surfaces.
1.4 SEQUENCING AND SCHEDULING
A. Coordinate all work with job site superintendent and all applicable trades.
1.5 WARRANTY
A. Provide minimum two (2) year warranty against defects for materials and installation, unless otherwise indicated.
PART 2 - PRODUCTS
2.1 ACCEPTABLE MANUFACTURERS
A. Republic Storage Systems, Inc., Canton, Ohio; Lyon Metal Products, Incorporated, Aurora, Illinois; Penco Products, Oaks, Pennsylvania; Interior/Medart; Hadrian, Inc.; Art Metal Products;
and DeBourgh.
2.2 PERFORMANCE REQUIREMENTS
A. Accessibility Standard: For lockers indicated to be accessible, comply with applicable provisions in the USDOJ's "2010 ADA Standards for Accessible Design" the ABA standards of the Federal agency having jurisdiction and ICC A117.1. Unless otherwise indicated on drawings, provide a minimum of 5 percent accessible lockers of each type, dispersed throughout the installation.
Coordinate with Architect.
2.3 MATERIALS
A. Mild annealed, cold rolled steel free from surface imperfections. Bolts to be cadmium plated or subjected to other rust-retardant treatment.
B. Lockers in athletic locker rooms areas shall be heavy duty ventilated type, 15”w x 15”d x 72”h, single tier, with flat tops.
C. Lockers in PE locker rooms shall be heavy duty ventilated type, 10”w x 15”d x 72”h, single tier, with flat tops.
The specifications that follow are based on the standard corridor locker and heavy duty vented locker, both by Republic Storage Systems.
DELTON KELLOGG SCHOOLS
2.4 FABRICATION
A. Corridor Lockers:
1. Material: All parts shall be made of mild cold rolled sheet steel. All steel to be free from imperfections and capable of taking a high grade enamel finish.
2. Finish: Before enamel is applied, the surfaces of the steel shall be thoroughly cleaned and phosphatized in a seven stage process. All parts shall then be finished with a heavy coat of enamel. Enamel shall be baked on at 300 degrees for 30 minutes. Color to be selected by the Architect from manufactures standard color selection. Bottoms shall be galvanealed steel or two (2) coats corrosion resistant paint and warranted for 10 years against rust under normal use.
3. Trim and Accessories: Trim and accessories, such as sloping tops, shall be finished to match lockers using the same process outlined above.
4. Tops shall be 18 gauge.
5. Hinges: Shall be at least a 2” high, 5-knuckle, full loop, tight pin style, to be securely welded to frame and riveted to the inside of the door flange.
6. Number Plates: Each locker shall have a polished aluminum number plate with black numerals not less than ½” high. Plates to be attached with rivets.
7. Interior Equipment: Single tier lockers shall have one hat/book shelf. All single, double and triple tier lockers shall have one double prong (single prong in 9” width) back hook and two single prong wall hooks in each compartment. All hooks shall be made of steel, formed with ball points, zinc-plated and attached with two bolts or rivets.
8. Door Frames: Shall be 16 gauge formed into deep, 1” face channel shapes with a continuous vertical door strike integral with the frame on both sides of the door opening.
Cross frame members of 16 gauge channel shapes including intermediate cross frame on double and triple tier lockers shall be securely welded to vertical framing members to ensure rigidity.
9. Doors: Doors shall be 16 gauge steel formed with a full channel shape on the lock side to fully conceal the lock bar, channel formation on the hinge side and right angle formations across the top and bottom. Doors shall have diamond perforations for venting.
10. Locking Device: Shall be positive, automatic, pre-locking type, whereby the locker may be locked while door is open, then closed without unlocking and without damaging locking mechanism.
11. Latching: Shall be a one-piece, pre-lubricated, spring steel latch completely contained within the lock bar, under tension, to provide a rattle-free operation. the lock bar shall be of pre-painted, double-channel steel construction. The lock bar shall be securely contained in the door channel by self-lubricating polyethylene guides that isolate the lock bar from metal-to-metal contact with the door. There shall be three latching points on single tier lockers and two latching points for each door on two, three and four tier lockers. The lock bar travel is limited by contacting resilient high-quality elastomeric cushioning devices located inside the lock bar.
12. Recess Handle: A non-protruding lifting feature shall be provided for actuating the lock bar when opening the door. It shall be contained in a formed 20 gauge stainless steel pocket that is securely assembled to the door. This pocket also provides a recessed area for accommodating the various lock types and the number plate. The lifting trigger within the recess pocket is an integral part of the steel slide plate which is securely attached to the lock bar and functions to transfer the lifting force. The exposed portion of the lifting trigger is encased in a molded ABS thermoplastic cover.
DELTON KELLOGG SCHOOLS
13. Frame Hooks - Silencers: Frame hooks to accept latching shall be of heavy gauge steel, set close in and welded to the door frame. Continuous vertical door strike shall protect frame hooks from door slam damage. A soft rubber silencer shall be provided and securely installed on each frame hook.
14. Body: The body of the locker consists of 24 gauge upright sheets, backs, tops, bottoms and shelves. Tops, bottoms and shelves are flanged on all four sides. Backs are flanged on two sides. Uprights shall be offset at the front and flanged at the rear to provide a double lapped rear corner. All bolts and nuts shall be zinc plated and tamper resistant.
15. 16 gauge Box End Panels with a 1” face are to be installed in any locations with exposed ends of locker banks.
16. Filler Panels: No wider than 2”
PART 3 - EXECUTION
3.1 INSTALLATION
A. Install lockers on existing bases and in the locations of the existing lockers.
B. Anchoring: Anchored floor and wall.
C. Installation per manufacturer’s recommendations.
END OF SECTION