This performance specification outlines requirements for a handheld radio test set (HHRTS) to replace an outdated system. Key requirements for the HHRTS include a frequency range of 1.5 MHz to 6 GHz, internal rechargeable batteries with over two hours of operation, MIL-STD-810 environmental compliance, and the ability to test receivers, transmitters, and antennas of tactical radios. The HHRTS must fit within defined dimensions and weight limits and include carrying cases, accessories, and the ability to automate testing functions through scripting. Responses to a related request for information are due by March 31, 2022 and should not exceed twenty pages excluding proprietary data markings and four pages of administrative information. The United States Marine Corps seeks this replacement HHRTS through full and open competition to support the Program Manager Supply & Maintenance Systems.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
3. Requirements.
3.1 SYSTEM ARCHITECTURE. All Test Set internal instrumentation shall utilize open source protocols for communication. (Example: SCPI, TCP, RS-232 etc.)
3.2 RF SIGNAL GENERATOR.
The output port shall have the following specifications:
| a. Frequency range: | 1.5 MHz to 6000 MHz | ||||||||
| b. Frequency resolution: | 1 Hz | ||||||||
| c. Accuracy: | Identical Reference Oscillator | ||||||||
| d. Ports output level range: | -120 dBm to -30 dBm | ||||||||
| e. Ports Impedance: | 50 Ohms with VSWR < 1.4 | ||||||||
| f. RF output level accuracy: | +/- 2 dB for > -100 dBm, +/- 3 dB for < -100 dBm | ||||||||
| g. RF output spectral purity: | |||||||||
| g.1 | Residual FM < 20 Hz RMS, post det. BW 3 kHz | ||||||||
| g.2 | Residual AM < 0.20 % RMS, post det. BW 15 kHz | ||||||||
| h. RF output SSB phase noise: | |||||||||
| h.1 | < -84 dBc/Hz at 20 kHz from output at 1000 MHz | ||||||||
| h.2 | < -81 dBc/Hz at 20 kHz from output at 2000 | MHz | h.3 | < -74 dBc/Hz at 20 kHz from output at 6000 MHz | |||||
| i. RF output Harmonics: | < -30 dBc | ||||||||
| j. RF output non-harmonics: | < -50 dBc | ||||||||
| k. RF output resolution: | 1 dB |
3.3 RF SIGNAL MODULATION.
The Test Set shall provide the capability to modulate the RF signal output with frequency, amplitude and Digital IQ modulation. The Test Set shall provide for the ability to modulate the carrier with two simultaneous like audio waveforms.
| The Test Set FM modulation capability shall have the following specifications: | |||||
| a. Carrier frequency range: | 1.5 MHz to 6000 MHz | ||||
| b. FM deviation range: | 100 Hz to 100 kHz | ||||
| c. FM accuracy: | 5% of setting for +/- 1 kHz to +/- 20 kHz deviation | ||||
| d. FM deviation rates: | 10 Hz to 40 kHz | ||||
| e. FM resolution: | 1 Hz for rate and deviation | ||||
| f. FM internal waveform: | Sine | ||||
| g. FM total harmonic distortion: | < 1.0 % | ||||
| h. Modulation source: | Internal | ||||
| i. Modulation Source | The Test Set shall provide the capability to modulate the RF signal output with the following: | ||||
| i.1 | Frequency | ||||
| i.2 | Amplitude | ||||
| i.3 | Digital IQ | ||||
| j. The Test Set shall provide for the ability to modulate the carrier with two simultaneous like audio waveforms. |
3.3.1 AM Modulation.
The Test Set AM modulation capability shall have the following specifications:
| a. Carrier frequency range: | 1.5 MHz to 6000 MHz | ||||
| b. AM modulation range: | 1% to 95% | ||||
| c. AM accuracy: | 5% of setting between 10% and 90% modification | ||||
| d. AM modulation rates: | 15 Hz to 20 kHz | ||||
| e. AM internal waveform: | Sine | ||||
| f. AM total harmonic distortion: | < 3% between 30% and 90% modulation level | ||||
| g. Modulation source: | Internal | ||||
| h. AM resolution: | 1 Hz rate and 1% level | ||||
| i. USB: | The ability to produce USB | ||||
| j. LSB | The ability to produce LSB |
3.3.2 Digital Modulation.
a. The Test Set shall have a Digital (I/Q) modulation capability that allows the user the ability to perform inspection and test of communication sets.
b. Accept software upgrades to allow the test of additional modulation types.
3.4 RF RECEIVER.
The Test Set shall provide an RF measuring receiver with the following specifications:
| a. Frequency range: | 1.5 MHz to 6000 MHz | ||
| b. Receiver sensitivity: | Ant port: 10 dB SINAD with -100 dBm input | ||
| c. IF bandwidths: | Instantaneous IF bandwidth 10 MHz | ||
| d. Audio filters | |||
| d.1 | 3 kHz LP | ||
| d.2 | 15 kHz LP | ||
| d.3 | 300 Hz - 3 kHz BP | ||
| d.4 | C-MSG BP | ||
| d.5 | CCITT BP | ||
| d.6 | NONE | ||
| e. RF Signal Generator Port: | The Receiver shall be available on the same port as the RF Signal Generator | ||
| f. Antenna Port: | The RF Receiver shall be available through an antenna port |
3.4.1 RF Receiver Capability.
The Test Set RF measuring receiver shall have the capability of demodulating all waveforms produced by the RF signal generator.
3.4.2 Software-Upgradeable.
The measuring receiver shall be software-upgradeable to demodulate other modulation types in the future.
3.4.3 Frequency Modulation Meter.
The Test Set shall provide a frequency modulation meter with the following specifications:
a. Range: 0 to 100 kHz
b. Accuracy:
| b.1 | +/- 10.0% plus source residual, +/- 1 count | ||
| b.2 | 1 kHz to 100 kHz FM deviation | ||
| b.3 | Modulation Rate 1 kHz to 20 kHz | ||
| c. Resolution: | 1 Hz | ||
| d. Modulation rate: | 10 Hz to 20 kHz | ||
| e. Input signal level: | > -70 dBm | ||
| f. Measurement Type: | Peak +, Peak – |
3.4.4 Amplitude Modulation Meter.
The Test Set shall provide an amplitude modulation meter with the following specifications:
| a. Range: | 0% to 100% | ||
| b. Accuracy: | +/- 5.0% from 30% to 90% | ||
| c. Resolution: | 1% | ||
| d. Modulation rate range: | 100 Hz to 40 kHz | ||
| e. Input signal level: | > -70 dBm | ||
| f. Measurement Type: | Peak +, Peak - |
3.4.5 Digital Signal Analyzer. The Test Set shall provide a Digital Signal Analyzer with the following specifications:
| a. Range: | 1.5 MHz to 6000 MHz | ||
| b. Modulation Bandwidth: | 10 MHz | ||
| c. Measurement Type: | EVM with constellation diagram. |
3.4.6 RF Frequency Counter and Frequency Error Meter. The Test Set shall provide an RF frequency counter and a frequency error meter function with the following specifications:
| a. Range: | 1.5 MHz to 6000 MHz | |||
| b. Accuracy: | Identical to Reference Oscillator | |||
| c. Resolution: | 1 Hz | |||
| d. Carrier level: | > -70 dBm | |||
| e. Frequency error meter range: | +/- 0 Hz to +/- 1000 kHz | |||
| f. Frequency error meter resolution: | 1 Hz | |||
| g. Frequency error meter carrier level: | > -70 dBm |
3.4.7 RF Power Meter. The Test Set shall provide an RF power meter with the ability to incorporate external attenuation into the power calculation to allow testing of high power radios. The Test Set shall have the following specifications:
| a. Frequency range: | 1.5 MHz to 6000 MHz | ||||
| b. Carrier input level range: | 0.02 mW to 20 Watts continuous | ||||
| c. Resolution: | |||||
| c.1 | 0.1 dB | ||||
| c.2 | 0.1W | ||||
| d. Accuracy: | +/- 10% | ||||
| e. Measurement display values: | Watts and dBm | ||||
| f. Power measurement: | Absolute and Relative | ||||
| g. Measurement type: | Average and Peak | ||||
| h. Input VSWR: | 1.4 or better |
3.4.8 RF Spectrum Analyzer. The Test Set shall provide an RF spectrum analyzer function with the following specifications:
| a. RF Range: | 1.5 MHz to 6000 MHz | |||
| b. Frequency span RF range: | 1 kHz/Div to full span | |||
| c. RF span accuracy: | +/- 5% span width | |||
| d. Input level vertical range: | Logarithmic, 10 dB/Div to 2 dB/Div | |||
| e. Input vertical resolution: | 1 dB (10 dB/Div) to 0.2 dB (2 dB/Div) | |||
| f. Display range: | 100 dB | |||
| g. Overall accuracy: | +/- 3 dB | |||
| h. Input Impedance: | 50 ohms | |||
| i. Spur-free dynamic range: | 60 dB | |||
| j. Resolution bandwidth: | < = 100 Hz to > = 1 MHz | |||
| k. Video bandwidth: | < = 300 Hz to > = 3 MHz | |||
| l. Marker functions: | ||||
| l.1 | peak | |||
| l.2 | delta | |||
| m. Input signal level: | -100 dBm to +20 dBm |
3.4.9 Audio Frequency Generator. The Test Set shall provide for an Audio Frequency (AF) generator with the following specifications:
| a. Frequency range: | 20 Hz to 20 kHz | |||
| b. Frequency resolution: | 1 Hz | |||
| c. Frequency accuracy: | +/- 0.1% | |||
| d. Output level: | 1 mV to 1 Vrms into 600 Ohms | |||
| e. Accuracy: | 5.0% with 1 kHz sinewave | |||
| f. Total harmonic distortion: | < = 1.0 % | |||
| g. Waveforms: | ||||
| g.1 | Sine | |||
| g.2 | Square | |||
| h. Ports | Two BNC, switchable I/O or each port dedicated as |
either input or output.
3.4.10 Distortion Meter. The Test Set shall provide a total harmonic distortion meter (THD and THD + Noise) with the following specifications:
| a. Range: | 0.1% to 50.0% | |
| b. Accuracy: | 10% of reading | |
| c. Resolution: | 0.1% | |
| d. Signal input freq: | 100 Hz to 10 kHz | |
| e. Input signal level: | 0.15 Vrms to 5 Vrms. |
3.4.11 SINAD Meter. The Test Set shall provide a SINAD meter with the following specifications:
| a. Range: | 0 dB to 40 dB | ||
| b. Accuracy: | 10% of reading | ||
| c. Resolution: | 1 dB | ||
| d. Input frequency range: | 100 Hz to 10 kHz | ||
| e. Input signal level: | 0.15 Vrms to 5 Vrms |
3.5 DISTANCE TO FAULT METER.
| a. Test range: | User defined from 3 ft (1 m) to 328 ft (100 m) | |||
| b. Display format: | A graphical display of Return Loss/SWR (dB, vertical) vs. DTF (ft, horizontal) | |||
| c. Horizontal display scale: | 10 divisions marked with the following: | |||
| c.1 | start | |||
| c.2 | center | |||
| c.3 | end | |||
| d. Resolution: | 320 points | |||
| e. Accuracy: | ± 3 ft | |||
| f. Vertical display scale: | 10 divisions |
3.6 SWR METER
| a. Test range: | 1 through 7 | ||
| b. Display format: | A graphical display of SWR (vertical) vs frequency (Mhz, horizontal) | ||
| c. Horizontal display scale: | 10 divisions marked with the frequency | ||
| d. Resolution: | 0.1 | ||
| e. Accuracy: | 20% of reading | ||
| f. Vertical display scale: | 10 divisions |
3.7 TIMEBASE (REFERENCE OSCILLATOR)
| a. Stability | +- .2 ppm between 0°C to 50°C |
| b. Aging | .1 ppm per year |
| c. Warm up | 15 minutes |
3.8 INTERFACES. The Test Set shall provide the following interfaces:
| a. Ethernet | RJ-45 100/10 Mbit/s (10/100 Base-T) | ||
| b USB | Type A version 3.0 interface compatible to 2.0 | ||
| c. Antenna: | TNC or N-Type, input | ||
| d. T/R | N-type, I/O | ||
| e. SWR | TNC or N-type | ||
| f. Audio x 2 | BNC | ||
| g. RS-232 serial port: | 9-Pin, D-sub Male Fully Populated |
Baud Rates 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200).
3.9 SCRIPT DEVELOPMENT AND EXECUTION:
The Test Set shall allow the user to run scripts or programs, with vendor provided commands, that are capable of the following: able to set and query the state of all meters, generators, instruments, and signal switching for the purpose of automating radio testing functions of the Test Set.
a. The Test Set architecture shall allow for non-privileged user script development.
b. The scripts shall be transferable from one Test Set to another through a provided interface.
3.10 OPERATING SYSTEM: The Operating System shall be approved by the government. If the Test Set uses a Windows Operating System, it shall be a minimum of Windows 10 and shall contain a minimum of Trusted Platform Module (TPM) Version 2.0.
3.11 ENVIRONMENTAL REQUIREMENTS: The Test Set shall conform to the Class 2 Environmental Requirements specified in Table 2 of MIL-PRF-28800F, with the following caveats included:
3.11.1 Operating Temperature: -10°C to +40° C at non-condensing RH up to 95%
3.11.2 Non-operating Temperature: -40°C to +71°C at non-condensing RH up to 80% without battery. -20°C to 60°C at non-condensing RH up to 80% with battery.
3.11.3 Bounce, Loose Cargo. The Test Set shall meet the Class 2 requirements of the Bounce, Loose Cargo test specified in sections 3.8.4.3 and 4.5.5.3.3 of MIL-PRF-28800F. The test shall be conducted on the hard transit case with all other components secured inside.
3.11.4 Shock, Functional: The Test Set shall meet all requirements of the Shock, Functional test specified in sections 3.8.5.1 and 4.5.5.4.1 of MIL-PRF-28800F.
3.11.5 Transit Drop: The Test Set shall meet the Class 2 requirements of the Transit Drop tet specified in sections 3.8.5.2 and 4.5.5.4.2. The test shall be conducted on the hard transit case with all other components secured inside.
3.11.6 Drip proof: The Test Set shall meet the Class 2 requirements of the Drip proof test specified in sections 3.8.6.3 and 4.5.5.5.3. The test shall be conducted on the Test Set while outside of the Hard and Soft Transit Cases.
3.11.7 EMC: The Test Set shall meet the requirements specified in section 4.5.6.5 and Table 6 of MIL-PRF-28800F. The Test Set shall meet Class A performance in section 9 of IEC 6100.
3.12 GENERAL REQUIREMENTS
3.12.1 Standalone. The Test Set shall be a single standalone system and shall not be dependent on external test equipment.
3.12.2 Internal DC Battery: Internal rechargeable batteries and a charger shall be provided. The batteries shall be installed in an externally accessible compartment as specified in MIL-PRF-28800F.
3.12.3 Battery operation: Minimum operating time shall be 2 hours on a full charge. The Test Set shall be operational while being charged.
3.12.4 Charger: The charger shall operate from the 50 Hz and 60 Hz alternate power source as specified in MIL-PRF-28800F, and additionally, from an external [24 VDC to 28 VDC] power source. A DC cable with NATO slave plug shall be provided to connect to a vehicle’s 24 to 28 VDC NATO slave connector.
3.12.5 Battery Status Indicator: A battery life indicator shall be incorporated into the test set.
3.12.6 Accessories: All accessories shall be stored in a protective case.
3.12.6.1 Qty 1 Attenuator, N-Male to N-Female 20 dB, 50W
3.12.6.2 Qty 1 Attenuator, N-Male to N-Female 20 dB, 200W
3.12.6.3 Qty 1 Adapter, N-Female to N-Male, 50 Ohm
3.12.6.4 Qty 2 Adapter, N-Female to BNC Female, 50 Ohm
3.12.6.5 Qty 2 Adapter, N-Male to BNC Female, 50 Ohm
3.12.6.6 Qty 2 Adapter, N-Female to BNC Male, 50 Ohm
3.12.6.7 Qty 1 Adapter, N-Female to N-Female Barrel, 50 Ohm
3.12.6.8 Qty 3 Adapter, TNC-Male to BNC Female, 50 Ohm
3.12.6.9 Qty 5 Cable, RF, BNC-M to BNC-M, 48 Inches, RG-223
3.12.6.10 Qty 1 Handset, H-250
3.12.7 Dimensions: The Test Set shall have a dimension of less than 25.5 cm x 31.75 cm x 12.7 cm (10 in x 12.5 in x 5 in).
3.12.8 Weight: The Test Set shall have a weight of no greater than 4.9 kg (11 lbs.), without batteries or accessories.
3.12.9 Stand: The Test Set shall have a stand that is either permanently or temporarily attached for the purpose of holding the test set at a 65 degree to 75 degree angle.
3.12.10 Soft Carrying Case: A soft carrying case according to MIL-PRF- 28800F shall be provided for carrying the Test Set in the operational environment. The soft carrying case shall be capable of accommodating the Test Set, accessories, and the operator’s manual.
3.12.11 Hard Transit Case: A protective hard transit case according to MIL-PRF-28800F for transporting the Test Set shall be provided. The transit case shall be capable of accommodating the Test Set, accessories, and the operator’s manual.
3.12.12 Screenshot. A screenshot capture and save function shall be provided.
3.12.13 Human Readable Identification Labeling:
3.12.13.1 Equipment: Per MIL-PRF-28800F, a human readable label shall be provided for all production lot units conforming with MIL-STD-130N and permanently affixed on the equipment in an easily readable location. Required fields on the label are; CAGE, part number, and serial number. Size of the label shall conform to the size of the equipment.
3.12.13.2 Case: Per MIL-PRF-28800F, a human readable metal plate shall be provided for all production lot units conforming with MIL-STD-130N and permanently affixed to the front of the transit case. Required fields on the label are; CAGE, part number, and serial number. Size of the label shall conform to the size of the case. Pressure sensitive adhesive transfer tape is required to hold the plate to the hard transit case such as 3M™ 9472LE. Soft transit cases also require labeling with permanent placement such as a metal plate affixed with rivets, screws or adhesives.
3.12.14 Built-in Test. The Test Set shall have a Built-in test that evaluates the general function of the test set and the functionality of its meters, generators, instruments and switches.
3.12.15 Ease of Use. The Test Set shall be capable of completing all procedures in Appendix A in 30 minutes or less.
3.12.16 Reliability. Mean-time-between-failure (MTBF) of the HHRTS shall be greater than 1,500 operating hours.