Text version

INITIATED

11/14/17

CED

PRODUCE DEPARTMENT

DEPARTMENT

Minimal Acceptable Standards

REVISION

xx/xx/xx

2P05-A Scale, hanging, produce, 30 pound PAGE 1 of 2

FY16r.05

1 Purpose of this Equipment: To allow patrons the opportunity to estimate the weight of their loose produce before final check out.

2 Federal Supply Class: 6670

3 General Operating Specifications:

3.1 Dimensions:

3.1.1 Scale face: 13 to 16 inch diameter.

3.1.2 Commodity pan: 12 to 18 inch diameter, 3 to 5 inches deep.

3.2 Salient Characteristics that shall be provided:

3.2.1 Hanging scale:

3.2.1.1 Chrome plated steel or stainless steel construction.

3.2.1.2 Scale face enclosed.

3.2.1.3 30 lb. / 15kg capacity.

3.2.1.4 Weight displayed in 1 ounce increments.

3.2.1.5 Dampener system to reduce pointer oscillations.

3.2.1.6 Hanging eye attached to top and bottom of scale housing.

3.2.1.7 Scale face has large easy-to-read numbers.

3.2.2 Commodity pan:

3.2.2.1 Stainless steel.

3.2.2.2 Removable.

3.2.2.3 Steel support bracket for scale attachment.

3.3 Industry Standards / Requirement(s):

3.3.1 Warranty period shall be for (1) year from date of delivery against defective material and workmanship and shall include parts, service and labor.

3.3.2 Meets or exceeds weights and measures H-44, Class III requirements.

3.4 Information Technology requirements: N / A

3.5 Color Requirement(s): N / A

4 Electrical Requirements: N / A

5 Standard Contractor Requirements:

5.1 Must be shipped ready to assemble, mount and use.

INITIATED

11/14/17

CED

PRODUCE DEPARTMENT

DEPARTMENT

Minimal Acceptable Standards

REVISION

xx/xx/xx

2P05-A Scale, hanging, produce, 30 pound PAGE 2 of 2

FY16r.05

5.2 Information to be provided by the Contractor to the commissary at the time of delivery:

5.2.1 Point of Contact for Service

5.2.2 Installation and Operating Instructions

5.2.3 Parts List

5.3 Maintenance Sustainability Requirements: Continued parts support is required for the projected life cycle of the equipment plus 5 years.

6 Special Coordinating / Safety Instructions: N / A

File details come from the government source that posted it.