Heart O the Hills RBM report 11.25.19.pdf
PDF 5 MB Posted
- Solicitation number
- 69056720B000027
About this file
This document summarizes the results of a regulated building materials assessment conducted at the Heart O the Hills Ranger Station located in Olympic National Park in Port Angeles, Washington. The assessment was performed to identify asbestos-containing materials, lead-based paint, PCB-containing light ballasts, and mercury-containing components prior to building demolition. Twenty samples were collected and analyzed for asbestos using polarized light microscopy. None of the samples contained greater than one percent asbestos. Four paint chip samples were collected and analyzed for lead content. Three samples contained detectable levels of lead between 1,300 and 5,400 parts per million. Mercury-containing fluorescent light tubes and high-intensity discharge lamps were also identified. The associated federal contracting opportunity is for solicitation number 69056720B000027 from the Department of Transportation Federal Highway Administration concerning improvements to the Heart O the Hills Entrance Station.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| BidSum Heart O the Hills.pdf | ||
| Bid opening sign-in sheet.pdf | ||
| IFB Heart O hills.pdf | ||
| Heart O the Hills plans.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Regulated Building Materials
Assessment Report Heart O the Hills Ranger Station
Olympic National Park, 48.037624,-123.430192
Port Angeles, Washington
November 25, 2019
Terracon Project No. 81197566
Prepared for:
Jacobs Engineering.
Bellevue, Washington
Prepared by:
Terracon Consultants, Inc.
Mountlake Terrace, Washington
Project Title: Regulated Building Materials Assessment
Heart O The Hills Ranger Station
Olympic National Park, 48.037624,-123.430192
Port Angeles, Washington
Prepared for: Mr. Michael Wirtz
Jacobs Engineering Group
600 108th Avenue NE
Bellevue, Washington 98004
Assessment Conducted by: Terracon Consultants
1900 W. Nickerson Street, Suite 315
Seattle, Washington 98119
Terracon Project Number: 81197566
Assessment Personnel: Mr. Jacob Iverson
AHERA-Accredited Building Inspector
Number 172933 (exp. 4/26/2020)
Assessment Date: November 5, 2019
Report Prepared by:
Jacob Iverson
Field Scientist
Terracon Consultants
Report Reviewed by:
Scott Parker
Department Manager
Terracon Consultants
Report Issue Date: November 25, 2019
Regulated Building Materials Assessment Heart O The Hills Ranger Station November 25, 2019 Jacobs Engineering Group Terracon #81197566
TABLE OF CONTENTS
EXECUTIVE SUMMARY ....................................................................................... i
1.0 INTRODUCTION
2.0 PROJECT BACKGROUND
2.1 Sources of Information
2.2 Building Description
3.0 ASBESTOS ASSESSMENT
3.1 Building Assessment
3.2 Sampling Procedures
3.3 Analytical Methodology
3.4 Asbestos Results
4.0 LEAD ASSESSMENT
4.1 Sampling Methodology
4.2 Lead Sampling Results
5.0 OTHER REGULATED BUILDING MATERIALS
5.1 Methodology – Universal Wastes
5.2 Results
6.0 CONCLUSIONS AND RECOMMENDATIONS
6.1 Asbestos
6.2 Lead
6.3 Other Regulated Building Materials
7.0 LIMITATIONS
Figure Photographs
Appendices Appendix A. Asbestos Laboratory Analytical Results Appendix B. Lead Laboratory Analytical Results Appendix C. Certifications and Accreditations
Jacobs Engineering Group Terracon #81197566
Page i
EXECUTIVE SUMMARY
Jacobs Engineering Group retained Terracon Consultants (Terracon) to conduct a regulated building materials assessment of the Heart O The Hills Ranger Station, located at Olympic National Park, 48.037624,-123.430192 in Port Angeles, Washington.
Terracon’s representative, Mr. Jacob Iverson, conducted the assessment on November
5, 2019. The scope of the services provided is described in Terracon Proposal Number
P81197566 dated October 10, 2019.
Terracon assessed the building for the following regulated building materials:
• Asbestos-containing materials (ACM);
• Assumed asbestos-containing materials;
• Lead-containing coatings (paints);
• Mercury-containing light tubes, switches, and thermostats;
• Suspected high-intensity discharge (HID) lamps; and
• Suspected PCB-containing fluorescent light ballasts.
Twenty bulk samples of suspect asbestos-containing materials were collected and analyzed using Polarized Light Microscopy (PLM). None of the materials were found to contain greater than one percent asbestos and none of the materials were assumed to contain asbestos. In addition, four materials were visually assessed and determined to be non-suspect.
Four paint chip samples were collected and analyzed for total lead content. Three of the paint chip samples were found to contain detectable levels of lead.
Mercury-containing fluorescent light tubes were identified in the building. HID lamps were identified on the exterior of the building. Light ballasts associated with fluorescent light fixtures were assumed to be PCB-containing.
Jacobs Engineering Group Terracon #81197566
1.0 INTRODUCTION
Jacobs Engineering Group retained Terracon Consultants (Terracon) to conduct a regulated building materials assessment of the Heart O The Hills Ranger Station, located at Olympic National Park, 48.037624,-123.430192 in Port Angeles, Washington.
Terracon’s representative, Mr. Jacob Iverson, conducted the assessment on November
5, 2019. The scope of the services provided is described in Terracon Proposal Number
P81197566 dated October 10, 2019.
Terracon assessed the building for the following regulated building materials:
• Asbestos-containing materials (ACM);
• Assumed asbestos-containing materials;
• Lead-containing coatings (paints);
• Mercury-containing light tubes, switches, and thermostats;
• Suspected high-intensity discharge (HID) lamps; and
• Suspected PCB-containing fluorescent light ballasts.
2.0 PROJECT BACKGROUND
This report presents the results of our regulated building materials assessment of the
Heart O The Hills Ranger Station located at Olympic National Park, 48.037624,-
123.430192 in Port Angeles, Washington. The purpose of the assessment was to identify potential asbestos-containing material, lead-containing coatings, PCB-containing light ballasts, and mercury-containing components prior to building demolition and for purposes of hazard communication and on-going management. The assessment included the interior, exterior, and roof.
This assessment will assist Jacobs Engineering Group with communicating the presence of regulated building materials, and the presence, location, and quantity of ACM to employees, vendors, and contractors working in the project area and to meet the requirements for an asbestos survey for the Olympic Region Clean Air Agency (ORCAA) and a good faith inspection as required by Washington State Department of Labor and
Industries’ Division of Occupational Safety and Health (DOSH) regulations prior to building demolition. Regulations require that a complete copy of this assessment be kept in a conspicuous location on-site at all times during activities that may impact known and suspect ACM.
2.1 Sources of Information
During the course of the assessment, the following individuals and drawings provided assistance to the Terracon inspector:
Jacobs Engineering Group Terracon #81197566
• Mr. Michael Wirtz, Jacobs Engineering Group
• Mr. Brad Metler, National Parks Service
2.2 Building Description
The Heart O The Hills Ranger Station is located at Olympic National Park, 48.037624,-
123.430192 in Port Angeles, Washington. The building was constructed at an unknown date and contains approximately 500 square feet of interior floor space. The building consists of two sections with a drive through area in the middle. The building consists of an office, a bathroom, and a storage closet.
The building is wood construction that sits on a concrete foundation. The roof consists of wood shingles above an asphaltic vapor barrier. The building is heated by a forced air heating, ventilating, and air conditioning (HVAC) system. Interior floors consist of concrete, vinyl floor sheeting on concrete, and wood decking. Interior walls and ceilings consist of wood.
The observed piping was not insulated. The observed HVAC ducting is insulated with foil-wrapped fiberglass.
3.0 ASBESTOS ASSESSMENT
3.1 Building Assessment
Mr. Iverson, an Asbestos Hazard Emergency Response Act (AHERA)-accredited building inspector (Certification 172933, expiration date: 4/26/2020) from Terracon, performed the sampling on November 5, 2019. Terracon’s inspector collected twenty samples of materials identified as suspect ACM.
This assessment was conducted using a modified protocol adapted from AHERA. The protocol is as follows:
• Identify suspect asbestos-containing materials.
• Group materials into homogeneous sampling areas/materials.
• Quantify each homogeneous material and collect representative samples. The number of samples collected of miscellaneous materials was determined by the inspector.
• Samples of each material were taken to the substrate, ensuring that all components and layers of the material were included.
• Sample locations are referenced on the field data forms according to sample number.
Jacobs Engineering Group Terracon #81197566
• Sampling was performed by an AHERA-accredited building inspector, and the use of proper protective equipment and procedures was followed.
3.2 Sampling Procedures
This sampling was conducted using the following procedures:
1. Spread the plastic drop cloth (if needed) and set up other equipment, e.g., ladder.
2. Don protective equipment (respirator and protective clothing if needed).
3. Label sample container with its identification number and record number. Record sample location and type of material sampled on a sampling data form.
4. Moisten area where sample is to be extracted (spray the immediate area with water).
5. Extract sample using a clean knife, drill capsule, or cork boring tool to cut out or scrape off approximately one tablespoon of the material. Penetrate all layers of material.
6. Place sample in a container and tightly seal it.
7. Wipe the exterior of the container with a wet wipe to remove any material that may have adhered to it during sampling.
8. Clean tools with wet wipes and wet mop; or vacuum area with HEPA vacuum to clean all debris.
9. Discard protective clothing, wet wipes and rags, cartridge filters, and drop cloth in a labeled plastic waste bag.
3.3 Analytical Methodology
Suspect ACMs were sampled in general accordance with 40 CFR 763.86 by an
Environmental Protection Agency (EPA) AHERA-accredited building inspector. Each sample was collected and stored in a heavy-duty, self-sealing plastic bag, and delivered to NVL Laboratories in Mountlake Terrace, Washington. Samples were analyzed via polarized light microscopy (PLM) in accordance with EPA/600/R-93/116. NVL
Laboratories is accredited to perform PLM analysis by the National Institute of Standards and Technology National Voluntary Laboratory Accreditation Program (NVLAP).
3.4 Asbestos Results
Table 3.4-1 provides a list of suspect homogeneous sampling area (HSA) material descriptions, material locations, and results for this sampling. Refer to the attached
Figures for sample locations and room number designations (as applicable). Refer to the attached photographs for HSA pictures.
Jacobs Engineering Group Terracon #81197566
Table 3.4-1. Results of Bulk Sample Analyses
HSA ID, Material Description, and AHERA Classification
Material Location HSA Results
1: Plywood boards (M) Walls and ceilings throughout Visually assessed and determined to be non-suspect
2: Brown paper with black mastic and pink fiberglass insulation (T)
Above ceilings and in some walls throughout
Paper backing with mastic: ND Pink fiberglass: ND
3: Black asphaltic vapor barrier (M)
Below wood shingles throughout roof ND
4: Grey tape sealant(M) On HVAC system in places ND
5: Grey caulking (M) Associated with/around exterior windows
ND
6: Grey sealant/mudding and black mastic (M)
Associated with some pipes at ground level
Sealant: ND Mastic: ND
7: Beige spackled vinyl floor sheeting and grey paper backing with mastic (M)
East section, north side on floor above wood decking
Vinyl: ND Paper backing with mastic: ND
8: Grey vinyl floor sheeting and off-white paper backing with mastic (M)
East section, south side on floor in places (Residual)
Vinyl: ND Paper backing with mastic: ND
9: White coated polypropylene vapor barrier (M)
East side structure in walls throughout
Visually assessed and determined to be non-suspect
10: Black asphaltic vapor barrier (M)
West side structure in walls throughout
ND
11: Foil-wrapped yellow fiberglass insulation (T)
In attic area of east structure Visually assessed and determined to be non-suspect
12: Plastic backed fiberglass insulation (T)
In places in attic throughout Visually assessed and determined to be non-suspect
Jacobs Engineering Group Terracon #81197566
If the analytical results indicate that all the samples collected per HSA do not contain asbestos, then the HSA (material) is considered a non-ACM. However, if the analytical results of one or more of the samples collected per HSA indicate that asbestos is present in quantities of greater than one percent asbestos as defined by the EPA, all of the HSA
(material) is considered to be an ACM regardless of any other analytical results (unless a representative number of samples have been analyzed by PLM point counting as described below, and the results indicate the material contains less than one percent asbestos).
Any material that contains greater than one percent asbestos is considered an ACM and must be handled according to Occupational Safety and Health Administration (OSHA), EPA, and applicable state and local regulations. The EPA National Emission Standard for
Hazardous Air Pollutants (NESHAP) 40 CFR 61, Subparts A and M has a requirement related to assessment of suspect ACM in buildings. When the asbestos content of a friable material is visually estimated by PLM to be detectable but less than ten percent, your firm may elect to (1) assume the amount is greater than one percent and treat the material as asbestos-containing or (2) require verification of the amount by the PLM point counting technique. If the results obtained by point counting and visual estimation are different, the point count result must be used. When no asbestos is detected by PLM, point counting is not required.
4.0 LEAD ASSESSMENT
Homogeneous areas of suspected lead-containing coatings (paints) were identified and sampled in accessible areas throughout the Heart O The Hills Ranger Station located at
Olympic National Park, 48.037624,-123.430192 in Port Angeles, Washington.
Homogeneous painted surfaces were defined by substrate, application, and color.
4.1 Sampling Methodology
Paint chip samples were collected to the substrate to ensure that all layers present on the substrate were included in the laboratory analysis. Each sample was collected and stored in a heavy-duty, self-sealing plastic bag and delivered to NVL Laboratories in Seattle, Washington. Samples were analyzed via Atomic Absorption Spectrophotometry in accordance with Method EPA 7000B. NVL Laboratories in Seattle, Washington is accredited by the American Industrial Hygiene Association (AIHA) for lead analysis.
4.2 Lead Sampling Results
Four paint chip samples were collected and analyzed for lead. Three samples had reportable levels of lead. The results of the analyses are presented in Table 4.2-1.
Jacobs Engineering Group Terracon #81197566
Table 4.2-1. Paint Chip Sample Results
Paint Number and Description Paint Location Sample Result in parts per million (ppm)
Pb1: Blue paint on wood Interior walls, predominant 3,000
Pb2: Beige on wood Exterior siding 5,400
Pb3: Tan on wood Exterior wood trim, door frame 1,300
Pb4: White on wood Interior ceiling throughout <53
<: below the reporting limit
5.0 OTHER REGULATED BUILDING MATERIALS
5.1 Methodology – Universal Wastes
An inventory of fluorescent light tubes, HID lamps, and potential PCB-containing ballasts was conducted in accessible areas of the project.
Where fluorescent light fixtures were accessible, the ballast covers were removed, and the ballast labels were visually examined. Different types of fluorescent fixtures were distinguished by shield shape, fixture dimension, diffuser type, and the manner in which the ballast covers were connected to the fixture.
Where fluorescent light fixtures could not be visually examined, the number of potential
PCB-containing ballasts in fixtures was estimated based on the following assumptions:
• Each multiple light tube fluorescent fixture contains one ballast for every pair of light tubes.
• All light ballasts are assumed to contain PCBs unless the manufacturer’s label indicates they are electronic ballasts.
Where high intensity discharge lamps could not be accessed or examined, the following assumptions were made:
• Each HID lamp contains one ballast;
• Each HID lamp contains a minimum of one mercury bulb, sodium vapor bulb, or metal halide bulb.
Jacobs Engineering Group Terracon #81197566
5.2 Results
Fluorescent light tubes were observed throughout the building interior. HID lamps are present on the building exterior. Light ballasts associated with fluorescent light fixtures were assumed to be PCB-containing. Fluorescent light tubes, PCB ballasts, and HID lamps were identified in the following quantities:
Table 5.2-1. Universal Wastes Results
Other Regulated Building Materials Description Approximate Quantity
Mercury-containing fluorescent light tubes (4’ length) 9
PCB-containing light ballasts (assumed) 3
HID lights 3
6.0 CONCLUSIONS AND RECOMMENDATIONS
On November 5, 2019, Terracon conducted a regulated building materials assessment of the Heart O The Hills Ranger Station located at Olympic National Park, 48.037624,-
123.430192 in Port Angeles, Washington.
6.1 Asbestos
No asbestos was detected in the materials sampled.
Additional suspect ACMs may be present in areas not assessed or that were inaccessible or concealed. These spaces include, but are not limited to, below wood decking, electrical systems, pipe chases, spaces between wall/ceiling/door/floor cavities, interior of mechanical components, beneath foundation pads, etc. If future maintenance, renovation, and/or demolition activities make these areas accessible, Terracon recommends that a thorough assessment of these spaces be conducted at that time to identify and confirm the presence or absence of additional suspect ACMs. Until then, all such unidentified materials must be treated as assumed ACMs in accordance with applicable federal, state, and local regulations.
6.2 Lead
Three paints sampled and analyzed contained detectable levels of lead.
The Washington State Department of Labor and Industries requires an exposure assessment be conducted during operations that may disturb the lead paint in such a way that the airborne exposure may reach or exceed the Action level of 30 micrograms per cubic meter (µg/m3) or the Permissible Exposure Limit of 50 µg/m3. The worker protection requirements of WAC 296-155-176 "Lead in Construction" may apply.
Jacobs Engineering Group Terracon #81197566
Some of the coatings contained detectable levels of lead. If this building or portions of it will be demolished and disposed of, a toxicity characteristic leachate procedure (TCLP) sample that is representative of the waste stream must be collected and analyzed per the requirements of WAC 173-303. If the results of the TCLP analysis determine the waste to be a "dangerous waste" as defined by WAC 173-303, it must be disposed of accordingly.
The lead paint chip sampling and reporting conducted as a part of this assessment may not be used to meet the requirements of the Environmental Protection Agency’s Lead;
Renovation, Repair, and Painting rule (RRP). Refer to 40CFR745 for additional information.
6.3 Other Regulated Building Materials
Fluorescent light tubes, HID lamps, switches, and thermostats may contain mercury.
Fluorescent light ballasts and HID lamp ballasts may contain PCBs. In Washington State, even ballasts labeled with "No PCBs" may have regulated amount of PCBs and therefore should be handled in accordance with Washington Department of Ecology requirements.
Employers must inform their employees of mercury and PCB hazards in accordance with
WAC 296-800-170.
Fluorescent light tubes, HID lamps, switches, and thermostats light ballasts must be removed and recycled or disposed of prior to building demolition as per 40 CFR 262, 40
CFR 265, and WAC 173-303.
7.0 LIMITATIONS
This report presents the results of the regulated building materials assessment conducted at the Heart O The Hills Ranger Station located at Olympic National Park, 48.037624,-
123.430192 in Port Angeles, Washington. The assessment was for the purposes of identifying ACM, lead-containing paint, mercury-containing components, PCB ballasts, and HID lamps prior to demolition.
Jacobs Engineering Group Terracon #81197566
Regulated building material assessments are non-comprehensive and subject to many limitations, including those presented below. Our assessment has considered risks pertaining to asbestos, lead in coatings, fluorescent lamps, mercury switches, PCB ballasts, and HID lamps; however, this assessment is limited to only those locations and materials assessed. This assessment was not designed to identify all potential concerns or to eliminate all risks associated with renovation, demolition, material removal, construction, or transferring of property title. Evaluation of other risks not specifically described in the Scope of Work have not been included; for example: structural integrity;
engineering loads; electrical; mechanical; radon gas; slope stability; building settlement;
and evaluation of toxic and hazardous substances in, or in contact with, soil and groundwater. No warranty, expressed or implied, is made.
Terracon has performed the services set forth in the Scope of Work in accordance with generally accepted industrial hygiene practices in the same or similar localities, related to the nature of the work accomplished, at the time the services were performed.
The regulated building materials and conditions presented in this report represent those observed on the dates we conducted the sampling. This sampling is intended for the exclusive use of Jacobs Engineering Group for specific application to the referenced property. This assessment does not replace nor can be used as professionally developed construction or demolition plans, specifications, or bidding documents. This report is not a legal opinion.
Prepared by: Reviewed by:
Jacob Iverson Scott Parker Field Scientist Department Manager Terracon Consultants Terracon Consultants
Jacobs Engineering Group Terracon #81197566
Figure
Figure 1 Jacobs Engineering Group
Bulk Sample Locations
TERRACON • 21905 64TH AVE W. • SUITE 100 • MOUNTLAKE TERRACE, WA 98043 • 425.771.3304 • TERRACON.COM
NOT TO SCALE
NOTE: Sample numbers on this drawing are abbreviated.
For complete sample numbers, see laboratory analytical results.
Jacobs Engineering Group Terracon #81197566
Photographs
Olympic National Park, 48.037624,-123.430192 November 25, 2019 Jacobs Engineering Group Terracon Consultants, Inc. #81197566
HSA No. 1. Plywood boards (M)
HSA No. 2. Brown paper with black mastic and pink fiberglass insulation (T)
HSA No. 3. Black asphaltic vapor barrier (M)
HSA No. 4. Grey tape sealant(M)
HSA No. 5. Grey caulking (M)
HSA No. 6. Grey sealant/mudding and black mastic (M)
HSA No. 7. Beige spackled vinyl floor sheeting and grey paper backing with mastic (M)
HSA No. 8. Grey vinyl floor sheeting and off-white paper backing with mastic (M)
HSA No. 9. White coated polypropylene vapor barrier (M)
HSA No. 10. Black asphaltic vapor barrier (M)
HSA No. 11. Foil-wrapped yellow fiberglass insulation (T)
HSA No. 12. Plastic backed fiberglass insulation (T)
Jacobs Engineering Group Terracon #81197566
Appendix A Asbestos Laboratory Analytical Results
Matt Macfarlane, Asbestos Lab Supervisor
Client Project: 81197566 Location: Heart O' The Hills
Dear Ms. Anderson, Enclosed please find test results for the 20 sample(s) submitted to our laboratory for analysis on 11/6/2019.
Examination of these samples was conducted for the presence of identifiable asbestos fibers using polarized light microscopy (PLM) with dispersion staining in accordance with both EPA 600/M4-82-020, Interim Method for the Determination of Asbestos in Bulk Insulation Samples and EPA 600/R-93/116 Method for the Determination of Asbestos in Bulk Building Materials.
For samples containing more than one separable layer of materials, the report will include findings for each layer (labeled Layer 1 and Layer 2, etc. for each individual layer). The asbestos concentration in the sample is determined by calibrated visual estimation.
For those samples with asbestos concentrations between 1 and 10 percent based on visual estimation, the EPA recommends a procedure known as point counting (NESHAPS, 40 CFR Part 61). Point counting is a statistically more accurate means of quantification for samples with low concentrations of asbestos.
The detection limit for the calibrated visual estimation is <1%, 400 point counts is 0.25% and 1000 point counts is 0.1%
Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.
Thank you for using our laboratory services. Please do not hesitate to call if there is anything further we can assist you with.
Sincerely, Enc.: Sample Results
November 12, 2019
Christina Anderson ARGUS PACIFIC, INC. A Terracon Company 21905 64th Avenue W, Suite 100 Mountlake Terrace, WA 98043
RE: Bulk Asbestos Fiber Analysis; NVL Batch # 1923640.00
< Client:
Address:
Attention: Ms. Christina Anderson Heart O' The Hills
Client Project #: 81197566
Samples Received: 20
By Polarized Light Microscopy Bulk Asbestos Fibers Analysis
ARGUS PACIFIC, INC. A Terracon Company 21905 64th Avenue W, Suite 100 Mountlake Terrace, WA 98043
Method: EPA/600/R-93/116
& EPA/600/M4-82-020
Samples Analyzed: 20 Project Location:
Batch #: 1923640.00
Date Received: 11/6/2019
19129434Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-2-01
Layer 1 of 1 Description: Brown fibrous material with thin black asphaltic mastic Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Asphalt/Binder, Fine particles 61%Cellulose None Detected ND
Glass debris
19129435Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-2-02
Layer 1 of 2 Description: Brown fibrous material with thin black asphaltic mastic Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Asphalt/Binder, Fine particles 63%Cellulose None Detected ND Layer 2 of 2 Description: Thin pale pink fibrous material
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % Binder/Filler, Glass debris 93%Glass fibers None Detected ND
19129436Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-2-03
Layer 1 of 2 Description: Brown fibrous material with thin black asphaltic mastic Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Asphalt/Binder, Fine particles 64%Cellulose None Detected ND Layer 2 of 2 Description: Thin pale pink fibrous material
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % Binder/Filler, Glass debris 96%Glass fibers None Detected ND
19129437Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-3-01
Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA 600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government
Client Hilary CrumleyAnalyzed by:
Matt MacfarlaneReviewed by:
11/12/2019 Date:
11/12/2019Date:
Sampled by:
Matt Macfarlane, Asbestos Lab Supervisor
ASB-02
Attention: Ms. Christina Anderson Heart O' The Hills
Client Project #: 81197566
Samples Received: 20
By Polarized Light Microscopy Bulk Asbestos Fibers Analysis
ARGUS PACIFIC, INC. A Terracon Company 21905 64th Avenue W, Suite 100 Mountlake Terrace, WA 98043
Method: EPA/600/R-93/116
& EPA/600/M4-82-020
Samples Analyzed: 20 Project Location:
Batch #: 1923640.00
Date Received: 11/6/2019
Layer 1 of 1 Description: Black asphaltic fibrous material with black asphaltic soft mastic with plastic Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Asphalt/Binder, Fine particles, Plastic 53%Cellulose None Detected ND
19129438Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-3-02
Layer 1 of 1 Description: Black asphaltic soft mastic with plastic Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Asphalt/Binder, Fine particles, Plastic NDNone Detected None Detected ND
19129439Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-3-03
Layer 1 of 1 Description: Black asphaltic soft mastic with plastic and debris Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Asphalt/Binder, Fine particles, Plastic <1%Cellulose None Detected ND
Debris
19129440Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-4-01
Layer 1 of 1 Description: White woven fibrous material with yellow mastic and gray coating Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Mastic/Binder, Fine particles 49%Cellulose None Detected ND
13%Synthetic fibers
19129441Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-4-02
Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA 600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government
Client Hilary CrumleyAnalyzed by:
Matt MacfarlaneReviewed by:
11/12/2019 Date:
11/12/2019Date:
Sampled by:
Matt Macfarlane, Asbestos Lab Supervisor
Attention: Ms. Christina Anderson Heart O' The Hills
Client Project #: 81197566
Samples Received: 20
By Polarized Light Microscopy Bulk Asbestos Fibers Analysis
ARGUS PACIFIC, INC. A Terracon Company 21905 64th Avenue W, Suite 100 Mountlake Terrace, WA 98043
Method: EPA/600/R-93/116
& EPA/600/M4-82-020
Samples Analyzed: 20 Project Location:
Batch #: 1923640.00
Date Received: 11/6/2019
Layer 1 of 1 Description: White woven fibrous material with yellow mastic and gray coating Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Mastic/Binder, Fine particles 51%Cellulose None Detected ND
12%Synthetic fibers
19129442Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-5-01
Layer 1 of 1 Description: Gray soft material with paint and wood debris Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Fine particles, Wood flakes 4%Polyethylene fibers None Detected ND
3%Cellulose
19129443Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-5-02
Layer 1 of 1 Description: Gray soft material with paint and wood debris Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Fine particles, Wood flakes 5%Polyethylene fibers None Detected ND
Debris 2%Cellulose
19129444Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-5-03
Layer 1 of 1 Description: Gray soft material with paint and wood debris Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Fine particles, Wood flakes 4%Polyethylene fibers None Detected ND
Debris 4%Cellulose
Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA 600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government
Client Hilary CrumleyAnalyzed by:
Matt MacfarlaneReviewed by:
11/12/2019 Date:
11/12/2019Date:
Sampled by:
Matt Macfarlane, Asbestos Lab Supervisor
Attention: Ms. Christina Anderson Heart O' The Hills
Client Project #: 81197566
Samples Received: 20
By Polarized Light Microscopy Bulk Asbestos Fibers Analysis
ARGUS PACIFIC, INC. A Terracon Company 21905 64th Avenue W, Suite 100 Mountlake Terrace, WA 98043
Method: EPA/600/R-93/116
& EPA/600/M4-82-020
Samples Analyzed: 20 Project Location:
Batch #: 1923640.00
Date Received: 11/6/2019
19129445Lab ID: Client Sample #:
Location: Heart O' The Hills Comments: Insufficient black mastic for further analysis.
HOH-6-01
Layer 1 of 2 Description: Gray brittle material Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Fine grains, Fine particles NDNone Detected None Detected ND Layer 2 of 2 Description: Trace black asphaltic mastic
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % Asphalt/Binder, Fine particles NDNone Detected None Detected ND
19129446Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-6-02
Layer 1 of 2 Description: Gray brittle material Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Fine grains, Fine particles <1%Cellulose None Detected ND Layer 2 of 2 Description: Thin black asphaltic mastic
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % Asphalt/Binder, Fine particles NDNone Detected None Detected ND
19129447Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-7-01
Layer 1 of 2 Description: Beige sheet vinyl Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Vinyl/Binder, Synthetic foam NDNone Detected None Detected ND Layer 2 of 2 Description: Off-white fibrous backing with soft yellow mastic and wood debris
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % Binder/Filler, Mastic/Binder, Fine particles 46%Cellulose None Detected ND
Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA 600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government
Client Hilary CrumleyAnalyzed by:
Matt MacfarlaneReviewed by:
11/12/2019 Date:
11/12/2019Date:
Sampled by:
Matt Macfarlane, Asbestos Lab Supervisor
Attention: Ms. Christina Anderson Heart O' The Hills
Client Project #: 81197566
Samples Received: 20
By Polarized Light Microscopy Bulk Asbestos Fibers Analysis
ARGUS PACIFIC, INC. A Terracon Company 21905 64th Avenue W, Suite 100 Mountlake Terrace, WA 98043
Method: EPA/600/R-93/116
& EPA/600/M4-82-020
Samples Analyzed: 20 Project Location:
Batch #: 1923640.00
Date Received: 11/6/2019
Wood flakes 11%Glass fibers
19129448Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-7-02
Layer 1 of 2 Description: Brown/white soft foamy material with debris Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Synthetic foam, Debris 2%Cellulose None Detected ND Layer 2 of 2 Description: Off-white fibrous backing with brittle yellow mastic and debris
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % Binder/Filler, Mastic/Binder, Fine particles 58%Cellulose None Detected ND
Debris
19129449Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-7-03
Layer 1 of 2 Description: Beige sheet vinyl Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Vinyl/Binder, Synthetic foam NDNone Detected None Detected ND Layer 2 of 2 Description: Off-white fibrous backing with brittle yellow mastic and debris
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % Binder/Filler, Mastic/Binder, Fine particles 56%Cellulose None Detected ND
Debris
19129450Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-8-01
Layer 1 of 2 Description: Brown/white soft foamy material with debris Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Synthetic foam, Debris <1%Cellulose None Detected ND
Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA 600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government
Client Hilary CrumleyAnalyzed by:
Matt MacfarlaneReviewed by:
11/12/2019 Date:
11/12/2019Date:
Sampled by:
Matt Macfarlane, Asbestos Lab Supervisor
Attention: Ms. Christina Anderson Heart O' The Hills
Client Project #: 81197566
Samples Received: 20
By Polarized Light Microscopy Bulk Asbestos Fibers Analysis
ARGUS PACIFIC, INC. A Terracon Company 21905 64th Avenue W, Suite 100 Mountlake Terrace, WA 98043
Method: EPA/600/R-93/116
& EPA/600/M4-82-020
Samples Analyzed: 20 Project Location:
Batch #: 1923640.00
Date Received: 11/6/2019
Layer 2 of 2 Description: Off-white fibrous backing with brittle yellow mastic and debris Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Mastic/Binder, Fine particles 53%Cellulose None Detected ND
Debris
19129451Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-8-02
Layer 1 of 2 Description: Brown/white soft foamy material with debris Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Synthetic foam, Debris 2%Cellulose None Detected ND Layer 2 of 2 Description: Off-white fibrous backing with brittle yellow mastic and debris
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % Binder/Filler, Mastic/Binder, Fine particles 56%Cellulose None Detected ND
Debris
19129452Lab ID: Client Sample #:
Location: Heart O' The Hills
HOH-10-01
Layer 1 of 1 Description: Black asphaltic fibrous material Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Asphalt/Binder, Fine particles 56%Cellulose None Detected ND
19129453Lab ID: Client Sample #:
Location: Heart O' The Hills Comments: Unable to analyze silver paint as a separate layer, not enough for thorough analysis.
HOH-10-02
Layer 1 of 1 Description: Black asphaltic fibrous material with trace silver paint Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Asphalt/Binder, Fine particles, Metallic paint 56%Cellulose None Detected ND
Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA 600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government
Client Hilary CrumleyAnalyzed by:
Matt MacfarlaneReviewed by:
11/12/2019 Date:
11/12/2019Date:
Sampled by:
Matt Macfarlane, Asbestos Lab Supervisor
ARGUS PACIFIC, INC. A Terracon Company
1923640.00
Company NVL Batch Number
Total Number of Samples
Heart O' The Hills
5 DaysTAT
11/13/2019Due Date 11:15 AMTime
(206) 285-3927Fax christina@arguspacific.comEmail
Project Manager Ms. Christina Anderson
(206) 285-3373Phone
Rush Samples
Rush TAT NoAH
81197566Project Name/Number: Project Location:
Sample ID Description A/RLab ID
ASBESTOS LABORATORY SERVICES
Subcategory
Item Code
PLM Bulk
Metals ASB-02 EPA 600/R-93-116 Asbestos by PLM <bulk>
21905 64th Avenue W, Suite 100 Mountlake Terrace, WA 98043
Address
HOH-2-011 A19129434
HOH-2-022 A19129435
HOH-2-033 A19129436
HOH-3-014 A19129437
HOH-3-025 A19129438
HOH-3-036 A19129439
HOH-4-017 A19129440
HOH-4-028 A19129441
HOH-5-019 A19129442
HOH-5-0210 A19129443
HOH-5-0311 A19129444
HOH-6-0112 A19129445
HOH-6-0213 A19129446
HOH-7-0114 A19129447
HOH-7-0215 A19129448
HOH-7-0316 A19129449
HOH-8-0117 A19129450
HOH-8-0218 A19129451
Office Use Only Print Name Company Date TimeSignature
Faxed Emailed
Company Date TimeSignature ClientSampled by
Matthew McCallumReceived by
ClientRelinquished by
Hilary CrumleyAnalyzed by Results Called by
NVL
NVL
11/6/19 11/12/19
Print Name
Entered By: Michael Jenkins
Date: 11/6/2019 Time: 4:46 PM
Special Instructions:
1923640.00
Company NVL Batch Number
Total Number of Samples
Heart O' The Hills
5 DaysTAT
11/13/2019Due Date 11:15 AMTime
(206) 285-3927Fax christina@arguspacific.comEmail
Project Manager Ms. Christina Anderson
(206) 285-3373Phone
Rush Samples
Rush TAT NoAH
81197566Project Name/Number: Project Location:
Sample ID Description A/RLab ID
ASBESTOS LABORATORY SERVICES
Subcategory
Item Code
PLM Bulk
Metals ASB-02 EPA 600/R-93-116 Asbestos by PLM <bulk>
21905 64th Avenue W, Suite 100 Mountlake Terrace, WA 98043
Address
HOH-10-0119 A19129452
HOH-10-0220 A19129453
Office Use Only Print Name Company Date TimeSignature
Faxed Emailed
Company Date TimeSignature ClientSampled by
Matthew McCallumReceived by
ClientRelinquished by
Hilary CrumleyAnalyzed by Results Called by
NVL
NVL
11/6/19 11/12/19
Print Name
Entered By: Michael Jenkins
Date: 11/6/2019 Time: 4:46 PM
Special
Jacobs Engineering Group Terracon #81197566
Appendix B Lead Laboratory Analytical Results
RE: Metals Analysis; NVL Batch # 1923675.00
Dear Ms. Anderson, November 8, 2019
ARGUS PACIFIC, INC. A Terracon Company Christina Anderson
21905 64th Avenue W, Suite 100 Mountlake Terrace, WA 98043
Enclosed please find the test results for samples submitted to our laboratory for analysis.
Preparation of these samples was conducted following protocol outlined in EPA Method SW 846 -3051 unless stated otherwise. Analysis of these samples was performed using analytical instruments in accordance with U.S. EPA, NIOSH, OSHA and other ASTM methods.
For matrix materials submitted as paint, dust wipe, soil or TCLP samples, analysis for the presence of total metals is conducted using published U.S. EPA Methods. Paint and soil results are usually expressed in mg/Kg which is equivalent to parts per million (ppm). Lead (Pb) in paint is usually expressed in mg/Kg (ppm) , Percent (%) or mg/cm2 by area. Dust wipe sample results are usually expressed in ug/wipe and ug/ft2. TCLP samples are reported in mg/L (ppm). For air filter samples, analyses are conducted using NIOSH and OSHA Methods. Results are expressed in ug/filter and ug/m3. Other matrix materials are analyzed accordingly using published methods or specified by client. The reported test results pertain only to items tested and are not blank corrected.
For recent regulation updates pertaining to current regulatory levels or permissible exposure levels, please call your local regulatory agencies for more details.
This report is considered highly confidential and will not be released without your approval.
Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.
Thank you for using our laboratory services. if you need further assistance please feel free to call us at 206-547-0100 or 1-888-NVLLABS.
Sincerely, Shalini Patel, Lab Supervisor
Enc.: Sample results
Analysis Report Total Lead (Pb)
Hearts O'Hills
ARGUS PACIFIC, INC. A Terracon CompanyClient:
21905 64th Avenue W, Suite 100 Mountlake Terrace, WA 98043
Ms. Christina AndersonAttention:
Address:
Project Location: Samples Received: 4 Samples Analyzed: 4
Client Project #: 81197566
Batch #: 1923675.00
Date Received: 11/6/2019
Lab ID Client Sample # Sample Weight (g)
Results in mg/Kg
Results in percent
RL in mg/Kg
Matrix: Paint Method: EPA 3051/7000B
19129554 Pb1-01 0.1823 55 3000 0.30
19129555 Pb2-01 0.1877 53 5400 0.54
19129556 Pb3-01 0.1920 52 1300 0.13
19129557 Pb4-01 0.1898 53 < 53 0.0053<
FAA-02
ClientSampled by:
Yasuyuki HidaAnalyzed by:
Shalini PatelReviewed by:
11/07/2019Date Analyzed:
11/08/2019Date Issued:
Bench Run No: 2019-1107-13 mg/ Kg =Milligrams per kilogram RL = Reporting Limit Percent = Milligrams per kilogram / 10000 '<' = Below the reporting Limit Note : Method QC results are acceptable unless stated otherwise.
Unless otherwise indicated, the condition of all samples was acceptable at time of receipt.
Shalini Patel, Lab Supervisor
1923675.00
Company NVL Batch Number
Total Number of Samples
Hearts O'Hills
5 DaysTAT
11/13/2019Due Date 11:15 AMTime
(206) 285-3927Fax christina@arguspacific.comEmail
Project Manager Ms. Christina Anderson
(206) 285-3373Phone
Rush Samples
Rush TAT NoAH
81197566Project Name/Number: Project Location:
Sample ID Description A/RLab ID
LEAD LABORATORY SERVICES
Subcategory
Item Code
Flame AA (FAA)
Metals FAA-02 EPA 7000B Lead by FAA <paint>
21905 64th Avenue W, Suite 100 Mountlake Terrace, WA 98043
Address
Pb1-011 A19129554 Pb2-012 A19129555 Pb3-013 A19129556 Pb4-014 A19129557
Office Use Only Print Name Company Date TimeSignature
Faxed Emailed
Company Date TimeSignature ClientSampled by
Matthew McCallumReceived by
ClientRelinquished by
Yasuyuki HidaAnalyzed by Results Called by
NVL
NVL
11/6/19 11/7/19
Print Name
Entered By: Emily Schubert
Date: 11/7/2019 Time: 9:04 AM
Special
Jacobs Engineering Group Terracon #81197566
Appendix C Personnel and Laboratory Accreditations
AIHA Laboratory Accreditation Programs, LLC 3141 Fairview Park Drive, Suite 777, Falls Church, VA 22042 USA main +1 703-846-0736 fax +1 703-207-8558
Twitter: @AIHA_LAP_LLC R4 01/24/2018
March 29, 2019
Laboratory ID: 101861
Nghiep Vi Ly NVL Laboratories, Inc.
4708 Aurora Avenue N.
Seattle, WA 98103
Dear Mr./Ms. Ly:
Congratulations! The AIHA Laboratory Accreditation Programs (AIHA- Board (AAB) has approved NVL Laboratories, Inc. as an accredited Industrial Hygiene, Environmental Lead, Environmental Microbiology and Unique Scope laboratory.
Accreditation documentation includes the IHLAP, ELLAP, EMLAP and Unique Scopes accreditation certificate, scope of accreditation document and a copy of the current AIHA-LAP, LLC license agreement (if your completed agreement is not on file at AIHA-LAP, LLC). The accreditation symbol has been designed for use by all AIHA-accreditation, you must complete and return the AIHA-LAP, LLC license agreement to a Laboratory Accreditation Specialist. Once submitted, an electronic copy of the accreditation symbol will be sent to you.
Laboratory accreditation shall be maintained by continued compliance with IHLAP, ELLAP, EMLAP and Unique Scopes requirements (see Policy Modules 2B, 2C, 2D, 2E, and 6), which includes proficient participation in AIHA- LAP, LLC approved proficiency testing, demonstration of competency, or round robin program as indicated on the AIHA- bpage, its associated Scope/PT table, and as required in Policy Module 6, for all Fields of Testing (FoTs) for which the laboratory is accredited. An accredited laboratory that wishes to expand into a new FoT must submit an updated accreditation application to AIHA-LAP, LLC for review by the AAB.
Any changes in ownership, laboratory location, personnel, FoTs/Methods, or significant procedural changes shall be reported to AIHA-LAP, LLC in writing within twenty (20) business days of the change.
The accreditation certificate is the property of AIHA-LAP, LLC and must be returned to us should your laboratory withdraw or be removed from the IHLAP, ELLAP, EMLAP and Unique Scopes.
Again, congratulations. If you have any questions, please contact Lauren Schnack, Laboratory Accreditation Specialist, at (703) 846-0716.
Sincerely, Cheryl O. Morton Managing Director
AIHA Laboratory Accreditation Programs, LLC acknowledges that
NVL Laboratories, Inc.
4708 Aurora Avenue N., Seattle, WA 98103
Laboratory ID: 101861 along with all premises from which key activities are performed, as listed above, has fulfilled the requirements of the AIHA Laboratory Accreditation Programs (AIHA-LAP), LLC accreditation to the ISO/IEC 17025:2017 international standard, General Requirements for the Competence of Testing and Calibration Laboratories in the following:
LABORATORY ACCREDITATION PROGRAMS
INDUSTRIAL HYGIENE Accreditation Expires: June 01, 2021 ENVIRONMENTAL LEAD Accreditation Expires: June 01, 2021 ENVIRONMENTAL MICROBIOLOGY Accreditation Expires: June 01, 2021 FOOD Accreditation Expires:
UNIQUE SCOPES Accreditation Expires: June 01, 2021
Specific Field(s) of Testing (FoT)/Method(s) within each Accreditation Program for which the above named laboratory maintains accreditation is outlined on the attached Scope of Accreditation. Continued accreditation is contingent upon successful on-going compliance with ISO/IEC 17025:2017 and AIHA-LAP, LLC requirements. This certificate is not valid without the attached Scope of Accreditation. Please review the AIHA-LAP, LLC website (www.aihaaccreditedlabs.org) for the most current Scope.
Elizabeth Bair Chairperson, Analytical Accreditation Board
Cheryl O. Morton Managing Director, AIHA Laboratory Accreditation Programs, LLC
Revision 17 09/11/2018 Date Issued: 03/29/2019 for internal methods only) for internal methods only)
| Cover page Terracon Logos |
| Figure 1 bulk sample locations |
| Photodoc |
| Asbestos results |
| Pb results |
| BIR Expires 4.26.2020 |
| NVL AIHA-Industrial-Hygiene exp 2021 |
| 2019-11-25T11:16:58-0800 | |
| Iverson, Jacob F |
| 2019-11-25T11:16:59-0800 | |
| Iverson, Jacob F |
| 2019-11-25T11:44:35-0800 | |
| Parker, Scott R |
| 2019-11-25T11:44:36-0800 | |
| Parker, Scott R |
File details come from the government source that posted it. Updated .