This document is an amendment to a federal solicitation requesting quotes for a telecommunications circuit. It clarifies technical requirements and provides updated points of contact. Vendors are asked to validate existing quotes or resubmit if prices have changed. The circuit requires 10Gbps Ethernet between buildings at NASA Stennis Space Center, MS and FEMA Mt. Weather, VA. The response date for quotes is May 16, 2022 and the requested service date is October 13, 2022. The amendment specifies interface details, testing requirements, and points of contact at each site. Diversity is required from certain incumbent carriers with presences at the NASA locations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| HC101321QA012-0004.pdf | ||
| HC101321QA012.v0 (1).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 10/22/2020
SUBJECT: HC101321QA012-0001 Amend: 0001
A. TYPE ACTION: ADMIN AMEND
1. PURPOSE: AMENDMENT 0001 IS ISSUED TO CLARIFY PARAGRAPHS 3 & 4 OF PURPOSE
STATEMENT AS FOLLOWS:
3. CURRENTLY, CENTURYLINK/LEVEL-3, AT&T UVN, AND UNITI FIBER/SOUTHERN LIGHT ALL
HAVE A PRESENCE IN BLDG 9357. AT&T LOCAL (LEGACY BELL SOUTH/SOUTH CENTRAL
BELL) MUST BE AVOIDED AND NOT BE USED TO FULFILL THIS INSTALL. THIS IS TO OBTAIN
DIVERSITY FROM CURRENT AT&T CIRCUITS.
4. CENTURYLINK/QWEST, AND UNITI FIBER/SOUTHERN LIGHT ALL HAVE A PRESENCE IN
BLDG 1201. AT&T UVN AND AT&T LOCAL/BELL SOUTH/SOUTH CENTRAL BELL ALSO HAVE A
PRESENCE IN THIS BUILDING BUT MUST BE AVOIDED AND NOT BE USED TO PROVIDE THIS
SERVICE. THIS IS TO OBTAIN DIVERSITY FROM CURRENT AT&T CIRCUITS.
AT FEMA MT WEATHER, ALL TELCO'S AND LECS ARE ACCEPTABLE EXCEPT AT&T.
SUBMIT A QUOTE TO PROVIDE, INSTALL, AND MAINTAIN A 10GB ETHERNET BETWEEN
(BLDG) TELCO DEMARC; (RM) COMM; (FL) 1ST; 19844 BLUERIDGE MT RD, BLUEMONT, VA,
20135/CC3, AND (BLDG) 9357; (RM) 115; 1 FLB; 9357 CYPRESS LOOP ROAD, STENNIS SPACE
CENTER, MS, 39529/CC2.
-SERVICE MUST BE DEDICATED, NON-ROUTED, 10 GBPS, E-PLS PLACED OVER TELCO
OPTICAL MULTIPLEX SYSTEMS/OPTICAL TRANSPORT NETWORK (OTN).
2. CONTRACTOR HAS TWO POSSIBLE INTERFACE DEMARC LOCATIONS FOR STENNIS
SPACE CENTER, MS. THEY ARE:
A. BLDG 9357, ROOM 115, 9357 CYPRESS LOOP ROAD,
STENNIS SPACE CENTER, MS 39529. THIS IS THE PREFERRED DEMARK.
B. BLDG 1201, ROOM 116, C ROAD, 1 STENNIS SPACE
CENTER, STENNIS SPACE CENTER, MS 39529. IF USING THIS DEMARK CONTRACTOR MUST
REHOME TO BLDG 9357 AT NO ADDITIONAL COST WHEN BLDG 1201 IS DEMOLISHED.
3. CONTRACTOR MUST ADDRESS IN QUOTE DIVERSITY & AVOIDANCE FROM CURRENT
VENDORS WITH POINT OF PRESENCE AT BUILDINGS 1201 AND 9357.
HC101321QA012-0001
4. DIVERSITY/AVOIDANCE IS REQUIRED FROM CONTRACTORS WITH POINT OF PRESENCE
AT BUILDING 1201 & 9357.
- CURRENTLY, CENTURYLINK/LEVEL-3, AT&T UVN, AND UNITI FIBER/SOUTHERN LIGHT ALL
HAVE A PRESENCE IN BLDG 9357.
- CURRENTLY, AT&T LOCAL (LEGACY BELL SOUTH/SOUTH CENTRAL BELL), CENTURYLINK/
QWEST, AND UNITI FIBER/SOUTHERN LIGHT ALL HAVE A PRESENCE IN BLDG 1201.
5. CONTRACTORS MUST ADDRESS IN QUOTES COMPLIANCE WITH TESTING AND
ACCEPTANCE REQUIREMENTS WITH “UNDERSTAND AND WILL COMPLY”
6. TESTING & ACCEPTANCE REQUIREMENTS MUST BE COORDINATED WITH GOVERNMENT
POC AT BOTH LOCATIONS BEFORE NOTICE OF COMPLETION IS SUBMITTED TO DITCO.
7. CONTRACTORS ARE RESPONSIBLE FOR READING AND ADDRESSING ALL TECHNICAL
REQUIREMENTS OF THIS INQUIRY/SOLICITATION, READING AND AGREEING WITH THE
STANDARD PROVISIONS, PROVIDE PRICE QUOTATION IN ACCORDANCE WITH STANDARD
PROVISION 4, AND MEET THE REQUESTED SERVICE DATE.
8. THE SERVICE DATE TO BE MET IS: 05 APR 21 (SIP) TO COMPLY WITH PROCUREMENT
ACQUISITION LEAD TIME (PALT) FOR THIS TYPE OF SERVICE.
9. CONTRACTORS MUST CONSIDER ALL ISSUES THAT MAY DELAY THE DELIVERY OF
CIRCUIT ON APPROVED SERVICE DATE. THE GOVERNMENT MAY CANCEL, TERMINATE,
OR REQUEST CONSIDERATION IAW STANDARD PROVISION 42 FOR FAILURE TO MEET
CONTRACTUAL SERVICE.
10. QUOTES MUST INCLUDE NAME AND INFORMATION ABOUT SUB-CONTRACTOR/LONG
HAUL PROVIDER/OTHER CARRIER INSTALLING CIRCUIT IS ON NET/OFF NET, RTD, JUMBO
FRAMING, TESTING AND OTHER APPLICABLE TECHNICAL INFORMATION. FURTHERMORE,
IF A BUILD IS REQUIRED TO INSTALL, VENDOR MUST INDICATE THE SCOPE OF THE BUILD
(LENGTH, BURIED/AERIAL, TRENCHING/DIRECTIONAL BORING, NEW CONDUIT, ETC.)
VENDOR MUST ALSO INDICATE IF SITE POC (S) HAVE ADVISED THAT PERMISSION FOR
BUILD AT SITE (S) WILL BE GRANTED, AND IF SITE (S) HAVE SUFFICIENT SPACE, POWER
AND HVAC CAPACITY TO SUPPORT VENDOR EQUIPMENT AND CABLING. MAPS/BLOCK
DIAGRAMS ARE AN ACCEPTABLE WAY TO PROVIDE THIS INFORMATION.
11. QUOTES MUST BE UPLOADED TO IDEAS. THE GOVERNMENT IS NOT RESPONSIBLE
FOR MISSING OR OVERLOOKED QUOTES. CONTRACTORS ARE INSTRUCTED TO SUBMIT
QUESTIONS AND REQUEST CLARIFICATIONS OF REQUIREMENT (S) BEFORE SUBMITTING
QUOTES. IN RESPONSE TO THIS SOLICITATION, NO TERMS OR CONDITIONS PLACED UPON
THE GOVERNMENT, NOR ASSUMPTIONS WILL BE ACCEPTED.
12. PRE AWARD SITE SURVEYS ARE AUTHORIZED (AT CONTRACTOR EXPENSE) AND
SHOULD BE CONDUCTED IN COORDINATION WITH LOCAL POCS AT EACH GOVERNMENT
SITE.
13. ESTABLISH TSP: TSP0KL06N-02
14. CIRCUIT SPECIFICATIONS:
TELCO INTERFACE AT STENNIS SPACE CENTER FACILITY WILL BE SINGLE MODE FIBER,
8.5/125 MICRON, WITH OPTICS WORKING AT 1300NM.
VENDOR MUST PROVIDE LIGHT LEVEL READINGS (DB LOSS) AT THE DEMARC LOCATIONS
PRIOR TO CIRCUIT TURN UP TO THE GOV'T INSURING THE LIGHT LEVELS ARE WITHIN
SPECS. LIGHT LEVELS MUST BE ADJUSTED TO -5 TO -13.
THE GOVERNMENT WILL EXTEND THE SERVICE FROM THE STENNIS TELCO DEMARCS TO
THE DHS END USER FACILITIES USING NASA INSTALLATION FIBER.
NASA INSTALLATION POCS FOR TELCO DEMARC AT BLDGS 9357 OR 1201, RM 115/116 ARE;
A. MR. PHILIP GERACI OFFICE PHONE: 228-688-1315 CELL PHONE: 228-363-5141 E-MAIL:
PHILIP.A.GERACI@NASA.GOV B. MR MARK ASHLEY OFFICE PHONE: 228-688-1986 E-MAIL:
MARK.ASHLEY-1@NASA.GOV C. MR AARON P. LUNT OFFICE PHONE: 228-688-1314 CELL
PHONE: 228-596-9216 E-MAIL: AARON.P.LUNT@NASA.GOV .
TELCO HAS MULTIPLE POSSIBLE DEMARC LOCATIONS AT THE FEMA FACILITIES FOR MT
WEATHER, BLUEMONT, VA. THE AT&T FACILITIES SHOULD NOT BE USED IN ORDER TO
DIVERSE THIS CIRCUIT FROM THE AT&T 10 GBPS MPLS CIRCUIT BEING DELIVERED UNDER
DITCO GSA EIS CONTRACT AWARD FOR MPLS SERVICE FOR DHS. ALL OTHER TELCO
AND LEC FACILITIES ARE ACCEPTABLE FOR THIS SERVICE DELIVERY. WINNING TELCO
MUST DELIVER SERVICE TO THEIR OR THEIR SUPPORTING TELCO LECS POP AND NOTIFY
AND SHOW SITE PERSONNEL LISTED IN THIS ORDER THE LOCATION OF THE CIRCUIT,
AND TAG WITH BOTH THE LONG HAUL AND LEC CIRCUIT IDENTIFIERS. THE MT WEATHER
PERSONNEL WILL THEN EXTEND THE CIRCUIT FROM THE TELCO DEMARC TO THE DHS
SITE EQUIPMENT USING SITE SINGLE MODE FIBER.
TELCO INTERFACE AT FEMA MT WEATHER FACILITY WILL BE SINGLE MODE FIBER, 8.5/125
MICRON, WITH OPTICS WORKING AT 1300NM.
VENDOR MUST PROVIDE LIGHT LEVEL READINGS (DB LOSS) AT THE DEMARC LOCATIONS
PRIOR TO CIRCUIT TURN UP TO THE GOV'T INSURING THE LIGHT LEVELS ARE WITHIN
SPECS. LIGHT LEVELS MUST BE ADJUSTED TO -5 TO -13.
THE GOVERNMENT WILL EXTEND THE SERVICE FROM THE MT WEATHER TELCO DEMARCS
TO THE DHS END USER FACILITIES USING GOV'T FIBER.
FEMA INSTALLATION INFRASTRUCTURE POCS FOR TELCO DEMARC AT MT WEATHER ARE;
A. MR. TIMOTHY RABER OFFICE PHONE: 540-542-2112 CELL PHONE: 202-762-1994 E-MAIL:
TIMOTHY.RABER.2@FEMA.DHS.GOV B. MR TED COMEAU OFFICE PHONE: 540-542-7663 E-
MAIL: TED.COMEAU@FEMA.DHS.GOV C. MR JAMES COE OFFICE PHONE: 540-542-4200 E-
MAIL: JAMES.COE@CISA.DHS.GOV D. MR DAVID SHANHOLTZ OFFICE PHONE: 540-542-4242
E-MAIL: DAVID.SHANHOLTZ@CISA.DHS.GOV .
CIRCUIT MUST BE TAGGED WITH LOCAL EXCHANGE CARRIER (LEC) CIRCUIT ID AND LONG
HAUL CARRIER ID AT BOTH SERVICE LOCATIONS.
CIRCUIT REQUIRES THE FOLLOWING TECHNICAL PARAMETERS:
A. DATA RATE: 10.0 GBPS PLUS OR MINUS 20 PPM
B. FORMAT: ETHERNET 802.3AW
C. FRAMING: ETHERNET 802.3AW
D. ELECTRICAL INTERFACE: OPTICAL, SINGLE MODE, 1310 NM
E. IEEE STANDARD: 802.3AW COMPLIANT
F. LINE MUST REMAIN OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY, SEVEN
DAYS PER WEEK, AT LEAST 99.5% OR BETTER.
G. REQUEST ONE-HOUR RESPONSE TIME TURN-AROUND TO REPAIR ONCE TROUBLE CALL
HAS BEEN REPORTED.
H. GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED INTO THE
CIRCUIT.
I. SINGLE MODE FIBER TERMINATIONS: SC OR LC
J. NO NETWORK INTERFACE UNIT (NIU).
FAILURE TO READ AND ADDRESS ANY OF THE TECHNICAL REQUIREMENTS AND SERVICE
DATE REQUESTED IN THIS INQUIRY SHALL RENDER THE QUOTE NON-COMPLIANT AND
RESULT IN IT BEING EXCLUDED FROM EVALUATION AND AWARD.
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: HL19AUG205072
4. CCSD: VUED7CLQ